Determination of mercury in wine by vapour generation and atomic spectrofluorimeter (Resolution Oeno 15/2002)

Similar documents
GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF THE

GB Translated English of Chinese Standard: GB NATIONAL STANDARD

Purity Tests for Modified Starches

TOP 7 ACTIVITIES OF CEN AND ISO STANDARDIZATION OF METHODS FOR ANALYSIS OF ANIMAL FEEDS

Application note. Determination of metals in soil by microwave plasma - atomic emission spectrometry (MP-AES) using DTPA extraction.

EXPERIMENT 4 DETERMINATION OF REDUCING SUGARS, TOTAL REDUCING SUGARS, SUCROSE AND STARCH

6.02 Uniformity of Dosage Units

Thiols (mercaptans) in Fuels (ASTM D )

Admixtures for concrete, mortar and grout Test methods Part 12: Determination of the alkali content of admixtures

Pectins. Residue Monograph prepared by the meeting of the Joint FAO/WHO Expert Committee on Food Additives (JECFA), 82 nd meeting 2016

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB1886.

Mercury Determination in Tuna, CRM 463 by USDA Method CLG- MERC1.01 Using the QuickTrace M-7600 CVAAS Mercury Analyzer

Feedstuffs Analysis G-22-1 PROTEIN

INTERNATIONAL ŒNOLOGICAL CODEX. DETERMINATION OF BETA-GLUCANASE (ß 1-3, ß 1-6) ACTIVITY IN ENZYME PREPARATIONS (Oeno 340/2010, Oeno )

METHOD FOR THE DETERMINATION OF - DICARBONYL COMPOUNDS OF WINE BY GC AFTER DERIVATIZATION BY 1,2-DIAMINOBENZENE (OIV-Oeno 386B-2010)

STANDARD OPERATING PROTOCOL (SOP)

Petrolatum. Stage 4, Revision 1. Petrolatum is a purified semi solid mixture of hydrocarbons obtained from petroleum.

Standard Operating Procedure for Chloride and Silica in Lake Water (Lachat Method)

CORESTA RECOMMENDED METHOD N 39

2. is a set of principles intended to help sustain a habitable planet.

3016 Oxidation of ricinoleic acid (from castor oil) with KMnO 4 to azelaic acid

Hydroxypropyl Starch (Tentative)

INTERNATIONAL ŒNOLOGICAL CODEX. PROTEIN PLANT ORIGIN FROM WHEAT, PEAS and POTATOES (OENO 28/2004, ) OIV-OENO OIV-OENO

Selenium, atomic absorption spectrometric, hydride, automated

It is recommended to use titanium coils. ph meter to control ph of the process. It is advised to use an automatic dosage for the maintenance products.

Lutein Esters from Tagetes Erecta

ARTENIMOLUM ARTENIMOL. Adopted revised text for addition to The International Pharmacopoeia

METHOD 8316 ACRYLAMIDE, ACRYLONITRILE AND ACROLEIN BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC)

G/LITRE 5.0 g KOH g 0.5 g 0.05 g 0.01 g MgS047H20 NaCl CaCl2

Analysis of trace elements in nutraceuticals in compliance with USP chapter <2232> Elemental Contaminants in Dietary Supplements

» Monohydrate Citric Acid contains one molecule of water of hydration. It contains not less than 99.5 percent and not more than 100.

Residue Monograph prepared by the meeting of the Joint FAO/WHO Expert Committee on Food Additives (JECFA), 82 nd meeting 2016.

IODINE AFFINITY. 3. Extraction Shells: Paper, 80 x 22 mm (Note 1)

» Croscarmellose Sodium is a cross linked polymer of carboxymethylcellulose sodium.

Experiment 3. Potentiometric Titration Using a ph Electrode. information necessary for both purposes by monitoring the ph of the solution as the

THERMALLY OXIDIZED SOYA BEAN OIL interacted with MONO- and DIGLYCERIDES of FATTY ACIDS

BRIEFING. Nonharmonized attributes: Identification, Heavy metals, Characters, Labeling, Bacterial endotoxins, Sterility, Storage.

Standard Operating Procedure for Total and Dissolved Phosphorous (Lachat Method)

Determination of available nutrients in soil using the Agilent 4200 MP-AES

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

E55A GELATIN, GELLING GRADE Gelatina

Yeast Extracts containing Mannoproteins (Tentative)

Corn Starch Analysis B-47-1 PHOSPHORUS

Dosage of sugars in wine by HPLC (Resolution Oeno 526/2016)

INTERNATIONAL ŒNOLOGICAL CODEX. BENTONITES Bentonita N SIN: 558 (Oeno 11/2003 modified Oeno )

SOUTH AFRICAN NATIONAL STANDARD

MIXED XYLANASE, β-glucanase ENZYME PREPARATION, produced by a strain of HUMICOLA INSOLENS

CORESTA Recommended Method No. 85

Nitrate and Nitrite Key Words: 1. Introduction 1.1. Nature, Mechanism of Action, and Biological Effects (Fig. 1)

This revision also necessitates a change in the table numbering in the test for Organic Impurities.

