Evaluation of a desk top instrument for the automated development and immunochemical quantifi cation of fecal occult blood

Similar documents
EVALUATION OF QUANTITATIVE DETECTION OF FECAL HUMAN HAEMOGLOBIN FOR COLORECTAL CANCER SCREENING

Journal of Clinical Laboratory Instruments and Reagents, Vol. 34, No. 3 (June, 2011) Supplement

Faecal Immunochemical Testing (FIT) for Screening and Symptomatic Patients

FECAL OCCULT BLOOD TEST (FOBT) Common Guaiac versus Immunochemical Test

Title: Immunochemical Fecal Occult Blood Tests. Date: June 15, 2007

Appendix 1: Description of the 25 studies excluded from the meta-analysis of Sensitivity

Global colorectal cancer screening appropriate or practical? Graeme P Young, Flinders University WCC, Melbourne

Earlier stages of colorectal cancer detected with immunochemical faecal occult blood tests

Combination of Sigmoidoscopy and a Fecal Immunochemical Test to Detect Proximal Colon Neoplasia

Challenges for Colorectal Cancer Screening

T. Rubeca 1, S. Rapi 2, M. Confortini 1, M. Brogioni 2, G. Grazzini 1, M. Zappa 1, D. Puliti 1, G. Castiglione 1, S. Ciatto 1

Sensitivity of latex agglutination faecal occult blood test in the Florence District population-based colorectal cancer screening programme

The effectiveness of telephone reminders and SMS messages on compliance with colorectal cancer screening: an open-label, randomized controlled trial

FREQUENTLY ASKED QUESTIONS

CLIA Complexity: WAIVED INTENDED USE SUMMARY AND EXPLANATION

Procine sphingomyelin ELISA Kit

Sarvenaz Moosavi, 1 Robert Enns, 1 Laura Gentile, 2 Lovedeep Gondara, 2 Colleen McGahan, 2 and Jennifer Telford Introduction

CLIA Complexity: Waived

Bowel cancer screening and prevention

CerTest Turbilatex. A quantitative immunological latex method. FOB Calprotectin Transferrin H. pylori

Mouse C-Peptide ELISA Kit

Bowel Cancer Screening Exploiting science brings better medicine

Colorectal cancer screening

Information Pack for GP s The implementation of the Faecal Immunochemical Test (FIT) across the South West

PATIENT BROCHURE. 441 Charmany Dr 1 Madison WI, RX Only

Protn-Latex. For Determination of Protein in Latex. (Cat. # Latex, Latex) think proteins! think G-Biosciences

The New Grade A: USPSTF Updated Colorectal Cancer Screening Guidelines, What does it all mean?

CLIA Complexity: WAIVED

Guidelines for Colonoscopy Surveillance After Screening and Polypectomy: A Consensus Update by the US Multi-Society Task Force on Colorectal Cancer

North West London Pathology. Faecal Occult Blood testing. Mrs Sophie Barnes FRCPath Consultant Clinical Scientist

HBeAg and HBeAg Ab ELISA Kit

Morinaga Mouse C-peptide ELISA Kit

PROCEDURE. Sekisui Diagnostics OSOM ifob Rapid Test. Title: Procedure #: Institution: Prepared by: Date: Title: Accepted by: Date adopted: Title:

Rapid-VIDITEST FOB Blister

Optimizing implementation of fecal immunochemical testing in Ontario: A randomized controlled trial

NHS Bowel Cancer Screening Programmes: Evaluation of pilot of Faecal Immunochemical Test : Final report.

PROCEDURE MANUAL. Prepared By Date Adopted Supersedes Procedure # Review Date Revision Date Signature

CAPILLARYS HEMOGLOBIN

Quantitative immunochemical tests: evidence on accuracy and implementation considerations in the Czech MUDr.. Petr Kocna, CSc.

CEPHIA Consortium for the Evaluation and Performance of HIV Incidence Assays STANDARD OPERATING PROCEDURE

BACKGROUND. Fecal immunochemical tests (FIT) are an advanced fecal occult. METHODS. Individuals sampled consecutive stools, at home, with both FIT and

Immunochemical Faecal Occult Blood Test for Colorectal Cancer Screening: A Systematic Review

EVALUATION OF QUANTITATIVE FAECAL IMMUNOCHEMICAL TESTS FOR HAEMOGLOBIN

Human HIV (1+2) antigen&antibody ELISA Kit

Rotavirus Test Kit. Instructions For Use. Format: Cassette Specimen: Fecal Extract Catalog Number: VEL-001-ROTA

FOR LABORATORY USE ONLY

STANDARD OPERATING PROCEDURE TITLE: TOTAL IGE EIA (HYTEC 288)

