INSTRUCTIONS FOR USE FOR: English

Similar documents
eptfe Vascular Graft Instructions for Use

INSTRUCTIONS FOR USE FOR:

ProCol Vascular Bioprosthesis

Peel-Apart Percutaneous Introducer Kits for

INSTRUCTIONS FOR USE FOR:

1. Brouwer DJ. Cannulation camp: basic needle cannulation training for dialysis staff. Dialysis & Transplantation 1995;24(11):

Desara TV and Desara Blue TV

CAREFULLY READ ALL INSTRUCTIONS PRIOR TO USE

Instructions for Use Reprocessed LASSO Circular Mapping Diagnostic Electrophysiology (EP) Catheter

Document No. BMB/IFU/40 Rev No. & Date 00 & 15/11/2017 Issue No & Date 01 & 15/11/2017

The SplitWire Percutaneous Transluminal Angioplasty Scoring Device. Instructions for Use

ER REBOA Catheter. Instructions for Use

Cardiva Catalyst III INSTRUCTIONS FOR USE

ASDIN 7th Annual Scientific Meeting

Home Health Foundation, Inc. To create more permanent IV access for patients undergoing long term IV therapy.

Talent Abdominal Stent Graft

Single Use Curlew TM Multiple Biopsy Forceps

Technique Guide KISSloc Suture System

Absorbable Woven Polyglycolic Acid Mesh Tube (Absorbable Nerve Conduit Tube) INSTRUCTIONS FOR USE 2 6

AXS Catalyst Distal Access Catheter

Per-Q-Cath* PICC Catheters with Excalibur Introducer* System

Implanting an Adult Rat with the Single-Channel Epoch Transmitter for Recording Electrocardiogram in the Type II electrode configuration.

Balloon in Balloon (BIB )

DURABLE. CONSISTENT. SAFE. IN.PACT Admiral Drug-Coated Balloon

1 Description. 2 Indications. 3 Warnings ASPIRATION CATHETER

ARROW ENDURANCE. Extended Dwell Peripheral Catheter System. Rx only.

Introduction What Causes Peripheral Vascular Disease? How Do Doctors Treat Peripheral Vascular Disease?... 9

Desara and Desara Blue

with Blom-Singer Gel Cap Insertion System

Introduction 3. What is Peripheral Vascular Disease? 5. What Are Some of the Symptoms of Peripheral Vascular Disease? 6

Technique Guide. *smith&nephew N8TIVE ACL Anatomic ACL Reconstruction System

Radux StandTall Instructions for Use Sheath Extender and Securement Clasp

EndoRelease ENDOSCOPIC CUBITAL TUNNEL RELEASE SYSTEM

PTA Balloon Dilatation Catheter

Initial placement 24FR Pull PEG kit REORDER NO:

3M Tegaderm CHG Chlorhexidine Gluconate I.V. Securement Dressing Description 3M Tegaderm CHG Chlorhexidine Gluconate I.V. Securement Dressing is used

SYMBOLOGY. = Manufacturer. = Manufacturing Serial Number. = Manufacturing Lot Number = Catalog Number LOT REF. = Do not resterilize Single Use Only

St. Jude Medical 8-Channel Adapter. Clinician's Manual

Echo PS Positioning System with Ventralight ST Mesh or Composix L/P Mesh

Integra. TenoGlide Tendon Protector Sheet SURGICAL TECHNIQUE

Parents Guide to Pediatric Congenital Heart Defects. Cardiac Surgical Solutions. PERFORMANCE through experience

The Ceterix NovoStitch Disposable Suture Passer. Do Not Reuse

Lutonix AV Clinical Trial

ASEPT. Pleural Drainage System INSTRUCTIONS FOR USE REF LOT STERILE EO. Manufactured for: 824 Twelfth Avenue Bethlehem, PA

Directions For Use. All directions should be read before use

FISH device S P. morris INNOVATIVE. SHEATH PROTECTED Femoral Introducer Sheath & Hemostasis Device

2. Need for serial arterial blood gas determinations. 2. Anticipation of the initiation of thrombolytic therapy

CableFIX Xpress Carpometacarpal Fixation System. Operative technique

Split-Stream LONG-TERM HEMODIALYSIS INSTRUCTIONS FOR USE

Assurant Cobalt Iliac BALLOON EXPANDABLE STENT SYSTEM

Ventral Hernia Repair

Initial placement 20FR Guidewire PEG kit REORDER NO:

