Fibrlok II 2529 Universal Optical Fiber Splice

Similar documents
Fibrlok II 2529 Universal Optical Fiber Splice

Instructions. Fibrlok II Optical Fiber Splicing System. Issue 1, June 1992

Instructions. Fibrlok Optical Fiber Splicing System. Issue 6, August 1991

C200 bands are available in a variety of colors. Visit us at LifeTrakUSA.com

3M Four Wall Header.100 x.100 Low Profile, SMT Straight, Straight and Rt Angle Through-Hole D2500 Series

Mass Fusion Splicing of Optical Fiber Ribbon Cables

How to Use ENBREL : Vial Adapter Method

Blood Glucose Monitoring System. User Guide

PCR Starter Kit. For 96-well blocks, 0.2 ml USER GUIDE USER GUIDE. Part. No. A24829 Revison B

OPTICAL FIBER SPLICING. Courtesy from Significant Technologies Sdn Bhd

Ribbon Splitting Tool (RST-000)

Quick Start Guide. Venipuncture and Intramuscular Injection Training Arm

PCR Starter Kit. For 3 32-well blocks, 0.2 ml USER GUIDE USER GUIDE. Part. No Revison B

Thank you for purchasing the AB COASTER. Our customer service staff is ready to help and to answer any questions.

USER MANUAL Rev. 1.15

PRO-V IDS Kit. Bisco. Instructions for Use. Provisional Restorative System

weight.detach/bench ITEM NO: 76310

Assembly Instruction for Fiber Optic Series FOH Fischer Connectors

Instructions for Use Reprocessed ENDOPATH XCEL Bladeless Endoscopic Trocars and Cannulas. Reprocessed Device for Single Use.

LET OUR IMAGE ENHANCE YOUR IMAGE. Operating Instructions MedRx Video Portable OtoScope System

USER S MANUAL QUESTIONS? CAUTION. For a great selection of new CD and MP3 workouts. Visit our website at. or call

Product Specifications and Usage Information P4405, P4410, & P4420 Genesys 30 Dosimeter Holder System

USER S MANUAL QUESTIONS? CAUTION. Visit our website at.

How To Get The Most Out of Your StarSet Headset

COR. Precision Targeting Cartilage Repair System. Arthroscopic Technique for Repair of Osteochondral Defects

VISTA400 REMOVABLE FOOT PLATE. Instructions For Use. Step on yellow pedals to close and open legs to go around chairs & ambulate.

User Bulletin 7500 Fast Precision Plate Holder for MicroAmp Tube Strips

3M MS 2. Next Generation Modular Splicing Rigs and Maintenance Kits. Simplified Systems For All Your Multi-Pair Splicing Needs

Product Information Packet

Quick Start Guide. Congratulations on your journey to better hearing

Cardiva Catalyst III INSTRUCTIONS FOR USE

Bryan-Dumon Series II Rigid Bronchoscope and Stent Placement Kit USER MANUAL

INSTRUCTIONS FOR USE TYMLOS (tim lows ) (abaloparatide) injection, for subcutaneous use

Quick Start Guide. Congratulations on your journey to better hearing

USER S MANUAL QUESTIONS? CAUTION. Visit our website at. new products, prizes, fitness tips, and much more!

Instructions for Use Enbrel (en-brel) (etanercept) for injection, for subcutaneous use Multiple-dose Vial

IMPORTANT SAFETY INSTRUCTIONS

Radux StandTall Instructions for Use Sheath Extender and Securement Clasp

A-dec 372L or 572L Dental Light on an A-dec Performer Dental Chair INSTALLATION GUIDE

Quick Start Guide. Congratulations on your journey to better hearing

VeriFit Irritant Smoke Generators for Respirator Fit Testing SENSITIVITY CHECK PROTOCOL. Introduction. Warnings

SelectTech 3.1 Bench Assembly / Owner s Manual

OWNER S MANUAL. Quick Insertion Guide: INSERT EARTIP into ear canal and rotate earpiece backwards & into position CHECK FOR SEAL

