PEMODELAN BERKAS UNTUK FASILITAS PGNAA PADA REAKTOR KARTINI

Similar documents
Bulaksumur, Yogyakarta 55281, Indonesia. Indonesia.

Feasibility study to develop BNCT facility at the Indonesian research reactor

A Feasibility Study of the SLOWPOKE-2 Reactor as a Neutron Source for Boron Neutron Cancer Treatment

Design of Moderator Neutron for Boron Neutron Capture Therapy in Kartini Nuclear Reactor Using Monte Carlo N Particle 5 Simulation

RPI DOSIMETRY. Therefore the description of the work is grouped in two main areas:

Neutron sources from Nuclear Reactors

Djoko S. Pudjorahardjo, Widarto, Isman Mulyadi T

Investigating a cyclotron HM-30 based neutron source for BNCT of deep-seated tumors by using shifting method

Indonesian Journal of Physics and Nuclear Applications Volume 2, Number 2, June 2017, p ISSN X, FSM UKSW Publication

LA-UR- Title: Author(s): Submitted to: Approved for public release; distribution is unlimited.

Neutron - a tool in the cancer treatment - C. Paunoiu

EPITHERMAL AT REACTOR TRIGA PUSPATI THERMAL

NEUTRON AND GAMMA SPECTRUM ANALYSIS OF KARTINI RESEARCH REACTOR FOR BORON NEUTRON CAPTURE THERAPY (BNCT)

Radiation Dosimetry at the BNL High Flux Beam Reactor and Medical Research Reactor

Numerical optimisation of the fission-converter and the filter/moderator arrangement for the Boron Neutron Capture Therapy (BNCT)

Study of neutron-dna interaction at the IPEN BNCT Research facility ABSTRACT

Design of a BSA for Producing Epithermal Neutron for BNCT

Strategy for Sustainable Utilization of IRT-Sofia Research Reactor

Distribution of Water Phantom BNCT Kartini Research Reactor Based Using PHITS

Development and characteristics of the HANARO ex-core neutron irradiation facility for applications in the boron neutron capture therapy field

Future Utilization of the Research Reactor IRT in Sofia after its Reconstruction

Simulation of the BNCT of Brain Tumors Using MCNP Code: Beam Designing and Dose Evaluation

Progress in Reactor and Accelerator Based BNCT at Kyoto University Research Reactor Institute

Optimization of an accelerator-based epithermal neutron source for neutron capture therapy

THE HIGH-CURRENT DEUTERON ACCELERATOR FOR THE NEUTRON THERAPY. S.V. Akulinichev, A. V. Andreev, V.M. Skorkin

Development of LINAC-Based Neutron Source for Boron Neutron Capture Therapy in University of Tsukuba )

Boron Neutron Capture Therapy (BNCT) - Low-Energy Neutron Spectrometer for Neutron Field Characterization - )

Single Photon Emission Tomography Approach for Online Patient Dose Assessment in Boron Neutron Capture Therapy

Design and Performance Of A Thermal Neutron Beam for Boron Neutron Capture Therapy At The University Of Missouri Research Reactor

Thin Beryllium target for 9 Be(d,n)- driven BNCT

V. 4. Design and Benchmark Experiment for Cyclotron-based Neutron Source for BNCT

Neutrons. ρ σ. where. Neutrons act like photons in the sense that they are attenuated as. Unlike photons, neutrons interact via the strong interaction

Neutron Detection Spring 2002

Neutron Interactions Part 2. Neutron shielding. Neutron shielding. George Starkschall, Ph.D. Department of Radiation Physics

EPITHERMAL NEUTRON BEAM GENERATOR DESIGN FOR BNCT

COMPARING THE RESPONSES OF TLD 100, TLD 600, TLD 700 AND TLD 400 IN MIXED NEUTRON-GAMMA FIELDS

Today, I will present the second of the two lectures on neutron interactions.

