Oxygen and Oxygen Equipment

Similar documents
Oxygen and Oxygen Equipment

Oxygen and Oxygen Equipment

Clinical Policy: Oxygen Therapy in the Home Reference Number: CP.MP.485

LCD for Oxygen and Oxygen Equipment (L11457)

MEDICAL POLICY SUBJECT: HOME AND COMMUNITY OXYGEN THERAPY

Oxygen Therapy Coverage Guidelines for Non-Medicare Advantage Members

MEDICAL POLICY SUBJECT: HOME AND COMMUNITY OXYGEN THERAPY

CERT Oxygen Errors: The DME CERT Outreach and Education Task Force Responds

LCD for Oxygen and Oxygen Equipment (L27221)

Policy Specific Section: October 1, 2010 January 21, 2013

Positive Airway Pressure and Oral Devices for the Treatment of Obstructive Sleep Apnea

CLINICAL MEDICAL POLICY

CLINICAL MEDICAL POLICY

Airway Clearance Devices

Positive Airway Pressure and Oral Devices for the Treatment of Obstructive Sleep Apnea

Positive Airway Pressure and Oral Devices for the Treatment of Obstructive Sleep Apnea

Medics Home Health Services 1075 South Main St. Ste. 450 Madison, GA P F

RESPIRATORY EQUIPMENT AND SUPPLIES CSHCN SERVICES PROGRAM PROVIDER MANUAL

Blue Cross and Blue Shield of Illinois Provider Manual. Durable Medical Equipment (DME) Section

Medicare CPAP/BIPAP Coverage Criteria

Respiratory Equipment and Supplies

CERT PAP Errors: The DME CERT Outreach and Education Task Force Responds

MEDICARE Quick Reference Guide. Reimbursement Guidelines for Referral Sources

Polysomnography and Sleep Studies

Medicare C/D Medical Coverage Policy. Respiratory Assist Devices for Obstructive Sleep Apnea and Breathing Related Sleep Disorders

Respiratory Assist Device E0470:

RESPIRATORY ASSIST DEVICE E0470

OXYGEN USE IN PHYSICAL THERAPY PRACTICE. Rebecca H. Crouch, PT,DPT,MS,CCS,FAACVPR

DECISION AND ORDER. After due notice, a telephone hearing was held on. , Medical Director, also testified as a witness for the MHP.

Home Pulse Oximetry for Infants and Children

TOPIC: Continuing Coverage of CPAP Machines and Supplies for the Treatment of Obstructive Sleep Apnea

Physical Therapy. Physical Therapy Payment Policy Page 1

CPAP. The CPAP will be covered

Cues for Coding & Coverage

Helpful hints for filing

Itamar Medical 2016 Reimbursement Coding Guide

RESPIRATORY ASSIST DEVICE E0471

Occupational Therapy. Occupational Therapy Payment Policy Page 1

RESPIRATORY ASSIST DEVICE E0471

BTS Guideline for Home Oxygen use in adults Appendix 9 (online only) Key Questions - PICO 10 December 2012

Polysomnography - Sleep Studies

Emergency Medicine High Velocity Nasal Insufflation (Hi-VNI) VAPOTHERM POCKET GUIDE

Enclosed on Page 5 is an authorization form to release your health information.

(To be filled by the treating physician)

OMAP updated the Durable Medical Equipment, Prosthetics, Orthotics and Supplies (DMEPOS) program Rulebook as follows:

Positive Airway Pressure (PAP) Devices Physician Frequently Asked Questions December 2008

Medicare Part C Medical Coverage Policy

10/17/2016 OXYGEN DELIVERY: INDICATIONS AND USE OF EQUIPMENT COURSE OBJECTIVES COMMON CAUSES OF RESPIRATORY FAILURE

Nonsurgical Interventional Treatments for Spinal Pain Management

OSA and COPD: What happens when the two OVERLAP?

