Rescue Balloon Reposition of the Protruding Coil Loops during Endovascular Treatment of An Anterior Communicating Artery Aneurysm: A Case Report

Similar documents
Coiling of ruptured and unruptured intracranial aneurysms

Usefulness of Coil-assisted Technique in Treating Wide-neck Intracranial Aneurysms: Neck-bridge Procedure Using the Coil Mass as a Support

Repair of Intracranial Vessel Perforation with Onyx-18 Using an Exovascular Retreating Catheter Technique

Shallow aneurysms with wide necks pose a technical challenge

Shallow aneurysms with wide necks pose a technical challenge

Ruptured intracranial vertebral confluence

Initial Experience with the New Double-lumen Scepter Balloon Catheter for Treatment of Wide-necked Aneurysms

Irretrievable unraveled coil remaining in the vascular lumen between the cerebral aneurysm and puncture site

The self-expandable Neuroform2 stent (Boston Scientific,

Endovascular treatment of intracranial aneurysms with bare

First experience in intracranial aneurysm occlusion by balloon assisted coiling technique

NIH Public Access Author Manuscript J Am Coll Radiol. Author manuscript; available in PMC 2013 June 24.

Novel non-occlusive temporary endoluminal neck protection device to assist in the treatment of aneurysms in a canine model

Selective Endovascular Treatment of Intracranial Aneurysms with a Liquid Embolic: A Single-Center Experience in 39 Patients with 41 Aneurysms

ORIGINAL PAPER. 8-F balloon guide catheter for embolization of anterior circulation aneurysms: an institutional experience in 152 patients

Aneurysmal Rupture during Embolization with Guglielmi Detachable Coils: Causes, Management, and Outcome

High-Flow, Small-Hole Arteriovenous Fistulas: Treatment with Electrodetachable Coils

Endovascular treatment is increasingly used for ruptured

Interlocking Detachable Coil Occlusion in the Endovascular Treatment of Intracranial Aneurysms: Preliminary Results

Spontaneous Recanalization after Complete Occlusion of the Common Carotid Artery with Subsequent Embolic Ischemic Stroke

Aneurysms of the posterior inferior cerebellar artery

Stent-Assisted Coil Trapping in a Manual Internal Carotid Artery Compression Test for the Treatment of a Fusiform Dissecting Aneurysm

Semi-Jailing Technique Using a Neuroform3 Stent for Coiling of Wide-Necked Intracranial Aneurysms

COIL EMBOLIZATION OF WIDE NECK CEREBRAL ANEURYSMS USING BALLOON REMODELING TECHNIQUE-INITIAL EXPERIENCE IN PAKISTAN

Incidental aneurysms are now more frequently diagnosed

Intravascular stents for intracranial internal carotid and vertebral artery aneurysms: preliminary clinical experience

Long term follow-up of patients with coiled intracranial aneurysms Sprengers, M.E.S.

A Novel Technique of Microcatheter Shaping with Cerebral Aneurysmal Coil Embolization: In Vivo Printing Method

Stent-assisted Coil Placement in a Wide-necked Persistent Trigeminal Artery Aneurysm with Jailing of the Trigeminal Artery: A Case Report

Endovascular embolization with detachable coils has become

Can Flow diverters be used in acute SAH

Kissing Aneurysms at Fenestrated Proximal Basilar Artery: Double-barrel Stent-assisted Coiling Using Dual Closed-cell Stents

Journal of Neurological Sciences [Turkish] 34:(3)# 59; , doi: /jns.7801.

The incidence of subarachnoid hemorrhage (SAH) increases

lek Magdalena Puławska-Stalmach

Dept. of Neurosurgery, Division of Endovascular Neurosurgery, Medilaser Clinic, Tunja, Colombia 2

Subarachnoid hemorrhage secondary to ruptured intracranial

Endovascular coil embolization is an effective and popular

Y-Stent-Assisted Coil Embolization of Anterior Circulation Aneurysms

ENDOVASCULAR THERAPIES FOR ACUTE STROKE

Endovascular Treatment of Symptomatic Vertebral Artery Dissecting Aneurysms

Endovascular embolization of intracranial aneurysms (IA)