Rat Leptin-HS ELISA FOR LABORATORY USE ONLY YANAIHARA INSTITUTE INC AWAKURA, FUJINOMIYA - SHI SHIZUOKA, JAPAN

Mouse C-peptide EIA. Cat. No. YII-YK013-EX FOR LABORATORY USE ONLY

IgG Antibodies To Toxoplasma Gondii ELISA Kit Protocol

Fecal immunochemical testing results and characteristics of colonic lesions

Worksheet. Worksheet. Worksheet. Worksheet. Student Performance Guide. Student Performance Guide

Mouse Leptin ELISA Kit Instructions

Colorectal Cancer Prevention Hospital Universitário São Paulo University

Human Obestatin ELISA

CHAPTER 7 Higher FIT cut-off levels: lower positivity rates but still acceptable detection rates for early stage colorectal cancers

LIPPINCOTT WILLIAMS AND WILKINS

PROCEDURE MANUAL. Prepared By Date Adopted Supersedes Procedure # Review Date Revision Date Signature

Human Influenza A (Swine Flu) Rapid test

Rubella virus IgG ELISA Kit

Human HBcAb IgM ELISA kit

Colorectal Cancer: Preventable, Beatable, Treatable. American Cancer Society

COLORECTAL CANCER SCREENING &THE FECAL IMMUNOCHEMICAL TEST (FIT) MATHEW ESTEY, PHD, FCACB CLINICAL CHEMIST

The Dutch bowel cancer screening program Relevant lessions for Ontario

LeadCare BLOOD LEAD ANALYZER. Quick Reference Guide

YK052 Mouse Leptin ELISA

Rat Leptin ELISA FOR LABORATORY USE ONLY YANAIHARA INSTITUTE INC AWAKURA, FUJINOMIYA - SHI SHIZUOKA, JAPAN

Rat C-Peptide EIA. Cat. No. YII-YK010-EX FOR LABORATORY USE ONLY

CLINICAL PRACTICE GUIDELINE FOR COLORECTAL CANCER SCREENING

Comparison of FIT performance in screening programs. Carlo Senore

Rubella Latex Agglutination Test

Citation for published version (APA): Wijkerslooth de Weerdesteyn, T. R. (2013). Population screening for colorectal cancer by colonoscopy

Human Alpha 1 microglobulin ELISA Kit

Mouse GLP-2 EIA FOR LABORATORY USE ONLY

Wellness Along the Cancer Journey: Cancer Types Revised October 2015 Chapter 4: Colorectal Cancer Overview

EpiQuik Circulating Acetyl Histone H3K18 ELISA Kit (Colorimetric)

Toxoplasma gondii IgM ELISA Kit

Hepatitis A virus IgM ELISA Kit

1101 First Colonial Road, Suite 300, Virginia Beach, VA Phone (757) Fax (757)

Toxoplasma gondii IgM ELISA Kit

Screening for GI Cancer Past Present and Future. Prof. Bob Steele University of Dundee

IV2-113E Use by. Invitron Glargine ELISA Kit REF LOT IVD. Definitions. English. For in-vitro diagnostic use. Instructions for use.

Rapid-VIDITEST. FOB+Tf. One step Fecal Occult Blood Card Test. Instruction manual

Updates in Colorectal Cancer Screening & Prevention

idc 20 AUTOMATED LIQUID-BASED CYTOLOGY SLIDE PREPARATION SYSTEM

Reagent Set DAS ELISA, Alkaline phosphatase label SRA 22001, SRA 23203, SRA 27703, SRA & SRA ToRSV, ArMV, GFLV, AnFBV and PDV

Mouse GLP-2 EIA. Cat. No. KT-374. For the quantitative determination of GLP-2 in mouse serum or plasma. For Research Use Only. 1 Rev.

Performance Characteristics and Comparison of Two Fecal Occult Blood Tests in Patients Undergoing Colonoscopy

Instructions for use. TSH rat ELISA. Please use only the valid version of the Instructions for Use provided with the kit AR E-8600

H.Pylori IgG

Rapid-VIDITEST. Calprotectin-Lactoferrin

BÜHLMANN fcal turbo. Calprotectin turbidimetric assay for professional use. Reagent Kit B-KCAL-RSET. Revision date:

Colorectal Cancer Screening. Dr Kishor Muniyappa 2626 Care Drive, Suite 101 Tallahassee, FL Ph:

CYTOMEGALOVIRUS (CMV) IgM ELISA Kit Protocol

Rapid-VIDITEST Swine Flu

Fecal H. pylori Antigen Rapid Test (Strip)

Thyroid Stimulating Hormone (S-TSH) Thyroid Stimulating

C-Peptide I and II (Rat) ELISA

STANDARD FOR PORCINE SEMEN QUALITY IN AI CENTRES

Transcription:

Med Sci Monit, 2006; 12(6): MT27-32 PMID: 16733493 WWW.MEDSCIMONIT.COM Diagnostics and Medical Technology Received: 2005.10.24 Accepted: 2006.01.10 Published: 2006.06.01 Authors Contribution: A Study Design B Data Collection C Statistical Analysis D Data Interpretation E Manuscript Preparation F Literature Search G Funds Collection Evaluation of a desk top instrument for the automated development and immunochemical quantifi cation of fecal occult blood Paul Rozen 1,2 ADEFG, Amal Waked 1 B, Alex Vilkin 1 ABC, Zohar Levi 1 BC, Yaron Niv 1,2 AEG 1 Department of Gastroenterology, Rabin Medical Center, Beilinson Hospital, Petach Tikva, Israel 2 Tel Aviv University Medical School, Tel Aviv, Israel Source of support: Eiken Chemical Company, Japan; Katzman Family Foundation, U.S.A. Summary MT Background: The guaiac fecal occult blood test (FOBT) for colorectal cancer (CRC) screening is user dependent and not specific for human hemoglobin (Hb). The automated-developed, quantitative, immunochemical human Hb FOBT (I-FOBT) is specific, allows for quality control and selection of a suitable Hb level, with optimal sensitivity and specificity, for colonoscopy. Material/Methods: We evaluated a desktop instrument, OC-MICRO (Eiken, Japan), which automatically develops and quantifies 50 fecal tests/hr for Hb; for ease of use, test reproducibility and stability and intrapatient daily I-FOBT variation; clinical evaluation included sensitivity and specificity for neoplasia in patients undergoing colonoscopy. Results: Five hundred patients prepared 3 fecal tests which were quantified for Hb, I-FOBT samples were: (1) repeatedly re-examined; (2) stored at 4 C or 20 C or 28 C and re-examined; (3) I-FOBT levels correlated with colonoscopic findings. Five I-FOBTs re-examined 6 times had no significant changes; 30 tests stored 21 days had a decay/day of: 0.3%±0.4 at 4 C (NS), 2.2%±1.7 at 20 C (NS) and 3.7%±1.8 at 28 C (P<0.05). Receiver operator characteristic curve analysis showed that at the 100 ng Hb/mL I-FOBT level 76.5% of CRCs and advanced adenomas were detected with a specificity of 95.3%. Conclusions: The instrument provided reproducible results and refrigerated I-FOBT samples were stable 21 days. An I-FOBT level can be chosen to provide optimal sensitivity and specificity for significant neoplasia. key words: Abbreviations: colorectal neoplasia fecal occult blood immunochemical test screening AAP advanced adenomatous polyp; CRC colorectal cancer; G-FOBT guaiac fecal occult blood test; Hb hemoglobin; HGD high-grade dysplasia; I-FOBT immunochemical fecal occult blood test; LGD low-grade dysplasia Full-text PDF: http://www.medscimonit.com/fulltxt.php?idman=8356 Word count: 2599 Tables: 1 Figures: 3 References: 25 Author s address: Prof. Paul Rozen, Dept. of Gastroenterology, Tel Aviv Medical Center, 6 Weizmann Street, Tel Aviv 64239, Israel, e-mail: rozen@tasmc.health.gov.il Current Contents/Clinical Medicine SCI Expanded ISI Alerting System Index Medicus/MEDLINE EMBASE/Excerpta Medica Chemical Abstracts Index Copernicus MT27

