Integra. Titan Total Shoulder System FRACTURE SURGICAL TECHNIQUE

Similar documents
Integra. Titan Modular Shoulder System, 2.5

SURGICAL TECHNIQUE. Global Fx SHOULDER FRACTURE SYSTEM

The Bio-Modular Choice Shoulder System,

SURGICAL TECHNIQUE. Global Fx SHOULDER FRACTURE SYSTEM

SURGICAL TECHNIQUE. Global Fx SHOULDER FRACTURE SYSTEM

Integra. Modular Radial Head System SURGICAL TECHNIQUE

Design Rationale. The Design

Integra. Silicone PIP Implant SURGICAL TECHNIQUE

TORNIER BIO-RSA. Bony Increased Offset - Reversed Shoulder Arthroplasty SURGICAL TECHNIQUE

Integra. Proximal Humeral Fracture Plate System SURGICAL TECHNIQUE

3. PATIENT POSITIONING & FRACTURE REDUCTION 3 8. DISTAL GUIDED LOCKING FOR PROXIMAL NAIL PROXIMAL LOCKING FOR LONG NAIL 13

URSA HEMI-SHOULDER ARTHROPLASTY B I O T E K

Integra. Modular Radial Head System SURGICAL TECHNIQUE

Integra. Titan Modular Shoulder System, 2.5 SURGICAL TECHNIQUE

Integra. Titan Reverse Shoulder System SURGICAL TECHNIQUE

Integra. DigiFuse Cannulated Intramedullary Fusion System SURGICAL TECHNIQUE

Technique. Aequalis Resurfacing Humeral Head

This surgical technique describes how to perform an anatomic total shoulder arthroplasty implanting a short stem.

Integra. Titan Reverse Shoulder System SURGICAL TECHNIQUE

Surgical Technique. Proximal Humerus Locking Plate

System. Humeral Nail. Surgical Technique

Solar Humeral Fracture System. Surgical Protocol

ANATOMICAL. REDEFINED.

U2 PSA. Revision Knee. Surgical Protocol

Aequalis Press-Fit. Shoulder Prosthesis. Surgical Technique

AcUMEDr. Locking Proximal Humeral Plate. PoLARUSr PHPt

TABLE OF CONTENTS SURGICAL TECHNIQUE 1 POST-OPERATIVE REHABILITATION 18. pages 1 RADIOLOGICAL ASSESSMENT 1 2 PATIENT POSITIONING 1

DESIGN RATIONALE AND SURGICAL TECHNIQUE

Anatomical Shoulder Fracture. Surgical Technique

System Overview 3. Anatomic Sizing And Design Features 4. Instrumentation 6. Indications And Contraindications 7. Surgical Technique 8

S H O U L D E R Solutions by Tornier. BIO-RSA TM ANGled SURGICAL TECHNIQUE. BIO-RSA Angled. surgical technique

Conventus CAGE PH Surgical Techniques

Surgical. Technique. Aequalis Press-Fit. Shoulder Prosthesis.

SURGICAL TECHNIQUE GUIDE

Surgical Technique Guide PANTERA. Proximal Humerus Fracture Fixation Plate System

Comprehensive Fracture System. Surgical Technique

This publication is not intended for distribution in the USA. PRODUCT RATIONALE & SURGICAL TECHNIQUE

S H O U L D E R Solutions by Tornier. Aequalistm. Pyrocarbon Humeral Head. surgical technique

ANATOMIC SHOULDER ARTHROPLASTY

SURGICAL TECHNIQUE DUAL-PLATFORM SHOULDER ARTHROPLASTY.

Modular Ulnar Head surgical technique. Transforming Extremities

SURGICAL TECHNIQUE. Alpine Cementless Hip Stem

ZMR Over-the-Junction Instruments for Revision Hip Arthroplasty. Surgical Technique IMAGE TO COME

the shape, the size, the fit Ascension Modular Radial Head

Clinical Evaluation Surgical Technique

REVERSE SHOULDER ARTHROPLASTY

Encina Taper Stem. Stinson Orthopedics Inc. 303 Twin Dolphin Drive, Suite 600 Redwood City, CA

TABLE OF CONTENTS. 2 (8144 Rev 2)

Index. B Backslap technique depth assessment, 82, 83 diaphysis distal trocar, 82 83

Surgical Technique. CONQUEST FN Femoral Neck Fracture System

TORNIER AFFINITI EH 2. Extended Humeral Head SURGICAL TECHNIQUE

Comprehensive Fracture System. Surgical Technique

TEM TED S GRA INTE SHOULDER SY

Surgical Technique. Clavicle Locking Plate

CAUTION: Ceramic liners are not approved for use in the United States.

SURGICAL TECHNIQUE CEMENTED & PRESS-FIT UNIFIED INSTRUMENTATION INTRAOPERATIVE FLEXIBILITY PROVEN BIOMECHANICS

COMPLETE, CONVERTIBLE, INNOVATIVE. Surgical Technique REVERSE SHOULDER ARTHROPLASY

Operative Technique Resurfacing Humeral Head

Taperloc Complete Hip System. Surgical Technique

RESURFACING HUMERAL HEAD IMPLANT TRAUMA & EXTREMITIES GROUP

TORNIER SIMPLICITI. Shoulder System SURGICAL TECHNIQUE

Humeral SuturePlate. Surgical Technique

Technique Guide. Epoca Revision Instrument Set. For extraction and revision of Epoca shoulder implants.

D Degenerative joint disease, rotator cuff deficiency with, 149 Deltopectoral approach component removal with, 128

Zimmer Trabecular Metal Ankle Interpositional Spacer and Trabecular Metal Ankle Fusion Spacer

SHOULDER ARTHROPLASTY SYSTEM

Solutions by Tornier. surgical technique

Technique Guide. 3.5 mm LCP Periarticular Proximal Humerus Plate. Part of the Synthes locking compression plate (LCP) system.

