Use of Continuous Glucose Monitoring in the Detection and Prevention of Hypoglycemia

Similar documents
Early Patient and Clinician Experiences with Continuous Glucose Monitoring

Continuous Glucose Monitoring: Changing Diabetes Behavior in Real Time and Retrospectively

The MiniMed Continuous Glucose Monitoring System. JOHN J. MASTROTOTARO, Ph.D.

Updates in Diabetes Technology

Hypoglycemia Detection and Prediction Using Continuous Glucose Monitoring A Study on Hypoglycemic Clamp Data

Advances in Diabetes Care Technologies

Diabetes II Insulin pumps; Continuous glucose monitoring system (CGMS) Ernest Asamoah, MD FACE FACP FRCP (Lond)

Continuous Glucose Monitoring (CGM)

Diabetes Care 34: , with an increased risk of SH. In a

Comparison of the Numerical and Clinical Accuracy of Four Continuous Glucose Monitors

Clinical Value and Evidence of Continuous Glucose Monitoring

Long-term effects of continuous glucose monitoring on HbA 1c levels: An audit

Continuous Glucose Monitoring (CGM)

Advances in Diabetes Care Technologies

QUESTION 4. WHAT CLINICAL DATA ARE CURRENTLY AVAILABLE TO SUPPORT EXPANDED CGM COVERAGE BY PAYERS AS PERTAINS TO QUESTIONS 1 AND 3?

The recovery of cognitive function following hypoglycemia

hypoglycaemia unawareness keystone 18 July 2014

Artificial Pancreas Device System (APDS)

The In-Clinic Close Loop Experience in the US

CareLink. software REPORT REFERENCE GUIDE. Management Software for Diabetes

Agreement between Glucose Trends Derived from Three Simultaneously Worn Continuous Glucose Sensors

Supplementary Appendix

CONTINUOUS OR INTERMITTENT GLUCOSE MONITORING IN INTERSTITIAL FLUID

Real-Time Continuous Glucose Monitoring: From Application to Evaluation

Reduced Awareness of Hypoglycemia in Adults With IPPM

Today s Goals 10/6/2017. New Frontiers in Diabetes Technology. Disclosures

Cognitive function testing in studies of acute hypoglycaemia: rights and wrongs?

Insulin Delivery and Glucose Monitoring Methods for Diabetes Mellitus: Comparative Effectiveness

The Current Environment of CGM Technologies. Barry H. Ginsberg, M.D., Ph.D.

Assessing the value of the Ambulatory Glucose Profile in clinical practice

Making the Most of Continuous Glucose Monitoring

Control of Glycemic Variability for Reducing Hypoglycemia Jae Hyeon Kim

Continuous Glucose Monitoring

Preventing Hypoglycemia Using Predictive Alarm Algorithms and Insulin Pump Suspension

The Realities of Technology in Type 1 Diabetes

The transition from urinary

Accuracy Requirements for a Hypoglycemia Detector: An Analytical Model to Evaluate the Effects of Bias, Precision, and Rate of Glucose Change

NEW TECHNOLOGIES FOR MANAGING DIABETES ANGELA THOMPSON DNP, FNP-C, BC-ADM, CDE, FAANP

Performance Evaluations of Continuous Glucose Monitoring Systems: Precision Absolute Relative Deviation Is Part of the Assessment

Prediction of severe hypoglycemia. Additional information for this article can be found in an online appendix at

Advances in Diabetes Care Technologies

Report Reference Guide

DISCLAIMER: ECHO Nevada emphasizes patient privacy and asks participants to not share ANY Protected Health Information during ECHO clinics.

THE SHEFFIELD AREA PRESCRIBING GROUP. Position Statement for Prescribing of Freestyle Libre In Type 1 Diabetes. Date: March 2018.

Subjects and Methods 2017, 64 (8),

Coverage Guidelines. Continuous Glucose Monitors (CGMs)

Advances in Technology in the Treatment of Diabetes Mellitus 2017 How far have we come-how far are we going? Is there a final frontier?

