EverFlow Dolphin Protect Higher performance, better protection

Similar documents
High Flow Family. Short Term Dialysis Catheters. Dialysis

A CATHETER FAMILY FOR ALL YOUR PATIENT NEEDS

The next step in dialysis catheter technology

Protecting Patients. Preserving Access.

DISCOVER NEW HORIZONS IN FLUID DRAINAGE. Bringing Safety and Convenience to Fluid Drainage Management

Protecting Patients. Preserving Access.

HLS Cannulae Solutions from tip to tip.

HLS Cannulae Solutions from tip to tip.

arrow nextstep antegrade & Arrow Edge The next step in dialysis catheter technology

Acute Therapy Systems. provencare Catheter Sets

Designed to Reduce the Risk of Occlusion (1)

Exceptional Performance and Ease of Placement

Lifecath Twin & Dualyse/Trilyse Permanent and Temporary Renal Catheters

Galt Medical Corp. A leader in vascular and interventional medical devices. part of the GaltNeedleTech TM Family

i INTERACTIVE CATALOG FIND YOUR IDEAL CANNULAE

Disclosure. Tunneled Catheters: How to Get Unstuck. ASDIN 10th Annual Scientific Meeting Final. Thomas Vesely, M.D.

PORTS SETTING THE STANDARD WITH A COMPREHENSIVE FAMILY OF PORTS

Sichol sooksee,rn. Hemodialysis Unit Rajavej Chiang Mai Hospital

BioCath for your temporary vascular access

Arrow Cannon II Plus Retrograde-tunneled, Tip-first Chronic Hemodialysis Catheter

HLS CANNULAE SOLUTIONS FROM TIP TO TIP

Arrow-Clark VectorFlow Hemodialysis Catheter Because in Chronic Hemodialysis Catheters, the Tip Matters

ASEPT. Pleural Drainage System INSTRUCTIONS FOR USE REF LOT STERILE EO. Manufactured for: 824 Twelfth Avenue Bethlehem, PA

Stuck dialysis catheters. ANZSIN 2013 Michael Lam & Kendal Redmond

Award Matrix HPVC Intravenous Access Devices and Administration Consumables (Effective 1st March 2017)

ASEPT. Pleural Drainage System INSTRUCTIONS FOR USE. Rx only REF LOT. STERILE EO Sterilized using ethylene oxide

Part. 2. Urodynamics. Urodynamics. 1 Urethro-cystomanometry Cystomanometry Urethral pressure Abdominal pressure 87

Document No. BMB/IFU/40 Rev No. & Date 00 & 15/11/2017 Issue No & Date 01 & 15/11/2017

Procedures/Risks:central venous catheter

Petite Wound Drainage System. 13mm CWV Drainage System. CWSump. CWV with Trocar

Vascu-PICC WITH CUFF PERIPHERALLY INSERTED CENTRAL VEIN ACCESS CATHETER INSTRUCTIONS FOR USE

2018 CANNULAE CATALOGUE

Split-Stream LONG-TERM HEMODIALYSIS INSTRUCTIONS FOR USE

Anaesthesiology

Aspira* Peritoneal Drainage Catheter

KRUUSE Urinary Catheters

ASEPT Pleural Drainage System

MICS & FEMORAL CANNULAE

Catheters and Wires. Dr. Vaibhav Jain MD,DNB,MNAMS Senior Consultant, IR Medanta, the Medicity, Gurgaon

Making possible personal.

Port Design. Page 1. Port Placement, Removal, and Management. Selecting a Vascular Access Device. Thomas M. Vesely, MD

INNOVATIVE PRODUCTS G, J AND GJ-TUBES WITH ENFit TM CONNECTION

Ureteral Stent. Pusher. Guide Wire

Adult Cannulae. product catalog

Ultrasound User Demonstration

LONG-TERM HEMODIALYSIS CATHETER INSTRUCTIONS FOR USE

2018 HEMODIALYSIS CATHETERS CODING AND REIMBURSEMENT GUIDE

LINEAR. 7.5Fr. IAB Catheter. This document is intended to provide information to an international audience outside of the US.

