MEMO 3D RECHORD. Ready to repair. Guiding standards in Mitral valve repair

Similar documents
ready to repair product brochure PERFORMANCE INNOVATION DESIGN mitral solutions

MEMO 3D. The true reflection of the mitral annulus. Natural physiological 3D motion

MEMO 4D Reshaping Mitral Repair

MITROFLOW VALSALVA CONDUIT TM

CROWN PRT. Inservice implantation guide

REDUCING THE IMPACT OF SURGERY AND FACILITATING FASTER RECOVERY

SOLO SMART. The smart way to return to life. Native-like performance now with stented-like implantability

Posterior leaflet prolapse is the most common lesion seen

CROWN PRT. The crowning touch. Experience designs performance

Really Less-Invasive Trans-apical Beating Heart Mitral Valve Repair: Which Patients?

Surgical Repair of the Mitral Valve Presenter: Graham McCrystal Cardiothoracic Surgeon Christchurch Public Hospital

The Key Questions in Mitral Valve Interventions. Where Are We in 2018?

Χειρουργική Αντιμετώπιση της Ανεπάρκειας της Μιτροειδούς Βαλβίδας

Percutaneous mitral valve repair/replacement. Jan Van der Heyden MD, PhD St.Antonius Hospital Nieuwegein

Atrioventricular valve repair: The limits of operability

PROVEN PLUS. Introducing the Avalus Aortic Valve by Medtronic.

CONVENTIONAL ADULT CANNULAE

MICS & FEMORAL CANNULAE

CONVENTIONAL ADULT CANNULAE

UNIRING, Universal Annuloplasty System Overview and Surgical Guidelines

Professor and Chief, Division of Cardiac Surgery Chief Medical Officer, Harpoon Medical. The Houston Aortic Symposium February 23-25, 2017

Percutaneous mitral annuloplasty. Francesco Maisano MD, FESC San Raffaele Hospital Milano, Italy

THE FOLDING LEAFLET. Rafael García Fuster. Cardiac Surgery Department University General Hospital of Valencia

Outcomes of Mitral Valve Repair for Mitral Regurgitation Due to Degenerative Disease

Despite advances in our understanding of the pathophysiology

Echocardiographic Evaluation of Primary Mitral Regurgitation

ThruPort Ergonic Minimal Incision Instrumentation

Cannula Portfolio NEW

TAVI Versus Suturless Valve In Intermediate Risk Patients

Technical aspects of robotic posterior mitral valve leaflet repair

Hani K. Najm MD, Msc, FRCSC FACC, FESC President Saudi Society for Cardiac Surgeons Associate Professor of Cardiothoracic Surgery King Abdulaziz

Valve Analysis and Pathoanatomy: THE MITRAL VALVE

Eva Maria Delmo Walter Takeshi Komoda Roland Hetzer

Basic principles of Rheumatic mitral valve Repair

The clinical problem of atrioventricular valve regurgitation

PATIENT BOOKLET MEDTRONIC MITRAL AND TRICUSPID HEART VALVE REPAIR

Lyoplant Onlay. Adding another layer of confidence to every procedure. Aesculap Neurosurgery

Role of Sutureless Valves in the Surgeon s Armamentarium Prof. Dr Malakh Shrestha Vice Chair, Director of Aortic Surgery Cardiothoracic,

Basic Principles of Degenerative Mitral Valve Repair Technical Aspects and Results. Manuel Antunes Coimbra-Portugal

Accepted Manuscript. A Bad Trade: Mitral Regurgitation for Mitral Stenosis and Atrial Fibrillation

Joseph E. Bavaria, M.D. Roberts Measy Professor and Vice Chief CardioVascular Surgery Director: Thoracic Aortic Surgery Program University of

Cowen and Company Annual Healthcare Conference 2018

National Institute for Health and Care Excellence IP865/2 Sutureless Aortic Valve Replacement for aortic stenosis

Mitral Programme Update

Replacement of the mitral valve in the presence of

Experience with 500 Stentless Aortic Valve Replacements

The Edge-to-Edge Technique f For Barlow's Disease

Sorin Group. Marco Chiadò Piat, VP Corporate Development. Goldman Sachs European Medtech and Healthcare Services 5-6 September 2007

The stentless bioprosthesis has many salient features that

Annular Stabilization Techniques in the Context of Aortic Valve Repair

SURGICAL AND TRANSCATHETER MITRAL VALVE REPLACEMENT VS. REPAIR: COMPETITION OR SYNERGY

Chordae replacement versus leaflet resection in minimally invasive mitral valve repair

(Ann Thorac Surg 2008;85:845 53)

Hani K. Najm MD, Msc, FRCSC, FRCS (Glasgow), FACC, FESC President of Saudi Heart Association King Abdulaziz Cardiac Centre Riyadh, Saudi Arabia.