BACTISEAL Endoscopic Ventricular Catheter (REF & )

HeliMEND Advanced. Absorbable Collagen Membrane. Instructions for Use

ASEPT. Pleural Drainage System INSTRUCTIONS FOR USE. Rx only REF LOT. STERILE EO Sterilized using ethylene oxide

Polyurethane Dual Lumen Occlusion Catheter English Instructions for Use. Polyurethane Dual Lumen Occlusion Catheter

Stratis INSTRUCTIONS FOR USE. Needle-free Injection System. 0.5mL volume (+/-5%)

RECOMMENDED INSTRUCTIONS FOR USE

CORONARY ARTERY BYPASS GRAFTING (CABG) (Part 1) Mark Shikhman, MD, Ph.D., CSA Andrea Scott, CST

The AperFix II System

Saphenous Vein Autograft Replacement

Groshong* PICC and Catheters

Peripheral Intravascular Lithotripsy (IVL) Catheter Instructions for Use (IFU)

RD180 SP TECHNOLOGY GUIDE READ THIS PRODUCT INSERT THOROUGHLY BEFORE USE

Pinit Plate Small Bone Fusion System Bone Plate & Screw System

Doc no: IFU/CPL Issue date: Rev no: 00 Rev date: 1

CLARIVEIN INFUSION CATHETER

Intervention for Lower Extremity PAD: When, why and what?! Robert F Cuff, MD FACS RVT RPVI

Vascu-PICC WITH CUFF PERIPHERALLY INSERTED CENTRAL VEIN ACCESS CATHETER INSTRUCTIONS FOR USE

Jadelle Contraceptive Implants up to 5 years Insertion and Removal

ACL Reconstruction Cross-Pin Technique

FLEXIC ATH LTD. Peripherally Inserted. Instructions n For Use.

Device Preparation (all steps to be performed per standard interventional technique)

Desara Blue OV D I. Sling for Female Stress Urinary Incontinence. Instructions For Use

JuggerLoc Bone-to-Bone System for Ankle Syndesmosis Fixation. Surgical Technique

PTA Balloon Dilatation Catheter

BP and Heart Rate by Telemetry

Integra. DigiFuse Cannulated Intramedullary Fusion System SURGICAL TECHNIQUE

Combat Extremity Vascular Trauma

Surgical Options for revascularisation P E T E R S U B R A M A N I A M

For the Attention of the Operating Surgeon: IMPORTANT INFORMATION ON THE MATRIXRIB FIXATION SYSTEM

Instructions for Use Enbrel (en-brel) (etanercept) for injection, for subcutaneous use Multiple-dose Vial

Duraloc CONSTRAINED LINER

Caution: Federal (U.S.A.) law restricts this device to sale by or on the order of a physician.

SYNPOR POROUS POLYETHYLENE IMPLANTS. For craniofacial and orbital augmentation and reconstruction

Extracapsular Repair Monofilament Nylon Suture

NON-COMPLIANT PTCA RAPID EXCHANGE DILATATION CATHETER

Rotator Cuff Repair using JuggerKnot Soft Anchor 2.9mm Surgical Technique

Technique Guide Small Bone Fusion System

Access More Patients. Customize Each Seal.

Durable outcomes. Proven performance.

Increase Strength, Flexibility, Range of Motion and Endurance. NeckXsystems Guidelines & Exercise. NeckX is Patent Pending

Lab no 1 Structural organization of the human body

Instructions for Use Reprocessed ENDOPATH XCEL Bladeless Endoscopic Trocars and Cannulas. Reprocessed Device for Single Use.

Instructions for Use Enbrel (en-brel) (etanercept) injection, for subcutaneous use Single-dose Prefilled Syringe

CorMatrix ECM Bioscaffold

Tibial Fixation. with TunneLoc Device. Surgical Technique by Mark J. Albritton, M.D. and Sherwin Ho, M.D.

Technique Guide. SynPOR Porous Polyethylene Implants. For craniofacial and orbital augmentation and reconstruction.

