Rapid Determination of L-carnitine in Infant and Toddler Formulas by Liquid Chromatography Tandem Mass Spectrometry

Similar documents
Development Rapid Analytical Methods for Inositol as a Trace Component by HPLC and LC-MS/MS in Infant Formula

A Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer

Determination of Amantadine Residues in Chicken by LCMS-8040

Determination of 6-Chloropicolinic Acid (6-CPA) in Crops by Liquid Chromatography with Tandem Mass Spectrometry Detection. EPL-BAS Method No.

LC/MS/MS of Trichothecenes and Zearalenone in Wheat Using Different Sample Prep Methods

Analysis of anti-epileptic drugs in human serum using an Agilent Ultivo LC/TQ

Application Note. Author. Abstract. Introduction. Food Safety

Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition

Determination of β2-agonists in Pork Using Agilent SampliQ SCX Solid-Phase Extraction Cartridges and Liquid Chromatography-Tandem Mass Spectrometry

Amphetamines, Phentermine, and Designer Stimulant Quantitation Using an Agilent 6430 LC/MS/MS

Quantitative Analysis of Underivatized Amino Acids in Plant Matrix by Hydrophilic Interaction Chromatography (HILIC) with LC/MS Detection

Measuring Lipid Composition LC-MS/MS

DETERMINATION OF CANNABINOIDS, THC AND THC-COOH, IN ORAL FLUID USING AN AGILENT 6490 TRIPLE QUADRUPOLE LC/MS

Neosolaniol. [Methods listed in the Feed Analysis Standards]

Detection, Confirmation, and Quantification of Chloramphenicol in Honey, Shrimp and Chicken Using the Agilent 6410 LC/MS Triple Quadrupole

LC-MS/MS Method for the Determination of Tenofovir from Plasma

Quantification of lovastatin in human plasma by LC/ESI/MS/MS using the Agilent 6410 Triple Quadrupole LC/MS system

Determination of Aflatoxins in Food by LC/MS/MS. Application. Authors. Abstract. Experimental. Introduction. Food Safety

Fat-Soluble Vitamins Analysis on an Agilent ZORBAX Eclipse PAH Polymeric C18 Bonded Column

UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes

LC-MS/MS analysis of Chlorates in Milk and Whey Powder using the Agilent 6470 QQQ

Using Software Tools to Improve the Detection of Impurities by LC/MS. Application Note. Christine Miller Agilent Technologies.

Authors. Abstract. Introduction. Environmental

Determination of Multi-Residue Tetracyclines and their Metabolites in Milk by High Performance Liquid Chromatography - Tandem Mass Spectrometry

Application Note. Agilent Application Solution Analysis of ascorbic acid, citric acid and benzoic acid in orange juice. Author. Abstract.

Determination of B-vitamins in Energy Drinks by CE/MS/MS

Modified QuEChERS for HILIC LC/MS/MS Analysis of Nicotine and Its Metabolites in Fish

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine

MALAYSIAN MALAYSIAN COCOA WORKSHOP ON THE SAFE USE OF PESTICIDES IN COCOA AND HARMONIZED

Determination of red blood cell fatty acid profiles in clinical research

LC-MS/MS Method for the Determination of 21 Opiates and Opiate Derivatives in Urine

F. Al-Rimawi* Faculty of Science and Technology, Al-Quds University, P.O. Box 20002, East Jerusalem. Abstract

LC/MS/MS Separation of Cholesterol and Related Sterols in Plasma on an Agilent InfinityLab Poroshell 120 EC C18 Column

Dienes Derivatization MaxSpec Kit

Mass-Based Purification of Natural Product Impurities Using an Agilent 1260 Infinity II Preparative LC/MSD System

Carnitine / Acylcarnitines Dried Blood Spots LC-MS/MS Analysis Kit User Manual

Determination of Bisphenol A in Milk Powder using a Chromolith HighResolution RP-18 endcapped column

4.5 Minute Analysis of Benzodiazepines in Urine and Whole Blood Using LC/MS/MS and an Ultra Biphenyl Column

[ APPLICATION NOTE ] Profiling Mono and Disaccharides in Milk and Infant Formula Using the ACQUITY Arc System and ACQUITY QDa Detector

Analysis of mycotoxins in food matrices using the Agilent Ultivo Triple Quadrupole LC/MS