2. Before Testing Monitor Checker Test...10 Inserting Lancets into Lancing Device...11 Quality Control Testing...13

`bob`=å~ãéê~=ó=å~êéi=åäé~åáåöi= ÇáëáåÑÉÅíáçå=~åÇ=ëíÉêáäáò~íáçå

MARCY DIAMOND ELITE UTILITY BENCH MD-440. Model MD-440. Retain This Manual for Reference OWNER'S MANUAL

System. User Manual for Self-Testing

E. SelectTech 5.1 Bench Owner s / Assembly Manual

Protn-Latex. For Determination of Protein in Latex. (Cat. # Latex, Latex) think proteins! think G-Biosciences

Align Gluco-Monitoring System (BG1) Quick Start Guide

MATERIAL SAFETY DATA SHEET WILKINSONS GROUT CLEANER

Align Gluco-Monitoring System (BG1) Quick Start Guide

Activated Transponder & Activator Instruction Manual

USER S MANUAL QUESTIONS? CAUTION. Visit our website at. For a great selection of new CD and MP3 workouts. or call

EVER Pharma D-mine Pen Pen injector for Apomorphine 10 mg/ml

CoaguChek S System. Quick Reference Guide. This is a CLIA-waived System. Coagulation Testing with Fresh Whole Blood

Instructions for Use Reprocessed Ethicon ENDOPATH XCEL TM Bladeless Trocar with OPTIVIEW Technology

COMPRESSOR NEBULIZER MODEL: JB USER S MANUAL

INSTRUCTIONS FOR PREPARING AND GIVING AN INJECTION OF ENBREL POWDER

Home Health Foundation, Inc. To create more permanent IV access for patients undergoing long term IV therapy.

HumaPen LUXURA HD INSULIN DELIVERY DEVICE INSTRUCTIONS FOR USE

Sharps Container (not included) 1 Gather and check supplies. Gather supplies

Thank you for purchasing the AB COASTER. Our customer service staff is ready to help and to answer any questions.

Correction System. Surgical Technique

THE TOTALLY WICKED TORNADO NC CONGRATULATIONS ON PURCHASING YOUR TOTALLY WICKED TORNADO NC ELECTRONIC CIGARETTE KIT

E. SelectTech 3.1 Bench Assembly / Owner s Manual

Instructions for Use. For use with. 10 mg vial

Multipower. User Guide E S S E N T I A L S T R E N G T H

Owner s Manual & Exercise Guide

English. Fealite Nasal Pillows System. User Manual

Autopen 24 is an easy to use insulin injection pen, designed for use with 3.0ml sanofi aventis insulin cartridges. Compatible with all pen needles*.

HumaPen SAVVIO INSULIN DELIVERY DEVICE INSTRUCTIONS FOR USE

QUALITATIVE FIT TEST APPARATUS

SelectTech 4.1 Bench Assembly / Owner s Manual

Neckmike Mobile User Guide Neckmike USA. Table of Contents

Pure 312 Nx, Pure 13 Nx

Instructions for Use Enbrel (en-brel) (etanercept) Single-use Prefilled SureClick Autoinjector

INSTALLATION MANUAL. VIDEO Camera, Probe and Lightsource OTOSCOPES.

WEIGHT BENCH EXERCISER User s Manual

WEIGHT SYSTEM EXERCISER User s Manual

ESTABLISHED IN They re quick, easy and safe! METH-1 Drug Detection Ampules OPERATING INSTRUCTIONS. tttt

Instructions for Use Neulasta (nu-las-tah) (pegfilgrastim) Injection, for subcutaneous use Single-Dose Prefilled Syringe. Plunger rod Used plunger rod

SAFETY LABELS CAUTION: PINCH POINT. Make sure locking pin is fully engaged before beginning forward and side lift exercises.

Instructions for Use. Welcome!

