The Role of the RNFL in the Diagnosis of Glaucoma

Similar documents
Intro to Glaucoma/2006

STRUCTURE & FUNCTION An Integrated Approach for the Detection and Follow-up of Glaucoma. Module 3a GDx

Study of Retinal Nerve Fiber Layer Thickness Within Normal Hemivisual Field in Primary Open-Angle Glaucoma and Normal-Tension Glaucoma

OCT in the Diagnosis and Follow-up of Glaucoma

Relationship between the GDx VCC and Stratus OCT in Primary Open Angle Glaucoma

Glaucoma: Diagnostic Modalities

Early Detection Of Glaucoma Clinical Clues. Points To Live By. Glaucoma Risk Factors 10/3/2014

Linking structure and function in glaucoma

A Review Of Risk Factors. Early Detection Of Glaucoma Clinical Clues. A risk factor analysis is critical. Points To Live By

OtticaFisiopatologica

Noel de Jesus Atienza, MD, MSc and Joseph Anthony Tumbocon, MD

The Optic Nerve Head In Glaucoma. Clinical Pearl #1. Characteristics of Normal Disk 9/26/2017. Initial detectable damage Structure vs function

Optic Disc Evaluation: Is the Optic Disc Glaucomatous and Has it Progressed?

Corporate Medical Policy

The Effect of Pupil Dilation on Scanning Laser Polarimetry With Variable Corneal Compensation

MEDICAL POLICY. Proprietary Information of Excellus Health Plan, Inc. A nonprofit independent licensee of the BlueCross BlueShield Association

A comparison of HRT II and GDx imaging for glaucoma detection in a primary care eye clinic setting

Summary HTA HTA-Report Summary Validity and cost-effectiveness of methods for screening of primary open angle glau- coma

Correlating Structure With Function in End-Stage Glaucoma

3/23/2016. Regina Smolyak, MD Glaucoma Service Flaum Eye Institute

Relationship between GDx VCC and Stratus OCT in juvenile glaucoma

C a t a r a c t G l a u c o m a R e t i n a R e f r a c t i v e. The GDxVCC Early answers and ongoing assessment for glaucoma

Macular Ganglion Cell Complex Measurement Using Spectral Domain Optical Coherence Tomography in Glaucoma

Goals. Glaucoma PARA PEARL TO DO. Vision Loss with Glaucoma

Relationship Between Structure

Retinal Nerve Fiber Analysis: the Role It Plays in Assessing Glaucoma Grace Martin, CPOT

In some patients with glaucoma, standard (achromatic) automated

Clinical decision making based on data from GDx: One year observations

MEDICAL POLICY. Proprietary Information of YourCare Healthcare

Retinal Nerve Fiber Layer Measurements in Myopia Using Optical Coherence Tomography

Scanning Laser Polarimetry and Optical Coherence Tomography for Detection of Retinal Nerve Fiber Layer Defects

CLINICAL SCIENCES. Felipe A. Medeiros, MD; Linda M. Zangwill, PhD; Christopher Bowd, PhD; Robert N. Weinreb, MD

Evaluating Optic Nerve Damage: Pearls and Pitfalls

Discrimination between normal and glaucomatous eyes with visual field and scanning laser polarimetry measurements

Retinal nerve fiber layer measured by Heidelberg retina tomograph and nerve fiber analyzer

Optic Nerve: Clinical Examination

THE BASIC PATHOLOGIC CHANGE IN GLAUCOMA IS

Sensitivity and specificity of new GDx parameters Colen TP, Tang NEML, Mulder PGH and Lemij HG Submitted for publication CHAPTER 7

Targeting Intraocular Pressure in Glaucoma: a Teaching Case Report 1

PRACTICAL APPROACH TO MEDICAL MANAGEMENT OF GLAUCOMA

The Relationship between Standard Automated Perimetry and GDx VCC Measurements METHODS

Scanning laser polarimetry (SLP) provides real-time, objective

53 year old woman attends your practice for routine exam. She has no past medical history or family history of note.