Department of Neurosurgery, Renmin Hospital of Wuhan University, Wuhan , Hubei Province, P.R.C; 2

The current optimized approach for patients with a ruptured

Mechanical Thrombectomy of Large Vessel Occlusions Using Stent Retriever Devices

Intraarterial Tirofiban Thrombolysis for Thromboembolisms During Coil Embolization for Ruptured Intracranial Aneurysms

Practical Feasibility and Packing Density of Endovascular Coiling Using Target Nano TM Coils in Small Cerebral

Intracranial vertebral artery (VA) dissection is not a common

Treatment of Unruptured Vertebral Artery Dissecting Aneurysms

A single center comparison of coiling versus stent assisted coiling in 90 consecutive paraophthalmic region aneurysms

The International Subarachnoid Aneurysm Trial 1 showed

Endovascular treatment for pseudoocclusion of the internal carotid artery

Endovascular Treatment of Anterior Choroidal Artery Aneurysms

Single-stage Coil Embolization for Kissing Aneurysms of the Internal Carotid Artery Using Enterprise Stent: Three Cases Reports

Neuroform Microdelivery Stent System

A Less Invasive Approach for Ruptured Aneurysm with Intracranial Hematoma: Coil Embolization Followed by Clot Evacuation

Endosaccular aneurysm occlusion with Guglielmi detachable coils for obstructive hydrocephalus caused by a large basilar tip aneurysm Case report

The Indication for Long-Term Oral Antiplatelet Therapy After Endovascular Embolization of Unruptured Intracranial Aneurysms

Pipeline Embolization Device

Concurrent Subarachnoid Hemorrhage and Acute Myocardial Infarction: A Case Report

Role, safety, and efficacy of WEB flow disruption: a review

ORIGINAL PAPER. Hemispheric divided coiling technique for coil embolization of middle- and large-sized intracranial aneurysms

The treatment of wide-neck and giant intracranial aneurysms

Endovascular treatment (EVT) of intracranial aneurysms is an

Thromboembolism is the most frequently reported complication

KIVILCIM YAVUZ, M.D., 1 SERDAR GEYIK, M.D., 1 ALMILA GULSUN PAMUK, M.D., 2 OSMAN KOC, M.D., 1 ISIL SAATCI, M.D., 1 AND H. SARUHAN CEKIRGE, M.D.

Comparison between Solitaire AB and Enterprise stent assisted coiling for intracranial aneurysms

Initial experience with implantation of novel dual layer flow-diverter device FRED

Endovascular coil embolization of cerebral aneurysms is associated

Coil Embolization of Cerebral Tiny Aneurysms

UPSTATE Comprehensive Stroke Center

Diffusion-Weighted Imaging Abnormalities after Percutaneous Transluminal Angioplasty and Stenting for Intracranial Atherosclerotic Disease

Case Report 1. CTA head. (c) Tele3D Advantage, LLC

Introducing a New Treatment Method for Brain Aneurysms

Two Cases of Carotid Artery Stenting Combined Balloon- and Self-expanding Stent for the Spontaneous Internal Carotid Artery Dissections

An intravenous thrombolysis using recombinant tissue

Treatment of a Ruptured Dissecting Vertebral Artery Aneurysm with Double Stent Placement: Case Report

Long-term effects of antiplatelet drugs on aneurysm occlusion after endovascular treatment

From its clinical introduction in 1991 in nonsurgical patients

Shaheen Shaikh, M.D. Assistant Professor of Anesthesiology, University of Massachusetts Medical center, Worcester, MA.