Application Note. Authors. Abstract. Food

A RAPID AND SENSITIVE ANALYSIS METHOD OF SUDAN RED I, II, III & IV IN TOMATO SAUCE USING ULTRA PERFORMANCE LC MS/MS

Meeting Challenging Requirements for the Quantitation of Regulated Growth Promoters Dexamethasone and Betamethasone in Liver and Milk

Determination of Bath Salts (Pyrovalerone Analogs) in Biological Samples

Analysis of Acrylamide in French Fries using Agilent Bond Elut QuEChERS AOAC kit and LC/MS/MS

Cannabinoid Profiling and Quantitation in Hemp Extracts using the Agilent 1290 Infinity II/6230B LC/TOF system

Journal of Chemical and Pharmaceutical Research

Method Validation for the Analysis of Multiple Weight Loss Drugs in Dietary Supplement Materials by LC-MS/MS

Pantothenic Acid. Shang-Jing Pan, Ph.D. Abbott Nutrition Columbus, Ohio, USA

Supporting Information

Cannabinoid Quantitation Using an Agilent 6430 LC/MS/MS

Reduced Ion Suppression and Improved LC/MS Sensitivity with Agilent Bond Elut Plexa

Enhanced LC-MS Sensitivity of Vitamin D Assay by Selection of Appropriate Mobile Phase

Analysis of Amino Acids Derived Online Using an Agilent AdvanceBio AAA Column

High-Throughput, Cost-Efficient LC-MS/MS Forensic Method for Measuring Buprenorphine and Norbuprenorphine in Urine

Vitamin D Metabolite Analysis in Biological Samples Using Agilent Captiva EMR Lipid

A MODIFICATION OF GAS CHROMATOGRAPHY METHOD FOR THE DETERMINATION OF FATTY ACID COMPOSITION OF MILK FAT

vii LIST OF TABLES TABLE NO DESCRIPTION PAGE 1.1 System Suitability Parameters and Recommendations Acidic and Alkaline Hydrolysis 15

Measuring Phytosterols in Health Supplements by LC/MS. Marcus Miller and William Schnute Thermo Fisher Scientific, San Jose, CA, USA

PHOTOCATALYTIC DECONTAMINATION OF CHLORANTRANILIPROLE RESIDUES IN WATER USING ZnO NANOPARTICLES. DR. A. RAMESH, Ph.D, D.Sc.,

Validation of Changes to the USP Assay Method for Ibuprofen Tablets

Efficient Quantitative Analysis of THC and Metabolites in Human Plasma Using Agilent Captiva EMR Lipid and LC-MS/MS

Quantitative Analysis of Opiates in Urine Using RRHT LC/MS/MS. Application. Authors. Introduction. Abstract. Forensics

UPLC-MS/MS Analysis of Azole Antifungals in Serum for Clinical Research

Transferring a Method for Analysis of DNPH-Derivatized Aldehydes and Ketones from HPLC to UHPLC

Mycotoxin Analysis in Infant Formula Using Captiva EMR Lipid Cleanup and LC/MS/MS

All stocks and calibration levels were prepared in water: methanol (50:50) v/v to cover range of all steroid concentrations (refer Table 1).

Application Note LCMS-108 Quantitation of benzodiazepines and Z-drugs in serum with the EVOQ TM LC triple quadrupole mass spectrometer

CONTENT. i iv ix. SVKM s NMIMS, School of Pharmacy and Technology Management

RP-HPLC Analysis of Temozolomide in Pharmaceutical Dosage Forms

World Journal of Pharmaceutical Research

Determination of Benzoate in Liquid Food Products by Reagent-Free Ion Chromatography

SUPPORTING INFORMATION FOR: CONCENTRATIONS OF POLYBROMINATED DIPHENYL ETHERS, HEXABROMOCYCLODODECANES AND TETRABROMOBISPHENOL-A IN BREAST MILK FROM

Vitamin D3 and related compounds by ESI and APCI

LC/MS Method for Comprehensive Analysis of Plasma Lipids

Analysis of Testosterone, Androstenedione, and Dehydroepiandrosterone Sulfate in Serum for Clinical Research

Identification and Quantification at ppb Levels of Common Cations and Amines by IC-MS

GC-MS/MS Analysis of Benzodiazepines Using Analyte Protectants

Determination of Clarithromycin in Human Plasma by LC-EI Tandem Mass Spectrometry: Application to Bioequivalence Study

Supplementary Information. Effects of Perfluorooctanoic Acid on Metabolic Profiles in Brain and Liver of Mouse by a

METHOD 8316 ACRYLAMIDE, ACRYLONITRILE AND ACROLEIN BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC)

Mycotoxin Analysis in Peanut Butter Using Captiva EMR Lipid Cleanup and LC/MS/MS

Quantitative Analysis of Amphetamine-Type Drugs by Extractive Benzoylation and LC/MS/MS. Application. Introduction. Authors. Abstract.

