D-RAD SMART PACK Plating System. A series of case studies

Similar documents
Knee spanning solutions

EVOS MINI with IM Nailing

Surgical Technique. CONQUEST FN Femoral Neck Fracture System

Surgical Technique. Distal Humerus Locking Plate

Increasing surgical freedom Restoring patient function

Surgical Technique. Olecranon Locking Plate

Technique Guide. 2.4 mm Variable Angle LCP Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology.

Surgical Technique. Calcaneal Locking Plate

Surgical Technique. Anterolateral and Medial Distal Tibia Locking Plates

DVR Crosslock Distal Radius Plating System. Product Brochure

Surgical Technique. Clavicle Locking Plate

Knee Surgical Technique

Surgical Technique. Distal Radius and Foot

The NBX Non-Bridging External Fixator A Non-Bridging External Fixator/Locking Plate capturing a series of.062mm K-wires and 3mm half-pins that are

Distal radius fracture Golden standard and breaking news

Trauma fixation choices chart your fracture

Surgical Technique Guide

Surgical Technique. Proximal Humerus Locking Plate

Surgical Technique. 3.5mm and 4.5mm Lateral Proximal Tibia Locking Plates

Disclosures. Distal Radius Fractures 5/16/2017. Distal Radius Fractures: Complications & Limitations of the Volar Approach

Surgical Technique International Version. Clavicle Locking Plate

6/5/2018. DISCLOSURES Hassan R. Mir, MD, MBA, FACS. Evolution of Distal Radius Fracture Treatment [Chung Hand Clinics 2012]

Surgical Technique. Targeter Systems Overview

Hand Fracture System with Small Bone External Fixation System. Product Overview

Wrist Fixation System

QUICK REFERENCE GUIDE. The Pennig Dynamic Wrist Fixator. Part A: Trans-articular application

Mark VanDer Kaag 1, Ajmal Ikram 2. Hand Unit, Tygerberg Hospital University of Stellenbosch

Forearm Fracture Solutions. Product Overview

Conventus CAGE PH Surgical Techniques

SMV Scientific Bone Plate and Screw System Surgical Technique

Visualize, stabilize, mobilize. Wristore * Distal Radius Fracture Fixator Abbreviated Surgical Technique

ORTHOLOC 3Di. Foot Reconstruction System SURGIC AL TECHNIQUE

AcUMEDr. Arc Wrist Tower. For Wrist Arthroscopy And Fracture Reduction

LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation.

Technique Guide. LCP Proximal Femoral Hook Plate 4.5/5.0. Part of the LCP Periarticular Plating System.

Acutrak 2 Headless Compression Screw System Micro, Mini, and Standard Screws. Supplemental Use Guide Four Corner Fusion

A sequenced approach to flush graft placement. GLENOID BONE LOSS SYSTEM Procedural Solution

MICRONAIL. Intramedullary Distal Radius System SURGICAL TECHNIQUE

Complications of Distal Radius Fractures. How to Treat a Distal Radius Fx 11/13/2017. Michael S. Bednar, M.D. Loyola University Chicago

Surgical Technique International Version

A Patient s Guide to Adult Distal Radius (Wrist) Fractures

Instrument and Implant for wrist fracture

ANATOMIC LOCKED PLATING SYSTEM

Flower Opening Wedge Plate

Anatomic Talus Plate Module

The Flower Proximal Humerus Plate

Distal Radius and Distal Ulna Plates System Self-Tapping Spherical Locking Screw Self-Tapping Conical Locking Screw Cortex Screw

Index. Note: Page numbers of article titles are in boldface type. Hand Clin 21 (2005)

A Patient s Guide to Adult Forearm Fractures

The Flower Four Corner Fusion Plate

Acu-Loc Wrist Spanning Plate System. Surgical Technique

Distal Ulnar Locking Plate

Orthopedics in Motion Tristan Hartzell, MD January 27, 2016

Ultrasound-guided reduction of distal radius fractures

Cost and Time Considerations: Are Minifragment Plates Worth It? Disclosure. More Disclosures. Are minifragment plates worth it? it depends!

