Start with ME. LEAVE A LEGACY OF EXCELLENT OUTCOMES FOR PATIENTS WITH ASTIGMATISM. TECNIS TORIC 1-PIECE IOL

Similar documents
Start with ME. LEAVE A LEGACY OF EXCELLENT OUTCOMES FOR EACH PATIENT S LIFESTYLE. TECNIS MULTIFOCAL FAMILY OF 1-PIECE IOLs

Getting Started GUIDE. TECNIS Symfony IOL and TECNIS Symfony TORIC IOL. TECNIS SYMFONY IOL pg 1

Bringing astigmatism AND presbyopia into focus.

PRODUCT INFORMATION Alcon Laboratories, Inc.

FROM CATARACTS TO CLARITY

go the distance NEW AcrySof IQ ReSTOR +2.5 D It s a wide world. Help your patients and everywhere in between.

MultifocalS: A Reference Guide

WHAT SETS ACTIVEFOCUS DESIGN APART? THE DIFFERENCE IS IN THE DISTANCE.

Electronic poster presentations

Clinical Evaluation of the BunnyLens IOL

Premium Implant Options for the Cataract Patient. Justin Schweitzer, OD, FAAO Vance Thompson Vision Sioux Falls, South Dakota

Optometric Postoperative Cataract Surgery Management

Sulcoflex Trifocal Supplementary IOL. When expectations and outcomes align. An elegant solution for the correction of presbyopia MADE IN UK

Physical Characteristics of Trulign Toric Posterior Chamber Intraocular Lens. Models. 11.5mm. 5.0 mm. 10.5mm. Rectangular

TREAT CATARACTS AND ASTIGMATISM WITH ONE PROCEDURE

Patient Information Brochure. Cataract

Cataracts 20/20: The Optometrist s Role in Pre and Post-Op Care In The Era Of Specialty Lenses

You can see vivid colours again after cataract management at Sankar Foundation Eye Hospital

2/6/2018 RAPID FIRE PANEL: CO-MANAGEMENT OF UNUSUAL SITUATIONS IN CATARACT SURGERY. Andrew Siedlecki, M.D. Richard Orlando, M.D.

Advanced Eyecare of Orange County/ Kim T. Doan, M.D.

2/6/2018. Andrew Siedlecki, M.D.

Clinical Pearls. A Quick Guide to Crystalens AO Accommodating Lens

FROM PRE-OP TO POST-OP, OPTIMIZE YOUR WORKFLOW WITH THE CATALYS SYSTEM MOBILE PATIENT BED.

PRODUCT INFORMATION Alcon Laboratories, Inc. STERILE UV-Absorbing PMMA Single-Piece Posterior Chamber Lenses

RayOne Trifocal IOL. The preloaded platform that performs again and again MADE IN UK

RLE (Refractive Lens Exchange)- Bootcamp. Christopher Blanton, MD April 28,2018

More possibilities after.

FROM PRE-OP TO POST-OP, HELP OPTIMIZE YOUR WORKFLOW WITH THE CATALYS SYSTEM MOBILE PATIENT BED.

Vision and Aging. Driving (source of independence)

Informed Consent For Cataract Surgery. And/Or Implantation of an Intraocular Lens INTRODUCTION

Pediatric traumatic cataract Presentation and Management. Dr. Kavitha Kalaivani Pediatric ophthalmology Sankara Nethralaya Nov 7, 2017

Appendix Table 1. Ophthalmic drugs approved by the US Food and Drug Administration,

Guide to modern day cataract surgery

Cataract Surgery: What You Must Know Before Having It Done

Learn Connect Succeed. JCAHPO Regional Meetings 2017

Cataract Surgery: Patient Information

Intrascleral-fixated intraocular lenses for aphakic correction in the absence of capsular support

Multifocal Toric Swiss Army Knife For the Cataract and Refractive Surgeon

INFORMED CONSENT FOR CATARACT SURGERY

The cataract laser technology of tomorrow is here for you today. See inside to learn about all your exciting new options

Refractive Dilemma. Challenging Case

Lens and Cataract Surgery Update 2008

2/26/2017. Sameh Galal. M.D, FRCS Glasgow. Lecturer of Ophthalmology Research Institute of Ophthalmology

REFRACTIVE LENS SURGERY: WHEN AND WHY?

YOUR EYES ARE UNIQUE.