Diagnostics and Medical Technology Med Sci Monit, 2006; 12(6): MT27-32 BACKGROUND Population screening for asymptomatic colorectal cancer (CRC) or pre-cancerous adenomatous polyps is usually based on identifying the presence of fecal occult blood as bleeding almost inevitably occurs from clinically significant neoplasia [1,2]. The standard fecal occult blood test uses the chemical guaiac (G-FOBT), which is sensitive to the hemoglobin (Hb) peroxidase activity [1]. The guaiac test card is extensively used worldwide as it is inexpensive and its use in randomized, controlled, population screening trials had demonstrated a small but significant reduction in CRC mortality [2]. However, the standard G-FOBT has low sensitivity for clinically significant colorectal neoplasia and has low specificity due to its non-specificity for human Hb [2]. The test is also user dependent, which leads to the possibility of inaccurate preparation, storage, development and evaluation by inadequately trained personnel [1 4]. A further limitation of the G-FOBT is its sensitivity to dietary peroxidases, found in meat, fruits and vegetables, which can give a false positivity for neoplasia [1,2]. The G-FOBT has been extensively used, mainly in western countries, but not found useful in Asian countries because of their high-peroxidase diet [5]. For these reasons, screening tests have been developed based on the immunochemical detection of human fecal Hb. This test is specific, and so eliminates the need for diet restrictions. The office-developed immunochemical fecal occult blood tests (I-FOBT) improved test specificity and became the standard CRC screening test used in Japan [6 11]. However, for these office-developed tests, the I-FOBT manufacturers have predetermined the degree of sensitivity for Hb at a level similar to a sensitive G-FOBT [8]. A further improvement has been the introduction of instruments for the automated immunochemical development and quantification of fecal Hb. The automated-development allows for standardization and quality control and the Hb quantification allows selection of a suitable I-FOBT level for follow-up colonoscopy [5 7,10 12]. Such instruments have been developed by an Australian-American company (Insure, Enterix), and also in Japan (MagStream, Fujirebio and OC-MICRO Eiken) and only now are the latter instruments becoming available elsewhere [13,14]. A critical issue in the use of the FOBTs is the stability of the fecal Hb sample. Degradation of the Hb due to bacterial activity is temperature dependent. For this reason, it is usual to air-dry the prepared fecal sample-card used for both the G-FOBTs and office-developed I-FOBTs. They are then recommended to be kept in cool surroundings until development which should be no longer than 14 days from sample preparation [1,2]. A fluid-storage environment for the fecal sample and uncontrolled temperature will potentiate Hb degradation, and is not usually recommended and used for occult blood screening tests. However, this is the collection system used for some of the automated instruments for Hb quantification such as OC-MICRO. Little has been published in the English language on the I-FOBT test performed on the OC-MICRO instrument [15 19]. So, the use of such methodology for our population-screening program required our pilot evaluation of the test and instrument and their performance characteristics. Our clinical evaluation has been reported in detail [19]. Here we report on the technical features of the test as prepared by the screenee and of the instrument, and recommendations we made for its clinical use. MATERIAL AND METHODS Fecal sampling The fecal sampling device is a small probe that has a serrated tip. The probe is removed from the container tube and pushed several times into different areas of the stools and then reinserted into the tube, past a scrapper and through a membrane and thereby closing and sealing the sample tube. This action removes most of the excess feces and leaves a semi-standard amount of the stool in the probe tip serrations (Figure 1-left A,B,C) [17]. The tip is then in a closed amount of Hb-stabilizing buffer to produce a suspension. Each sample tube has its own bar code and before preparing the sample the patient writes his/her name and date of preparation on the tube. The examinees were requested to prepare 3 consecutive daily samples, which were double closed in zip-lock bags and refrigerated until returned to the developing laboratory where they were also kept at 4 C until development. Instrument and testing The instrument evaluated for developing and quantification of the I-FOBT is OC-MICRO, Eiken, Japan. This is a desktop instrument weighing 26 kg. It is self-contained with reagents, buffer, washing and fluid-disposal bottles, requiring a standard power supply (Figure 1-right). Technical information and evaluations performed in Japan is available in English translations of Japanese language publications [15 18]. Ten patients prepared fecal sample tubes that are loaded into the sample rack and in parallel there is another rack with the corresponding disposable reaction cells (Figure 1). The instrument is preheated to its operating temperature of 37 C, which is reached after 30 min. It then automatically punctures the membrane sealing the base of the fecal sample tubes with a needle-pipette which removes and then inserts 25 μl of the fecal-buffer solution into the corresponding reaction tube and with a second pipette mixes it with 60 μl of the provided latex-hb reagent and 300 μl of diluent buffer fluid (HEPES). Between sampling both pipettes are automatically washed inside and outside with distilled water. Following the development cycle, there is automatic flushing of the system (sample needle, tubing etc.) with a 5% sodium hypochlorite solution, which is collected into the disposal bottle. The entire cycle takes about 10 min. and about 50 samples/hr can be processed. The instrument automatically prints the results (nghb/ml of test fluid), giving also the bar code numbers, development date, as well as error messages. Data for 999 samples can be stored in the instrumen s memory for re-call and there is also the possibility to connect the instrument to a computer for data management. MT28

