A SIMPLIFIED INSTRUMENTATION APPROACH TO ULTRASONIC DEBRIDEMENT Hands On Workshop

Similar documents
STRAIGHTFORWARD ULTRASONIC DEBRIDEMENT. Cynthia Fong, RDH, MS

Principles of Periodontal Instrumentation. Periodontology I - 4th year 23/2/2012 Dr. Murad Shaqman

Cause related therapy: Professional mechanical plaque control Zsuzsanna Papp Prof. István Gera

CLINICAL APPLICATION GUIDE DIAGNOSTIC INSTRUMENTS & PERIODONTAL SCALERS/ CURETTES

Dental Hygiene 10/16/2012 8/20/2012 8/29/2013 COURSE OUTLINE DHT 105 Dental Hygiene Clinic I - Preclinic 5 credit hours

The Cavitron family of inserts offers the right tools for any scaling environment.

The Cavitron family of inserts offers the right tools for any scaling environment.

Objectives: What s Your Therapeutic Goal?

Win the Battle Against Biofilm: Leverage the Power of Ultrasonics

Advanced Probing Techniques

Patient had no significant findings in medical history. Her vital signs were 130/99, pulse 93.

Clinical Application Guide SCALERS and CURETTES

PERIODONTAL THERAPY Ultra sonic scaling

M. Molitor REMOVAL OF ORTHODONTIC BANDS AND CEMENT REMOVAL WITH A HAND INSTRUMENT

Surgical Procedure in Guided Tissue Regeneration with the. Inion GTR Biodegradable Membrane System

1B Getting Ready for Instrumentation: Mathematical Principles and Anatomic Descriptors

Scaler Periodontal Curette Explorer Root Planing Check Scaler Sharpening Product Periodontal Probe Resin Color Probe Medicine Applicator

Jordan University of Science and Technology Faculty of Applied Medical Sciences Department of Applied Dental Sciences Second Semester

TASKS. 2. Apply a disclosing agent to make the plaque visible.

Cutting instruments. Instruments

Device Technical File

Maxdent s.r.o.,ondračka Martin,tel:

ORTHODONTIC BANDING AND CEMENTATION. Materials

Cavitron Scaling Innovative solutions for improved comfort and efficiency. Cavitron Select SPS. Cavitron Touch. Cavitron Prophy Jet.

Maintain Your Edge. Instrumental in the preservation of the environment and each other

Full Arch Hygiene Protocol

Elevators. elevators:- There are three major components of the elevator are:-

BOCL-01: Bonding Materials Checklist

High-quality dental instruments for veterinary dentistry

Û MECTRON ULTRASONIC INSERTS

Lec. 3-4 Dr. Saif Alarab Clinical Technique for Class I Amalgam Restorations The outline form

The effect of wear on ultrasonic scaler tip displacement amplitude

1007/10/A/1 DENT-GPLFM-BRO

Hu-Friedy Ultrasonic Inserts

SWISS INSTRUMENTS PM

SWISS INSTRUMENTS PM

LED Light Technology. Scaling. Optimum Power for Treatments. H e a vy Ca l c ul us R emo val

Prosthetic Options in Implant Dentistry. Hakimeh Siadat, DDS, MSc Associate Professor

MemRx Orthodontic Appliances

LESSON ASSIGNMENT. After completing this lesson, you should be able to: 3-1. Identify what oral prophylaxis is.

Give your teeth a hug: a simplified brushing technique for children Journal of Dentistry for Children No.291, September-October, 1984

Efficient Bonding Protocol for the Insignia Custom Bracket System

Amalgam restoration of posterior proximal cavities with deep and concave gingival outlines

Û MECTRON ULTRASONIC INSERTS

AHEAD. Are You. of the Ultrasonic Curve? 110 NOVEMBER 2017 // dentaltown.com. continuing education. AGD Code: 490

CLASS II AMALGAM RESTORATIONS. Amalgam restorations that restore one or both of the proximal surfaces of the tooth

Advancing the Art of Freehand Cosmetic Contouring

EXCEEDS, SATISFACTORY, DOES NOT MEET GRADING CRITERIA FOR PREDOCTORAL PERIODONTICS CASES AND REEVALUATION

Columbia HYGIENE. Barnhart 1-2 The terminal shank is 1mm in diameter and 16mm long with a blade width of 0.8mm.

