Meta-analysis Complications following dorsal versus volar plate fixation of distal radius fracture: A meta-analysis Journal of International Medical Research 41(2) 265 275! The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalspermissions.nav DOI: 10.1177/0300060513476438 imr.sagepub.com Jie Wei 1, Tu-Bao Yang 1, Wei Luo 2, Jia-Bi Qin 1 and Fan-Jing Kong 1 Abstract Objectives: A meta-analysis to compare complication rates following volar or dorsal surgical fixation of distal radius fracture. Methods: A detailed search of PubMed Õ /MEDLINE Õ was undertaken to identify randomized and nonrandomized controlled trials published before 25 August 2012 that compared volar with dorsal fixation, in patients with distal radius fracture. Results: A quantitative meta-analysis of 12 trials (952 patients) was performed. There was no between-group difference in the overall rate of complications. Volar fixation was associated with significant increases in neuropathy (relative risk [RR] 2.19; 95% confidence intervals [CI] 1.27, 3.76) and carpal tunnel syndrome (RR 4.56; 95% CI 1.02, 20.44), and a reduction in tendon irritation, compared with the dorsal approach (RR 0.38; 95% CI 0.17, 0.86). Conclusions: Dorsal fixation offers a lower risk of neuropathy and carpal tunnel syndrome than the volar approach, but a higher risk of tendon irritation. Patients with a distal radius fracture can expect similar outcomes after volar or dorsal surgery. Keywords Complication, distal radius fracture, dorsal, meta-analysis, volar, fixation Date received: 19 October 2012; accepted: 11 November 2012 Introduction Fractures of the distal radius are very common, comprising around 20% of all fractures. 1 A substantial proportion of people who experience injuries to the distal radius are otherwise healthy. 2 The goals of treatment are to restore articular surface congruency, including radial height, radial inclination and palmar tilt. 3,4 Depending on 1 Department of Epidemiology and Health Statistics, School of Public Health, Central South University, Changsha, Hunan Province, China 2 Department of Orthopaedics, Xiangya Hospital, Central South University, Changsha, Hunan Province, China Corresponding author: Dr Wei Luo, Department of Orthopaedics, Xiangya Hospital, Central South University, 87 Xiangya Road, Changsha, Hunan Province 410008, China. Email: 394345006@qq.com
266 Journal of International Medical Research 41(2) the displacement of the distal fragment, there is an increasing use of locked plate fixation by either a dorsal or volar approach: such fixation provides better reduction and stability, allows earlier mobilization and greatly improves the outcome compared with conventional T-plate fixation. 5 Dorsal fixation allows direct exposure and reconstruction of the joint by a capsular incision, 6 but requires dissection of the extensor retinaculum and subsequent plate positioning beneath this tendon, which often leads to tendonitis or tendon rupture. 7 As an alternative, volar fixation provides biomechanical stability for dorsally displaced and comminuted fractures. The significant softtissue dissection required with this procedure results in a high incidence of neuropathy and carpal tunnel syndrome, however. 8 Open reduction and internal fixation is one of the most commonly used surgical techniques for distal radius fracture. 9,10 The purpose of this meta-analysis was to investigate the benefits and complications of volar and dorsal surgical fixation of distal radius fracture. Materials and methods Search strategy Searches of the PubMed Õ and MEDLINE Õ databases were independently performed by two investigators (J.W. and T-B.Y.) using the following search terms (palmar OR volar OR thenar) AND (dorsal) AND (Barton fracture OR Colles fracture OR Smith fracture OR distal radius fracture OR distal radial fracture OR fractures of distal radius). Databases were searched from the earliest records up to and including 25 August 2012, without language restrictions. Inclusion and exclusion criteria Studies were considered eligible if they met the following criteria: (i) patients had a diagnosis of distal radius fracture, irrespective of diagnostic criteria, aetiology, associated pathology, sex or age; (ii) comparison of volar and dorsal approaches; (iii) data regarding complication rate provided; (iv) study reported relative risk (RR) and corresponding 95% confidence intervals (CI) or data required to calculate them. Exclusion criteria were: (i) case reports; (ii) reviews; (iii) animal studies; (iv) cadaver studies; (v) data unavailable for metaanalysis. Data extraction and quality assessment The following data were independently extracted and recorded by two investigators (J.W. and T-B.Y.): study characteristics (first author, year of publication, country of origin); implant type; sample size; numbers of patients with volar approach and dorsal approach; mean age; sex distribution; duration of follow-up; study design; number of complications. A complication was defined as an adverse treatment event recorded by the author(s) of the study. The main outcome measure of the meta-analysis was the overall complication rate. Methodological quality of the selected studies was independently assessed by two investigators (W.L. and J.W.) using the methodology quality assessment scale for randomized clinical trials 11 and the nonrandomized study methodology quality assessment scale for nonrandomized trials. 