Transcription:

INSTRUCTIONS FOR USE FOR: en English fr

INSTRUCTIONS FOR USE FOR: GORE PROPATEN Vascular Graft I. INDICATIONS FOR USE II. III. IV. CONTRAINDICATIONS US CLINICAL EXPERIENCE PACKAGE HANDLING V. TECHNICAL INFORMATION VI. VII. POSSIBLE COMPLICATIONS WITH THE USE OF ANY VASCULAR PROSTHESIS OPERATIVE TECHNIQUES VIII. STERILITY IX. RESTERILIZATION I. INDICATIONS FOR USE GORE PROPATEN Vascular Grafts are intended for use as vascular prostheses for replacement or bypass of diseased vessels in patients suffering occlusive or aneurysmal diseases, in trauma patients requiring vascular replacement, for dialysis access, or for other vascular procedures. II. CONTRAINDICATIONS A. DO NOT use the GORE PROPATEN Vascular Graft in patients with known hypersensitivity to heparin, including those patients who have had a previous incidence of Heparin-Induced Thrombocytopenia (HIT) type II. B. DO NOT use any configuration of GORE PROPATEN Vascular Grafts with Removable Rings, Non-Removable Rings or Integrated Rings for coronary artery bypass or cerebral reconstruction procedures. C. DO NOT use GORE PROPATEN Vascular Grafts as a patch. If cut and used as a patch, GORE PROPATEN Vascular Grafts may lack adequate transverse strength. FOR PATCHING APPLICATIONS: For cardiovascular procedures requiring patch materials, use the appropriate GORE ACUSEAL Cardiovascular Patch. III. US CLINICAL EXPERIENCE Objectives: The primary objective of the US clinical study was to evaluate the safety and effectiveness of the GORE PROPATEN Vascular Graft and demonstrate substantial equivalence to the GORE-TEX Stretch Vascular Graft in a peripheral application. Study Design: This 200-subject, multi-centered, prospective, randomized, singleblind clinical trial was designed to compare the GORE PROPATEN Vascular Graft to the commercially available GORE-TEX Stretch Vascular Graft for occlusive vascular disease in patients requiring primary above-knee arterial bypass. The primary efficacy endpoint was primary patency at 12 months, determined by hemodynamic evidence of blood flow. The primary safety endpoint was the major device-related adverse event rate at 12 months. Study Enrollment: Eighteen (18) US sites enrolled patients in the study; 101 patients received the GORE PROPATEN Vascular Graft while 99 patients received the GORE-TEX Stretch Vascular Graft. All grafts were thin walled with a 6 mm internal diameter. Pre-procedure Subject Information: Demographics and symptom grades were similar between the GORE PROPATEN Vascular Graft and GORE-TEX Stretch Vascular Graft groups. Risk factors were also similar with the exception of diabetes and hyperlipidemia. In the GORE PROPATEN Vascular Graft and GORE-TEX Stretch Vascular Graft groups, respectively, pre-procedure demographics included average age (64.8, 67.3 years) and percent of male subjects (53.5%, 60.6%). In the GORE PROPATEN Vascular Graft and GORE-TEX Stretch Vascular Graft groups, respectively, pre-procedure risk factors included diabetes (27.8%, 14.3%), current tobacco use (55.4%, 49.0%), hypertension (79.2%, 85.7%), and moderately elevated hyperlipidemia controlled through strict diet and medications (58.4%, 43.9%). In the GORE PROPATEN Vascular Graft and GORE-TEX Stretch Vascular Graft groups, respectively, 44.6% and 43.9% of subjects were enrolled with claudication and 55.4% and 56.1% with critical limb ischemia. Efficacy: At the end of the 12-month follow-up, primary patency, secondary patency, and limb salvage rates for the GORE PROPATEN Vascular Graft were 71.2%, 93.9%, and 95.8%, respectively. Comparatively, the GORE-TEX Stretch Vascular Graft showed primary patency, secondary patency, and limb salvage rates of 71.0%, 91.7%, and 