(Writing model for laboratory note book)

ESS Method 310.2: Phosphorus, Total, Low Level (Persulfate Digestion)

ARTESUNATE TABLETS: Final text for revision of The International Pharmacopoeia (December 2009) ARTESUNATI COMPRESSI ARTESUNATE TABLETS

E17 ETHYLCELLULOSE. Revision 3 Stage 4

Determination of Copper in Green Olives using ICP-OES

GLUCOSE OXIDASE

DRAFT TANZANIA STANDARD

RP- HPLC and Visible Spectrophotometric methods for the Estimation of Meropenem in Pure and Pharmaceutical Formulations

HAGEDORN AND JENSEN TO THE DETER- REDUCING SUGARS. MINATION OF LARGER QUANTITIES OF XIV. AN APPLICATION OF THE METHOD OF

Application Note novaa 800 D. Determination of Macro and Trace Minerals as well as Toxic Trace Metals in Powdered Milk. Challenge.

PAPRIKA EXTRACT SYNONYMS DEFINITION DESCRIPTION FUNCTIONAL USES CHARACTERISTICS

1 out of 8. Residue Monograph prepared by the meeting of the Joint FAO/WHO Expert Committee on Food Additives (JECFA), 86th Meeting 2018 ERYTHROSINE

TENOFOVIR TABLETS: Final text for addition to The International Pharmacopoeia (June 2010)

Method 7.6 Raw sugar: reducing sugars by the Luff Schoorl method

DRAFT PROPOSAL FOR THE INTERNATIONAL PHARMACOPOEIA: CARBAMAZEPINI COMPRESSI - CARBAMAZEPINE TABLETS

THERMALLY OXIDIZED SOYA BEAN OIL

INTERNATIONAL ŒNOLOGICAL CODEX. CARBOXYMETHYLCELLULOSE (cellulose gum) (CMC) INS no. 466 CAS [ ] (OIV-Oeno )

Procine sphingomyelin ELISA Kit

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

EXPERIMENT 3 ENZYMATIC QUANTITATION OF GLUCOSE

10 Sulfaquinoxaline H N O S O. 4-amino-N-quinoxalin-2-ylbenzenesulfonamide C 14 H 12 N 4 O 2 S MW: CAS No.:

DRS RWANDA STANDARD. Bleaching agents Specification. Part 1: Sodium hypochlorite solutions for water. treatment. Second edition.

Determination of 6-Chloropicolinic Acid (6-CPA) in Crops by Liquid Chromatography with Tandem Mass Spectrometry Detection. EPL-BAS Method No.

The Nitrofurantoin Capsules Revision Bulletin supersedes the currently official monograph.

02006B 1 vial 02006B 1 vial Store at -20 C. Lyophilized recombinant IL-2

Human Cytomegalovirus IgM ELISA Kit

CELLULASE from PENICILLIUM FUNICULOSUM

Human Cytomegalovirus Virus (CMV) IgG ELISA Kit

DRAFT EAST AFRICAN STANDARD

Analysis of Micronutrients in Milk by Flame Atomic Absorption Using FAST Flame Sample Automation for Increased Sample Throughput

Official Journal of the European Union. (Non-legislative acts) REGULATIONS

ISOMALT. Stage 4. C 12 H 24 O 11 M r C 12 H 24 O 11, 2H 2 O M r DEFINITION

0620 CHEMISTRY. 0620/23 Paper 2 (Core Theory), maximum raw mark 80

IJRPC 2011, 1(4) Rohan et al. ISSN: INTERNATIONAL JOURNAL OF RESEARCH IN PHARMACY AND CHEMISTRY

CORESTA RECOMMENDED METHOD NÄ 9

SACCHARIDES (Liquid Chromatography)

Total Acid Number in petroleum products by automatic titration

AMYLOGLUCOSIDASE from ASPERGILLUS NIGER, var.

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.

Heparin Sodium ヘパリンナトリウム

CYCLOSERINI CAPSULAE - CYCLOSERINE CAPSULES (AUGUST 2015)

EUROPEAN QUALIFYING EXAMINATION 2006

National Standard of the People s Republic of China. National food safety standard. Determination of pantothenic acid in foods for infants and

Most of the ethanol that is used as a biofuel in this country is produced from corn.