Pediatric Cannulae. product catalog

PRODUCTS FOR THE DIFFICULT AIRWAY. Courtesy of Cook Critical Care

MANITOBA RENAL PROGRAM

DePuy International Ltd St Anthony s Road Leeds LS11 8DT England Tel: +44 (0) Fax: +44 (0)

Innovation in Technology II: Changed and Improved Design. PD Catheters- designs. Bharat Sachdeva MD LSU Shreveport

DIGESTIVE HEALTH ENTERAL FEEDING PRODUCTS

A Primer on Central Venous Access: Peripherally-Inserted Central Catheters, Tunneled Catheters, and Subcutaneous Ports

Talent Abdominal Stent Graft

Advancing Lives and the Delivery of Health Care. The High-Flow Port Designed for Apheresis

EPIDURAL ANAESTHESIA SET - LARGE, advanced

E S C C R I A L T E A R. One great catheter + maximum barrier insertion. c k. p a. h e. a t. a l. r i t e. A r

I SEE THE BROADEST RANGE OF PRODUCTS THRU my smallest possible incision.*

Central Venous Catheter Insertion: Assisting

LINEAR 7.5Fr. IAB Catheter

NexSite HD, Hemodialysis Symmetric Tip Catheter for long term use. Directions for Use. Contents

Home Health Foundation, Inc. To create more permanent IV access for patients undergoing long term IV therapy.

IV therapy. By: Susan Mberenga, RN, MSN. Copyright 2016, 2013, 2010, 2006, 2002 by Saunders, an imprint of Elsevier Inc.

FIND YOUR IDEAL CANNULAE CATALOG. Designed for your smallest patients

Peritoneal Dialysis Catheter Placement. Peritoneal Dialysis Catheter Placement. Peritoneal Dialysis Catheter Placement

ENGLISH SHORT TERM HAEMODIALYSIS CATHETER

Ureteral Stent. Pusher. Guide Wire. Clamp

St George Hospital Renal Department Internal Policy

Implantable Dialysis Device for Treatment of Renal Failure

Mary Lou Garey MSN EMT-P MedFlight of Ohio

Denver ascites shunts. For patients with refractory ascites

Catheter Tip Design. Disclosure. In Vitro Performance of Long-Term Hemodialysis Catheters. ASDIN 10th Annual Scientific Meeting Final

-vita THORACIC 3G. Stent Graft System SOLUTIONS FOR VASCULAR DISEASE

CONVENTIONAL ADULT CANNULAE

CONVENTIONAL ADULT CANNULAE

The I.V. Catheter Family

Part 1: General requirements

BMI Medical. Ventricular Catheter T

Patient guide: pfm Nit-Occlud PDA coil occlusion system. Catheter occlusion of. Patent Ductus Arteriosus. with the

Emergency/ Rescue SUPERCATH 5 & AZ SAFETY IV CATHETERS

STANDARD CONNECTORS. ENFIT CONNECTORS. EITHER WAY, WE KEEP YOU CONNECTED.

Cardioplegia Circuit Products { CARDIOPLEGIA ADAPTERS}

Assisted Reproduction

Make the right vascular access choice, with Cook s comprehensive line of PICCs.

BIP Central Venous Catheter

Unit 11. Objectives. Indications for IV Therapy. Intravenous Access Devices & Common IV Fluids. 3 categories. Maintenance Replacement Restoration

Peritoneal Dialysis. Life Improved

MAXIMIZE RADIAL SOLUTIONS TO PERIPHERAL CHALLENGES

New Dimensions in Medical Technology

Optimize your hemodialysis procedural bundle.

Soft tissue biopsy needles

Safe-T-Centesis catheter drainage system. Innovations in patient safety, clinician safety and procedural efficacy.

1 Description. 2 Indications. 3 Warnings ASPIRATION CATHETER

HMP 2002 PRODUCT CATALOG THE VASCULAR PRODUCTS COMPANY.

Per-Q-Cath* PICC Catheters with Excalibur Introducer* System

Soft tissue biopsy needles

NYU School of Medicine Department of Radiology Rotation-Specific House Staff Evaluation

Transcription:

EverFlow Dolphin Protect Higher performance, better protection Now available with Glid In bevel for an even smoother insertion EverFlow Dolphin Protect long-term hemodialysis catheter

EverFlow Dolphin Protect catheters now come with Glid In bevel embedding the cuff to facilitate an even smoother insertion in either direction.