95.8%, respectively. Long-term data are not available regarding improved patency compared to marketed grafts. Safety: Two (2) GORE PROPATEN Vascular Graft subjects experienced a total of two major device-related adverse events, both graft infections. Three (3) GORE-TEX Stretch Vascular Graft subjects experienced a total of four major device-related adverse events, a graft infection with an infected prosthetic mitral valve, a graft infection, and a perigraft hematoma. There were no reported cases of HIT and no unanticipated adverse device effects (UADEs). Survival at 12 months: Kaplan-Meier estimates of survival at 12 months were comparable between treatment groups, 92.5% (95% CI: 84.8%, 96.3%) in the GORE PROPATEN Vascular Graft group and 95.6% (95% CI: 88.7%, 98.3%) in the GORE-TEX Stretch Vascular Graft group. No device-related deaths were reported in the study. IV. PACKAGE HANDLING Store in a cool dry place. This product has an expiration date and should be used before the labeled use by (expiration) date marked on the box. The foil pouch is both a moisture barrier and a sterile barrier. DO NOT use or store the graft if the foil pouch has been compromised. To open the package, peel open the foil pouch and remove the tray. Beginning at one corner, peel back the tray lid and gently remove the graft. Use clean gloves or atraumatic instruments when handling the graft. V. TECHNICAL INFORMATION A. The CBAS Heparin Surface on the GORE PROPATEN Vascular Graft consists of stable, covalent, end-point attached heparin of porcine origin. B. The presence of heparin on the GORE PROPATEN Vascular Graft is not intended to serve as an alternative to the surgeon s chosen intraoperative or postoperative anticoagulation regimens. The physician should consider the need for intraoperative and / or postoperative anticoagulation therapy based on the pharmacological requirements and medical history of the patient. C. In the event of graft occlusion, established vascular prosthesis revision procedures should be considered. Appropriate revision procedure selection should be determined by the physician based on the specific case requirements. D. DO NOT LET THE LUMINAL SURFACE OF THE GORE PROPATEN VASCULAR GRAFT DRY ONCE IT HAS BEEN WETTED. E. With any vascular procedure, the possibility of HIT may exist. The incidence of HIT type II is extremely low in vascular patients receiving heparin over a period of several days. If HIT type II is diagnosed, established procedures for the treatment of this condition, including immediate cessation of systemic heparin administration, should be followed. 1,2 If symptoms persist, or the health of the patient appears compromised, alternative pharmaceutical or surgical procedures, including ligation or removal of the device, may be considered at the discretion of the attending physician. F. The total graft length printed on the package is the usable length when the graft is placed under moderate tension. (Refer to OPERATIVE TECHNIQUES - TENSIONING, Section VII. B.) G. CORONARY ARTERY BYPASS PROCEDURES (Also refer to INDICATIONS FOR USE and CONTRAINDICATIONS) W. L. Gore & Associates, Inc., has insufficient clinical and experimental data upon which to base any conclusion regarding the use of GORE PROPATEN Vascular Grafts in coronary artery bypass procedures. H. AXILLOFEMORAL, FEMOROFEMORAL, and AXILLOBIFEMORAL BYPASS PROCEDURES The success of axillofemoral, femorofemoral, and axillobifemoral bypasses depends in large part on the implantation technique. Specific complications associated with improperly implanted GORE PROPATEN Vascular Grafts in these positions may include suture hole elongation and mechanical disruption or tearing of the graft, suture line, or host vessel. 1

