In der Ausgabe 6/2012 der Zentralsterilisation wurde die Empfehlung 77, das überarbeitete Flussdiagramm der DGSV zur Einstufung

Similar documents
Hygienic Reprocessing

inspection body type A

Manufacturer s information

Validation of manual cleaning and disinfection procedures

How clean are your instruments?

Scope of Accreditation of Testing Laboratory (EN ISO/IEC 17025:2005) HygCen Austria GmbH / (ID No.: 0196)

Endoscopic Technology. Operating Manual. Cannula system

Preparation Instructions for the CAMLOG /CONELOG Implant System

INSTRUCTIONS FOR CLEANING, DISINFECTION AND STERILIZATION OF DFS INSTRUMENTS

Reprocessing of dental instruments and angle handpieces

AMENDATORY SECTION (Amending WSR , filed 10/10/95, effective 11/10/95)

Disinfection and Decontamination Core Subject. The Process of Instrument Decontamination

Peninsula Dental Social Enterprise (PDSE)

Velocity Orthopedics Instrument Cleaning and Sterilization

Reprocessing Guide. Autoclavable Arthroscope and Hardware Sterilization Tray

Scope This policy applies to all personnel and departments that clean, prepare and/or sterilize items intended for patient care use.

DIRECTIVES. (Text with EEA relevance)

Recommendations for cleaning, disinfection and sterilization of orthopaedic instruments and devices from Swemac.

Non-destructive testing Penetrant testing. Part 2: Testing of penetrant materials

Sample Enhanced Visual Inspection of medical devices. SUBJECT: Enhanced Visual Inspection of medical devices

Complex Medical Devices and Steam Sterilization. By Andrew Gay Director - Sterilizer Validation Australia


ASTM Workshop on Medical Device Cleanliness

Infection Control. Dr. Kannan Rengasamy School of Dental Medicine University of Connecticut. ADAA guide module VIII

M6-C Artificial Cervical Disc Surgical Instruments

Workshop on the reprocessing of medical devices. 5. December Brussels. Nikou Ghassemieh Managing Director

INFECTION PREVENTION AND CONTROL POLICY AND PROCEDURES Sussex Partnership NHS Foundation Trust (The Trust)

AMENDATORY SECTION (Amending WSR , filed 10/10/95, effective. WAC Purpose. The purpose of WAC through

The reprocessing of medical devices in Dentistry. Are there any differences to the reprocessing of surgical instruments?

Animal health requirements for heat-processed poultry meat and meat products. to be exported from Russian Federation to Japan.

ÜBERCLEAN! Introducing the new STATMATIC PLUS.

Table of Contents. Introduction Indications For Use Contraindications Warnings Precautions...5

COMMITTEE FOR MEDICINAL PRODUCTS FOR VETERINARY USE (CVMP) GUIDELINE ON USER SAFETY FOR IMMUNOLOGICAL VETERINARY MEDICINAL PRODUCTS

Single market, regulatory environment, industries under vertical legislation Pharmaceuticals : regulatory framework and market authorisations

Food additives. FAO guidelines on the structure and content of the document called "Chemical and Technical Assessment (CTA)" Rome, February 2003

INSTRUCTIONS FOR USE AND CARE

Single Use Curlew TM Multiple Biopsy Forceps

247 CMR BOARD OF REGISTRATION IN PHARMACY

The Food and Drug Administration (FDA) is providing a detailed list of supplemental duodenoscope reprocessing measures that emerged from an agency-led

Yasargil Permanent Aneurysm Clips

+ Agenda Items 2, 3 and 4 CRD 14 JOINT FAO/WHO FOOD STANDARDS PROGRAMME

ISO INTERNATIONAL STANDARD. Non-destructive testing Penetrant testing Part 1: General principles

book Seite 1 Freitag, 21. April : fjmi^kq=omwn. Operating instructions. båöäáëü. lééê~íáåö=fåëíêìåíáçåë

IPEC Europe Suggested Alternative (if none then original text is clear and needs no alteration) Purpose and Scope

Altus Product description / Instructions for Use IFU 6 Rev. 1

Annex IV(k) DRAFT EAST AFRICAN STANDARD

Implementation Guide for the DoseControl Dosimetry System

Aesculap Spine Instructions for use

Appendix C. RECOMMENDATIONS FOR INFECTION CONTROL IN THE HEALTHCARE SETTING

PPG Single Use Medical Devices

The authorisation of plant protection products for non-professional users and for use in home gardening

Key Words cleaning validation

Test-Report No.:

Withdrawn at December 31, Guideline DKD-R 6-2. Calibration of Measuring Devices for Vacuum DEUTSCHER KALIBRIERDIENST. Part 1.

