Zimmer Trabecular Metal Dental Implant

Similar documents
Tapered Screw-Vent Implant System

Trabecular Metal Primary Hip Prosthesis

scientific compendium

Zimmer Segmental System

The simple solution. One complete system. Tapered Screw-Vent Implant System Prosthetic Overview

The simple solution. One complete system. Tapered Screw-Vent Implant System Prosthetic Overview

Trabecular Metal Acetabular Restrictor and Augment

Trabecular Metal Acetabular Restrictor and Augment

scientific compendium Zimmer Trabecular Metal Dental Implant trabecular metal material: Designed to Enhance Secondary Stability Through Bone Ingrowth.

TRABECULAR METAL ACETABULAR RESTRICTOR AND AUGMENT. Surgical Technique

Trabecular Metal Acetabular Revision System Buttress and Shim Augments Surgical Technique

Trabecular Metal Technology The Best Thing Next to Bone

1Acetabular Reaming. 2Shell Sizing and Positioning. Trial Range of Motion. Trabecular Metal Natural Cup System

HISTORY. PERFORMANCE. SUCCESS.

Rock-solid fit. A connection you can depend on. Internal Hex with Friction-Fit

Trabecular Metal Natural Cup System

Case Study. Case # 1 Author: Dr. Suheil Boutros (USA) 2013 Zimmer Dental, Inc. All rights reserved. 6557, Rev. 03/13.

Tapered Screw-Vent Implant. A Legacy Of Performance

Regenerex Porous Titanium Construct. Knees Hips Extremities Cement and Accessories PMI Trauma Technology

Arcos Modular Femoral Revision System

PINNACLE REVISION CUP SYSTEM

Enhancing stability and increasing range of motion. Metasul LDH Large Diameter Head

Zfx GenTek Genuine Restorations and Open Digital Workflows. Easy, fast, genuine.

Trabecular Metal Dental Implant

Featuring. Technology. Product Rationale

Tantalum (Ta)-based, porous engineered implants

THE PERSONALIZED KNEE

Understanding Hip Implant Options

Cement Polished Tapered Stems of 12/14 Taper. 96 mm 98 mm 104 mm 110 mm 116 mm 122 mm 128 mm. Ceramic Femoral Head. Outer Diameter

DEVELOPED BY SURGEONS

Surgery All at Once : Socket preservation and immediate placement of an implant in an infected site in the anterior region a Case Report

Porous metal augments

More than bone regeneration. A total solution.

NobelProcera Implant Bar Overdenture complete range of fixed and removable solutions.

Optimum implant geometry

JD Implant: 10 reasons for the best choice

Optimum implant geometry

Hedrocel trabecular metal monoblock acetabular cups : mid-term results

Eztetic 3.1 mmd Implant System. Product Catalog And Surgical Technique

RECLAIM REVISION HIP SYSTEM

Dr. John Masonis Charlotte, NC OrthoCarolina. Dr. James Waddell Toronto, Ontario University of Toronto, St. Michael s Hospital

S i m p l i c I t y, c o m f o r t, a e s t h e t i c s. axiom. The new dimension

Restoring Quality Of Life. Zimmer Biomet Dental Implants. A Better Treatment Option

G7 ACETABULAR SYSTEM. beautifully. efficient.

contents the smarter case approach reasons to choose simplyintegrated 5 system overview 6 ordering 7 mount-free implants 8-9

Longevity Offset and Oblique Liners. Surgical Technique

OSSIS is an ISO accredited company.

More than pure esthetics. The natural and strong solution.

introduction to BioHorizons prosthetics

LOCATOR F-Tx FIXED ATTACHMENT SYSTEM

Approach Patients with CONFIDENCE

PLR. Proximal Loading Revision Hip System

OSSIS is an ISO accredited company.

Case report: Pain L THR [ post THR 2 years; with history of trivial fall] Your Diagnosis?

Systematic Review of Clinical Outcome using Titanium Fiber Mesh Porous Ingrowth Surfaces

comprehensive Design Rationale shoulder system Knees Hips Extremities Cement and Accessories PMI TEchnology

The Multi-unit Abutments of the CE-Series are indicated for Nobel Biocare / NobelReplace Tapered. The current implant diameters have to be attended.

