Phenyl-Hexyl. UHPLC Columns. lternate, complementary selectivity to C18 and C8 bonded phases

Similar documents
Hyper-fast & Super-rugged

The high efficiency of sub-2 µm UHPLC columns combined with the low pressure and high speed of monolith columns.

ACE C18-AR Use the Power!

Protect your expensive HPLC and UHPLC columns from premature failure with MAC-MOD Pre-Column Filters

Aeris. Precision Engineered Core- Shell Particles for Ultra-High Resolution BioSeparations. Aeris PEPTIDE. Aeris WIDEPORE

ACE CN-ES. Extra Stability. Extended Spacer. Enhanced Selectivity ACE. Combining CN polar selectivity with enhanced hydrophobicity

For Far. Greater. UHPLC Column Performance You Must Have Kinetex Core-Shell UHPLC Columns.

Core-Shell / Solid core Particles: A Practical Substitute to Sub-2 Micron Particles: An overview

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development

C30 ISOMERS HAVE MET THEIR MATCH

Roc On with These Dependable LC Columns

Ultimate Core Performance to Maximize Your Investment

Maximizing chromatographic peak capacity with the Agilent 1290 Infinity LC system

Studies on Stationary Phase Selectivity for Solid-Core Particles

Restek Ultra II HPLC Columns

Chromatogram Search Tool Search by compound name, synonym, CAS # or keyword Pinnacle II Columns

Core-Shell Technology for Proteins and Peptides

Thermo Scientific Hypersil BDS Columns

Ultra Columns HPLC COLUMNS

Ultra Columns. also available. ordering note

LC Columns - Exceed the limit. A premium inert range of LC columns delivering optimal peak shape. ProteCol -P PEEK lined

APPLICATIONS TN Overview of Kinetex 2.6 µm Core-Shell Technology

HT5 - High Temperature Stationary Phase for Capillary Gas Chromatography

ACE C18-AR. A C18 bonded phase with unique selectivity. Guaranteed reproducibility. Exceptional bonded phase stability

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS

Am I getting the very best value from my UHPLC analyses?

Agilent Technologies Prep LC Columns

Preparative Chromatography Meets UHPLC

The Raptor HILIC-Si Column

Analytical and Preparative SFC Columns

Maximizing Efficiency Using Agilent InfinityLab Poroshell 120 Columns

Separation of Macrocyclic Lactones (Avermectins) on FLARE C18 MM & FLARE C18+ Columns

Comparison of a UPLC Method across Multiple UHPLC Systems

A New HILIC/RP Mixed-Mode Column and Its Applications in Surfactant Analysis

Sepax Technologies, Inc.

APPLICATIONS Improving Intact Biogeneric Protein Separations with Aeris WIDEPORE Core-Shell Columns

Normal Phase HPLC Column COSMOSIL SL-II

Selectivity Comparison of Agilent Poroshell 120 Phases in the Separation of Butter Antioxidants

Chapter 22: Gas and Liquid Chromatography. Liquid Chromatography: Stationary Phases and Mobile Phases: Normal Phase: Reversed Phase:

Columns for HPLC. Columns for HPLC

The One Minute Chromatographer

HPLC Column for Structural Isomers COSMOSIL Cholester

Yes You Can! New! Amazing EVO C18. Core-Shell Technology

APPLICATIONS TN Dramatically Improve Existing 5 µm and 3 µm Fully Porous Methods with Kinetex 5 µm Core-shell Technology.

Fortis Method Development Options

Columns The FIRST and ONLY sub-2 µm core-shell columns on the market

Barry Boyes 1,2, Shujuan Tao 2, and Ron Orlando 2

Impurity Profiling of Carbamazepine by HPLC/UV

APPLICATIONS TN µm Core-Shell Particle. (continued on page 2) Page 1 of 8. For additional technical notes, visit

The LC Column Playbook

InertSustain Phenylhexyl. A New Second Choice Column to Change Chromatographic Behavior

Exploiting Selectivity in HPLC and UHPLC With Rational Stationary Phase Design

New HPLC Column Options for UHPLC

Extended Temperature Range Impact on HPLC Column Stability and Performance

Eurospher II the logical choice. Physical properties of Eurospher II silica gel: Silica gel: ultra pure, > % Metal content: < 10 ppm