Development and Validation of RP-HPLC Method for the Estimation of Gemigliptin

J Pharm Sci Bioscientific Res (4): ISSN NO

2D-LC as an Automated Desalting Tool for MSD Analysis

Uptake and Metabolism of Phthalate Esters by Edible Plants

Application of LC/Electrospray Ion Trap Mass Spectrometry for Identification and Quantification of Pesticides in Complex Matrices

Qualitative and quantitative determination of cannabinoid profiles and potency in CBD hemp oil using LC/UV and Mass Selective Detection

Quantitative Analysis of Vit D Metabolites in Human Plasma using Exactive System

retardation in infants. A wide variety of analytical methods for the analysis of

Journal of Chemical and Pharmaceutical Research

Pelagia Research Library

Fast and simultaneous analysis of ethanol metabolites and barbiturates using the QTRAP 4500 LC-MS/MS system

Analysis of Vitamins Using an SFC/UHPLC Hybrid System with a Triple Quadrupole LC/MS for Quantification

Analysis of Cholesterol-Lowering Drugs (Statins) Using Dried Matrix Spot Technology

Rapid and sensitive UHPLC screening of additives in carbonated beverages with a robust organic acid column

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS

Extraction of Aflatoxin M1 From Infant Formula Using ISOLUTE Myco SPE Columns prior to LC-MS/MS Analysis

Highly Repeatable Ultra Low Detection of Estradiol Using Triple Quadrupole GC/MS in NCI Mode

Transcription:

Korean J. Food Sci. An. Vol. 34, No. 6, pp. 749~756 (2014) 2014 Korean Society for Food Science of Animal Recources DOI http://dx.doi.org/10.5851/kosfa.2014.34.6.749 ISSN 1225-8563 eissn 2234-246X ARTICLE Rapid Determination of L-carnitine in Infant and Toddler Formulas by Liquid Chromatography Tandem Mass Spectrometry Jang-Hyuk Ahn 1, Byung-Man Kwak 2, Jung-Min Park, Na-Kyeoung Kim, and Jin-Man Kim* Department of Food Science and Biotechnology of Animal Resources, Konkuk University, Seoul 143-701, Korea 1 KOTITI Testing & Research Institute, Seongnam 462-807, Korea 2 Food Safety Center, Research and Development Institute, Namyang Dairy Co., Ltd., Gongju 339-914, Korea Abstract A rapid and simple analytical method for L-carnitine was developed for infant and toddler formulas by liquid chromatography tandem mass spectrometry (LC-MS/MS). A 0.3 g of infant formula and toddler formula sample was mixed in a 50 ml conical tube with 9 ml water and 1 ml 0.1 M hydrochloric acid (HCl) to chemical extraction. Then, chloroform was used for removing a lipid fraction. After centrifuged, L-carnitine was separated and quantified using LC-MS/MS with electrospray ionization (ESI) mode. The precursor ion for L-carnitine was m/z 162, and product ions were m/z 103 (quantitative) and m/z 85 (qualitative), respectively. The results for spiked recovery test were in the range of 93.18-95.64% and the result for certified reference material (SRM 1849a) was within the range of the certificated values. This method could be implemented in many laboratories that require time and labor saving. Keywords: L-carnitine, LC-MS/MS, analytical method, infant formula, toddler formula Introduction Carnitine is a very important nutritional ingredient included in infant and toddler formula. In particular, L- carnitine among different forms of carnitine is also called vitamin Bt and carnitine utilized for food generally means L-carnitine (Steiber et al., 2004). Meat and dairy products are the main dietary supply source of L-carnitine, and normally carrying L-carnitine is essential for the smooth function of cardiac muscle, skeletal muscle, and many different tissues. It is indicated on the products with being added to the internationally produced sold formulated milk powder and infant and toddler formula as nutritional supplement ingredients, owing to this dietetic value and necessity. L-carnitine plays a role in helping decompose fat in the human body. Therefore, in case it is insufficient, energy produced in decomposing fatty acid is not generated, as fatty acid is not decomposed well (Olpin, 2005). For this reason, carnitine is much used as drug or food additives helpful to a diet. Besides, it plays a role in eliminating toxic substances from cell. In case of infant, the *Corresponding author: Jin-Man Kim, Department of Food Science and Biotechnology of Animal Resources, Konkuk University, Seoul 143-701, Korea. Tel: +82-2-450-3688, Fax: +82-2-455-1044, E-mail: jinmkim@konkuk.ac.kr activity of enzyme necessary for the last step of carnitine synthesis is only 12% of normal adult, and reaches the level of 30% of adult at 2-6 years old. Only if they are approximately 15 years old, the activity of carnitine reaches the level of adult. Hence ingestion through breast milk or infant and toddler formula from the outside is essential (Olpin, 2005). L-carnitine is an amphoteric ion, and is a polar non-volatile compound without chromospheres. It can be analyzed with high-performance liquid chromatography (HPLC) or gas chromatography (GC) (Gong-Xin and Terry, 2000; Sowell et al., 2011). In case of HPLC, in being detected after carnitine is derivatized into bromophenacyl ester, an organic acid acts as interfering substance. Accordingly, limit of quantitation (LOQ) is shown to be high. In case of analysis with gas chromatography-mass spectrometry (GC-MS), after carrying out alkaline hydrolysis, methyl ester is made from free acid, or base is used as catalyst, and then cyclization is carried out, and then demethylated derivative is detected (Vogt and Seim, 1996). However, there are disadvantages of long chromatography analysis time and complicated sample preparation process in derivatization. There is a method that can carry out the quantitative analysis of L-carnitine by utilizing the choline test method for the formulated milk powder and milk as an offi- This is an open access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licences/ by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. 749

