Ultrasound Measurements and Non-destructive Testing Educational Laboratory

Similar documents
AC : DEVELOPMENT OF NDE LABORATORY FOR AET STUDENTS AND CERTIFICATION PROGRAM

The Physics of Ultrasound. The Physics of Ultrasound. Claus G. Roehrborn. Professor and Chairman. Ultrasound Physics

Nondestructive Evaluation Courses for Undergraduate Engineering and Engineering Technology Students

Linear Ultrasonic Wave Propagation in Biological Tissues

Ultrasonic Testing Level I:

Descriptions of NDT Projects Fall 2004 October 31, 2004

Diploma of Medical Ultrasonography (DMU) Physical Principles of Ultrasound and Instrumentation Syllabus

ULTRASOUND. OB/Gyn (Core) Ultrasound PIEZOELECTRIC EFFECT. Principles of Ultrasound Physics and Instrumentation. Nathan Pinkney, BS, CDOS

Evaluation of the Quality of Thick Fibre Composites Using Immersion and Air- Coupled Ultrasonic Techniques

Ultrasound. Principles of Medical Imaging. Contents. Prof. Dr. Philippe Cattin. MIAC, University of Basel. Oct 17th, 2016

Research on Digital Testing System of Evaluating Characteristics for Ultrasonic Transducer

Ultrasonic Testing. Basic Principles

Development of Ultrasound Based Techniques for Measuring Skeletal Muscle Motion

10 Years Experience in Industrial Phased Array Testing of Rolled Bars

Application of ultrasonic phased array in acoustic logging

Lesson 03: Sound Wave Propagation and Reflection. This lesson contains 15 slides plus 14 multiple-choice questions.

Annular Array Transducer and Matched Amplifier for Therapeutic Ultrasound

ULTRASONIC ARRAY APPROACH FOR THE EVALUATION OF ELECTROFUSION JOINTS OF POLYETHYLENE GAS PIPING

w. D. Jolly, F. A. Bruton, and C. Fedor

PART 1c: Time of Flight Diffraction Ultrasonic Inspector (TOFD) of Welds in Ferritic and Non-Ferritic Materials, Levels 1, 2 and 3

Ultrasonic arrays are now widely used in underwater sonar

COURSE DESCRIPTION FOR NONDESTRUCTIVE TESTING

Ultrasound Physics & Terminology

ULTRASOUND IMAGING EE 472 F2018. Prof. Yasser Mostafa Kadah

Underwater Acoustic Measurements in Megahertz Frequency Range.

Application of Phased Array Radar Theory to Ultrasonic Linear Array Medical Imaging System

Developments in Ultrasonic Inspection II

NMIJ measurement service on ultrasonic field parameters available to demonstrate performance and safety of ultrasonic medical equipment

1. SCOPE ELIGIBILITY EXAMINATION CONTENT RENEWAL & RECERTIFICATION PROCEDURE ESSENTIAL READING...

COWLEY COLLEGE & Area Vocational Technical School

1. Fig. 1 shows data for the intensity of a parallel beam of X-rays after penetration through varying thicknesses of a material

Pipeline Technology Conference 2007

Ultrasonic Testing of Composite Structures

THE DEVELOPMENT AND MANUFACTURE OF FIXED- ULTRASONIC INSPECTION REFERENCE REFLECTORS AND TRANSDUCERS FOR COMPRESSOR BLADE DOVETAILS

Employer s Unit of Competence Ultrasonic testing of materials, products and plant

Performance of phased array and conventional ultrasonic probes on the new ISO reference block

TG-128: Quality Assurance for Prostate Brachytherapy Ultrasound

Reach higher with Inspection Academy GE s Inspection Technologies Global Knowledge Center.