Spinal and Trigger Point Injections

Medical Affairs Policy

POLICIES AND PROCEDURE MANUAL

Women s Preventive Health Guidelines

Improving Care & Outcomes

Premier Health Plan considers Negative Pressure Wound Therapy (NPWT) in the home setting medically necessary for the following indications:

Nutritional Counseling

Clinical Features of Patients on Home Oxygen Therapy Due to Chronic Respiratory Failure at One University Hospital

Applied Behavior Analysis for Autism Spectrum Disorders

Speech Therapy. 4. Therapy is used to achieve significant, functional improvement through specific diagnosisrelated

New Government O2 Criteria and Expert Panel. Jennifer Despain, RPSGT, RST, AS

Jurisdiction B, C and D Combined Council Questions Sorted by A-Team May, 2015

Ron Hosp, MS-HSA, RRT Regional Respiratory Specialist. This program has been approved for 1 hour of continuing education credit.

Oxygenation. Chapter 45. Re'eda Almashagba 1

LCD for Positive Airway Pressure (PAP) Devices for the Treatment of Obstructive Sleep Apnea (L171)

Respiratory Care Equipment

CPAP. Respiratory and General DME Mission Do you Accept? /14/2016

Tissue Hypoxia and Oxygen Therapy

Name of Policy: Noninvasive Positive Pressure Ventilation

Indications for Respiratory Assistance. Sheba Medical Center, ICU Department Nick D Ardenne St George s University of London Tel Hashomer

About VirtuOx. Was marketed exclusively by Phillips Healthcare division, Respironics for 3 years

Treatment of Obstructive Sleep Apnea (OSA)

Respiratory Equipment and Supplies

Up to 50% of continuous flow oxygen therapy patients experience clinically significant nocturnal desaturation. 1

Identification and Treatment of the Patient with Sleep Related Hypoventilation

Breast Reconstruction Surgery

Respiratory Conditions and the Commercial Driver

Negative Pressure Wound Therapy (NPWT)

Evaluation of the Effect of Prehospital Application of Continuous Positive Airway Pressure Therapy in Acute Respiratory Distress

Oxygen Use in Palliative Care Guideline and Flowchart

HOME OXYGEN THERAPY (AT REST) Ht: Wt: Home Oxygen with Portability X LPM Continuous Pulse Ox XX% on Room Rest Evaluate for conserving device*

BTS Guidelines for Home Oxygen in Children

5/3/2012 PRESENTATION GOALS RESPIRATORY THERAPISTS ROLE IN END OF LIFE CARE FOR THE PULMONARY PATIENT

Chronic Obstructive Pulmonary Disease (COPD) Copyright 2014 by Mosby, an imprint of Elsevier Inc.

COPD is a syndrome of chronic limitation in expiratory airflow encompassing emphysema or chronic bronchitis.

NON INVASIVE LIFE SAVERS. Non Invasive Ventilation (NIV)

DERBYSHIRE JOINT AREA PRESCRIBING COMMITTEE (JAPC) OXYGEN GUIDELINE

SmartMonitor Helpful for Filing

Corporate Medical Policy

Durable Medical Equipment, Prosthetics, Orthotics and Supplies (DMEPOS) Rulebook

County of Santa Clara Emergency Medical Services System

WRHA Surgery Program. Obstructive Sleep Apnea (OSA)

POLICY All patients will be assessed for risk factors associated with OSA prior to any surgical procedures.

Lung-Volume Reduction Surgery ARCHIVED

Extracorporeal Membrane Oxygenation (ECMO)

Corporate Medical Policy

Respiratory Equipment and Supplies

Transcription:

Oxygen and Oxygen Equipment I. Policy University Health Alliance (UHA) will reimburse for home oxygen and oxygen equipment when it is determined to be medically necessary and when it meets the medical criteria guidelines (subject to limitations and exclusions) indicated below. II. Criteria/Guidelines A. Home oxygen and oxygen equipment are covered (subject to Limitations/Exclusions and Administrative Guidelines) for patients age 13 years and older when the following criteria are met: 1. The treating physician has determined that the patient has severe chronic respiratory disease with hypoxemia that is expected to improve with long-term oxygen therapy, Such diagnoses include the following: a. Chronic obstructive pulmonary disease (COPD) b. Diffuse interstitial lung disease c. Cystic fibrosis d. Bronchiectasis e. Widespread pulmonary neoplasm f. Pulmonary hypertension g. Obstructive sleep apnea (OSA) that is being treated with positive airway pressure 2. The treating physician has determined that the patient has an acute illness with hypoxemia resulting in the need for short-term oxygen therapy. Such conditions include the following:: a. Pneumonia b. Exacerbation of underlying chronic lung disease c. Congestive heart failure 3. Alternative treatment measures have been tried and deemed clinically ineffective. 4. Hypoxemia is evidenced by any of the following qualifying blood gas studies, i.e., arterial blood gas (ABG) test or oximetry test: a. Arterial PaO2 less than or equal to 55 millimeters of mercury (mm Hg), or arterial oxygen saturation of less than or equal to 88 percent at rest; or b. Arterial PaO2 less than or equal to 55 mmhg, or arterial oxygen saturation less than or equal to 88 percent for at least five minutes (does not need to be continuous) taken during sleep. c. A decrease in arterial PaO2 of more than 10 mm Hg, or a decrease in arterial oxygen saturation of more than 5 percent for at least five minutes (does not need to be continuous) taken during sleep, associated with signs reasonably attributed to hypoxemia including, but not limited to, cor pulmonale, documented pulmonary hypertension, erythrocytosis (polycythemia); or Page 1

d. Arterial PaO2 less than or equal to 55 mm Hg, or arterial oxygen saturation less than or equal to 88 percent during AND when it is documented that oxygen improves the hypoxemia demonstrated during exercise with the patient breathing room air; or e. Arterial PaO2 of 56 to 59 mm Hg or an arterial oxygen saturation of 89 percent at rest while awake, during sleep for at least five minutes, or during exercise as described above, and any of the following: i. Recurring right heart failure due to cor pulmonale Pulmonary hypertension determined by measurement of pulmonary artery pressure or echocardiogram i Erythrocytosis with a hematocrit greater than 56 percent 5. Qualifying blood gas test meets the following criteria: a. For chronic conditions resulting in a need for long-term oxygen therapy, the test is performed while the patient is receiving optimal medical management and is in a chronic stable state, i.e., not during a period of acute illness or an exacerbation of their underlying disease. The test must be the most recent test performed within 30 days of initiation of therapy. b. For acute illness resulting in a need for short-term oxygen therapy, the test is performed in an emergency department or within two days of discharge from an inpatient hospital stay. The reported test must be the one obtained closest to the hospital discharge date. c. The test is performed on room air unless medically contraindicated. If done with the patient on oxygen, the qualifying arterial blood gas or oxygen saturation values must still be met. B. Home oxygen and oxygen equipment are covered (subject to Limitations/Exclusions and Administrative Guidelines) for patients below the age of 13 (i.e. before the patient's 13th birthday) when the following criteria are met: 1. The patient has a chronic condition that is expected to improve with oxygen therapy; and 2. Oxygen saturation rate is persistently or episodically 92 percent or lower measured in a chronic, stable state (as defined in II.5.a.), or 3. Oxygen saturation rate is 95 percent or lower and the patient has a diagnosis of pulmonary hypertension demonstrated by EKG, echocardiogram and/or cardiac catheterization. C. Oxygen and oxygen equipment capable of delivering 100% oxygen, i.e., at least seven liters per minute (LPM) via a non-rebreather mask, are covered for the treatment of cluster headache. D. Continuation of therapy for the indications noted above is covered when documentation supports that the patient continues to require oxygen when in a chronic stable state and is compliant with therapy. E. A portable oxygen system is covered if the patient is mobile within the home and the qualifying blood gas study was performed while at rest (awake) or during exercise. F. Liter flow greater than four LPM is covered only if a blood gas study performed while the patient is on four LPM and meets criteria II.A.4 above. III. Limitations/Exclusions A. Home oxygen is not covered for the following conditions: 1. Angina pectoris in the absence of hypoxemia 2. Dyspnea without evidence of hypoxemia Page 2

