La Cardio TC nella Malattia Coronarica Risultati del Progetto di Adozione della Regione Emilia-Romagna e Prospettive Future Parma 15 Gennaio 2010

Similar documents
Low Dose Era in Cardiac CT

Cardiac CT - Coronary Calcium Basics Workshop II (Basic)

Disclosure Information

CARDIAC IMAGING FOR SUBCLINICAL CAD

Ultrasound. Computed tomography. Case studies. Utility of IQon Spectral CT in. cardiac imaging

CT Perfusion. U. Joseph Schoepf, MD, FAHA, FSCBT MR, FSCCT Professor of Radiology, Medicine, and Pediatrics Director of Cardiovascular Imaging

Clinical Image Gallery Next Generation Volume 1

CT Imaging of Atherosclerotic Plaque. William Stanford MD Professor-Emeritus Radiology University of Iowa College of Medicine Iowa City, IA

Dual Energy CT of the Heart: Perfusion and Beyond

Is computed tomography angiography really useful in. of coronary artery disease?

Progress in CT. Jim Green Senior Vice President & General Manager Philips CT

A Snapshot on Nuclear Cardiac Imaging

The radiation dose in retrospective

Multisclice CT in combination with functional imaging for CAD. Temporal Resolution. Spatial Resolution. Temporal resolution = ½ of the rotation time

2 Cardiovascular Computed Tomography: Current and Future Scanning System Design

Radiation Dose Reduction Strategies in Coronary CT Angiography

Combined Anatomical and Functional Imaging with Revolution * CT

Dual-Energy CT: The Technological Approaches

Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement

Patient / Organ Dose in CT

Computed Tomography of the Coronary Arteries

Technology Assessment Institute: Summit on CT Dose Cardiac CT - Optimal Use of Evolving Scanner Technologies

WHAT WE CAN LEARN FROM CURRENT CARDIAC CT TECHNOLOGY AND WHAT S NEXT FOR CARDIAC?

Εξελίξεις και νέες προοπτικές στην καρδιαγγειακή απεικόνιση CT. Σταμάτης Κυρζόπουλος Ωνάσειο Καρδιοχειρουργικό Κέντρο

The Emerging Role of Cardiac CT in Cardiovascular Imaging. Anthony Gemignani, MD Vermont Cardiac Network April 28, 2016

Pushing the limits of cardiac CT. Steven Dymarkowski Radiology / Medical Imaging Research Centre

SPECT or PET for Cardiovascular Screening in High-Risk Patients

Radiation Dose Optimization in Cardiac CT: A Technical Review. CHENG Wai Kwong. 17 May Contents

Low-dose CT coronary angiography in the step-andshoot mode: diagnostic performance

Ultralow Dose Chest CT with MBIR

SOMATOM Drive System Owner Manual Dosimetry and imaging performance report

MEDICAL UNIVERSITY of SOUTH CAROLINA

Cardiac CT Angiography

Computed tomography in coronary imaging: current status

Kavitha Yaddanapudi Stony brook University New York

True Dual Energy. Dr. Stefan Ulzheimer, Siemens Healthcare GmbH. DEfinitely Siemens

Doses from Cervical Spine Computed Tomography (CT) examinations in the UK. John Holroyd and Sue Edyvean

COMPUTED TOMOGRAPHY COURSE

Radiation dose reduction in computed tomography: techniques and future perspective

Les Outils Cliniques de Demain en Scanner Cardiaque. Cardiaque Status en ECR 2018 From Diagnosis to Prognosis

Diagnostic and Prognostic Value of Coronary Ca Score

Cardiopulmonary Imaging Original Research

Triple Rule-out using 320-row-detector volume MDCT: A comparison of the wide volume and helical modes

Potential recommendations for CT coronary angiography in athletes

Radiation dose of cardiac CT what is the evidence?