First steps for success.

Norbert Hermanns, PhD 1,2, Beatrix Schumann, MD 2, Bernhard Kulzer, PhD 1,2, and Thomas Haak, MD 1,2. Original Article

Corporate Medical Policy

FreeStyle Mini Blood Glucose Results Are Accurate and Suitable for Use in Glycemic Clamp Protocols

Abstract CLINICAL APPLICATIONS. Objectives: Methods: Results: Conclusion: Journal of Diabetes Science and Technology

Learning Objectives. At the conclusion of this module, participants should be better able to:

Continuous or Intermittent Monitoring of Glucose in Interstitial Fluid. Original Policy Date

Medical Policy An independent licensee of the Blue Cross Blue Shield Association

Acute Glycemic Changes in Brain and Subcutaneous Tissue Measured by Continuous Glucose Monitoring System in Hereditary Hypertriglyceridemic Rat

Diabetes Technology Update. Sarah Konigsberg, MD Diabetes & Endocrine Assoc. April 7, 2018

JDRF Perspective on Closed Loop

PREVENTION OF NOCTURNAL HYPOGLYCEMIA USING PREDICTIVE LOW GLUCOSE SUSPEND (PLGS)

death if the deficit is prolonged. Children and adults exposed to hypoglycaemia can develop long-term impairment of cognitive function (Blattner,

REPORT INTERPRETATION

UvA-DARE (Digital Academic Repository) Hypoglycaemia in diabetes Schopman, J.E. Link to publication

Medical Policy An independent licensee of the Blue Cross Blue Shield Association

Report Reference Guide. THERAPY MANAGEMENT SOFTWARE FOR DIABETES CareLink Report Reference Guide 1

Medical Policy An independent licensee of the Blue Cross Blue Shield Association

Diabetes Management with Continuous Glucose Monitoring & Multiple Daily Injections. Aaron Michels MD

Continuous Glucose Monitoring: The Future of Diabetes Management

Artificial Pancreas Device Systems. Populations Interventions Comparators Outcomes Individuals: With type 1 diabetes

Continuous Glucose Monitoring System

Continuous Glucose Monitoring System

Accuracy of the 5-day FreeStyle Navigator Continuous Glucose Monitoring System: comparison with frequent laboratory reference measurements

Glycemic Variability:

Continuous Glucose Monitoring System

1. Continuous Glucose Monitoring

James J. Chamberlain, MD 1, Dana Dopita, RN, MSN, CDE 1, Emily Gilgen, RD, CD, CDE 1, and Annie Neuman, MPA, PA-C 1.

Inpatient Studies of a Kalman-Filter-Based Predictive Pump Shutoff Algorithm

Hypoglycemia Prediction with Subject-Specific Recursive Time-Series Models

Evaluation of a Continuous Glucose Monitoring System for Home-Use Conditions

Continuous Glucose Monitoring Devices Pharmacy Policy

Continuous Glucose Monitors for Diabetes Management

Presented by Dr. Bruce Perkins, MD MPH Dr. Michael Riddell, PhD

Continuous Glucose Monitoring and the Reality of Metabolic Control in Preschool Children With Type 1 Diabetes

Artificial Pancreas Device Systems. Populations Interventions Comparators Outcomes. pump. pump

1. What s the point of a network the case for research? 2. How to use CSII effectively

WOULD YOU LIKE TO REDUCE THE FEAR OF HYPOGLYCAEMIA FOR YOUR PATIENTS?

A Comparison of Time Delay in Three Continuous Glucose Monitors for Adolescents and Adults

Practical Strategies for the Clinical Use of Incretin Mimetics CME/CE. CME/CE Released: 09/15/2009; Valid for credit through 09/15/2010

THE ONLY SYSTEM^ CLINICALLY PROVEN TO REDUCE HYPOGLYCAEMIA

Welcome to CareLink Pro

In general: Hypoglycemia is common in insulin treated diabetes, but may also occur in people on oral medications, especially sulfonylureas/glinides.

