The injectable, self-setting calcium phosphate bone graft substitute.

Similar documents
Graftys. Cross-selling. Indications. Comparison. Basic Science. Graftys 415 rue Claude Nicolas Ledoux Aix en Provence Cedex 4

Calcium Phosphate Cement

Graftys Quickset & Graftys HBS use in plateau tibial fracture

Bone Void Filler. Callos. The Next Generation in Calcium Phosphate Cement A COLSON ASSOCIATE

Surgical Technique Guide. Impact & Inject Formulations

Trauma fixation choices chart your fracture

ADVANCED BONE GRAFT SYSTEM OVERVIEW

CERAMENT BONE VOID FILLER

Calcium Phosphate Bone Void Filler TECHNIQUE GUIDE

Cementing better outcomes

POWER TO RESTORE WITHOUT LEAVING A TRACE. The only remaining evidence of the trauma

chronos Inject. Synthetic Bone Substitute Injectable, Osteoconductive, Resorbable.

Explore the possibilities

Biomaterials Line. MIS Corporation. All Rights Reserved.

A better knee replacement begins with you

Injectable Synthetic Bone Substitute

Callos Bone Void Filler

Product Information. MIS Corporation. All Rights Reserved.

Specifications guide ECHELON. Hip System

Product Highlights. TRUREPAIR Solutions

Void Fillers: White Paste or Bone

Perfect partner for your infection management strategy

chronos Bone Void Filler. Beta-Tricalcium Phosphate ( β-tcp) bone graft substitute.

Knee spanning solutions

Inion BioRestore. Bone Graft Substitute. Product Overview

User FAQ Graftys QuickSet & HBS

Spine A Preliminary Study of the Efficacy of Beta-Tricalcium Phosphate as a Bone Graft Expander for Instrumented Posterolateral Fusions

Indications. Neuro Surgery. Plastic Surgery. ENT Surgery. Oral Maxillofacial Surgery

STIMULAN POWER TO TRANSFORM OUTCOMES

One system for all revision types

STIMULAN POWER TO TRANSFORM OUTCOMES

Surgical Technique. VISIONAIRE Disposable Instruments for the LEGION Total Knee System

The TRIGEN SURESHOT system has my back.

Isolated Subtalar or Talonavicular Fusion Has Failed. Now What?

Innovative Range of Regenerative Solutions

Case Study: David. Conditions Treated Femoral Neck Fracture with Avascular Necrosis of the Hip. Age Range During Treatment 16 Years

HydroSet. Fast-setting HA bone substitute

Clinical. Solutions. Synthes Solutions. Foot and Ankle.

Bone Grafting and Bone Graft Substitutes. Original Author: James Krieg, MD Revision Author: David Hak, MD Last Revision May 2010

Direct. DirectInject Stryker CMF. Craniomaxillofacial. Operative Technique

CASE REPORT. Bone transport utilizing the PRECICE Intramedullary Nail for an infected nonunion in the distal femur

CELLPLEX TCP SYNTHETIC CANCELLOUS BONE

Increasing surgical freedom Restoring patient function

Design Rationale. ECHELON Primary Hip System

Radiology Case Reports. Bone Graft Extruded From an Intramedullary Nail Tract in the Tibia. Penelope J. Galbraith, M.D., and Felix S. Chew, M.D.

Specification Summary

CASE STUDY: PRO-DENSE Injectable Regenerative Graft Used to Backfill a Bone Cavity Following Resection of a Giant Cell Tumor

INTERTAN Nails Geared for Stability

Surgical Technique. Targeter Systems Overview

Readigraft Cancellous Block

1:00 pm Welcome and Introduction Paul Tornetta III, MD and J. Tracy Watson, MD

THE ESSENTIALS IN BONE GRAFTING BRIDGING MEDICAL GAPS

Unified Classification System (UCS) for peri-prosthetic fractures (PPFx)

PRO-DENSE BONE GRAFT SUBSTITUTE

Surgical Technique. Foot and Ankle Technique Guide Ankle Syndesmosis Repair, Operative Technique

Inion OTPS TM. The Biodegradable Solution. lnion OTPS TM Plating Systems. Product description

Surgical Care at the District Hospital. EMERGENCY & ESSENTIAL SURGICAL CARE

End-To-End Solution Posterior Lumbar. A comprehensive offering of complementary products.