Med Sci Monit, 2006; 12(6): MT27-32 Rozen P et al Automated occult blood evaluation MT Figure 1. Left Stool probe and fecal sample storage tube. The closed tube is 8 cm long and 2 cm wide (A). The patient receives the closed tube, removes the fecal probe (B), which has a serrated tip that accumulates the fecal sample. The probe is then reinserted, but deeper into the tube, passed a scrapper and through a membrane (A-narrow arrow). The bottom compartment of the tube contains buffer solution for stabilizing the fecal specimen (C-narrow arrow). On each tube (C) there is a unique bar code and space to write name and date. The tubes are inserted inverted into the instrument sample rack and a needle pipette automatically punctures the base (A-thick arrow).right The open desktop OC-MICRO instrument and accessories. The instrument is 32 cm wide, 53 cm deep and 42 cm high. Top left bottle contains diluting solution, center bottle contains cleaning fluid, and right bottle contains distilled water. The right tray on the tabletop and that above it in the instrument (split arrows) hold the patient-prepared I-FOBT tubes ready for processing. The left tray on the tabletop is for the reaction tubes, where the I-FOBT-antibody reaction takes place and the Hb value calculated from the turbidity (right tray in the instrument). A qualified medical technician, who twice received instruction from the instrument company, performed the testing. I-FOBT analysis and quality control The immunochemical method is an anti-human HbA IgG antibody (prepared in rabbit) antigen reaction. The reagent is provided and had been prepared by absorbing the anti-human Hb antibodies onto polystyrene latex particles, suspended in an ammonium buffer. These reactions take place in an automatically heated, 37 C temperature-controlled system. The agglutination turbidity is read as an optical change at 600 nm and compared to a standard calibration curve that is prepared every 2 weeks and kept in the instrument s memory. Standardizing calibration is prepared for each day s analyses using the provided known high and low-value control test fluids. The range of measurements is 50 2000 ng Hb/mL, approximately equivalent to 40 400 μg Hb/g feces. The 100 ng Hb/mL level for determining positivity had been recommended, based on clinical follow-up of a screened population [12,13]. This was now reevaluated in our clinical study [19]. Evaluations performed These included evaluations of test reproducibility and fecal sample stability to different temperatures and durations of storage. Samples were taken from the tubing and disposal bottle for bacteriological examination. Clinical evaluation was by requesting patients, without visible rectal bleeding and scheduled for colonoscopy, to prepare 3 consecutive I-FOBTs following explanation of the tests and written instructions on preparing the I-FOBT [19]. The Ethics Committee of the Rabin Medical Center approved the clinical study in 2004. All participants gave an informed, signed consent for the I-FOBT and colonoscopy examination. Analysis and statistical methods Statistical analysis was performed using the SAS system for Windows, version 8.01. Results are given as means ±SD. Stability of the test measurements and effects of duration of storage and temperature were examined by analysis of variance with repeated measurements. Weekly changes in the stored I-FOBTs were determined by comparing the initial values measured with the lowest values measured during weeks 1, 2 and 3. For clinical correlation with the I-FOBT levels, the most severe pathology finding was recorded. Significant neoplasia included CRC or advanced adenomatous polyps (AAP). This latter category includes adenomas 10mm, or having more MT29

