SURGICAL PROCEDURES FOR ROXOLID IMPLANTS

Similar documents
Straumann Guided Adapter. Basic information on. the Straumann Guided Adapter

Straumann Dental Implant System. Fax Order Form Collection.*

Guidance for. implant removal. Straumann Dental Implant System

Straumann Basic Guided Surgery Cassette. More than a simple cassette. A smart Guided Surgery solution.

Basic Information on Straumann Guided Surgery. Straumann Dental Implant System

Basic information on the. surgical procedures. Straumann Dental Implant System

Straumann Dental Implant System Basic Information. Technical Information

More than a short implant.

straumann Guided surgery Access to the Digital Experience

Restoring Straumann implants. with Locator abutments.

Straumann ProClean Cassette. Basic Information on the

More than a Ti-base. Your trusted link between implant and restoration. Straumann Variobase C. Variobase for CEREC becomes Variobase C

Surgical Guide Core Products

PROSTHETIC EFFICIENCY. Straumann Angled Solutions (AS) Flexibility and precision from a different angle

ß For cement-retained crowns and bridges. Note: synocta cementable abutments. ß Can be especially helpful with large multi-unit cases Note:

Basic information on the surgical procedures for the. Straumann Bone Level Tapered Implant

Straumann Dental System Indication-based prosthetic workflow. Technical Information

Product Information. Straumann Novaloc. A reliable connection that endures.

Basic information on the surgical and prosthetic procedures

STRAUMANN DENTAL IMPLANT SYSTEM RESToRATIVE SELECTION GUIDE

Service Set Training Presentation English. André Breisinger BU Prosthetics

Basic information on the surgical procedures for the. Straumann Bone Level Tapered Implant

STEP-BY-STEP INSTRUCTIONS ON TEMPORARY ABUTMENTS. Straumann Temporary Abutments, VITA CAD-Temp

STRAUMANN DENTAL IMPLANT SYSTEM RESToRATIVE SELECTION GUIDE

1 mm 2 mm 3 mm 4 mm 5 mm 6 mm

PROSTHETIC EFFICIENCY. Straumann Variobase Beyond a common Ti-base. Efficiency and flexibility in balance.

synocta Meso abutment for cement-retained restorations PROSTHETICS Step-by-step instructions

INSTRUCTIONS FOR USE STRAUMANN VARIOBASE ABUTMENT. Straumann Variobase Abutment

More than pure esthetics. The natural and strong solution.

The difference is obvious. Original components by Straumann

NEODENT GUIDED SURGERY

4766 Research Dr. San Antonio, TX insightdentalsystems.com

SwissPlant Prosthetic Catalog. SwissPlant

Straumann. This is a real breakthrough. Roxolid implant, make the restoration, then go home and sleep well at night.

Product Information. Straumann Variobase Beyond a common Ti-base. Efficiency and flexibility in balance. The NEW. Variobase family members

Standard Plus Implant

Straumann Variobase Family. More than treatment flexibility. Driving efficiency in your lab.

High-end solution STEP-BY-STEP USER GUIDE

Basic information on the surgical and prosthetic procedures. Straumann PURE Ceramic Implant

INSTRUCTIONS FOR THE DENTIST. synocta impression procedure, Screw-retained and Snap-on. Screw-retained (Open tray) Snap-on (Closed tray)

Straumann Variobase Family. More than treatment flexibility. Driving efficiency in your lab.

Smarter Thinking. Simpler Design. Prima Plus. Surgical Manual

IMPRESSION-TAKING, BITE REGISTRATION, AND TEMPORARY RESTORATION ON CAMLOG IMPLANTS. a perfect fit

SwishPlant. SwishPlant System Catalog. 4.8mmD mmD. 4.8mmD mmD. 3.7mmD mmD. 6.5mmD

» Guided Surgery. by MEDENTiKA « MEDENTIGUIDE SURGERY MANUAL QUATTROCONE QUATTROCONE30. IPS Implant systems

Product Catalog 2017/2018. Straumann International Edition

Bridging the Gap Between Original and Multi-Platform Systems.

Straumann ProClean Cassette. Uncompromised hygiene. Ready for action.

Treatment Options for Restoring Edentulous Jaws using One- and Two-Piece Implants from Implant Direct Int l

Height* FC width Prep depth RC width 4.0mm+ 4.3mm N/A 6.3mm

Introduction of Dentium Implant. Help kit

More than an implant. A sense of trust. Straumann Dental Implant System

Product Chart. TOOLS The OSPOL tools fits with all components and both implant diameters. Ø 4,0 mm. Ø 3,35 mm DRILL KIT IMPLANT INSERTER

More than an implant. A sense of trust.