INFUSYSTEMS USA. INFUSYSTEM

Pumps & Sensors made easy. OPADA ALZOHAILI MD FACE Endocrinology Assistant Professor Wayne State University

INSULIN INITIATION AND INTENSIFICATION WITH A FOCUS ON HYPOGLYCEMIA REDUCTION

Continuous or Intermittent Glucose Monitoring in Interstitial Fluid

Insulin Pumps and Glucose Sensors in Diabetes Management

Objectives. The Problem. We ve come a LONG way, Innovations in Diabetes Care and Management. Barbara Walz, RN, BSN, CDE April 26, 2018

Objectives. Glucose Monitoring Today. Tracking Glucose ISO Standards. Continuous Glucose Monitoring & Diabetes Management 3/7/2015

State of California Health and Human Services Agency Department of Health Care Services

Diabetes Management: Current High Tech Innovations

Transcription:

Journal of Diabetes Science and Technology Volume 1, Issue 1, January 2007 Diabetes Technology Society SYMPOSIUM Use of Continuous Glucose Monitoring in the Detection and Prevention of Hypoglycemia Howard A., M.D. Introduction Intensive diabetes therapy is complicated by an increased rate of hypoglycemia and the development of hypoglycemia unawareness. This presentation focuses on the potential role of real-time continuous glucose monitoring (CGM) in preventing hypoglycemia, and in overcoming this barrier to the implementation of intensive therapy. Issues to be discussed include the differences between capillary blood and interstitial glucose levels, the impact of lag times on sensor calibration and accuracy, and the importance of patient education in minimizing the risk for hypoglycemia from uncontrolled postprandial bolusing. Hypoglycemia: The barrier to intensive insulin therapy Impact of DCCT/EDIC Findings from the Diabetes Control and Complications Trial (DCCT) showed that patients in the intensively-treated group achieved A1c levels approximately 2 points below those achieved in the conventionally-treated group. The Epidemiology of Diabetes Interventions and Complications (EDIC) study, an epidemiologic follow-up of the DCCT subjects, showed a convergence of A1c levels at 4 years post- DCCT; patients in the conventional group improved their A1c somewhat, whereas glycemic control deteriorated in subjects from the experimental group. There have been no systematic evaluations to tease out the factors underlying this lapse in self-care and deterioration in control; however, published data indicate that this deterioration is not related to lack of healthcare insurance. A study by Thompson and colleagues, which looked at how patients have reacted to the findings reported by the DCCT, revealed that approximately 70% of those who wanted to improve their glycemic control cited fears of hypoglycemia as a significant barrier to intensifying their diabetes management. 1 In essence, there is a trade-off between reducing complications and increasing the risk for hypoglycemia. Hypoglycemia is the clinical risk barrier one faces when trying to initiate more intensive diabetes management. Hypoglycemia Unawareness As shown in Figure 1, adapted from work by Zammitt and Frier, declining glucose levels initiate a number of responses: insulin secretion is inhibited, followed by the release of counterregulatory hormones (glucagon and epinephrine) when glucose levels reach approximately 70 mg/dl; this is the basis for the consensus statement that proposes 70 mg/dl as the diagnostic criteria for hypoglycemia. 2 Continued decline in glucose eventually leads to neurologic dysfunction, widespread electroencephalogram (EEG) changes, cognitive dysfunction and severe neuroglycopenia. Counterregulatory abnormalities such as absent suppression of insulin secretion, blunted or absent glucagon response, and blunted adrenaline response further exacerbate the hypoglycemic condition in Type 1 and advanced Type 2 diabetes. Patients who experience frequent episodes of hypoglycemia often develop these abnormalities and lose their ability to detect hypoglycemia; this is referred to as hypoglycemia unawareness and it perpetrates a vicious cycle of recurrent hypoglycemia. Author Affiliation: Joslin Diabetes Center, Harvard Medical School, Boston, Massachusetts Abbreviations: (CGM) continuous glucose monitoring; (DCCT) Diabetes Control and Complications Trial; (EDIC) Epidemiology of Diabetes Interventions and Complications; (EEG) electroencephalogram; (FDA) Food and Drug Administration Key Words: continuous, diabetes, glucose, hypoglycemia, monitor, prevent Corresponding Author: Howard A., M.D., Joslin Diabetes Center, One Joslin Place, Boston, Massachusetts 02215, Howard.Wolper@joslin.harvard.edu J Diabetes Sci Technol 2007; 1:146-150 146