Diagnostics and Medical Technology Med Sci Monit, 2006; 12(6): MT27-32 12 10 end week1 end week2 end week3 100% 80% Change(%) 8 6 4 2 0-2 4 C (N=12) 20 C (N=10) 28 C (N=9) Sensitivity 60% 40% Cancer (N=6) 20% Advanced adenomas (N=28) Non-advanced adenomas (N=85) 0% 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 1-Specifivity Figure 2. Progressive changes in fecal Hb measurements at end of the first, second and third week s storage at 4 C, 20 C, and 28 30 C. The maximum changes at 20 C, and 28 30 C occurred by the end of the first week. The cumulative changes (decay) at 28 C were significantly different (P<0.05) from the initial measurements. than 20% of villous histology or any amount of high grade dysplasia independent of polyp size. A receiver operator characteristics curve (ROC) was then generated and the I-FOBT measurements correlated with the presence of neoplasia. RESULTS Instrument stability, bacteriology examination and test reproducibility During its use for more than 2 years, other than for routine periodic maintenance, it has remained free of technical problems. The instrument s tubing was found free of fecal bacteria, but the collection bottle was contaminated. The bottle is now emptied and cleaned daily with antiseptic fluid. The five prepared I-FOBTs that were quantified and then were each repeatedly examined 5 more times during 1 day, showed no significant variations in measurements, F (5,20) =0.24, P=0.66. Fecal test stability Thirty fecal tests, highly positive for Hb and 12 tests with low but elevated levels of fecal Hb, and stored at 4 C, 20 C or 28 30 C were repeatedly re-examined 2 3 times a week for 3 weeks. The calculated decay/day was 0.3%±0.4 at 4 C (NS), 2.2%±1.7 at 20 C (NS) and 3.7%±1.8 at 28 C (P<0.05). Their weekly changes in I-FOBT measurements, as compared to their initial values, are shown in Figure 2. At 20 C and at 28 C the maximum decay occurred by the end of the first week. At 4 C, I-FOBT samples maintained their elevated fecal Hb levels for 21 days. But 2 samples, with the lowest initial values, had repeated measurements <100ng Hb/mL by 3 weeks from time of preparation by the patient. Colonoscopy results The complete data from the initial 500 examinees was analyzed and is reported in detail elsewhere [19]. Clinically significant neoplasia was found in 34 patients, these included 6 with CRC and 28 with AAP. Non-advanced adenomas were found in a further 85 examinees. Figure 3. Receive operator characteristics curves demonstrating high sensitivity for colorectal cancer with high specificity. Most (72%) advanced adenomas were identified with a specificity of 95%. Fecal occult blood results For the 500 examinees, having 3 daily I-FOBT measurements, there was nonsignificant inter-daily variation in fecal Hb levels [19]. The ROC demonstrated good separation of I-FOBT levels in CRC and AAP-bearing patients from those with only non-advanced adenomas. These were obtained with high specificity of CRC and at a 95% specificity for 71% for AAP (Figure 3). This was obtained at the100 ng Hb/mL level by utilizing the highest results from all 3 days sampling. Similar analyses at lower and higher I-FOBT Hb levels are given in Table 1. DISCUSSION The technical evaluation of ease of use, degree of bacterial contamination, ease of test performance and reproducibility were found favorable by our technician. Evaluation included examination of the prepared fecal occult blood for stability at high ambient temperatures. This latter point was carefully evaluated and showed that the prepared I- FOBT could be 2 3 weeks in refrigeration without significant degradation of the test antigen. However, for low-elevated levels, the measurement could drop below the 100 ng Hb/mL threshold by 3 weeks even when refrigerated. So, when using this type of liquid I-FOBT sample, it is important to emphasize, to the patient and medical service, the correct storage temperature and the limitations to duration of storage; a 2-week time period is adequate for batch processing of accumulated test samples. An evaluation previously performed in Japan had shown sample stability, at room temperature, for 5 days [15]. We did not feel that this was suitable for our population as it did not take into consideration that at present we request 3 daily samples, which would then be sent for processing, and could be exposed for a longer duration of time to the uncontrolled room and transport temperature. The instrument-developed, quantitative fecal occult blood testing, allows the physician to choose the optimal fecal Hb threshold level that leads to a follow-up colonoscopy. To demonstrate this, we performed this study in high-risk for MT30

Med Sci Monit, 2006; 12(6): MT27-32 Rozen P et al Automated occult blood evaluation Table 1. Sensitivity, Specificity and Predictive Values for Significant Colorectal Neoplasia, (N=34)* at Differing Fecal Hb Levels (N=500)**, ***. Fecal Hb ng/ml Sensitivity N (%) Specificity % Predictive Value% Positive Negative 50 27 (79.4) 89.7 36.0 98.3 75 26 (76.5) 93.3 45.6 98.2 100 26 (76.5) 95.3 54.2 98.2 125 24 (70.6) 95.7 54.5 97.8 150 24 (70.6) 95.9 55.8 97.8 200 22 (64.7) 96.3 56.4 97.4 * 6 colorectal cancers and 28 advanced adenomatous polyps; ** Utilizing the highest of the 3 I-FOBT measurements in each patient; *** Derived from reference 19. MT CRC patients and symptomatic patients undergoing colonoscopy. From this study, we confirmed that the optimal sensitivity/specificity ratio was obtained at the I-FOBT threshold of 100 ng Hb/mL. This threshold allowed detection of all the cancers and the majority of advanced adenomas, giving for both together the optimal sensitivity of 76.5% with an acceptable specificity of 95.3%, at this round of screening in a group of patients at high-risk for CRC [2,19]. The assumption being that future rounds of annual I-FOBT screening would detect additional, but at present unidentified, significant neoplasia. As shown by the ROC analysis, the test does not identify the presence of non-advanced adenomas that have a low risk for CRC at present. The clinical conclusions drawn from this initial experience with OC- MICRO needs to be extended to a larger population. This will allow further evaluation of the optimal I-FOBT level for recommending colonoscopy follow-up and a calculation of cost-efficiency as compared to the present G-FOBT screening test being used. At present, we recommend collecting 3 annual fecal tests as, in this high-risk population, we have confirmed the additive clinical value of repeated occult blood testing. This recommendation is in contrast to the annual 2-day I-FOBT collection in the average-risk population, as routinely used in Japan, US and Australia and 1-day biennial testing as performed in Italy [11,12,20 22]. In the Japanese experience, the number of samples collected and threshold chosen were different from the experience in Italy, namely 2 annual samples and 150 ng/ml fecal Hb threshold in Japan vs. 1 biennial sample and 100 ng/ml threshold in Italy [20 22]. The goal is to extend this automated-developed, quantitative, I-FOBT to colorectal neoplasia screening of the asymptomatic average-risk population. This has been done with the InSure (Enterix, USA and Australia) test in pilot studies in Australia and to the public in the US [10,11]. Another automated test is MagStream (Fujirebio, Japan) developed in Japan and also being evaluated in Australia, France and Hong Kong [14,23]. It has been evaluated in a large colonoscopy screening study performed in Japan, but they used only a 1-time sample and did not provide details on the sample storage conditions before processing [24]. Outside of Japan, the automated version of OC-MICRO is being used in a large population, biennial, single sample study in Northern Italy [13]. It is also being used in a population study in Uruguay (Dr. E. Fenocchi, personal communication) and will be used in a large Spanish asymptomatic population screening trial (Dr. E. Carballo, personal communication). It is now being marketed in the USA as OC-AutoMicro 80 To facilitate average-risk compliance, there are two issues that need to be addressed. The provision of a toilet-disposable paper stool-collecting device facilitates preparing the test [25]. This is available in Japan and we are now evaluating such a device. As we have seen, the storage of the prepared I-FOBT in a refrigerator, until development, is important for maintaining the stability of the prepared test. This is critical in countries with high ambient temperatures, even when homes are air-conditioned. The opaque double zip-lock bags we provided answered some of the screenees hesitancy about keeping the prepared test transiently in their home refrigerator. This packaging has been improved. We have also advised adding a reusable cold pack to the kit for storing in the freezer and adding to the prepared samples when returning the prepared FOBTs to the developing laboratory. CONCLUSIONS We have found that this desktop, automated developed and quantified Hb version of the I-FOBT, to provide a sensitive test for detecting significant colorectal neoplasia with an acceptable specificity and consequent high negative predictive value. Its suitability for average-risk population screening will now be evaluated. Acknowledgments To the medical and secretarial staff of the Endoscopy Units and the patients for their cooperation. We thank Dr. Ester Shabtai and Doron Comaneshter for statistical analyses, Ms. Sally Zimmerman for secretarial assistance, the Katzman Family Foundation for supporting publication costs and Mr. Takuo Ichiyanagi for providing English language translations of Japanese publications. Instrument and reagents were provided by Eiken Japan, Alfa Wasserman Italy, and Pharmatrade Israel. MT31