أ.م. هدى عباس عبد اهلل CROWN AND BRIDGE جامعة تكريت كلية. Lec. (2) طب االسنان

BioFilm Eraser. Advantages

INSTRUCTIONS FOR USE AND CARE

CASE REPORT. CBCT-Assisted Treatment of the Failing Long Span Bridge with Staged and Immediate Load Implant Restoration

THE MULTI-FUNCTION ULTRASONIC TIPS FOR ALL APPLICATIONS TIP BOOK. Expect Perfection. PR-D265E Ver A. Powerful Partners

Root end preparation techniques Summary of papers

Principles of. By: Dr. Ahmad Rabah

Dr.Adel F.Ibraheem Partial Veneer Crown(Three quarter crown) Three quarter (¾ )crown: Uses: Indications ---- For posterior teeth ;

POWER SCALING PIEZON SOLUTIONS

Periodontal Disease. Radiology of Periodontal Disease. Periodontal Disease. The Role of Radiology in Assessment of Periodontal Disease

Delta Force. Bracket System. Putting you in the driver s seat for ultimate control

Everything You Wanted to Know About Extractions but Were Afraid to Ask

KaVo SONICflex Tips KaVo SONICflex tips

Central Incisor DR.Ahmed Al-Jobory B.D.S.,M.Sc. Conservative Department

Surveying. 3rd year / College of Dentistry/University of Baghdad ( ) Page 1

XP Technology. Instrument Guide A Guide for Perio Instruments. American Eagle Instruments presents

Getting the Most Out of Ultrasonic Scaling:

Implantology without Periodontology is like Yin without Yang.

TUBES, LINGUAL ATTACHMENTS AND BANDS. tportho.com cosmeticbraces.com. POD_TPOC_04_Tubes_Linguals_Bands_2017, Rev. 1

KaVo SONICflex tips overview. SONICflex Tip book. Comprehensive user reports on the KaVo tips may be found at

Confidence for you comfort for your patient

Morphology of an Anatomic Crown. By: Assistant Professor Dr. Baydaa Ali Al - Rawi

Fundamental & Preventive Curvatures of Teeth and Tooth Development. Lecture Three Chapter 15 Continued; Chapter 6 (parts) Dr. Margaret L.

FS MTS. Micro Periodontal Tissue Scissors

From Risk to Results: Periodontal Instrumentation for the Advanced Practitioner

SWISS INSTRUMENTS PM

Indications The selection of amalgam as a restorative material for class V cavity should involve the following considerations:

Course Title: DH 118 A Clinical Dental Hygiene I-Lecture Term: Fall

HOW TO USE THIS BOOK. The instruments in this guide are not to scale, and during photography some colours may have been altered.

LMSharpDiamond SHARPEN FREE MICRO COATING CHOOSE SHARP.

Specifications are subject to change without notice. PR-D613E Ver

IMPLEMENTATION GUIDE Module 5 Treatment Planning

Clinpro Glycine Prophy Powder

International Journal of Health Sciences and Research ISSN:

MECTRON ULTRASONIC INSERTS

Archwire Insertion and Disengagement Instruments Technique Guide

Connect your Scanner to SomnoMed Canada. SOMGauge Protrusive Bite Recording - Manual. Scanning Impressions - Lower and Upper

PROPORTION GAUGE T-BAR TIP

The Rondeau System. Brackets, Bands, Buccal Tubes and Archwires. Orthodontic supplies recommended by Dr. Brock Rondeau

Tooth and Surface Identification (TID and SID)

Ultrasonic Instrumentation Instruction in Dental Hygiene Programs in the United States

English. Perfectly in tune. Satelec Surgical Tips

Periodontal disease: Treatment

#whdentalwerk. Now at your dealer or wh.com. video.wh.com. Piezo tip system. Durable. Safe. Effective. By professionals for professionals.

