M. easurement of ocular blood flow has

Similar documents
The effect of topical /-epinephrine on regional ocular blood flow in monkeys

576 Reports Invest. Ophthalmol. Visual Sci.

Gastrointestinal Blood Flow in the Dog

Organ Blood Flow Measured by Radionuclide-labeled Microspheres During Mechanical Ventricular Assistance

A New Technique for Repeated Measurement of Cardiac Output During Cardiopulmonary Resuscitation

AQUEOUS VEINS IN RABBITS*

(Received 8 March 1965)

A,kCetazolamide lowers intraocular pressure

Photoelectric plethysmography

WHILE it is generally agreed that elevation

T.opically applied corticoids were shown to produce in man an increase in intraocular pressure, a reduction in outflow facility,

THE EYE: RETINA AND GLOBE

Around The Globe in 60 Minutes

RADIAL PERIPAPLLARY CAPILLARIES OF THE RETINA*tt

Uveal Melanoma. Protocol applies to malignant melanoma of the uvea.

THE Bromsulphalein extraction method

CARBONIC ANHYDRASE IN THE VITREOUS BODY*

Quantitative studies of choroidal blood flow by reflective densitometry. Stephen Trokel

UNDERSTAND MORE ABOUT UVEITIS UVEITIS

blood contained within the minute vessels were Fifteen experiments were performed on six normal

Eye Fluids. Dr. Mohamed Saad Daoud

Cardiac Output Technique For Small Animals

Induction of endothelial cell proliferation in rat retinal venules by chemical and indirect physical trauma

Glaucoma. Glaucoma. Glaucoma. Trevor Arnold, MS, DVM, DACVO

Total and Regional Coronary Blood Flow Measured by Radioactive Microspheres in Conscious and Anesthetized Dogs

The Pathology and Pathogenesis of Acute Glaucoma in Dogs. Richard R Dubielzig

The Arterial and Venous Systems Roland Pittman, Ph.D.

Further Studies on the Effect of Arteriovenous Fistulas and Elevations of Sinus Pressure

Haemorrhagic glaucoma

It has been reported that low doses of

Neovascular Glaucoma Associated with Cilioretinal Artery Occlusion Combined with Perfused Central Retinal Vein Occlusion

I n a previous article, 1 the membrane potentials

S,'everal diverse methods have been introduced

LEUKAEMIA*t INFILTRATION OF THE IRIS IN CHRONIC LYMPHATIC. pattemn * Received for pubiication November io, i967.

clearing activity is produced and destroyed in the rat. Both the

(From the Department of Pathology, School of Medicine, Western Reserve University, Cleveland)

The Orbit. The Orbit OCULAR ANATOMY AND DISSECTION 9/25/2014. The eye is a 23 mm organ...how difficult can this be? Openings in the orbit

CIRCULATION IN THE IRIS AND CILIARY PROCESSES

CORNEO-SCLERAL TONOGRAPHY* t BY T. H. HODGSON AND R. K. MACDONALD From the Department of Ophthalmology, University of Toronto, Canada

Case Report: Indocyanine Green Dye Leakage from Retinal Artery in Branch Retinal Vein Occlusion

Surgical Anatomy Ear and Eye. Presenters: Dr. Jim Hurrell and Dr. Dennis McCurnin

The average potassium content during the last 5. solids. This average decrease of 2.2 meq. per 100. initial potassium content of the arteries.

Volume 23 Number 5. Reports 683

XUE HUI Department of Histology& Embryology, Basic Medicine College of Jilin University

OF NORMAL AND SCORBUTIC GUINEA-PIGS

Vision I. Steven McLoon Department of Neuroscience University of Minnesota

by Starling [1914] and Daly [1925].

It has previously been shown that pine

Diffuse infiltrating retinoblastoma

Cardiovascular Physiology

Interrelationship between Angiotensin Catecholamines. Tatsuo SATO, M.D., Masaru MAEBASHI, M.D., Koji GOTO, M.D., and Kaoru YOSHINAGA, M.D.