12 Statistical analyses Data were summarized using RRs and their corresponding 95% CIs. Homogeneity of RRs across studies was tested by the Q statistic with significance set at P < 0.01. The I 2 statistic was used as a second measure of heterogeneity, with 0% indicating no evidence of heterogeneity and 25%, 50% and 75% indicating low, moderate and high heterogeneity, respectively. A randomeffects model was used in the case of
Wei et al. 267 significant heterogeneity (P < 0.10 or I 2 > 50%); in all other cases, a fixed-effects model was used. Sensitivity analysis was used to examine the influence of various exclusion criteria on overall effect size. Publication bias was assessed using Begg s test 13 and funnel plots. All statistical analyses were performed using RevMan software, version 5 (The Cochrane Collaboration, Oxford, UK). A P-value < 0.05 was considered statistically significant, unless otherwise specieed. Results The literature search initially identified 388 citations, of which 12 were eligible for inclusion in the meta-analysis (total n ¼ 952). 3,4,8 10,14 20 A Fow diagram indicating the results of the literature search and study selection procedure is presented in Figure 1; characteristics of included studies are presented in Table 1. The overall rate of complications was reported in all 12 studies. Complications included neuropathy, carpal tunnel syndrome, tendon rupture, tendon irritation, tenosynovitis, complex regional pain syndrome, screw loosening, infection, loss of reduction, healing problems and other complications. Using a random-effects model, there was no significant difference between the volar and dorsal approaches in the overall rate of complications (Figure 2). Substantial heterogeneity was observed (P < 0.001; I 2 72%), but sensitivity analyses indicated that Figure 1. Flow diagram indicating results of the literature search and study selection procedure for a metaanalysis comparing complication rates following volar or dorsal surgical fixation of distal radius fracture.
268 Journal of International Medical Research 41(2) Table 1. Principal characteristics of the studies included in a meta-analysis to compare the rate of complications following dorsal or volar fixation of distal radius fracture. Study Origin Implant type Total n Volar approach n Dorsal approach n Mean age years Sex M/F Follow-up months Study design Methodology score Zettl et al. 2001 14 Germany T-plate 92 49 43 58.3 31/61 36 c Case control 6 a Ruch and Papadonikolakis 2006 15 USA p-plate, d-plate, T-plate Rein et al. 2007 3 Germany T-plate, p-plate, locking plate 34 14 20 47.8 16/18 21.5 c Retrospective 6 a 29 15 14 54.7 17/12 22 c Retrospective 4 a Huang 2008 4 China T-plate 61 34 27 55.5 27/34 16 c RCT 7 b Jakubietz et al. 2008 16 Switzerland Angle-stable plate, 30 15 15 65.4 5/25 0.5, 1.5, 3, 12 d RCT 6 b p-plate Nalbantoğlu et al. 2008 17 Turkey T-plate, locking plate 63 23 40 46.5 35/28 12 102 e Retrospective 6 a Zettl et al. 2009 18 Germany LCP 120 60 60 66.0 30/90 1.5, 6, 12 d RCT 7 b Chappuis et al. 2011 8 Belgium DNP, DVR Õ 31 15 16 71.7 4/27 6 c RCT 8 b Chou et al. 2011 9 Taiwan Titanium locking plate 41 19 22 50.9 25/16 37 c Prospective 8 a Matschke et al. 2011 10 Germany LCP 305 266 39 53.9 105/200 6, 12, 24 d Prospective 7 a Yu et al. 2011 19 USA LoCon-T TM, LoCon-VLS TM, LCP Jakubietz et al. 2012 20 Germany Angle-stable plate, p-plate 104 47 57 53.0 NA 44 c Retrospective 6 a 42 22 20 NA NA 1.5, 3, 6, 12 d RCT 8 b M, male; F, female; RCT, randomized controlled trial; LCP, locking compression plate; DNP, dorsal nail plate; DVR Õ,DVR Õ anatomic plate (DePuy, Leeds, UK); LoCon-T TM, LoCon-T TM distal radial plate system (Wright Medical Technology, Arlington, TN, USA); LoCon-VLS TM, LoCon-VLS TM distal radial plate system (Wright Medical Technology), NA, not available. a Nonrandomized study methodology quality assessment scale (0 12). b RCT methodology quality assessment scale (0 11). c Mean value of follow-up. d Individual follow-up point. e Range of follow-up period.