Implant Mountless Package Handling. Instructions for Use

Ø Smaller and Stronger.

The REAL Mini Implant

Legacy Prosthetic Catalog

Straumann Original Clinical Review. General Information

Pre-requisites Step-by-step

Straumann Mini Implant System Basic Information. Technical Information

Fixed Restoration for Atrophic Ridges

Surgical Technique Guide

contents the smarter case approach reasons to choose simplyintegrated 5 system overview 6 ordering 7 mount-free implants 8-9

ATTACHMENT SYSTEM. LOCATOR R-Tx REMOVABLE U.S. RETAIL PRODUCT CATALOG AND PRICE LIST*

INTERNAL HEX Implant System

» Guided Surgery. by MEDENTiKA « MEDENTIGUIDE SURGERY MANUAL MICROCONE. IPS Implant systems

Stock Prosthetic Guide 2014

HEXAGON Implant System

Ø Smaller and Stronger.

Pilot guided surgery

DISTRACTION PRODUCT OVERVIEW. For a wide variety of facial applications

Orthodontic Screw System

LOCATOR F-Tx FIXED ATTACHMENT SYSTEM

Transforming the Implant Industry. Broadest Product Line Highest Quality-Best Value

Cervical Solutions. Optio-C Anterior Cervical Plate. with Allograft/Autograft. Surgical Technique Guide

Description: Prosthetic Components for dental restoration under CE-Series, CL- Series, CN-Series, CH-Series, CF-Series, CR-Series, CS-Series.

Ankylos. Repair Manual

Implant And Abutment Level Impressions

Multi-Unit Abutment System SIC Safe on Four. Optimum use of available bone by angled placement of implants

Product Information for Labs. etkon ident Perfectly versatile. Performance you can rely on.

Astra Tech Implant System. Manual and product catalog OsseoSpeed TX Profile

Osteoconductive S.L.A. Surface. Fantastic surface, Bioseal, and Perfect achievement of CMI f ixation.

NARROW DIAMETER implant

Catalog. etkon ident Compatibles perfected. From a partner you can trust _etkon_iDent_Catalogue_nordic indd :56:11

a perfect fit INSTRUCTION MANUAL CAMLOG TORQUE WRENCH WITH CONTINUOUS TORQUE ADJUSTMENT Handling Sterilization Care

SimpleLine II Surgical / Prosthesis Manual

Astra Tech Implant System. Product catalog. OsseoSpeed TX

The LOCATOR concept. Simplicity and versatility for prosthesis fixation

RDS IMPLANTS PERFECTLY DESIGNED - SIMPLY ASSIGNED

INTERNAL HEX ( ps) PLATFORM SHIFT PRESERVATION OF BONE NEVER LOOKED BETTER

ORTH easy. The Complete System for Cortical Anchorage. OrthoEasy Pins

SURGICAL MANUAL GRAND MORSE

OPTIONAL/ADDITIONAL INSTRUMENTS

ZMR Over-the-Junction Instruments for Revision Hip Arthroplasty. Surgical Technique IMAGE TO COME

Legacy TM. System Catalog. Legacy TM 1 Legacy TM 2 Legacy TM 3 Legacy TM 4

3. Guarantee conditions

Guided surgery manual

3M ESPE MDI. Mini Dental Implants. Quick Order Guide

Transcription:

SURGICAL PROCEDURES FOR ROXOLID IMPLANTS 1

ABOUT THIS BROCHURE The brochure Surgical Procedures for Roxolid Implants provides dental practitioners and related specialists with information about the implant and its surgical procedure. For further information, please refer to the main surgical brochure Basic Information on the Surgical Procedure Straumann Dental Implant System. The brochure is divided into the following main parts: pp Straumann Roxolid Implants pp Indications and contraindications pp Preoperative planning pp Surgical procedures pp Overview of implants For further information about the NNC prosthetic procedure, please refer to the following brochure: Prosthetic Procedures for the Narrow Neck CrossFit Implant.