For the Perfect Class V and All Cervical Area Gingival Margins when Placing Direct Composites, Create an Injection Molding Matrix

IFURH0017.V04 NOV2017 INSTRUCTIONS FOR USE CLINICAL PROCEDURE

Archived SECTION 14 - SPECIAL DOCUMENTATION REQUIREMENTS

6610 NE 181st Street, Suite #1, Kenmore, WA

Smile Design. Daniel H Ward DDS 1080 Polaris Pkwy Ste 130 Columbus OH

A New Generation of Micromotor as Well Balanced as an Air Turbine

Essentials of. Dental Assisting. Edition 6. Debbie S. Robinson Doni L. Bird

Transcription:

A SIMPLIFIED INSTRUMENTATION APPROACH TO ULTRASONIC DEBRIDEMENT Hands On Workshop 2014 Kentucky Dental Association Louisville, KY Friday, March 14, 2014 2:00 p.m. 5:00 p.m.

A Simplified Instrumentation Approach to Ultrasonic Debridement Hands On Workshop PRE AND POST TEST 1. Refer to the patient case on the screen. Of the six ultrasonic inserts provided to you, what total number of inserts should be used to provide complete periodontal debridement for this patient? a. 1 to 2 b. 3 to 4 c. 5 to 6 d. more than 6 2. Observe the placement of a curved insert on the screen. Which photograph demonstrates the correct adaptation of the insert for subgingival debridement of the furcation, utilizing a modified instrumentation technique? a. left photograph b. right photograph 3. What is the clinical end point of treatment for periodontal debridement? a. mechanical b. microbial c. surface smoothness d. tissue response 4. Which of the following variables influences the working tip area that is active on an ultrasonic insert? a. water output b. frequency c. power setting d. insert design 5. The power knob on the unit controls which of the following? a. length of stroke b. frequency c. tuning d. water output 1

6. Different power settings should be used with different inserts. Theoretically, the basic principle is the thinner the insert, the lower the power setting. a. both statements are TRUE b. both statement are FALSE c. the first statement is TRUE, the second is FALSE e. the first statement is FALSE, the second is TRUE 7. Which of the following factors should be used to determine the need to replace an ultrasonic insert? a. number of days since the insert was purchased b. amount of wear sustained by the insert c. time interval based on the manufacturers recommendation d. inconsistent water spray patterns 8. Which of the following factors would BEST dictate the ultrasonic insert selected for debridement? a. patient threshold to pain b. quantity of deposit (gross versus fine) c. location of deposit (supragingival versus subgingival) d. clinician s preference 9. What is the rationale for using a RIGHT and LEFT slim type insert? a. periodontitis patients b. furcation involvement c. access depths greater than 4 millimeters d. all of the above 10. When treating a patient during a re-care appointment, which of the following inserts should be used for subgingival deplaquing? a. right angled shank, standard diameter b. contra angled shank, slim diameter c. straight shank, standard diameter d. left angled shank, broad diameter e. both a and c 11. Each of the following instrumentation criterion should be applied during ultrasonic debridement EXCEPT one. Which one is the EXCEPTION? a. use a light exploratory grasp b. adapt the active tip area of the insert c. position the concave surface of the insert against tooth d. avoid placement of the point of the insert on the tooth 2