TM HUMELOCK II. Cementless. Hemi SURGICAL TECHNIQUE

Open reduction; plate fixation 1 Principles

Bone Preservation Stem

Bigliani/Flatow The Complete Shoulder Solution TSA

EXACTECH EXTREMITIES. Operative Technique. Preserve Stem. Surgeon focused. Patient driven. TM

Progeny Hip Stem. Surgical Protocol and Product Specifications

THE NATURAL FIT. Surgical Technique. Hip Knee Spine Navigation

Cementless Tapered Femoral Stem Surgical technique

Arcos Interlocking Distal Stem. Surgical Technique Addendum to the Arcos Modular Femoral Revision System

Operative Technique Resurfacing Humeral Head

BICEPTOR Tenodesis System

OPTIONAL/ADDITIONAL INSTRUMENTS

Operative Technique CTA Head

TM HUMELOCK II. Cemented. Hemi / Trauma. Total / Primary SURGICAL TECHNIQUE

Zimmer Periarticular Proximal Humeral Locking Plate

Bipolar Radial Head System

Revision. Hip Stem. Surgical Protocol

Table of contents. Introduction... 3 Indications... 3 Contraindications... 3 TRIGEN Humeral Nail Specifications... 6

FOR INTERNAL USE ONLY. Shoulder System. Pocket Reference Guide

Cementless Tapered Femoral Stem Surgical technique

Talar Dome System Surgical Technique

Biomet Large Cannulated Screw System

Salto Talaris Total Ankle Prosthesis

Anatomic and Reverse Shoulder. Surgical Technique

TORNIER AEQUALIS REVERSED FX. Shoulder System SURGICAL TECHNIQUE

Surgical. Technique. AEQUALIS Spherical Base Glenoid. Shoulder Prosthesis.

HUMELOCK II. Cemented + Graft ANATOMICAL and REVERSIBLE if REVISION SURGICAL TECHNIQUE

Turon Modular Shoulder System. Surgical Technique

Zimmer NexGen MIS Tibial Component. Cemented Surgical Technique IMAGE TO COME

Technique Guide. Primary Stemless Shoulder System

SURGICAL TECHNIQUE GUIDE

Transcription:

Integra Titan Total Shoulder System FRACTURE SURGICAL TECHNIQUE

Table of Contents Design Rationale...02 Indications/Contraindication/Warnings/Precautions...03 Surgical Technique... 04 Step 1: Preoperative Templating & Patient Positioning...05 Step 2: Exposure...05 Step 3: Head Excision and Sizing... 06 Step 4: Humeral Canal Preparation... 06 Step 5: Distal Trial Stem and Proximal Trial Body Insertion... 06 Step 6: Head Trialing and Restoring Humeral Height...07 Step 7: Trial Reduction...07 Step 8: Diaphysis Preparation for Tuberosity Repair...08 Step 9: Prosthesis Assembly and Implantation... 08 Step 10: Bone Grafting and Tuberosity Repair... 09 Step 11: Closure... 09 Revision Procedure... 10 Long Stem Option... 10 Essential Product Information... 11 Instrumentation...13 Implant Catalog Numbers & Dimensions... 19

Design Rationale Titan Proximal Humerus Fracture Solution The Titan Total Shoulder System provides a unique way to address what may be seen as a difficult procedure. Titan s modular stem design allows the surgeon to mix component sizes to best fit patient anatomy. The ability to press-fit the hemiarthroplasty humeral prosthesis to address proximal humerus fractures gives an advantage of intraoperative height adjustment without need for jigs or the use of cement. Concentric Head Eccentric Head Interchangeable proximal bodies and distal stems to accommodate varying patient anatomy. Multiple fixation options (press-fit vs. cemented) to address varying bony quality. Bone impaction humeral preparation technique to preserve bone stock. Well-fixed stem provides an intraoperative building platform and a pathway for revision. Heads 26 Eccentric & Concentric Humeral Heads in Various Heights Optimal osteotomy coverage and soft tissue balancing Bodies Textured Modular Bodies in 3 Heights Allow for intraoperative height adjustment Smaller proximal body size promotes tuberosity consolidation and increased union opportunity Addresses varying patient anatomy Promotes initial and long-term bone fixation Polished Suture Holes and Groove For added bone and soft tissue fixation May reduce suture abrasion Height Lines To help simplify replication of trial to definitive prosthesis height placement Stems Press-Fit Stem Option No need to remove cement in case of revision Bone impaction humeral preparation to preserve bone stock 12 splines on stem contribute to enhanced press fit and anti-rotation for a well fixed stem Cemented Stem and Cemented Long Stem Options to Address Varying Bone Quality Smooth, fluted stem allows for optimal cement fixation and rotational control 5 stem diameters ranging from 6-14 mm to address varying humeral sizes Long Stems in 8, 10 and 12mm diameter options; all available in 125mm and 165mm lengths Tapered, polished distal stem for ease of insertion Fracture Body Cemented Stem Body Screw Press-Fit Stem Titan Total Shoulder System was developed in collaboration with: Joseph Abboud, M.D. Phillip Duke, MB.BS, FRACS, FA(ORTH)A William Geissler, M.D. Sanford Kunkel, M.D. Anand Murthi, M.D. Matthew Ramsey, M.D. Mark Ross, MB.BS.FRACS(ORTH) 2

Indications For Use Total Shoulder Arthroplasty or Hemiarthroplasty is indicated for: Severely painful and/or disabled joint resulting from osteoarthritis, traumatic arthritis or rheumatoid arthritis. Fracture-dislocations of the proximal humerus where the articular surface is severely comminuted, separated from its blood supply or where the surgeon s experience indicates that alternative methods of treatment are unsatisfactory. Other difficult clinical problems where shoulder arthrodesis or resection arthroplasty are not acceptable (e.g. revision of a failed primary component). Shoulder Hemiarthroplasty is also indicated for: Ununited humeral head fractures. Avascular necrosis of the humeral head. Rotator cuff arthropathy. Deformity and/or limited motion. The humeral component is intended for cemented or un-cemented use. The glenoid component is intended for cemented use only. Contraindications The following conditions are contraindications for total shoulder arthroplasty and hemiarthroplasty: Active local or systemic infection. Inadequate bone stock in the proximal humerus or glenoid fossa for supporting the components. Poor bone quality, such as osteoporosis, where there could be considerable migration of the prosthesis and/or a chance of fracture of the humerus or glenoid. Absent, irreparable or nonfunctional rotator cuff or other essential muscles. Pregnancy. Muscular, neurologic, or vascular deficiencies that compromise the affected extremity. Known metal allergies. Warnings The use of a glenoid prosthesis in patients with cuff tear arthropathy could increase the risk of glenoid component loosening due to non-anatomic loading conditions. The following conditions tend to adversely affect shoulder replacement implants; Excessive patient weight High levels of patient activity Likelihood of falls Poor bone stock Metabolic disorders Disabilities of other joints Precautions Do not reuse this device. Reuse of this product may result in infection or other systemic complication that may affect the patient s overall health. Additionally, the reuse of this product could adversely affect function of the device. Any implant that has been damaged, mishandled, or removed from the sterile field may have surface damage that could result in implant fracture and/or particulate and should be discarded. The MR environment presents risks to patients with metal implants. Review of the available literature documents that metal implants may heat resulting in tissue damage and may migrate out of position. They may also cause artifact affecting image quality. Physicians should take these risks into consideration when recommending MRI imaging for patients with metal implants. Note: The Titan Reverse Shoulder System and Titan Total Shoulder System have not been evaluated for safety and compatibility in the MR environment. Neither the Titan Reverse Shoulder System nor the Titan Total Shoulder System has been tested for heating or migration in the MR environment. 3