THE TUFFEST STUFF CT REGISTRY REVIEW Live Lecture Seminar SATURDAY CURRICULUM

Coronary Artery Imaging. Suvipaporn Siripornpitak, MD Inter-hospital Conference : Rajavithi Hospital

New Technologies for Cardiac CT. Geoffrey D. Rubin, MD, MBA, FACR, FNASCI Duke University

Comanche County Medical Center to Bring World Class Imaging to the Area

Bringing the power of imaging to your patient. Portable full body 32-slice CT scanner

Managing Radiation Risk in Pediatric CT Imaging

Cardiac CT Techniques in Neonates (and infants)

Outcomes in the NLST. Health system infrastructure needs to implement screening

RAMA-EGAT Risk Score for Predicting Coronary Artery Disease Evaluated by 64- Slice CT Angiography

InTouch Center Local Customer Teams InTouch Agreements Parts Support

X-Ray & CT Physics / Clinical CT

Chapter 4. Department of Cardiology, Leiden University Medical Center, Leiden, The Netherlands. Department of Radiology,

Why is CT Dose of Interest?

Radiation Dose Reduction and Coronary Assessability of Prospective Electrocardiogram-Gated Computed Tomography Coronary Angiography

Diagnostic value of 320-slice coronary CT angiography in coronary artery disease: A

Cardiac Imaging Tests

Cardiac Computed Tomography

128-slice dual-source CT coronary angiography using highpitch scan protocols in 102 patients

The Final 10-Year Follow-up Results from the Bari Randomized Trial J Am Coll Cardiol (2007) 49;1600-6

Multislice CT angiography in cardiac imaging. Part III: radiation risk and dose reduction

The 2016 NASCI Keynote: Trends in Utilization of Cardiac Imaging: The Coronary CTA Conundrum. David C. Levin, M.D.

Introduction. Original Article

CT Myocardial Perfusion: Is there Added Value to Coronary CT?

SPECIFIC PRINCIPLES FOR DOSE REDUCTION IN HEAD CT IMAGING. Rajiv Gupta, MD, PhD Neuroradiology, Massachusetts General Hospital Harvard Medical School

Aquilion ONE: Pediatric Imaging. Richard Mather, PhD. Senior Manager, CT Clinical Science Toshiba America Medical Systems, Inc.

Correlation of Cardiac CTA to Conventional Cardiac Angiography in Diagnosing Coronary Artery Stenosis in a Community Based Center

Dose Reduction Options in Cardiac CT

Simon Nepveu 1, Irina Boldeanu 1, Yves Provost 1, Jean Chalaoui 1, Louis-Mathieu Stevens 2,3, Nicolas Noiseux 2,3, Carl Chartrand-Lefebvre 1,3

Fellows on this rotation are expected to attend nuclear conferences and multimodality imaging conference.

CT Quality Control Manual FAQs

Horizon Scanning Technology Summary. Magnetic resonance angiography (MRA) imaging for the detection of coronary artery disease

Ask EuroSafe Imaging. Tips & Tricks. Paediatric Imaging Working Group. Shielding in pediatric CT

Improving Diagnostic Accuracy of MDCT Coronary Angiography in Patients with Mild Heart Rhythm Irregularities Using ECG Editing

Exploration the Method of Low Dose Coronary Artery Imaging with Dual-Source CT

Toshiba Aquillion 64 CT Scanner. Phantom Center Periphery Center Periphery Center Periphery

Imaging ischemic heart disease: Role of CCTA

Department of Cardiology, Grosshadern Clinic, University of Munich, Marchioninistrasse 15, Munich, Germany. Department of Cardiology,

ROLE OF MULTISLICE COMPUTED TOMOGRAPHY IN CARDIAC IMAGING

Accounting for Imaging Dose

Stress only Perfusion Imaging

Optimal image reconstruction intervals for non-invasive coronary angiography with 64-slice CT

X-ray Computed Tomography (CT)

Analysis of the U.S. Medical Computed Tomography Imaging Systems Market

Alessandro Albonico Philips

Bone Densitometry Radiation dose: what you need to know

Scientific Exhibit. Authors: D. Takenaka, Y. Ohno, Y. Onishi, K. Matsumoto, T.