Employee Health and Personal Hygiene. for SCHOOL NUTRITION STAFF

INFECTION CONTROL IN PRACTICE. Continuing Education

Provläsningsexemplar / Preview INTERNATIONAL STANDARD. Rubber condoms - Part 1: Requirements

Instruments and accessories. for vessel sealing VESSEL SEALING

Massage to support. Postnatal 11/11/2014. Infection Control 2013 in your Massage Practice. Monica Pasinato-Forchielli

Straumann ProClean Cassette. Basic Information on the

SAFETY DATA SHEET. SECTION 1: Identification of the substance / mixture and of the company / undertaking.

Excipient Risk Assessment

CRITERIA AND PROCEDURE PURPOSE OF THIS CRITERIA/PROCEDURE

Aesculap Implant Systems

Prepared by Wake County Environmental Services, Environmental Health & Safety Division

Respiratory Protection for Exposures to the Swine Influenza A (H1N1) Virus: Health Care Workers

Instructions for use 0483 Permanent and temporary YASARGIL Aneurysm and Vessel Clips

This document is a preview generated by EVS

BS EN ISO 14971: Risk Analysis and Risk Management Report

ProUltra ULTRASONIC SURGICAL TIPS

UNOFFICIAL TRANSLATION

Dear Marie Consultation on a proposed Infection Prevention and Control Practice Standard

Achieving Effective and Reliable NDT in the Context of RBI

Orientation Program for Infection Control Professionals. Module 9: Cleaning, Disinfection, and Sterilization of Medical Equipment and Devices

CLEANING EFFICIENCY OF PRE-STERILIZATION PROTOCOLS FOR REUSABLE DENTAL BURS

TONTARRA Medizintechnik GmbH. Surgical Instruments in Demand. Laminectomy Punches and Rongeurs

Protection 4U NEW GENERATION

This document is a preview generated by EVS

Lakshy Management Consultant Pvt. Ltd.

DTSS Practice Inspections

For: Infection Control, Operating Room, Endoscopy and Reprocessing Staff, Risk Managers, et al. Volume 12, Numbers 11, 12 November-December 2006

M Manufacturer by: Guide for Cleaning, Sterilization and Storage of Instruments for Caldera Medical Desara Product Family of Implants

THE. Curve THE CURVE STRIPPING TOOL

Draft Guidance for Industry and FDA Staff

CURVES. Anatomically Adaptable IPR strips. Brochure Instructions for use Processing instructions

Introduction. Doc-Biocides-2002/01 Version

State of California Health and Human Services Agency Department of Health Services. April 30, 2007 AFL 07-09

Cleaning and sterilization instructions for Astra Tech Implant System EV

Sterile hypodermic needles for single use Requirements and test methods

ProUltra Ultrasonic Non Surgical Endo Tips

UK National Aerospace NDT Board

Healthcare Sterilisation: Challenging Practices Volume 2

Version No.: 5.0 TITLE: SDS FOR FECAL OCCULT BLOOD TEST KIT T1-CK SERIES Page 1 of 5

KEY DIFFERENCES BETWEEN THE NEW MEDICAL DEVICE AND THE OTC REGULATIONS IN EUROPE

BS EN ISO 14971: Risk Analysis and Risk Management Report

INFORMATION TO THE PRODUCT RANGES. Instructions for Cleaning, Disinfection, Sterilization, Inspection and Maintenance of Medartis Products APTUS MODUS

MVKOMNT. kéï=~ë=çñw= bkal=swn. lééê~íáåö=fåëíêìåíáçåë. båöäáëü. Operating Instructions

Module 34: Legal aspects, ADI and GRAS status of food additives

Transcription:

64 DGSV Zentralsterilisation 1/2013 twendige Korrektur des Flussdiagramms der DGSV 2012 im Januar 2013 In der Ausgabe 6/2012 der Zentralsterilisation wurde die Empfehlung 77, das überarbeitete Flussdiagramm der DGSV zur Einstufung von Medizinprodukten, veröffentlicht. Zum großen Bedauern der Verfasser wurde im Flussdiagramm an einigen Stellen unklar formuliert. Dadurch kann es zu Diskussionen, insbesondere zum Thema «Validierte Verfahren» kommen. Deshalb wurden Korrekturen vorgenommen, und das Flussdiagramm wird erneut mit der Überschrift «Flussdiagramm der DGSV zur Einstufung von Medizinprodukten 2013» veröffentlicht. In der Überarbeitung wurde der Begriff «validiert» aus dem Flussdiagramm gestrichen und stattdessen wurde auf dem Merkblatt «Ergänzende Informationen zum Flussdiagramm zur Einstufung 2012» ein weiterer Merksatz zu «Geeigneten validierten Verfahren» vorangestellt. Wir bitten alle Leser der Zentralsterilisation und alle Besucher der Webseiten, die Empfehlung aus der Zentralsterilisation Heft 6/ 2012 durch die aus der Ausgabe 1/2013 zu ersetzen. Correction Needed to DGSV Flow Chart 2012 in January 2013 In Issue 6/2012 of Central Service, Recommendation 77, the revised version of the DGSV flow chart for classification of s, was published. The authors very much regret that the wording used in certain sections was unclear. That gave rise to discussions, in particular on the topic of «validated processes». Therefore corrections have been made and the flow chart is being published again under the title «DGSV Flow Chart 2013 for Classification of Medical Devices». The term «validated» has been deleted from the flow chart and instead an additional key sentence on «Suitable validated processes» has been added to the instructions sheet. We ask all readers of Central Service and all website visitors to replace the Recommendation from Issue 6/2012 with that from Issue 1/2013.

Central Service 1/2013 recommendations 69 Recommendations by the Quality Task Group (77 Revised Version) DGSV Flow Chart 2013 for Classification of Medical Devices With the publication of the recommendation by the Commission for Hospital Hygiene and Infection Prevention (KRINKO) at the Robert Koch Institute (RKI) and the Federal Institute for Drugs and Medical Devices (BfArM) on the hygiene governing the reprocessing of s (KRINKO/BfArM Recommendation) in the Federal Health Gazette 2012; 55:1244 1310 it became necessary to revise the flow chart compiled by the German Society of Sterile Supply (DGSV) for classification of s. During the revision process it was noted that certain parts of the flow chart had to be explained and that a supplement should be provided in addition to the diagram in order to establish a direct link to some of the citations from the KRINKO/BfArM Recommendation. Apart from comments explaining certain points, this Recommendation does not constitute a statement of opinion by the Quality Task Group of the DGSV e. V. on the contents of the KRINKO/BfArM Recommendation. The flow chart and instructions sheet are intended as a means of making it easier for users/reprocessing personnel to classify medical devices before reprocessing. The use for which s are intended is specified in the manufacturer s instructions (e. g. minimally invasive surgery [MIS] instruments, cystoscopes, hysteroscopes, spinal cord instruments, ear, nose and throat [ENT] instruments, eye instruments, endoprosthetic instruments). Hence how a is to be used is always a basic prerequisite to be borne in mind for risk assessment and classification. That means that a device can be properly classified only after consulting users, or the person responsible for classification has the necessary knowledge of the intended use thanks to his aptitude/qualification and expertise. Only in this way can the circuit function and proper reprocessing be assured. The publication was agreed in advance with representatives of the RKI and a link to it is given on the RKI website. The DGSV Quality Task Group hopes that this revised flow chart, too, will prove to be a useful recommendation for classification of s. It replaces Recommendations 22, 23 and 24 on classification of s prior to reprocessing (Parts 1 3) published in 2002, Recommendation 31, update of decision-making tree on risk assessment and classification of s published in Issue 6/2003 as well as the publication that was compiled in 2008 in A3 format together with DIOS. Instructions; sheet «Supplementary information on the Flow Chart 2012 for classification of medical devices» Suitable validated processes Page 1265, Annex 1: «For decontamination of a, the sum of all the automated and manual processes involved (individual decontamination steps that complement each other) contribute to reaching the respective decontamination goal. Hence, inadequately validated individual steps (processes) detract from the quality of the decontamination results in equal measure as the failure to observe standard operating instructions.» Page 1250, 1.3 Validation of decontamination processes: «When choosing cleaning and disinfection processes, priority must be given to automated processes that can be validated. Manual cleaning and disinfection processes, which for example are used to preclean s or to clean/disinfect those s not amenable to automated decontamination (group B) or which are employed on the basis of risk analysis, must always be carried out in accordance with standard operating procedures, using products and processes whose effectiveness and compatibility with the respective has been verified (i. e. which are suitable and compatible with the respective material).» As such, all individual steps, both manual and automated steps, must be taken into account when validating the decontamination process. (*1) Manufacturer s instructions for reprocessing Page 1250, 1.2.2 Manufacturer s instructions: «The marketability of a classified by the manufacturer for reuse implies that the manufacturer is obliged to provide instructions for reprocessing, including for cleaning, disinfection, rinsing, drying and, if applicable, for packing and sterilization, transport as well as proper storage and, if applicable, also regarding the risks associated with reprocessing» «If there is any deviation from the manufacturer s reprocessing instructions, the reason for this must be explained and documented, while ensuring that the functional capability, as specified by the intended use, and the application safety of the reprocessed (decontaminated) are fully preserved (see also 1.2.1). Appropriate testing and validation of processes, which take account of the and its risk assessment and classification, must be carried out to ascertain their suitability and effectiveness in collaboration with infection control (hygiene) personnel.» This entails extensive testing, in particular for critical s, which is generally beyond the scope of a reprocessing unit (reprocessing centre). At this juncture, it is also advisable and/or necessary to decide against reprocessing of the.