Surgical Technique As the manufacturer of this device, Integra does not practice medicine and does not recommend this or any other surgical technique for use on a specific patient. The surgeon who performs any implant procedure is responsible for determining and using the appropriate techniques for implanting the device in each patient. Proper surgical procedures and techniques are the responsibility of the medical professional. Individual surgeon evaluation of the surgical technique should be performed based on his or her personal medical training and experience. This essential product information does not include all of the information necessary for selection and use of a device. Please see full labeling on package insert for all necessary information. The goal of hemiarthroplasty for fracture is to replace the humeral head with a prosthetic component, reconstruct the rotator cuff, and repair the tuberosities by securing to both the humeral shaft and the prosthesis. Introduction A hemiarthroplasty is indicated when salvage of the native humeral head is not possible. This is the case in most head-splitting fractures of the humeral head, and in impression fractures involving more than 40% of the head. In a typical or classic four-part fracture, the humeral head fragment is separate from the shaft and both tuberosities, and is dislocated out of the glenoid. Figure 1. The greater and lesser tuberosities are separated from the head fragment, and may be separated from each other. The head is devoid of all soft-tissue attachment, creating a high probability of avascular necrosis. For this reason, a hemiarthroplasty is typically used in older patients. In younger patients, especially those with a valgus impacted pattern, internal fixation may be preferred. Description Displaced 4-Part Fracture Of Proximal Humerus The pathophysiology of displaced 4-part fractures involves each muscle or muscle group pulling fragments in various directions. Figure 2. The diaphysis (1) is drawn medially by the pectoralis major and latissimus dorsi muscles and is separated from the epiphysis at the surgical neck. The lesser tuberosity (2) is retracted anteromedially by the subscapularis. The greater tuberosity (3) is retracted medially, superiorly and posteriorly by the supraspinatus, infraspiratus and teres minor. The tuberosities may remain intact or be fragmented, and may be separated or remain in continuity with one another (impacted type). The humeral articular surface (4) is no longer in contact with the glenoid. It is separated from the tuberosities and may undergo varus or valgus displacement, usually resulting in devascularization. It may present an impacted fracture or a displaced fracture. 1 2 3 4 2 1 4

Step 1 Preoperative Templating and Patient Positioning 3 Preoperative evaluation of the humerus using the modular total shoulder x-ray templates helps determine the size of the prosthesis and proper height restoration. Hemiarthroplasty for proximal humerus fracture can be performed using general anesthesia, regional anesthesia (i.e., interscalene block), or a combination. Place the patient in beach chair position, Figure 3. This position would have the patient supine with the hips flexed approximately 30, knees bent approximately 30 and back elevated approximately 30. Specialized headrests, such as the Mayfield or the McConnell, arm mounts or operating tables with breakaway side panels can facilitate further access to the top and back of the shoulder. Step 2 Exposure A deltopectoral approach is used to provide exposure to the anterior aspect of the glenohumeral joint, the upper humeral shaft and the humeral head. The initial incision line runs from the mid-clavicle, over the top of the coracoid and extends in a straight line down the anterior aspect of the arm, Figure 4. It should follow the path of the cephalic vein along the interval between the deltoid and the pectoralis major. The length of the initial incision along this line can vary, depending on the exposure needed to provide adequate access and visualization of the joint, and is determined by patient body habitus. Once the initial incision is made, expose, incise and release the fascia. Locate the cephalic vein at the deltopectoral interval. Separate the deltoid and pectoralis major muscles so that the deltoid muscle is completely free from its origin to its insertion, especially along its deep surface. Abduct and externally rotate the arm. Gently retract laterally the cephalic vein along with the deltoid muscle. 4 5 Incise the clavipectoral fascia lateral to expose the conjoined tendon. If needed, release the upper 25% of the pectoralis major tendon from its insertion on the humerus, using an electrocautery cutting blade. Figure 5. Place a Hohmann retractor over the top of the humeral head, pulling the upper part of the deltoid posteriorly. Check that the rotator cuff tendons are intact. Introduce self-retaining Weitlander or Kobel retractors underneath the conjoined tendon and underneath the middle deltoid. It is important to always save or preserve the coracoacromial ligament. 6 Isolate, clamp and ligate or coagulate the anterior humeral circumflex vessels lying across the anterior/inferior third of the subscapularis tendon. In Fracture cases it is important to be aware of the musculocutaneous nerve, which penetrates the coracobrachialis muscle 3-5 cm distally from the coracoid. The nerve may not be palpable within the surgical field, but note its proximity to the conjoined tendon. Figure 6. 7 Introduce a Hohmann retractor and carefully retract the Axillary nerve along with the latissimus dorsi tendon. This is especially important as it will protect the axillary nerve, define and expose the inferior capsule. Locate the biceps tendon, it can be used to identify the area between the lesser and greater tuberosity. Using scissors dissect the sheath of the biceps tendon and divide the transverse humeral ligament. Figure 7. 5