Failure to follow these techniques may result in extreme blood loss, loss of limb function, loss of limb, or death. Although experience indicates that the incidence of these complications is extremely low, the following techniques MUST be employed if your treatment plan includes one of the above procedures: Consider the patient s body weight and posture when determining the lengths of the tissue tunnel and the graft. Drape the patient to allow full movement of the arm, shoulder girdle or legs when determining correct graft length. Avoid protracted hyperabduction of the arm. Prolonged hyperabduction may lead to brachial plexus injury. Allow sufficient length to avoid stressing the axillary or femoral anastomoses throughout the full range of movement of the arm, shoulder girdle, or legs. Surgeons suggest that the graft be placed under both the pectoralis major and pectoralis minor. Cutting the graft slightly longer than necessary has been reported by some surgeons to reduce further the risk of stressing the graft or the anastomoses. For the pre-configured GORE PROPATEN Vascular Graft Removable Ring Axillobifemoral, refer to OPERATIVE TECHNIQUES - GORE PROPATEN VASCULAR GRAFT REMOVABLE RING AXILLOBIFEMORAL, Section VII. E. For the pre-configured GORE PROPATEN Vascular Graft Removable Ring Axillobifemoral, moderately tension each component of the graft separately to avoid inadvertently placing excess tension on the graft suture line at the manufactured anastomosis site. 0-25 RECOMMENDED ANASTOMOTIC PLACEMENT AND ABDUCTION TEST RECOMMENDED ANGLE OF BEVEL An alternative technique reported by some surgeons 3,4 to further avoid stressing the axillary anastomosis is to route the graft parallel and adjacent to the axillary artery posterior to the pectoralis minor muscle for approximately 8-10 cm before forming a gentle curve to its inferior course. GRAFT TO AXILLARY ARTERY END-TO-SIDE ANASTOMOSIS. THE GRAFT IS PLACED PARALLEL TO THE AXILLARY ARTERY POSTERIOR TO THE PECTORALIS MINOR MUSCLE FOR 8 TO 10 CM BEFORE GENTLY CURVING TOWARD THE PROPOSED ANASTOMOTIC SITE. HOLD THE GRAFT AT THE SUTURED ANASTOMOSIS OF THE GRAFT AND TENSION THE LEG OF THE GRAFT. DO NOT TENSION THE GRAFT BY PULLING ON THE LEGS OF THE GRAFT AS DOING SO MAY LEAD TO SUTURE PULLOUT. Correctly bevel the axillary anastomosis. Stress on the graft is minimized when the graft is placed parallel (0 ) to the axillary artery. Therefore, the anastomotic angle should be as small as possible and should not exceed 25 relative to the cut edge of the graft. Anastomose the graft close to the rib cage on the first portion of the axillary artery. Do not place the anastomosis on the third portion of the axillary artery. To aid in proper parallel placement of the graft in relation to the axillary artery, some surgeons 5 have reported the use of an axillary counterincision near the third part of the artery. The axillofemoral portion of the graft should lie in the mid-axillary line to minimize kinking when the patient bends forward at the waist. For the pre-configured GORE PROPATEN Vascular Graft Removable Ring Axillobifemoral, begin implantation by pulling the graft to the axillary counterincision with the use of an appropriate tunneling instrument. The graft should lie in the mid-axillary line to minimize kinking when the patient bends forward at the waist. Pull the graft from the axillary counterincision to the first portion of the axillary artery. The graft must be placed under both the pectoralis major and the pectoralis minor muscles. The anastomosis must be performed in the first portion of the axillary artery, proximal to the thoracoacromial trunk. This entails dissection and proximal control at the axillary-subclavian junction under the clavicle. Correct placement in this area prevents excessive movement of the artery / graft junction. Do not place the anastomosis on the second or third portion of the axillary artery. Rotate the axillary artery with clamps so that the arteriotomy is made on its inferior border, placing the arteriotomy as close as possible to the first rib to minimize subsequent movement. Correctly bevel the axillary anastomosis. Stress on the anastomosis is minimized when the graft is placed parallel to the axillary artery. 2