Metha Short Hip Stem System

YEAR DATA STEP. Proven results in cartilage repair. CARGEL Bioscaffold. Supporting healthcare professionals for over 150 years

28 Surgical Technique

PFNA. With Augmentation Option.

Norian Drillable: A Competitive Analysis

PFNA. With Augmentation Option.

B U I L D S T R O N G B O N E F A S T

Regenerex Porous Titanium Construct. Knees Hips Extremities Cement and Accessories PMI Trauma Technology

Advanced instrumentation for surgical simplicity

*smith&nephew SBG Anatomical Hip Stem Prosthesis. Product Information

NEW FIXATION STRATEGIES FOR OSTEOPOROTIC BONE

2018 Professional Education Course Calendar

3D printed. Patient Specific. titanium alloy truss implants

Precisely locate anatomic femoral ACL insertion sites 1. ACUFEX PINPOINT Anatomic ACL Guide System

STRENGTH FOR LIFE BONE CEMENTS FOR VERTEBRAL CONSOLIDATION

4/28/2010. Fractures. Normal Bone and Normal Ossification Bone Terms. Epiphysis Epiphyseal Plate (physis) Metaphysis

Fibula bone grafting in infected gap non union: A prospective case series

CALCIUM-BASED NEUTRAL AND BIORESORBABLE SELF-SETTING INJECTABLE BONE PUTTY. Ping Luo and Kenneth Trauner* Berkeley Advanced Biomaterials, Inc.

Failed Subtrochanteric Fracture How I Decide What to Do?

FLT105 12/02.

AO / Synthes Proximal Posterior Medial Tibia Plate. Tibial Plateau Fx. Osteosynthesis

CALLoSr. Calcium Phosphate Cement

SPINE BIOMATERIALS Crop Bleed

Unicameral bone cysts are benign, fluid-filled cavities

THE NEW STANDARD OF EXCELLENCE IN BIOMATERIALS. Collagenated heterologous cortico-cancellous bone mix + TSV Gel GTO I N S P I R E D B Y N A T U R E

Treatment of Distal Radius Bone Defects with Injectable Calcium Sulphate Cement

A new approach with an in-situ self-hardening grafting material

PLR. Proximal Loading Revision Hip System

Lawrence A. DiDomenico, DPM, FACFAS

Locked Plating: Clinical Indications

ctive Bone Bonding Bone Regeneration Osteostimulation*

2018 Professional Education Course Calendar

James T. Mazzara, MD Continuing Medical Education 10/8/2006

Orthopedic & Sports Medicine, Bay Care Clinic, 501 N. 10th Street, Manitowoc, WI Procedure. Subtalar arthrodesis

Advice sheet for Surgeons and Radiologists. Radiographic appearance of CERAMENT

D-RAD SMART PACK Plating System. A series of case studies

THE NEXT FRONTIER OF BONE REGENERATION

Resorbable Orthopedic Fixation System

A locking plate system that expands a surgeon s options in trauma surgery. Zimmer NCB Plating System

PRO-STIM Injectable Inductive Graft TECHNICAL MONOGRAPH

Shoulder Position: Supine arm in the neutral position. Collateral arm above head Indication: fracture humerus, fracture scapula

Transcription:

The injectable, self-setting calcium phosphate bone graft substitute. With a porous architecture similar to natural bone. STRUCSURE CP Bone Graft Substitute

Because simplicity matters STRUCSURE CP Bone Graft Substitute is an advanced, injectable, hard-setting bone graft substitute designed to gradually resorb while being replaced with natural bone. STRUCSURE CP Bone Graft Substitute is mixed in a unique dualchambered syringe that minimizes preparation efforts prior to use and includes a dispenser gun with a seven-gauge cannula for precise placement of material. This allows for maximized OR efficiency. Benefits of STRUCSURE CP mixing system All-inclusive closed mixing and delivery system ensures sterility Pre-measured components eliminate pre-setup and require just two minutes of preparation time Mixing technique is simple and reproducible Material-saving design reduces waste during injection Components are pre-measured and pre-loaded in the syringe s dual chambers Dispenser gun allows for precise placement of material 3-inch cannula allows for minimally invasive access and fill of large defects

