The BD Viper with XTR technology for STI testing - reliable, accurate and highly efficient

Similar documents
Reliable, cost-effective CT/GC testing For labs with low to medium throughput needs. The BD ProbeTec ET System

New CT/GC Tests. CDC National Infertility Prevention Project Laboratory Update Region II May 13-14, 2009

Technical Bulletin No. 98b

CDC Laboratory Update

Chlamydia Rapid Screen Test (RAP-2858) RUO in the USA. Revised 28 Jul 2006

Medicaid Family Planning Waiver Services CPT Codes and ICD-10 Diagnosis Codes

7/13/2018. NEW TESTS - Please update your EMR catalog with those appropriate to your practice

The objectives of this presentation are; to increase awareness of the issue of antimicrobial resistant gonorrhea, and to inform primary care and

ProbeTec ET Neisseria gonorrhoeae Amplified DNA Assay

Xpert CT/NG. Detect it in here. Stop it out there. Three targets, 90 minutes. No repeat testing. Xpert CT/NG. Xpert. A better way.

4. RED AND BLUE TOP COLLECTION SWABS WILL NO LONGER BE SUPPLIED FOR BACTERIAL CULTURE

CHLAMYDIA/GC AMPLIFIED RNA ASSAY

RealLine Mycoplasma genitalium Str-Format

About HPV. Human papillomavirus (HPV) is a group of viruses that are extremely common worldwide. Theree are more than 100 types of HPV, of which at

Index. Infect Dis Clin N Am 19 (2005) Note: Page numbers of article titles are in boldface type.

Industry Sponsored Symposia. Québec City, CANADA JULY 10 TO 13,

Quarterly laboratory and pathology update from Legacy Laboratory Services in collaboration with Cascade Pathology

Controls for Chlamydia trachomatis and Neisseria gonorrhoea

BLOOD IS COMPLEX ANALYZING IT SHOULDN T BE DxH 500 * *Not available for sale in the U.S.

Lymphogranuloma Venereum (LGV) Surveillance Project

2014 CDC GUIDELINES CHLAMYDIA & GONORRHEA DIAGNOSTICS. Barbara Van Der Pol, PhD, MPH University of Alabama at Birmingham

Cotinine (Mouse/Rat) ELISA Kit

Biology 3201 Unit 2 Reproduction: Sexually Transmitted Infections (STD s/sti s)

Herpes Simplex Virus 2 IgG HSV 2 IgG

See external label 96 tests HSV 2 IgA. Cat #

Scottish Bacterial Sexually Transmitted Infections Reference Laboratory (SBSTIRL) User Manual Jan 2018

6/11/15. BACTERIAL STDs IN A POST- HIV WORLD. Learning Objectives. How big a problem are STIs in the U.S.?

Trichomonas Time to Know the Facts

New diagnostic tests for sexually transmitted infections. Jens Van Praet 30/11/2018

Menu and flexibility with the QIAscreen HPV PCR Test

GeneXpert System. On-Demand Molecular Testing for the Physician Office Laboratory

Rotavirus Test Kit. Instructions For Use. Format: Cassette Specimen: Fecal Extract Catalog Number: VEL-001-ROTA

QUICK REFERENCE INSTRUCTIONS For use with Sofia and Sofia 2. Rx only

Controls for Chlamydia trachomatis and Neisseria gonorrhoea

USER GUIDE FOR SPECIMEN COLLECTION

How is it transferred?

GUIDELINES FOR THE MANAGEMENT OF SEXUALLY TRANSMITTED INFECTIONS

Processing of female genital specimens at Labtests and Northland Pathology Laboratory

For purification of viral DNA and RNA from a wide range of sample materials

Guidance on the use of molecular testing for Neisseria gonorrhoeae in Diagnostic Laboratories 2011

SEXUAL HEALTH LAB PRODUCTS

Herpes Simplex Virus 2 IgM HSV 2 IgM

Human HBcAb IgM ELISA kit

STI control. Dr. Jane Morgan Hamilton Sexual Health Clinic

APTIMA Combo 2 Assay (PANTHER System)

Women s Sexual Health: STI and HIV Screening. Barbara E. Wilgus, MSN, CRNP STD/HIV Prevention Training Center at Johns Hopkins

Murex Chlamydia Verification Kit

Chlamydia trachomatis (CHLa)Test Kit

QUICK REFERENCE INSTRUCTIONS

OAML Guideline on the Investigation of Genital Tract Infections November, 2015

RealLine HIV qualitative Str-Format

Sexually Transmi/ed Diseases

H. pylori Antigen ELISA Kit

QUICK REFERENCE INSTRUCTIONS For use with Sofia only.