750 Korean J. Food Sci. An., Vol. 34, No. 6 (2014) cial analytical method (AOAC Official Method 999.14, 2003). And simultaneous analysis method utilizing liquid chromatography-mass spectrometry (LC-MS) of free carnitine and total choline content was published in AOAC official journal (Andrieux et al., 2008). Besides, a method through liquid chromatography-tandem mass spectrometry (LC-MS/MS) instrumental analysis was also presented (Starkey et al., 2008). AOAC official test method and a method printed in the journal is accurate and precise, and is a close examination method utilizing up-to-date instrument, LC-MS/MS, and is a method suitable for examining a very small amount of L-carnitine. However, sample preparation of emulsified foods such as infant formulas is not easy. In general, sample preparation process of emulsified foods goes through alkali decomposition or fat-free process. And this was not considered in the previous paper of L-carnitine analysis. This study aims at introducing sample preparation method in consideration of the matrix characteristics of formulated milk powder, and aims at developing a simple test method that requires a smaller amount of test materials and time than the conventional method. Besides, it is intended to improve AOAC journal method by the precise instrumental analysis that has simple sample preparation method and utilizes LC-MS/MS. Materials and Methods Standard, Samples, and reagents L-carnitine (Levocarnitine, Cat. No. 1359903) was purchased from the US Pharmacopeial Convention (USP, USA) for use as the reference standard material. Purity was 99.9% (0.999 mg/mg). A stock solution of 1000 μg/ ml L-carnitine was dissolved in water, and diluted to the required concentrations of 1, 5, 10, 25, and 50 ng/ml to make the standard working solutions. The infant and toddler formulas used in this study were purchased from a local market and stored at 4 C. A certified reference material (CRM), infant formula SRM 1849a (NIST, USA), was used in the recovery tests to develop the method. The amount of L-carnitine in SRM 1849a was 136±14 mg/kg (coverage factor, k=2.00). Heptafluorobutyric acid (HFBA) was purchased from Sigma- Aldrich (USA) and 0.1 M hydrochloric acid (HCl) was purchased from Junsei Chemical (Japan). Water, methanol, and chloroform for HPLC grade were purchased from Merck (Germany). Ultrapure water was obtained using a Banstead Diamond TII system (USA). The distilled water had a resistance of 18.0 MΩ.. Sample preparation A method for sample preparation was based on the previous study (Starkey et al., 2008), however, additional techniques were used for protein removal through the acid hydrolysis and lipid removal through the organic solvent extraction. Samples containing 0.3 g was placed in 50 ml conical tubes and dissolved in 9 ml of distilled water and 1 ml of 0.1 M HCl. The ph for sample solution adjusted from control (6.6-6.8) to 4.0, this is in order to remove a casein which makes up about 80% of the milk protein fraction. After the ph was lowered than 4.6 (isoelectric point of casein), it was intended to isoelectric protein precipitation (Lovrien et al., 1997). After the addition of 10 ml of chloroform for removing a lipid fraction (Sullivan and Carpenter, 1993), the solutions were covered with a screw cap and vigorously mixed for 1 min using a vortex mixer at maximum speed. The tube was then centrifuged for 5 min at 3000 rpm at 4 C. An aqueous upper layer of the solution was filtered by a 0.45 μm polytetrafluoroethylene (PTFE) filter, and transferred to a vial for instrumental analysis. Operating conditions The operating conditions for instrumental analysis were determined by analogy with previous reports using LC- MS/MS (Starkey et al., 2008). An Agilent 1200 HPLC system (Agilent, USA) equipped with a Zorbax Eclipse C 8 (4.6 mm 150 mm, 5 μm) reverse-phase column and a 6410 triple quadrupole LC/MS tandem MS system were used for analysis of L-carnitine. The mobile phase was composed of 0.1% HFBA in water solution (90%) and 0.1% HFBA in methanol solution (10%) for isocratic flow. Flow rate was 0.3 ml/min, column temperature was 30 C, and injection volume was 10 μl. Solvents for HPLC grade were filtered by 0.45 μm membrane and used after ultrasonic degassing. The specific conditions for LC-MS/ MS used for the analysis are shown in Table 1. Validation of the method The developed method was validated by the AOAC guidelines for single laboratory validation of chemical methods (AOAC International, 2002). For method validation, there were evaluated the following 5 parameters; linearity, limit of detection (LOD), limit of quantification (LOQ), method detection limit (MDL), and results for recovery test. The linearity of the method was characterized by the average coefficient of determination (r 2 ) and was calculated using five consecutive standard curves. The LOD and LOQ were determined by diluting an L-