Ultrasound: Past and Present. Lecturer: Dr. John M Hudson, PhD

Non-Destructive Inspection of Composite Wrapped Thick-Wall Cylinders

The Evolution and Benefits of Phased Array Technology for the Every Day Inspector

Detection. at first sight. One of the newest trends

HAND HELD ULTRASONIC SIZING OF STRESS CORROSION CRACKING

Flaw Assessment Using Shear wave Phased array Ultrasonic Transducer

Dr Emma Chung. Safety first - Physical principles for excellent imaging

Ultrasound in Medicine

Ultrasonic Measurement of Aircraft Strut Hydraulic Fluid Level

Development of Indigenous Ultrasonic Data Acquisition and Recording System for ISI of Pressure Tubes of PHWR

Ultrasonic Testing courses at DGZfP Education and Training Ltd

TTU Phased Array: Quality and Productivity

4.17. RESEARCHING MODELS WITH AN ULTRASONIC ECHOSCOPE

Physical Principles of Ultrasound

APPLICATION AND DEPLOYMENT OF ADVANCED NDE TECHNIQUES IN HIGH PRESSURE VESSELS

Development of NDT Based Electronic System for measurement of ultrasonic Parameter of Coal Sample

Research on a Transmit-Receive Method of Ultrasonic Array for Planar Defects

Ultrasonic Thickness Procedure Pulse-Echo Thickness Gage TABLE OF CONTENTS. 1.0 Introduction Reference Documents Summary of Practice 2

Magnetic Analysis Corporation

Ultrasound Principles cycle Frequency Wavelength Period Velocity

Feng Xiujuan National Institute of Metrology (NIM),China

Development of Ultrasound Based Techniques for Measuring Skeletal Muscle Motion

VISUALIZATION OF TRANSDUCER-PRODUCED SOUND FIELDS IN SOLIDS

PART 1b: Automated Ultrasonic Girth Weld Inspection and Phased Array Ultrasonic Testing, Levels 1, 2 and 3

Ultrasound Physics & Doppler

Sound in medicine. CH.12. Dr.Rajaa أ.م.د. رجاء سهيل جنم جامعة تكريت كلية طب االسنان. General Properties of Sound

The table below shows the density and velocity of waves in two different substances. Density / kg m 3 Velocity / m s 1

Multielement ultrasonic probes for projection imaging of biological media

Ultrasound Physics and Knobology Alan Macfarlane. Consultant Anaesthetist Glasgow Royal Infirmary

Basic Physics of Ultrasound and Knobology

Introduction to Biomedical Imaging

MATCHING LAYER DESIGN OF AN ULTRASONIC TRANS- DUCER FOR WIRELESS POWER TRANSFER SYSTEM

Can you believe that the ultrasonic waves are used for cleaning purpose???

OPTION I TEST REVIEW

DIAGNOSTIC TECHNIQUE OF ABNORMALITIES IN BALL BEARINGS WITH AN ULTRASONIC METHOD

ACOUSTORAPHY Acousto-Optical (AO) Ultrasonics & Its Applications

Pulse-Echo Ultrasound Imaging. Resolution in Ultrasound Imaging. Doppler Ultrasound. Resolution vs Penetration. Medical Imaging (EL582/BE620/GA4426)

Uncertainty Evaluation of Effective Radiation Area of Ultrasound Transducers: Preliminary Results of Inmetro s Laboratory of Ultrasound

Diagnostic Ultrasound. Sutiporn Khampunnip, M.D.

DIGITAL IMAGE PROCESSING IN ULTRASOUND IMAGES

HiFFUT A New Class of Transducer

Preamble (disclaimer)

Principles of Ultrasound. Cara C. Prideaux, M.D. University of Utah PM&R Sports Medicine Fellow March 14, 2012

Latest Trends in Circuits, Control and Signal Processing

ADVANCEMENTS IN NON DESTRUCTIVE TESTING

Ultrasonic Testing of Rails Using Phased Array

Lesson 07: Ultrasound Transducers. This lesson contains 73 slides plus 16 multiple-choice questions.

Skin Characterization with High-Frequency Ultrasound

NON-CONTACT ULTRASOUND (NCU)

Intrinsically Safe Ultrasonic Testers: How important are they?

Phased Array Ultrasonics and Eddy Current Examination for Graphite Components

INSPECTION THROUGH AN OVERLAY REPAIR WITH A SMART FLEXIBLE ARRAY PROBE.