Facile Isolation of Carotenoid Antioxidants from Solanum lycopersicum using Flash Chromatography

ACE ACE. HPLC and UHPLC Columns. Product Catalog

Kromasil The way to peak performance in liquid chromatography

LC Columns with Liquid Separation Cell Technology

ACE ACE. HPLC and UHPLC Columns. Product Catalogue

Reversed-Phase Columns (Other than ODS)

YMC-Triart C18. Multi-layer hybrid material for HPLC ph and temperature stability. Innovative micro-reactor technology

Fused-Core Particles:

Analytical Method Development for USP Related Compounds in Paclitaxel Using an Agilent Poroshell 120 PFP

Biphenyl. Stationary Phase: Fast, Rugged Raptor Columns with Time-Tested Selectivity. Pure Chromatography. Selectivity Accelerated

Separation of Vitamin D and Vitamin D Metabolites on FLARE C18 MM (Mixed Mode) HPLC Column

2012 Waters Corporation 1

NEW. Kinetex. Biphenyl TMS TMS TMS TMS. Selectivity that a C18 just can t give you!

ACE Excel UHPLC Columns

Extended Application Note

Application Note. Separation of clindamycin phosphate and process impurities. Summary. Introduction. Category Pharmaceutical analysis Matrix

LC-MS/MS Method for the Determination of Tenofovir from Plasma

Choosing Preparative Columns

Meteoric Core. Core-Shell Columns for UHPLC & HPLC. Easy Method Optimization! Excellent Chromatography with Fast Separation!

Robust extraction, separation, and quantitation of structural isomer steroids from human plasma by SPE-UHPLC-MS/MS

HIGH PERFORMANCE SEPARATION PHASES

Transfer and Speed-up of Methods to Fused-Core Particle Columns EPA Method 1694

Rapid Gradient and Elevated Temperature UHPLC of Flavonoids in Citrus Fruit

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine

YMC-Triart C18. Multilayer hybrid material for HPLC ph and temperature stability. Innovative micro-reactor technology

Effective use of Pharmacopeia guidelines to reduce cost of chromatographic analysis for Fluticasone propionate

YMC HILIC Columns for Polar Analytes

HICHROM. Chromatography Columns and Supplies NEW PRODUCTS. Catalogue 9. Hichrom Limited

Increasing resolution using longer columns while maintaining analysis time Advantages of the wide power range of the Agilent 1290 Infinity LC System

HPLC Columns. HPLC Accessories HPLC Column Test Mixes Reference Books... HPLC Applications...

GlycanPac AXR-1 Columns

Raptor HILIC-Si: Simplify the Switch to HILIC

IAM Chromatography. Introduction

Product Guide for LudgerSep TM ur2 UHPLC Column for DMB Sialic Acid Analysis

Analysis of Common Sweeteners and Additives in Beverages with the PerkinElmer Flexar FX-15 System Equipped with a PDA Detector

SeQuant ZIC -HILIC For all who expect more...

11:00 a.m. EST Telephone Number: Chair Person: Tim Spaeder

SeQuant ZIC -HILIC For all who expect more...

ACE HILIC + + UHPLC and HPLC Columns. For Reproducible Polar Analyte Separations. Three HILIC Column Chemistries Available

LC/MS Analysis of Various Hydrophilic Compounds Using a Polymer-Based Amino Column - Shodex TM HILICpak TM VG-50 2D

Rapid and sensitive UHPLC screening of additives in carbonated beverages with a robust organic acid column

APPLICATIONS TN A Comparison of Various Kinetex C18 Phases USP: L1

TENOFOVIR TABLETS: Final text for addition to The International Pharmacopoeia (June 2010)

TSKgel Hydrophobic Interaction Chromatography Columns

Transcription:

Phenyl-Hexyl UHPLC Columns lternate, complementary selectivity to A C8 and C8 bonded phases articularly recommended for P compounds containing aromatic groups xcellent bonded phase stability for E durable, long-lived performance plus minimum bleed for LC/MS applications ase deactivated for good peak shape B when separating basic compounds oderate back pressure allows M for UHPLC-like performance with conventional HPLC equipment he use of 2 μm porosity column inlet T frits reduces the inconvenience caused by pressure increases from plugged fits and makes HALO columns more forgiving and easier to use

