Bands and Attachments

Similar documents
Table of Contents Section 6 Table of Contents

THE MBT VERSATILE+ APPLIANCE SYSTEM

Victory Series Buccal Tubes Designed for Comfort and Performance. Advanced, Precise. Solutions. for Molars

Bands Buccal Tubes Lingual Attachments. When only the best will do.

System Orthodontic Treatment Program By Dr. Richard McLaughlin, Dr. John Bennett and Dr. Hugo Trevisi

The Rondeau System. Brackets, Bands, Buccal Tubes and Archwires. Orthodontic supplies recommended by Dr. Brock Rondeau

TUBES, LINGUAL ATTACHMENTS AND BANDS. tportho.com cosmeticbraces.com. POD_TPOC_04_Tubes_Linguals_Bands_2017, Rev. 1

Delta Force. Bracket System. Putting you in the driver s seat for ultimate control

Victory Series Active Self-Ligating Brackets. Reliable. and. Effective

Archwire Insertion and Disengagement Instruments Technique Guide

Bracket Systems. A good bracket is the foundation of a good treatment plan... Go ahead, choose the best. Metal Bracket.

Space Closure Biomechanics Applied Using The MBT System Technique

Advantages. Fantastic. Treatment. Finishes. 3M Self-Ligating Appliances Lateral Development System. Unitek Lateral Development Archwires

INDICATIONS. Fixed Appliances are indicated when precise tooth movements are required

With judicious treatment planning, the clinical

TURN CLASS II INTO SIMPLE CLASS I PATIENTS.

rocky mountain orthodontics functionaleducation

TOL

Introducing the Clarity SL Self-Ligating Appliance System

Advantages. Fantastic. systems. Together with Unitek Lateral Development Archwires, this system puts you in control to

3M Incognito Appliance System extraction case study.

Clarity. Form meets function: Discover the science behind a versatile self-ligating bracket system. Aesthetic Orthodontic Solutions

MAESTRO Low-Profile Bracket System. Discover the precision, comfort, and control of the MIM-Manufactured Maestro Bracket

3D CONTROL HAS ARRIVED

Clarity. Esthetic Orthodontic Solutions. 3M Clarity Ultra Self-Ligating Brackets Practice confidently. Smile beautifully.

Table of Contents Section 1 Table of Contents

ORTHODONTIC BANDING AND CEMENTATION. Materials

SmartForce features and Attachments. Designed to help you treat with confidence.

Outline the significance of the pre-adjusted Edgewise appliance system and useful bracket variations in orthodontics

BUCCAL TUBES & MOLAR BANDS

Table of Contents Section 12 Table of Contents

PRE-FINISHER APPLIANCE AND BONDABLE LINGUAL RETAINERS. tportho.com cosmeticbraces.com. POD_TPOC_09_PreFinisher_Retainers_2015, Rev.

BUCCAL TUBES & MOLAR BANDS

SnapLink Re-Convertible Tube

Orthodontic Product Catalog

Great Smiles Begin With

From Plan B to Plan A : Using Forsus Class II Correctors as a Regular Mode of Treatment

The management of impacted

A THESIS SUBMITTED TO THE FACULTY OF THE GRADUATE SCHOOL OF THE UNIVERSITY OF MINNESOTA BY

The 20/20 Molar Tube. Ronald M. Roncone, D.D.S., M.S.

Plus Combines Traditional Twin Bracket Treatment With Self-Ligation Convenience

Crowding and protrusion treated by unusual extractions

MemRx Orthodontic Appliances

TURN CLASS II INTO SIMPLE CLASS I PATIENTS.

BOCL-01: Bonding Materials Checklist

Table of Contents Section 7 Table of Contents

We Give Back. Reduce Emergency Visits! ATTACHMENTS. No More Poking Archwires! Crimpable Mini Stops. Tooth Tone Crimpable Mini Stops

essentialstm cutting your consumable costs brackets tubes wires springs instruments T:

6. Timing for orthodontic force

Bicuspid Cuspid Maxillary Brackets. Bicuspid Central Cuspid Lateral... 84

Expansion/Arch Development

Downloaded from by guest on 15 November 2018

MBT System as the 3rd Generation Programmed and Preadjusted Appliance System (PPAS) by Masatada Koga, D.D.S., Ph.D