Multifunctional surface for perfect protection The EverFlow Dolphin Protect catheter has been prepared using a reactive copolymer coating technology with a microdomain surface structure that mimics the natural surface of cells or proteins. Hydrophilic and hydrophobic domains in nanometer range at the catheter surface fail to interact with domains of cell membranes or proteins.1 This unique surface coating reduces the potential for coagulation activation, helps prevent the catheter s biodegradation2 and provides higher blood flow rates at the same time. Integrating the Bismuth additive into the catheter s surface coating makes it the first coating system on the market to provide antibacterial protection without the release of active agents.3 Optimized flow for maximum performance With its optimized lumen design, the EverFlow Dolphin Protect catheter allows best possible flow rates. The sidehole free tip design minimizes the clotting risk and prevents catheter suction to the vessel wall. Your benefits: prolonged catheter ization time and better, safer performance throughout the entire treatment. Better treatment quality for your patients EverFlow Dolphin Protect catheters offer improved conditions for long-term patient care, the result of a carefully selected combination of design and materials. Placement flexibility and safety are increased thanks to the softness of the material which enables tortuous vessel routes to the right atrium, and the smoothness of the material which minimizes vessel trauma and optimizes blood flow. The correct catheter position can be easily checked after implantation thanks to the catheter s MRI and X-ray safety. To securely keep the correct position until final ingrowth of the cuff, EverFlow Dolphin Protect catheters offer a second suture wing that can be positioned flexibly. 3

Benefit from fewer catheter changes and thus reduced costs The gold standard of surface coating for perfect protection The clinical proof:* 4, Significantly prolonged catheter survival Significantly more treatments per catheter Higher efficiency with lower dysfunction rate Reduced clotting risk Reduced bacterial colonization * Clinical studies performed with Dolphin Protect surface modification.

New ways of reducing infection risk The unique Dolphin Protect technology already integrates the antibacterial Bismuth additive into the catheter s surface coating. This helps decrease the risk of catheter-related infection one of the major complications associated with the use of indwelling catheters in hemodialysis patients. Dolphin Protect is, in fact, the first antibacterial coating system on the market to work without the release of pharmaceuticals, i.e. antibiotics, or other active components like silver. Microdomain surface reduces interaction between cells, plasma proteins and the catheter surface The presence of alternating hydrophilic and hydrophobic segments in a nanoscale range helps lower the potential for coagulation activation. This leads to improved biocompatibility. Smooth surface reduces platelet activation and bacterial adhesion Scanning electron microscopy of coated and uncoated surfaces illustrates the differences after 24-h incubation with S. epidermidis: reduced bacterial adhesion and proliferation through Dolphin Protect coating. Antibacterial Bismuth additive helps decrease the risk of catheter-related infection Confocal laser scanning microscopy of coated and uncoated surfaces shows the differences after 96-h incubation with S. epidermidis: no biofilm with Dolphin Protect coating. Coated Uncoated Coated Uncoated

Benefit from higher treatment quality Advanced catheter design for more favorable flow rates Blood flow rates 100 0 Method: in vitro testing Pump system: double roll hose pump 0-0 -100-10 -200 Fluid: bovine blood Arterial Pressure (mmhg) 10 Venous 200 Protein: 60 +/ g/l Hematocrit value: 32 +/ 2% Temperature: 37 +/ 2 C 0 0 100 10 200 20 300 Blood flow rate EverFlow Dolphin Protect (MC-GDPK-121) 30 400 40 00