Phenyl-Hexyl UHPLC Columns HALO Fused-Core particle technology is used to produce UHPLC columns that deliver high speed, high resolution separations with UHPLC equipment, and can even deliver near-uhplc performance with conventional HPLC equipment. HALO columns generate significantly less back pressure compared to other UHPLC columns, putting less stress on the system and facilitating rugged reliable performance. It is this moderate back pressure of HALO columns that permits them to be used with most conventional HPLC equipment. Furthermore, HALO columns utilize a column inlet frit with a porosity that is significantly larger than other UHPLC columns (2 μm versus 0.5 μm). This larger porosity column inlet frit reduces a problem that plagues UHPLC columns, inlet frit plugging. In fact the inlet frit on HALO columns is no smaller than that typically used on columns packed with 5 μm particles. Imagine that. A UHPLC column with the ease of use and reliability of a column packed with 5 μm particles. HALO Fused-Core particles are now available with a phenyl-hexyl bonded phase. The phenyl functionality of this bonded phase provides an additional mechanism of separation that can be particularly useful when separating mixtures that contain compounds with aromatic groups. HALO Phenyl-Hexyl columns are an excellent choice to try when a C8 or C8 phase fails to provide an adequate separation. As with the HALO C8, C8, and RP-Amide phases, ultra-pure reagents, Type B silica, dense bonding technology, and exhaustive endcapping generate a base deactivated stationary phase that provides excellent peak shape for polar compounds. Mechanism of Separation HALO Phenyl-Hexyl can retain analytes via several different mechanisms, including π π interactions between the overlap of the delocalized electrons on the analyte and the stationary phase phenyl group, and via partitioning between the mobile phase and the hydrophobic aryl-alkyl phase. See Figure for the structure of the HALO Phenyl-Hexyl bonded phase. Figure : Structure of bonded phase of HALO Phenyl-Hexyl Silica Stationary Phase Support Si O Si C 6 H 2 Phenyl A phenyl group is bonded to the silica surface via a hexyl chain.

Acetonitrile tends to decrease the π π interactions between aromatic and polarizable analytes and a phenyl stationary phases, but methanol enhances those same interactions, giving both increased retention and changes in selectivity. This does not mean that acetonitrile should not be used with a phenyl bonded phase or that it might not provide an acceptable separation, but methanol is more likely to deliver the additional selectivity that is desired from a phenyl phase. Figures 2 and 3 provide examples of the type of high speed, high resolution separations possible with HALO Phenyl-Hexyl. Figure 2: Fast Separation of Aromatic Compounds Peak Identities:. uracil 2. benzyl alcohol 3. cinnamyl alcohol 4. 4 -bromoacetanilide 5. nitrobenzene 6. butyl paraben 7. chlorobenzene 8. ethylbenzene 9. naphthalene 0. hexanophenone. biphenyl 3 2 4 5 6 7 8 9 Test Conditions: Column: 4.6 x 50 mm HALO Phenyl-Hexyl Mobile Phase: 75/25 MeOH/H 2 O Flowrate:.8 ml/min Temperature: 35 ºC Pressure: 220 bar Detection: UV at 254 nm 0 0 0.2 0.4 0.6 Time (minutes) 0.8.2 Peak Identities: 5. uracil 2. benzamide 3. benzonitrile 4. propyl paraben 5. benzyl benzoate 6. diethylphthalate 7. toluene 8. -chloro-4-nitrobenzene 9. di-n-propyl-phthalate 0. n-propylbenzene 2. n-butylbenzene 2. biphenyl 3. acenaphthene 4. phenanthrene I=unknown impurities 3 4 6 7 8 9 0 Test Conditions: Column: 4.6 x 50 mm HALO Phenyl-Hexyl Mobile Phase: 77/23 MeOH/H 2 O Flowrate:.8 ml/min Pressure: 200 bar Detection: UV at 254 nm Temperature: 40 ºC 2 3 4 I I I 0 0.2 0.4 0.6 0.8.2 Time (minutes) These two chromatograms illustrate how HALO Phenyl-Hexyl columns can provide separation of complex mixtures in a little over a minute. 2