Step 2 Exposure (continued) 8 Release the Biceps tendon from the bicipital groove and along the rotator interval down to its glenoid attachment. Resect the long head of the biceps at the origin of the superior glenoid at the transverse humeral ligament. Step 3 Head Excision and Sizing With the tuberosities retracted out of the way via stay sutures or retractors, use a towel clip or bone hook to remove the humeral head and all fractured pieces. Figure 8. Measure the removed humeral head on the Head Sizing Gauge, Figure 9. Once size has been determined harvest any cancellous bone out of the humeral head you may need for grafting later in the procedure. 9 Step 4 Humeral Canal Preparation Attach the 6mm Humeral Stem Trial to the Stem Trial Handle. With the arm in adduction, external rotation and extension begin sequential trialing starting with the 6mm Humeral Stem Trial. Follow the path created through the intramedullary canal and increase the Stem Trial diameter in 1mm increments until the Stem Trial fits securely in the humerus. Figure 10. Note the final Humeral Stem Trial diameter. This will determine the size of the Humeral Stem implant. Reduce the tuberosities around the Stem Trial Handle. Using the laser lines, estimate the body height needed. Step 5 Distal Trial Stem and Body Insertion Attach the selected Stem Trial to the standard size Fracture Body Trial. Attach the Body/ Stem Trial construct to the Fracture Trial Inserter/Extractor. 10 11 Affix the Version Rod to the Fracture Trial Inserter/Extractor to ensure proper version. The Version Rod is aligned parallel with the patient s forearm and initially sets the trial in 30 of retroversion. Using the Slotted Mallet, carefully drive the Body/Stem Trial into the proximal humerus so that the Body/Stem Trial is in line with the long axis. Seat the Body/ Stem Trial until the desired fit is achieved, Figure 11. 6

Step 5 Distal Trial Stem and Body Insertion (continued) The Body/Stem Trial should be positioned at the correct height to preserve the anatomic reconstruction of the tuberosities. If the Fracture Body Trial is too short, the prosthesis will not allow space for the anatomic reconstruction of the tuberosities. Figure 12. If this happens remove the Standard Fracture Body Trial and replace with the Large Fracture Body Trial. This will increase the overall prosthesis height and allow for more surface area and proper reconstruction of the tuberosities. Figure 13. If the overall prosthesis is too proud with the Standard Fracture Body Trial, replace it with the Small Fracture Body Trial. Placing the prosthesis at the proper level will allow space for anatomic reconstruction of the tuberosities. If more height is desired after increasing to a Large Fracture Body Trial, increasing stem diameter will result in a higher seated prosthesis. A slight overlap of the tuberosities on the prosthesis is desirable. 12 Incorrect Height 13 Remove the Inserter/Extractor. STEP 6: Head Trialing and Restoring Humeral Height Place the Taper Adapter onto the Fracture Body Trial using the Taper Adapter Shaft and attach the previously selected size Head Trial to the fracture body, Figure 14. This size was selected after removal and sizing of the humeral head (Table below shows head options). WIDTH HEIGHT 38 14* 40 15* 42 16 44 16, 19 46 14, 17, 20 48 15, 18, 21 50 19, 22 52 20 Correct Height 14 15 *Only Eccentric Head Option STEP 7: Trial Reduction Note the height etchings on the side of the Fracture Body Trial to replicate height of final implant. Figure 15. Perform a trial reduction and range of motion test. Ensure that the humeral head remains in the glenoid fossa and does not ride too high. Also ensure there is free motion with no undue tightness. Adjust Fracture Body Trial height or Head Trial if there is any height or soft tissue balance issues. Figure 16. 16 Reduce the tuberosities to ensure they will fit around the prosthesis and can be attached to one another. A towel clip or reduction forcep can be utilized to hold the tuberosities around the prosthesis. Check soft tissue tensioning by performing a gentle range of motion test. 7

Step 8 Diaphysis Preparation for Tuberosity Repair 17 Drill two suture holes, one on each side of the bicipital groove, into the humeral shaft to assist in repair of the tuberosities. Place two heavy non-absorbable sutures through the drill holes before proceeding with prosthesis implantation. Figure 17. Step 9 Prosthesis Assembly and Implantation Body Stem Assembly Select and remove from their packaging the final sized Fracture Body and Humeral Stem that corresponds to the trials. Seat and secure the Fracture Body implant onto the Stem Impaction Stand. Place the Humeral Stem implant onto the Humeral Body with finger pressure. Place the Stem Impactor over the tip of the humeral stem and engage the tapers with a few mallet strikes. Figure 18A. Remove the final Fracture Body/Stem implant construct from the Stem Impaction Stand and place the implant into the Head Impaction Stand with the appropriate size Head Impaction Stand Insert. The Head Impaction Stand should match the size of your Body Trial (SML, STD, LRG) Figure 18B. Tighten the knob on the side of Head Impaction Stand to secure the implant. Remove the Humeral Body Screw from its packaging and insert into the Humeral Body with the Driver Handle, Torque Limiter and 1/8 Hex Driver. Tighten the screw until the torque limiter clicks. Figure 18B. Cemented Stem Thoroughly irrigate the medullary canal to remove debris. Use either a small piece of cancellous bone or utilize a cement restrictor and place 1-2 cm below distal stem to prevent cement from extruding to the elbow. Use either a medium or high viscosity cement, place cement down the humeral canal using finger pressure. Figure 19. Cemented Stem options are available in 2 mm increments (6-14 mm). A definitive prosthesis sized 1-2 mm smaller than Stem Trial used should be selected to allow for adequate cement mantle. Attach the final prosthesis to the Fracture Implant Inserter/ Extractor. Affix the Version Rod to the Inserter/Extractor to ensure proper version and use hand pressure to insert prosthesis. The Version Rod is aligned parallel with the patient s forearm and sets the prosthesis in 30 of retroversion. Figure 20. Note the etchings on the side of the Fracture Body to replicate humeral height from the trial reduction. Remove any excessive cement from around the fracture body and suture holes. Allow the cement to dry before proceeding. Press-fit Stem Attach the Fracture Implant Inserter/Extractor to the final prosthesis. Attach the Version Rod to Inserter/Extractor to ensure proper version and use light taps with a mallet to seat the implant. The Version Rod is aligned parallel with the patient s forearm and initially sets the prosthesis in 30 of retroversion. FIGURE 20. Note the etchings on the side of fracture body; they should replicate humeral height from the trial reduction. 18A 19 20 18B 8