The visual outcome after implantation of the Multifocal Intra Ocular Lens. Dr.Bhargav Dave National Institute of Ophthalmology Pune

Progressive (multifocal diffractive) aspherical hydrophilic acrylic sterile intraocular lens for implantation into the capsular bag

The Visian ICL Advantages

Your First Appointment:

On the haptics of several PMMA lenses there are holes to ease scleral fixation.

DRAFT CONSENSUS STATEMENT FOR COMMENT October

Strategies for Managing Advanced Technology IOLs in Today s Cataract Patient

Intraocular lens for implantation into the capsular bag

Clinical Study Clinical Outcomes after Uncomplicated Cataract Surgery with Implantation of the Tecnis Toric Intraocular Lens

State of the art: femtosecond laser cataract surgery

Late Intraocular Lens Subluxation in Patients with Uveitis

Pre-Operative Health Questionnaire. 3. Are you currently taking any of the following medications for. glaucoma: TRAVATAN LUMIGAN XALATAN

KNOW THE OPTIONS. Discover how the latest advances in vision correction can improve your sight.

Not Your Grandfather s Cataract Surgery-Cataract Surgery for 2015 and Beyond

The pinnacle of refractive performance.

NORTHWEST EYE SURGEONS WHATCOM EYE SURGEONS September October 2014 PARTNERING WITH OPTOMETRY FOR EDUCATION AND PATIENT CARE

LUCIAN BLAGA UNIVERSITY SIBIU CONTRIBUTIONS TO THE EXTENSION OF INDICATIONS OF THE TORIC INTRAOCULAR LENSES IMPLANTATION

ASCRS completes fourth annual Clinical Survey

Subnormal Vision in Uneventful Cataract Surgery after 6 Weeks Hospital Based Study

Learn Connect Succeed. JCAHPO Regional Meetings 2017

The cataract laser technology of tomorrow is here for you today.

What to Expect following your Crystalens procedure. SU6161-Post Op Brochure REVISED Landscape.indd 1

They are updated regularly as new NICE guidance is published. To view the latest version of this NICE Pathway see:

Clinical study of traumatic cataract and its management

CONSENT FOR CATARACT SURGERY REQUEST FOR SURGICAL OPERATION / PROCEDURE AND ANAESTHETIC

3/17/2018 CHALLENGES IN MODERN CATARACT SURGERY BRIEF HISTORY OF CATARACT SURGERY

Cataract Surgery Patient Information

ALTERNATIVES TO PHAKIC IMPLANT SURGERY

CATARACT & LENS SURGERY CATARACT SURGERY

Introduction. We are finally using a laser!!! The Use of a Femtosecond Laser for Complex Cataract Procedures. Financial Disclosure

Pediatric cataract. Nikos Kozeis MD, PhD, FICO, FEBO, MRCOphth. Surgical challenges and postoperative complications

Ophthalmology. Cataract

Enhancements After Premium IOL Cataract Surgery: Tips, Tricks, and Outcomes

Cataract Surgery: Information for patients. Back of eye. Vitreous. Retina. Lens

SECONDARY CAPSULOTOMY USING THE FEMTOSECOND LASER. Surendra Basti, MD Northwestern University Feinberg School of Medicine, Chicago, IL

Cataract. What is a Cataract?

What I Am Doing Now That I Was Not Doing One Year Ago

Cataract. What is a Cataract?

Anterior Segment Cataract and Refractive

Why I Have Decided to Implant Trifocal IOLs Technology in My Own Eyes

Evaluation of Toric Intraocular Lenses in Patients With Low Degrees of Astigmatism

Cataract and cornea. Miltos O. Balidis PhD, FEBOphth,ICOphth ATHENS

Evolution in Visual Freedom.

Long-term Experiences Recognize FineVision as the Gold Standard

Preliminary Programme

Keratoconus Clinic. Optometric Co-management Opportunities

CONTROLLED PRECISION.