Epithermal neutron beams from the 7 Li(p,n) reaction near the threshold for neutron capture therapy

Determination of Iodine in Biological Materials using Instrumental Neutron Activation and Anti-coincidence Gamma-ray Spectrometry

JURNAL TEKNOLOGI REAKTOR NUKLIR TRI DASA MEGA

OPTIMIZATION OF A NEUTRON BEAM SHAPING ASSEMBLY DESIGN FOR BNCT AND ITS DOSIMETRY SIMULATION BASED ON MCNPX

Monte Carlo Modelling: a reliable and efficient tool in radiation dosimetry

Development of a Thermal Neutron Source based on a Medical Electron Linac

Option D: Medicinal Chemistry

Accelerator Based Epithermal Neutron Source by using Thin Layered Solid Lithium Target

Multifunctional Novel Boron-Carbon Fiber Polymer Composites for Mixed Radiation Field Space Applications

Neutron Induced Radiation Damage in BaF 2, LYSO and PWO Scintillation Crystals

PhD értekezés tézisei PHASE I CLINICAL STUDY ON BORON NEUTRON CAPTURE THERAPY. Dr Katalin Hideghéty. A Doktori Iskola vezetıje Prof. Dr.

Real Time Spectrometer for thermal neutrons from Radiotherapic Accelerators

Miroslav Žamboch February 2015, IAEA,Vienna

The Albedo Dosimeter for Personnel Monitoring in Fast-Neutron Radiation Fields

INTEGRATION OF MEDIAN FILTER AND ORIENTATION FIELD ESTIMATION FOR FINGERPRINT IDENTIFICATION SYSTEM

Feasibility of BNCT and Neutron Imaging with 1Hz, 5kJ Plasma Focus Neutron Source at the ICTP-MLAB Laboratory

Title. Author(s)Ishikawa, Masayori; Tanaka, Kenichi; Endo, Satrou; H. CitationJournal of Radiation Research, 56(2): Issue Date

IAEA Activities in support of Neutron Imaging

Production and dosimetry of simultaneous therapeutic photons and electrons beam by linear accelerator: a monte carlo study

Lithium Borohydride for Hydrogen Propellant Storage

NaI Detector and Photo-multiplier Tubes

Preliminary study of MAGAT polymer gel dosimetry for boron-neutron capture therapy

Challenges of Hungarian nuclear NDT regarding existing plants and new-builds

Custom-Made Products / Scientific Research Instruments

Radiotherapy. Marta Anguiano Millán. Departamento de Física Atómica, Molecular y Nuclear Facultad de Ciencias. Universidad de Granada

Safety. Economy. Design Criteria for the HTR Core. Jan Leen Kloosterman, Physics of Nuclear Reactors, TU-Delft

AUTHOR QUERIES - TO BE ANSWERED BY THE CORRESPONDING AUTHOR

[Setawati et. al., Vol.4 (Iss10): October, 2017] ISSN: DOI: /zenodo

MODELLING A GAMMA IRRADIATION PROCESS USING THE MONTE CARLO METHOD

COMPARISON STUDY OF RELAY SELECTION SCHEMES IN LONG TERM EVOLUTION (LTE) NETWORK SELINA MATTHEWS UNIVERSITI TEKNOLOGI MALAYSIA

THERMOLUMINESCENT (TL) DOSIMETRY OF SLOW-NEUTRON FIELDS AT RADIOTHERAPY DOSE LEVEL

7. Radioisotopes in Medicine

Development of Ultrasonic Sensor for Visualisation under Heavy Liquid Metal

Developments in Ultrasonic Inspection II

Cancer Therapy: A new horizon

We are providing Level I, II Training and Certification as per Recommended practice SNT TC 1A 2006 in the following NDT Methods.