Figure 1. Hierarchy of Responses to Hypoglycemia There is strong evidence, however, that minimizing hypoglycemic episodes through more meticulous glucose control can actually reverse many of these counterregulatory defects. An early study by Fanelli and colleagues looked at patients with Type 1 diabetes who were being treated with multiple daily insulin injections. 3 Patients were converted to a more intensive regimen and closely followed for three months. The goal was to tighten glucose controls in order to minimize hypoglycemic episodes. Subjects underwent a standard hypoglycemic clamp at baseline, 2 weeks, and 3 months duration to measure threshold levels for hypoglycemic symptoms and neuroendocrine responses. As shown in Figure 2, the glycemic thresholds for symptoms and responses normalized after 3 months of meticulous glucose control and hypoglycemia prevention; even some of the glucagon responses recovered. The researchers concluded that hypoglycemia unawareness in Type 1 diabetes is largely reversible. Potential Utility of CGM to Prevent Hypoglycemia CGM can play a significant role in preventing hypoglycemia. Unlike traditional blood glucose monitoring, which looks at only a few points in time, CGM provides comprehensive data that track glucose levels 24 hours a day. This information allows patients to optimize their glycemic control and thus minimize the frequency and severity of hypoglycemic events. A recent study by Garg and colleagues looked at the accuracy, safety and clinical effectiveness of CGM in 91 subjects with Type 1 diabetes. 4 Researchers found that subjects who wore a real-time CGM sensor spent 21% less time hypoglycemic, 23% less time hyperglycemic and 24% more time within the target range of 81-140 mg/dl than subjects who used traditional blood glucose monitoring to guide treatment. It is important to note that there are several different sensors both on the market and awaiting approval from the Food and Drug Administration (FDA). These sensors vary in their performance characteristics and accuracy. Figure 3 presents data from a study by Clark and colleagues which compares the accuracy of the Medtronic CGMS device (FDA-approved) and Abbott FreeStyle Navigator (awaiting FDA approval) in terms of hypoglycemia detection. 5 147 www.journalofdst.org

Figure 3. Accuracy assessment of CGM versus reference blood glucose. Interstitial Fluid vs Capillary Blood Glucose Lag Time A key issue when comparing CGM technology with traditional blood glucose monitoring is that CGM sensors measure interstitial fluid, not capillary glucose. Glucose diffuses from capillary blood into interstitial fluid, resulting in a physiologic lag between glucose levels. The lag time can range from 5 to 15 minutes, depending on the rate of glucose change. Increasing glucose levels are reflected first in capillary blood. However, detecting decreases in glucose (after insulin injection or exercise) may be confounded by the placement of the CGM sensor. For example, if the CGM sensor is placed next to insulin-sensitive tissue, glucose level may decrease first in the interstitial fluid before it is reflected in capillary blood glucose. Because blood glucose concentration is regarded as the reference gold standard, these differences are an important issue in regard to assessment of the accuracy of CGM devices. Clearly, the physiologic lag adds complexity to the development of a reliable hypoglycemic warning alarm. Interstitial Glucose and Cognitive Performance Accurate hypoglycemia measurements are clinically important because they are a marker for patient risk of cognitive impairment and impending severe neuroglycopenia. For CGM devices, the question is whether and/or how well interstitial glucose correlates with cognitive function. Figure 2. Changes in symptoms and neuroendocrine responses resulting from meticulous glycemic control. Evans and colleagues looked at the time course for the onset of and recovery from acute hypoglycemia in healthy subjects. 6 Using standard glucose clamp technique, plasma glucose was allowed to fall rapidly to approximately 48 148 www.journalofdst.org