1. STRAUMANN ROXOLID IMPLANTS 1.1 OVERVIEW Straumann Roxolid Implants offer six implant lines with diverse body and neck designs, ranging from the classic Soft Tissue Level to the Bone Level Implant and some additional hybrid solutions. All implants can be placed with the Straumann Surgical cassette while using very similar surgical procedures. S SP NNC 4SI TE BL S Straumann Standard Implant SP Straumann Standard Plus Implant NNC Straumann Narrow Neck CrossFit Implant 4SI TE BL Straumann 4 mm Short Implant Straumann Tapered Effect Implant Straumann Bone Level Implant Straumann dental implants are available in three endosteal diameters: Ø 3.3 mm, Ø 4.1 mm, and Ø 4.8 mm. A unified color code simplifies the identification of instruments and implants. Color coding yellow Endosteal implant diameter 3.3 mm red Endosteal implant diameter 4.1 mm green Endosteal implant diameter 4.8 mm 1

1.2 SPECIFIC DESIGN FEATURES 1.2.1 NARROW NECK CrossFit The Narrow Neck CrossFit (NNC) Implant is a 3.3 mm diameter implant with a narrow prosthetic platform. The NNC Implant is a Standard Plus (SP) Soft Tissue Level Implant with a machined neck of 1.8 mm in height. The implant body and thread design is the same as the Straumann 3.3 mm Bone Level NC Implant. Soft Tissue Level Standard Plus (SP) CrossFit at soft tissue level CrossFit Bone Level Body and thread design same as Straumann Bone Level NC Implant 1.2.2 4 MM SHORT IMPLANT (4SI) The 4 mm Short Implant is a Standard Plus Soft Tissue Level Implant with a Bone Level thread design. The implant is compatible with the whole soft tissue level prosthetic platform. synocta Soft Tissue Level Standard Plus (SP) synocta at soft tissue level Bone Level Body and thread design same as Straumann Bone Level NC Implant 2

1.2.3 LOXIM THE NEW TRANSFER PIECE The Straumann Roxolid Implants will be delivered with the Loxim, which is not screw-retained, but connected to the implant with a snap-in mounting. After insertion of the implant, the Loxim can be released by hand or with the help of tweezers. Counter-maneuvering with the Straumann Holding Key is no longer needed. Loxim can be used as an alignment pin to indicate the implant position and angulation for a parallel placement of the neighboring implants. 3

2. SURGICAL PROCEDURE 2.1 INDICATIONS AND CONTRAINDICATIONS To obtain more information about indications or contraindications related to each implant, please refer to the corresponding instructions for use. 2.2 IMPLANT-BED PREPARATION The implant diameter, implant type, position and number of implants should be selected individually taking the anatomy and spatial circumstances into account. The specific measurements should be regarded as minimum guidelines and are further specified in the brochure Basic Information on the Surgical Procedure Straumann Dental Implant System. STEPS INSTRUMENTATION 1. Basic implant-bed preparation Ridge preparation Twist drilling Round bur (fall implants) Pilot drill 1 (2.2 mm) Alignment pin Pilot drill 2 (2.8 mm) Depth gauge Basic implant-bed preparation involves ridge preparation and twist drilling. For twist drilling, the endosteal diameter of the implant (3.3/4.1/4.8 mm) not the implant type or the bone class determines which instruments have to be used. 2. Fine implant-bed preparation Profile drilling Tapping SP/4SI profile drill S/SP Tap BL/NNC profile drill TE profile drill 4SI/BL/TE/NNC Tap Fine implant-bed preparation involves profile drilling and tapping. For tapping, the implant type (S/SP/TE/BL) and the bone class determine which instruments have to be used, with exception of the NNC and 4 mm Short Implants that require a BL tap. Please note: Narrow Neck CrossFit and 4 mm Short Implants have a Standard Plus design, but both implant types require a Bone Level tapping. All Straumann dental implants are placed using one instrument kit the Straumann Surgical cassette. The implant-bed preparation covers two main steps: 4

2.3 IMPLANT PLACEMENT Implant placement with handpiece Implant placement with ratchet Step 1 Attach the handpiece adapter Hold the enclosed part of the implant carrier. Attach the handpiece or the ratchet adapter to the Loxim. A click will be heard when the adapter is attached correctly. Step 2 Remove the implant from the carrier Simultaneously, pull down the implant carrier and lift the implant out of the implant carrier (keep your arms steady). Step 3 Place the implant Place the implant with the handpiece or the ratchet into the implant bed. Move the implant into its final position with a maximum of 15 rpm turning it clockwise. Caution! Vertical position corrections using reverse rotations (counterclockwise) may lead to a decrease in primary stability. Step 4 Remove the instruments Loxim can easily be re-inserted to finish an uncompleted implant placement until the implant is fully inserted. If the implant needs to be removed during implantation surgery, Loxim allows for counterclockwise turns. After insertion, the Loxim is detached with the adapter. Remove the ratchet while holding the adapter at the bottom, and then detach the adapter-transfer piece assembly. 5