On Optimizing the 7Li(p,n) Proton Beam Energy and Moderator Materid for BNCT

Mathematical Optimization Methodology for Neutron Filters

Introduction to sodium technology Neutronic characteristics of sodium and complexities

CHARACTERIZATION OF THE ELECTRON BEAM RADIATION FIELD BY CHEMICAL DOSIMETRY

SHIELDING TECHNIQUES FOR CURRENT RADIATION THERAPY MODALITIES

IAEA-TECDOC Current status of neutron capture therapy

On the optimal energy of epithermal neutron beams for BNCT

Neutron Measurements for Intensity Modulated Radiation Therapy

ABSTRACT. Professor Mohamad Al-Sheikhly, Department of Materials Science and Engineering

RDHA710FR10A1NK. Neutron and Total Ionizing Dose Test Report. October 2009

International Association of Scientific Innovation and Research (IASIR) (An Association Unifying the Sciences, Engineering, and Applied Research)

22.55 Principles of Radiation Interactions Name: Spring 2004 Professor Coderre Exam 2 April 30, 2004

Present status and future of Proton beam therapy

Radiation Protection in BNCT Patients

Nuclear Radiation Today

Description of the consecutive stages (which took place from December 2002 to July 2003)

Shielding Design Basis and its Calculation of High Energy Medical Linac Installed in Bangladesh Atomic Energy Commission, Bangladesh

G.E. M C M I C M L, T.J. YULE Technology Development Division, Argonne National Laboratoy, Argonne, IL, 60439

INVESTIGATION OF ROLLOVER PERFORMANCE FOR MALAYSIA BUS SUPERSTRUCTURE MOHAMMAD AMIRUL AFFIZ BIN AFRIPIN UNIVERSITI TEKNOLOGI MALAYSIA

Proton Treatment. Keith Brown, Ph.D., CHP. Associate Director, Radiation Safety University of Pennsylvania

Comparison between proton boron fusion therapy (PBFT) and boron neutron capture therapy (BNCT): a Monte Carlo study

Sources of ionizing radiation Atomic structure and radioactivity Radiation interaction with matter Radiation units and dose Biological effects

University of Wollongong. Research Online

nuclear science and technology

Experiences in Neutron Dosimetry

AN ABSTRACT OF THE THESIS OF. Leanna R. Eller for the degree of Master of Science in Radiation Health Physics

Current Activities at the MIT Research Reactor. Lin Wen Hu John A. Bernard Otto K. Harling Gordon E. Kohse Michael Ames ]Than Olmez

Transcription:

9 0 Beam Modeling For PGNAA Experimental Facility at Kartini Reactor BEAM MODELING FOR PGNAA EXPERIMENTAL FACILITY AT KARTINI REACTOR PEMODELAN BERKAS UNTUK FASILITAS PGNAA PADA REAKTOR KARTINI Tegas Sutondo Center for Accellerator Science and Technology (CAST), BATAN Jl. Babarsari, P.O. Box 6101 ykbb, Yogyakarta 55281 e-mail: tegas@batan.go.id; tegas_s@yahoo.com Received 25 May 2016, received in revised form 17 July 2015, accepted 30 July 2015 ABSTRACT BEAM MODELING FOR PGNAA EXPERIMENTAL FACILITY AT KARTINI REACTOR. A feasibility study on possible use of Kartini reactor s beam port for Prompt Gamma Neutron Activation Analysis (PGNAA) experimental facility is going on. This work is part of the revitalization program activities of Kartini research reactor, including utilization of the available irradiation facilities. This paper presents results of beam modeling at the tangential beam port to get neutron beam meeting the specified criteria. The study was conducted by means of simulations using MCNPX code. The result concludes that there are several possible variations of collimator models that can provide neutron beam meeting the specified criteria and that tangential beam port is considered to be feasible enough for the purpose of PGNAA experimental facility Keywords: beam, modeling, PGNAA, facility, Kartini reactor. ABSTRAK PEMODELAN BERKAS UNTUK FASILITAS PGNAA PADA REAKTOR KARTINI. Pada saat ini sedang dilakukan studi kelayakan terkait kemungkinan penggunaan beam port dari reaktor Kartini untuk sarana eksperimen Prompt Gamma Neutron Activation Analysis (PGNAA). Kegiatan ini bagian dari program revitalisasi dari reaktor Kartini, termasuk pemanfaatan fasilitas irradiasi yang ada. Makalah ini menyajikan hasil dari pemodelan berkas pada beam port singgung untuk mendapatkan berkas neutron sesuai dengan persyaratan yang ditetapkan. Studi ini dilakukan berdasarkan dengan cara simulasi menggunakan program PCNPX. Dari hasil simulasi dapat disimpulkan bahwa ada beberapa variasi model kolimator yang dapat menghasilan berkas neutron sesuai kriteria yang ditetapkan, dan beam port singgung cukup layak untuk digunakan sebagai fasilitas eksperimen PGNAA. Kata kunci: pemodelan, berkas, fasilitas. PGNAA, reaktor Kartini. INTRODUCTION K artini reactor is a pool type TRIGA mark II reactor, operated with nominal power of 100 kw, and equipped with several irradiation facilities, including 4 beam ports that can be used for many different applications, as shown in Figure 1. 6 11 8 5 7 10 3 1 2 4 9 8 12 1 = Reactor core 2 = Graphite reflector 3 = Water coolant 4 =Thermal column 5 = Thermalizing column 6 =Spent fuel storage 7 = Piercing beam port 8 = Radial beam port 9 = Tangential beam port 10 = Biological shielding 11 = Subcritical assembly Figure 1. Horizontal cut view of Kartini Reactor. 107