Chapter 14. Imaging Artifacts

ANALYSIS OF ULTRASOUND FIELD PARAMETERS DURING SONICATION EXPERIMENTS IN VITRO INFLUENCE OF LABORATORY GLASS AND PLASTICS

COMPARISON OF ATTENUATION AND PHASE VELOCITY MEASUREMENTS IN

INTEGRATED QUALITY ASSURANCE PROGRAM FOR THE HYDRA-70 SOLID. LJ. Bond University of Denver Research Institute [DRl] Denver, CO 80208

4.17. RESEARCHING MODELS WITH AN ULTRASONIC ECHOSCOPE

Introduction. Cardiac Imaging Modalities MRI. Overview. MRI (Continued) MRI (Continued) Arnaud Bistoquet 12/19/03

We are providing Level I, II Training and Certification as per Recommended practice SNT TC 1A 2006 in the following NDT Methods.

Technical Discussion HUSHCORE Acoustical Products & Systems

Terminology Tissue Appearance

Improved Inspection of Composite Wind Turbine Blades with Accessible Advanced Ultrasonic Phased Array Technology

Transcription:

Session 3548 Ultrasound Measurements and Non-destructive Testing Educational Laboratory Vladimir Genis, Horacio Sosa Goodwin College of Professional Studies, Drexel University, Philadelphia, 19104 Emil G. Radulescu School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, Pennsylvania, 19104 Abstract The primary goal of this laboratory is to introduce students to the fundamentals of ultrasound measurements and to demonstrate the basic principles of ultrasound non-destructive testing technique. This laboratory presents the engineering principles of ultrasound measurements to the students by combining hands-on laboratory experience with just-in-time lectures. Specifically, the laboratory work consists of eight 3-hour sessions, where the students learn the engineering and physical principles behind the measurements of sound velocity in water and other materials, attenuation of ultrasound waves at different frequencies, directivity patterns of circular transducers with various resonance frequencies, and dimensions of the inhomogeneities in various materials. The work in the laboratory enhances the fundamentals taught in the classroom sessions. Another goal of this laboratory is to improve the students data gathering and communication skills. Therefore, a concise written report clearly describing all conclusions and comments is required within seven days after completion of the lab, upon which the students become familiar with basic acoustical instrumentation, have hands-on experience with ultrasonic and electronic equipment, and are able to demonstrate the basic principles of ultrasound imaging. In addition, the students are able to determine the frequency of the imaging pulse, pulse duration, pulse repetition frequency, cross section of the ultrasound beam, the axial distance between the transmitter and receiver/reflector, and the thickness of the material. Introduction A new educational laboratory for ultrasound measurements (UM) and nondestructive testing (NDT) has been developed to serve primarily students pursuing a B.S. degree in applied engineering technology. The state of the art facility has also been designed to serve working Page 9.1328.1

individuals interested in improving their skills in UM and/or NDT, as well as those seeking knowledge for professional advancement. The primary goal of this laboratory is to introduce students to the fundamentals of ultrasound measurements and to demonstrate the basic principles of ultrasound nondestructive testing techniques. The laboratory presents the engineering principles of ultrasound measurements by combining hands-on laboratory experience with just-in-time lectures. Specifically, the laboratory work consists of eight 3-hour sessions (within the framework of Drexel s quarter system), where the students learn the engineering and physical principles behind the measurements of sound velocity in water and other materials, attenuation of ultrasound waves at different frequencies, directivity patterns of circular transducers with various resonance frequencies, and dimensions of inhomogeneities in various materials. In addition, students are able to determine the frequency of the imaging pulse, pulse duration, pulse repetition frequency, cross section of the ultrasound beam, the axial distance between the transmitter and receiver/reflector, and the thickness of the material. The work in the laboratory enhances the fundamentals taught in the classroom sessions. An important objective of this laboratory is to improve the students knowledge on data gathering, the identification of sources leading to erroneous measurements, and proficiency in communication skills. To this end, a concise written report clearly describing procedures and results is required within seven days after completion of the lab. Students work individually and in teams on projects drawn from several areas of technological interest. Upon completion of this laboratory/course students become familiar with basic acoustical instrumentation, have hands-on experience with ultrasonic and electronic equipment, and are able to demonstrate the basic principles of ultrasound imaging. The rest of the paper describes the specific laboratories, instrumentation, and procedures associated with the measurements of sound velocity in water and other materials, directivity pattern, and attenuation coefficient in Plexiglas. Measurements of the sound velocity in water Most applications for underwater acoustics, nondestructive testing of materials, and biomedical ultrasound rely on accurate measurements of the sound velocity in water 1 and other materials. The basic principle of sound velocity determination is to measure the time between transmitted and received ultrasound signals (the time-of-flight). In these experiments, the measurement of the transducer displacement is more convenient and accurate than the measurement of the transmitter/receiver or transducer/reflector distance. Such a technique allows one to eliminate additional artifacts caused by the time delays from the transducers and attached electronics. The schematic diagram of the experimental set-up is shown in Fig.1. Page 9.1328.2