CHANGES in cerebrospinal fluid pressure

Separation of Responses of Arteries and Veins to Sympathetic Stimulation

OPHTHALMOLOGY AND ULTRASOUND

Indications and Usage: For determining cardiac output, hepatic function and liver blood flow, and for ophthalmic angiography.

Systemic and ocular follow-up after conservative management of an intraocular tumor

Since its introduction as a clinical technique,

Medical School Histology Basics. VIBS 289 lab. Eye

LABORATORY SCIENCES. Effect of Latanoprost on Regional Blood Flow and Capillary Permeability in the Monkey Eye

CT angiography techniques. Boot camp

FOWLER AND COWORKERS have

Transport of amino acids into intraocular fluids and lens in diabetic rabbits. D. V. N. Reddy and V. Everett Kinsey

Studies on the effects of osmotically active substances on the circulation and structure of the retina. Part I. Observations in vivo

Toxicity of intraperitoneal bisulfite

Clues of a Ruptured Globe

The absorption of water from the whole stomach. or one of its parts has not been demonstrated. Many years ago Pavlov showed that water was a

Relaxation responses of aortic rings from salt-loaded high calcium fed rats to potassium chloride, calcium chloride and magnesium sulphate

Special circulations, Coronary, Pulmonary. Faisal I. Mohammed, MD,PhD

Sinus trabeculectomy. Preliminary results of IOO operations

University of Groningen

What was the range of the resting heart rates in males after the exercise programme?

Complement Levels in Normal and Inflamed Aqueous Humor

optic disc neovascularisation

Articles. Ocular microcirculation. Scanning electron microscopic study. Jose Miguel Risco and Waykin Nopanitaya*

THAT RESISTANCE to blood flow in the

THE CHRONIC GLAUCOMAS

Cardiovascular Responses to Exercise

LABORATORY SCIENCES. Depth of Penetration of Scanning Laser Doppler Flowmetry in the Primate Optic Nerve. may be anatomically divided

longitudinal sinus. A decrease in blood flow was observed when the pressure

Grand Rounds. Eddie Apenbrinck M.D. University of Louisville School of Medicine Department of Ophthalmology & Visual Sciences 6/20/2014

612.I73:6I2.I3. mammary and mediastinal vessels tied off. The thoracic wall on the left

The Visual System. Retinal Anatomy Dr. Casagrande February 2, Phone: Office: T2302 MCN

Eye and Ocular Adnexa, Auditory Systems

I t has been demonstrated in in vivo experiments

02/03/2014. Average Length: 23mm (Infant ~16mm) Approximately the size of a quarter Volume: ~5mL

The Circulatory System. Lesson Overview. Lesson Overview The Circulatory System

(D) (E) (F) 6. The extrasystolic beat would produce (A) increased pulse pressure because contractility. is increased. increased

The Inflammatory Role of Endotoxin in Rabbit Gram-Negative Bacterial Endophthalmitis

INVESTIGATIVE OPHTHALMOLOGY. Retinal collateral vessel formation

Pressure-Flow and Pressure-Volume Relations in the Entire Pulmonary Vascular Bed of the Dog Determined by Two-Port Analysis

McHenry Western Lake County EMS System Paramedic, EMT-B and PHRN Optional Continuing Education 2018 #12 Understanding Preload and Afterload

CLASS-y Laser Treats Glaucoma

Regulation of Arterial Blood Pressure 2 George D. Ford, Ph.D.

already been published [O'Connor, 1958 b]. emphasized that the most prominent action of adrenaline on the kidney is to

(From the Physiotogicat Laboratory, Cambridge.)

