SIMPLIFIED CHIRAL SEPARATIONS. Lux Cellulose-1. Guaranteed Alternative. to CHIRALCEL OD-H. Exceptional Quality Sensibly Priced

Similar documents
SIMPLIFIED CHIRAL SEPARATIONS. FIVE Complementary Chiral Phases. for Greater Selectivity. Resolve 92 %

Lux. Five Distinct Polysaccharide Phases to Resolve 92 % of Your Enantiomers* Lux Cellulose-1. Lux Cellulose-3. Lux Cellulose-2.

Enantiomeric and Diastereoisomeric Resolutions of Chiral Triazole Fungicides using Lux Polysaccharide-Based Chiral Stationary Phases

APPLICATIONS TN Dramatically Improve Existing 5 µm and 3 µm Fully Porous Methods with Kinetex 5 µm Core-shell Technology.

Exceed your Purification Goals. Guaranteed. Phenomenex l WEB:

Finally, a Solid Phase Extraction product for Drugs of Abuse

Protect Your Mass Spec

APPLICATIONS TN Determination of Sugars in Animal Feed using HPLC-ELSD

Core-Shell Technology for Proteins and Peptides

Labs Across the World Are Advancing Their Protein Precipitation

Columns The FIRST and ONLY sub-2 µm core-shell columns on the market

Preparative Chromatography Meets UHPLC

APPLICATIONS TN Overview of Kinetex 2.6 µm Core-Shell Technology

APPLICATIONS Improving Intact Biogeneric Protein Separations with Aeris WIDEPORE Core-Shell Columns

NEW. Kinetex. Biphenyl TMS TMS TMS TMS. Selectivity that a C18 just can t give you!

Phospholipid Removal Solutions

METHAMPHETAMINE & AMPHETAMINE

APPLICATIONS TN µm Core-Shell Particle. (continued on page 2) Page 1 of 8. For additional technical notes, visit

APPLICATIONS TN A Comparison of Various Kinetex C18 Phases USP: L1

Run 1 Run 2 TDP PLP TDP PLP. 3.0e5 2.8e5 2.2e5. 2.6e5 2.4e5. 2.2e5 2.0e5. Intensity, cps. 1.8e5 1.6e5 1.4e5 1.2e5 1.0e5 4.0e4. 2.0e e5 1.

For Far. Greater. UHPLC Column Performance You Must Have Kinetex Core-Shell UHPLC Columns.

APPLICATIONS TN Analytical Method

A Fast, Accurate, and Sensitive Quantitiation of Vitamin C in Plasma by Impact Protein Precipitation and Kinetex 5 µm Core-Shell XB-C18 HPLC Columns

Rapid Analysis of Synthetic Cannabinoids and their Metabolites in Urine using Solid Phase Extraction and LC/MS/MS. JWH018-4-Hydroxypentyl metabolite

Keep it Clean with Strata -X

APPLICATIONS TN Materials and Methods

Yes You Can! New! Amazing EVO C18. Core-Shell Technology

Figure 1. Core-Shell Particle Technology

APPLICATION TN Materials and Methods Reagents and Chemicals

PAIN PANEL. Research and Solutions

APPLICATIONS TN A Sensitive Extraction Method for Nicotine and Metabolites from Urine using Simplified Liquid Extraction (SLE)

Core-Shell Technology. 11 HPLC Myths. Uncovered. & Why You Must Have Kinetex Core-Shell HPLC Columns

Keep It Clean. Solid Phase Extraction Solutions for Drugs of Abuse Analysis. Neutral Drugs of Abuse Basic Drugs of Abuse

COMBO ULTIMATE HPLC/UHPLC. Kinetex + Luna Omega NEW. Gain Incredible Performance, Versatile Selectivities and Upgrade Throughput

APPLICATIONS TN Rapid Analysis of Hop Acids in Beer using Strata -X Solid Phase Extraction and Kinetex 2.6 µm Core-Shell Technology Column

Supported Liquid Extraction (SLE) For Food Applications

Confidence. A New Standard of. Calibration, Surrogate, & Internal Standards for Environmental Analysis