Pulser / Receiver Digital Oscilloscope GPIB T/R R Trig Output EXT A B Y X Z X,Y,Z micromanipulator Pulse-Echo Ultrasound Transducer Reflector H 2 O Degased Deionized Water Figure 1. Measurement of the sound velocity in water During this laboratory, the two sets of measurements are carried out: 1. Using one transducer, which is used as transmitter/receiver, and the reflector. 2. Using two transducers, where one of them is used as a transmitter, and the other one is used as a receiver (In this experiment, the reflector is replaced with the second transducer). For the experiments, three sets of transducers with resonance frequencies of 2.25 MHz, 3.5 MHz, and 5 MHz are used. The diameters of all transducers are 12.7 mm. Equipment used: DAEDAL XYZ Scanning System (800 mm x 900 mm x 350 mm Travel). Pulser/Receiver: Panametrics Pulser/Receiver 5073 PR. Oscilloscope: Tektronics TDS220 Digital with the GPIB board. Pentium 4 PC. The placement of the transducers is controlled by the LabView 6 virtual instrument (V I) (Fig.2). The precision of the stepper motors of the Scanning System is 10-4 mm per step, which allows the displacement of the transducers from one position to another very accurately. Initially, transducers are installed at 400-mm distance between each other and are perfectly aligned. Then, one of the transducers or the reflector is moved by 50 mm increments to three different positions. Page 9.1328.3

Figure 2. LabView 6 controller The results obtained for these positions are later averaged. The external triggering of the oscilloscope is activated by the transmitted pulse of the pulser/receiver, which also sends the electrical energy to the piezoelectric transducer. The transducer transmits the ultrasonic wave and receives the echoes. The received ultrasonic signal is then converted to an electrical signal by the pulser/receiver, is amplified, and finally transferred to the oscilloscope. By measuring the time interval between two consecutive pulses on the screen of the oscilloscope and knowing the displacement of one of the transducers, one can estimate the speed of sound in water, as c = x/t, where x is the displacement of the transducer and t is the time interval between two consecutive received pulses. If one of the transducers is replaced with the reflector, then the sound speed can be calculated as c = 2x/t, since the ultrasound wave propagates in both directions - from the transducer, which acts as a transmitter, to the reflector and then back to the transducer, which acts as a receiver. Collected data is then transferred to the computer under control of LabView V I and saved as a text file for future processing using Microsoft Excel. The example of the stored and retrieved data of the received ultrasonic signal is presented in Fig. 3. Page 9.1328.4

Received Ultrasonic Signal using 2.5 MHz Transducers 3.00E+00 2.00E+00 Amplitude (V) 1.00E+00 0.00E+00 1.09E+02 1.09E+02 1.10E+02 1.10E+02 1.11E+02 1.11E+02 1.12E+02 Amplitude (V) -1.00E+00-2.00E+00-3.00E+00 Time (us) Figure 3. Received ultrasonic signal The experiments are repeated with the three sets of transducers using both methods, and the results are presented in the report. Measurements of the sound velocity in other materials The propagation velocity of traveling waves are characteristics of the media in which they travel and are generally not dependent upon the other wave characteristics such as frequency, period, and amplitude. Three pairs of transducers are used in this laboratory session to confirm these statements. The Plexiglas plate and three various rubber plates are used for determining the sound velocity in these materials using the through-transmission configuration. The experimental set-up is shown in Fig. 4. The distance between transducers is larger than the thickness of the sample material, allowing a free alignment and positioning of the sample along the ultrasonic beam. The measurement system consists of a pair of coaxial transducers of similar frequency characteristics, here denoted as a transmitter and a receiver (hydrophone), and a sample material placed between them. The whole system is immersed in a water tank. Two methods for measurements of the sound velocity in the samples are used. Page 9.1328.5