Step 9 Prosthesis Assembly and Implantation (continued) 21 Humeral Head Re-trialing of the humeral head is now possible but not required. Once humeral head is selected, place it on the trunion of the stem. Impact the implant using the Head Impactor with a few strikes from a mallet, Figure 21. Step 10 Bone Grafting and Tuberosity Repair Utilizing the bone graft removed earlier from the humeral head, graft the area around the humeral shaft and Fracture Body. Figure 22. Place two heavy non-absorbable sutures through each of the holes on the medial side of the prosthesis. Figure 23. Place the arm in neutral position and reduce the greater tuberosity to its anatomical position. Take one of the sutures in the superior hole and wrap it around the greater tuberosity superiorly and secure it down. Figure 24. Repeat using one of the inferior sutures to wrap around inferiorly and secure the greater tuberosity. Figure 25. Take the remaining two sutures and place one superiorly and one inferiorly into the subsacpularis near the insertion into the lesser tuberosity. The opposite ends of the sutures will wrap around the implant and greater tuberosity which will allow the sutures to reduce and secure the lesser tuberosity. Figure 26. Use the sutures in the humeral shaft to tension the tuberosities. Place one suture anteriorly from the subscapularis to the supraspinatus, and the second suture posteriorly from the supraspinatus to the infraspinatus, to secure tuberosities to the humeral shaft. Figure 27. The biceps tendon can now be relocated into the bicipital groove and a biceps tenodeses performed using a modified Kessler stitch into the supraspinatus. 22 23 Impact in the direction of the trunion axis Note The above tuberosity repair technique is modeled after Dr. Pascal Boileau s published cerclage technique.* 24 Step 11 Closure Thoroughly irrigate the wound with antibiotic solution. If a regional anesthetic is not used then infiltrate the soft tissue with a local anesthetic that will last six to eight hours. A wound drainage system is recommended to prevent formations of postoperative hematoma. The wound may be closed according to surgeon preference. 25 *Boileau P, Walch G, Krishnan S. Tuberosity Osteosynthesis and Hemiarthroplasty for Four-Part Fractures of the Proximal Humerus. Techniques in Shoulder and Elbow Surgery 2000; 1(2): 96-109. 9

Step 11 Closure (continued) 26 Careful attention to wound closure will result in a cosmetically acceptable incision. After the dressing and shoulder immobilizer are in place, the use of a cold wrap is recommended. The combination of regional anesthetic or local anesthetic and the immediate cooling seems to decrease the amount of postoperative pain. Revision Procedure Removal of the humeral head and/or proximal humeral body during revision surgery can be achieved without disturbing a well-fixed distal stem. Removing the Humeral Head The Humeral Head can be removed using the Head Extractor. Place the two prongs of the Extractor between the Humeral Head and the osteotomy surface so that the prongs will advance in each side of the linking component, Figure 28. Lift the head off the proximal humeral body taper by impacting the end of the Extractor with the Slotted Mallet. Removing the Proximal Humeral Body The proximal humeral body can be removed using the Body Separator. Disengage the locking screw and remove using the 1/8 Hexdriver and Driver Handle. Thread the Body Separator into proximal humeral body. The pre-designed gap between the tines of the Body Separator will disengage the morse taper between the Humeral Body and the Humeral Stem without disruption to a well-fixed Humeral Stem. Remove the Humeral Body that is threaded to the Body Separator. Figure 29. 27 28 Long Stem Option The surgical technique for implanting a Titan Long Stem differs slightly from the standard length stems. Attach the T-Handle to the Starter Awl and create a 6mm pilot hole the humerus. Continue progressively reaming using cylindrical reamers of increasing diameter to 8, 10, or 12mm in either the 125mm or 165mm stem length options. The canal is reamed until cortical chatter is present and inserted to the depth of the laser mark associated with the desired height of humeral body. It is important to prepare the medullary canal over its total length. The final reamer used will correlate to the proper trial stem selected. The reamer, trial, and implant are line to line; minimizing cement to the stem flutes and within the surrounding trabecular bone. If a greater cement mantle is desired, choose an long stem implant diameter smaller than the reamer and trial stem diameter used for preparation. 29 The Body Trials from the Total Shoulder System Humeral Tray 1 Base can be used with the Trial Cemented Stems to determine proper prosthesis height. The Definitive Stem Primary Body Trials can be used with the definitive long stem implants once cemented in place to reassess desired humeral head height. Notes The long stems are for cemented use only. The long reamers are a special order item and do not come with the standard TSS and RSS instrumentation set. 10

Essential Product Information Indications For Use Total Shoulder Arthroplasty or Hemiarthroplasty is indicated for: Severely painful and/or disabled joint resulting from osteoarthritis, traumatic arthritis or rheumatoid arthritis. Fracture-dislocations of the proximal humerus where the articular surface is severely comminuted, separated from its blood supply or where the surgeon s experience indicates that alternative methods of treatment are unsatisfactory. Other difficult clinical problems where shoulder arthrodesis or resection arthroplasty are not acceptable (e.g. revision of a failed primary component). Shoulder Hemiarthroplasty is also indicated for: Ununited humeral head fractures. Avascular necrosis of the humeral head. Rotator cuff arthropathy. Deformity and/or limited motion. The humeral component is intended for cemented or un-cemented use. The glenoid component is intended for cemented use only. Contraindications The following conditions are contraindications for total shoulder arthroplasty and hemiarthroplasty: Active local or systemic infection. Inadequate bone stock in the proximal humerus or glenoid fossa for supporting the components. Poor bone quality, such as osteoporosis, where there could be considerable migration of the prosthesis and/or a chance of fracture of the humerus or glenoid. Absent, irreparable or nonfunctional rotator cuff or other essential muscles. Pregnancy. Muscular, neurologic, or vascular deficiencies that compromise the affected extremity. Known metal allergies. Warnings The use of a glenoid prosthesis in patients with cuff tear arthropathy could increase the risk of glenoid component loosening due to non-anatomic loading conditions. The following conditions tend to adversely affect shoulder replacement implants; Excessive patient weight High levels of patient activity Likelihood of falls Poor bone stock Metabolic disorders Disabilities of other joints Precautions Do not reuse this device. Reuse of this product may result in infection or other systemic complication that may affect the patient s overall health. Additionally, the reuse of this product could adversely affect function of the device. Any implant that has been damaged, mishandled, or removed from the sterile field may have surface damage that could result in implant fracture and/or particulate and should be discarded. The MR environment presents risks to patients with metal implants. Review of the available literature documents that metal implants may heat resulting in tissue damage and may migrate out of position. They may also cause artifact affecting image quality. Physicians should take these risks into consideration when recommending MRI imaging for patients with metal implants. Note: The Titan Reverse Shoulder System and Titan Total Shoulder System have not been evaluated for safety and compatibility in the MR environment. Neither the Titan Reverse Shoulder System nor the Titan Total Shoulder System has been tested for heating or migration in the MR environment. Sterility This implant has been sterilized by gamma radiation and is sterile in the unopened, undamaged package. If either the implant or the package appears damaged or has been opened, or if sterility is questioned for any reason, the implant should not be used. Do not resterilize this product. 11