TABLE OF CONTENTS 1.1. WARRANTY DAMAGED SHIPMENTS SERVICE INTRODUCTION UNPACKING AND INSTALLATION

Mouse Leptin ELISA Kit Instructions

Tetracycline Plate Kit (for Honey) PN 52254B

Midwest E Motor. Directions For Use. Doc. No

Pollen Slide Mounting Protocol

BLOOD COLLECTION GUIDELINES

POWER STATION With Fold up Bench

Perform extraction for finished product, rinse water or swab. Transfer 12 drops of extract to incubation vial.

Product Guide for LudgerSep TM R1 HPLC Column for DMB labelled Sialic Acid Analysis

Installation and Maintenance Instructions

Transcription:

Fibrlok II 2529 Universal Optical Fiber Splice Instructions January 2007 78-8128-0163-3-E

Contents: 1.0 General... 3 2.0 Splicing Set-up... 4 3.0 Fiber Preparation... 5 4.0 Splice Assembly... 6 5.0 For splicing any combination of 250 µm coated fiber and 900 µm buffered fiber:... 8 6.0 Fiber Repositioning... 10 7.0 Fiber Organization and Splice Storage... 11 8.0 Splicing Accessories... 12 2 78-8128-0163-3-E

1.0 General 1.1 The 3M Fibrlok II Universal Optical Fiber Splice 2529 provides permanent mechanical splices for single- or multimode fiber having 125 µm diameter cladding. The 2529 universal splice is designed to accommodate any combination of fibers with coating diameters from 250 µm to 900 µm. 1.2 All 2529 splices are gray in color and are marked with the 3M Fibrlok II logo on the splice cap. Cap.150" (3.8 mm) 1.50" (38.1 mm) 0.250" (6.4 mm) End Plug (each end) Fiber Entry Port (each end) Jacket 1.3 3M Fibrlok Assembly Tool 2501 Pivoted Handle (shown open) Toggle Arm Splice Holding Cradle Fiber Alignment Guides (2) Toggle Arm Fiber Retention Pad Fiber Retention Pad Finger Cutout Mounting Holes (4) Instruction Label (2) Base Fiber Cleave Length Gauge (both ends of tool) 78-8128-0163-3-E 3

1.4 Tools and Materials Required are as follows: 3M Fibrlok Assembly Tool 2501 Plastic Coating (Buffer) Stripper Reagent Grade Isopropyl Alcohol Lint-free Wipes Cleaver 3M Fibrlok II Video Instructions (optional) 3M Fibrlok Tool Kit (optional) 1.5 Some Compatible 3M Organizers are: 3M 2522, 3M 2524-A, 3M 2523 3M 2527 CAUTION May cause minimal eye irritation. Contains: Phenylmethyl silicone (63148-58-3), hydrophobic silica (68611-44-9). Precautions: Avoid eye contact. Wash hands before eating or smoking. First Aid: Eye Contact: Immediately flush eyes with plenty of water while holding eyelids open and continue flushing for ten minutes. Call a physician. Skin Contact: Wash with soap and water. Production Information Source: Material Safety Data Sheet or 3M Company, St. Paul, MN 55144-1000, (612) 733-111-: Operator 55 2.0 Splicing Set-Up 2.1 The splicing area should be clean, dry and well-lit. A clean, well-organized splicing area will improve splice efficiency and minimize the risk of contamination of fibers or splices. 2.2 Open the buffer tubes, expose and clean the fibers per your company practice. Storage, use and disposal of isopropyl alcohol should be per your company health, safety and environmental instructions. Refer to solvent label or Material Safety Data Sheet. 2.3 See Section 6.0 for recommended procedures for fiber organization and splice storage. 2.4 Remove Fibrlok splice from protective package. Load the splice into the assembly tool by pressing firmly at the ends of the splice. Carefully follow health, safety and environmental information on Fibrlok II splice label or Material Safety Data Sheet. 4 78-8128-0163-3-E