NARROW DIAMETER implant

High Crown to Implant Ratio as Stress Factor in Short Implants Therapy

More than an implant. A sense of trust. Straumann Dental Implant System

More than an implant. A sense of trust.

Platform switching for marginal bone preservation around dental implants: a systematic review and meta-analysis.

Pressure Necrosis And Osseointegration: An Editorial White Paper*

Early results of Trabecular Metal augment for acetabular reconstruction in revision hip arthroplasty

ACETABULAR CUP SURGICAL TECHNIQUE

SURGICAL TECHNIQUE. Protrusio Cage A COMPREHENSIVE ACETABULAR REVISION SYSTEM

Plasmapore XP. Stability that Starts at the Surface

Allofit /Allofit -S Alloclassic Acetabular Cup System

simply simply digital simply crown & bridge simply removable simply fixed simply à la carte

Enhancing implant stability with osseodensification a case report with 2-year follow-up

Reaching new heights. Comprehensive. Efficient. Simple.

S h o u l d e r Solutions by Tornier C o n v e r T i b l e S h o u l d e r S y S T e m

Description: Prosthetic Components for dental restoration under CE-Series, CL- Series, CN-Series, CH-Series, CF-Series, CR-Series, CS-Series.

Over 20 Years of Proven Clinical Success. Zimmer Natural-Knee II System

INTERNAL HEX ( ps) PLATFORM SHIFT PRESERVATION OF BONE NEVER LOOKED BETTER

Puros Cancellous Particulate Allograft & Puros Block Allograft

Four implants...choice of Connection. Each implant comes with Hex or Conical Connection.

Osseointegrated dental implant treatment generally

Zimmer TM. Continuum Acetabular System. Bringing together proven technologies.

OD Secure chairside pick-up using existing denture

NobelReplace Conical Connection Product overview

This article is the third in a series for Oral Health

Straumann. This is a real breakthrough. Roxolid implant, make the restoration, then go home and sleep well at night.

Principles of acetabular fixation in primary and revision hip arthroplasty Piotr Wojciechowski, Damian Kusz, Anna WAGNER

Dental Implant Treatment Planning and Restorative Considerations

ZMR Crossover Instruments. Abbreviated Surgical Technique

ZMR CROSSOVER INSTRUMENTS AND SURGICAL TECHNIQUE. Surgical Technique for Revision Hip Arthroplasty

» For multi-unit restorations -

R3think your options. For US distribution only.

Bone Preservation Stem

HOSPITAL "A" (2007) ORTHOPEDIC JOINT IMPLANT COMPONENT MATRIX

Where technology meets dentistry INNOVATION. at a GLANCE

RM Philosophy Innovation based on clinical evidence.

LOCATOR R-Tx REMOVABLE ATTACHMENT SYSTEM

G03: Complications 12/7/2013 8:00AM 4:30PM

Consensus Statements and Recommended Clinical Procedures Regarding Loading Protocols

REGENERATIONTIME. A Case Report by. Ridge Augmentation and Delayed Implant Placement on an Upper Lateral Incisor

Laboratory Solutions. Optimization By Design

Transcription:

Zimmer Trabecular Metal Dental Implant TRABECULAR METAL MATERIAL: Designed to Enhance Secondary Stability Through Bone Ingrowth. Artistic Rendering

osseoincorporation TRABECULAR METAL MATERIAL Designed to Enhance Secondary Stability Through Bone Ingrowth The Zimmer Trabecular Metal Dental Implant combines the popular features of the Tapered Screw-Vent Implant with the unique properties of Trabecular Metal Material. Due to the interconnected porosity it is designed to enhance secondary stability through osseoincorporation.