A SIMPLIFIED INSTRUMENTATION APPROACH TO ULTRASONIC DEBRIDEMENT Hands On Workshop COURSE DESCRIPTION: This hands on workshop will go beyond the fundamentals of ultrasonics to focus on the instrumentation criteria used for gross ultrasonic debridement, definitive debridement, de-plaquing and instrument sequencing. Patient cases will be utilized to simplify proper clinical technique and to assist in selecting the appropriate technology and insert design to meet the individual needs of the patient. At the completion of this workshop, the participant will gain the confidence and skills necessary to immediate3ly incorporate the use of power scalers into your practice. COURSE NOTES: 1. Periodontal debridement: Treatment of gingival and periodontal inflammation through mechanical removal of tooth and root surface irritants to the extent that the adjacent soft tissues maintain or return to a healthy non-inflamed state. Young NS et al. Comprehensive Dental Hygiene Care. 4 th Edition. St. Louis; Mosby 1993; 533-570. 2. End point of periodontal therapy: Tissue response as an end point of therapy should be stressed versus total calculus removal. Drisko and Killoy, Current Opin Dent 1991. 3. Ultrasonic effects: acoustic turbulence intensified acoustic streaming cavitation tip stroke causes coolant to accelerate producing an swirling effect uni-directional fluid flow caused by ultrasound waves the formation of bubbles in liquid by rapid pressure changes; when bubbles implode they produce shock waves in the liquid 3

Acoustic turbulence, acoustic streaming and cavitation have been shown to be effective in removing lipopolysaccharides from root surfaces. The ultrasonic waves have a lethal effect on the gram-negative pathogens. 4. Basic ultrasonic terminology: frequency active tip area stroke the number of times per second the insert tip moves back and forth during one cycle effected by frequency higher frequency = smaller active tip area the maximum distance the insert tip moves during one cycle tuning automatic power adjusted by clinician frequency is automatically tuned to peak performance as the tip is loaded against the tooth/root surface manual power and frequency are adjusted by the clinician through sight and sound clinical power the ability to remove deposits under load factors which determine clinical power: stroke, frequency, type of motion and angulation of the motion against the tooth surface 5. Types of power scalers: Sonic Ultrasonic uses compressed air to move rotor system to produce vibrations water is delivered through hose designed for high and low speed handpiece 3,000 to 8,000 cycles per second elliptical movement at the tip piezoelectric electrical energy is applied to crystals in the handpiece that emits vibration 24,000 45,000 cycles per second linear movement of the tip magnetostrictive electrical energy is applied to coil in handpiece and magnetically changes dimension of metal stack to produce vibrations 18,000 42,000 cycles per second elliptical movement of the tip 4

6. Clinical preparation procedures: Patient a. Comfort tips - use low power setting - use light pressure - position insert parallel to the long axis - do not use the point of the insert - keep the tip active - assess the water control b. Review medical and dental histories - Medical patient considerations predisposition to infection infectious disease transmitted by aerosols respiratory diseases pacemaker children - Dental patient considerations areas of demineralization margins of restorations extreme sensitivity c. Use of protective apparel d. Patient positioning e. Use of anesthetics f. Administer pre-procedural rinse g. Explanation of the procedure Unit Operator a. Position of the unit b. Minimize water contamination c. Insert insertion d. Handpiece line positioning e. Control settings (power, tuning and water adjustments) the patient s oral condition, comfort level, safety, proposed treatment plan and type of insert to be used should ultimately determine the proper control settings in general, use a low power setting for removal of light calculus, stain or for de-plaquing and use a medium to high setting for removal of gross calculus and stain a. Use of protective apparel gloves mask eyewear 5

7. Care and maintenance of ultrasonic inserts: Sterilization do not use cold sterilization or disinfectant solutions use an ultrasonic bath with a non-ionic solution rinse, dry, bag and sterilize do not use an all-plastic bag, use an all paper bag or a combination paper and plastic Maintenance Piezoelectric insert replacement o contingent on the amount of wear sustained by the insert; the use of an efficiency (wear) indicator is recommended Magnetostrictive insert replacement and maintenance o replacement is contingent on factors such as wear, condition of stacks and length of time insert has been in use o most manufacturers recommend replacement on a yearly basis o O-Ring replacement indicated when insert is difficult to seat insert extrudes from the handpiece upon activation leakage occurs replace o-ring with the specific manufacturer s o-ring part o External water tube realignment never manipulate the external water tube itself counter rotate the metal grip and the metal stack until the tube is properly positioned 8. Ultrasonic insert designs: Critically evaluate Lavage (water delivery) Access (size) Adaptation (shape) 9. Insert selection is based on the quantity of the deposit to be removed: - To remove moderate to heavy deposits generally inserts possess an external or internal water delivery system, is large in diameter, universal in design is recommended. - To remove slight to moderate deposits or for de-plaquing inserts possessing an external or internal water delivery system and are slim/thin in diameter with either a straight shank or contra-angled shank is recommended. 6