Rapid Determination of L-carnitine by Liquid Chromatography Tandem Mass Spectrometry 751 Table 1. Liquid chromatography-tandem mass spectrometry conditions for L-carnitine (a) LC (b) MS/MS Parameter Column Detector Mobile phase Flow rate Condition Agilent Zorbax Eclipse C 8 (4.6 mm 150 mm, 5 µm) MS/MS 90% = 0.1% Heptafluorobutyric acid in water : mobile phase A 10% = 0.1% Heptafluorobutyric acid in methanol : mobile phase B 0.3 ml/min Column temperature 30 Running time 20 min Injection volume 10 ul Parameter Ion source Polarity Condition ESI (Electro spray ionization) Positive Nebulizer gas N 2 Nebulizer pressure 40 psi Gas flow 10 L/min Ion spray voltage 5000 V Source temp. 350 Resolution Q1(unit) Q3(unit) Scan mode MRM (Multiple reaction monitoring) MRM condition Retention Time (min) Compound Precursor ion (m/z) Product ion (m/z) Dwell (ms) Fragmentor (V) Collision Energy (V) 12.86 L-carnitine 162 103 Quantitative 100 116 12 85 Qualitative 100 116 16 carnitine standard working solutions to obtain signal to noise ratios of ~3:1 for LOD and ~10:1 for LOQ. MDL was determined by multiplying the solvent volume (ml) of the LOD and dividing by the sample amount (g). The recovery tests of L-carnitine were carried out by spiking test with infant formula sample, and confirmation of certificated value for SRM 1849a. For the spiking test, spiked levels of infant formula was 50 mg/kg for 0.3 g of sample and the results of the quantitative analysis were compared to that obtained for samples without the standard solution. Monitoring test The three types of infant formulas (milk-based powder, milk-based liquid and cereal-based powder) and toddler formula (milk-based powder) were tested for the determination of L-carnitine contents. Total 32 samples were used for monitoring test. All samples were purchased from a local market and stored at room temperature. Results and Discussion Optimization for ph in sample extract For sample preparation method, it was referred to L- carnitine method (Starkey et al., 2008) of formulated milk powder and raw materials, which is introduced in AOAC journal. However, there were several difficulties with rapid accurate sample preparation. First, the method of AOAC journal uses L-carnitine-methyl-d3 HCl, isotopically labeled internal standard. However, it was thought that there was difficulty in using this internal standard in the testing & research institute and industrial circles due to high price, restriction on the import of radioactive isotope, and so on. Second, the method presented by the previous study was a very simple method that had sample preparation process where 2 g of sample was taken, and then it was dissolved in water of 500 ml, and PTFE filter treatment was carried out, and then instrumental analysis was made. However, as this doesn t have any deproteinization and fat-free process, there is possibility of having a bad effect due to the accumulation of contamination in the instrument in case of repeated analysis. For the above reason, we aimed at the test method that showed high recovery without using internal standard, and carried out the development of test method by introducing fat-free technology through organic solvent treatment and deproteinization through acid treatment in order to prevent col-