A LITTLE ANATOMY. three layers of eye: 1. outer: corneosclera. 2. middle - uvea. anterior - iris,ciliary body. posterior - choroid

Dr. D. Y. Patil Medical College, Pimpri, Pune

A Guide to Administering

Pediatric Ocular Sonography

Transcription:

Control of intraocular blood flow. I. Intraocular pressure John J. Weiter, Ronald A. Schachar, and ]. Terry Ernest Measurement of intraocular blood flow has been difficult because of the size and inaccessibility of the ocular blood vessels. Recently, a method was developed using labeled microspheres for studying regional blood flow rates. Using this technique we have begun to study the various parameters which control ocular blood flow. This study confirms the use of labeled microspheres as a valid method for measuring blood flow. We have measured intraocular blood floio in the cat and have shown an inverse relationship between intraocular blood flow and intraocular pressure. M. easurement of ocular blood flow has been hampered because of the size and inaccessibility of the ocular blood vessels. Previous methods of measuring ocular blood flow have yielded a wide range of values and have not approximated normal physiologic conditions. " 7 Recently, a method was developed by Rudolph and Heyman s for the measurement of blood flow by the use of nuclidelabeled microspheres. The reliability of measuring blood flow using radioactive microspheres has been demonstrated. 9 Good agreement was shown for the values of cardiac output as measured by the indocyanine green dye-dilution technique, direct O, Fick method, and the labeled-mi- From the Eye Research Laboratories, The University of Chicago, Chicago,. 60637. Supported in part by United States Public Health Service, National Institutes of Health Grant EY-00792 and EY 00004. Manuscript submitted for publication Dec. 27, 972; manuscript accepted for publication March 7, 973. 327 crosphere method. 0 This technique has recently been applied to measure ocular blood flow in cat, rabbit, and monkey eyes. -' 3 This paper will discuss the effect of intraocular pressure on ocular blood flow in cats using radioactive microspheres. Methods and materials Adult cats weighing 2 to 3 kilograms and of both sexes were used in these studies. The animals were anesthetized with pentobarbital sodium, intraperitoneally, 30 mg. per kilogram. A tracheotomy was performed and the cat was maintained with a respirator. Intraocular pressure was controlled by cannulating the anterior chamber at the limbus with a 2-gauge needle connected to a saline reservoir. In each cat one eye acted as a control (sides were alternated), with its pressure maintained at 7 mm. Hg, while the pressure was altered in the opposite eye from 0 mm. Hg to five times the control pressure. The microspheres were supplied by the Nuclear Products Division of the Minnesota Mining and Manufacturing Company, Minneapolis, Minn. Their exact composition has not yet been released, but they consist of a plastic compound- containing 67 per cent carbon and 23 per cent oxygen. They are referred to as "carbonized microspheres." These carbonized microspheres had a mean diameter of 50 microns ± 5 microns, a specific gravity of.4, and they were labeled with strontium chloride,