PAIN PANEL. Application Guide. Screen 41 compounds in under 4 minutes

A New Era in SFC Column Technology

Prep Columns. and Bulk Media. and Bulk Media

Ultimate Core Performance to Maximize Your Investment

Awesome! Unconventionally. Kinetex EVO C18 HPLC/UHPLC Core-Shell Columns 2.6. Core-Shell Technology

Aeris. Precision Engineered Core- Shell Particles for Ultra-High Resolution BioSeparations. Aeris PEPTIDE. Aeris WIDEPORE

NEW Kinetex F5. HPLC/UHPLC Core-Shell Columns

Comparison of Different Whole Blood Sample Pretreatment Methods for Targeted Analysis of Basic Drugs. Table 1. List of pain panel drugs

Immobilized Chiral Stationary Phases

APPLICATION TN Rapid Analysis of a 48 Drug Research Panel in Less Than 4 Minutes Using Kinetex Biphenyl Core-Shell Technology HPLC/UHPLC Columns

COSMOSIL CHiRAL Series

APPLICATIONS TN Rapid, High Resolution Analysis of Aflatoxin Extracts from Peanut Butter Using Kinetex Core-Shell Technology and Strata SPE

Strata-X- NEW! Drug B. Drug B Plus for In-Well Hydrolysis. Simplify Your Solid Phase Extraction.

CANNABIS TESTING ACCESSORIES

TN-0116 Scott Krepich

Vitamin Testing APPLICATIONS GUIDE

SecurityGuard. Column Protection for UHPLC, HPLC to PREP. A Universal Guard Cartridge System. Increases HPLC Column Lifetime, Guaranteed!

CANNABIS TESTING. LC/GC/SFC/SPE/QuEChERS. Analytical Options For Your Laboratory Needs.

Separations. Sweet Sugar. Are in Your Future. New. Luna Omega SUGAR LC Column OMEGA

Reproducible Separation of Carbohydrate, Oligosaccharide, and Organic Acid Analysis. Accurate and reproducible analysis Long column lifetimes

An Easier QuEChERS Solution for Diverse Matrices. Learn more at

Shuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W

New Luna Omega. Columns. The Final Word in Fully Porous UHPLC

C30 ISOMERS HAVE MET THEIR MATCH

[ APPLICATION NOTE ] The Separation of 8 -THC, 9 -THC, and Their Enantiomers by UPC 2 Using Trefoil Chiral Columns INTRODUCTION APPLICATION BENEFITS

A New HILIC/RP Mixed-Mode Column and Its Applications in Surfactant Analysis

A Validated Chiral Liquid Chromatographic Method for The Enantiomeric Separation of Dapoxetine Hydrochloride

Effective use of Pharmacopeia guidelines to reduce cost of chromatographic analysis for Fluticasone propionate

Analytical Method Development for USP Related Compounds in Paclitaxel Using an Agilent Poroshell 120 PFP

Core-Shell Technology. Kinetex. Columns. The chosen core-shell brand to drive UHPLC performance to the next level. Core-Shell Technology

YMC Chiral columns. Polysaccharides NEA(R)(S) CD BR

Choosing Preparative Columns

APPLICATIONS TN Determination of Sterols in Olive Oil using Supported Liquid Extraction (SLE), Solid Phase Extraction (SPE) and GC-FID

Chemical compatibility of the Pall QPoint TM Docking Station - Tap Assembly with common surface disinfectants

ZB-FAME The Fast FAME GC Column

HPLC. Varian Dynamax Preparative HPLC Columns

Chiral Screening for SFC and UHPLC with the Agilent 1260 Infinity II SFC/UHPLC Hybrid System

YMC CHIRAL columns. Polysaccharides NEA(R)(S) CD BR

ACQUITY UPLC WITH PDA DETECTION: DETERMINING THE SENSITIVITY LIMITS OF OXYBUTYNIN AND RELATED COMPOUNDS

The Investigation of Factors Contributing to Immunosuppressant Drugs Response Variability in LC-MS/MS Analysis

Impact of Reversed-Phase Chiral Chromatography on the LC-MS Analysis of Drugs in Biological Fluids