The Impact of Sexually Transmitted Diseases(STD) on Women

DX CT/NG/MG AUTO ASSAY

Chlamydia Trachomatis IgA

STI Multiplex Array. Rapid, simultaneous detection of 10 sexually transmitted infections

STI Multiplex Array. Rapid, simultaneous detection of 10 sexually transmitted infections

STIs- REVISION. Prof A A Hoosen

Genital Chlamydia and Gonorrhea Epidemiology, Diagnosis, and Management. William M. Geisler M.D., M.P.H. University of Alabama at Birmingham

Family Planning Title X Chlamydia Screening Quality Improvement Project

Sexually Transmitted Infections in HSV-2 Seropositive women in Sub- Saharan Africa HPTN 039

Guidelines for the Laboratory Detection of Chlamydia trachomatis, Neisseria gonorrhoeae and Treponema pallidum Testing

NIH Public Access Author Manuscript Sex Transm Infect. Author manuscript; available in PMC 2013 June 04.

Outline. HIV and Other Sexually Transmitted Infections. Gonorrhea Epidemiology. Epidemiology 11/2/2012

17a. Sexually Transmitted Diseases and AIDS. BIOLOGY OF HUMANS Concepts, Applications, and Issues. Judith Goodenough Betty McGuire

HSV-1 IgM ELISA. Catalog No (96 Tests) For Research Use Only. Not for use in Diagnostic Procedures.

Rubella virus IgG ELISA Kit

DETECTION OF NEISSERIA GONORRHOEAE USING MOLECULAR METHODS

HBeAg and HBeAg Ab ELISA Kit

See external label 2 C-8 C 96 tests CHEMILUMINESCENCE. CMV IgG. Cat # Step (20-25 C Room temp.) Volume

ENG MYCO WELL D- ONE REV. 1.UN 29/09/2016 REF. MS01283 REF. MS01321 (COMPLETE KIT)

Sexually Transmitted Infections. Naluce Manuela Morris, MPH, CHES

ONLINE SUPPLEMENTARY MATERIALS: FILE 1

The clearest path to the most meaningful results. The cobas HPV Test delivers clinical value with workflow efficiencies every step of the way

Be sure! Your Power for Health. PelvoCheck CT/NG Your test kit for Chlamydia trachomatis screening and Neisseria gonorrhoeae infections

RealLine HCV Qualitative Str-Format

RealLine HBV / HCV / HIV Str-Format

Norgen s HIV Proviral DNA PCR Kit was developed and validated to be used with the following PCR instruments: Qiagen Rotor-Gene Q BioRad T1000 Cycler

Norgen s HIV proviral DNA PCR Kit was developed and validated to be used with the following PCR instruments: Qiagen Rotor-Gene Q BioRad icycler

Human Cytomegalovirus IgM ELISA Kit

CYTOMEGALOVIRUS (CMV) IgM ELISA Kit Protocol

Clinical Policy Title: Vaginitis diagnosis

Professor Jonathan Ross

EpiQuik Circulating Acetyl Histone H3K18 ELISA Kit (Colorimetric)

RealLine HIV quantitative Str-Format

For in vitro Veterinary Diagnostics only. Kylt Rotavirus A. Real-Time RT-PCR Detection.

Influenza A IgG ELISA

Disclosures. STD Screening for Women. Chlamydia & Gonorrhea. I have no disclosures or conflicts of interest to report.

Chlamydia Trachomatis IgG ELISA Kit

Toxoplasma gondii IgM ELISA Kit

Toxoplasma gondii IgM ELISA Kit

Sexually Transmitted Infection Treatment and HIV Prevention

Measures 100 ppm to 100% water content. Precision titrant delivery system. Anti-diffusion burette tip. Built-in stirrer

BD Affirm VPIII Microbial Identification Test

BD Affirm VPIII Microbial Identification Test VAGINAL INFECTIONS:

STI Diagnostics Redesign. HVS and Chlamydia Resource Pack

SIV p27 Antigen ELISA Catalog Number:

Extragenital Chlamydia and Gonorrhea. Angel Stachnik, MPH Sr. Epidemiologist Office of Epidemiology and Disease Surveillance

Transcription:

Simply the most comprehensive solution The BD Viper with XTR technology for STI testing - reliable, accurate and highly efficient