10. Instrument sequence: - Step 1: Universal ultrasonic insert for gross debridement - Step 2: Thin diameter straight and contra angled ultrasonic inserts for definitive scaling - Step 3: Hand instrumentation for definitive scaling - Step 4: Polishing 11. Clinical ultrasonic technique: - Grasp - Fulcrum/finger rest - Instrumentation techniques Theoretically, if the stroke pattern of the insert is elliptical, then the back, face and lateral borders may be adapted to the tooth/root surfaces since all surfaces are active (360 degrees). If the stroke pattern of the insert is linear, then only the lateral borders may be adapted. To avoid damage to the root or tooth, never adapt the point or tip of the ultrasonic insert toward the tooth/root surface. Magnetostrictive Technology Either a traditional instrumentation technique (which follow the principles of periodontal hand instrumentation) OR a modified instrumentation technique can be used. The following visual cue may assist you in determining if the correct curved slim diameter insert (right or left) is being properly adapted utilizing a modified subgingival technique: place the point or tip of the insert on the occlusal or incisal edge of a tooth observe the convex back curve of the insert use the insert on the tooth surface opposite the direction of the convex curve with the point away from the tooth Piezoelectric Technology Only a traditional instrumentation technique can be used that follow the principles of periodontal hand instrumentation. 7

12. Calculus removal versus plaque removal strokes: a. calculus removal adapt the appropriate insert on the tooth utilize the anterior one third of the insert s working end engage the most coronal portion of the deposit with the insert tip use light intermittent strokes against the deposit continue the stroke in lateral and apical directions until the deposit is completely removed b. inadvertent and definitive deplaquing adapt the appropriate insert on the tooth utilize the anterior one third of the insert s working end begin instrumenting in a systematic order in short, controlled, overlapping, eraser-like strokes to ensure that every square millimeter of the tooth/root surfaces are treated 13. Treatment evaluation: During treatment o concentrate on the process of instrumentation o use tactile and visual cues Post treatment o soft tissue response o levels of periodontal pathogenic organisms ULTRASONIC BIBLIOGRAPHY: Please email a request to cfong4954@aol.com T:R/R/R/L/L-S/L-S/R-S/R M:L/L/L/R/R/R/L/L 8

A SIMPLIFIED INSTRUMENTATION APPROACH TO ULTRASONIC DEBRIDEMENT ULTRASONIC INSTRUMENTATION SELF-DIRECTED CLINICAL EXERCISES INSERT IDENTIFICATION 1. Identify the following inserts according to design: - universal with internal water delivery exiting at base - universal with internal water delivery exiting at anterior third - straight shank, slim diameter with internal water delivery - contra-angled, slim diameter with internal water delivery 2. First, identify the following parts of a magnetostrictive ultrasonic insert: - working tip (face, back, lateral borders, point or tip, shank) - grip - stacks (note date of manufacturing) Next, relate the parts of an ultrasonic insert to the parts of a hand instrument (working end, shank and handle). What similarities or differences can you identify? 3. For each insert, identify and compare the site in which water exits the ultrasonic insert. How does each site influence the control and pattern of the water spray? 4. Compare the differences in diameter between the various types of ultrasonic inserts. 5. Look for variations in the angulation of the ultrasonic insert s shank and relate it to the angulation associated with hand instruments. INSERT INSERTION 6. Simulate bleeding of the handpiece line to reduce any potential contaminants in the tubing. 7. Simulate filling the handpiece with water. 8. Insert and firmly seat the insert. GRASP 9. Use a modified pen or pen grasp with LIGHT pressure to increase optimal efficiency. 10. Drape the handpiece tubing on your forearm or secure it with your pinky finger. CONTROL SETTINGS 11. Adjust the water knob to ensure that sufficient water accesses the tip of the insert. 12. Adjust the power knob to a setting appropriate for the treatment planned. In general, the insert selected and the amount of deposit requiring removal dictates the power setting. Use a low setting for removal of light calculus, stain or for deplaquing and a medium to high setting for removal of gross calculus and stain. 9