2.4 ADDITIONAL INFORMATION Release aid for the Loxim Transfer piece For situations in which any removal force is to be avoided, a release aid for the Loxim can be used. Place the release aid onto the implant shoulder and hold it in place while detaching the adapter with the Loxim. Important additional information An insertion torque of 35 Ncm is recommended. If 35 Ncm are achieved before the implant has reached its final position, make sure the implant-bed preparation is correct to avoid bone overcompression. Warning! In case the implant has to be removed after implant placement, the retention of the Loxim in the implant may be reduced. Always secure the implant against aspiration when removing the implant. The Loxim is provided with a pre-determined breaking point to prevent the implant s inner configuration from damage, thus ensuring the integrity of the interface to mount the prosthesis. If the Loxim breaks during implant insertion, one part remains in the adapter and the other part in the implant. Both parts can be removed with tweezers. To extract the implant after the pre-determined breaking point broke, simply take out the broken part of the Loxim from the adapter and re-insert the adapter on the Loxim part remaining in the implant. Counterclockwise turns will remove the implant. The part of the Loxim below the pre-determined breaking point is not secured in the adapter and, additionally, needs to be secured against aspiration when taking out the implant. Caution! The broken part of the Loxim no longer protects against high torque. Therefore, it is not to be used to advance the placement of the implant. 6

OVERVIEW ROXOLID IMPLANTS Standard Implants RN RN RN WN Ø 4.8 mm Ø 4.8 mm Ø 4.8 mm Ø 6.5 mm 2.8 mm Ø 3.3 mm Ø 4.1 mm Ø 4.8 mm Ø 4.8 mm SLActive S Ø 3.3 RN S Ø 4.1 RN S Ø 4.8 RN S Ø 4.8 WN 6 mm 033.530S 033.580S 033.600S 8 mm 033.501S 033.531S 033.581S 033.601S 10 mm 033.502S 033.532S 033.582S 033.602S 12 mm 033.503S 033.533S 033.583S 033.603S 14 mm 033.504S 033.534S 033.584S 16 mm 033.505S 033.535S Standard Plus Implants NNC RN RN RN WN Ø 3.5 mm Ø 4.8 mm Ø 4.8 mm Ø 4.8 mm Ø 6.5 mm 1.8 mm Ø 3.3 mm Ø 3.3 mm Ø 4.1 mm Ø 4.8 mm Ø 4.8 mm SLActive SP Ø 3.3 NNC SP Ø 3.3 RN SP Ø 4.1 RN SP Ø 4.8 RN SP Ø 4.8 WN 6 mm 033.560S 033.590S 033.610S 8 mm 033.416S 033.511S 033.561S 033.591S 033.611S 10 mm 033.417S 033.512S 033.562S 033.592S 033.612S 12 mm 033.418S 033.513S 033.563S 033.593S 033.613S 4 mm Implants RN RN WN Ø 4.8 mm Ø 4.8 mm Ø 6.5 mm 1.8 mm Ø 4.1 mm Ø 4.8 mm Ø 4.8 mm SLActive SP Ø 4.1 RN SP Ø 4.8 RN SP Ø 4.8 WN 4 mm 033.043S 033.044S 033.045S 7

Tapered Effect Implants RN RN WN Ø 4.8 mm Ø 4.8 mm Ø 6.5 mm 1.8 mm Ø 3.3 mm Ø 4.1 mm Ø 4.8 mm SLActive TE Ø 3.3 RN TE Ø 4.1 RN TE Ø 4.8 WN 8 mm 033.521S 033.571S 10 mm 033.522S 033.572S 033.622S 12 mm 033.523S 033.573S 033.623S 14 mm 033.524S 033.574S 033.624S Bone Level Implants NC RC RC Ø 3.3 mm Ø 4.1 mm Ø 4.8 mm Ø 3.3 mm Ø 4.1 mm Ø 4.8 mm SLActive BL Ø 3.3 NC BL Ø 4.1 RC BL Ø 4.8 RC 8 mm 021.2308 021.4308 021.6308 10 mm 021.2310 021.4310 021.6310 12 mm 021.2312 021.4312 021.6312 14 mm 021.2314 021.4314 021.6314 Release aid N for Loxim (for NNC and NC) 026.2558 Release aid R/W for Loxim (for RC, RN and WN) 026.4558 8

www. straumann.com International Headquarters Institut Straumann AG Peter Merian-Weg 12 CH-4002 Basel, Switzerland Phone +41 (0)61 965 11 11 Fax +41 (0)61 965 11 01 Institut Straumann AG, 2013. All rights reserved. Straumann and/or other trademarks and logos from Straumann mentioned herein are the trademarks or registered trademarks of Straumann Holding AG and/or its affiliates. All rights reserved. Straumann products are CE marked 08/13 152.809/en