3. Severe peripheral vascular disease resulting in clinically evident oxygen desaturation in one or more extremities, but in the absence of systemic hypoxemia 4. Terminal illnesses that do not affect the respiratory system 5. Airway diseases including asthma, bronchiolitis, and croup. B. The use of home oxygen therapy as the sole treatment of OSA, i.e., in the absence of positive airway pressure, is not covered as it is not the most appropriate delivery of service. Patients with OSA and oxygen desaturation that is not related to their OSA are candidates for home oxygen therapy. C. Oxygen for use with a PAP device for the treatment of OSA is covered only when oximetry demonstrates an oxygen saturation less than or equal to 88 percent for at least 5 minutes (which need not be continuous) on optimal PAP settings which is defined as the settings that result in a decrease of AHI/RDI to less than 10. D. When both ABG and oximetry tests have been performed on the same day under the same conditions, i.e., at rest/awake, during exercise, or during sleep, the ABG result will be used to determine if coverage criteria are met. If an ABG result at rest/awake does not meet criteria, but an exercise or sleep oximetry test result on the same day meets criteria, the oximetry test will determine coverage. E. When oxygen is covered based on an oxygen study obtained during exercise, there must be documentation of three oxygen studies which must be performed within the same testing session: 1. testing at rest without oxygen 2. testing during exercise without oxygen 3. testing during exercise with oxygen (to demonstrate the improvement of the hypoxemia) F. The qualifying blood gas study may not be performed or paid for by the supplier. G. Portable oxygen is not covered if the only qualifying blood gas study was done during sleep. H. It is the patient's responsibility to arrange for oxygen when traveling outside of their supplier's usual service area. Payment for oxygen will be made to only one supplier during any one rental month. I. Emergency or stand-by oxygen systems for patients who are not regularly using oxygen (with the exception of cluster headache as in criterion II.B.) and back-up oxygen systems are not covered since they are precautionary and not therapeutic in nature. J. If oxygen equipment reaches its five year reasonable lifetime, but is in good working order and meets the patient s medical needs, replacement equipment will not be covered. K. Oxygen equipment is only covered as a rental item. L. Payment for accessories (cannula, tubing, etc.) is included in the rental allowance. M. NOTE: This UHA payment policy is a guide to coverage, the need for prior authorization and other administrative directives. It is not meant to provide instruction in the practice of medicine and it should not deter a provider from expressing his/her judgment. Even though this payment policy may indicate that a particular service or supply is considered covered, specific provider contract terms and/or member s individual benefit plans may apply, and this policy is not a guarantee of payment UHA reserves the right to apply this payment policy to all UHA companies and subsidiaries. UHA understands that opinions about and approaches to clinical problems may vary. Questions concerning medical necessity (see Hawaii Revised Statutes 432E-1.4) are welcome. A provider may request that UHA reconsider the application of the medical necessity criteria in light of any supporting documentation. IV. Administrative Guidelines Page 3