INSTRUMENTATION TECHNIQUES Notes: Theoretically, if the stroke pattern of the insert is elliptical (magnetostrictive technology), then the back, face and lateral borders may be adapted to the tooth/root surfaces since all surfaces are active (360 degrees). If the stroke pattern of the insert is linear (piezoelectric technology), then only the lateral borders may be adapted. To avoid damage to the root or tooth, never adapt the point or tip of the ultrasonic insert toward the tooth/root surface. 13. For the following traditional and modified instrumentation adaptation exercises, you will be required to determine which of three inserts (right, left and/or straight) is the correct insert(s) that permits the proper adaptation and access to the surface specified in the tables provided. Using the adaptation criteria provided, adapt the Right, Left and Straight inserts to each tooth and surface. Write in either Right, Left and/or Straight in the column marked Insert(s) to signify your answer to which of the insert(s) can be properly adapted for the individual tooth and technique. Traditional Adaptation This adaptation can be used with both magnetostrictive and piezoelectric technologies; is similar to the criteria used with hand periodontal instruments (i.e. gracey curets); and can access both subgingival and supragingival surfaces: - position the terminal shank of the insert parallel to the long axis of the surface that is to be instrumented - the point of the insert should be the leading portion of the insert during instrumentation - adapt only the active tip area of the insert against the tooth surface - use multi-directional short, intermittent, overlapping strokes TOOTH #/NAME SURFACE INSERT(S) 3 Max Right 1 st Molar Buccal 14 Max Left 1 st Molar Distal (Lingual) 18 Mand Left 2 nd Molar Mesial (Buccal) 30 Mand Right 1 st Molar Buccal 23 Mand Left Lateral Lingual 12 Max Left Bicuspid Distal (Buccal) 27 Mand Right Cuspid Facial 29 Mand Right Bicuspid Mesial (Lingual) 10

Modified Adaptation This adaptation is used only with magnetostrictive technology since the back of the insert is adapted to the tooth surface. When using a curved slim diameter insert (right or left) for this technique, the following visual cues may assist you in confirming the correct curved insert (right or left) is properly adapted: - place the point or tip of the insert on the occlusal or incisal edge of a tooth - observe the convex back curve of the insert - use the insert on the tooth surface opposite the direction of the convex curve with the point away from the tooth When employing this technique, also keep in mind that: - both subgingival and supragingival surfaces can be accessed - only the active tip area of the insert should be adapted against the tooth surface - use multi-directional short, intermittent, overlapping strokes Adapt the Right and Left inserts to each tooth, surface and depth. Write in either Right or Left in the column marked Insert(s) to signify your answer to which of the inserts can be properly adapted utilizing a modified instrumentation technique. TOOTH#/NAME SURFACE DEPTH INSERT 3 Max Right 1 st Molar Buccal 5 mm 14 Max Left 1 st Molar Distal (Lingual) 8 mm 18 Mand Left 2 nd Molar Mesial (Buccal) 6 mm 30 Mand Right 1 st Molar Buccal 7 mm 23 Mand Left Lateral Lingual 6 mm 12 Max Left Bicuspid Distal (Buccal) 8 mm 27 Mand Right Cuspid Facial 7 mm 29 Mand Right Bicuspid Mesial (Lingual) 5 mm 14. When deplaquing with an ultrasonic insert, short controlled, overlapping, eraser like strokes must be used to ensure that every square millimeter of the tooth/root surface is treated. This exercise will assist you in developing a visual appreciation of the number of strokes and time it requires to achieve complete deplaquing. On the tooth schematic provided, use a pen or pencil to color-in the entire root surface from the gingival margin to the epithelial attachment and extending to the proximal surfaces so that no paper color can be seen on the root surface. 11