Aneurysms located at the vertebrobasilar junction are uncommon

TREATMENT OF INTRACRANIAL ANEURYSMS

Ruby Coil. Large Volume Detachable Coils

Alessandro Della Puppa

Detection & Treatments

Published December 16, 2010 as /ajnr.A2314

Since introduction of the Guglielmi detachable coil in 1991,

Y-Stent Assisted Coil Embolisation of Wide-Necked Aneurysms Using a New Fully Retrievable and Detachable Intracranial Stent: Report of Two Cases

Endovascular Treatment of Peripheral Cerebellar Artery Aneurysms

A Self-expanding Nitinol Stent (Enterprise) for the Treatment of Wide-necked Intracranial Aneurysms: Angiographic and Clinical Results in 40 Aneurysms

Endovascular embolization of intracranial aneurysms

FDA Executive Summary

First described by Sundt and Murphey, 1 the term blister

Patients with symptomatic atherosclerotic stenosis of the

Limitations of thrombolysis, including low recanalization

CASE REPORT. Alpha horizontal stent delivery for coil embolization of a broad-necked large basilar apex aneurysm: a case report

The Neuroform stent system (Boston Scientific, Natick,

Transcription:

Case Report Rescue Balloon Reposition of the Protruding Coil Loops during Endovascular Treatment of An Anterior Communicating Artery Aneurysm: A Case Report Hong Gee Roh, MD 1, Hyun-Seung Kang, MD 2, Pyoung Jeon, MD 3, Hong Sik Byun, MD 3 Protrusion of coil loop(s) and subsequent occlusion of the parent artery is one of the dreadful complications during endovascular coil embolization of cerebral aneurysm. Although protrusion of one or two coil loops may not cause adverse events and can be ignored in many instances, it can also compromise the parent artery in some cases with or without thrombus formation. We report a case of rescue balloon reposition of the protruding coil mass back into the aneurysm and recanalization of parent artery during embolization of the anterior communicating artery aneurysm. Key Words : Cerebral aneurysm; Complication; Endovascular treatment; Detachable coil; Balloon Protrusion of coil loop (s) into the parent artery of an aneurysm is one of the most feared complications of endovascular treatment with detachable coils (1). When it causes thrombus formation and/or parent artery steno-occlusion subsequently, the result of treatment can be disastrous. In this case report, we describe an our experience of rescue balloon reposition method for the complicated coil protrusion during endovascular embolization of an anterior communicating artery (ACoA) aneurysm. 1 Department of Radiology, Konkuk University Hospital, Seoul, Korea; 2 Department of Neurosurgery, Konkuk University Hospital, Seoul, Korea.; 3 Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea. Received May 12, 2006; accepted after revision July 31, 2006. Correspondence to: Hong Sik Byun, MD, Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Ilwon-dong, Kangnam-gu, Seoul 135-710, Korea. Tel. 82-2-3410-2518 Fax. 82-2-3410-2559 E-mail: hsbyun@smc.samsung.co.kr Neurointervention 2006;1:68-72 CASE REPORT A 51-year-old man presented with sudden onset of severe headache. Computed tomography (CT) revealed diffuse subarachnoid hemorrhage (SAH) with localized clot in the anterior interhemispheric cistern (Fig. 1A). His clinical status was Hunt and Hess grade II. Left internal carotid angiogram demonstrated a lobulated, wide-necked aneurysm of the ACoA (Fig. 1B). Under general anesthesia, a 6-F Envoy guiding catheter (Cordis Endovascular, Miami Lakes, Fl.) was placed in the left internal carotid artery (ICA). A Rebar-14 microcatheter (Micro Therapeutics, Inc., Irvine, CA) was then navigated into the aneurysm sac using 0.010 inch Silverspeed microguidewire (Micro Therapeutics). A complex Trufill detachable coil (5 mm diameter5 cm length, Cordis Endovascular) was placed within the larger aneurysm sac without difficulty (Fig. 2A). However, two coil loops protruded into the parent artery when the coil was detached (Fig. 2B). There was no adverse effect at that moment. Subsequently, two detachable coils were delivered into 68 Neurointervention 1, August 2006