ACE Excel UHPLC Columns

Impurity Profiling of Carbamazepine by HPLC/UV

Kromasil The way to peak performance in liquid chromatography

STANDARD OPERATING PROTOCOL (SOP)

Providing a Universal, One-step Alternative to Liquid-Liquid Extraction in Bioanalysis

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development

Analysis of Amino Acids Derived Online Using an Agilent AdvanceBio AAA Column

High-Resolution Analysis of Intact Triglycerides by Reversed Phase HPLC Using the Agilent 1290 Infinity LC UHPLC System

GlycanPac AXR-1 Columns

Selectivity Comparison of Agilent Poroshell 120 Phases in the Separation of Butter Antioxidants

InertSustainBio C18. Rapid Separations of Proteins and Peptides

Sepax Technologies, Inc.

autosamplers ASI-100 and ASI-100T Autosamplers

UHPLC Column and System Protection Essentials

artus EBV QS-RGQ Kit Performance Characteristics May 2012 Sample & Assay Technologies Analytical sensitivity plasma

Phenyl-Hexyl. UHPLC Columns. lternate, complementary selectivity to C18 and C8 bonded phases

PyroMark Q24 CpG MGMT Handbook

Analysis of the Non-Ionic Surfactant Triton-X Using UltraPerformance Convergence Chromatography (UPC 2 ) with MS and UV Detection

YMC-Actus. Columns for Semi-preparative HPLC. Selectivity Durability Loadability

High-Throughput Quantitative LC-MS/MS Analysis of 6 Opiates and 14 Benzodiazepines in Urine

ApplicationNOTE EXACT MASS MEASUREMENT OF ACTIVE COMPONENTS OF TRADITIONAL HERBAL MEDICINES BY ORTHOGONAL ACCELERATION TIME-OF-FLIGHT.

Chiral Multicolumn Method Development on the Agilent 1260 Infinity II SFC System

Transcription:

SIMPLIFIED IRAL SEPARATIS Lux ellulose- Guaranteed Alternative to IRALEL D- Exceptional Quality Sensibly Priced

Lux ellulose- ellulose tris(3,5-dimethylphenylcarbamate) This dimethyl cellulose selector is famous around the world for its ability to separate aromatic, conjugated, and other challenging chiral compounds. Advantages of using Lux ellulose- Proven universal selector Available in 3 µm, 5 µm, and 0 µm Sensibly priced Stable up to 300 bar (4,350 psi) Easy solvent switching Meet the Rest of the Lux Family! Lux ellulose- cellulose tris(3-chloro-4- methylphenylcarbamate) Lux ellulose-3 cellulose tris(4-methylbenzoate) Lux ellulose-4 cellulose tris(4-chloro-3- methylphenylcarbamate) Lux Amylose- amylose tris(5-chloro-- methylphenylcarbamate) - - - - -3-3 -3-3 -4-4 -4-4 A- A- A- A- l l l l l l l l l l l ackbone ellulose ellulose Backbone Backbone ellulose Backbone ellulose Backbone ellulose ellulose Backbone Backbone ellulose Backbone ellulose Backbone hlorinated ellulose ellulose Ester ellulose ellulose Backbone Backbone ellulose Backbone ellulose Backbone Amylose Amylose Backbone Backbone Amylose Backbone Amylose Backb hlorinated ellulose hlorinated Amylose The Lux line of SPs offers 5 complementary selectivities 00 Phenomenex, Inc. All rights reserved.