CAUTION THE PATIENT AGAINST EXTREME OR ABRUPT MOVEMENTS OF THE ARM, SHOULDER, OR LEGS DURING A CONVALESCENT PERIOD OF SIX-TO-EIGHT WEEKS TO ALLOW FOR ADEQUATE HEALING. ROUTINE ACTIVITIES SUCH AS REACHING OUT IN FRONT, RAISING ARMS ABOVE THE SHOULDER LEVEL, THROWING, PULLING, STRIDING, OR TWISTING SHOULD BE AVOIDED. FAILURE TO FOLLOW THESE PROCEDURES MAY RESULT IN EXTREME BLOOD LOSS, LOSS OF LIMB FUNCTION, LOSS OF LIMB, OR DEATH. I. VASCULAR ACCESS PROCEDURES Patients should be carefully monitored when using GORE PROPATEN Vascular Grafts for vascular access. Puncture sites must be adequately separated when repeated needle punctures of the graft are necessary. Multiple punctures in the same area may lead to disruption of the graft material or formation of a perigraft hematoma or pseudoaneurysm. For additional information, refer to the brochure GORE-TEX Vascular Grafts for Hemodialysis: Techniques for the Care and Cannulation of A-V Fistulas, available from W. L. Gore & Associates. If the GORE PROPATEN Vascular Graft with Removable Rings is used for vascular access, the rings must be removed from any cannulation region prior to implant (Reference, OPERATIVE TECHNIQUES - GORE PROPATEN VASCULAR GRAFT WITH REMOVABLE RINGS, Section VII.C.4.). Do not puncture the graft at or near any ringed section. VI. POSSIBLE COMPLICATIONS WITH THE USE OF ANY VASCULAR PROSTHESIS A. Complications which may occur in conjunction with the use of any vascular prosthesis include but are not limited to: redundancy; infection; ultrafiltration or perigraft seroma; thrombosis; mechanical disruption or tearing of the suture line, graft, and / or host vessel; excessive suture hole bleeding; formation of pseudoaneurysms due to excessive, localized, or large needle punctures; or perigraft hematomas. B. A possible complication which may occur in conjunction with the use of any heparin-containing product: HIT type II (see section V. E on previous page). 8. Anastomotic angles vary with the vascular procedure being performed. Use of an appropriate anastomotic angle may minimize undue stresses which may lead to mechanical disruptions of the graft, host vessel, and / or suture lines. 9. Use only nonabsorbable, monofilament sutures, such as GORE-TEX Suture, of a size appropriate for the nature of the reconstruction. Do not use a full radius cutting needle as it may damage the graft. 10. Undue anastomotic bleeding may occur if excessive tension causes suture holes to elongate or tear, if the needle-to-suture diameter ratio is too great, or if gaps occur between the graft and the host vessel. Use appropriate suture placement and bites and avoid undue tension on the suture line. Hemostatic agents such as topical thrombin and Surgicel Absorbable Hemostat may be used to minimize anastomotic bleeding. The manufacturers instructions for these products should be observed. 11. The physician should ensure that the patient has been informed as to appropriate postoperative care. B. OPERATIVE TECHNIQUES - TENSIONING 1. When handling or tensioning the GORE PROPATEN Vascular Graft, avoid using excessive force or high rates of force which could lead to graft disruption. 2. Even though the GORE PROPATEN Vascular Graft affords some extensibility, the graft must still be cut to the correct length. 3. After completing the proximal anastomosis, apply moderate tension to the entire length of the GORE PROPATEN Vascular Graft in order to remove the extensibility. Ensure that moderate tension is transmitted from the distal end of the graft to the proximal (first) anastomosis immediately prior to cutting the graft to length. Blue orientation markers can aid in determining moderate tension. 