Wei et al. 269 Figure 2. Meta-analysis of 12 studies that investigated the overall risk of complications following dorsal or volar fixation of distal radius fracture. Figure 3. Meta-analysis of 10 studies that investigated the risk of neuropathy following dorsal or volar fixation of distal radius fracture. the overall RR was not substantially influenced by any single study. Exclusion of Zettl et al. 14 resulted in decreased heterogeneity, however (P ¼ 0.03; I 2 49%). Subgroup analyses revealed that the volar approach was associated with a significantly increased risk of neuropathy (RR 2.19, 95% CI 1.27, 3.76; Figure 3) 3,4,8,9,14 16,18 20 and carpal tunnel syndrome (RR 4.56, 95% CI 1.02, 20.44; Figure 4) 4,8,10,18 compared with the dorsal approach. The risk of tendon irritation was significantly lower with the volar approach than the dorsal approach (RR 0.38, 95% CI 0.17, 0.86; Figure 5). 3,4,10,15,16,19,20 There were no significant between-approach differences in the risks of tendon rupture (Figure 6), 4,8,10,14,15,18 20 complex regional pain syndrome (Figure 7) 3,9,18,20 or screw loosening (Figure 8). 18,19,20 There was no evidence of publication bias (Figures 9 and 10).
270 Journal of International Medical Research 41(2) Figure 4. Meta-analysis of four studies that investigated the risk of carpal tunnel syndrome following dorsal or volar fixation of distal radius fracture. Figure 5. Meta-analysis of seven studies that investigated the risk of tendon irritation following dorsal or volar fixation of distal radius fracture. Figure 6. Meta-analysis of eight studies that investigated the risk of tendon rupture following dorsal or volar fixation of distal radius fracture.
Wei et al. 271 Figure 7. Meta-analysis of four studies that investigated the risk of complex regional pain syndrome following dorsal or volar fixation of distal radius fracture. 2 Figure 8. Meta-analysis of three studies that investigated the risk of screw loosening following dorsal or volar fixation of distal radius fracture. Figure 9. Begg s funnel plot for publication bias (with 95% pseudoconfidence limits) of 12 studies that investigated overall risk of complications following dorsal and volar fixation of distal radius fracture. RR, risk ratio; s.e., standard error.