Percutaneous Mitral Valve Repair

Percutaneous Mitral Valve Intervention: QuantumCor Device

Management of Difficult Aortic Root, Old and New solutions

Repair or Replacement

Chart a course for meniscal preservation

Historical perspective R1 黃維立

Hemodynamics Benefit of Supra-Annular Design in Failed Bio-Prosthetic Valves

The Versatile Polyaxial Solution for the Universal Spine Systems. USS II Polyaxial. Surgical Technique

Surgical Mininvasive Approach for Mitral Repair Prof. Mauro Rinaldi

Cleveland Clinic Innovation Center

Indications and Late Results of Aortic Valve Repair

MINIMALLY INVASIVE MITRAL VALVE REPAIR NEW YORK UNIVERSITY MEDICAL CENTER, NEW YORK, NEW YORK Broadcast March 9, 2005

Overview of Surgical Approach to Mitral Valve Disease : Why Repair? Steven F. Bolling, MD Cardiac Surgery University of Michigan

Imaging to select patients for Transcatheter TV

Rheumatic fever and rheumatic heart disease still remain a. The Rheumatic Mitral Valve and Repair Techniques in Children. Afksendiyos Kalangos

Transcatheter Mitral & Tricuspid Therapies. Bernard J. Zovighian Corporate Vice President

A new era in cardiac valve surgery has begun...

Percutaneous Valve Interventions. Percutaneous Valve Interventions

Index. B B-type natriuretic peptide (BNP), 76

Late secondary TR after left sided heart disease correction: is it predictibale and preventable

Visit Linvatec.com today to learn more. Surgical Technique: Sequential Meniscal Running Stitch

The Tricuspid Valve: The Not So Forgotten Valve. Manuel J Antunes Cardiothoracic Surgery Coimbra, Portugal

Surgery For Ebstein Anomaly

Part II: Fundamentals of 3D Echocardiography: Acquisition and Application

Aortic valve repair: Techniques and Pitfalls. Allan Stewart, MD Columbia University Medical Center New York, NY

Aortic root enlargement is an invaluable surgical technique

Cases of mitral valve causing mitral regurgitation: the MV prolapse spectrum CASE

Tricuspid leaflet repair: innovative solutions

INSTRUMENTS. Design Rationale

Mitral Valve Repair for Functional Mitral Regurgitation- Description of A New Technique and Classification System

Biomimetic PEARL. Product catalogue

Petite Wound Drainage System. 13mm CWV Drainage System. CWSump. CWV with Trocar

Joseph E. Bavaria, M.D. Roberts Measy Professor and Vice Chief CardioVascular Surgery Director: Thoracic Aortic Surgery Program University of

-vita THORACIC 3G. Stent Graft System SOLUTIONS FOR VASCULAR DISEASE

Disclosure Statement of Financial Interest Saibal Kar, MD, FACC

Surgical Technique VPLWK QHSKHZ 1$126 1HFN 3UHVHUYLQJ +LS 6WHP 1716-e_NANOS_OPT.indd :27

Knee Preservation System

Introduction. Aortic Valve. Outflow Tract and Aortic Valve Annulus

2017 Cardiovascular Symposium CARDIAC SURGERY UPDATE: SMALLER INCISIONS AND LESS COUMADIN DAVID L. SAINT, MD

AVR with Sutureless Valves State of the Art

Ο ΡΟΛΟΣ ΤΩΝ ΚΟΛΠΩΝ ΣΤΗ ΛΕΙΤΟΥΡΓΙΚΗ ΑΝΕΠΑΡΚΕΙΑ ΤΩΝ ΚΟΛΠΟΚΟΙΛΙΑΚΩΝ ΒΑΛΒΙΔΩΝ

Sutureless Mitral and Tricuspid Clamp Valves

Minimally invasive valve sparing mitral valve repair the loop technique how we do it

Recurrent mitral regurgitation after repair: Should the mitral valve be re-repaired?

JOINT MEETING 2 Tricuspid club Chairpersons: G. Athanassopoulos, A. Avgeropoulou, M. Khoury, G. Stavridis

Tricuspid Valve Repair for Ebstein's Anomaly

Transcription:

MEMO 3D RECHORD TM Ready to repair Guiding standards in Mitral valve repair

CARDIAC SURGERY SOLUTIONS A 45-year long history of innovative records in cardiac surgery LivaNova s relentless commitment to providing innovative solutions through advanced technologies and breakthrough therapeutic treatments for cardiovascular diseases is an innate trait of its DNA and has brought the company to become world leader in the field of cardiac surgery. Hlm Carbofilm Bicarbon Solo Smart Inspire Crown PRT Perceval Carbomedics Top Hat Gdp Monitor Memo 3D ReChord 2