752 Korean J. Food Sci. An., Vol. 34, No. 6 (2014) ml, ph 5.0 = 0.55 ml, ph 6.0 = 0.25 ml, and control = ph 6.8 respectively. Therefore, on the basis of this study, we judged that it was proper to adjust ph to 4.0 in case of infant and toddler formula sample preparation. And according to the test results, it was verified that ph was adjusted to the level of 4.0 in case 0.1 M HCl 1 ml was projected on the basis of sample 0.3 g/final volume 10 ml. Fig. 1. Contents of L-carnitine in the extracted solution by ph adjusting in the range of 3.0 ~ control. Control ph was 7.6 (SRM 1849a), and 6.8 (infant formula sample), respectively. umn and detector from being contaminated. Isoelectric protein precipitation using acid treatment was attempted for deproteinization. Fig. 1 showed the relative response results of L-carnitine detected in the final solution according to each ph after deproteinization treatment. In the test results, infant formula sample didn t show large difference in the relative response of L-carnitine from the ph 3.0 to the control ph 6.8. However, in SRM 1849a, no difference was shown in the response from ph 3.0 to 4.0, but it was observed that L-carnitine content went down to the level of 75% from ph 4.5 or over. In case of SRM 1849a, the amount of 0.1 M HCl projected in order to adjust ph was ph 3.0 = 1.7 ml, ph 3.5 = 1.4 ml, ph 4.0 = 1 ml, ph 4.5 = 0.8 ml, ph 5.0 = 0.6 ml, ph 6.0 = 0.3 ml, and control = ph 7.6 respectively. Besides, in case of randomly selected infant formula sample, the amount of 0.1 M HCl projected in order to adjust ph was ph 3.0 = 1.6 ml, ph 3.5 = 1.3 ml, ph 4.0 = 1 ml, ph 4.5 = 0.7 Optimization for mobile phase To the optimization of selectivity for L-carnitine, the ratio of 0.1% heptafluorobutyric acid in water solution (mobile phase A) to 0.1% heptafluorobutyric acid in methanol solution (mobile phase B) was changed from 0 to 100% in order to establish the optimum mobile phase condition of selected column (Zorbax Eclipse C 8, 4.6 mm 150 mm 5 μm, Agilent). The results were shown in Fig. 2. When the ratio of mobile phase A to B was 90:10, the optimum condition where the specificity of substance subject to analysis was secured and the sensitivity of peak was the highest in the test results. After that time, tests were carried out in the above mobile phase condition. Linearity & range L-carnitine content in infant and toddler formula was approximately 100 mg/kg, and the range of certified value of SRM 1849a was 136±14 mg/kg. In case of completing sample preparation with final volume of 10 ml in comparison with sample of 0.3 g proposed by this study, the range of expected calibration curve was at the level of 3-5 mg/l (ppm). However, linearity was not shown in measuring carnitine standard in case of high-concentration Fig. 2. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) chromatograms when different mobile phases were used for L-carnitine analysis.