2

Summary Introduction p. 5 The BD ProbeTec Q x Amplified STI DNA Assays: Accurate and Relevant Clinical Answers For Your Patients BD ProbeTec CT Q x Amplified DNA Assay BD ProbeTec GC Q x Amplified DNA Assay BD ProbeTec Herpes Simplex Viruses (HSV 1 & 2) Q x Amplified DNA Assay BD ProbeTec Trichomonas vaginalis Q x Assay The BD Viper System with XTR Technology: Your Solution for Efficient and Worry Free STI Testing BD Viper : System Overview and Data Management p.6-7 p.6-7 p.8-9 p.10-11 p.12-13 p.14-15 Catalog numbers p.16 3

4

Sexually transmitted infections (STI) have been known since antiquity. Gonorrhoea was decribed by the ancient Egyptians, and was recognized by Greek and Roman medical writers. STI incidence rates remain high in most of the world, despite diagnostic and therapeutic advances that can cure most patients. According to the 2012 Annual Epidemiology Report of the European Center for Disease Control, Chlamydia trachomatis (CT) is the most frequently reported sexually transmitted infection in EU/EEA countries, with over 340000 cases reported in 2009. * Chlamydia infections appear to have reached a plateau in 2010 in Europe while gonorrhoea shows a slight decrease over the past decade. The real number of infections might be even higher since many are not diagnosed due to absence of symptoms, lack of appropriate methods or because of the diversity in the healthcare and reporting systems across Europe. Yet increasing levels of infection across Europe pose a significant public health challenge. In this brochure, BD presents a range of solutions to accurately screen for and to diagnose sexually transmitted infections to support the fight against these diseases. * ECDC Annual Epidemiological Report 2012 ** ECDC STI surveillance report 1990-2009 5

The BD ProbeTec Q x Amplified STI DNA Assays: Accurate and Trust in results BD has implemented a broad range of measures to provide you with the most reliable test results to serve your patients needs: Extraction control included in each sample ensures proper functionality of the reagents Positive and negative controls included in each run confirm successful operation Ready-to-use reagents exclude any errors during reagent preparation Clear yes/no results avoid patient recalls and retesting All assays are CE marked according to the IVD Directive and FDA cleared BD ProbeTec CT Q x Amplified DNA Assay Chlamydia has a rate of 186 per 100,000 population in Europe. 75 % of all cases are reported in young people between 15 and 24 years of age even with a notification rate of 821 per 100,000.* The BD ProbeTec CT Q x Amplified DNA Assay: Is suitable for all screening and diagnosis approaches in Europe through its very broad range of approved sample types including patient-collected samples Provides excellent sensitivity and specificity resulting in a high PPV even in populations with low infection prevalence Reliably detects the Swedish variant of Chlamydia trachomatis BD ProbeTec GC Q x Amplified DNA Assay Gonorrheae is the second most commonly reported STI in Europe after CT with a rate of 10.4 per 100,000. More than 25 % of all infections are among men who have sex with men and more than 40 % of cases are in young people below 25 years of age.* The BD ProbeTec GC Q x Amplified DNA Assay: Is suitable for all screening and diagnosis approaches in Europe through its very broad range of approved sample types including patient-collected samples Reliably detects Neisseria gonorrhoeae strains which lack or have significant deletions inthe pora pseudogene. Gonococcal antimicrobial resistance shows a significant increase. BD offers plated media and the respective discs for resistance testing. * ECDC Annual Epidemiological Report 2012. 6