Adverse Events Potential adverse events include early or late postoperative infection, allergic reaction, intraoperative or postoperative bone fracture and/or postoperative pain. Intraoperative bone perforation or fracture may occur, particularly in the presence of poor bone stock caused by osteoporosis, bone defects from previous surgery, bone resorption, or while inserting the device. Loosening or migration of the implants can occur due to loss of fixation, trauma, malalignment, bone resorption, and/or excessive activity. Surgical intervention may be required to treat adverse effects. MDR Reporting Reminder: Medical device manufacturers and users are required by law and regulation to report serious injuries and death. Product Information Disclosure Integra has exercised reasonable care in the selection of materials and the manufacture of these products. Integra excludes all warranties, whether expressed or implied, including but not limited to, any implied warranties of merchant ability or fitness for a particular purpose. Integra shall not be liable for any incidental or consequential loss, damage, or expense, directly or indirectly arising from use of this product. Integra neither assumes nor authorizes any person to assume for it any other or additional liability or responsibility in connection with these products. Surgical Procedure A Surgical Technique brochure is available which outlines the basic procedure for device implantation and use of the specialized surgical instrumentation. It is the responsibility of the surgeon to be familiar with the procedure before use of these products. Each surgeon must evaluate the appropriateness of the surgical technique used based on personal medical training and experience. Meticulous preparation of the implant site and selection of the proper size implant increase the potential for successful reconstruction. A complete set of instruments for each type of implant is available to aid bone preparation and reduce the operative time. It is suggested that the proper size implant be removed from its sterile package only after the implant site has been prepared and properly sized. Training Surgeons may obtain training from a qualified instructor prior to implanting the Titan Total Shoulder System to ensure thorough understanding of the implantation techniques and the instrumentation. 12

Instrumentation CEMENTED LONG STEM BASE 2 1 3 1 Reamers 2 Slap Hammer 3 Adapters Catalog No. Description QTY RMR-0950-025-08125 Reamer Cemented Long Stem, 8mm x 125mm 1 RMR-0950-025-10125 Reamer Cemented Long Stem, 10mm x 125mm 1 RMR-0950-025-12125 Reamer Cemented Long Stem, 12mm x 125mm 1 RMR-0950-025-08165 Reamer Cemented Long Stem, 8mm x 165mm 1 RMR-0950-025-10165 Reamer Cemented Long Stem, 10mm x 165mm 1 RMR-0950-025-12165 Reamer Cemented Long Stem, 12mm x 165mm 1 ADA-0950-040-501 Trial Adaptor 1 ADA-0950-040-502 Stem Adaptor 1 SLP-1002-519 Slap Adaptor 1 13

CEMENTED LONG STEM INSERT 2 1 This area to remain empty during sterilization 1 Trial Cemented Long Stems 2 Definitive Stem Primary Body Trials Catalog No. Description QTY TRL-0950-025-08125 Trial Cemented Long Stem, 8mm x 125mm 1 TRL-0950-025-10125 Trial Cemented Long Stem, 10mm x 125mm 1 TRL-0950-025-12125 Trial Cemented Long Stem, 12mm x 125mm 1 TRL-0950-025-18165 Trial Cemented Long Stem, 8mm x 165mm 1 TRL-0950-025-10165 Trial Cemented Long Stem, 10mm x 165mm 1 TRL-0950-025-12165 Trial Cemented Long Stem, 12mm x 165mm 1 TRL-0920-120-08STD Definitive Stem Primary Body Trial - 08 Std 1 TRL-0920-120-10SML Definitive Stem Primary Body Trial - 10 Sml 1 TRL-0920-120-10STD Definitive Stem Primary Body Trial - 10 Std 1 TRL-0920-120-10LRG Definitive Stem Primary Body Trial - 10 Lrg 1 TRL-0920-120-12STD Definitive Stem Primary Body Trial - 12 Std 1 TRL-0920-120-14SML Definitive Stem Primary Body Trial - 14 Sml 1 TRL-0920-120-14STD Definitive Stem Primary Body Trial - 14 Std 1 TRL-0920-120-14LRG Definitive Stem Primary Body Trial - 14 Lrg 1 TRL-0950-120-08SML Definitive Stem Primary Body Trial - 08 Sml 1 TRL-0950-120-08STD Definitive Stem Primary Body Trial - 08 Std 1 TRL-0950-120-08LRG Definitive Stem Primary Body Trial - 08 Lrg 1 14

Instrumentation HUMERAL TRAY 1: INSERT 2 1 4 3 8 6 5 7 9 This area to remain empty during sterilization 1 Head Resection Guide 2 Starter Awl 3 T-Handle 4 Version Rods 5 Pin Puller 6 Fixation Pins 7 Cutting Templates & Handle 8 Cutting Depth Gauge 9 Head Sizing Gauge Catalog No. Description QTY SET189-A001 Head Cutting Guide 1 AWL-0920-042-001 Starter Awl 1 G108352_B T-Handle w/lg AO 1 SET189-D007 Version Rod 2 3020 Pin Puller 1 PIN-0920-051-001 Fixation Pin 3 TMP-0920-040-001R Head Cutting Template, Right 1 TMP-0920-040-001L Head Cutting Template, Left 1 ROD-0920-040-002 Head Cutting Template, Handle 1 GAU-0920-058-001 Head Cutting Depth Gauge 1 HSG-0920-041-001 Head Sizing Gauge, 38-46 1 HSG-0920-041-002 Head Sizing Gauge, 48-52 1 15