MEMO 3D RECHORD TM MEMO 3D RECHORD TM LivaNova offers a portfolio of solutions to all types of mitral valve disease Its latest innovation is Memo 3D ReChord TM, the ultimate repair device designed to deliver better patient outcomes while facilitating the surgical procedure. Memo 3D ReChord TM is every surgeon s invaluable partner, its innovative chordal guiding system makes artificial chordae replacement a routine procedure 1. 1. Glauber et al., Ann Cardiothorac Surg. 2015;4 (3):298-300 3

MITRAL SOLUTIONS Mitral valve repair is now the most frequently performed surgical procedure for mitral valve disease but repair and replacement may be applied to different subsets of patients. (Daneshmand et al., Ann Thorac Surg 2009;88:1828 37) Each patient requires a tailored care, and every surgeon needs in his hands the best solution to meet this expectation. Therefore to address the surgical need to have the best solution fitting each patient and surgeon requirements, only a truly and integrated offering can respond. LivaNova Mitral Solutions offers a full range of devices for each and every need: flexible, rigid and semirigid annuloplasty rings for mitral repair and both biological and mechanical prostheses for mitral valve replacement. 4

MEMO 3D RECHORD TM Memo 3D ReChord Memo 3D Sovering Sovering Band Sovering Tricuspid Band Sovering Mini Band Carbomedics Annuloflex Carbomedics Annuloflo Bicarbon Fitline Carbomedics Optiform Carbomedics Standard Pediatric Pericarbon More 5

Innovation rings true 6

MEMO 3D RECHORD TM Introducing MEMO 3D LivaNova Memo 3D annuloplasty ring has been engineered with the aim to create a unique and optimal solution across the entire spectrum of mitral valve repair. The unique core of Memo 3D provides a firm support to the mitral annulus while allowing the natural physiological 3D motion that truly reflects the native mitral annulus. The innovative design of Memo 3D provides reproducible results, predictable outcomes, and superior performance combined with enhanced hemo and biocompatibility. 7

DESIGN Unique to its core 8

MEMO 3D RECHORD TM Unique super-elastic alloy core The exclusive alloy core cell design is a laser-cut one-piece structure that allows truly physiological annular dynamics. The precision laser-cutting technology is also used to obtain LivaNova s innovative Perceval sutureless aortic prosthesis. Shape Memory The superelastic alloy core remembers a prefixed shape after geometric deformation and can be flexed back and forth without losing its original form. Memo 3D s shape memory provides consistent recovery of the systolic profile and restores the natural systolic diameter ratio. The Right Balance of Rigidity and Flexibility to Support any Repair Memo 3D, semi-rigid annuloplasty ring, is truly the only ring you ll ever need whether you re looking for stability to support the annulus or flexibility of movement. The innovative superelastic alloy cell structure is optimized to provide a progressive degree of flexibility from the anterior to posterior portions of the ring to allow physiological, three-dimensional motion to accommodate native mitral annulus dynamics and to reduce stress on the repair. Rigid Flexible Three layer structure Ease of implant with superior visualization, placement and attachment while ensuring a perfect annular fit. The oval silicone sheath provides easy suturability with conformable needle penetration. 9

PERFORMANCE The true reflection of the mitral annulus 10

MEMO 3D RECHORD TM Systolic remodeling and diastolic dynamics concept Truly physiological three-dimensional motion of the mitral annulus with a natural anterior/posterior to lateral/lateral relationship to maximize blood flow, 2,3,4 even after more than five years from implantation. 5 Systolic Remodelling Maximized Coaptation and Reduced Stress Nishi et al. Circulation. 2013;128:A16940 Diastolic Dynamics Maximized Hemodynamics Ryomoto et al. Ann Thorac Surg. 2014 Feb;97(2):492-7 Physiologic saddle shaping concept The true physiological 3D motion of the ring during the cardiac cycle preserves the natural non-planar saddle shape geometry of the annulus. Recent clinical data has demonstrated that Memo 3D is able to accommodate the physiological saddle shape of the mitral annulus throughout the cardiac cycle upon implantation. 2,3,4 Carbofilm TM coating The bio/hemocompatible properties of the unique Carbofilm TM coating allows complete endothelialization, prevents inflammatory reaction and scar tissue formation. Designed to maintain physiological dynamics in the long term. 5,6 2. Ryomoto et al., Ann Thorac Surg 2014;97:492 8 3. Nishi et al., Circulation 2013; 128: A16940 4. Wan et al., Ann Cardiothorac Surg 2015;4(3):261-265 5. Santarpino G, Pfeiffer S, Fischlein T, Int J Cardiol. 2011 Dec 14 6. Della Barbera et al., Cardiovascular Pathology 14 (2005) 96-103 11