Current and Future Imaging Trends in Risk Stratification for CAD

Comparison of 64 slice multi detector CT vs 128 slice multi detector CT for acute chest pain evaluation in the chest pain unit

Ct angiography, icd-10

AFib is the most common cardiac arrhythmia and its prevalence and incidence increases with age (Fuster V. et al. Circulation 2006).

Validation of CT Perfusion Imaging Against Invasive Angiography and FFR on a 320-MDCT Scanner

Recent Advancement of Cardiac CT

Image quality and, hence, the diagnostic value of cardiac. Imaging

Acknowledgments. A Specific Diagnostic Task: Lung Nodule Detection. A Specific Diagnostic Task: Chest CT Protocols. Chest CT Protocols

Eur Heart J. 2011;32:637-45

Transcription:

20 minuti

La Cardio TC nella Malattia Coronarica Risultati del Progetto di Adozione della Regione Emilia-Romagna e Prospettive Future Parma 15 Gennaio 2010 Dr. Filippo Cademartiri,, MD, PhD EMC Rotterdam, NL & AO Parma, IT

Cardiac CT is Team-work Best Technology + Best Human Resources

Coronarografia TC Requisiti hardware ELEVATA RISOLUZIONE SPAZIALE Visualizzazione dei piccoli vasi coronarici ELEVATA RISOLUZIONE TEMPORALE Riduzione artefatti da movimento ELEVATA RISOLUZIONE DI CONTRASTO Visualizzazione della parete dei vasi ELEVATA VELOCITA DI SCANSIONE Completare l esame in apnea SINCRONIZZAZIONE CON IL CICLO CARDIACO Fermare il cuore in una fase del ciclo cardiaco

* * MSCT 175 Stress-ECG 33 Germany *p<0.05 Dewey, et al. Eur Heart J 2006

Goldstein JA et al. JACC 2007

Mowatt G et al. HTA 2008

Mowatt G et al. HTA 2008

Coronary CT Dose >20mSv Stress ECG Stress ECO Cardio-RM 0 msv 14-18mSv 18mSv 10-15mSv 15mSv 4-7mSv 8.6mSv 7-9mSv * 2-5mSv/yr 1-3mSv 4.3mSv * 0.1mSv CXR * ECG-Pulsing Natural background CT* CCA 16-CTA 64-CTA Stress Tc99 Stress Tal Picano E, BMJ 2003; Jakobs, Eur. Radiology 2002; ; Hirai, Radiology 2008; Shuman, Radiology 2008 ;Stolzmann, Radiology 2008

Fazel R. NEJM, 2009

Fazel R. NEJM, 2009

>50% Fazel R. NEJM, 2009

X-ray Dose in the real world Chest X-ray Screening chest CT (low dose) Standard chest CT Standard abdomen 3-phase Thoraco-Abdominal CT (staging) Cardiac CT (standard) 0.06mSv 0.3-1mSv 3-8mSv 10-20mSv 25-35mSv 8-20mSv

Mean = 12 (8-18) msv

High definition imaging at up to 230 micron resolution Up to 47% improvement in cardiac resolution Up to 50% dose reduction, with improved image quality Spectral imaging and functional imaging (101 selectable spectral energy images) Gemstone detector to produce sharper and brighter images Up to 500 slices of 4D dynamic coverage Faster scintillator enables higher resolution Produces 2.5 times more views per rotation, improving overall resolution Improved signal with reduced noise from the Volara HD digital DAS Featuring a Performix HD tube which enhances resolution through dynamic control Familiar Xtream interface with more power and capabilities to meet increasingly demanding clinical challenges 2.1mSv