Relevant Clinical Answers For Your Patients CT Q x and GC Q x assay specifications The BD ProbeTec CT Q x Amplified DNA and GC Q x Amplified DNA Assays, when tested with the BD Viper System in Extracted Mode, uses Strand Displacement Amplification technology for the direct, qualitative detection of Chlamydia trachomatis and Neisseria gonorrhoeae DNA in clinician-collected female endocervical and male urethral swab specimens, patient-collected vaginal swab specimens (in a clinical setting), and male and female urine specimens. The assay is also intended for use with gynecological specimens collected in BD SurePath Preservative Fluid or PreservCyt Solution using an aliquot that is removed prior to processing for either the BD SurePath or ThinPrep Pap test. The assay is indicated for use with asymptomatic and symptomatic individuals to aid in the diagnosis of chlamydial urogenital disease. CT Q x Amplified DNA Assay GC Q x Amplified DNA Assay Sensitivity Specificity Sensitivity Specificity Urine and Swabs 94.5% 98.9% 99.3% 99.4% LBC 94.1% 99.8% 95.3% 99.95% Swab specimen type to be processed Temperature Condition for Transport to Test Site and Storage Process Specimen According to Instructions Urine Specimen Type to be Processed Urine Handling Options Prior To Transfer To Q x UPT Temperature Condition for Storage and Transport to Test Site Process Specimen According to Instructions Female endocervical swab specimen / Male urethral swab specimen Dry vaginal swab specimen (Collection site) Vaginal swab specimen Expressed vaginal swab specimen (Test site) 2-30 C -20 C 2-30 C -20 C 2-30 C -20 C Within 30 days Within 180 days Q x UPT Express and process within 14 days Store urine specimen at 2-30 C and transfer to Q x UPT within 8 h or Store urine specimen at 2-8 C and transfer to Q x UPT within 24 h or Transfer to Q x UPT immediately Express and process within 180 days Within 30 days of expression NEAT Within 180 days of expression 2-8 C 2-30 C -20 C 2-8 C 2-30 C -20 C Within 30 days after transfer to Q x UPT Within 180 days after transfer to Q x UPT Within 7 days Within 30 h Within 180 days LBC Specimen Type to be processed Storage and Transport of Specimens Transferred to the LBC Specimen Dilution Tube 2-30 C -20 C Process Specimen According to the instructions 30 days 30 days 7

The BD ProbeTec Q x Amplified STI DNA Assays: Accurate and BD ProbeTec Herpes Simplex Viruses (HSV 1 & 2) Q x Amplified DNA Assay Genital herpes is caused by either herpes simplex virus type 1 (HSV-1) or type 2 (HSV-2) but, globally, the large majority of cases are caused by HSV-2. Although many infections are asymptomatic, genital lesions can be very painful. The virus can also be passed from mother to child during birth. 80% of infants with disseminated disease die, and those who do survive are often brain damaged.* The BD ProbeTec Herpes Simplex Viruses (HSV 1 & 2) Q x Amplified DNA Is a NAAT test which is the method of choice for diagnosis of genital HSV infection as recommended by the European Guidelines from 2010.** Accurately diagnoses HSV 1 and/or 2 infection even at late stages of presentation. Detects HSV 1 and HSV 2 in a single test to guide counselling and management. * Bulletin of the World Health Organization 2008;86:805 812. ** Int J STD AIDS, 2011 Jan; 22 (1): 1-10 8

Relevant Clinical Answers For Your Patients Herpes Simplex Viruses (HSV 1 & 2) Q x assay specifications The BD ProbeTec Herpes Simplex Viruses (HSV 1 & 2) Q x Amplified DNA Assays (HSV Q x Assays), when tested with the BD Viper System in Extracted Mode, use Strand Displacement Amplification technology for the direct, qualitative detection and differentiation of Herpes Simplex virus type 1 (HSV1) and Herpes Simplex virus type 2 (HSV2) DNA in clinician-collected external anogenital lesion specimens. The assays are indicated for use with symptomatic individuals to aid in the diagnosis of anogenital HSV1 and HSV2 infections. The assay is intended for use with the BD ProbeTec Q x Collection Kit for Endocervical or Lesion Specimens, BD Universal Viral Transport Medium (UVT) (3 ml) with polyester-fiber-tip swab collection kit or identical Copan Universal Transport Medium and polyester-fiber-tip swab collection kit. HSV 1 Q x Amplified DNA Assay HSV 2 Q x Amplified DNA Assay Sensitivity Specificity Sensitivity Specificity UVT in Q x Swab Diluent 96.8% 97.6% 98.4% 83.7% Q x Swab Diluent 96.7% 95.1% 98.4% 80.6% BD ProbeTec Q x Collection Kit for Endocervical or Lesion Specimens Temperature Condition for Transport to Test Site and Storage 2-30 C -20 C Process Specimen According to Instructions 14 days 120 days UVT Specimen Temperature Condition for Transport to Test Site and Storage 20-25 C 2-8 C -70 C Process Specimen According to Instructions Aliquot and prewarm within 48 h Aliquot and prewarm within 14 days Aliquot and prewarm within 120 days UVT Specimen Transferred into Q x Swab Diluent Temperature Condition for Transport to Test Site and Storage 15-30 C 2-8 C -20 C Process Specimen According to Instructions Pre-warm within 24 h after aliquottlng Pre-warm within 14 days Pre-warm within 120 days 9