Forsus Class II Correctors as an Effective and Efficient Form of Anchorage in Extraction Cases

INDEX. Zeusan Exporting Ltd 2/14. Product page

INTRAORAL / EXTRAORAL. tportho.com cosmeticbraces.com. POD_TPOC_06_Intraoral_Extraoral_2017, Rev. 1

Interdisciplinary management of Impacted teeth in an adult with Orthodontics & Free Gingival graft : A Case Report

Dental Morphology and Vocabulary

Orthodontic Treatment Using The Dental VTO And MBT System

Seminar 5 Expectations

Enhanced Control in the Transverse Dimension using the Unitek MIA Quad Helix System by Dr. Sven G. Wiezorek

Aesthetic Brackets and Accessories

Annex II (excluding section 4) of Council Directive 93/42/EEC concerning medical devices

The Tip-Edge appliance and

The Tip-Edge Concept: Eliminating Unnecessary Anchorage Strain

Honing Damon System Mechanics for the Ultimate in Efficiency and Excellence Jeff Kozlowski, DDS East Lyme, CT

Brackets

< > INVISALIGN OUTCOME SIMULATOR QUICK REFERENCE GUIDE. Home Contents Overview Important Notes. STEP 1 Scan Patient s Teeth Submit Scan

Dual Force Cuspid Retractor

Table of Contents Section 11 Table of Contents

Simply Great Wire! Great prices.

Class I. Clear Fixed Appliance vs. Aligner Treatment for Arch Development. Clinician: Dr. Stuart Frost, Phoenix, AZ Patient: A.M.

Fixed Twin Blocks. Guidelines for case selection are similar to those for removable Twin Block appliances.

LINGUAL STRAIGHTWIRE BRACKET SYSTEM Designed with Drs. Kyoto Takemoto and Giuseppe Scuzzo

Flip-Lock HERBST Appliance COMFORT. CUSTOMIZATION. ADVANCED ENGINEERING.

Quality. Elegance. Innovation.

Study Model-based Evaluation of Built-in Tip, Torque, and In out Characteristics of a Third-generation Preadjusted Edgewise Appliance

Experience with Contemporary Tip-Edge plus Technique A Case Report.

Ortho Specialties. UniCoat Aesthetic Archwires MidTherm. Grabber. Enhance Ceramic. S.E.T. Super Elastic Torqued Anterior Pretorqued Archwires

Lab Forms and Communications Precise Indirect Bonding Systems.

Passive friction active control

INCLUDES: OVERVIEW ON CLINICAL SITUATIONS FREQUENTLY ENCOUNTERED IN ORTHODONTIC TREATMENTS MECHANOTHERAPY USED TO RESOLVE THESE SITUATIONS

Gentle-Jumper- Non-compliance Class II corrector

Virtual Treatment Planning

The Ultimate in Crystal Clear Aesthetics

Advancing the Art of Freehand Cosmetic Contouring

Class II. Bilateral Cleft Lip and Palate. Clinician: Dr. Mike Mayhew, Boone, NC Patient: R.S. Cleft Lip and Palate.

Protocol for itero and ioc

ALL STAR ORTHODONTICS

The Science Behind The System Clinical Abstracts, Volume 2

(12) Patent Application Publication (10) Pub. No.: US 2012/ A1

Dental Data Checklist. UNIDENTIFIED PERSON FILE Data Collection Entry Guide. City, State, and ZIP. Street Address. FAX Number.

CLINICAL CONSIDERATIONS CROWDING

The FARRELL BENT WIRE System

Bracket Cutter Orthodontic Pliers Wire Cutter Ligature Instrument Bonding Instrument Orthodontic Articulator Measuring Device Torch Locking Tweezers

EUROPEAN SOCIETY OF LINGUAL ORTHODONTISTS

CLEAR COLLECTION FOR CLEAR ALIGNERS CLEAR SOLUTIONS FOR CUSTOMIZED EFFICIENCY

ch00-m3395-plims 8/3/07 21:29 Page i SmartClip TM Self-Ligating appliance System

Anterior tooth morphology and its effect on torque

Transcription:

RxWeld Service Custom Services Convenient prescription program for orthodontists who reorder 3M Unitek seamless bands prewelded with 3M Unitek attachments Reduces reorder time and paperwork Eliminates order confusion and reduces potential prewelding errors Reordering bands prewelded with correct attachments and precise angulation and positioning is a time-consuming task in any orthodontic practice. 3M Unitek offers a unique ordering service which greatly simplifies band reordering. Here s how it works: Every orthodontist ordering prewelded bands from 3M Unitek has a prescription on file, containing customized ordering instructions. Reorders with instructions that deviate from the prescription file will be verified by phone before 3M Unitek processes the order. Custom order forms and a copy of your prescription are available on request. Standard Welding 3M Unitek attachments in standard positions (see standard positions chart for edgewise and light wire attachments) on 3M Unitek seamless bands and bonding bases. No charge. Custom Welding 3M Unitek attachments in non-standard positions (see angulation chart for details on custom angulation) on 3M Unitek seamless bands and bonding bases. No charge. Tack-welding only 3M Unitek attachments to 3M Unitek seamless bands. No charge.

Torqued Attachments Standard Angulation Chart Angulation direction is illustrated by chart. Chart is shown as if viewer is facing patient. Degree of angulation must be specified when ordering. Our special order form includes this chart to assist in ordering desired angulation. Note: For some pre-adjusted appliances, the crown tip is different than standard edgewise appliances. Consult pre-adjusted appliances section of this catalog for prescribed crown tip and angulation degrees applicable to specific techniques. Patient s Right (+) Angulation Crowns tipped mesially; roots inclined distally. (-) Angulation Crowns tipped distally; roots inclined mesially. Patient s Left Applicable to Standard Edgewise and Torqued Edgewise (-) Torque Crowns - Lingual (+) Torque Crowns - Labial Brackets to Anteriors and G.P. Bicuspids Brackets to Cuspids Brackets to Proportioned Bicuspids Mesial-horizontal center of the base of archwire slot is located on horizontal centerline of band. Offset incisally whereby the horizontal centerline of the base of the archwire slot is aligned with the shoulder of the labial-incisal extension of the band. Slightly offset occlusally whereby occlusal edge of the tie-wing is located approximately.0075 in. (.2 mm) from the occlusal edge of the band. Order Online! www.3munitek.com USA and PR 1-800-423-4588 Canada 1-800-443-1661

Light Wire Attachments Standard Edgewise Welding Reference Light Wire Attachments Brackets to Anteriors and Bicuspids Brackets to Cuspids Single Buccal Tube to Molars /Gingival Underslot of bracket centered on band. /Gingival Underslot of bracket offset incisally so incisal edge of archwire slot is aligned with shoulder of labial-incisal extension of band. Mesial edge of buccal tube bisects mesial cusp. /Gingival Gingival edge of tube is.048 in. (1.2 mm) from gingival edge of band. Standard Edgewise Welding Reference Brackets to Anteriors and Bicuspids Brackets to Cuspids Single Buccal Tube to Molars * For proportioned bicuspid bands, bracket is slightly offset occlusally whereby occlusal edge of tie-wings are flush with occlusal edge of band. Offset incisally so centerline of the archwire slot is aligned with shoulder of labial-incisal extension of the band. Mesial edge of buccal tube bisects mesial cusp. slot is.075 in. (1.9 mm) from occlusal edge of band.

Weld Positioning MBT Versatile+ Appliance System First Molars Upper First Molar buccal tube Centerline of buccal tube positioned on buccal indent of band. / Gingival Positioning: edgewise slot is buccal indent CL CL CL 6 31 6 37+ 6 44 SIZE 44 SIZE 37+ SIZE 31 Lower First Molar Centerline of the buccal tube is positioned.040 in. (1.0 mm) distal, from the mesial buccal indent. / Gingival Positioning: edgewise slot is 6 31 Mesial 6 37+ 6 44 Buccal.040 Indent.040.040 SIZE 31 tube SIZE 37+ SIZE 44 Order Online! www.3munitek.com USA and PR 1-800-423-4588 Canada 1-800-443-1661

Weld Positioning MBT Versatile+ Appliance System Second Molars Upper Second Molar buccal tube buccal indent Centerline of buccal tube positioned on the buccal indent of band. 7 28 7 34+ 7 41 / Gingival Positioning: edgewise slot is SIZE 41 SIZE 34+ SIZE 28 Lower Second Molar Indent used for centering Narrow Contour Centerline of buccal tube is positioned at buccal indent (for narrow contour), or at the center of the band (for standard contour or general purpose). 7 28 7 34+ 7 41 / Gingival Positioning: edgewise slot is SIZE 28 SIZE 34+ Buccal Tube and Band Band SIZE 41