S Morishita, T Tanabe, S Yu, M Hangai, T Ojima, H Aikawa, N Yoshimura. Clinical science

Beyond the C/D Ratio: Evaluating a Glaucomatous Optic Nerve. Marcus Gonzales, OD, FAAO Cedar Springs Eye Clinic COPE ID#: GL

Retinal nerve fiber layer thickness in Indian eyes with optical coherence tomography

Detection of Progressive Retinal Nerve Fiber Layer Loss in Glaucoma Using Scanning Laser Polarimetry with Variable Corneal Compensation

Evaluation of retinal nerve fiber layer thickness parameters in myopic population using scanning laser polarimetry (GDxVCC)

Detection of Glaucoma Using Scanning Laser Polarimetry with Enhanced Corneal Compensation

Diagnostic Accuracy of Scanning Laser Polarimetry with Enhanced versus Variable Corneal Compensation

Glaucoma Progression. Murray Fingeret, OD

5/12/2014. Lynn E. Lawrence, CPOT, ABOC, COA

Seiji T. Takagi, Yoshiyuki Kita, Asuka Takeyama, and Goji Tomita. 1. Introduction. 2. Subjects and Methods

New Concepts in Glaucoma Ben Gaddie, OD Moderator Murray Fingeret, OD Louis Pasquale, MD

Glaucoma Clinical Update. Barry Emara MD FRCS(C) Giovanni Caboto Club October 3, 2012

CLINICAL SCIENCES. Steven L. Mansberger, MD; Pamela A. Sample, PhD; Linda Zangwill, PhD; Robert N. Weinreb, MD

CLINICAL SCIENCES. optic neuropathy characterized

Diagnostic Accuracy of OCT with a Normative Database to Detect Diffuse Retinal Nerve Fiber Layer Atrophy: Diffuse Atrophy Imaging Study METHODS

Parafoveal Scanning Laser Polarimetry for Early Glaucoma Detection

Ganglion cell complex scan in the early prediction of glaucoma

Is NTG different from POAG?

GLAUCOMA SUMMARY BENCHMARKS FOR PREFERRED PRACTICE PATTERN GUIDELINES

Glaucoma Diagnosis. Definition of Glaucoma. Diagnosing Glaucoma. Vision Institute Annual Fall Conference

Glaucoma Evaluation. OCT Pearls for Glaucoma. OCT: Retinal Nerve Fiber Layer. Financial Disclosures. OCT: Macula. Case Example

Patterns of Subsequent Progression of Localized Retinal Nerve Fiber Layer Defects on Red-free Fundus Photographs in Normal-tension Glaucoma

Peripapillary Retinal Thickness. Maps in the Evaluation of Glaucoma Patients: A Novel Concept.

G laucoma is a progressive optic neuropathy in which

CLINICAL SCIENCES. Differences in Visual Function and Optic Nerve Structure Between Healthy Eyes of Blacks and Whites

The only measure of RNFL Integrity : GDxPRO

Investigation of the relationship between central corneal thickness and retinal nerve fiber layer thickness in ocular hypertension

Detection of Glaucoma Based on CDR, CAR and Blood Vessel Extraction

Structural examina.on: Imaging

Correlation of Blue Chromatic Macular Sensitivity with Optic Disc Change in Early Glaucoma Patients

Behandlungsstrategien beim Offenwinkelglaukom. F. Bochmann, Augenklinik LUKS

The evaluation of retinal nerve fiber layer in pigment dispersion syndrome and pigmentary glaucoma using scanning laser polarimetry

RETINAL NERVE FIBER LAYER

Translating data and measurements from stratus to cirrus OCT in glaucoma patients and healthy subjects

The evaluation of the optic nerve and retinal nerve

Scanning Laser Tomography to Evaluate Optic Discs of Normal Eyes

* Şükrü Bayraktar, MD, Zerrin Bayraktar, MD, and Ömer Faruk Yilmaz, MD

Evolving glaucoma management True diagnostic integration for the preservation of vision

The only measure of RNFL Integrity: GDxPRO

Eye Movements, Strabismus, Amblyopia, and Neuro-Ophthalmology

Diagnostic Accuracy of the Optical Coherence Tomography in Assessing Glaucoma Among Filipinos. Part 2: Optic Nerve Head and Retinal