328 Weiter, Schachar, and Ernest Investigative Ophthalmology May 973 Table I. Cardiac output and choroidal blood flow (ml./min.) Constant-injection method (Cardio-Green) Sudden-injection method (microspheres) Choroidal blood flow (microspheres) No. 488 520 2.04 No. 2 6 555 2.3 No. 3 46 468.97 Table II. Segmental ocular blood flow expressed as percentage of total ocular flow (mean value of ten cats) Retina Choroid Ciliary body Iris 2% 65% 28% 5% Table III. Relative segmental ocular blood flow per gram of tissue per minute in control animals. These relative blood flow rates are expressed as a ratio of the blood flow to each segment compared to the blood flow of the retina Retina Choroid Ciliary body Iris Nictitating membrane Kidney No. 70 20 6.5 0.4 No. 2 40 4 4 No. 3 65 3 4.5 0.4 8 sn Sr. The 50 micron microspheres were used in order to insure embolization at one pass and prevent recirculation of the microspheres. The radioactive label is incorporated in the spheres and is not merely a coating on their surface. The nuclide label is not lost from the spheres by solution in surrounding fluid. 8 The spheres, as supplied, are suspended in a solution of 20 per cent dextran with a small amount of the surfactant Tween-80, added to prevent aggregation and clumping. There are 5 x 0 (i spheres per 30 c.c. with a total activity of.0 me. The principle of the use of nuclide-labeled microspheres for measuring blood flow is that, if the microspheres are injected into the left heart, their fractional distribution in the peripheral vascular beds will be in proportion to the fraction of cardiac output going to each vascular bed. This is based on the assumption that the microspheres are well mixed in the left heart, are distributed in proportion to blood flow, do not escape to the venous circulation and recirculate, and that impaction in the tissue does not affect the bloodflow rate.!) The left hemithorax of the cat was opened and 0.5 c.c. of labeled microspheres per kilogram of body weight was injected into the left heart. Five minutes after injection the cats were killed by an intracardiac injection of pentobarbital sodium. The eyes of each cat were then enucleated. The muscle insertions and optic nerve were cut flush with the sclera and surface blood was rinsed from the globe. Using an operating microscope, each eye was then dissected into five segments: iris, ciliary body, choroid with tapetum, choroid without tapetum, and retina. The lens, cornea, and vitreous were found to be free of radioactivity and were discarded. As controls, paired kidneys, nictitating membranes, and muscles were utilized. The tissues were then air dried and weighed. Radioactivity was determined using a Packard Auto-Gamma Spectrometer. The gamma ray emission spectral curve for strontium chloride, 85 Sr, was determined. The optimum value was a peak at 502 KEV. A window from 450 to 550 KEV was then selected. Using this window, the background was negligible in relation to the counts of the sample. In order to measure actual blood flow, cardiac output was measured by two methods. The first method used was a constant-injection indicatordilution method employing indocyanine green for the dye dilution. A motor-driven syringe was used to insure constant injection. This standard method for determining blood flow is an application of the Fick method. The Fick method uses the relationship: blood flow (milliliters per minute) equals units of indicator injected per minute per concentration of indicator in samples (in units per milliliter). 4 The second method of measuring blood flow is based on our modification of the sudden-injection indicator-dilution method. 3 In this technique, a sudden injection ( to 2 sec.) was performed into the left atrium of c.c. of labeled microspheres whose total radioactivity was predetermined. Simultaneously, blood was withdrawn by means of a motor-driven syringe at a constant rate of 25 ml. per minute by means of a polyethylene catheter inserted into a femoral artery. The sequence used in comparing these two methods was to obtain repeatable cardiac output values by means of the indocyanine green dye method and then, in the same animal, determine cardiac output by the microsphere sudden-injection method. Results Cardiac output was measured in three cats by sudden- and constant-injection in-

Volume 2 Number 5 Intraocular pressure 329 CILIARY BODY CHOROID WITH TAPETUM 7 34 5 7 34 5 0.4-0.2-.6-.4-.2-.0-0.8-0.6-0.4- CHOROID WITHOUT TAPETUM 7 34 5 Fig.. Graph of the relationship between intraocular pressure and blood flow. The abscissa represents intraocular pressure measured in millimeters of Hg. The ordinate represents relative blood flow expressed as the ratio of radioactivity in the experimental tissue compared to the control tissue. dicator-dilution methods, and it is evident that there is a close correlation between the two techniques (Table I). Using these values for cardiac output, the blood flow to the choroid was determined by measuring the percentage of the total injected labeled microspheres that were entrapped in the choroid. By this method the choroidal blood flow was approximately half of one per cent of the total cardiac output (Table I). Expressed in blood flow per gram of tissue we obtained a value of,300 ml. per 00 Gm. per minute for the choroid. Relative blood flow measurements were made in ten cats. The choroidal blood flow was over three times the blood flow to the kidneys. Using the renal blood flow value (reference flow) of cats of 300 to 400 ml. per 00 Gm. per minute, obtained from the literature 0 the choroidal blood flow would be between,00 to,400 ml. per 00 Gm. per minute. The percentage of total ocular blood flow that went to subdivisions of the uvea and retina is shown in Table II. Note that 65 per cent of ocular blood flow went to the choroid, whereas the retina accounted for only 2 per cent of the total ocular blood flow. The relative blood flow rates also demonstrate the high uveal blood flow compared to the retina. Table III represents blood flow per gram of tissue per minute expressed as a ratio of the blood flow to the retina. The choroidal blood flow is 40 to 70 times the blood flow in the retina. The remainder of the uvea also has a high blood flow in relation to the retina. The change in blood flow produced by varying the intraocular pressure was obtained by comparing the radioactivity of each subdivision of the experimental eye to the corresponding control eye. If there, was no change in blood flow, the ratio was equal to one. In three control animals, there was a variance of two to eight per cent between paired organs and vascular beds. As intra-