Measure #192: Cataracts: Complications within 30 Days Following Cataract Surgery Requiring Additional Surgical Procedures

Mr Vaughan Tanner BSc MBBS FRCOphth Consultant Ophthalmic Surgeon

Relevant and Reliable Systematic Review Mapped to this Section. Relevance of Review to other sections of AAO PPP- 2011

Optometry s Partner. Everyone, Everywhere, Every Day. in Bringing Healthy Vision to. Johnson & Johnson Vision

Cataracts in adults: management

Changing the Game of Premium IOLS

Practical Care of the Cataract Patient with Retinal Disease

Cataract and Refractive Surgery Co-Management Policy and Procedure Manual

Transcription:

LEAVE A LEGACY OF EXCELLENT OUTCOMES FOR PATIENTS WITH ASTIGMATISM. Start with ME. TECNIS TORIC 1-PIECE IOL INDICATIONS: The TECNIS Toric 1-Piece Posterior Chamber Lens is indicated for the visual correction of aphakia and pre-existing corneal astigmatism of one diopter or greater in adult patients with or without presbyopia in whom a cataractous lens has been removed by phacoemulsification and who desire improved uncorrected distance vision, reduction in residual refractive cylinder, and increased spectacle independence for distance vision. The device is intended to be placed in the capsular bag. See Indications and Important Safety Information on page 12.

THE LEGACY YOU LEAVE IS THE LIFE I LIVE. For patients with astigmatism, that legacy is just as critical. Your patients vision is only as good as the IOL you leave behind, so don t leave a legacy that s lacking. The TECNIS Toric 1-Piece IOL not only provides excellent spherical correction but also delivers beautifully sharp vision and sustainable performance, even in low-light conditions. And since it s backed by proven optical excellence, the legacy you leave can be truly remarkable for patients with cataracts and astigmatism. CHOOSE THE TECNIS TORIC IOL FOR: SHARPEST VISION The sharpest vision for patients with astigmatism ENHANCED FUNCTIONALITY Enhanced functionality and the best low-light performance LONG-TERM SUSTAINABILITY Long-term stability and satisfaction

ALIGN YOUR OPPORTUNITIES. Meet cataract and astigmatism demand, all at once. More than one third of the population has > 1 D of astigmatism. Yet, only 7% of IOLs implanted in the U.S. are toric IOLs.* 1 With plenty of opportunity yet to be tapped, toric procedures are already a rapidly growing premium market segment 2 of ~268,000 procedures.** As demand rises, will you be prepared to face the challenges of combined cataract and astigmatism management? With TECNIS Toric IOLs, you ll have the tools you need to give your patients the consistent, high-quality outcomes they deserve. MORE 7 % THAN of the U.S. population has > 1 D of astigmatism ONLY of lenses delivered are toric IOLs Advanced technology IOL patients are paying for the best possible visual outcomes. Based on my experience, the TECNIS Toric IOL decreases astigmatism while improving visual quality. I ve implanted many TECNIS Toric IOLs within the closely monitored IDE study. I know this IOL delivers exceptional results. Kevin Waltz, OD, MD, Indianapolis, Indiana * Data forecasted for 2013. ** Data forecasted for 2014. TECNIS TORIC 1-PIECE IOL pg 3

SHARPEST VISION LEAVE A LEGACY OF OUTSTANDING VISION. As the quantity of toric procedures increases, trust your legacy to an IOL that delivers exceptional visual quality. The TECNIS Toric IOL adheres to a high standard of optical excellence so you can give each patient the sharp, brilliant vision they never thought possible. EXCELLENT ASTIGMATISM CORRECTION In a clinical study evaluating the efficacy of TECNIS Toric IOLs for astigmatism correction in cataract patients, 94% of eyes achieved 0.5 D of residual refractive cylinder, and 98% of eyes achieved 0.75 D.* 3 POST-OP CYLINDER CORRECTION RESULTS: Mean 0.18 D SD 0.30 94 % of eyes have 0.5 D 98 % of eyes have 0.75 D *In a separate (IDE) study, 72.3% of ZCT150 eyes achieved 0.50 diopters of residual refractive cylinder. By comparison, 69.3% AcrySof IQ Toric SA60T3 eyes achieved 0.50 D of residual refractive cylinder. **Modular Transfer Function (MTF) is a measure of the amount of contrast transferred by the optics in a visual system. The higher the MTF value, the more contrast transferred to the image, resulting in higher image contrast. pg 4 TECNIS TORIC 1-PIECE IOL