Neutron Flux [ n / ( cm 2 s ) ] Radiation Doses (rem / h) J. Iptek Nuklir Ganendra Ganendra Journal of Nuclear Science and Technology Vol. 18 No. 2 Juli 2015: 107-113 Among the irradiation facilities available, Lazy Susan is being the most frequently used for elemental analysis, based on the Neutron Activation Analysis (NAA) techniques, which is known as DGNAA (Delayed Gamma Neutron Activation Analysis). In conjunction with the revitalization program of Kartini reactor, there is interest to build a PGNAA experimental facility by utilizing one of the beam ports which are still not utilized optimally, i.e. radial piercing, radial and tangential beam ports. PGNAA is another variant of NAA techniques, working based on the gamma rays emitted promptly following the decay of the compound nucleus (CN) formed in the excited state. The intensity of the gamma-rays emitted is directly proportional to isotopic (elemental) concentrations. This technique has enabled the in situ and on-line application such as those used in coal mining; cement industries, etc. (1-4). PGNAA technique, basically can work with the whole range of neutron energy spectrum, depending on the neutronic properties of the sample to be analyzed. However for most research application it is preferred to use neutrons of lower energy range, since activation reactions occur mostly with neutrons of low energies. An exception is for nuclides having very low thermal neutron capture reaction such as carbon, it is preferred to use fast neutron, throughout the neutron inelastic scattering reaction (2). For PGNAA working with thermal neutron, the contribution of epithermal activation reactions, may affect the accuracy of the result, and therefore it should be minimized as much as possible to a reasonable level. This commonly indicated with the amount of thermal over epithermal neutron fluxes ratio (f), implying that the higher the value of f will be the better the quality of the neutron beam accordingly. A minimum f value of 100 was considered to be reasonable, with minimum thermal neutron flux = 1.0 10 6 n cm -2 s -1 (5). In this respect, attempt will be made to get neutron beam meeting the above criteria. A preliminary study has been carried out by characterizing the three kinds of beam port to select the most suitable one which is going to be used; i.e. the radial piercing and tangential beam port (6) and then also to include the radial beam port which was previously used for neutron radiography experimental facility. The study was performed by means of simulation using MCNPX code. Figure 2 summaries results of simulation of the neutron beam at the beam ports exit and Figure 3 is the corresponding radiation dose of both neutron and photon radiation. 1.E+09 1.E+08 Thermal neutron Epithermal neutron Fast neutron 1.E+04 Neutrons Photons (gamma rays) 1.E+03 1.E+07 1.1640E+07 5.9806E+06 2.3813E+06 1.E+02 1.E+06 1.E+05 Radial piercing Radial Tangential 1.E+01 Radial piercing Radial Tangential Figure 2. Beam characteristics at the beam port exit. Figure 3. The radiation dose at the beam port exit The result shows that the radial piercing beam port provides the highest value of neutron fluxes. The photon radiation dose is also very high which is comparable with that of radial beam port. The high intensity of both fast neutrons and photons would need more works to do for both moderating the fast neutrons and suppressing the gamma rays as well. Radial beam port seen to give highest thermal neutron compared with the others, however the gamma rays radiation dose is of the same order with that of radial piercing beam port. Finally the tangential beam port provides much lower fast neutron and gamma rays radiation dose. This can help simplify the problems of both moderating the fast neutron and suppressing the gamma rays. Based on the above results, it was then decided to use tangential beam port as the object of collimator modeling in this work. Figure 4 depicts the tangential beam port, consisting two sections i.e. inner section made of aluminum and outer section made of steel both with thickness of 0.95 cm. 108