Acomparison of percutaneous and pin-and-plaster techniques in distal radius fracture

A N D R E W I R W I N, F R C S E D ( O R T H ) C O N S U L T A N T O R T H O P A E D I C S U R G E O N W E S T H E R T S N H S T R U S T, U K

OBSOLETED. LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation.

2.4 mm Variable Angle LCP Volar Extra-Articular Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology.

Technique Guide. 3.5 mm LCP Low Bend Medial Distal Tibia Plates. Part of the Synthes locking compression plate (LCP) system.

Hand and wrist emergencies

LCP Medial Proximal Tibial Plate 3.5. Part of the Synthes small fragment Locking Compression Plate (LCP) system.

ORTHOLOC 3Di. Foot Reconstruction System Midfoot Fusion Plate SURGICAL TECHNIQUE

The Flower Forefoot PROCEDURE GUIDE.

Dieter Marquardt Medizintechnik GmbH 10 Hand System

Distal Radius Plate Instrument and Implant Set. Discontinued December 2017 DSUS/TRM/0916/1063(1)

MINIMALLY INVASIVE PLATE OSTEOSYNTHESIS FOR DISTAL RADIUS FRACTURES: SURGICAL TECHNIQUE M. TOBE 1, K. MIZUTANI 1, Y. TSUBUKU 1, Y.

OptiLock Periarticular Plating System For Distal Tibial Fractures. Surgical Technique

INnate. Surgical Technique Guide. Anatomic Fixation in Your Hands. The INnate Implant

epak Single-Use Delivery System

ENDOBUTTON Fixation Device

CableFIX Xpress Carpometacarpal Fixation System. Operative technique

2.4 mm Variable Angle LCP Intercarpal Fusion System. Variable angle locking technology for mediocarpal partial arthrodesis.

3. PATIENT POSITIONING & FRACTURE REDUCTION 3 8. DISTAL GUIDED LOCKING FOR PROXIMAL NAIL PROXIMAL LOCKING FOR LONG NAIL 13

Surgical Technique. Lower Extremity Plates and Straight Plates

7/23/2018 DESCRIBING THE FRACTURE. Pattern Open vs closed Location BASIC PRINCIPLES OF FRACTURE MANAGEMENT. Anjan R. Shah MD July 21, 2018.

Locking Radial Head Plates

2.4 mm LCP Volar Column Distal Radius Plates. Part of the 2.4 mm LCP Distal Radius System.

A Patient s Guide to Adult Olecranon (Elbow) Fractures

Flexible Fragment Fixation. Surgical Technique

Mini External Fixator

Surgical Technique International Version

Surgical Technique. Forearm Fracture Solutions

INTERTAN Nails Geared for Stability

LCP Low Bend Medial Distal Tibia Plates 3.5 mm. Anatomic plates with low profile head for intra- and extraarticular fractures.

Case Report Bone Resection for Isolated Ulnar Head Fracture

Technique Guide. 3.5 mm LCP Olecranon Plates. Part of the Synthes locking compression plate (LCP) system.

Arthroscopic Shoulder Repair Using the Smith & Nephew KINSA Suture Anchor

Variable Angle LCP Volar Rim Distal Radius Plate 2.4. For fragment-specific fracture fixation with variable angle locking technology.

System. Humeral Nail. Surgical Technique

Carpal rows injuries!

Case Presentation: Comminuted Fractures of the Proximal Ulna 11/28/2017. Disclosures. Surgical Strategy. Implant Choice. Melvin P.

A Patient s Guide to Adult Radial Head (Elbow) Fractures

ORIGINAL ARTICLE TREATMENT DISTAL RADIUS FRACTURE WITH VOLAR BUTTRESS TECHNIQUE- A CLINICAL STUDY

Surgical Technique Carpal Fusion

Technique Guide. VA-Locking Intercarpal Fusion System. Variable angle locking technology for mediocarpal partial arthrodesis.