Guaranteed Alternative to IRALEL D- SIMPLIFIED IRAL SEPARATIS If Lux analytical columns ( 4.6 mm ID) do not provide at least an equivalent or better separation as compared to a competing column of the same particle size, similar phase and dimensions, send in your comparative data within 45 days and keep the Lux column for FREE. Ambucetamide Lux 5 µm ellulose- a =.09 0 4 App ID 74 6 8 min onditions for both columns: Dimensions: 50 x 4.6 mm Mobile Phase: 0. % Diethylamine in Methanol / 0. % Diethylamine in Isopropanol (90:0) Flow Rate: ml/min Detection: UV @ 0 nm 74 *IRALEL 5 µm D- a =.83 0 Metoprolol Lux 5 µm ellulose- a =.38 omifensine 3 4 5 6 7 8 9 min 0 3 4 5 *IRALEL 5 µm D- a =.8 0 Lux 5 µm ellulose- a =.0 min 3 4 5 min App ID 7454 App ID 743 App ID 74 App ID 744 onditions for both columns: Dimensions: 50 x 4.6 mm Mobile Phase: 0. % Diethylamine in Acetonitrile / 0. % Diethylamine in Isopropanol (95:5) Flow Rate: ml/min Detection: UV @ 0 nm 3 onditions for both columns: Dimensions: 50 x 4.6 mm Mobile Phase: 0. % Diethylamine in Acetonitrile / 0. % Diethylamine in Isopropanol (95:5) Flow Rate: ml/min Detection: UV @ 0 nm 3 3 0 4 6 min *IRALEL 5 µm D- a =. App ID 7456 3 0 3 4 5 min 3

Specialized oating Process and Expert Packing Provides ptimal olumn Performance. ur robust coating and packing process allows you to enjoy increased loading capacity, column reproducibility, and exceptional enantiomeric resolution. Achieve the optimal efficiencies you desire without sacrificing chiral recognition abilities. Tolperisone Lux 5 µm ellulose- a =.09 App ID 73 onditions for both columns: Dimensions: 50 x 4.6 mm Mobile Phase: 0. % Diethylamine in exane / 0. % Diethylamine in Isopropanol (90:0) Flow Rate: ml/min Detection: UV @ 0 nm 0 3 4 5 6 min *IRALEL 5 µm D- a =.07 0 Metofoline Lux 5 µm ellulose- a =.3 4 6 min 0 3 4 5 6 min *IRALEL 5 µm D- a =.0 0 3 4 5 6 min Temazepam Lux 5 µm ellulose- a =.39 App ID 745 App ID 7405 App ID 7404 App ID 73 3 onditions for both columns: l onditions for both columns: 3 Dimensions: 50 x 4.6 mm Mobile Phase: 0. % Diethylamine in Methanol / 0. % Diethylamine in Isopropanol (90:0) Flow Rate: ml/min Detection: UV @ 0 nm Dimensions: 50 x 4.6 mm Mobile Phase: 0. % Diethylamine in Acetonitrile / 0. % Diethylamine in Isopropanol (95:5) Flow Rate: ml/min Detection: UV @ 0 nm 0 3 4 5 6 7 8 min 3 *IRALEL 5 µm D- a =.8 App ID 747 l 0 3 4 5 6 7 8 min 4

Extreme Stability and Separating Power under SF onditions. ever fear crushed media or loss in efficiency again. With a pressure stability up to 300 bar (4,350 psi), you can feel confident about running at high operating pressures (if necessary). Lux media is SF approved and versatile enough to satisfy all of your chiral separation needs. SIMPLIFIED IRAL SEPARATIS Bifonazole onditions for both columns: 0 0 0 Lux 5 µm ellulose- a =.08 4 6 8 0 4 6 8 0 4 min *IRALEL 5 µm D- a =.0 Atenolol 4 6 8 0 4 6 8 0 4 min 4 6 8 0 4 6 8 0 4 6 8 min Lux 5 µm ellulose- a =.97 *IRALEL 5 µm D- a =.64 App ID 900 App ID 8855 App ID 90 App ID 9098 Dimensions: 50 x 4.6 mm Mobile Phase: 0. % Diethylamine in Methanol / arbon Dioxide (5:85) Flow Rate:.5 ml/min Temperature: 35 Detection: Diode Array Detector onditions for both columns: Dimensions: 50 x 4.6 mm Mobile Phase: 0. % Diethylamine in Methanol / arbon Dioxide (0:80) Flow Rate:.5 ml/min Temperature: 35 Detection: Diode Array Detector 3 3 0 4 6 8 0 4 6 8 0 4 6 8 min 5