70 Recommendations Central Service 1/2013 (*2) Expert personnel Page 1276, Annex 6, Expertise of personnel: «Requirements regarding the expertise of personnel entrusted with reprocessing in Category A and B reprocessing units» (see Annex 5) Page 1275, Annex 5, Overview of addressed to s reprocessing units: Category A, B and C reprocessing units with regard to classification of the s to be decontaminated Reprocessing Unit A = Semi-critical A, critical A Reprocessing Unit B = Semi-critical B, critical B Reprocessing Unit C = Critical C (includes A and B) (*3) «Blood products» are not mentioned in Flow Chart 2012 Page 1247, 1.2.1 Risk assessment and classification of s before reprocessing: «Medical devices for application of blood, blood products or other sterile drugs/sterile s» are critical s and must be classified and decontaminated according to the information provided in the flow chart. (*4) Precleaning With regard to reprocessing after use, the following point must be noted: Page 1252, 2.2.1 Preparations for reprocessing (pretreatment, collection, precleaning, if applicable, dismantling, intermediate storage and transport): «To avoid compromising the hygienic state and the functionality of the decontaminated, in particular if there are any delays before cleaning and disinfection, precleaning and, possibly, intermediate storage is needed and must meet the following : Coarse soils should be removed from the immediately after use. Every effort must be made to identify suitable methods and procedures to prevent blood and tissue from drying onto the (e.g. by wiping off external soils and rinsing working channels immediately after use; devising a schedule to collect instruments after use), and especially to avoid any negative impact on the cleaning performance (drying of pathogens in protective colloids)» Standard operating procedures (SOPs) must be compiled as part of the quality management system for those process steps conducted outside the reprocessing unit. These must be jointly drafted by users and reprocessing personnel. (*5) Protective packaging for disinfected devices Page 1256, 2.2.6 Labelling: «In the case of s for which reprocessing ends with disinfection, the user must also be able to recognize that the process has been executed (QM).» Page 1258, 3 Transport and storage: «(Semi-critical) s harbouring only a low microbial count must be stored such that recontamination is avoided during storage» Packing and labelling are implemented using appropriate protective packaging in the clean zone of the reprocessing unit, while avoiding recontamination, in a dry state and with personnel wearing gloves that harbour at most only a low microbial count. (*6) Wording «cavities or parts that are difficult to access» In the flow chart the wording «cavities or parts that are difficult to access» was retained to make this easier to understand. The wording in the KRINKO/BfArM Recommendation is as follows. Page 1248, 1.2.1 Risk assessment and classification of s before reprocessing: The aforementioned wording «cavities or parts that are difficult to access» is understood to mean those s for which «the effectiveness of cleaning cannot be assessed through visual inspection (e. g. because of long, narrow, and especially lumens closed at one end, cavities with only one opening [purging is not possible, only dilution], surfaces that are complex, rough or poorly accessible and therefore difficult to clean).» (*7)Disinfection A 0 value Page 1254, 2.2.2 Cleaning, disinfection, rinsing and drying: «Preference must be given to thermal processes in washer-disinfectors because of their superior reliability (e. g. less risk of residual contamination) over chemical or chemothermal processes.» For the A 0 value concept please refer to EN ISO 15883-1 and to the Guideline for validation and routine monitoring of automated cleaning and thermal disinfection processes for s and for selecting washer-disinfectors, Annex 7: The A 0 concept of EN ISO 15883. (*8) Certification reprocessing of category Critical C s Page 1247, 1.2.1 Risk assessment and classification of s before reprocessing and Page 1251, 1.4 Safeguarding the quality of the reprocessing processes used: «Reprocessing of s subject to ultra stringent reprocessing («critical C», see. Table 1) shall be certified pursuant to EN 13485 by a body accredited by the competent authority in conjunction with their «Hygiene for reprocessing of s» (QM). External certification is not required if the manufacturer of the has specified concrete instructions for using another special sterilization process and the application of that process has been validated in situ in terms of its effectiveness.» The expression «another special sterilization process» means a process other than moist heat sterilization. Reprocessing of «non-s» Foodstuffs utensils, e. g. baby bottles, pacifiers, drinking cups, etc. are generally not s and are not subject to classification as per the KRINKO/BfArM Recommendation. They are decontaminated in accordance with other guidelines or/and recommendations of specialist societies.