Rescue Balloon Reposition of the Protruding Coil Loops during Endovascular Treatment of An Anterior Communicating Artery Aneurysm the aneurysm for further packing: 4 mm 6 cm soft Guglielmi detachable coil (GDC, Boston Scientific/ Target Therapeutics, Fremont, CA) and 2 mm 4 cm ultrasoft GDC. The protruding coils loops compromise the parent artery slightly more during the placement of the third coil. After intra-aneurysmal positioning of the three detachable coils, a small thrombus was observed at A1/A2 junction of the left anterior cerebral artery (ACA) around the protruding coil loops (Fig. 2C). Although 4000 U of heparin bolus was immediately administered intravenously, thrombus size increased more and more and the left anterior cerebral artery flow was arrested soon after (Fig. 2D). We then decided to do the rescue balloon reposition of the protruding coil mass. A 3.5 mm diameter 10 mm length, nondetachable Sentry microballoon catheter (Boston Scientific/ Target Therapeutics) was placed across the aneurysm neck (Fig. 3A). After 30-second inflation of the microballoon with care, the protruding coil mass and thrombus were successfully repositioned back into the aneurysm and ACoA and the left ACA was reopened completely (Fig. 3B and 3C). Final angiography demonstrated exclusion of the aneurysm sac and excellent flow in the left ACA with no residual narrowing (Fig. 3D). Although ACoA was occluded by the replaced coil mass, the contralateral ACA was supplied from the right internal carotid artery (Fig. 3E). The patient was recovered from anesthesia and woke up neurologically unchanged (Hunt and Hess grade II). He made a good recovery from the effects of SAH and was discharged home without neurological deficit. DISCUSSION Even with rapid improvement of the endovascular treatment of the cerebral aneurysm, placement of detachable coils is not without complication. Potential complications of detachable coil embolization include aneurysm perforation, failure to achieve complete packing of the aneurysm, parent vessel thrombosis, distal thromboembolism, coil protrusion or migration, coil stretch, parent artery occlusion, rebleeding, aneurysm regrowth, and so on. Particularly in cases of coil protrusion from the aneurysm, the thromboembolic complication may increase. Conventional management of protruding coils consists of removal and repositioning prior to electrolytic detachment, or the use of a snare or guidewire for removal when already detached (1, 2). Occasionally, the protruding coil is left in place even after multiple attempt to remove or reposition. Many cases of these situation can be treated with anticoagulation uneventfully. In some cases, however, A B Fig. 1. A. Initial CT scan shows diffuse subarachnoid hemorrhage, especially in the anterior subcallosal and interhemispheric area. B. Oblique lateral projection arteriogram of the left internal carotid artery reveals a wide-necked lobulated aneurysm at the anterior communicating artery (arrow). Neurointervention 1, August 2006 69

Hong Gee Roh, et al. the patient may suffer from cerebral infartion due to parent artery occlusion or distal thromboembolism. The balloon remodelling technique have been reported as a effective adjunct for the treatment of wide-neck aneurysm (3, 4). This method was originally used to prevent coil protrusion into the parent artery. This technique has provided interventional neuroragiologists with a greater chance to treat wide-neck aneurysms safely with detachable coils, although the procedure is more complicated and temporary flow arrest of the parent artery is required. In our case, we tried a technical modification of microballoon use for reposition of the protruded coil mass back into the aneurysm after intraaneurysmal coil placement. Snare retrival device can be used for protruding coil, but removing a significant coil mass is also technically A B C D 70 difficult, as well as potentially hazardous, with significant risk of thromboemboic complication, vessel perforation, and malpositioning of another coil(s) previously detached (1, 4, 5). We believe it is better to place the protruding coil loops back into the aneurysm sac by inflating the microballoon or microstent placement. There are a few reports of intracranial stenting for repositioning and trapping of the protruding coil loop(s) by use of coronary stent (2, 4). Currently, self-expandable intracranial stent - the Neuroform stent (Boston Scientific/Target) - can be navigated easily through the intracranial vasculature and deployed across a more distal aneurysm. This rescue technique with stent placement has become an attractive methocl to sequester herniated coils from the lumen of the parent artery (1, 6). There are, however, a Fig. 2. A. Left internal carotid arteriogram obtained after placement (before detachment) of the first coil within the larger sac of aneurysm, creating a good coil basket. There was no coil protrusion. B. After placement of the second coil. Two coil loops, which protruded immediately after detachment of the first coil, are noted in the the parent artery lumen at A1/A2 junction of the left anterior cerebral artery. There was no flow compromise at that time. C. After completion of the embolization procedure. The protruding coils loops compromise slightly more the left anterior cerebral artery, and a small thrombus has formed around the protruding coil loops, manifesting as a filling defect in the left anterior cerebral artery (arrow). D. Anterior-posterior (A-P) view of the left internal carotid arteriogram after IV heparinization. The left anterior cerebral artery flow was significantly diminished (arrow) and completely arrested soon after (not shown). Neurointervention 1, August 2006