SUPERIOR IMAGE CONTRAST Your patients deserve vision that s as sharp as it is clear, so give them a lens that delivers extraordinary image contrast. MTF** AT 50 C/MM WHITE, 3 MM PUPIL 0.60 0.50 0.40 0.30 0.20 Up to 16 % better image contrast in 3 mm pupils 4 16% MTF** AT 50 C/MM WHITE, 5 MM PUPIL 0.60 0.50 0.40 0.30 0.20 Up to 31 % better image contrast in 5 mm pupils 4 31% 88 % of patients achieved 20/20 or better monocular corrected distance visual acuity 5 0.10 0.10 0.00 3 mm High Cylinder Meridian 3 mm Low Cylinder Meridian 0.00 5 mm High Cylinder Meridian 5 mm Low Cylinder Meridian TECNIS TORIC IOL (ZCT225) AcrySof IQ TORIC IOL (SN6AT4) TECNIS TORIC IOL (ZCT225) AcrySof IQ TORIC IOL (SN6AT4) TECNIS TORIC 1-PIECE IOL pg 5

ENHANCED FUNCTIONALITY LEAVE A LEGACY OF LIVING. Your patients are far from ready to throw in the towel. They ve got places to go and sights to see and they ll see them all through the IOL you choose. Give them a lens designed to function in real-world conditions, such as in low light or without glasses, so they can experience each day with outstanding clarity. CONFIDENT DRIVING AT NIGHT WITHOUT GLASSES* Your legacy is for life, not just perfect lighting conditions. Empower your patients to get back to their everyday activities, such as driving, with an IOL that delivers excellent functional vision and low-light performance. 91.9 % of patients reported no difficulty with night driving without glasses at 6 months. 4 DIFFICULTY WITH DRIVING AT NIGHT WITHOUT GLASSES AT 6 MONTHS** NO DIFFICULTY (%) 100 80 60 40 20 0 91.9 73.1 TECNIS Toric IOL ZCT150 TECNIS 1-Piece Monofocal IOL ZCB00 Bilateral subjects in the randomized control arm and open label arm safety population. *As control eyes had 1.5 D of preoperative Kcyl, results for all toric eyes pooled are not to be compared to control values. **Difficulty with certain activities without glasses at six months, bilateral subjects in the randomized control arm and the open label arm safety population. pg 6 TECNIS TORIC 1-PIECE IOL

Best low-light performance TECNIS TORIC 1-PIECE IOL pg 7

LONG-TERM SUSTAINABILITY LEAVE A LASTING LEGACY. What good is a lens if it s not built to last? Make your legacy one you can continually be proud of with an IOL that delivers exceptional stability, high patient satisfaction and stunning visual performance. OUTSTANDING POST-OP ROTATIONAL STABILITY Stability is especially important for those with astigmatism. TECNIS Toric IOLs demonstrate an excellent 2.74 mean axis change between the baseline and six months. 4 2.74 Mean Axis Change POST-OP ROTATIONAL STABILITY FOR ALL TORIC FIRST EYES 4 IMPLANTED EYES (%) 100 80 60 40 20 93 94 MEASURED R 1 Month vs. 3 Months (n=156) 3 Months vs. 6 Months (n=152) Eyes with photographic axis data at two or more consecutive visits 0 6 4 1 2 0 0 0 5 6 9 10 15 >16 MEASURED ROTATION ( ) WARNINGS: Rotation of the TECNIS Toric 1-Piece IOL away from its intended axis can reduce its astigmatic correction. Misalignment greater than 30 may increase postoperative refractive cylinder. If necessary, lens repositioning should occur as early as possible prior to lens encapsulation. pg 8 TECNIS TORIC 1-PIECE IOL

NOT ASSOCIATED WITH GLISTENINGS Glistenings can inhibit your patients vision by decreasing visual acuity 6 and causing light scatter, which can result in image contrast reduction. 7,8 TECNIS IOLs are made using an innovative material that is not associated with glistenings, unlike another leading IOL. 9 High patient satisfaction DARK FIELD IMAGES OF COMPETITOR IOL 8 10X 40X 97 % of patients would choose to have the TECNIS Toric IOL implanted again 4 TECNIS TORIC 1-PIECE IOL pg 9