Rapid Determination of L-carnitine by Liquid Chromatography Tandem Mass Spectrometry 753 Fig. 3. Comparison of calibration curves for L-carnitine standard solutions; 9 points of 1, 5, 10, 25, 50, 100, 250, 500, and 1000 µg/l (a), 5 points of 50, 100, 250, 500, and 1000 µg/l (b), 5 points of 1, 5, 10, 25, and 50 µg/l (c), respectively. calibration curve in ppm unit. Therefore, the necessity of measurement with lowering calibration curve concentration and diluting final preparation solution came to the front. In order to establish the optimum calibration curve condition, carnitine standard was measured at 9 points within the range of 1-1,000 μg/l (ppb), and the section that showed linearity was observed in the range. The results were shown in Fig. 3. According to the test results, r 2 value was 0.9990 and linearity was shown in the section of 1, 5, 10, 25, and 50 μg/l. And quadratic calibration curve was observed in the section of 50, 100, 250, 500, and 1000 μg/l. Therefore, in this test, we decided on 1-50 μg/l of calibration curve concentration, and decided that final solution was diluted 200 times in conformance with this, and then was used for instrumental analysis. Method validations Detection limit test, infant formula recovery test, and certified reference material SRM 1849a quantitative analysis were carried out in order to verify the validity of developed L-carnitine LC-MS/MS analytical method. The method was validated through comparison of quantitative analysis results with certified value. The test results showed that the limit of detection (LOD) was 0.05 μg/l, and the limit of quantitation (LOQ) was 0.17 μg/l, and method detection limit (MDL) was 0.57 mg/kg. In case of recovery test, recovery was shown to be 93.18-95.64% and relative standard deviation was shown to be 1.93-2.74%. Therefore, the result values were good. Besides, the carnitine content of SRM 1849a was measured to be 127.09 mg/kg and recovery of 93.38% was shown in case of being compared with 136 mg/kg, median of certified value. From the above results, it was possible to judge that instrumental analysis condition and preparation method used in this study was valid. The specific validation factors were shown in Table 2. In this study, the establishment of MS conditions was conducted by following the guidelines for the determination of L-carnitine specified by the European Community (EC) and the Codex Alimentarius Commission (CAC)

754 Korean J. Food Sci. An., Vol. 34, No. 6 (2014) Table 2. Validation factors and monitoring test for L-carnitine in certified reference material (SRM 1849a) and infant formula using liquid chromatography-tandem mass spectrometry analysis Recovery test Tested Value (mg/kg) RSD (%) Recovery (%) SRM 1849a 127.09 ± 1.67 1.31 93.45 ± 1.23 T-1 265.84 ± 3.84 2.74 93.18 ± 1.54 Spiked sample T-2 271.91 ± 3.22 2.53 95.64 ± 1.45 T-3 265.81 ± 2.65 1.93 95.31 ± 2.03 Samples Tested Value (mg/kg) Samples Tested Value (mg/kg) T-1 141.25 T-1 191.28 T-2 111.18 T-2 137.27 T-3 138.77 T-3 130.51 T-4 133.58 T-4 124.96 T-5 104.18 Toddler formula T-5 106.78 Infant formula (milk-based, powder) T-6 100.13 (milk-based, powder) T-6 102.39 T-7 109.25 T-7 114.79 T-8 111.78 T-8 140.29 T-9 130.75 T-9 159.45 T-10 136.84 T-10 143.31 T-11 138.22 T-1 142.03 T-12 149.88 Infant formula T-2 126.45 T-13 139.82 (cereal-based, powder) T-3 117.56 T-14 138.15 T-4 184.02 T-15 129.25 Samples Tested Value (mg/l) T-1 20.89 Infant formula T-2 17.97 (milk-based, liquid) T-3 15.60 r 2 0.9990 Linear Regression y = 296.56x + 320.70 LOD (µg/l) 0.05 Range 1~50 µg/l LOQ (µg/l) 0.17 MDL (mg/kg) 0.57 (Commission decision of 12 August 2002, 2002; Codex guideline, 2007). The precursor ion for L-carnitine corresponded to 162 m/z, the product qualitative ions was 85, and the quantitative ion was 103 m/z, respectively. Under these conditions, by comparison with the standard deviation of the relative response values, the results for SRM 1849a and infant formula samples were within the acceptable range. Monitoring test for infant and toddler formulas A monitoring test was carried out for 32 samples of infant formula and toddler formula with SRM 1849a, international certified reference material. The results of monitoring test were shown in Table 2. According to the results of the monitoring test, in case of powder form product, L-carnitine content was at the level of 100.13-191.28 mg/kg. It was at the level of 15.60-20.89 mg/l, in case of liquid form product. This was at the accurate level in comparison with content indicated on the product. Therefore, it was possible to verify that L-carnitine indication management of infant and toddler formula placed on the Korean market was well accomplished. Quantity corresponding to appropriate sample volume of each food group was 0.3 g for all sample groups and it was quantity corresponding to sample volume included in calibration curve concentration established by the method. LC-MS/ MS chromatogram and mass spectrum for L-carnitine was shown in Fig. 4. The chromatograms and the mass spectrum showed that the standard solution, infant formula and SRM 1849a sample treated by the developed test method and standard solution. Conclusions A method for the determination of L-carnitine in infant and toddler formula was developed by using LC-MS/MS and simple pretreatment. A 0.3 g of infant formula sample was mixed in a 50 ml conical tube with 9 ml water and 1 ml 0.1M HCl to chemical extraction. Then, chloroform was used for removing a lipid fraction. After cen-