IMPLANTATION Ease of use and implant 12

MEMO 3D RECHORD TM PERFECT ANNULAR FIT AND VISUALIZATION: Silicone ring for easy needle penetration and white sutures as guidelines The Memo 3D semirigid annuloplasty ring facilitates easier implantation with superior visualization, placement, and attachment. The oval cross section of the silicone sheath provides more material for easier needle penetration. White suture guidelines on the underside of Memo 3D provide an excellent visual reference point for easier suturing. Oval silicone crosssection for easy needle penetration White suture guideline to aid suture placement New holder The new, versatile holder has been designed to facilitate the implantation procedure. The ring is attached to a template that can be removed together with the holder or temporarily left in position to be removed after knot tying. New MICS sizers The new set of sizers have been specifically designed to optimize sizing also during minimally invasive procedures where surgical site visualization is compromised. 13

INNOVATION Guiding Standards MEMO 3D ReChord TM is the ultimate Repair device technology designed to deliver better patient outcomes while facilitating the surgical procedure, thanks to its innovative chordal guiding system that makes artificial chordae replacement a routine procedure. MEMO 3D ReChord TM incorporates a series of loops in the posterior region that act as temporary reference elements for easier sizing of chords length. The innovative chordal guiding system promotes standardized chord replacement, offering reproducible results while accelerating procedure times. 1 Facilitating and standardizing the implantation procedure to promote reproducible results. 1. Glauber et al., Ann Cardiothorac Surg. 2015;4 (3):298-300 14

MEMO 3D RECHORD TM Implantation procedure 1 2 Mitral regurgitation: chordal rupture Annuloplasty ring sizing 3 4 Chord should be passed through the window Anchoring of the artificial chord 5 6 Ring parachuting and implantation Cut at the P2 area and remove the holder 15

Implantation procedure 7 Tie the knots tight 8 Artificial chord through the reference element on the Memo 3D Rechord 9 10 Knots are tied at the annular level Step 1: pull the blue thread first No cutting is needed Step 2: then pull the yellow thread 11 12 Truly physiological 3D motion of the mitral annulus Fast, reproducible procedures for durable patient outcomes 16

New holder MEMO 3D RECHORD TM One-step removal Remove all with one single cut: fast removal, user friendly (one cut only at the P2 area). 1 2 Cut and remove the holder Tie the knots tight Two-step removal For those that prefer to have a rigid frame when tying the knots (avoid purse string effect and stress on the structure) and to protect the loops from the knotpusher when addressing the valve in MICS. Specifically designed handle for an easy removal of the LOW PROFILE TEMPLATE with forceps. 1 Cut Cut 2 3 Tie the knots tight Cut Cut at the P2 area and remove the template with forceps 17

Clinical highlights from the first published experience 1 The length of the neochordae obtained will exactly match the plane of the native annulus at the coaptation point. This is a simple and reproducible technique, suitable for both anterior and posterior leaflet prolapse, which restores leaflet motion and ensures a large surface of coaptation. According to our experience, the temporary chordal guide system allows a correct implantation of PTFE neochordae without the need for chordal measurement, short operative times and doesn't require a long learning process. In our opinion, its use might standardize the respect rather than resect mitral valve repair technique, further facilitating a MIMV surgical approach 1. Glauber et al., Ann Cardiothorac Surg. 2015;4 (3):298-300 18

MEMO 3D RECHORD TM Product ordering information Memo 3D ReChord TM semirigid annuloplasty ring: superelastic alloy core covered by silicone and polyester fabric coated with Carbofilm TM Ordering Number Size A (mm) Orifice area (cm 2 ) ICV1330 24 24 2.30 ICV1331 26 26 2.78 ICV1332 28 28 3.28 ICV1333 30 30 3.78 ICV1334 ICV1335 32 34 32 34 4.39 4.98 A ICV1336 36 36 5.67 ICV1337 38 38 6.34 Accessories ordering information (not provided sterile) Catalog Number Name Description ICV0664 Uni Handle Universal Bendable Handle ICV1342 Extended Uni Handle Universal Bendable Handle for MICS Instrument Set ICV1340 Annuloplasty Ring Sizer Set Complete Sizer Set (24 to 38 mm) Uni Handle ICV1343 Annuloplasty Ring Accessory Tray Empty Instrument Tray Extended Uni Handle Memo 3D Rechord Sizer Standard and MICS 19

12/15 RE0210203/C Manufactured by: Sorin Group Italia Srl A wholly-owned subsidiary of LivaNova Plc Via Crescentino - 13040 Saluggia (VC) Italy Теl: +39 0161 487472 - Fax: +39 0161 487316 info.cardiacsurgery@livanova.com Please always refer to the Instructions For Use (IFU) manual provided with each product for detailed information, warnings, precautions and possible adverse side effects. 2015 LivaNova all rights reserved.