A B C D E Fig. 3. A. Oblique Lateral nonsubtracted image obtained after placement the Sentry microballoon catheter through the occluded left anterior cerebral artery. Microballoon is positioned across the aneurysmal neck. B. Inflation of the Sentry microballoon pushes the protruding coil back into the aneurysm sac and anterior communicating artery. C. After the balloon was deflated, the coil maintains its position. The aneurysm is obliterated and the left anterior cerebral artery was completely recanalized. D. Completion arteriogram (A-P projection) demonstrates excellent flow in the left anterior cerebral artery. E. Although the anterior communicating artery was occluded, right anterior cerebral artery is supplied from the right internal carotid artery with good patency. limitation in this approach. Thrombogenicity of the stent remains a concern, as evidenced by cases of acute in-stent thrombosis and thromboembolism reported in early clinical series (7, 8). With the Neuroform stent, patients should be pretreated with antiplatelet drugs (a combination of aspirin and clopidogrel for at least 3 days before the procedure) (7). This can be easily achieved in patients with unruptured aneurysms but is problematic in patients with ruptured aneurysms. In such patients, it can be suggested that clopidogrel and aspirin be administered in loading doses during or shortly after the procedure through a nasogastric tube. Alternatively, the rescue balloon technique is used to avoid the problems of antiplatelet therapy in this situation. In conclusion, coil protrusion into the parent vessel may lead to thromboembolic complication even with heparinization, especially if the protruded coil loops compromise the vessel lumen. In such situations rescue reposition technique using microballoon or microstent should be considered. References 1. Dinc H, Kuzeyli K, Kosucu P, Sari A, Cekirge S. Retrieval of prolapsed coils during endovascular treatment of cerebral aneurysms. Neuroradiology 2006 Apr;48(4):269-72 2. Fessler RD, Ringer AJ, Qureshi AI, Guterman LR, Hopkins LN. Intracranial stent placement to trap an extruded coil during endovascular aneurysm treatment: technical note. Neurosurgery 2000 Jan;46(1):248-51 3. Cottier JP, Pasco A, Gallas S, Gabrillargues J, Cognard C, Drouineau J, Brunereau L, Herbreteau D. Utility of balloonassisted Guglielmi detachable coiling in the treatment of 49 cerebral aneurysms: a retrospective, multicenter study. AJNR Am J Neuroradiol 2001 Feb;22(2):345-51 4. Lavine SD, Larsen DW, Giannotta SL, Teitelbaum GP. Parent vessel Guglielmi detachable coil herniation during wide-necked aneurysm embolization: treatment with intracranial stent Neurointervention 1, August 2006 71

placement: two technical case reports. Neurosurgery 2000 Apr;46(4):1013-7 5. Sugiu K, Martin JB, Jean B, Rufenacht DA. Rescue balloon procedure for an emergency situation during coil embolization for cerebral aneurysms. Technical note. J Neurosurg 2002 Feb;96(2): 373-6 6. Lee YJ, Kim DJ, Suh SH, Lee SK, Kim J, Kim DI. Stent-assisted coil embolization of intracranial wide-necked aneurysms. Neuroradiology. 2005 Sep;47(9):680-9 7. Lanzino G, Kanaan Y, Perrini P, Dayoub H, Fraser K. Emerging concepts in the treatment of intracranial aneurysms: stents, coated coils, and liquid embolic agents. Neurosurgery 2005 Sep;57(3): 449-59 8. Benitez RP, Silva MT, Klem J, Veznedaroglu E, Rosenwasser RH. Endovascular occlusion of wide-necked aneurysms with a new intracranial microstent (Neuroform) and detachable coils. Neurosurgery 2004 Jun;54(6):1359-67 2006; 1: 68-72 Key Words : Cerebral aneurysm; Complication; Endovascular treatment; Detachable coil; Balloon 72 Neurointervention 1, August 2006