4. Reasonable assurance of moderate tension is provided when the blue orientation markers, illustrated in the following two figures, change configuration from Figure A to Figure B at the proximal and distal anastomotic sites. VII. OPERATIVE TECHNIQUES A. ALL GORE PROPATEN VASCULAR GRAFT CONFIGURATIONS 1. To avoid damage or contamination, always use clean gloves and atraumatic instruments when handling the GORE PROPATEN Vascular Graft. Always protect the graft from damage by heavy or sharp objects. 2. When applying clamps, care should be taken to avoid mechanical damage to, or disruption of, the graft. Use the appropriate atraumatic or guarded (for example, rubber shod) clamps. Avoid repeated, localized clamping or excessive clamping on any section of the graft. 3. It is not necessary to preclot the GORE PROPATEN Vascular Graft. 4. Blood or plasma leakage may occur if appropriate handling techniques are not observed. Do not allow the graft to contact organic solvents such as alcohol or Betadine Solution. Avoid excessive manipulation of the graft in contact with tissue fluids or blood, as well as forcing irrigating solutions through the graft wall or filling the graft with blood prior to passing it through the tissue tunnel. 5. The correct graft length for each procedure must be carefully determined, taking into consideration the patient s body weight and posture, and the range of motions likely to be encountered across the anatomical area of the graft implantation. The graft should never be too short. 6. Failure to correctly cut the GORE PROPATEN Vascular Graft may damage the outer reinforcing layer and may result in aneurysmal dilatation or reduced suture retention strength. When cutting the graft, gently pull the graft taut and determine the correct length. Cut the graft with a sharp surgical instrument. DO NOT PULL OR PEEL THE OUTER REINFORCING LAYER FROM ANY AREA OF THE GRAFT. IF THE OUTER REINFORCING LAYER BECOMES FRAYED AT THE END OF THE GRAFT, CAREFULLY TRIM THAT PORTION OF THE GRAFT WITH A SHARP SURGICAL INSTRUMENT. 7. Use a tunneler to create a tissue tunnel that closely approximates the graft diameter. A tissue tunnel that is too loose may result in delayed or insufficient perigraft tissue attachment, and may be a contributing factor to perigraft seroma formation. 3 Figure A RELAXED Figure B MODERATE TENSION C. OPERATIVE TECHNIQUES - GORE PROPATEN VASCULAR GRAFT WITH REMOVABLE RINGS 1. GORE PROPATEN Vascular Grafts with Removable Rings consist of a reinforced expanded PTFE Vascular Graft and an additional thin film to which rings are attached. This design allows the surgeon to remove rings without damaging or compromising the mechanical integrity of the graft. Following ring removal, portions of the additional thin film are normally visible on the graft and removed ring(s). 2. Use a tunneler to create a tissue tunnel that closely approximates the graft diameter, and allows free passage of FEP rings. A tissue tunnel that is too tight may disrupt ring attachment. 3. To prevent ring detachment when passing a graft through an incision, avoid catching the rings on the edge of the incision or tunneler. 4. RING REMOVAL: To avoid damaging the graft, do NOT use surgical blades or sharp instruments. Care should be taken not to damage the reinforcing layer immediately beneath the additional thin film to which the rings are attached. Following ring removal, portions of the additional thin film are normally visible on the graft and removed ring(s). IF THE REINFORCING LAYER APPEARS FRAYED OR DAMAGED, THAT SEGMENT OF THE GRAFT SHOULD NOT BE USED. To remove rings from the end of a ringed section or before suturing: Hold the graft firmly with one gloved hand. With the other hand, gently grasp and lift a ring(s) with gloved fingers or atraumatic instrument and slide it off the end of the graft. To remove rings from within a ringed section or after suturing: Hold the graft firmly with one gloved