The BD ProbeTec Q x Amplified STI DNA Assays: Accurate and BD ProbeTec Trichomonas vaginalis Q x Assay Vaginal trichomoniasis in women has been associated with adverse pregnancy outcomes, particularly premature rupture of membranes, preterm delivery, and low birth weight. It can increase a woman s susceptibility to HIV infection, and may also increase the likelihood of HIV transmission to sex partners. However, further research is needed to confirm these associations and to prove them to be causal.* The BD ProbeTec Trichomonas vaginalis Q x Assay: Is a NAAT test which provides superior sensitivity and specificity over the existing detection methods, i.e. microscopy or culture. Allows you to run studies with an approved and highly accurate diagnostic test * Sherrard et al., Int J STD AIDS August 2011 22:421 429. 10

Relevant Clinical Answers For Your Patients TV Q x assay specifications The BD ProbeTec Trichomonas vaginalis (TV) Q x Amplified DNA Assay, when tested with the BD Viper System in Extracted Mode, uses Strand Displacement Amplification technology for the direct, qualitative detection of Trichomonas vaginalis DNA in clinician-collected female endocervical swab specimens, patient-collected vaginal swab specimens (in a clinical setting), and female urine specimens. The assay is indicated for use with asymptomatic and symptomatic females to aid in the diagnosis of trichomoniasis. TV Q x Amplified DNA Assay Sensitivity Specificity Neat Urine 95.5% 98.7% Vaginal Swab Specimen 98.3% 90.0% Endocervical Swab Specimen 96.5% 99.7% Neat urine stability 2-8 C 2-30 C -20 C 7 days 24 hours 14 days Vaginal Swab Specimens stability Expressed vaginal swab specimens Dry vaginal swab specimens (collection site) (Test site) 2 8 C 30 C -20 C 2 30 C -20 C Express and process within 14 days Express and process within 3 days Within 180 days Within 30 days of expression Within 180 days of expression Endocervical swab specimens stability 2 30 C -20 C Within 30 days Within 180 days 11

The BD Viper System with XTR Technology: Your Solution for Most efficient use of the system Single unit dose reagents - just as many as you need Free combination of sample types Flexible combination of all parameters - all in one run: -CT -GC -TV -HSV1&2 - CT/GC -CT/GC,HSV1&2 - CT/GC/TV - CT/TV - GC/TV -TV,CT - TV, GC - TV, CT/GC -TV,HSV1&2 - TV, CT/GC, HSV 1 & 2 -TV,CT,HSV1&2 -TV,GC,HSV1&2 Fast, actionable results 10 min set-up time only 2 hrs 40 min for the first 184 CT/GC results 1 hrs 40 for the following 184 CT/GC results 736 CT/GC results within 9.5 hrs Clear yes/no results no equivocal zone Minimum reagent storage and space requirements Few ready-to-use reagents Reagent storage at room temperature BD FOX Extractor Module: Holds 96 single-dose BD FOX extraction tubes and permanent magnet assembly for on-board DNA extraction. Sample Processing Station: Up to 96 specimens, including controls, can be loaded for walk-away capability. 12

Efficient and Worry Free STI Testing Safe waste management Liquid waste is automatically neutralised and collected in waste bottle Pipette tips are automatically discarded and collected in waste box Worry-free and most efficient operation No reagent preparation required Fully integrated workflow covering sample extraction, amplification and detection Full walk-away operation Pierceable caps avoid manual opening of sample tubes Patient Sample Identification Location: a membrane switch pad records the location of each sample tube. Maximize your efficiency Use BD S LEAN expertise to optimize your workflow and to compare to existing solution Lowest maintenance required LIS compatibility Amplification/Detection Staging Station: Up to two amplification microwell plates can be incubated for real-time amplification and detection. Priming Station: Two heaters incubate up to two priming microwell plates for hybridization of primers. Pipettor Head: For consumable check, fluid volume transfer, and microwell plate sealing. 13