mg/dl for a period of 90 minutes; Cognitive function was assessed through a battery of sensitive tests throughout the hypoglycemic and recovery periods. The findings showed that while cognitive function became impaired immediately at the onset of hypoglycemia, counterregulatory hormone responses and symptomatic awareness of hypoglycemia were relatively delayed. During the 20-minute recovery period, cognitive function continued to be abnormal even after resolution of symptomatic awareness. (See Figure 4) Data from a smaller study by Cheyne and colleagues, which also used a hypoglycemic clamp, showed that recovery from hypoglycemia was delayed by an average of 26 minutes as measured by interstitial glucose. 7 A second issue rising from use of CGM technology is the tendency to over-bolus based on the data. Clearly, realtime data generated by CGM facilitates optimal glucose control; however, if patients overcompensate for rising glucose levels using frequent bolusing, they have an increased risk of becoming hypoglycemic. In essence, there is trade-off when using CGM with regard to hypoglycemia. On the one hand, there is an increased risk for hypoglycemia if patients are over-bolusing; on the other hand is the ability of the CGM device to detect hypoglycemic events. Just as some patients over-bolus to control hyperglycemia, we also see patients who reduce or discontinue their basal insulin in order to avoid hyperglycemia. This often occurs because patients do not understand the lag time between capillary and interstitial glucose, thereby assessing their glucose to be much lower than it actually is. As a result, they may end up overtreating the hypoglycemia, which, in turn, will lead to a cycle of significant glycemic variability. Figure 4. Delayed restoration of cognitive performance during recovery from hypoglycemia. To date, there have been no studies that examined the correlation between interstitial glucose and cognitive function in individuals with diabetes. However, an animal study by Nielsen and colleagues clearly demonstrated that measurements in the subcutaneous interstitial fat corresponded very closely with measurements in the central nervous system (CNS). 8 To summarize, interstitial fluid glucose concentration may be a better measure of functional status during periods of low glucose than capillary glucose concentration. Practical considerations with use of CGM An important consideration when using CGM technology is that sensor calibration needs to be performed when glucose is in a steady state, which relates back to the lag time issue discussed earlier. For example, if the patient performs the calibration when glucose is rising at 3 mg/dl/ min and there is a 10-minute lag, then there will be a discrepancy of approximately 30 mg/dl between the capillary glucose measurement and the interstitial glucose measurement. This will shift the curve upwards and make the sensor less accurate. Another issue that must be considered is the trade-off between sensitivity and specificity in terms of alarm thresholds. Some patients may feel that they are getting too many alarms. They respond by turning off their alarms and thus derive no benefit from them. This can be addressed by lowering the threshold when patients start using the device. Other patients who fear hypoglycemia, however, may be more tolerant of false alarms. These patients may benefit from starting off with higher thresholds, which lead to more false alarms but also detect more hypoglycemic episodes. Steps Ahead to Facilitate the Adoption of CGM Patient Education An important component of education will be to teach patients how to minimize their risk for hypoglycemia by avoiding over-bolusing. This will require thorough instruction in insulin pharmacodynamics (versus pharmacokinetics) as well as an understanding of the factors that affect postprandial glucose patterns. Patients must also understand when additional bolusing is indicated. At the same time, patients must learn how to minimize their risk for exaggerated rebound. As discussed earlier, this is often the result of overtreating hypoglycemia because they did not consider the lag time between interstitial and capillary glucose. Patients must be cautioned against inappropriate reduction or discontinuation of their basal 149 www.journalofdst.org