2.5 If using the 3M Fibrlok Assembly Tool, 2501 rotate the toggle arms for the appropriate fiber size. Inward 250 µm Outward 900 µm 3.0 Fiber Preparation 3.1 Remove the minimum length of fiber required to prepare and splice the fibers. 3.2 Strip approximately 1 to 2 inches (25 mm to 51 mm) of plastic coating from the fiber using a mechanical stripper. The stripper should be in good operating condition to prevent scratches or other damage to the glass cladding. 1" to 2" (25 mm - 51 mm) 3.3 Clean the bare glass by pulling the fiber through an alcohol soaked lint-free wipe. This will remove any fragments or dirt remaining on the fiber. Do not wipe the fibers more than two times, and limit the time that the bare fiber is exposed to the atmosphere. Carefully follow health, safety and environmental information on container label or Material Data Sheet for isopropyl alcohol being used. 3.4 Cleave fiber to 12.5 mm ±0.5 mm (0.492 ±0.020 inches). Important: The Fibrlok II Universal Splice 2529 uses a cleave length of 12.5 mm ±0.5 mm (0.492 ±0.020 inches) for both 250 µm and 900 µm coated fibers. The cleaver should be in good operating condition and used in accordance with the manufacturer's instructions. It is recommended that the cleaver provide a consistent cleave-to-coating length within ±0.5 mm. In addition, standard cleavers should produce cleaved ends within 2 of perpendicular and free of major defects. Cleavers specifically designed to produce controlled, angled cleaves of greater than 2, but not more than 6, may also be used with the Fibrlok II optical splice. 78-8128-0163-3-E 5

3.5 Check the cleave length using the 12.5 mm cleave length gauges on the 3M Fibrlok Assembly Tool. Adjust the cleaver to provide the prescribed cleave lengths. Check cleave lengths periodically during subsequent splicing operations. Do not allow cleaved end to contact tool. Do not clean the fibers again after they have been cleaved. 250 µm 900 µm 250 µm : 12.5 mm 900 µm : 14.0 mm 900 µm : 12.5 mm 4.0 Splice Assembly 4.1 Push the fiber down into the fiber retention pad on the proper side of the splice. Hold the coated portion of the fiber ONLY. Do not allow the cleaved end to contact any surface before insertion into the splice. 4.2 Grasp the coated fiber about.25 inches (6 mm) from the bare glass and move the fiber end onto the fiber alignment guide on the assembly tool such that the end is resting on the alignment guide outside of the splice. When splicing 250 µm to 900 µm coated fiber, always insert the 250 µm coated fiber first. Fiber should be placed in the retention pad and inserted into the splice immediately following cleaning to minimize exposure to the atmosphere and reduce the risk of contamination. Push fiber straight into fiber alignment guide, NOT AT AN ANGLE. 4.3 Gently continue pushing the fiber into the splice until resistance is felt. When fully inserted, the first fiber should be straight or have a slight bow up to.1 inch (3 mm). If properly inserted, bare glass should not be visible outside of splice. If bare glass is visible, pull back slightly on fiber and continue insertion until resistance is met. Never fully remove fibers from splice after initial insertion. Do not pull on fiber after it has been properly inserted. 6 78-8128-0163-3-E

4.4 Prepare second fiber (strip, clean and cleave) as described in Section 3. 4.5 Lay fiber into foam retention pad and begin to insert the fiber end into the splice, as in 4.01 and 4.02. 4.6 Gently push the second fiber in small increments straight through the alignment guide into the fiber entry port. As the coating of the second fiber enters the fiber entry port, watch for the bow in the first fiber to increase. This occurs when the end face of the second fiber contacts the first fiber and pushes the first fiber slightly back out of the splice. Continue gently pushing the second fiber until it meets resistance. 4.7 Following proper insertion, the second fiber will be approximately straight, but may have up to a.1 inch (3 mm) maximum bow. At this point, the first fiber will have a larger bow than the second fiber and larger than it had initially. 4.8 Push the first fiber back against the second fiber until there are equal bows in both fibers. Do not pull on either of the fibers following establishment of the bows in the first and second fibers. The fiber ends must be held together by the compressive forces induced by the bows to produce a low loss splice. If fiber bows are NOT observed to move as described, repeat steps 4.02 4.07 of Splice Assembly but DO NOT fully remove fibers from the splice. If bow movement is still not observed, remove fibers, strip, clean and recleave, checking for proper cleave length. Re-splice per splicing procedure using a new splice. Do not attempt to tune or optimize the splice as this may result in higher splice loss. The 3M Fibrlok II Splice is not designed to be tuned. Fiber alignment does not occur until the splice is activated. 4.9 Pivot the handle of the Fibrlok assembly tool down until it contacts the cap of the Fibrlok splice. Squeeze the handle of the assembly tool as shown in order to close cap and actuate the splice. When possible, secure the tool to a work surface for added support. A snap sound will be heard when the splice is actuated. 78-8128-0163-3-E 7