Indications Shoulder Replacement Proximal Humerus Fx Benign Bone Cysts 5 cc to 8 cc Iliac Crest Backfill Osteolytic Lesion Revision Hip Replacement 30 cc to 40 cc Distal Radius 5 cc to 8 cc Core Decompression Primary Hip Replacement 5 cc to 8 cc Periprosthetic Fx Distal femur Fx 8cc to 10cc Primary Knee Replacement 5 cc to 8 cc Revision Knee Replacement Fx 20 cc to 30 cc Tibial Plateau Fx Pilon and Ankle Fx Calcaneus Fx Available in 5, 8 and 16 cc sizes Fracture void size will vary with patients Trauma indications Recon indications Recon indications

Because you need clinical versatility STRUCSURE CP Bone Graft Substitute is composed of a proprietary calcium phosphate mixture. The combination of calcium phosphate powder and a lowmolecular-weight polymer creates a porous scaffold ideal for bone growth. The STRUCSURE CP material gradually remodels into bone. STRUCSURE CP Bone Graft Substitute provides a bone grafting option that addresses your specific clinical needs. Global porosity of 70% and 10% macroporosity to enable cellular in-growth. Mechanical strength of 24 MPa to prevent subsidence in metaphyseal defects. Injectability and radioopacity to ensure complete void filling and bone apposition. Gradual setting profile provides flexibility to inject around hardware or place hardware through STRUCSURE CP material without concern of fracturing the material. Non-exothermic reaction to prevent cell damage. Cohesive nature to allow implantation in moist defects without concern for washout. 30 minutes 7 days Formation of Calcium-Deficient Apatite Crystals

Because you need it to work. STRUCSURE CP Bone Graft Substitute, with its crystalline structure similar to natural bone and its enhanced porosity, is designed to be gradually remodeled into bone. Case studies performed by Dr. Sébastien Parratte, Department of Orthopedic Surgery, Ste Marguerite University Hospital, Marseille, France. CASE STUDIES Complex Tibial Plateau Fracture A complex tibial plateau fracture was treated with plates and screws along with an injection of STRUCSURE CP Bone Graft Substitute. Results showed good osseointegration between the biomaterial and the bone throughout the twoyear follow-up period, with resorption of the biomaterial and replacement with newly-formed bone over time. Preoperative X-ray 3 Months Postoperative X-ray 2 Years Postoperative X-ray Proximal Humeral Fracture A proximal fracture with head impaction was treated with intramedullary nailing and injection of STRUCSURE CP Bone Graft Substitute. One month postoperatively, good osseointegration and a homogenous interface between the implant, cement and bone was observed. At two years, good healing was seen with no delimitation between bone and STRUCSURE CP material. The patient had a Constant score of 89 and had resumed normal activities. Preoperative X-ray 1 Month Postoperative X-ray 2 Years Postoperative X-ray Calcaneum Necrosis Bone Filling A defect of the greater tuberosity of the calcaneus was treated with injection of STRUCSURE CP Bone Graft Substitute (red circle indicates treatment site). Very good bony integration was seen six months postoperatively, and the patient reported being pain-free. Preoperative X-ray 6 Months Postoperative X-ray

Learn more about this revolutionary system at www.strucsurecp.com Ordering Information STRUCSURE CP kit includes syringe, dispenser gun and 7-gauge cannula Reference # Description 717805 STRUCSURE CP 5 cc Kit 717808 STRUCSURE CP 8 cc Kit 717816 STRUCSURE CP 16 cc Kit Smith & Nephew, Inc. 7135 Goodlett Farms Parkway Cordova, TN 38016 USA www.smith-nephew.com T +1 901 396 2121 Information: +1 800 821 5700 Orders and Inquiries: +1 800 238 7538 Trademark of Smith & Nephew. 2012 Smith & Nephew. All rights reserved. Printed in USA. 08/12 10601037 Rev. A