Beam Modeling For PGNAA Experimental Facility at Kartini Reactor 114.7 cm 155.0 cm Al tube Steel tube 15.24 cm 20.32 cm Outer side of graphite reflector 175 cm Figure 4. Inner and outer sections of tangential beam port. METHODOLOGY There are many different models of collimator having been developed, for several different applications (7-11). In this study, a basic geometrical model of collimator as represented in Figure 5 was used. The collimator consists of three main sections i.e. inner, middle and outer sections each with the length of L-1, L-2, and L-3 respectively. L-1 L-2 L-3 Filter Shutter box Inner section Middle section Outer section Figure 5. Basic shape of the collimator model. The goal of this work is to suppress the gamma rays component to a reasonable level that can help simplify the problem of shielding and to get neutron beam meeting the defined criteria. This will be performed by means of selecting the suitable materials and adjusting the dimensions of each collimator section. For this purpose, it will be prioritized to use materials available in local market and relatively inexpensive. Lead (Pb), with density of 11.34 g/cm 3 is good for suppressing gamma rays, and it has also low neutron capture cross section which is relatively transparent against neutron passage (12, 13). In this respect, it will be used for the main component of collimator wall. Another material having similar properties with lead is bismuth (Bi) with density of 9.780 g/cm 3. It has low neutron capture cross section and high neutron elastic cross section that can improve the neutron transmission. In this respect, it will be included as part of evaluation for material of filter, inner and or outer sections wall. Polyethylene of high density (HDPE) with density of 0.95 g/cm 3 has low neutron capture cross section and high elastic scattering cross section which could improve the moderation of fast neutrons. It was also included in the evaluation for material of inner and outer section wall to help increase the thermal neutron production. All of the above materials are easily obtained in local market and relatively inexpensive. Figure 6, 7, and 8 shows the MCNPX plot of neutron capture cross sections of lead, bismuth and HDPE respectively and Fig. 9, 10, 11 are the corresponding elastic scattering cross sections. The MCNP geometrical representation was prepared and a Visual Editor - VISED Version X_22S (15) was used for visual reviewing of the geometrical model. Simulations were performed for several different models which include the variation of materials for both the filter and collimator wall of inner and outer sections, and the corresponding dimensions. In this study, the criticality source (KCODE) option was used to calculate neutrons and photons fluxes, normalized to reactor power of 100 kw. 109

J. Iptek Nuklir Ganendra Ganendra Journal of Nuclear Science and Technology Vol. 18 No. 2 Juli 2015: 107-113 82000.50c 83209.60c Figure 6. Neutron capture cross section of lead. Figure 7. Neutron capture cross section of bismuth. 1001.50c 6012.50c 82000.50c Figure 8. Neutron capture cross section of HDPE. Figure 9. Neutron elastic cross section of lead. 83209.60c 1001.50c 6012.50c Figure 10. Neutron Elastic cross section of bismuth. Figure 11. Neutron elastic cross section of HDPE. 110