A. For patients below the age of 13, prior authorization is not required for initial or continued therapy. B. For patients age 13 and older: 1. Prior Authorization is not required for the initial three months of coverage. Documentation from the patient s medical record supporting that the patient has severe respiratory disease and that alternative treatment measures have been tried and determined to be clinically ineffective and the qualifying blood gas study result must be maintained in the patient s medical record. 2. Prior Authorization for continuation of oxygen for up to an additional nine months is required after the initial three month period. Documentation that must be submitted with the prior authorization request includes: a. Oxygen provided for a patient with an acute illness i. Initial and Recertification CMN Initial and repeat blood gas study (ABG or oximetry test) i Clinical notes within 30 days prior to the initiation of oxygen iv. Face-to-face reevaluation within 30 days prior to the end of the third month supporting that the patient continues to require oxygen and is compliant with therapy b. Oxygen provided for a patient in a chronic stable state i. Initial CMN Initial blood gas study (ABG or oximetry test) i Clinical notes within 30 days prior to the initiation of oxygen 3. Prior Authorization for continuation of oxygen for up to an additional 24 months is required after the first 12 months. Documentation that must be submitted with the prior authorization request includes: a. Recertification CMN b. Blood gas study performed within 90 days of the end of 12th month c. Face-to-face reevaluation performed within 90 days of the end of the 12th month supporting that the patient continues to require oxygen and is compliant with therapy C. Prior Authorization is required for oxygen used with a positive airway pressure (PAP) device: 1. Prior Authorization is required for continuation of oxygen used with a PAP device for up to an additional nine months after the initial three month period. Documentation that must be submitted with the prior authorization request includes: a. A copy of the polysomnogram report that supports that use of a PAP device alone is insufficient to resolve hypoxemia; i.e., that Criteria II.A.4.a or b are met when the patient is using a PAP device; b. Face-to-face clinical reevaluation by the treating physician performed between the 31st and 91st day of use documenting improvement in symptoms; c. Documentation supporting that direct download of data from the device has been performed and that the patient has been adherent to therapy. Adherence to therapy is defined as use of PAP device greater than or equal to four hours per night on 70% of nights during a consecutive thirty day period during the first three months of initial usage. A repeat qualifying blood gas study is not necessary. 2. Prior Authorization is required for continuation of oxygen used with a PAP device for up to an additional 24 months after the first 12 months. Clinical notes supporting that the patient continues to use the PAP device and continues to use oxygen must be submitted with the prior Page 4

authorization request. A repeat qualifying blood gas study is not necessary. D. Prior Authorization is required for replacement of oxygen equipment. Documentation supporting the following must be submitted with the prior authorization request: 1. Equipment is malfunctioning, no longer under warranty and cannot be repaired, or 2. Equipment no longer meets the needs of the patient. E. Prior Authorization is not required for patients with cluster headache. F. UHA reserves the right to perform retrospective review using the above criteria to validate if services rendered met payment determination criteria. Documentation supporting that criteria are met must be kept in the patient's medical record and be made available on request. G. To request prior authorization, please go to UHA s website: https://uhahealth.com/page/priorauthorization-forms to submit via online. CPT Code E0424 E0431 E0434 E0439 E1353 E1390 E1391 E1392 E1405 E1406 K0738 Description Stationary compressed gaseous oxygen system, rental; includes container, contents, regulator, flowmeter, humidifier, nebulizer, cannula or mask, and tubing Portable gaseous oxygen system, rental; includes portable container, regulator, flowmeter, humidifier, cannula or mask, and tubing Portable liquid oxygen system, rental; includes portable container, supply reservoir, humidifier, flowmeter, refill adaptor, contents gauge, cannula or mask, and tubing Stationary liquid oxygen system, rental; includes container, contents, regulator, flowmeter, humidifier, nebulizer, cannula or mask, and tubing Oxygen related equipment regulator Oxygen concentrator, single delivery port, capable of delivering 85 percent or greater oxygen concentration at the prescribed flow rate Oxygen concentrator, dual delivery port, capable of delivering 85 percent or greater oxygen concentration at the prescribed flow rate, each Portable oxygen concentrator, rental Oxygen and water vapor enriching system with heated delivery Oxygen and water vapor enriching system without heated delivery Portable gaseous oxygen system, rental; home compressor used to fill portable oxygen cylinders; includes portable containers, regulator, flowmeter, humidifier, cannula or mask, and tubing V. Policy History Policy Number: M.DME.11.121120 Current Effective Date: 09/01/2016 Original Document Effective Date: 11/20/2012 Previous Revision Dates: 09/01/2016 PAP Approved: 11/20/2012 HCR_MPP-0127-090116 Page 5