rates. They must also be taught not to rely on interstitial glucose data alone to assess their response to hypoglycemia. Glucose levels should always be confirmed with a capillary glucose test before initiating treatment. Technology Assessment and Improvement Outcome studies are critically important for obtaining insurance coverage for CGM technology. However, if the goal is to strike a balance between accuracy and prevention of hypoglycemia, we will have to assess each device on its own merit; we cannot generalize findings from any one study or device and apply it to all CGM technology. As far as improvements in CGM technology, a key focus should be on minimizing the risk for over-bolusing. It would be helpful to link the insulin-onboard feature on insulin pumps with the CGM screen to help temper patients taking extra boluses postprandially. Another feature would be to have a hypothetical insulin action profile superimposed on the sensor so that patients can more easily conceptualize how much insulin they have onboard. Incorporating a locking system into the insulin pump may also be helpful as a safety measure to prevent patients who are cognitively impaired (due to hypoglycemia) from inadvertently taking additional insulin. 3. Fanelli CG, Epifano L, Rambotti AM, Pampanelli S, Di Vincenzo A, Modarelli F, Lepore M, Annibale B, Ciofetta M, Bottini P, and al. et: Meticulous prevention of hypoglycemia normalizes the glycemic thresholds and magnitude of most of neuroendocrine responses to, symptoms of, and cognitive function during hypoglycemia in intensively treated patients with short-term IDDM. Diabetes 1993; 42:1683-1689. 4. Garg S, Zisser H, Schwartz S, Bailey T, Kaplan R, Ellis S, Jovanovic L: Improvement in Glycemic Excursions With a Transcutaneous, Real- Time Continuous Glucose Sensor: A randomized controlled trial. Diabetes Care 2006; 29:44-50. 5. Clarke WL, Anderson S, Farhy L, Breton M, Gonder-Frederick L, Cox D, Kovatchev B: Evaluating the Clinical Accuracy of Two Continuous Glucose Sensors Using Continuous Glucose Error Grid Analysis. Diabetes Care 2005; 28:2412-2417. 6. Evans ML, Pernet A, Lomas J, Jones J, Amiel SA: Delay in onset of awareness of acute hypoglycemia and of restoration of cognitive performance during recovery. Diabetes Care 2000; 23:893-897. 7. Cheyne EH, Cavan DA, Kerr D: Performance of a Continuous Glucose Monitoring System During Controlled Hypoglycaemia in Healthy Volunteers. Diabetes Technol Ther 2002; 4:607-613. 8. Nielsen JK, Djurhuus CB, Gravholt CH, Carus AC, Granild-Jensen J, Ørskov H, Christiansen JS: Continuous Glucose Monitoring in Interstitial Subcutaneous Adipose Tissue and Skeletal Muscle Reflects Excursions in Cerebral Cortex. Diabetes 2005; 54:1635-1639. Conclusions Fear of hypoglycemia poses a significant barrier to intensifying diabetes control. Frequent hypoglycemic episodes can impair normal counterregulatory responses and lead to hypoglycemia unawareness. CGM has the potential to help patients avoid hypoglycemia, improve their glycemic control and even reverse hypoglycemia unawareness. However, it is important that patients have reasonable expectations of what CGM technology can actually provide. They must receive adequate instruction to use CGM effectively. Disclosures: Member, Medical Advisory Board, Abbott Diabetes Care Member, Medical Advisory Board, J&J/Lifescan Grant support, Medtronic Diabetes References: 1. Thompson CJ, Cummings JF, Chalmers J, Gould C, Newton RW: How have patients reacted to the implications of the DCCT? Diabetes Care 1996; 19:876-879. 2. Zammitt NN, Frier BM:Hypoglycemia in Type 2 diabetes: pathophysiology, frequency, and effects of different treatment modalities. Diabetes Care 2005; 28:2948-61. 150 www.journalofdst.org