272 Journal of International Medical Research 41(2) Figure 10. Begg s funnel plot for publication bias (with 95% pseudoconfidence limits) of studies that investigated risk of complications following dorsal and volar fixation of distal radius fracture. RR, risk ratio; s.e., standard error. Discussion There are several treatment options for distal radial fracture, with anatomical reduction and stable fixation a choice for displaced and unstable fractures. 20 The desired fixation method is the one that can not only maintain satisfactory reduction, but also allow early motion to avoid joint stiffness and disuse atrophy. 5 Open reduction and internal fixation can be performed via either the dorsal or the volar approach, the choice of which is often based on the direction of fragment displacement and the extent of metaphyseal comminution. 21 Both approaches have disadvantages: the volar approach requires substantial soft tissue dissection and the dorsal approach is associated with extensor tendon complications. 22,23 Dorsal plating of distal radius
Wei et al. 273 fractures has been shown to have good results, 21,24 and the functional outcome of volar plating has been reported. 3,15 The majority of clinical studies have reported only the outcome of dorsal or volar plating, not the complications associated with each of these procedures. 25,26 The different anatomical structures involved during volar and dorsal surgical approaches may have a role in the development of complications after plate application. A comparative study of the dorsal and volar approaches was unable to provide conclusive evidence to support a single, specific surgical technique. 3 Higher rates of volar collapse and late complications associated with dorsal plating were reported in a retrospective study of 34 patients with intraarticular fractures. 15 Contrary to this finding, improved outcomes were reported for 53 patients who received a T-plate via a dorsal approach. 1 The current meta-analysis revealed no statistically significant difference between dorsal or volar fixation in the overall risk of complications. Anatomical differences (particularly the proximity of tendons and nerves to the volar or dorsal plate) can contribute to different complication rates. A volar approach was shown to be associated with median nerve compression and carpal tunnel syndrome, with some patients requiring carpal tunnel release during or after surgery. 3 This is because the volar approach involves retraction of the median nerve, which may directly (or indirectly) lead to neuropathy and carpal tunnel syndrome. 3 Others have suggested a correlation between the volar approach and a heightened incidence of postoperative neuropathy, although it was not possible to determine whether the incidence of carpal tunnel syndrome and major neuropathies was due to pre-existing carpal tunnel syndrome or to the volar approach itself. 19 As the volar approach fixes the plate within anatomical structures (including the median nerve), it is likely that this may contribute to increased incidence of carpal tunnel syndrome and neuropathic complications, compared with the dorsal approach. The dorsal approach is associated with a high rate of local irritation or tenosynovitis of the extensor tendon, 27,28 which is consistent with the findings of the current analysis where the risk of tendon irritation was significantly lower with the volar than the dorsal approach. This may be explained by the anatomy: the volar diaphyseal cortex is protected by muscle but the dorsal cortex is not, leaving the extensor tendons at risk from any screw protrusion. In conclusion, the present meta-analysis indicates that dorsal fixation offers a lower risk of neuropathy and carpal tunnel syndrome than the volar approach, but a higher risk of tendon irritation. In terms of other complications, patients with distal radius fractures can expect similar outcomes after volar or dorsal surgery. Declaration of conflicting interest The authors declare that there are no conflicts of interest. Funding This work was supported by the Young Teacher s boosting project of the Fundamental Research Funds for the Central Universities in Central South University, China (2012QNZT095). References 1. Simic PM and Weiland AJ. Fractures of the distal aspect of the radius: changes in treatment over the past two decades. Instr Course Lect 2003; 52: 185 195. 2. Gehrmann SV, Windolf J and Kaufmann RA. Distal radius fracture management in elderly patients: a literature review. J Hand Surg Am 2008; 33: 421 429. 3. Rein S, Schikore H, Schneiders W, et al. Results of dorsal or volar plate fixation of AO type C3 distal radius fractures: a retrospective study. J Hand Surg Am 2007; 32: 954 961.