Investigative Ophthalmology May 973 330 Welter, Schachar, and Ernest output by a variation of the sudden-injection indicator-dilution method.5 Each experiment can be thought of as consisting of three "systems" of blood flow. System I is the over-all heart-aorta-microcirculation system. System 2 is the syringe-tubing outflow, and System 3 is the uvea-retina microcirculation. The assumption used in this study is that the blood flow in all three of these "systems" is proportionately related to the number of mierospheres in each system or Fig. 2. A photomicrograph of the choroid, demonstrating mierospheres impacted in blood vessels. (x40.) ocular pressure was increased the blood flow to the tissues was decreased and as the pressure was decreased the blood flow increased (Fig. ). The choroid was more responsive to pressure changes than the other tissues, especially when compared to the iris and ciliary body. Discussion This study confirms the value of the use of labeled mierospheres in studying alterations in ocular blood flow. The principle of this method, as previously mentioned, is that, if the mierospheres are injected into the left heart, their fractional distribution in the peripheral vascular beds will be in proportion to the fraction of cardiac output going to each vascular bed. This is based on the assumption that the mierospheres are well mixed in the left heart, are distributed in proportion to blood flow, do not escape to the venous circulation and recirculate, and that impaction in the tissue does not affect the blood flow rate. It has been shown that spheres of 50 microns in diameter meet these criteria. If the flow to any organ (reference flow) is known, the flow to any other organ can be determined. This method has been shown to be an accurate and reliable measure of blood flow.9 The number of mierospheres that impact in the tissues is large (Fig. 2). This is important to eliminate random variation. In this study we determined the cardiac F,/F,/F:, = 2C/SG/SG, where F equals blood flow rate and C equals total concentration (radioactivity) of labeled mierospheres in any system. These systems exist after the labeled mierospheres are injected into the left heart. The labeled mierospheres appear at the outflow from the system in a concentration which is a curvilinear function of time, c(t). The rate at which the mierospheres leave the system at any moment, s, is the product of their concentration at that moment, c(s), and the unknown flow, F. Eventually the entire bolus, q, of injected mierospheres must leave the system. If all products of c(s) and F are summed, this sum must equal the amount of injected mierospheres, or, q = F J»c(t) dt but since the outflow rate is known (by using a calibrated motor-driven syringe) and the radioactivity of the outflow bolus can be measured, the equation can be simplified to F. I 2c where I equals constant outflow through polyethylene sampling tube, and %c equals total concentration (radioactivity) of labeled mierospheres at sampling site. The validity of this technique was verified by previously measuring the cardiac output in each cat by the constant-injection indicatordilution method as shown in Table I. The observation that 65 per cent of the