COMMON BARBERRY FOR HOMOEOPATHIC PREPARATIONS BERBERIS VULGARIS FOR HOMOEOPATHIC PREPARATIONS

Simultaneous estimation of Metformin HCl and Sitagliptin in drug substance and drug products by RP-HPLC method

CORESTA RECOMMENDED METHOD N 8

Supporting Information File S2

Supporting information for the manuscript

4. Determination of fat content (AOAC, 2000) Reagents

Transcription:

Method OIV-MA-AS323-06 Type IV method Determination of mercury in wine by vapour generation and atomic spectrofluorimeter (Resolution Oeno 15/2002) 1. FIELD OF APPLICATION This method applies to the analysis of mercury in wines with a concentration range between 0 to 10 ug/l. 2. DESCRIPTION OF TECHNIQUE 2.1. Principle of the method 2.1.1 Mineralisation of wine takes place in an acid environment: heating under reflux; mineralisation is achieved with a potassium permanganate. 2.1.2. Reduction of non-consumed permanganate by hydroxylamine hydrochlorate 2.1.3. Reduction in mercury II (metal mercury by stannous chloride (II). 2.1.4. Mercury pick up by an argon current at ambient temperature 2.1.5. Dosage of mercury in monoatomic vapour state by atomic flourescence spectometre with wavelength of 254 nm. Mercury atoms are excited by a mercury vapour lamp; the atoms thus excited emit a radiation called flourescent which allows the quantification of mercury present using a photonics detector to obtain good linearity while eliminating memory effects. 2.2 Principle of analysis (figure 1) The peristaltic pump absorbs the stannous chloride solution, the blank solution (demineralised water containing 1% nitric acid) and the sample of mineralised wine. The mercury metal is taken up in a gas-liquid separator by a current of argon. After going through a drying tube, the mercury is detected by florescence. Then, the gaseous current goes through a permanganate potassium solution in order to capture the mercury. OIV-MA-AS323-06 : R2009 1

Peristaltic peristaltic pump perist Stannous peristaltic chloride c Air Blank Reference or Sample Stannous Valve chloride open Upon sample position Argon flowmeter Hygroscopic membrane Towards sink Gas-liquid separator Florescence detector Analytic Chain for dosage of mercury 3. REAGENTS AND PREPARATION OF REACTIVE SOLUTIONS 3.1 Ultra-pure demineralised water 3.2 Ultra-pure 65% nitric acid 3.3 White: demineralised water (3.1) containing 1% of nitric acid (3.2) 3.4 Nitric acid solution 5.6 M (3.1): Put 400 ml of nitric acid (3.2) into a 1000 ml flask; fill with demineralised water (3.1). 3.5 Sulphuric acid (d= 1.84) 3.6 Sulphuric acid solution 9M: Put 200 ml of demineralised water (3.1), 50 g of potassium permanganate (3.7) into a 1000 ml flask; fill with demineralised water (3.1). 3.7 Potassium permanganate KMnO4 3.8 5% Potassium permanganate solution: Dissolve 50 g of potassium permanganate (3.7) with demineralised water (3.1), in a 1000 ml flask. Fill with demineralised water (3.1). 3.9 Hydroxylamine hydrogen chloride NH2OH, HCl 3.10 Reducing solution: OIV-MA-AS323-06 : R2009 2

Weigh 12g of hydroxylamine hydrogen chloride (3.9) and dissolve in 100 ml of demineralised water (3.1). 3.11 Stannous chloride (SnCl2, 2 H2O) 3.12 Concentrated hydrochloric acid 3.13 Stannous chloride solution: Weigh 40 g of stannous chloride (3.11) and dissolve in 50 ml of hydrochloric acid (3.12). Fill with 200 ml of demineralised water (3.1). 3.14 Mercury standard solution at 1g/l prepared by dissolving 1708 g of Hg (NO 3 ). H 2 O in an aqueous nitric acid solution at 12% prepared from metal mercury. 3.15 Reference mercury solution at 10 mg/l : Place 1 ml of mercury standard solution (3.14) in a 100 ml volumetric flask, add 5 ml of nitric acid, fill will demineralised water (3.1) 3.16 Mercury solution at 50 mg/l: Place 1 ml of 10 mg/l (3.15) solution in a 200 ml flask. Add 2 ml of nitric acid (3.2). Fill with demineralised water (3.1). 4. APPARATUS 4.1 Glass ware 4.1.1 Volumetric flasks 100, 200, and 1000 ml (class A) 4.1.2 Volumetric pipette 0.5,1.0, 2.0, 5, 10 and 20 ml (class A) 4.1.3 Precautionary action: Before using, the glass ware must be washed with 10% nitric acid, leave in contact 24 hours, then rinse with demineralised water. 4.2 Mineralisation apparatus (figure 2) 4.3 Temperature controlled heating mantle 4.4 Squeeze pump 4.5 Cold vapour generator 4.5.1 Liquid gas separator 4.6 Desiccant (Hygroscopic membrane) covered by an air current (supplied from a compressor) and placed before the detector 4.7 Spectrofluorimeter OIV-MA-AS323-06 : R2009 3