274 Journal of International Medical Research 41(2) 4. Huang JJ. Comparison between volar and dorsal plate positions in the treatment of unstable fracture of distal radius. Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi 2008; 22: 948 951 [in Chinese, English abstract]. 5. Leung F, Zhu L, Ho H, et al. Palmar plate fixation of AO type C2 fracture of distal radius using a locking compression plate a biomechanical study in a cadaveric model. J Hand Surg Br 2003; 28: 263 266. 6. Blythe M, Stoffel K, Jarrett P, et al. Volar versus dorsal locking plates with and without radial styloid locking plates for the fixation of dorsally comminuted distal radius fractures: a biomechanical study in cadavers. J Hand Surg Am 2006; 31: 1587 1593. 7. Rozental TD and Blazar PE. Functional outcome and complications after volar plating for dorsally displaced, unstable fractures of the distal radius. J Hand Surg Am 2006; 31: 359 365. 8. Chappuis J, Bouté P and Putz P. Dorsally displaced extra-articular distal radius fractures fixation: dorsal IM nailing versus volar plating. A randomized controlled trial. Orthop Traumatol Surg Res 2011; 97: 471 478. 9. Chou YC, Chen AC, Chen CY, et al. Dorsal and volar 2.4-mm titanium locking plate fixation for AO type C3 dorsally comminuted distal radius fractures. J Hand Surg Am 2011; 36: 974 981. 10. Matschke S, Wentzensen A, Ring D, et al. Comparison of angle stable plate fixation approaches for distal radius fractures. Injury 2011; 42: 385 392. 11. Van Tulder M, Furlan A, Bombardier C, et al. Updated method guidelines for systematic reviews in the Cochrane Collaboration Back Review Group. Spine (Phila Pa 1976) 2003; 28: 1290 1299. 12. Wells GA, Shea B, O Connell D, et al. The Newcastle-Ottawa Scale (NOS) for assessing the quality of nonrandomised studies in metaanalyses, http://www.ohri.ca/programs/clinical_epidemiology/oxford.asp (2011, accessed 23 January 2013). 13. Begg CB and Mazumdar M. Operating characteristics of a rank correlation test for publication bias. Biometrics 1994; 50: 1088 1101. 14. Zettl RP, Ruchholtz S, Taeger G, et al. Postoperative morbidity in surgically treated extension fractures of the distal radius. A comparative study of dorsal and volar approach. Unfallchirurg 2001; 104: 710 715 [in German, English abstract]. 15. Ruch DS and Papadonikolakis A. Volar versus dorsal plating in the management of intra-articular distal radius fractures. J Hand Surg Am 2006; 31: 9 16. 16. Jakubietz RG, Gruenert JG, Kloss DF, et al. A randomised clinical study comparing palmar and dorsal fixed-angle plates for the internal fixation of AO C-type fractures of the distal radius in the elderly. J Hand Surg Eur Vol 2008; 33: 600 604. 17. Nalbantog lu U, Gereli A, Uc ar Y, et al. Comparison between fixation with dorsal T plate and palmar locking plate in the treatment of unstable displaced distal radius fractures. Acta Orthop Traumatol Turc 2008; 42: 365 372 [in Turkish, English abstract]. 18. Zettl RP, Clauberg E, Nast-Kolb D, et al. Volar locking compression plating versus dorsal plating for fractures of the distal radius: a prospective, randomized study. Unfallchirurg 2009; 112: 712 718 [in German, English abstract]. 19. Yu YR, Makhni MC, Tabrizi S, et al. Complications of low-profile dorsal versus volar locking plates in the distal radius: a comparative study. J Hand Surg Am 2011; 36: 1135 1141. 20. Jakubietz MG, Gruenert JG and Jakubietz RG. Palmar and dorsal fixed-angle plates in AO C-type fractures of the distal radius: is there an advantage of palmar plates in the long term? J Orthop Surg Res 2012; 7: 8. 21. Osada D, Tamai K, Iwamoto A, et al. Dorsal plating for comminuted intraarticular fractures of the distal end of the radius. Hand Surg 2004; 9: 181 190. 22. Sen MK, Strauss N and Harvey EJ. Minimally invasive plate osteosynthesis of distal radius fractures using a pronator sparing approach. Tech Hand Up Extrem Surg 2008; 12: 2 6. 23. Ozer K and Toker S. Dorsal tangential view of the wrist to detect screw penetration to the dorsal cortex of the distal radius after volar
Wei et al. 275 fixed-angle plating. Hand (NY) 2011; 6: 190 193. 24. Tavakolian JD and Jupiter JB. Dorsal plating for distal radius fractures. Hand Clin 2005; 21: 341 346. 25. Mignemi ME, Byram IR, Wolfe CC, et al. Radiographic outcomes of volar locked plating for distal radius fractures. J Hand Surg Am 2013; 38: 40 48. 26. Tyllianakis ME, Panagopoulos AM and Saridis A. Long-term results of dorsally displaced distal radius fractures treated with the pi-plate: is hardware removal necessary? Orthopedics 2011; 34: e282 286. 27. Ring D, Jupiter JB, Brennwald J, et al. Prospective multicenter trial of a plate for dorsal fixation of distal radius fractures. J Hand Surg Am 1997; 22: 777 784. 28. Rozental TD, Beredjiklian PK and Bozentka DJ. Functional outcome and complications following two types of dorsal plating for unstable fractures of the distal part of the radius. J Bone Joint Surg Am 2003; 85: 1956 1960.