Pulser / Receiver T/R R Trig Output EXT Digital Oscilloscope A B GPIB Y X Z X,Y,Z micromanipulator Transducer d Hydrophone H 2 O De-gased De-ionized Water Figure 4. Measurement of the sound velocity in the material Method # 1. The arrival time of the received signal,, is recorded by the oscilloscope without placing the sample material between the transducers. Then, the sample material is placed between the transducers and the arrival time of the received signal,, is recorded again. The sound velocity in the sample material can now be easily determined via the following expression: d c m, (1) d c where c is the sound velocity in water (m), which was previously determined, d is the thickness of the sample material (m), and (s) Method #2. The arrival time of the received signal,, is recorded by the oscilloscope without placing the sample material between the transducers. Then, the sample material is placed between the transducers and the receiver is moved back from the transmitter by the distance, which is equal to the thickness of the sample material. The arrival time of the received signal,, is recorded again, and the sound velocity is determined by the following expression: Page 9.1328.6

c d m, (2) where It is worth mentioning that Method #2 does not require the knowledge of the sound velocity in water, since the water path for both measurements remains the same and is eliminated in the calculations. The procedures described for both methods are repeated for three types of rubber plates with different thickness. In the final report, students should clearly state the advantages and disadvantages of both methods and compare the results obtained by both methods. The described above technique can be also used for measuring the thickness of the sample materials, as well as the dimensions of inhomogeneities in the sample materials. Directivity Pattern Measurements The directivity pattern is an important far-field characteristic of a transducer. The directivity pattern is a dimensionless and relative parameter. The mathematical expression for the normalized directivity pattern of the plane circular piston is 2 : 2J1( kasin ) p( ), (3) kasin where k = 2f/c is the wave number, J 1 is the first order Bessel function, a is the radius of the transducer, and c is the sound velocity in water. The geometry used in deriving the far-field radiation characteristics of a circular plane piston is presented in Figure 5. x a r r rsin() z rcos() y Figure 5. Far-field pressure distribution of the circular plane piston Page 9.1328.7

In this laboratory session, the directivity pattern is determined analytically and measured experimentally. During the experiment, a projector and a hydrophone are separated by the minimum acceptable distance, x, to minimize interference from reflections. The standard criteria for uniform circular pistons are 2 a x, (4) where c/f is the wavelength, and f is the resonance frequency of the transducer. The experimental set-up for measuring the directivity pattern is similar to that of the one presented in Fig. 4, with the sample material between the transducers removed. Initially, both transducers are aligned in x, y, and directions. The alignment is based on the recording of the maximum amplitude of the received signal. Directivity pattern measurements are carried out with the hydrophone (receiver) fixed and the transmitter rotated using LabView 6 from 0 o to 15 o in 0.1 o increments. For each angle, the peak-to-peak voltage of the received signal is recorded, and the data are saved in the computer as text files. Three pairs of transducers, 12.7 mm in diameter, having resonance frequencies of 2.25 MHz, 3.5 MHz, and 5 MHz are used in these experiments. Results of the computed and experimentally obtained directivity pattern for the 2.25 MHz-resonance frequency transducers is presented in Fig. 6. Directivity Pattern for 2.25 MHz Transducers Normalized Amplitude 1.2 1 0.8 0.6 0.4 expected observed 0.2 0 0 5 10 15 20 Figure 6. Theoretical and experimental directivity patterns of the 2.25 MHz piezoelectric transducer Page 9.1328.8

Measurements of the attenuation coefficient of the ultrasonic waves in Plexiglas The attenuation of a wave is determined by scattering and absorption, which are properties of the medium through which the wave passes. Since the scattering and absorption are frequency dependent, attenuation can be used in the quality control of the materials, as well as in medical diagnostics. In this laboratory session, the immersion technique is used for the measurements of the attenuation coefficient in Plexiglas. Three Plexiglas plates, which have the same mechanical and physical properties and thickness of x 1 = 0.58 cm, x 2 = 1.19 cm, and x 3 = 1.69 cm, respectively, are used in the experiments. The experimental set-up is presented in Figure 4. As can be seen, the Plexiglas pate is placed in the path of a propagating ultrasonic wave, which is partially reflected by changes in the acoustic impedance along its path. At least two samples of the Plexiglas are required for the experiment, since the reflection coefficient of the Plexiglas is not known and should be eliminated from the evaluation of the attenuation coefficient. Both transducers having the same resonance frequency are preliminary aligned in x, y, and directions. The alignment is verified by the maximum peak-to-peak received signal. The following procedure is used for the measurements of the attenuation coefficient: 1. The Plexiglas plate of the thickness x 1 is placed between the transducers (Figure 7). x 1 Transmitter Receiver d Figure 7. Schematic diagram of the attenuation coefficient measurement The peak-to-peak voltage of the received signal is recorded by the oscilloscope and saved in the computer. Page 9.1328.9