HUMERAL TRAY 1: BASE 1 2 6 5 4 3 8 7 9 1 Stem Trial Handles 2 Fracture Trial Inserter/Extractor 3 Body Trials & Body Screws 4 Stem Trials 5 Calcar Planers 6 Taper Adapters 7 Cutting Templates & Handle 8 Taper Adapter Handle 9 Humeral Trial Inserter/Extractor Catalog No. Description QTY Catalog No. Description QTY HDL-0920-043-001 Stem Trial Handle 3 INS-0950-046-001 Fracture Trial Inserter/Extractor 1 TRL-0920-020-08STD Body Trial, 8 Standard 1 TRL-0920-020-10SML Body Trial, 10 Small 1 TRL-0920-020-10STD Body Trial, 10 Standard 1 TRL-0920-020-10LRG Body Trial, 10 Large 1 TRL-0920-020-12STD Body Trial, 12 Standard 1 TRL-0920-020-14SML Body Trial, 14 Small 1 TRL-0920-020-14STD Body Trial, 14 Standard 1 TRL-0920-020-14LRG Body Trial, 14 Large 1 TRL-0950-020-08SML Fracture Body Trial, 8 Small 1 TRL-0950-020-08STD Fracture Body Trial, 8 Standard 1 TRL-0950-020-08LRG Fracture Body Trial, 8 Large 1 BSW-0920-021-01 Body Screws 2 TRL-0920-025-06 Humeral Stem Trial, 6mm 1 TRL-0920-025-07 Humeral Stem Trial, 7mm 1 TRL-0920-025-08 Humeral Stem Trial, 8mm 1 TRL-0920-025-09 Humeral Stem Trial, 9mm 1 TRL-0920-025-10 Humeral Stem Trial, 10mm 1 TRL-0920-025-11 Humeral Stem Trial, 11mm 1 TRL-0920-025-12 Humeral Stem Trial, 12mm 1 TRL-0920-025-13 Humeral Stem Trial, 13mm 1 TRL-0920-025-14 Humeral Stem Trial, 14mm 1 TRL-0920-025-15 Humeral Stem Trial, 15mm 1 TRL-0920-025-16 Humeral Stem Trial, 16mm 1 INS-0920-046-001 Humeral Trial Inserter/Extractor 1 RMR-0920-050-001 Calcar Planer, Small 1 RMR-0920-050-002 Calcar Planer, Large 1 ADT-0920-065-001 Taper Adapter 4 TMP-0920-040-001R Head Cutting Template, Right 1 TMP-0920-040-001L Head Cutting Template, Left 1 ROD-0920-040-002 Head Cutting Template, Handle 1 SCR-0920-066-001 Taper Adapter Shaft 1 INS-0950-045-001 Fracture Implant Inserter/Extractor 1 16

Instrumentation HUMERAL TRAY 2: INSERT 4 1 2 3 5 1 Ratcheting Screw Driver Handle 2 Eccentric Head Trial Hex Driver 3 Osteotomy Sizing Discs 4 Eccentric Head Trials 5 Concentric Head Trials Catalog No. Description QTY Catalog No. Description QTY G107992_B Driver Handle w/sm AO 1 SCR-0920-060-001 1/8 Hexdriver 1 HSP-0920-070-001E Head Sizing Plate, 38mm 1 HSP-0920-070-002E Head Sizing Plate, 40mm 1 HSP-0920-070-003 Head Sizing Plate, 42mm 1 HSP-0920-070-004 Head Sizing Plate, 44mm 1 HSP-0920-070-005 Head Sizing Plate, 46mm 1 HSP-0920-070-006 Head Sizing Plate, 48mm 1 HSP-0920-070-007 Head Sizing Plate, 50mm 1 HSP-0920-070-008 Head Sizing Plate, 52mm 1 TRL-0920-010-3814E Head Trial, Eccentric, 38x14mm 1 TRL-0920-010-4025E Head Trial, Eccentric, 40x15 mm 1 TRL-0920-010-4216E Head Trial, Eccentric, 42x16mm 1 TRL-0920-010-4416E Head Trial, Eccentric, 44x16mm 1 TRL-0920-010-4419E Head Trial, Eccentric, 44x19mm 1 TRL-0920-010-4614E Head Trial, Eccentric, 46x14mm 1 TRL-0920-010-4617E Head Trial, Eccentric, 46x17mm 1 TRL-0920-010-4620E Head Trial, Eccentric, 46x20mm 1 TRL-0920-010-4815E Head Trial, Eccentric, 48x15mm 1 TRL-0920-010-4818E Head Trial, Eccentric, 48x18mm 1 TRL-0920-010-4821E Head Trial, Eccentric, 48x21mm 1 TRL-0920-010-5019E Head Trial, Eccentric, 50x19mm 1 TRL-0920-010-5022E Head Trial, Eccentric, 50x22mm 1 TRL-0920-010-5220E Head Trial, Eccentric, 52x20mm 1 TRL-0920-010-4216C Head Trial, Concentric, 42x16mm 1 TRL-0920-010-4416C Head Trial, Concentric, 44x16mm 1 TRL-0920-010-4419C Head Trial, Concentric, 44x19mm 1 TRL-0920-010-4614C Head Trial, Concentric, 46x14mm 1 TRL-0920-010-4617C Head Trial, Concentric, 46x17mm 1 TRL-0920-010-4620C Head Trial, Concentric, 46x20mm 1 TRL-0920-010-4815C Head Trial, Concentric, 48x15mm 1 TRL-0920-010-4818C Head Trial, Concentric, 48x18mm 1 TRL-0920-010-4821C Head Trial, Concentric, 48x21mm 1 TRL-0920-010-5019C Head Trial, Concentric, 50x19mm 1 TRL-0920-010-5022C Head Trial, Concentric, 50x22mm 1 TRL-0920-010-5220C Head Trial, Concentric, 52x20mm 1 17

HUMERAL TRAY 2: BASE 1 6 2 4 3 5 7 8 11 10 9 1 Head Impactor 2 Body Screw Hex Driver 3 Torque Limiter 4 Head Extractor 5 Head Impaction Stand 6 Body/Stem Separator 7 Final Implant Inserter/Extractor 8 Head Impaction Stand Adapters 9 Body/Stem Impaction Stand 10 Body/Stem Impaction Handle 11 Slotted Mallet Catalog No. Description QTY IMP-0920-079-501 Head Impactor 1 SCR-0920-060-002 3/32 Hexdriver 1 G207153 Torque Limiter 1 SET188-A001 Head Extractor 1 STD-0920-071-001 Head Impaction Stand, Base Assembly 1 SEP-0920-068-001 Body Separator 1 INS-0920-045-001 Humeral Implant Inserter/Extractor 1 INS-0920-071-SML Head Impaction Stand Insert, Small 1 INS-0920-071-STD Head Impaction Stand Insert, Standard 1 INS-0920-071-LRG Head Impaction Stand Insert, Large 1 SIS-0920-054-001 Stem Impaction Stand 1 IMP-0920-055-001 Stem Impactor 1 G107991_B Slotted Mallet 1 18