4.7.1 Mercury vapour lamp regulated to 254 nm wave length 4.7.2 Atomic fluorescence specific detector 4.8 Computer 4.8.1 Software which regulates the parameters of the vapour generator and the atomic fluorescence detector and enables calibration and usage of the results. 4.8.2 Printer which stores results 4.9 Neutral gas bottle (argon) 5. PREPARATION OF CALLIBRATION SOLUTIONS AND SAMPLES 5.1 SET OF CALLIBRATION SOLUTIONS: 0; 0.25; 0.5; and 1.0 ug/l Introduce : 0; 0.5; and 1.0 and 2.0 ml of the mercury solution to 50 ug/l (3.16.) in 4 100 ml flasks; add 1 % nitric acid (3.2.); fill with demineralised water (3.1.). 5.2. Preparation of samples (figure 2) Wine is mineralised in a glass pyrex apparatus made up of three parts joined by spherical honing: a 250 ml balloon, a vapour recuperation chamber, a refrigerant. Using a pipette put 20 ml of wine in a 250 ml reaction flask; assemble the mineralisation apparatus. Add 5 ml of sulphuric acid (3.6.) and 10 ml of nitric acid (3.4.) slowly; leave overnight. Heat slowly under reflux until the nitrous vapours disappear ; leave to cool. Recover the condensed vapours in the reaction flask. Rinse the recipient with demineralised water. Pour the contents of the reaction flask into a 100 ml volumetric flask. Add potassium permanganate solution (3.8.) until the colour remains. Solubilize the precipitate (MnO 2 ) with a reducing solution (3.10.). Fill with demineralised water (3.1.). Carry out a blank test on demineralised water. OIV-MA-AS323-06 : R2009 4

Refrigerant with balls Circulation cold water Vapour Recuperation chamber Introduction of wine and reagents Reaction Balloon (wine + sulphuric acid + nitric acid) Heating mantle Mineralisation apparatus 6. OPERATING PROCEDURE 6.1 Analytical measurement Turn on the fluorimeter; the apparatus is stable after 15 minutes. The squeeze pump absorbs the white (3.3), the stannous lead II (3.13) and the sample calibrations (5.1) or (5.2.) Verify that bubbling occurs in the liquid gas separator. Present the calibration samples successively (5.1); set off the vapour generator program. The computer software establishes a calibration curve (percentage of fluorescence according to concentration of mercury ug/l). Then present the samples (5.2). 6.2 Automatic checks A blank analysis and a calibration are analysed every five tests to correct any possible spectrofluorimeter derivitives. OIV-MA-AS323-06 : R2009 5

7. EXPRESSION OF RESULTS Results are provided by the computer software and expressed in ug/l. Deduct the mercury concentration in wine in ug/l keeping into account 1/5 dilution. 8. CHECKING RESULTS Quality control is carried out by placing reference material in which the mercury content is known, following the set of calibrations and every 5 samples. Following the analytical series, the reference material is red wine, dry white wine or sweet white wine. The check card is set for each reference material used. The check limits are set at: +/- 2S R intra (2S R intra : reproducibility spread-type) The uncertainly calculation, carried out on check cards, resulted in a red wine reference of: 3.4 +/- 0.8 ug/l and for reference dry white wine : 2.8+/-0.9 ug/l. 9. BIBLIOGRAPHY CAYROL M., BRUN S., 1975. Dosage du mercure dans les vins. Feuillet Vert de l O.I.V. n 371. REVUELTA D., GOMEZ R., BARDON A., 1976. Dosage du mercure dans le vin par la méthode des vapeurs froides et spectrométrie d absorption atomique. Feuillet Vert de l O.I.V. n 494. CACHO J., CASTELLS J.E., 1989. Determination of mercury in wine by flameless atomic absorption spectrophotometry. Atomic Spectroscopy, vol. 10, n 3. STOCKWELL P.B., CORNS W.T., 1993. The role of atomic fluorescence spectrometry in the automatic environmental monitoring of trace element analysis. Journal of Automatic Chemistry, vol. 15, n 3, p 79-84. SANJUAN J., COSSA D., 1993. Dosage automatique du mercure total dans les organismes marins par fluorescence atomique. IFREMER, Rapport d activité. AFNOR, 1997. Dosage du mercure total dans les eaux par spectrométrie de fluorescence atomique. XPT 90-113-2. GAYE J., MEDINA B., 1998. Dosage du mercure dans le vin par analyse en flux continu et spectrofluorimétrie. Feuillet Vert de l O.I.V. n 1070. OIV-MA-AS323-06 : R2009 6