Maximize the efficiency of your dialysis therapy HighFlow-tip design without sideholes Clinical observations indicate that conventional catheters with sideholes have considerably lower blood flow rates than those without sideholes.6 In line with this statement, the specially engineered EverFlow Dolphin Protect catheter has no sideholes a significant advantage that helps prevent clotting, one of the most frequent complications in catheter application. Kidney-shaped lumen design If arterial and venous lumens are the same size, as they are in conventional double D lumen catheters, pressure placed on the catheter may distort a straight septum which can cause pressure to spike. The EverFlow Dolphin Protect catheter is designed with an arterial lumen which is 20% larger than the venous lumen. With its improved lumen design for a better surface-to-volume ratio, the EverFlow Dolphin Protect catheter allows for more desirable blood flow rates at lower arterial pressure. You benefit from prolonged catheterization time and better, safer performance throughout the entire treatment. With sideholes Sidehole-free HighFlow tip reduces clotting risk Double-D HighFlow Kidney-shaped lumen design allows for better flow rates Flow rate comparison Venous 200 10 100 0 0-0 -100-10 -200 Arterial Pressure (mmhg) Greater flow of kidney-shaped over double D lumen catheter 0 0 100 10 200 20 300 30 400 40 00 Blood flow rate (ml/min) Gambro HighFlow catheter with kidney-shaped lumen Conventional double D lumen catheter 7

EverFlow Dolphin Protect double lumen catheter kits Product name Product code OD (F) Implant length (mm) Body length (mm) Material Units per box MC-GDPK-117 11337 1 170 240 Soft PUR + Dolphin Protect* MC-GDPK-121 113376 1 210 280 Soft PUR + Dolphin Protect* MC-GDPK-12 11338 1 20 320 Soft PUR + Dolphin Protect* MC-GDPK-129 113384 1 290 360 Soft PUR + Dolphin Protect* Kit contains: catheter, introducer needle GPN-177, calibrated guidewire with J tip GGW-3870J, 2 x luer lock injection cap GIC-100, suture ring, tunneling trocar, vessel dilator 13F x 10 mm, split sheath dilator system 16F x 10 mm, wound dressing, safety scalpel Not available as GamCath accessory. * PUR-PDMS-PCL/Bi Copolymerfilm References 1. Deppisch R, Goehl H, Smeby L, Microdomain structure of polymeric surfaces-potential of improving blood treatment procedures, Nephrol Dial Transplant. 1998; 13: 134-139 2. Verbeke F, Haug U, Dhondt A, Beck W, Schnell A, Dietrich R, Deppisch R, Vanholder R. The role of polymer surface degradation and barium sulphate release in the pathogenesis of catheter-related infection. Nephrol Dial Transplant. 2010; 2: 1207-1213 3. Dietrich R, Haug U, Schnell A, Mack A, Ruhl U, Stemmer S, Deppisch R, Development of an anti-thrombogenic and anti-biofilm surface for application in vascular access technology, J Blood Purification 200; 23:39-41 [13A] 4. Meier P, Prolonged catheter survival in patients with acute kidney insufficiency on Continuous Renal Replacement Therapy using a less thromobogenic micropatterned polymer modification, Nephrol Dial Transplant. 2011; 26: 628-63. Schindler R, Heemann U, Haug U, Stoelck B, Karatas A, Pohle C, Deppisch R, Beck W, Hollenbeck M, Bismuth coating of non-tunneled haemodialysis catheters reduces bacterial colonization: a randomized controlled trial. Nephrol Dial Transplant. 2010; 2: 261-266 6. Zbylut J.Twardowski, Harold L.Moore, University of Missouri, Dialysis Clinic Incorporated, Colombia, Missouri, USA. Side holes at the tip of chronic hemodialysis catheters are harmful, The Journal of Vascular Access 2001; 2: 8-16 Further references 7. Tsai CC, Deppisch R, Forrestale LJ, Ritzau GH, Goehl JG, Voorhees ME. Surface modifying Additives for improved device-blood, compatibility. ASAIO 40(3) M619-M624. 8. Baumann M, Witzke O, Dietrich R, Haug U, Deppisch R, Lutz J, Philipp T, Heemann U. Prolonged catheter survival in intermittend hemodialysis using a less thrombogenic micropatterned polymer modification. ASAIO Journal 2003;49:708-712. 9. Butterly D, Schwab S. Catheter access for hemodialysis: an overview. Seminar in Dialysis 2001;14(6):411-41. Gambro, Everflow Dolphin Protect and Glid In are trademarks of the Gambro Group. Gambro Kathetertechnik Hechingen Zweigniederlassung der Gambro Dialysatoren GmbH Linsenaecker 1 D-72379 Hechingen Tel.: +49 74 71 17 0 00 vascular.access@gambro.com HCEN704_3 2013.04. Gambro Lundia AB Ordering information