hand. With the other hand, loosen a ring(s) by gently grasping and lifting with an atraumatic instrument. Carefully cut each ring with blunt-nosed scissors and peel off the severed ring(s). 5. Reference, CONTRAINDICATIONS, Section II. B.; TECHNICAL INFORMATION, Section V. F.,G., and H.; and, OPERATIVE TECHNIQUES: ALL GORE PROPATEN VASCULAR GRAFT CONFIGURATIONS, Section VII. A. D. OPERATIVE TECHNIQUES - GORE PROPATEN VASCULAR GRAFT WITH INTEGRATED RINGS 1. GORE PROPATEN Vascular Grafts with Integrated Rings consist of a reinforced eptfe GORE-TEX Vascular Graft with integrated eptfe radial support within the wall of the graft. 2. The eptfe radial support is NOT removable. The GORE PROPATEN Vascular Graft with Integrated Rings is a unibody design incorporating continuous eptfe microstructure between radial support and non-radial support sections of the graft. Attempting to remove the radial support will damage the graft. 3. The eptfe radial support sections of the GORE PROPATEN Vascular Graft with Integrated Rings can be incorporated into the anastomosis. The integrated radial support can be cut and sewn through using appropriate cutting and suturing techniques. Reference, OPERATIVE TECHNIQUES: ALL GORE PROPATEN VASCULAR GRAFT CONFIGURATIONS, Section VII. A. 4. When applying clamps, care should be taken to avoid mechanical damage or disruption to the GORE PROPATEN Vascular Graft with Integrated Rings. Use the appropriate atraumatic or guarded (for example, rubber shod) clamps. Avoid repeated, localized clamping or excessive clamping on any section of the graft. 5. Reference, Technical Information, Section V. G., Coronary Artery Bypass Procedures, and "OPERATIVE TECHNIQUES: ALL GORE PROPATEN VASCULAR GRAFT CONFIGURATIONS, Section VII. A. E. OPERATIVE TECHNIQUES - GORE PROPATEN VASCULAR GRAFT REMOVABLE RING AXILLOBIFEMORAL 1. The GORE PROPATEN Vascular Graft Removable Ring Axillobifemoral is not elastic. The graft should never be too short. 2. Even though the GORE PROPATEN Vascular Graft Removable Ring Axillobifemoral affords some extensibility, the graft must still be cut to the correct length. 3. Failure to correctly cut the GORE PROPATEN Vascular Graft Removable Ring Axillobifemoral may damage the outer reinforcing layer and may result in aneurysmal dilatation or reduced suture retention strength. When cutting the graft, gently pull the graft taut and determine the correct length. Cut the graft with a sharp surgical instrument. DO NOT PULL OR PEEL THE OUTER REINFORCING LAYER FROM ANY AREA OF THE GRAFT. IF THE OUTER REINFORCING LAYER BECOMES FRAYED AT THE END OF THE GRAFT, CAREFULLY TRIM THAT PORTION OF THE GRAFT WITH A SHARP SURGICAL INSTRUMENT. 4. Reference, TECHNICAL INFORMATION, Section V. H, AXILLOFEMORAL, FEMOROFEMORAL, AND AXILLOBIFEMORAL BYPASS PROCEDURES. 5. Reference, OPERATIVE TECHNIQUES: ALL GORE PROPATEN VASCULAR GRAFT CONFIGURATIONS, Section VII. A.; and, OPERATIVE TECHNIQUES - GORE PROPATEN VASCULAR GRAFT WITH REMOVABLE RINGS, Section VII. C. VIII. STERILITY GORE PROPATEN Vascular Grafts are supplied STERILE unless the integrity of the package has been compromised. The sterilization method is marked on the box. Sterility will be maintained until the labeled use by (expiration) date marked on the box. IX. RESTERILIZATION DO NOT RESTERILIZE THE GORE PROPATEN VASCULAR GRAFT. REFERENCES 1. Linkins LA, Dans AL, Moores LK, Bona R, Davidson BL, Schulman S, Crowther M; American College of Chest Physicians. Treatment and prevention of heparin-induced thrombocytopenia: antithrombotic therapy and prevention of thrombosis, 9th ed: American College of Chest Physicians Evidence-Based Clinical Practice Guidelines. Chest 2012;141(2)Supplement:e495S-e530S. 2. Warkentin TE. Heparin-coated intravascular devices and heparin-induced thrombocytopenia. In: Warkentin TE, Greinacher A, eds. Heparin-Induced Thrombocytopenia. 5th ed. New York, NY: Informa Healthcare USA; 2012;(20):573-590. 3. Landry GJ, Moneta GL, Taylor LM Jr, Porter JM. Axillobifemoral bypass. Annals of Vascular Surgery 2000;14(3):296-305. 4. Taylor LM Jr, Park TC, Edwards JM, et al. Acute disruption of polytetrafluoroethylene grafts adjacent to axillary anastomoses: a complication of axillofemoral grafting. Journal of Vascular Surgery 1994;20(4):520-528. 5. Bunt TJ, Moore W. Optimal proximal anastomosis / tunnel for axillofemoral grafts. Journal of Vascular Surgery 1986;3(4):673-676. DEFINITIONS Authorised Representative in the European Community Batch Code Catalogue Number Caution CAUTION: USA Federal Law restricts the sale, distribution, or use of this device to, by, or on the order of a physician. Consult Instructions for Use Date of Manufacture 2 STERILIZE Do Not Resterilize Do Not Reuse Do Not Use if Package is Damaged Keep Dry Manufacturer Serial Number Use By Sterile Sterilized using Ethylene Oxide Store in a Cool Place Angle AXL Axillobifemoral Diameter Fibril Length 25 Microns (Nominal) Fibril Length Radial Support 5 Microns (Nominal) IR Integrated Rings Length Non-Removable Rings Removable Rings Ring Section Standard Wall Thin Wall 4

20027094 Manufacturer W. L. GORE & ASSOCIATES, INC. 1505 North Fourth Street Flagstaff, Arizona 86004 UNITED STATES Order Information: Tel.: 928.526.3030 Tel.: 800.528.8763 Technical Information: Tel.: 928.779.2771 Tel.: 800.437.8181 For international contact and additional product information, visit www.goremedical.com GORE, GORE-TEX, ACUSEAL, PROPATEN, and designs are trademarks of W. L. Gore & Associates. CBAS is a trademark of Carmeda AB, a wholly owned subsidiary of W. L. Gore & Associates, Inc. SURGICEL is a trademark of Johnson & Johnson, Inc. BETADINE is a trademark of Purdue Fredrick Company. 2001, 2005, 2006, 2009-2012, 2014-2016 W. L. Gore & Associates, Inc. AUGUST 2016 Printed on recyclable paper 20027095