Types of Plates 1. New Dynamic Compression Plate: Diaphyseal fracture: Radius, Ulna, Humerus, Rarely tibia

Surgical Technique. Foot and Ankle Technique Guide Ankle Syndesmosis Repair, Operative Technique

Osteotomy System. The reference lines on the plate help facilitate the creation of the osteotomy, when a free hand cut is preferred.

Transcription:

D-RAD SMART PACK Plating System A series of case studies

AO fracture classification: C3 Eben A. Carroll, MD Associate Professor Director Orthopaedic Trauma Service Director Orthopedic Trauma Fellowship Wake Forest University Winston Salem, NC A 45-year-old female with a benign medical history presented to our institution with a chief complaint of left wrist pain. The patient had fallen while competing in a judo tournament landing on her left wrist. Radiographic examination revealed an intra-articular left distal radius fracture. The patient underwent initial closed reduction in the emergency department and was brought to the operating room on hospital day number one. Given her young age and active lifestyle the decision was made to proceed with operative reduction and fixation of her left distal radius fracture. Reconstruction with the D-RAD SMART PACK system allowed neutralization and control of each of the individual fracture fragments in this situation. The trajectory options for the subchondral screws were particularly useful in this case. The low profile design of the plate made us less concerned about late symptomatic hardware. Lastly, the fact that the entire D-RAD single-use kit is disposable meant faster turnover for my operating room.

AO fracture classification: B3 Eben A. Carroll, MD Associate Professor Director Orthopaedic Trauma Service Director Orthopedic Trauma Fellowship Wake Forest University Winston Salem, NC A 28-year-old female was involved in a high-speed motor vehicle collision. She sustained a left scapula fracture in addition to a left intra-articular distal radius fracture. The patient underwent initial closed manipulation and reduction of her left distal radius fracture. Given her young age and active lifestyle, it was decided that she should undergo open reduction and internal fixation. The D-RAD SMART PACK plate s variableangle locking feature allowed for neutralization and control of each individual fragment for this intra-articular distal radius fracture. Additionally, distal screw placement provided adequate subchondral support. The D-RAD plate is a low-profile construct and eliminated concerns about late symptomatic hardware.

AO fracture classification: C2 Louis Catalano III, MD Associate Professor NYU Dept. of Orthopedics New York, NY A 58-year-old male construction worker fell from 10 feet while on the job. As a result, he sustained multiple fractures to his left hand and wrist including an intra-articular distal radius fracture, an ulnar styloid fracture and fractures to the base of the 2nd and 3rd metacarpals. Fractures to the ulna and metacarpals were conservatively managed while it was decided to treat the distal radius fracture surgically with a volar locking plate. The variable-angle locking feature of the D-RAD SMART PACK plate demonstrated its usefulness in this case as three distal screws were angled toward the radial styloid fragment and four were directed at the lunate corner of the radius. The flexibility in distal locking screw trajectory safeguarded against the potential of collapse.

AO fracture classification: C3 Yngvar Krukhaug, MD, PhD Orthopaedic surgeon Senior Consultant Bergen, Norway A 45-year-old male farmer sustained an intra-articular fracture of the right distal radius. This high energy fracture occurred as a result of a fall from height. Prior to our initial interaction, he was unsuccessfully treated at a different hospital via Plaster of Paris (POP). A volar approach was used to access the fracture site. Temporary reduction was achieved through the use of K-wires. A wide volar plate was applied to the reduced distal radius and a variety of non-locking and locking screws were used to adequately maintain anatomical alignment. The D-RAD SMART PACK plate s combination of anatomic design and variable-angle locking holes enabled me to create a scaffold under the subchondral bone while safely positioning the construct beneath the watershed line. Initial AP Initial Lateral Preop Ap (following failed POP treatment) (following failed POP treatment)