4.10 Remove the 3M Fibrlok Splice from the assembly tool by first removing the fibers from the foam retention pads and then lifting the splice from the splice holding cradle. In the event a splice must be refabricated, simply cut the fibers at each end of the splice (this will remove 1-1/2" of fiber from the loop) and re-splice per instructions. Splice fabrication will require a new splice and a length of 2 inches on each fiber. Do not remove fibers and re-use Fibrlok splices. 5.0 For splicing any combination of 250 µm coated fiber and 900 µm buffered fiber: 5.1 Keep Fibrlok splices clean. Do not remove splices from sealed cavity until ready to use. 5.2 Place Fibrlok splice into splice holding cradle in assembly tool. 5.3 If using the 3M Fibrlok Assembly Tool 2501, be sure that the retention pad toggle arms are in the inward position for 250 µm fibers and in the outward position for splicing 900 µm fibers. 5.4 Strip and cleave first fiber to 12.5 mm ± 0.5 mm (0.492 ± 0.20 in). 5.5 Taking care not to touch fiber end face, place fiber into foam retention pad. 8 78-8128-0163-3-E

5.6 Insert first fiber into the end port until coating bottoms out. If splicing 250 µm coated fiber to 900 µm buffered fiber. 5.7 Strip and cleave second fiber to 12.5 mm ± 0.5 mm (0.492 ± 0.020 in). 5.8 Taking care not to touch fiber end face, place second fiber into the other foam retention pad. 5.9 Insert second fiber into the other end port of splice until it contacts the first fiber. 5.10 Push the first fiber back against the second until there are equal bowls of approximately 5 to 8 mm (0.2 to 0.3 inches) in both fibers. 5.11 Push down the assembly tool handle until splice cap snaps closed. 5.12 Lift handle, remove the fibers from the foam retention pads, and remove completed splice from the tool. 78-8128-0163-3-E 9

6.0 Fiber Repositioning 6.1 If high loss is observed after splice has been actuated, it is possible that the fiber ends are separated. In this case, lift the splice cap and reposition fiber ends, as instructed below. Do not completely remove fiber from Fibrlok splices. 6.2 While the splice is in the splice holding cradle, insert the short prongs of the 3M Fibrlok II Splice cap lifter into the two holes on the side of the splice. The cap lifter will be at an angle to the splice. The long prongs will be resting against the top of the splice cap. 6.3 Slide the bottom of the cap lifter inward until it is in a vertical position, lifting the splice slightly out of the cradle. 6.4 Hold the cap lifter in place with one hand and push down on the ends of the splice with the other hand. This action should reseat the splice into the holding cradle and lift the cap at the same time. 6.5 Repeat fiber centering and splice actuation (See step 4.06 4.09.) If after two attempts an acceptable splice loss is not obtained, remove fiber, strip, clean and re-cleave. Resplice using a new splice. 10 78-8128-0163-3-E