TECHNICAL SPECIFICATIONS Powers: +5.0 D to +34.0 D in 0.5 diopter increments: Lens Model: ZCT150 ZCT225 ZCT300 ZCT400 ZCT450 ZCT525 ZCT600 Cylinder Powers: 1.50 D 2.25 D 3.00 D 4.00 D 4.50 D 5.25 D 6.00 D Corneal Plane:* 1.03 D 1.54 D 2.06 D 2.74 D 3.08 D 3.60 D 4.11 D Corneal Astigmatism Correction Range: 0.75 1.50 D 1.50 2.00 D 2.00 2.75 D 2.75 3.62 D 3.00 3.50 D 3.50 4.00 D 4.00 4.75 D Diameter: Optic Overall Length: Shape: Material: 6.0 mm 13.0 mm Biconvex, anterior toric aspheric surface UV-blocking hydrophobic acrylic Refractive Index: 1.47 Edge Design: Haptic Design: A-Constant: ProTEC continuous 360 posterior, frosted square edge Offset from optic with Tri-Fix 3-point fixation 119.3 (Optical biometry) 118.8 (Ultrasound biometry) REFERENCES 1. Market Scope, Data as of 2013. Comprehensive Report on Global IOL Market. 2. Market Scope, Data as of 2013. Ophthalmic Market Perspectives. 3. Black D, Efficacy of Hydrophobic Acrylic Toric IOL to Correct Astigmatism in Cataract Patients. Presented at ASCRS 2015. 4. Data on File, Abbott Medical Optics Inc., 2015. 5. TECNIS Toric 1-Piece IOL [package insert]. Abbott Medical Optics Inc., Santa Ana, Calif. 6. Christiansen G, et al. Glistenings in the AcrySof intraocular lens: pilot study. J Cataract Refract Surg. 2001;27:728-33. 7. Nagata M, et al. Clinical evaluation of the transparency of hydrophobic acrylic intraocular lens optics. J Cataract Refract Surg. 2010 Dec;36(12):2056-60. 8. Van der Mooren M, Franssen L, Piers P. Effects of glistenings in intraocular lenses. Biomed Opt Express. 2013 Jul 11;4(8):1294-3041. 9. Data on File, Abbott Medical Optics Inc., 2013. *Based on average pseudophakic human eye. Derived from clinical evaluation results of the TECNIS 1-Piece platform. Value theoretically derived for a typical 20.0 D lens. Johnson & Johnson Vision recommends that surgeons personalize their A-constant based on their surgical techniques and equipment, experience with the lens model, and postoperative results. pg 10 TECNIS TORIC 1-PIECE IOL

WHAT WILL YOUR LEGACY BE? Your patients vision is only as good as the IOL you leave behind. Toric demand is on the rise and though astigmatism can present challenges, your patients expect incredible outcomes. With the TECNIS Toric 1-Piece IOL, you can be confident you re giving each patient the sharpest vision, outstanding functionality and incredible stability and satisfaction. Your patients live their lives with the IOL you choose, so give them a dependable, high-quality solution for cataracts and astigmatism, all at once. Don t wait to give your patients with astigmatism a legacy of excellent outcomes. Start now with the TECNIS Toric IOL.