Easy hiral Method Development Resolve 9 % of your enantiomers with five complementary Lux phases.* To get you started, we have outlined a simple strategy for screening SPs under PL and SF conditions in our chiral method development solutions poster. all or go online today to create your own custom screening kit or to request a chiral method development solutions poster at www.phenomenex.com/info/lux *Based on screening 33 compounds on all five Lux Phases hiral Screening and Separation Services PL SF Preparative Training hiral Phase Screening Method ptimization Method Re-Validation Scale-Up Services n-site Training For more information on our services or to begin a project, please contact your local Phenomenex chiral expert or email us at: phenologics@phenomenex.com You can also visit us on the web: www.phenomenex.com/phenologics 6

SIMPLIFIED IRAL SEPARATIS rdering Information 3 µm Analytical olumns (mm) SecurityGuard artridges (mm) 50 x.0 50 x.0 50 x 4.6 00 x 4.6 50 x 4.6 50 x 4.6 4 x.0* 4 x 3.0* Phases /0pk /0pk ellulose- 00B-4458-B0 00F-4458-B0 00B-4458-E0 00D-4458-E0 00F-4458-E0 00G-4458-E0 AJ0-840 AJ0-8403 ellulose- 00B-4456-B0 00F-4456-B0 00B-4456-E0 00D-4456-E0 00F-4456-E0 00G-4456-E0 AJ0-8398 AJ0-8366 ellulose-3 00B-449-B0 00F-449-B0 00B-449-E0 00D-449-E0 00F-449-E0 00G-449-E0 AJ0-86 AJ0-86 ellulose-4 00B-4490-B0 00F-4490-B0 00B-4490-E0 00D-4490-E0 00F-4490-E0 00G-4490-E0 AJ0-866 AJ0-867 Amylose- 00B-447-B0 00F-447-B0 00B-447-E0 00D-447-E0 00F-447-E0 00G-447-E0 AJ0-847 AJ0-8470 for ID:.0 3.0 mm 3. 8.0 mm 5 µm Analytical olumns (mm) SecurityGuard artridges (mm) 50 x.0 50 x 4.6 00 x 4.6 50 x 4.6 50 x 4.6 4 x.0* 4 x 3.0* Phases /0pk /0pk ellulose- 00B-4459-B0 00B-4459-E0 00D-4459-E0 00F-4459-E0 00G-4459-E0 AJ0-840 AJ0-8403 ellulose- 00B-4457-B0 00B-4457-E0 00D-4457-E0 00F-4457-E0 00G-4457-E0 AJ0-8398 AJ0-8366 ellulose-3 00B-4493-B0 00B-4493-E0 00D-4493-E0 00F-4493-E0 00G-4493-E0 AJ0-86 AJ0-86 ellulose-4 00B-449-B0 00B-449-E0 00D-449-E0 00F-449-E0 00G-449-E0 AJ0-866 AJ0-867 Amylose- 00B-447-B0 00B-447-E0 00D-447-E0 00F-447-E0 00G-447-E0 AJ0-847 AJ0-8470 for ID:.0 3.0 mm 3. 8.0 mm 5 µm Semi-Prep olumns (mm) SecurityGuard artridges (mm) 50 x 0.0 50 x 0.0 0 x 0.0 Phases /3pk ellulose- 00F-4459-0 00G-4459-0 AJ0-8404 ellulose- 00F-4457-0 00G-4457-0 AJ0-8399 ellulose-3 00F-4493-0 00G-4493-0 AJ0-863 ellulose-4 00F-449-0 00G-449-0 AJ0-868 Amylose- 00F-447-0 00G-447-0 AJ0-847 for ID: 9 6 mm 0 µm Bulk Media 00 g kg Phases ellulose- 04G-4473 04K-4473 ellulose- 04G-4464 04K-4464 Amylose- Please inquire for 0 µm Lux Amylose-, ellulose-3 or ellulose-4 media. 5 µm Axia Packed Preparative olumns (mm) SecurityGuard artridges (mm) 50 x. 50 x. 50 x 30 50 x 50 5 x.** 5 x 30.0 + Phases /ea /ea ellulose- 00F-4459-P0-AX 00G-4459-P0-AX 00G-4459-U0-AX 00G-4459-V0-AX AJ0-8405 AJ0-8406 ellulose- 00F-4457-P0-AX 00G-4457-P0-AX 00G-4457-U0-AX 00G-4457-V0-AX AJ0-8400 AJ0-840 ellulose-3 00F-4493-P0-AX 00G-4493-P0-AX 00G-4493-U0-AX 00G-4493-V0-AX AJ0-864 AJ0-865 ellulose-4 00F-449-P0-AX 00G-449-P0-AX 00G-449-U0-AX 00G-449-V0-AX AJ0-869 AJ0-8630 Amylose- 00F-447-P0-AX 00G-447-P0-AX 00G-447-U0-AX 00G-447-V0-AX AJ0-8473 AJ0-8474 for ID: 8 9 mm 30 49 mm *SecurityGuard Analytical artridges require holder, Part o. : KJ0-48 SemiPrep SecurityGuard artridges require holder, Part o. : AJ0-70 **PREP SecurityGuard artridges require holder, Part o. : AJ0-83 + PREP SecurityGuard artridges require holder, Part o. : AJ0-877 3 µm Method Screening Kits (save 0 % when purchased as a kit) 50 x 4.6 mm 50 x 4.6 mm Screening Kit K0-8483 K0-848 Kit contains one column of each phase. olumn Performance heck Standard Part o. Description Unit Price AL0-84 hiral Test Mix o. 5 (Lux) ea Terms and onditions Subject to Phenomenex Standard Terms & onditions, which may be viewed at www.phenomenex.com/termsandonditions. Trademarks IRALEL and D- are registered trademarks of DAIEL hemical Industries, Ltd. Axia, Lux, and SecurityGuard are trademarks of Phenomenex, Inc. Disclaimer omparative separations may not be representative of all applications. olumns used for comparison were manufactured by DAIEL hemical Industries, Ltd. Phenomenex is not affiliated with DAIEL hemical Industries. 00 Phenomenex, Inc. All rights reserved. If Lux analytical columns ( 4.6 mm ID) do not provide at least an equivalent or better separation as compared to a competing column of the same particle size, similar phase and dimensions, send in your comparative data within 45 days and keep the Lux column for FREE. 7