7.0 Fiber Organization and Splice Storage 7.1 When storing fiber slack in a splice tray, the spliced fiber ends will twist one full turn for each full loop of fiber being stored. This rotation places stress on the fibers. This rotational stress makes fiber organization more difficult and may affect fiber/splice performance, particularly in 900 µm coated fibers. The stiffness of the 900 µm fiber does not distribute this stress in the same manner as 250 µm coated fiber. The following procedure must be followed when splicing 900 µm coated fibers and will improve fiber organization when splicing all fiber types. 7.2 Secure the buffer tubes of the fibers to be spliced to the tray so that the fibers are free to rotate through the point of attachment. 7.3 Select the first two fibers to be spliced and lay them into the tray. Trim the fibers so they are the right length for splicing plus approximately 1 to 2 inches (2.5 to 5 cm) for fiber end preparation. 7.4 Place the splice assembly tool close to or on top of the splice tray. Match the orientation of the tool to that of the splice holder or tray whenever possible. 7.5 Remove the minimum amount of fiber required for fiber preparation and splicing. Remove less than one loop if possible. 7.6 Prepare fibers and complete splice as described in Section 3 and 4. 7.7 Carefully lay the splice on top of the holder without securing the splice into the holder. 78-8128-0163-3-E 11

In order to minimize torsion on the fiber, perform the following: 7.8 For 250 to 250 µm and 900 to 900 µm splices: a. Store the shorter of the two fibers in the tray. b. Observe how the splice lays in its relaxed state. Rotate the splice through the smallest possible angle to install it in the tray. c. Store the second fiber. 7.9 For 250 to 900 µm splices: a. Store the 900 µm fiber first. b. Grasping the splice by the 900 µm fiber, observe how the splice lays in its relaxed state. Rotate the splice through the smallest possible angle to install it in the tray. c. Store the 250 µm fiber. 8.0 Splicing Accessories 8.1 The 3M Fibrlok Splice Organizer Tray 2523 holds up to 24 Fibrlok splices and provides superior fiber and splice organization. Easily installed, the tray will accommodate up to eight buffer tubes holding up to 48 fibers (250 µm or 900 µm coated fibers) and can be adapted for fusion splice storage. 8.2 The 2524 splice tray fits and mounts into the 3M Fiber Optic Splice Closure and the 3M Fiber Optic Splice Case 2178. It is also compatible with a variety of non-3m closures. 8.3 3M Fibrlok Splice Kits provide all the tools necessary for the assembly of the Fibrlok splice. Fibrlok splice kits are available with or without a fiber optic cleaver. 12 78-8128-0163-3-E

3M Fibrlok Splice Kits: 3M Stock Number 2559 Splice Kit...80-6113-2375-1 2559-C Splice Kit with 2534 Cleaver...80-6113-2376-9 Splice Kit Components (available separately) 2501 Assembly Tool...80-6105-8187-0 6365-ST Stripping Tool...80-6113-0460-3 Kevlar Snips...80-6113-0462-9 Cleaning Alcohol Bottle...80-6104-4329-5 Lint Free Cloth (100/pkg.)...80-6104-4324-6 Instruction Manual... 78-8128-0163-3-E 2534 Cleaver...80-6113-2377-7 78-8128-0163-3-E 13

3M and Fibrlok are trademarks of 3M Company. Important Notice All statements, technical information, and recommendations related to 3M s products are based on information believed to be reliable, but the accuracy or completeness is not guaranteed. Before using this product, you must evaluate it and determine if it is suitable for your intended application. You assume all risks and liability associated with such use. Any statements related to the product which are not contained in 3M s current publications, or any contrary statements contained on your purchase order shall have no force or effect unless expressly agreed upon, in writing, by an authorized officer of 3M. Warranty; Limited Remedy; Limited Liability. This product will be free from defects in material and manufacture for a period of one (1) year from the time of purchase. 3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. If this product is defective within the warranty period stated above, your exclusive remedy shall be, at 3M s option, to replace or repair the 3M product or refund the purchase price of the 3M product. Except where prohibited by law, 3M will not be liable for any indirect, special, incidental or consequential loss or damage arising from this 3M product, regardless of the legal theory asserted. 3 Communication Markets Division 3M Telecommunications 6801 River Place Blvd. Austin, TX 78726-9000 800.426.8688 Fax 800.626.0329 www.3mtelecommunications.com Please recycle Litho in USA 3M 2007 78-8128-0163-3-E