Ability of Scanning Laser Polarimetry (GDx) to Discriminate among Early Glaucomatous, Ocular Hypertensive and Normal Eyes in the Korean Population

To assess the glaucoma diagnostic ability of Fourier Domain Optical Coherence Tomography

CHAPTER 13 CLINICAL CASES INTRODUCTION

LARGE DISCS WITH LARGE CUPS A DIAGNOSTIC CHALLENGE IN AFRICAN PATIENTS. Darshana Soma

The Measure of Confidence

Financial Disclosure. Maximizing OCT in Diagnosis and Management of Glaucoma. Case 1: Dennis, 65yo WM DIAGNOSIS: CASES 1 2 7/29/2016

Advances in OCT Murray Fingeret, OD

Collaboration in the care of glaucoma patients and glaucoma suspects. Barry Emara MD FRCS(C) Nico Ristorante November 29, 2012

1/25/2019 OCT & OCTA RETINAL IMAGING: HOW TO PREVENT RAGING GLAUCOMA! THE ORIGINAL RAGING GLAUCOMA OCT RETINAL IMAGING OPTIC NERVE HEAD EXAMINATION

NIH Public Access Author Manuscript Arch Ophthalmol. Author manuscript; available in PMC 2013 October 01.

Optic disc damage has been shown to precede visual field

Ophthalmologic Techniques That Evaluate the Posterior Segment for Glaucoma

Key words: Glaucoma, Imaging, Ophthalmoscopy, Optic neuropathy, Topography

Rarebit perimetry and frequency doubling technology in patients with ocular hypertension

University Hospital Basel. Optical Coherence Tomography Emerging Role in the Assessment of MS PD Dr. Konstantin Gugleta

The Missing Piece in Glaucoma?

Transcription:

Chapter 1. The Role of the RNFL in the Diagnosis of Glaucoma Introduction Glaucoma is an optic neuropathy characterized by a loss of of retinal ganglion cells and their axons, the Retinal Nerve Fiber Layer (RNFL). It is one of the leading causes of blindness in the world1-8. Prevalence of glaucoma is on the increase as the world population ages. In the United States, experts expect that the number of glaucoma patients will increase from the current estimate of 2.5 million to at least 3.4 million by the year 20209. The loss of Retinal ganglion cells in glaucoma is irreversible, therefore early detection is critical to prevent progression of the disease. A quote from Professor Robert N. Weinreb, former President of the Association for Research in Vision and Ophthalmology (ARVO) and Director of the Hamilton Glaucoma Center at the University of California San Diego, succinctly states this point, "If you diagnose glaucoma early, you can treat it early. If you treat glaucoma early, you can slow the rate of progression. If you slow the rate of progression, you prevent blindness14." Major risk factors for glaucoma include intraocular pressure (lop), age, race, family history, myopia, and corneal thickness. These risk factors provide important information for the clinician when making a diagnosis. For example, African Americans are 6 times more likely to have glaucoma than Caucasians and POAG appears approximately 10 years earlier in African Americans10-13. Glaucoma Diagnosis Glaucoma diagnosis is based on the assessment of intraocular pressure (lop), optic nerve head (ONH), visual function, and less frequently the retinal nerve fiber layer (RNFL). There are certain advantages and disadvantages associated with each of these measures, ranging from the discriminating power of the measure (e.g., the large overlap between normals and glaucoma of lop results in poor discrimination), to more practical considerations such as how easy is it to obtain high quality results that are reproducible. A central factor of any measure is whether it is subjective or objective. Methods that involve a subject's response are subjective and frequently have high variabiliti5 and can improve with practice (e.g., visual fields). Subjective methods may also require a high level of expertise for accurate 251-0083C 5