Osseoincorporation Ongrowth + Ingrowth: Zimmer Dental s MTX Microtextured Surface has been documented to achieve high levels of bone-toimplant contact, or ongrowth. 1,2 The Trabecular Metal Dental Implant features an osteoconductive mid-section designed for bone ingrowth as well as ongrowth in a process new to implant dentistry osseoincorporation. 3-5 Osseoincorporation refers to the healing potential of bone onto an implant surface and into an implant structure. The interconnected porosity of Trabecular Metal Material is designed to enhance secondary stability through a high volume of ingrowth. 5,9,21 Studies of the Trabecular Metal Dental Implant are currently underway and additional studies are planned to document the process of osseoincorporation by measuring the volume and rate of bone ingrowth. Trabecular Metal Material Osseoincorporation Trabecular bone The process of ingrowth Artistic Rendering The Best Thing Next to Bone Trabecular Metal Technology is a three-dimensional material, not an implant surface or coating. Its structure is similar to cancellous bone. 4,6,10 Trabecular Metal Material has up to 80% fully interconnected porosity designed for bone ingrowth. 3-5,7,10,11 Trabecular Metal Material at 200x Zimmer has utilized Trabecular Metal Material The Best Thing Next to Bone for over a decade in implantable orthopaedic devices. Now Zimmer brings this unique technology to implant dentistry with the Trabecular Metal Dental Implant.

The Evolution of a Trusted Design Zimmer Dental proudly introduces the Trabecular Metal Dental Implant, a premium addition to the Tapered Screw-Vent Implant System the implant family trusted by clinicians for over a decade. Sharing some of the most popular Tapered Screw-Vent Implant design features, the new Trabecular Metal Dental Implant offers clinicians additional treatment planning options. Tapered Screw-Vent Implant Trabecular Metal Material Trabecular Metal Implant Compatibility for versatility The Trabecular Metal Dental Implant is placed with the Zimmer Instrument Kit System and restored using the extensive selection of Tapered Screw-Vent prosthetic components. This compatibility allows for convenient integration of the Trabecular Metal Dental Implant into treatment plans without requiring additional surgical purchases or new restorative procedures.

Trabecular Metal Den The Best Thing Next to Bone. 5 Tapered Implant Body Designed for primary stability, the tapered titanium alloy body provides the strength of traditional dental implants. 15-18 4 MTX Surface for ongrowth The MTX Microtextured Surface has been documented to achieve high levels of bone-to-implant contact, or ongrowth. 1,2

tal Implant 1 Trabecular Metal MATERIAL for bone ingrowth The implant s Trabecular Metal Material mid-section has been designed for bone ingrowth and ongrowth. 3-5 Zimmer Dental continues to gather data to document the volume and rate of osseoincorporation and its effects on secondary stability. 2 crestal options for bone-level maintenance The coronal microgrooves are designed to preserve crestal bone. 14 Two coronal surface configurations are available: 0.5mm Machined Titanium (Model TMM, shown above). MTX Microtexturing to the top (Model TMT, shown to the left). The Virtual Cold Weld Abutment Implant 3 Platform Plus Technology The proprietary internal hex connection, utilized with Zimmer Dental s friction-fit abutments, has been documented to shield crestal bone from concentrated occlusal forces, in an in vitro FEA. 12,13* * Results are not necessarily predictive of human clinical results.

Clinical Cases Human clinical studies of the Trabecular Metal Dental Implant began in 2010, and data collection will continue in the coming years. Additional studies to document osseoincorporation in humans and animals are in progress. In 2011, the availability of the Trabecular Metal Dental Implant was extended to clinicians and their patients in Europe, and in 2012, the United States and other countries. In a preliminary study of Trabecular Metal Dental Implants in canine mandibular models, evidence of ingrowth by maturing bone was documented as early as two weeks after implantation. 19,20 Further data is being collected to document the rate of ingrowth and its effects on secondary stability in human dental applications. Trabecular Metal Dental Implant placed in the maxilla and immediately loaded. Image 2012 Dr. Markus Schlee, Forchheim, Germany. Final restoration at 14 days* Trabecular Metal Dental Implant placed in the mandible. Images 2012 Dr. Markus Schlee, Forchheim, Germany. One-year result *Immediate loading is indicated when there is good primary stability and an appropriate occlusal load.