Central Service 1/2013 Recommendations 71 DGSV Flow Chart 2013 for Classification of Medical Devices Medical Device Reprocessing while taking account of the manufacturer s instructions (*1) by personnel of proven expertise (*2) Contact with only intact skin? Contact with mucosa or pathologically altered skin? Penetration of skin or mucosa (*3) n-critical Semi-critical Critical Cleaning/disinfection Are there cavities or parts that are difficult to access? (*6) and/or Are there reprocessing effects impacting on the function and safety of the MD? and/or Is the number of reprocessing cycles limited? See page 2 Semi-critical A particular reprocessing Semi-critical B Stringent reprocessing apply n-fixing precleaning if needed (*4) n-fixing precleaning immediately after use *4) Preferably automated cleaning (preferably alkaline) and thermal disinfection Chemical disinfectants/ processes must be bactericidal, fungicidal and virucidal (DVV/RKI guideline) Preferably automated cleaning (preferably alkaline) and thermal disinfection Testing technical/functional safety Testing technical/functional safety Should the MD be sterile when used? Should the MD be sterile when used or inserted into a sterile body compartment? Packaging (protection against recontamination/ dust protection [*5]) Packaging (sterile barrier system and, if. app., protective packaging) Packaging (protection against recontamination/ dust protection [*5]) Packaging (sterile barrier system and, if. app., protective packaging) Sterilization in principle Sterilization in principle Label «disinfected» Label «disinfected» Compiled on the basis of the KRINKO/BfArM Recommendation for «Hygiene for reprocessing of s» Federal Health Gazette 2012; 55: 1244 1310 Copyright by Quality Task Group January 2013

72 Recommendations Central Service 1/2013 Critical Are there cavities or parts that are difficult to access? (*6) and/or Are there reprocessing effects impacting on the function and safety of the MD? and/or Is the number of reprocessing cycles limited? Critical C with ultra stringent reprocessing n-fixing precleaning immediately after use (*4) Critical A particular reprocessing Critical B Stringent reprocessing apply Are there manufacturer s instructions for a validated low-temperature (LT) sterilization process? n-fixing precleaning if needed (*4) Preferably automated cleaning (preferably alkaline) and Steam sterilization possible? n-fixing precleaning immediately after use (*4) Further reprocessing: only in establishments with externally certified quality management system as per EN ISO 13485 in conjunction with the KRINKO/BfArM Recommendation (*8) In principle automated cleaning preferably alkaline, In principle automated cleaning preferably alkaline, Sterilization in principle Sterilization LT sterilization process specified by MD manufacturer and validated in the reprocessing unit Suitable LT sterilization process Compiled on the basis of the KRINKO/BfArM Recommendation for «Hygiene for reprocessing of s» Federal Health Gazette 2012; 55: 1244 1310 Copyright by Quality Task Group January 2013