Diagnostics and Medical Technology REFERENCES: 1. Young GP, Rozen P, Levin B: How should we screen for early colorectal neoplasia? In: Rozen P, Young GP, Levin B, Spann SJ, eds. Colorectal cancer in clinical practice. 2 nd ed. London: Taylor and Francis, 2005; 97 130 2. Young GP, St. John DJ, Winawer SJ, Rozen P: Choice of fecal occult blood tests for screening: recommendations based on performance characteristics in population studies: a WHO (World Health Organization) and OMED (World Organization for Digestive Endoscopy) report. Am J Gastroenterol, 2002; 97: 2499 507 3. Niv Y: Fecal occult blood test The importance of proper processing. J Clin Gastroenterol, 1990; 12: 393 95 4. Selinger RR, Nolman S, Dominitz JA: Failure of health care professionals to interpret fecal occult blood tests accurately. Am J Med, 2003; 114: 64 67 5. Wong BCY, Wong WM, Cheung KL et al: A sensitive guaiac faecal occult blood test is less useful than an immunochemical test for colorectal cancer screening in a Chinese population. Aliment Pharmacol Ther, 2003; 18: 941 46 6. Rozen P, Knaani J, Samuel Z: Performance characteristics and comparison of two immunochemical and two guaiac fecal occult blood screening tests for colorectal neoplasia. Dig Dis Sci, 1997; 42: 2064 71 7. Saito H, Soma Y, Nakajima M et al: A case-control study evaluating occult blood screening with Hemoccult test and an immunochemical hemagglutination test. Oncol Reports, 2000; 7: 815 19 8. Rozen P, Knaani J, Samuel Z: Comparative screening with a sensitive guaiac and specific immunochemical occult blood test within an endoscopy study. Cancer, 2000; 89: 46 52 9. Saito H, Yoshida Y: Mass screening: Japanese perspective. In: Young GP, Rozen P, Levin B, eds. Prevention and early detection of colorectal cancer. London: WB Saunders, 1996; 301 12 10. Young GP, St John DJB, Cole SR: Prescreening evaluation of a brushbased faecal immunochemical test for haemoglobin. J Med Screen, 2003; 10: 123 28 11. Young GP: Fecal immunochemical tests (FIT) vs. office-based guaiac fecal occult blood test (FOBT). Practical Gastroenterol, 2004; 3: 46 56 (www.practicalgastro.com) 12. Castiglione G, Grazzini G, Miccinesi G et al: Basic variables at different positivity thresholds of a quantitative immunochemical test for faecal occult blood. J Med Screen, 2002; 9: 99 103 13. Crotta S, Castiglione G, Grazzini G et al: Feasibility study of colorectal cancer screening by immunochemical faecal occult blood testing: results in a northern Italian community. Eur J Gastroenterol Hepatol, 2004; 16: 33 37 Med Sci Monit, 2006; 12(6): MT27-32 14. Launoy GD, Bertrand HJ, Berchi C et al: Evaluation of an immunochemical fecal occult blood test with automated reading in screening for colorectal cancer in a general average-risk population. Int J Cancer, 2005; 115: 493 96 15. Goto N, Fujimoto M, Ito K et al: Basic study of OC-SENSORμ, a compact fully automated immunochemistry analyzer for fecal occult blood tests. J Clin Lab Inst Reag, 2002; 25: 57 62 (In Japanese, English language translation available at international@eiken.co.jp) 16. Mizutani S, Fumitani M, Kaneshiro E et al: Fundamental evaluation of fully automated fecal occult blood analyzer OC-SENSORμ. Jap J Med Pharm Sci, 2002; 47: 769 73 (In Japanese, English language translation available at international@eiken.co.jp) 17. Horiuchi Y, Masubuchi J, Oikawa S et al: Evaluation of fully automated fecal occult blood analyzer OC-SENSOR neo and OC-SENSOR II. Jap Assoc Clin Lab Auto J, 2003; 28: 40 46 (In Japanese, English language translation available at international@eiken.co.jp) 18. Touzuka S, Aoyama K, Kamino T: Fundamental study on fully automated fecal occult blood immunochemical analyzer, OC-SENSOR neo. Med Exam Equip-Reagent, 2002; l25: 121 25. (In Japanese, English language translation available at international@eiken.co.jp) 19. Vilkin A, Rozen P, Levi Z et al: Performance characteristics and evaluation of an automated developed and quantitative, immunochemical, fecal occult blood screening test. Am J Gastroenterol, 2005; 100: 2519 26 20. Nakama H, Zhang B, Fattah ASMA: A cost-effective analysis of the optimum number of stool specimens collected for immunochemical occult blood screening for colorectal cancer. Eur J Cancer, 2000; 36: 647 50 21. Castiglione G, Zappa M, Grazzini G et al: Screening for colorectal cancer by faecal occult blood test: comparison of immunochemical tests. J Med Screen, 2000; 7: 35 37 22. Nakama H Zhang B, Zhang Y: Evaluation of the optimum cut-off point in immunochemical occult blood testing in screening for colorectal cancer. Eur J Cancer, 2001; 37: 398 401 23. Wong WM, Lam SK, Cheung KL et al: Evaluation of an automated immunochemical faecal occult blood test for colorectal neoplasia detection in a Chinese population. Cancer, 2003; 97: 2420 24 24. Morikawa T, Kato J, Yamaji Y et al: A comparison of the immunochemical fecal occult blood test and total colonoscopy in the asymptomatic population. Gastroenterology, 2005; 129: 422 28 25. Ahlquist DA, Schwartz S, Isaacson J, Ellefson M: A stool collection device: the first tep in occult blood testing. Ann Intern Med, 1988; 108: 609 12 MT32