References 1. Trisi P, Marcato C, Todisco M. Bone-to-implant apposition with machined and MTX microtextured implant surfaces in human sinus grafts. Int J Periodontics Restorative Dent. 2003;23(5):427-437. 2. Todisco M, Trisi P. Histomorphometric evaluation of six dental implant surfaces after early loading in augmented human sinuses. J Oral Implantol. 2006;32(4):153-166. 3. Wigfield C, Robertson J, Gill S, Nelson R. Clinical experience with porous tantalum cervical interbody implants in a prospective randomized controlled trial. Br J Neurosurg. 2003;17(5):418-425. 4. Unger AS, Lewis RJ, Gruen T. Evaluation of a porous tantalum uncemented acetabular cup in revision total hip arthroplasty. Clinical and radiological results of 60 hips. J Arthroplasty. 2005;20(8):1002-1009. 5. Bobyn JD, Stackpool GJ, Hacking SA, Tanzer M, Krygier JJ. Characteristics of bone ingrowth and interface mechanics of a new porous tantalum biomaterial.j Bone Joint Surg Br. 1999; 81:907-914. 6. Cohen R. A porous tantalum trabecular metal: basic science. Am J Orthop. 2002;31(4):216-217. 7. Tsao AK, Roberson JR, Christie MJ, Dore DD, Heck DA, Robertson DD, Poggie RA. Biomechanical and clinical evaluations of a porous tantalum implant for the treatment of early-stage osteonecrosis. J Bone Joint Surg. 2005;87-A(Suppl 2):22-27. 8. Williams DF. Titanium as a metal for implantation. Part 1: Physical properties. J Med Eng Tech. 1977;7:195-198,202. For more information about the Zimmer Trabecular Metal Dental Implant, visit trabecularmetal.zimmerdental.com. 1900 Aston Avenue Carlsbad, CA 92008-7308 USA In the U.S. 1 (800) 854-7019 To fax an order 1 (888) 225-2483 Outside the U.S. +1 (760) 929-4300 Australia +61 (0)2 9950 5434 or 1 (800) 241 916 Canada + 1 (905) 567-2073 or 1 (800) 265-0968 Chile +562 231 5185 9. Bobyn JD, Hacking SA, Chan SP, et al. Characterization of a new porous tantalum biomaterial for reconstructive orthopaedics. Scientific Exhibit, Proc of AAOS, Anaheim, CA, 1999. 10. Bobyn JD. UHMWPE: the good, bad, & ugly. Fixation and bearing surfaces for the next millennium. Orthop. 1999;22(9):810-812. 11. Nasser S, Poggie RA. Revision and salvage patellar arthroplasty using a porous tantalum implant. J Arthroplasty. 2004;19(5):562-572. 12. Mihalko WM, May TC, Kay JF, Krause WP. Finite element analysis of interface geometry effects on the crestal bone surrounding a dental implant. Implant Dent. 1992;1:212-217. 13. Chun HJ, Shin HS, Han CH, Lee SH. Influence of implant abutment type on stress distribution in bone under various loading conditions using finite element analysis. Int J Oral Maxillofac Implants. 2006;21:105-202. 14. Shin SY, Han DH. Influence of a microgrooved collar design on soft and hard tissue healing of immediate implantation in fresh extraction sites in dogs. Clin Oral Implants Res. 2010;21:804-814. 15. Data on file., 16. Data on file., 17. Data on file., 18. Data on file., 19. Data on file., 20. Data on file. 21. Data on file. China +86 21 22115147 France +33 (0)1 45 12 35 35 Germany +49 (0)761 1 56 47 0 Israel +972 (0)3 6124242 Italy +39 0438 37681 Spain +34 93 846 05 43 2012 Zimmer Dental Inc. All rights reserved. 5986, Rev. 12/12. Please note that not all products are registered or available in every country/region. Please check with a Zimmer Dental representative for availability and additional information. To receive our enews visit us at http://www.zimmerdental.com/news_enewslettersignup.aspx www.zimmerdental.com Information on the products and procedures contained in this document is of a general nature and does not represent and does not constitute medical advice or recommendations. Because this information does not purport to constitute any diagnostic or therapeutic statement with regard to any individual medical case, each patient must be examined and advised individually, and this document does not replace the need for such examination and/or advice in whole or in part. Please refer to the package inserts for important product information, including, but not limited to, contraindications, warnings, precautions, and adverse effects.