interpretation of the results (e.g., expert interpretation of optic disc photographs will be different from less experienced clinicians). Objective methods are less commonly used in a clinical setting. However, structural analysis with imaging devices that provide objective information is becoming more common. This type of objective method provides unique and highly discriminating information that cannot be obtained routinely (e.g., Scanning Laser Polarimetry provides RNFL information that cannot be visualized by the clinician, see Chapter 2 for more details on the principles of SLP). Structural analysis with an imaging device that provides objective measures has been recommended by the world's leading glaucomaexpertsto be includedin the standardexamof all glaucomapractices16. Glaucoma Diagnosis: lop Assessment Intraocular pressure is the number one risk factor for glaucoma. A high lop is the hallmark for most of the glaucomas, and the treatment for glaucoma is to lower the lop through medications or surgery. Tonometry is simple and fast, and it is one of the most heavily relied on measures for glaucoma diagnosis. However, a major limitation of lop is that the damage threshold varies across individuals. For example, the majority of individuals with high lop (ocular hypertensives) do not have glaucoma, and will not develop glaucoma17. Conversely, other individuals will develop glaucoma, even with lops in the normal range (Normal tension glaucoma)18. Anotherlimitationof lop is that the diurnalfluctuationscan concealhigh lop spikes19. Measuring a diurnal lop curve can help with this limitation, but is impractical for routine clinical use. lop assessment is also limited because corneal thickness affects the accuracy of the lop measurement. It is known that thicker than average corneas will overestimate lop and thinner than average corneas will underestimate IOP2o. Thus corneal thickness must be taken into account when measuring the lop. Clinical studies have found that the large overlap of lop in healthy eyes and glaucomatous eyes limits the diagnostic accuracy of lop for detecting glaucoma. Diagnostic accuracy is measured by calculating the sensitivity and specificity of a measure using a specific cut-off value, or more generally by calculating the area under the ROC curve (see Appendix A. for a description of sensitivity and specificity and ROC analysis). A study by Leske et al.21measured the discriminating ability of lop in a large population (the Barbados Eye study), and found the sensitivity for detecting glaucoma was 79% with a speci- 6 251-0083C

ficity of 64%. Despite the fact that lop measurements are simple and convenient to use, and that they have a strong tradition in glaucoma care, the large difference between normals and patients in damage thresholds as well as the other limitations prevent lop from being a sufficient diagnostic tool by itself for glaucoma. Glaucoma Diagnosis: ONH Assessment Optic nerve head (ONH) assessment with ophthalmoscopy, biomicroscopy and stereophotography is an important tool to detect and monitor glaucoma. This method involves the clinical examination of the ONH to detect abnormalities associated with glaucoma such as rim thinning, notching, excavation, presence of hemorrhages, large Cup/Disc (C/D) ratios or asymmetric C/D ratios (> 0.2 betweeneyes). The meanc/d ratiofor a normaleye is 004,andthe 97.Sth percentilefromthe normaldistribution is 0.7, therefore C/D ratios above 0.7 are indicative of glaucoma22. Furthermore, the C/D ratio in normal eyes remains stable over time, therefore an observed change in the C/D ratio is also indicative of glaucoma. Documentation of the ONH findings from ophthalmoscopy and biomicroscopy is made with drawings, which can be difficult to use when evaluating changes over time. ONH stereo-photography produces a high resolution image of the optic disc and peripapillary retina and creates a permanent record for close evaluation and future comparisons. Limitations of this technique include the requirement of clear media and a dilated pupil. For ONH stereo-photography, a skilled photographer is needed, and the results are not immediately available. Even under ideal conditions, adequate quality can only be obtained approximately 80% of the time23. ONH assessment is a subjective method, and it can be difficult to differentiate physiologic cupping from cupping due to glaucoma. Normal eyes with large optic discs will tend to have large cups which can be inaccurately diagnosed as glaucoma, and eyes with small optic discs will tend to have small cups which can be misinterpreted as normal. Also eyes with tilted optic discs, peripapillary atrophy, and myopic degeneration may be difficult to accurately assess. Another limitation of ONH assessment in glaucoma is the poor sensitivity for detecting change over time. Once the visual field defect is moderate to advanced, detection of change with stereo-disc 251-0083C 7