Index Copernicus Global Scientific Information Systems for Scientists by Scientists www.indexcopernicus.com EVALUATION & BENCHMARKING PROFILED INFORMATION NETWORKING & COOPERATION VIRTUAL RESEARCH GROUPS GRANTS PATENTS CLINICAL TRIALS JOBS STRATEGIC & FINANCIAL DECISIONS Index Copernicus integrates IC Journal Master List Scientific literature database, including abstracts, full text, and journal ranking. Instructions for authors available from selected journals. IC Scientists Effective search tool for collaborators worldwide. Provides easy global networking for scientists. C.V.'s and dossiers on selected scientists available. Increase your professional visibility. IC Patents Provides information on patent registration process, patent offices and other legal issues. Provides links to companies that may want to license or purchase a patent. IC Virtual Research Groups [VRG] Web-based complete research environment which enables researchers to work on one project from distant locations. VRG provides: customizable and individually self-tailored electronic research protocols and data capture tools, statistical analysis and report creation tools, profiled information on literature, publications, grants and patents related to the research project, administration tools. IC Conferences Effective search tool for worldwide medical conferences and local meetings. IC Grant Awareness Need grant assistance? Step-by-step information on how to apply for a grant. Provides a list of grant institutions and their requirements. IC Lab & Clinical Trial Register Provides list of on-going laboratory or clinical trials, including research summaries and calls for co-investigators.