Beam Modeling For PGNAA Experimental Facility at Kartini Reactor RESULTS AND DISCUSSIONS Several cases of simulation had been exercised based on the basic collimator model as represented by Figure 5. Figure 12 shows a piece of MCNP geometrical representation of a collimator model placed at the outer section of the tangential beam port. Filter Collimator Shutter box Figure 12. Piece of the MCNP representation of collimator model. Table 1 presents results of several cases of simulation using filter material of either lead or bismuth, with the same thickness of 5.0 cm, which can provide neutron beam at the exit, meeting the minimum defined criteria. In case-1, the filter and the wall of collimator sections all use material of lead. Based on the prescribed collimator dimensions the photons and the epithermal and fast neutrons can be removed from the beam at the exit. The thermal flux obtained is still higher than the defined minimum value of 1.0 10 6 n cm -2 s -1 (5). In case-2, the filter material was replaced by bismuth (Bi) and the length of inner section (L-1) was extended by 10 cm, (which result in the reduction of L-2 by 10 cm). This way could result in the increase of thermal neutron flux, but then with the presence of fast neutrons component. The presence of fast neutron theoretically would not give a significant contribution to the accuracy of the PGNAA since the activation cross section is much lower than that of thermal neutron. However, if most of fast neutron energies close to the upper limit of epithermal energy, it could affect the accuracy of the result. In case-3, simulation was made by replacing the material of inner section wall with bismuth and outer section wall with HDPE, whilst keeping the dimensions unchanged. This way could remove the fast neutron component, but with a bit appearance of gamma rays which can then be removed by slightly reducing the outer radius of aperture as seen in case-4. The thermal neutron beam obtained represents the average value of several repeated simulation results, with relative differences of around 13%. However more repetitions of the simulations might still be needed to get the best representing result. This value seen to be much higher compared with that obtained in case-1 which used lead for both filter and all sections of the collimator wall. Table 1. Result of simulations. Cases of Simulation Case - 1 Case - 2 Case - 3 Case - 4 Filter Thickness (cm) 5.0 5.0 5.0 5.0 Material Filter Lead Bismuth Bismuth Bismuth Inner section Lead Lead Bismuth Bismuth Middle section Lead Lead Lead Lead Outer section Lead Lead HDPE HDPE 111