Australia t: 0-948-6444 f: 0-948-6445 auinfo@phenomenex.com Austria t: 0-39-30 f: 0-39-300 anfrage@phenomenex.com Belgium t: +3 (0)30-48700 f: +3 (0)30-383749 beinfo@phenomenex.com anada t: (800) 543-368 f: (30) 38-7768 info@phenomenex.com Denmark t: 484 8048 f: 480 665 nordicinfo@phenomenex.com Finland t: (09)4789 0063 f: +45 480 665 nordicinfo@phenomenex.com France t: 0 30 09 0 f: 0 30 09 franceinfo@phenomenex.com Germany t: 060-58830-0 f: 060-58830- anfrage@phenomenex.com Ireland t: 0 47 5405 f: +44 65-50796 eireinfo@phenomenex.com Italy t: 05 6375 f: 05 637555 italiainfo@phenomenex.com Luxembourg t: +3 (0)30-48700 f: +3 (0)30-383749 nlinfo@phenomenex.com Mexico t: (55) 508 379 f: (30) 38-7768 tecnicomx@phenomenex.com The etherlands t: 030-48700 f: 030-383749 nlinfo@phenomenex.com ew Zealand t: 09-478095 f: 09-478095 nzinfo@phenomenex.com orway t: 8 00 0 05 f: +45 480 665 nordicinfo@phenomenex.com Puerto Rico t: (800) 54-PL f: (30) 38-7768 info@phenomenex.com United Kingdom t: 065-50367 f: 065-50796 ukinfo@phenomenex.com All other countries: orporate ffice USA t: (30) -0555 f: (30) 38-7768 info@phenomenex.com BR739400_I www.phenomenex.com Phenomenex products are available worldwide. For the distributor in your country, contact Phenomenex USA, International Department at international@phenomenex.com