14 All in one run Comprehensive STI testing with proven DNA amplification technology

System Overview High Throughput System Continuous batching, batch size 96 specimens 2 hours and 40 minutes for the first 184 CT/GC results 184 CT/GC results every 1 hour 40 minutes following the first results Amplification and Detection Technology Strand displacement amplification with real-time amplification and detection Contamination Prevention Closed solid barrier amplification system Waste Management Solid (disposable tips) and neutralized liquid waste Specimen Handling Specimen Collection Type Vaginal & endocervical swabs, urethral swabs, urine, liquid-base cytology (LBC). All collection devices utilize pierceable caps during processing On-Board Sample Capacity 96 samples including controls per run Patient Sample Identification Location A membrane switch pad records the location of the tube. Capacity to read multiple barcode configurations: 2 of 5, code 39, code 128, codabar Sample Dispensing System 6-station pipettor with liquid-level sensing Sample Volume 800 μl Reagent Handling Reagent Format Up to 96 microwells, ready-to-use reagents BD ProbeTec Q x Reagent Stability 18 months, 6 weeks after opening at 2 33 C Physical Dimensions Height 80 in. (203cm) Width 75 in. (191cm) Depth 42 in. (107cm) Weight 1,535 lb (698kg) Optical Readers 2 optical fluorescence readers Data Management Operating Computer VNS-786 running VxWorks 5.5.1 Host Interface LIS-RS-232 Serial ASTM 1381/1394 Data Storage Stores up to 30 runs, capacity to log up to 29 runs in advance Environmental Requirements System Operating Temperature Range 64.4 91.4 F (18 33 C) Ambient Humidity 20% 85% RH non-condensing Noise Specification Less than 65 dba Heat Dissipation 2048 BTU/hr. (600 watt hour) Location Level surface, no direct heat Electrical Requirements Input Voltage 208 240 VAC (single phase line NEMA L6-20P twist lock plug) Input Current 20 Amp Line Frequency 50 60 Hz (±3 Hz) Power Consumption <3500 watts UPS 2.1 to 3.6 KVA Lysing Heater Power Requirements 108 132 VAC/50 60 HZ (220 240 VAC/50 HZ) Operating Temperature 64.4 F 91.4 F (18 C 33 C) Operating Humidity 20% 85% RH non-condensing Operating Altitude 0 6,562 ft. (2,000 m) 15

Catalog Numbers Description 441091 BD Viper with XTR Technology 441126 BD ProbeTec Chlamydia trachomatis Q x Reagent Pack, 1152 tests 441124 BD ProbeTec Neisseria gonorrhoeae Q x Reagent Pack, 1152 tests 441125 Control Set for the BD ProbeTec Chlamydia trachomatis/neisseria gonorrhoeae (CT/GC) Q x Amplified DNA Assays 441917 BD ProbeTec Trichomonas vaginalis (TV) Q x Reagent Pack, 1152 tests 443433 BD ProbeTec Trichomonas vaginalis (TV) Q x Reagent Pack, 384 tests 441925 Control Set for the BD ProbeTec Chlamydia trachomatis / Neisseria gonorrhoeae / Trichomonas vaginalis (CT/GC/TV) Q x Amplified DNA Assays 441749 BD ProbeTec Herpes Simplex Viruses (HSV 1 & 2) Q x Reagent Pack, 94 tests 441748 Control Set for the BD ProbeTec Herpes Simplex Viruses (HSV1&2) Q x Amplified DNA Assays 441128 BD Viper Extraction Reagent and Lysis Trough 441129 BD FOX Extraction Tubes 441354 BD Viper Neutralization Pouch 440752 Microwell Package for the BD Viper System 440724 BD Viper Pipette Tips 441391 BD Viper Trash Bags 441392 BD Viper Trash Box 441853 Accessory Kit for use on the BD Viper System (Extracted Mode) 441358 Male Urethral Specimen Collection Kit for the BD ProbeTec Q x Amplified DNA Assays 441357 BD ProbeTec Q x Collection Kit for Lesion or Endocervical Specimens 441122 Vaginal Specimen Transport for the BD ProbeTec Q x Amplified DNA Assays 441361 Swab Diluent for the BD ProbeTec Q x Amplified DNA Assays 441360 Specimen Tubes and Caps for use on the BD Viper (Extracted Mode) 441359 Caps for the use on the BD Viper (Extracted Mode) 441362 BD Urine Preservative Transport for the BD ProbeTec Q x Amplified DNA Assays 441444 441443 Liquid Based Cytology Specimen (LBC) Dilution Tubes for the BD ProbeTec Q x Amplified DNA Assays Liquid Based Cytology Specimen (LBC) Dilution Tube Caps for the BD ProbeTec Q x Amplified DNA Assays BD, BD Logo and all other trademarks are the property of Becton, Dickinson and Company. 2013 BD. XEUR5233-13. Link to Business. BD Diagnostics Tullastrasse 8-12 69126 Heidelberg Germany Tel. (49) 6221 305 0 Fax (49) 6221 305 604 www.bd.com/europe/ds