J. Iptek Nuklir Ganendra Ganendra Journal of Nuclear Science and Technology Vol. 18 No. 2 Juli 2015: 107-113 Cases of Simulation Case - 1 Case - 2 Case - 3 Case - 4 Length (L-1, L-2, L-3) / radius of base / radius of top (cm) Inner section 20 / 7.5 / 7.5 30 / 7.5 / 7.5 30 / 7.5 / 7.5 30 / 7.5 / 7.5 Middle section 130 / 7.5 / 3.0 120 / 7.5 / 3.0 120 / 7.5 / 3.0 120 / 7.5 / 2.5 Outer section 20 / 3.0 / 3.0 20 / 3.0 / 3.0 20 / 3.0 / 3.0 20 / 2.5 / 2.5 Neutron flux at the exit ( n cm -2 s -1 ) Total photon flux at beam exit [ cm -2 s -1 ] Thermal 6.54690 10 6 1.60123 10 7 1.70924 10 7 1.4269 10 7 Epithermal - - - - Fast - 3.49839 10 6 - - - - 4.01497 10 6 - CONCLUSION A series of simulation cases of beam modeling have been carried out as part of feasibility study on using Kartini reactor s beam port for PGNAA experimental facility. Tangential beam port has been selected for the purpose of this study. The study was conducted by means of simulation using MCNPX code. Results of simulation indicate that there are several possible variations of collimator models that can provide neutron beam meeting the specified criteria. Based on the simulation results, it is concluded that the tangential beam port is feasible enough for the proposed of PGNAA application with the neutron beam at the beam port exit meets the specified criteria. ACKNOWLEDGMENT The author would like to thank to Director of CAST-BATAN Yogyakarta, Prof. Sudjatmoko, Prof. Syarip, the manager and the project coordinator for their great supports. REFERENCES 1. DARIUSH REZAI, MOHAMMAD MOHAMMADI, Prompt Gamma Neutron Activation Analysis of Carbon Bulk Samples with an Am-Be Neutron Source, JTPC, Vol. 1 (2012) 11-13 2. TAREK Q. QASIM, TAWFEQ AL-ETAIWI, MOHAMMED AL-KHASHEB, Analysis and Developments of PGNAA Installation at Al-Rashadiya Lafarge Cement Plant in Jordan, Proceedings of the 2011 International Conference on Industrial Engineering and Operations Management, Kuala Lumpur, Malaysia, January 22 24, (2011) 1219-1224 3. DARRELL LEETHAM, PGNAA Improves Process and Quality Control in Cement Production, Accelerating Science, (2014) 4. AKHTAR ABBAS NAQVI, et al, Prompt Gamma-Ray Analysis of Steel Slag in Concrete, Journal of Nuclear Science and Technology, 46:7, Published online: 19 Mar (2012) 737-743 5. ALEXANDRE SOARES LEAL*, DANIEL CAMPOLINA, ZSOLTREVAY, Feasibility Of The Prompt-Gamma Neutron Activation Analysis Facility At Trigaipr-R1 Reactor In Brazil, International conference on research reactor safe management and effective utilization, Proceeding IAEA-CN-188-A19, Rabat Morocco 14-18 November (2011) 1-8 6. TEGAS SUTONDO and SYARIP, Karakteristik Berkas Pada Beam Port Tembus dan Singgung Reaktor Kartini, Ganendra Journal of Nuclear Science and Technology, Vol. 17 No. 2 (2014) 83-90 7. M.R. A ABDI, K.H. REZAEE, P. SHAYAN AND A. FARZANEH, Collimator Design for Neutron Radiography Systems Using a Reactor Flux, Middle-East Journal of Scientific Research 11 (5): (2012) 648-651 112

Beam Modeling For PGNAA Experimental Facility at Kartini Reactor 8. YANG XIAO-PENG, et al. Neutron collimator design of neutron radiography based on the BNCT facility, Chinese Physics C, Vol. 33, No 1, (2013) 010201, 1-5 9. J. G. FANTIDIS, et al, A transportable neutron radiography system, J Radioanal Nucl Chem 284 (2010): 479 484 10. FATEMEH SADAT RASOULI, SEYED FARHAD MASOUDI, Simulation of the BNCT of Brain Tumors Using MCNP Code: Beam Designing and Dose Evaluation, Iranian Journal of Medical Physics Vol. 9, No. 3 (2012) 183-192 11. VICTOR KREFT, Studies Towards Boron Neutron Capture Synovectomy At Mcmaster University, A Thesis Submitted to the School of Graduate Studies in Partial Fulfillment of the Requirements for the Degree Doctor of Philosophy, McMaster University, Hamilton, Ontario (2014). https://macsphere.mcmaster.ca/handle/11375/ 16157, down loaded on February 6, (2015) 12. N. SHMELEV, G. G. KULIKOV, V. A. APSE, E. G. KULIKOV, AND V. V. ARTISYUK, Radiogenic Lead with Dominant Content of 208Pb: New Coolant and Neutron Moderator for Innovative Nuclear Facilities, Hindawi Publishing Corporation, Science and Technology of Nuclear Installations Volume (2011) 1-12 13. Liquid Metal Coolants For Fast Reactors Cooled By Sodium, Lead, And Lead-Bismuth Eutectic, IAEA Nuclear Energy Series No. Np-T-1.6. 14. A.L. SCHWARZ, R.A. SCHWARZ, AND L.L. CARTER, MCNP/MCNPX Visual Editor (VISED) Computer Code Manual, RSICC id: C00746MNYCP00, February, (2008) 113