photography is less satisfactory than with visual fields23. ONH changes can also be difficult to detect in early glaucoma. A study by Quigley and colleagues found that in a group of ocular hypertensives who converted to glaucoma, only 19% exhibited ONH changes24. The EMGT study found that only 7% of all 255 patients showed progressive changes in their optic disc during the entire 6 years of follow-up, where 53% were shown to progress by their visual fields25. In general, the sensitivity and specificity values based on ONH assessment are higher than with lop assessment alone. The diagnostic accuracy varies depending on the specific study, however most studies report sensitivity and specificity values in the 70-80% range26-30.much of this variability between studies comes from the differences in the patient's level of glaucomatous damage, as well as how the ONH was assessed. Also, the ONH evaluation in these studies was conducted by highly trained and experienced glaucoma experts using good quality photographs. In a common clinical setting, where the quality of photographs may not be optimal and the clinician may not have the same experience as these experts, the actual sensitivity and specificity values may be lower. Glaucoma Diagnosis: Visual Field Assessment (SAP) In addition to lop and ONH assessment, visual field testing is included in standard clinical examinations. The visual field is generally assessed through standard automated perimetry (SAP). Many clinicians consider the visual field test to be the 'gold standard' for glaucoma diagnosis, and they wait until the visual field shows a defect before diagnosing glaucoma. However, there is strong evidence suggesting that by the time there is a visual field defect on SAP, the disease is already in the moderate to advanced stage24.31-37. Histological studies have found that as many as half of all ganglion cells can be lost before a defectis detectedby the visualfield 31.32. A recentreportfromthe OHTSstudyfoundthat of the ocularhypertensives who converted to glaucoma, only 50% had visual field defects17. Numerous other studies provide strong evidence that structural abnormalities are present before visual field damage is detected with SAp33-37. Another important limitation of visual field testing is the high variability of the results. For exampie, the OHTS study found that 86% of defects detected with SAP were not replicated on repeat 8 251-0083C

testing15. This led the scientists in the study (and many clinicians in their practices), to require that a defect be replicated on a second and/or third follow-up test before the it was confirmed as an actual defect. This policy would push back the detection of the disease even further if a repeatable visual field defect measured by SAP is required for diagnosing glaucoma. More specialized visual field tests such as Short-Wavelength Automated Perimetry (SWAP) and Frequency Doubling Technology (FDT) may be able to detect earlier loss by isolating specific subpopulations of ganglion cells38. However there are limitations associated with these tests as well. For example, SWAP has high variability and is especially difficult for older individuals due in part to the yellowing of the lens with age. Also, all visual functional measures are inherently variable due to the subjective nature of the test. The sensitivity and specificity reported for SAP is generally not as good as expert grading of stereo optic disc photographs. Wang et al. found sensitivity was 70% and specificity was 67% using SAp39. A complicating factor of this, however, is that determining sensitivity and specificity from SAP defects is problematic when defects presented on SAP are the criteria for defining glaucoma (unless the appearance of the optic disc is used to define the disease). In summary, current diagnostic tools have inadequate sensitivity and specificity for glaucoma detection. Furthermore, early glaucoma is often missed if the clinician relies mainly on the visual field and lop. Subjective assessment of the ONH even with stereo-photography has limitations as well, including the requirement of a clear media and dilated pupil and a high level of expertise when evaluating the photographs. Also, accurate glaucoma diagnosis is more difficult with small and large optic discs. Glaucoma Diagnosis: RNFLAssessment RNFLassessment for glaucoma diagnosis and follow-up has several distinct advantages over current diagnostic approaches. It was demonstrated over 30 years ago that RNFL defects are the earliest sign of glaucoma4o. Since then, numerous studies have found that RNFL defects occur prior to visual field loss33-37.a study by Sommer et al.33found that 88% of ocular hypertensives who converted to glaucoma had RNFL defects at the time the visual field defect was detected with SAP. Furthermore, 60% of these converters had RNFL defects present 6 years prior to the visual field defect. 251-0083C 9