Lifecycle benefits Key performance drivers matched to specific clinical needs now and in the future Compatible with the Extended Brilliance Workspace and Portal Server Advanced applications to fuel tomorrow s research discoveries Essence and Intelligent technologies Proprietary X-ray tube, detector, and reconstruction advancements Revolutionary AirGlide Gantry for whisper-quiet performance NanoPanel 3D spherical detectors with unique ClearRay Collimator for resolution up to 24 lp/cm Scalable imrc X-ray tube and generator system improve image quality in patients with higher BMIs and in cardiac imaging RapidView Reconstruction with quad-core processors and Fast Preview Mode DoseWise Eclipse DoseRight Collimator IntelliBeam Filtration Step & Shoot Cardiac Dedicated Pediatric Protocols 1-2mSv

Toshiba s signature Aquilion Series CT Systems All our Aquilion CT systems feature the benefits of Toshiba s Quantum Advantage, resulting in the industry s best image quality, whatever the choice, from 4 to 64 to 320 slices. * 0.5mm slice * 350 micron isotropic resolution * 2mm low contrast resolution * 32mm volume coverage Using the same detector platform, Aquilion are the only CT systems on the market that offer the choice between high speed image acquisition (up to 16cm width per rotation) and high resolution with either 4, 8, 16 32, 64 or 320 x 0.5mm per rotation. In addition, by a wide variety of dose control tools enable clinicians to minimise radiation exposure to both patients and staff up to 80 percent compared to previous scanners. 3-5mSv

Split-second thorax Scanning the thorax incl. the heart needs 0.6 s, taking the burden of breath-holding off the patient and allowing functional imaging for body regions up to 48 cm. Sub-mSv heart Temporal resolution of 75 ms and scan speed of up to 43 cm/s make heart-scanning without beta-blockers possible and for the first time breath-hold optional with dose levels <1 msv. Single dose Dual Energy With the Selective Photon Shield Dual Energy scans are now dose neutral. Together with dramatically increased energy separation and a wide range of FDA-cleared applications, it s now perfect for routine clinical use. Organ-sensitive dose protection The SOMATOM Definition Flash prevents clinically irrelevant dose for spiral examinations and introduces for the first time organ-sensitive dose protection. 0.9mSv

Cardiac CT New Technologies MORE SLICES + MORE SPATIAL RESOLUTION FASTER ROTATION SPEED HIGHER TEMPORAL RESOLUTION TISSUE SPECTRAL IMAGING LOW DOSE NEW APPLICATIONS (PERFUSION, )

Arthur Robins ACS

CT CAG Stress Tests

Segment 2-3 Non calcific plaque

RI = 1.8

Pundziute G, et al. JACC 2007

Pundziute G, et al. JACC 2007

FRS FRS Hadamitzky M, et al. JACC CVS Img 2009

AOPR, Radiology (in press) Results MACE and Hard Events Stratified for Diabetes and Prior History of CAD % MACE % Hard Events Log-rank p value <o.ooo1 60.3 DM + CAD + DM + CAD - DM - CAD + DM - CAD - 25.7 25 Log-rank p value o.ooo7 19.1 10.3 5.4 3 1.5

AOPR, Radiology (in press) Results Multivariate Independent Predictors of MACE Diabetics HR (95% IC) p value Obstructive CAD 7.61 (2.94-19.6) <0.0001 No. of segments with nonobstructive CAD 1.10 (1.02-1.18) 0.01 Nondiabetics Obstructive CAD HR (95% IC) p value 13.63 (5.8-32.04) <0.0001

Van Werkhoven, et al. Eur Heart J 2009

Van Werkhoven, et al. Eur Heart J 2009

Prospect Retrospect p <0.001 4.2mSv 18.1mSv Prospect Retrospect p <0.001 4.1mSv 20.0mSv Next: sub-msv msv? <1mSv Prospect 1.2-2.6mSv 2.6mSv

Chest + Cardiac 1.6mSv Cardiac 0.8mSv

Thank you Contacts: Filippo CADEMARTIRI,, MD, PhD filippocademartiri@hotmail.com