2. The Plexiglas plate x 1 is replaced by the Plexiglas plate x 2 (Figure 8). x 2 Transmitter Receiver d + x 2 - x 1 Figure 8. Schematic diagram of the attenuation coefficient measurement To keep a constant length of the water path and eliminate the changes of attenuation in the water, the distance between the transducers is increased by x 2 x 1. This change could be done by moving either transmitter or receiver away from each other. The time waveform of the received signal is then stored in the computer. The attenuation coefficient is computed as follows 3,4 : 20 x log V log V db/cm f 10 pp _ x2 10 pp _ x1 (5) x2 1 The procedure is repeated when the Plexiglas plate, x 2, is replaced by the plate the plate, x 3. Then, the distance between the transducers is increased by x 3 x 1. The time waveform of the received signal is again stored in the computer and the attenuation coefficient is computed as: 20 f log10 Vpp _ x3 log10 Vpp _ x1 db/cm (6) x x 3 1 The average attenuation coefficient is computed at the operating frequency. Measurements are repeated with two other sets of transducers. The attenuation coefficients, in db/cm/mhz, are computed by the following expression [3, 4]: f1 f2 db / cm / MHz (7) f1 f2 The results obtained in this laboratory session are presented in the report and discussed during the final presentation. Page 9.1328.10

Conclusion A unique laboratory experience for students enrolled in Drexel s Applied Engineering Technology program is presented. The article provides a description of a set of experiments in ultrasound and non-destructive testing as well as the protocol of operation. The experiments include measurements of several acoustic parameters, such as sound velocity, attenuation coefficient, and the directivity pattern of the transducers used in the ultrasound measurements and non-destructive testing. The experiments are part of a laboratory course that spans over a period of eight weeks within the framework of a quarter system. Students are organized in groups of two to three, providing a unique opportunity of involvement in each of the experiments and familiarity with equipment and set ups. By the end of the term, students become proficient and knowledgeable in topics that include electronic and ultrasound instrumentation, measurement procedures, data collection, interpretation of results and identification of possible sources of errors. In addition, the course stresses on verbal and written communication skills since each experiment must be presented by each group in the form of a report following best practices utilized in professional settings. This unique laboratory experience, in terms of operation and content, is aligned with the general philosophy and mission of the applied engineering technology program. References 1 N. Bilaniuk and G. Wong. Speed of Sound in Pure Water as a Function of Temperature. J. Acoust. Soc. Am., V. 93, 1609-1612, 1993. 2 L. Kinsler, A. Frey, A. Coppens, and J. Sanders. Fundamentals of Acoustics. John Wiley & Sons. Fourth Edition, 2000. 3 R. Bobber. Underwater Electroacoustic Measurements. Naval Research Laboratory, 1970. 4 V. Genis. Ultrasound Measurements Laboratory. Class-Notes, 2003. Dr. V. GENIS received Ph.D. in Physics and Mathematics from Kiev University, Ukraine. His research interests include ultrasound wave propagation and scattering, ultrasound imaging, electronic instrumentation, piezoelectric transducers. Dr. Genis developed and taught graduate and undergraduate courses in physics, electronics, biomedical engineering, and acoustics. He serves as a member of the Nanotechnology Program Advisory Committee. Dr. H. SOSA has developed and taught over fifteen different undergraduate and graduate courses in various fields of mechanics and physics for engineering students. He serves as a member of the Engineering Science Advisory Committee of the Philadelphia Community College. As a researcher Dr. Sosa has established an international reputation in the field of fracture of piezoelectric materials. He is a member of the Academy of Mechanics. Page 9.1328.11