There is also evidence that RNFL changes can occur even prior to optic nerve head changes. A study by Quigley et al.24found that RNFL changes are detected more frequently than ONH changes in eyes that converted from ocular hypertension to glaucoma. In a sample of 813 ocular hypertensives followed for over 5 years, they found that of the 37 eyes that developed abnormal visual field tests at the end of the 5 year period, 73% had either a RNFL defect initially or developed one during the follow-up. Progressive RNFL atrophy was observed in 49% of the eyes, while optic disc change was observed in only 19%. Several other studies also found evidence that RNFL evaluation is more sensitive for predicting future visual field loss compared to ONH evaluation, and that the RNFL is a better predictor of damage than C/D rati033,41-44. A study by Airaksinen and Alanko found that RNFL defects developed in 83% of early glaucoma patients, while only 42% developed an abnormal C/D rati041. One method of RNFL assessment is red-free RNFL photography. This method provides highresolution monochromatic images of the RNFL. Focal wedge-shaped defects can often be detected with this technique, however diffuse RNFL loss, which is more common45,is more difficult to detect. Other limitations of red-free RNFL photography include the requirement of a clear media, dilated pupil, skilled photographer, and as in the case with optic disc photography, the results are not immediatelyavailable. Image quality is another important factor. Even with a skilled photographer, it can still be difficult to obtain good quality photographs routinely. Due to these limitations, red-free RNFL photography is used mostly in academic centers and is not commonly used in standard clinical practice. The sensitivity and specificity reported for red-free RNFL photography was found to be slightly higher on average than with ONH assessment. Studies using red-free photography generally find sensitivity and specificity in the range from 70-80% 46-48.Airaksinen et al49 found somewhat higher values, with a sensitivity of 94% and specificity of 83%. In summary, evaluation of the RNFL is important for glaucoma diagnosis as RNFL damage often occurs earlier than can be detected with visual fields and even before optic nerve head damage. Red-free RNFL photography has many advantages, but the subjective interpretation of the resuits and the practical limitations of the method limit its usefulness. 10 251-0083C

'" An objective method to assess the RNFL is through scanning laser polarimetry. The GDx VCC is a scanning laser polarimeter that measures RNFL thickness using polarized Iight50(see Chapter 2 for details). The GDx VCC provides objective RNFL information that is compared to an extensive normative database (see Chapter 3 for details). Comparisons to the database provide the clinician with information regarding the status of the RNFL with respect to a large number of healthy eyes of the same age. Deviations from the normal range are clearly presented, simplifying interpretation. Reproducibility of the GDx VCC has been shown to be excellent51.52,providing the foundation for detection of small changes over time due to progression of the disease. Recent studies also show that the device has excellent diagnostic power. Reus and Lemij recently reported the GDx VCC had a sensitivity of 89% and a specificity of 98%53. Furthermore, Medeiros et al.54found that the GDx VCC was more accurate in detecting glaucoma than expert grading of red-free RNFL photographs. The GDx VCC is also very practical; the exam is very fast and simple. This helps reduce operator influence and eliminates the need for experienced technicians. As RNFL analysis enables the clinician to diagnose glaucoma early, and therefore treat glaucoma early and prevent progression, the GDx VCC will become a key tool for glaucoma diagnosis and management. Summary. Glaucoma is characterized by a loss of retinal ganglion cells and their axons, therefore, assessment of the optic nerve fibers is critical for early detection and monitoring change over time. The current diagnostic tools are inadequate, and more emphasis on RNFL evaluation is needed. RNFL changes precede visual field loss33-37and optic disc changes24.41.considering the difficulty of the clinical examination and the limitations of red-free RNFL photography, a simple and more objective tool for RNFL evaluation is needed. The GDx VCC provides unique, accurate and reproducible RNFL information. It is simple to use and is easy for both the patient and operator. Results are presented in a clear and concise format, simplifying interpretation. However, the GDx VCC is not intended to replace the more traditional methods of a standard clinical examination: measuring lop, assessing the optic disc, and visual field testing. Rather, the GDx VCC should be added to the standard clinical examination to compliment the information from these other methods. When the results of the GDx VCC are combined with the information gained from lop, optic disc assessment, and visual field results, the outcome will be a more accurate assessment of the health of the RNFL. 251-0083C 11