AO fracture classification: A3 Yngvar Krukhaug, MD, PhD Orthopaedic Senior Consultant Bergen, Norway A 60-year-old male presented with a severe fracture to the left distal radius a result of a fall from 12 feet. Due to the severity and high degree of instability, open reduction and internal fixation through a volar approach was chosen as the method of treatment. Following the exposure of the fracture site, the distal fragment was reduced and radial length was restored through the use of K-wires. A standard width variable-angle locking plate was applied to maintain length and anatomical alignment. The patient returned after six weeks for follow-up. Fracture healing was well-underway. The low-profile D-RAD SMART PACK plate provided ample stability for this high demand indication while remaining unobtrusive to the surrounding soft tissue.

AO fracture classification: C3 Anjan R. Shah MD Florida Orthopaedic Institute Tampa, Florida Brandon Regional Hospital/Director of Orthopaedic Trauma Brandon, Florida A 35-year-old male unsuccessfully attempted to stop a rolling trailer from striking his SUV. In the process the gentlemen s left wrist sustained an axial loading force as his elbow and wrist were momentarily pinned between the SUV and trailer. The patient was taken to the operating room theater and positioned supine with the left arm on a radiolucent arm table. A volar approach to the wrist was used exposing the underlying distal radius. Due to the severity of injury and degree of shortening an intraoperative external fixator (Smith & Nephew JET-X MINI Bar) was applied to assist with traction. The articular fragments were first reduced and provisionally stabilized with clamps and K-wires. Axial alignment was restored and K-wires were used to maintain temporary fixation. A volar plate was then applied and the fracture was stabilized with multiple non-locking and locking screws as necessary. The external fixation device was disengaged and the wrist and elbow were tested for joint and fracture stability. This case highlights what I believe are the major benefits of the D-RAD SMART PACK system. This injury required subchondral support of the multiple articular fragments. However, there was very minimal subchondral bone available in several of the fragments. With the D-RAD system, I was able to place the plate far distal, allowing for the plate to serve as a buttress. I then used the variable-angle capability of the system to direct and place the screws in the limited subchondral bone. The design of the D-RAD system allowed for a stable anatomic reduction which facilitated early range of motion ultimately improving the prognosis for this high demand patient with an otherwise devastating injury. In addition, the intuitive instrumentation and sterile packaging makes the D-RAD system a good distal radius fracture fixation system that is conveniently available when needed. Preop Oblique

AO fracture classification: C2 Dean G. Sotereanos Clinical Professor of Orthopaedic Surgery Orthopaedic Specialists University of Pittsburgh Medical Center Pittsburgh, PA A 39-year-old female presented with left wrist pain after a fall onto her outstretched hand. X-Rays indicated a displaced intra-articular 4-part left distal radius fracture and a non-displaced left ulnar styloid fracture. The patient underwent open reduction and internal fixation with volar plate of the left 4-part distal radius fracture. The D-RAD plate provided stable fixation of all fragments promoting fracture healing. At six weeks postop the patient was in the process of healing with satisfactory alignment. Posop Lateral This series of studies is provided for information and educational purposes only. These cases may not represent typical surgical outcomes. Every surgery and each patient undergoing surgery represents unique sets of circumstances and, therefore, results may vary. It is not intended to serve as medical advice. It is the responsibility of the treating physician to determine and utilize the appropriate products and techniques according to their own clinical judgment for each of their patients. For detailed product information, including indications for use, contraindications, effects, precautions and warnings, please consult the product s Instructions for Use (IFU) prior to use. Supporting healthcare professionals for over 150 years Smith & Nephew, Inc. 1450 Brooks Road Memphis, TN 38116 USA www.smith-nephew.com Telephone: 1-901-396-2121 Information: 1-800-821-5700 Orders/Inquiries: 1-800-238-7538 Trademark of Smith & Nephew. 2016 Smith & Nephew. 05199 V1 03/16