INDICATIONS AND IMPORTANT SAFETY INFORMATION FOR THE TECNIS TORIC 1-PIECE IOLs Rx Only ATTENTION: Reference the Directions for Use for a complete listing of Indications and Important Safety Information. INDICATIONS: The TECNIS Toric 1-Piece Posterior Chamber Lens is indicated for the visual correction of aphakia and pre-existing corneal astigmatism of one diopter or greater in adult patients with or without presbyopia in whom a cataractous lens has been removed by phacoemulsification and who desire improved uncorrected distance vision, reduction in residual refractive cylinder, and increased spectacle independence for distance vision. The device is intended to be placed in the capsular bag. WARNINGS: Physicians considering lens implantation should weigh the potential risk/benefit ratio for any circumstances described in the TECNIS Toric 1-Piece IOL Directions for Use that could increase complications or impact patient outcomes. These circumstances include recurrent severe anterior or posterior segment inflammation or uveitis; surgical difficulties at the time of cataract extraction, which may increase the potential for complications (e.g., persistent bleeding, significant iris damage, uncontrolled positive pressure or significant vitreous prolapse or loss); a compromised eye due to previous trauma or developmental defects in which appropriate support of the IOL is not possible; circumstances that would result in damage to the endothelium during implantation; suspected microbial infection; or patients in whom neither the posterior capsule nor the zonules are intact enough to provide support for the IOL. Children under the age of 2 years are not suitable candidates for intraocular lenses. The clinical study for the TECNIS Toric 1-Piece IOL did not show evidence of effectiveness for the treatment of preoperative corneal astigmatism of less than one diopter. The TECNIS Toric 1-Piece IOL should not be placed in the ciliary sulcus. Rotation of the TECNIS Toric 1-Piece IOL away from its intended axis can reduce its astigmatic correction. Misalignment greater than 30 may increase postoperative refractive cylinder. If necessary, lens repositioning should occur as early as possible prior to lens encapsulation. PRECAUTIONS: Prior to surgery, the surgeon must inform prospective patients of the possible risks and benefits associated with the use of this device and provide a copy of the patient information brochure to the patient. Do not soak or rinse with any solution other than sterile balanced salt solution or sterile normal saline. Do not store in direct sunlight or at greater than 113 F. Carefully remove all viscoelastic and do not over-inflate the capsular bag at the end of the case. Residual viscoelastic and/or over-inflation of the capsular bag may allow the lens to rotate, causing misalignment of the TECNIS Toric 1-Piece IOL with the intended axis of placement. When the insertion system is used improperly, the haptics of the TECNIS Toric 1-Piece IOL may become broken. Please refer to the specific instructions for use provided with the insertion instrument or system. The use of methods other than the TECNIS Toric Calculator to select cylinder power and appropriate axis of implantation were not assessed in the clinical study and may not yield similar results. Accurate keratometry and biometry in addition to the use of the TECNIS Toric Calculator (www.tecnistoriccalc.com) are recommended to achieve optimal visual outcomes. The safety and effectiveness of the toric intraocular lens have not been substantiated in patients with certain preexisting ocular conditions, and intraoperative complications. Careful preoperative evaluation and sound clinical judgment should be used by the surgeon to decide the benefit/risk ratio before implanting a lens in a patient with one or more of these conditions. Preexisting conditions include: choroidal hemorrhage, chronic severe uveitis, concomitant severe eye disease, extremely shallow anterior chamber, medically uncontrolled glaucoma, microphthalmos, non-age-related cataract, proliferative diabetic retinopathy (severe), severe corneal dystrophy, severe optic nerve atrophy, or irregular corneal astigmatism. Intraoperative conditions include: excessive vitreous loss, capsulotomy by any technique other than a circular tear, the presence of radial tears known or suspected at the time of surgery, situations in which the integrity of the circular tear cannot be confirmed by direct visualization, cataract extraction by techniques other than phacoemulsification or liquefaction, situations where the need for a large capsulotomy can be anticipated (e.g., diabetics, retinal detachment in the fellow eye, peripheral retinal pathology, etc.), capsular rupture, significant anterior chamber hyphema, uncontrollable positive intraocular pressure, zonular damage. All preoperative surgical parameters are important when choosing a toric lens for implantation, including preoperative keratometric cylinder (magnitude and axis), incision location, surgeon s estimated surgically induced astigmatism (SIA) and biometry. Variability in any of the preoperative measurements can influence patient outcomes and the effectiveness of treating eyes with lower amounts of preoperative corneal astigmatism. All corneal incisions were placed temporally in the clinical study. If the surgeon chooses to place the incision at a different location, outcomes may be different from those obtained in the clinical study. Note that the TECNIS Toric Calculator incorporates the surgeon s estimated SIA and incision location when providing IOL options. Do not reuse, resterilize, or autoclave. ADVERSE EVENTS: Potential adverse events during or following cataract surgery with implantation of an IOL may include but are not limited to: endophthalmitis/intraocular infection, hypopyon, pupillary block, retinal detachment, IOL dislocation, persistent corneal stromal edema, persistent cystoid macular edema, or secondary surgical intervention (including implant repositioning, removal, or other surgical procedure). The most frequently reported cumulative adverse event that occurred during the TECNIS Toric 1-Piece IOL clinical trial was surgical re-intervention which occurred at a rate of 3.4% (lens repositioning procedures and retinal repair procedures). Other reported events included cystoid macular edema which occurred at a rate of 2.9% and retinal detachment which occurred at a rate of 0.6%. Dr. Kevin Waltz is a paid consultant for Johnson & Johnson Vision. TECNIS, Tri-Fix and ProTEC are trademarks owned by or licensed to Abbott Laboratories, its subsidiaries or affiliates. AcrySof is a trademark owned by or licensed to Novartis AG Corp., its subsidiaries or affiliates. 2017 Abbott Medical Optics Inc. www.tecnisiol.com PP2017CT0652 TEC15-14