Volume 2 Number 5 Intraocular pressure 33 total intraocular blood flow went to the choroid might be expected intuitively because of the apparent large relative volume of the choroid (Table II). These values for segmental ocular blood flow are similar to those obtained recently by Aim and Bill 3 using the same technique. More interesting, however, is the fact that per gram of tissue, the choroid has between 40 to 70 times the rate of blood flow that the retina has (Table III). Our present study shows an inverse relationship between intraocular blood flow and intraocular pressure (Fig. ). These results are similar to fluorescein angiography. 7 A decreased blood flow with increased intraocular pressure has been related to the pathogenesis of glaucoma, 7 but we did not perform a separate analysis of disk circulation in this study. The increase in blood flow with decreased intraocular pressure has implications for the treatment of vascular occlusive disease. It may be that lowering the intraocular pressure would be beneficial providing the increased flow is maintained. The nonlinearity of this inverse pressureblood flow relationship implies that there are multiple parameters to regulation of blood flow. It is evident, however, that the intraocular pressure must be controlled if valid studies are to be made of the factors that affect blood flow. We are presently using radioactive microspheres to study the contribution of the sympathetic nervous system to the vascular tonus and the homeostatic regulation of the blood flow to the eye. REFERENCES. Levine, R. Z.: Studies on ocular blood flow in the rabbit, Arch. Ophthalmol. 58: 9, 957. 2. Bill, A.: Quantitative determination of uveal blood flow in rabbits, Acta Physiol. Scand. 55: 0, 962. 3. Pilkerton, R., Bull, P. H., and O'Rourke, J.: Uveal blood flow determined by the nitrous oxide method, INVEST. OPHTHALMOL. 3: 227, 964. 4. Friedman, E., Kopald, H. H., and Smith, T. R.: Retinal and choroidal blood flow determined with krypton-85 in anesthetized animals, INVEST. OPHTHALMOL. 3: 539, 964. 5. Trokel, S.: Measurement of ocular blood flow and volume by reflective densitometry, Arch. Ophthalmol. 7: 88, 964. 6. Christensen, R. E., Posalski, I., Wong, R., et al.: Photoelectric plethysmography. Ocular blood flow measurements in dogs, INVEST. OPHTHALMOL. 0: 247, 97. 7. Fish, M. B., and O'Day, D. M.: Disappearance of intravenous 33 Xenon, Arch. Ophthalmol. 86: 34, 97. 8. Rudolph, A. M., and Heyman, M. A.: The circulation of the fetus in utero, Circ. Res. 2: 63, 967. 9. Neutze, J. M., Wylor, F., and Rudolph, A. M.: Use of radioactive microspheres to assess distribution of cardiac output in rabbits, Am. J. Physiol. 25: 486, 968. 0. Hoffbrand, B. I., and Forsyth, R. P.: Validity studies of the radioactive microsphere method for the study of the distribution of cardiac output, organ blood flow, and resistance in the conscious rhesus monkey, Cardiovasc. Res. 3: 426, 969.. Domenech, R. J., Hoffman, J. I. E., Noble, M. I. M., et al.: Total and regional coronary blood flow measured by radioactive microspheres in conscious and anesthetized dogs, Circ. Res. 25: 58, 969. 2. O'Day, D. M., Fish, M. B., Aronson, S. B., et al.: Ocular blood flow measurement by nuclide-labeled microspheres, Arch. Ophthalmol. 86: 205, 97. 3. Aim, A., and Bill, A.: The oxygen supply to the retina. II. Effects of high intraocular pressure and of increased arterial carbon dioxide tension on uveal and retinal blood flow in cats, Acta Physiol. Scand. 84: 306, 972. 4. Burton, A. C: Physiology and Biophysics of the Circulation: Chicago, 965, Year Book Medical Publishers Incorporated. 5. Handbook of Physiology (eds.): W. F. Hamilton and P. Dow. Circulation, Washington, D. C, 962, American Physiological Society, Vol., Sect. 2, p. 585. 6. Kinter, W. B., and Pappenheimer, J. R.: Role of red blood corpuscles in regulation of renal blood flow and glomerular filtration rate, Am. J. Physiol. 85: 399, 956. 7. Dollery, C. T., Henkind, P., Kohner, E. M., et al.: Effect of raised intraocular pressure on the retinal and choroidal circulation, INVEST. OPHTHALMOL. 7: 9, 968. 8. Ernest, J. T., and Potts, A, M.: Pathophysiology of the distal portion of the optic nerve. II. Vascular relationships, Am. J. Ophthalmol. 66: 380, 968.