Weld Positioning Standard First Molars Upper First Molar Mesial Cusp Mesial edge of buccal tube bisects mesial cusp. Buccal tube mesial edge at 1/2 mesial cusp 6 31 6 37+ 6 44 / Gingival Positioning: edgewise slot is SIZE 44 SIZE 37+ SIZE 31 Lower First Molar Mesial edge of buccal tube bisects mesial cusp. 6 31 6 37+ 6 44 / Gingival Positioning: edgewise slot is SIZE 31 SIZE 37+ Mesial Cusp Buccal tube mesial edge at 1/2 mesial cusp SIZE 44 Order Online! www.3munitek.com USA and PR 1-800-423-4588 Canada 1-800-443-1661

Weld Positioning Standard Second Molars Upper Second Molar Buccal tube mesial edge at 1/2 mesial cusp Mesial edge of buccal tube bisects mesial cusp. Mesial cusp 7 28 7 34+ 7 41 / Gingival Positioning: edgewise slot is SIZE 41 SIZE 34+ SIZE 28 Lower Second Molar Mesial edge of buccal tube bisects mesial cusp (for narrow contour), mesial edge of buccal tube is 1/4 of the band width (for standard contour or general purpose). 7 28 7 34+ 7 41 / Gingival Positioning: edgewise slot is SIZE 28 SIZE 34+ (Mesial cusp Narrow contour only) Band (Standard Contour and General purpose) Buccal tube mesial edge at 1/2 Mesial cusp, or 1/4 Band SIZE 41

Comparison of Prescriptions Weld Positioning for Upper First Molar MBT Versatile+ Appliance System & M-D Definition: buccal tube positioned at center of band. buccal indent CL buccal tube CL CL CL CL 6 31 6 34 6 37+ 6 41 6 44 As the band size increases, the distance from the mesial side of the band to the mesial side of the buccal tube increases. The center of the buccal tube stays centered on the band (regardless of the tube size). Standard & Level Anchorage Definition: Mesial edge of buccal tube placed at the center of the mesial cusp. CL CL CL CL CL 6 31 6 34 6 37+ 6 41 6 44 Mesial Cusp As the band size increases, the mesial cusp distance increases. The distance from the mesial side of the band to the mesial side of the buccal tube will increase (longer buccal tubes will extend further distal). Aligning & Measuring Band Measurement and Alignment To measure the placement of the buccal tube on the band, the band must first be aligned using two features. A tangent line between the mesial cusp and distal cusp is used. Buccal Tube Measurement MBT Versatile+ Appliance System, Level Anchorage or The center of the tube is defined as 1/2 of the flange or body width. Standard or Level Anchorage The mesial side of the buccal tube is taken at the intersection of the mesial side and the flange. Tangent Line 6 44 Intersection of Flange & Mesial side Body Flange Order Online! www.3munitek.com USA and PR 1-800-423-4588 Canada 1-800-443-1661

Comparison of Prescriptions Weld Positioning for Lower First Molar MBT Versatile+ Appliance System Definition: the buccal tube is positioned.040 (1.0 mm) distal, from the mesial buccal indent. Mesial-Buccal Indent 6 31.040.040.040.040.040 6 34 6 37+ 6 41 6 44 As the band size increases, the distance from the mesial side of the band to the mesial-buccal indent increases. The buccal tube stays.040 (1.0 mm) distal from the Mesial buccal indent (regardless of the tube size). Standard Definition: Mesial edge of buccal tube is placed at the center of the mesial cusp. Center of cusp Mesial Cusp 6 31 6 34 6 37+ 6 41 6 44 As the band size increases, the mesial cusp distance increases. The distance from the mesial side of the band to the mesial side of the buccal tube will increase (longer buccal tubes will extend further distal). Level Anchorage and M-D Defintion: buccal tube is at center of band. Band width Buccal Tube and Band 6 31 6 34 6 37+ 6 41 6 44 As the band size increases, the distance from the mesial side of the band to the mesial side of the buccal tube increases. The center of the buccal tube stays centered on the band (regardless of tube size). Aligning & Measuring Band Measurement and Alignment To measure the placement of the buccal tube on the band, the band must first be aligned using two features. A tangent line between the mesial cusp and distal cusp is used. Buccal Tube Measurement MBT Versatile+ Appliance System, Level Anchorage or The center of the tube is defined as 1/2 of the flange or body width. Standard The mesial side of the buccal tube is taken at the intersection of the mesial side and the flange. Tangent Line 6 44 Intersection of Flange & Mesial side Body Flange