Rapid Determination of L-carnitine by Liquid Chromatography Tandem Mass Spectrometry 755 Fig. 4. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) chromatograms of L-carnitine by the total ion current and multiple reaction monitoring (MRM) mode, with relative response ratios; L-carnitine standard solution (a), SRM 1849a (b), and Infant formula sample (c), respectively. trifuged, L-carnitine was separated and quantified using LC-MS/MS with ESI mode. This procedure was applied to small sample weight, ph adjustment, and lipid elimination. Sample pretreatment time and labor were reduced, although the recovery test showed good results for infant formula sample. The precursor ion for L-carnitine was m/ z 162, and product ions were m/z 103 (quantitative) and m/z 85 (qualitative), respectively. The results for spiked recovery test were in the range of 93.18-95.64% with relative standard deviations between 1.93% and 2.74% and the result for certified reference material (SRM 1849a) was within the range of the certificated values. The developed method based on LC-MS/MS in MRM mode, following the described sample preparation, could be an accurate tool that could replace the official methods when time and labor need to be reduced. In addition, it could be expected that a beginner can easily perform the analysis work as the analysis time is short and the low level of proficiency is required for testers. Acknowledgements This paper was supported by a grant (13162 MFDS 016) from Ministry of Food and Drug Safety in 2013 and as part of Konkuk University s research support in 2013. References 1. Andrieux, P., Kilinc, T., Perrin, C., and Campos-Giménez, E. (2008) Simultaneous determination of free carnitine and total choline by liquid chromatography/mass spectrometry in infant formula and health-care products: single-laboratory validation. J. AOAC Int. 91, 777-785. 2. AOAC International (2002) AOAC Guidelines for Single Laboratory Validation of Chemical Methods for Dietary Supplements and Botanicals. Association of Official Analytical Chemists, Gaithersburg, MD, USA. 3. AOAC Official Method 999.14 (2003) Choline in Infant Formula and Milk to the Determination of Choline in Dietary Supplements. Enzymatic colorimetric method, Final Action 2003. 4. Codex guideline (2007) Draft Guidelines for the Design and Implementation of National Regulatory Food Safety Assurance Programs Associated with the Use of Veterinary Drugs in Food Producing Animals. Codex Alimentarius Commission, Rome, Italy. 5. Commission decision of 12 August 2002 (2002) Implementing council directive 96/23/EC concerning the performance of analytical methods and the interpretation of results. Official Journal of the European Communities, Lisbon, Portugal. 6. Gong-Xin, H. and Terry, D. (2000) Improved high-performance liquid chromatographic method for analysis of L-carnitine in pharmaceutical formulations. J. Pharmaceut. Biomed. 23, 315-321. 7. Lovrien, R. E. and Matulis, D. (1997) Selective precipitation of proteins. Curr. Protoc Protein Sci. 4, 1-36. 8. Olpin, S. E. (2005) Fatty acid oxidation defects as a cause of neuromyopathic disease in infants and adults. Clinical Laboratory 51, 289-306. 9. Sowell, J., Fuqua, M., and Wood, T. (2011) Quantification of total and free carnitine in human plasma by hydrophilic interaction liquid chromatography tandem mass spectrometry. J.

756 Korean J. Food Sci. An., Vol. 34, No. 6 (2014) Chromatogr. Sci. 49, 463-468. 10. Starkey, D. E., Denison, J. E., Seipelt, C. T., and Jacobs, W. A. (2008) Single-laboratory validation of a liquid chromatographic/tandem mass spectrometric method for the determination of free and total carnitine in infant formula and raw ingredient. J. AOAC Int. 91, 130-142. 11. Steiber, A., Kerner, J., and Hoppel, C. L. (2004) Carnitine: a nutritional, biosynthetic, and functional perspective. Mol. Aspects. Med. 25, 455-473. 12. Sullivan, D. M. and Carpenter, D. E. (1993) Methods of analysis for nutrition Labeling: Chapter 5 Lipid Analysis. Arlington, VA, USA, AOAC International 85-103. 13. Vogt, C. and Seim, H. (1996) HPLC and capillary electrophoresis in carnitine analysis. Carnitine: pathobiochemical basics and clinical applications: Carnitine symposium, Carnitine: pathobiochemical basics and clinical applications (pp. 85-96). Ponte Press, Bochum. (Received 2014.8.21/Accepted 2014.9.28)