Catalog Numbers And Implant Dimensions Press-Fit Stem Dimensions (mm), Ti Humeral Head Dimensions (mm), CoCr Diameter A Diameter B Diameter C Height Cemented Stem Dimensions (mm), CoCr Width A B C Length Spherical Diameter Ø PRESS-FIT STEM DIAMETER DIAMETER DIAMETER SPLINE NO. OF CATALOG NO. LENGTH A B C DEPTH SPLINES STEM-0920-025-06 90.4 11.6 6.8 4.6 1 12 STEM-0920-025-07 90.4 12.4 7.6 5.3 1 12 STEM-0920-025-08 90.4 13.7 9.0 6.6 1 12 STEM-0920-025-09 90.4 14.4 9.9 7.4 1 12 STEM-0920-025-10 90.4 15.4 10.9 8.5 1 12 STEM-0920-025-11 90.4 16.5 12.1 9.5 1 12 STEM-0920-025-12 90.4 17.5 13.2 10.6 1 12 STEM-0920-025-13 90.4 18.5 14.2 11.6 1 12 STEM-0920-025-14 90.4 19.5 15.3 12.6 1 12 STEM-0920-025-15 90.4 20.5 16.4 13.5 1 12 STEM-0920-025-16 90.4 21.5 17.4 14.7 1 12 CEMENTED STEM DIAMETER DIAMETER DIAMETER NO. OF CATALOG NO. LENGTH A B C FLUTES HUMERAL HEAD SPHERICAL OFFSET CATALOG NO. HEIGHT WIDTH DIAMETER Ø (ECCENTRIC) CONCENTRIC MHH-0920-010-3814X 14 38 41 2.5 No Option MHH-0920-010-4015X 15 40 43 2.5 No Option MHH-0920-010-4216X 16 42 45 4 C MHH-0920-010-4416X 16 44 48 4 C MHH-0920-010-4419X 19 44 45 4 C MHH-0920-010-4614X 14 46 54 4 C MHH-0920-010-4617X 17 46 49 4 C MHH-0920-010-4620X 20 46 47 4 C MHH-0920-010-4815X 15 48 56 4 C MHH-0920-010-4818X 18 48 51 4 C MHH-0920-010-4821X 21 48 49 4 C MHH-0920-010-5019X 19 50 53 4 C MHH-0920-010-5022X 22 50 51 4 C MHH-0920-010-5220X 20 52 55 4 C STEM-0950-025-06 90.4 9.6 6.1 4.6 4 STEM-0950-025-08 90.4 11.6 8.1 6.7 4 STEM-0950-025-10 90.4 13.4 9.9 8.5 4 STEM-0950-025-12 90.4 15.4 11.9 10.6 4 STEM-0950-025-14 90.4 17.5 14.0 12.6 4 CEMENTED LONG DIAMETER DIAMETER DIAMETER NO. OF STEM CATALOG NO. LENGTH A B C FLUTES STEM-0950-025-08125 125 11.5 8.0 6.0 4 STEM-0950-025-08165 165 11.5 8.0 6.0 4 STEM-0950-025-10125 125 13.5 10.0 8.0 4 STEM-0950-025-10165 165 13.5 10.0 8.0 4 STEM-0950-025-12125 125 15.5 12.0 10.0 4 STEM-0950-025-12165 165 15.5 12.0 10.0 4 Trunnion Offset Fracture Body Dimensions (mm), Ti Max Length Height Max Width Base Diameter FRACTURE BODY MAX MAX BASE TRUNNION CATALOG NUMBER HEIGHT LENGTH WIDTH DIAMETER OFFSET BOD-0950-020-08SML 30 16.7 11.6 11.6 8 BOD-0950-020-08STD 35 16.9 11.6 11.6 8 BOD-0950-020-08LRG 40 17.1 11.6 11.6 8 BSW-0920-021-01 Body Screw 19

20

Integra Titan Total Shoulder System For more information or to place an order, please contact: United States, Canada, Asia, Pacific, Latin America USA 877-444-1122 866-800-7742 fax n Outside USA 609-936-5400 609-750-4259 fax n integralife.com Europe, Middle-East, Africa International: +33 (0)4 37 47 59 50 n +33 (0)4 37 47 59 25 fax Benelux: +32 (0)2 257 4130 n +32 (0)2 253 2466 fax France: +33 (0)4 37 47 59 10 n +33 (0)4 37 47 59 29 fax Switzerland: +41 (0)22 721 23 00 n +41 (0)22 721 23 99 fax United Kingdom: +44 (0)1 264 345 781 n +44 (0)1 264 363 782 fax integralife.eu EC REP 0086 Manufacturer: Ascension Orthopedics, Ltd. BioPark Broadwater Road Welwyn Garden City Herts. AL7 3AX United Kingdom Ascension Orthopedics, Inc. 8700 Cameron Road Austin, Texas 78754 Availability of these products might vary from a given country or region to another, as a result of specific local regulatory approval or clearance requirements for sale in such country or region. n Always refer to the appropriate instructions for use for complete clinical instructions. n Non contractual document. The manufacturer reserves the right, without prior notice, to modify the products in order to improve their quality. n Warning: Applicable laws restrict these products to sale by or on the order of a physician. Additional information for EMEA Customers only: Products mentioned in this document are CE class I, IIa, IIb or III devices. Contact Integra should you need any additional information on devices classification. All the medical devices mentioned on this document are CE marked according to European council directive 93/42/EEC on medical devices and its relatives, unless specifically identified as NOT CE MARKED. Integra and the Integra logo are registered trademarks of Integra LifeSciences Corporation or its subsidiaries in the United States and/or other countries. Titan is a trademark of Integra LifeSciences Corporation or its subsidiaries. 2014 Integra LifeSciences Corporation. All rights reserved. Printed in USA. 0278440-1-EN LC-0927-002 Rev C