Comparison of Prescriptions Weld Positioning for Upper Second Molar MBT Versatile+ Appliance System, M-D & Level Anchorage Definition: buccal tube positioned on buccal indent. buccal tube buccal indent 7 28 7 31 7 34+ 7 37 7 41 As the band size increases, the distance from the mesial side of the band to the mesial side of the buccal tube increases. The center of the buccal tube stays centered on the band (regardless of tube size). Standard Definition: Mesial edge of buccal tube placed at the center of mesial cusp. 7 28 7 31 7 34+ 7 37 7 41 Mesial Cusp As the band size increases, the mesial cusp distance increases. The distance from the mesial side of the band to the mesial side of the buccal tube will increase (longer buccal tubes will extend further distal). Aligning & Measuring Band Measurement and Alignment To measure the placement of the buccal tube on the band, the band must first be aligned using two features. A tangent line between the mesial cusp and distal cusp is used. Tangent Line 7 41 Buccal Tube Measurement MBT Versatile+ Appliance System, Level Anchorage or The center of the tube is defined as 1/2 of the flange or body width. Standard The mesial side of the buccal tube is taken at the intersection of the mesial side and the flange. Intersection of Flange & Mesial side Body Flange Order Online! www.3munitek.com USA and PR 1-800-423-4588 Canada 1-800-443-1661

Comparison of Prescriptions Weld Positioning for Lower Second Molar MBT Versatile+ Appliance System or M-D Definition: buccal tube positioned at center of band. Band Buccal Tube and Band 7 28 7 31 7 34+ 7 37 7 41 As the band size increases, the distance from the mesial side of the band to the mesial side of the buccal tube increases. The center of the buccal tube stays centered on the band (regardless of tube size). Standard Definition: Mesial edge of buccal tube is positioned at 1/4 of the band width. Band 1/4 Band 7 28 7 31 7 34+ 7 37 7 41 As the band size increases, the mesial cusp distance increases. The distance from the mesial side of the band to the mesial side of the buccal tube will increase (longer buccal tubes will extend further distal). Aligning & Measuring Band Measurement and Alignment To measure the placement of the buccal tube on the band, the band must first be aligned using two features. A tangent line between the mesial cusp and distal cusp is used. Buccal Tube Measurement MBT Versatile+ Appliance System, Level Anchorage or The center of the tube is defined as 1/2 of the flange or body width. Standard The mesial side of the buccal tube is taken at the intersection of the mesial side and the flange. 7 41 Intersection of Flange & Mesial side Body Flange Tangent Line

Lingual Molar Attachments Sheaths Molar Hooks Combination Hook/Lug /Gingival /Gingival with hook to occlusal (hook opening toward gingival). /Gingival hook is centered occlusal-gingivally. Buttons Hi-Profile Cleats Low-Profile Cleats On all molars with buccal attachment: button bisects mesial cusp. On G.P. molars, without buccal attachment: button is centered mesio-distally. Also applies to upper 2nd molars with or without buccal attachment. On all molars with buccal attachments: cleat bisects mesial cusp. On G.P. molars, without buccal attachment: button is centered mesio-distally. Also applies to upper 2nd molars with or without buccal attachment. Welding flange is.020 in. (.51 mm) from occlusal edge of band. Welding flange is.020 in. (.51 mm) from occlusal edge of band. Ball Hook Mesial edge of flange centered mesio-distally; ball toward distal. /Gingival Level Anchorage System Attachments Specifications vary somewhat from standard positioning. Please refer questions regarding Level Anchorage System specifications to your 3M Unitek representative, or 3M Unitek Preweld Customer Service. Order Online! www.3munitek.com USA and PR 1-800-423-4588 Canada 1-800-443-1661