Figure 3: Fast Separation of Anticoagulants Peak Identities:. uracil 2. 4-hydroxycoumarin 3. coumarin 4. 6-chloro- 4-hydroxycoumarin 5. warfarin 6. coumatetralyl 7. alpha-chloroxycoumarin 2 3 Test Conditions: Column: 4.6 x 50 mm HALO Phenyl-Hexyl Mobile Phase: 20% ACN/ 20% MeOH/ 60% 0.% Formic Acid (ph=2.6) Temperature: 45 ºC 6 Flowrate: 2.0 ml/min Pressure: 25 bar Detection: UV at 254 nm 4 5 7 0 0.2 0.4 0.6 0.8.2 Time (minutes) Six anticoagulants are well separated on a HALO Phenyl-Hexyl column in less than 72 seconds. UHPLC Columns High resolution, Hyper-fast, Super-rugged HALO Fused-Core particles are designed for high speed, high resolution liquid chromatography. They are unique particles consisting of a 0.5 μm porous silica halo fused to a.7 μm solid silica core (Figure 4). The high density and extremely narrow size distribution of these Fused-Core particles facilitate the packing of columns with unexpectedly high efficiencies - efficiencies more in line with what you would expect from columns packed with sub-2 μm particles. The reason for this unexpectedly high efficiency is apparently the unusually well-ordered packed bed that minimizes the eddy diffusion contribution to band broadening. HALO columns do, however, generate the back pressure that one would expect from columns packed with 2.7 μm size particles. This pressure is low enough to permit HALO UHPLC columns to be used effectively with conventional HPLC equipment to deliver near-uhplc performance. Figure 4: Fused-Core Particle Technology Porous Layer Solid Core.7 µm 2.7 µm Fused-Core particle technology was developed by Jack Kirkland to produce UHPLC columns that could be effectively used with either UHPLC or conventional HPLC equipment. As the name implies, Fused-Core particles are manufactured by fusing a porous silica layer onto a solid silica particle. Diffusion Path 0.5 µm 3

HALO columns deliver over 90% more separating power (theoretical plates) than a column of the same length packed with 3.5 μm particles and almost three times the plates of a column packed with 5 μm particles (Figure 5). And, because of Fused-Core particle technology, HALO columns maintain their resolving power at high mobile phase velocity. This means that shorter columns and higher flow velocities can be used to achieve remarkably fast high resolution separations. Figure 5: HALO columns deliver more separating power Sub-2 µm HALO 2.2 µm 3 µm 3.5 µm 5 µm 0 50,000 00,000 50,000 200,000 250,000 N/Meter HALO columns deliver over 90% more separating power (theoretical plates) than columns of the same length packed with 3.5 μm particles and almost three times the separating power of columns packed with 5 μm particles. Note: N/Meter values were calculated at the optimum mobile phase linear velocity for each of these stationary phases. The combination of extremely narrow particle size distribution and very dense particles allows for the production of columns that are incredibly rugged and reliable, even when used under UHPLC conditions of high pressure and high flow velocity. In addition, the narrow size distribution of the Fused-Core particles permits the use of 2 μm porosity inlet frits on HALO columns. This is the same inlet frit porosity typically found on columns packed with 5 μm particles. The result is columns capable of delivering the speed and resolution of other UHPLC columns packed with sub-2 μm particles, but with the ease of use and durability of columns packed with 5 μm particles. 4

Specifications: Stationary Phase Support: Ultra-pure, Type B silica.7 micron solid core particle with a 0.5 micron porous silica layer fused to the surface 50 m 2 /gram surface area 90 Å pore size Bonded Phase: Phenyl-Hexyl Densely bonded phase : 3.4 μmoles/m 2 Maximized endcapping Maximum Pressure: 9,000 psi, 600 Bar ph Range: 2 to 9 LC505 Phenyl-Hexyl Ordering Information: Column Dimensions Part Number Price 2. X 30 mm 9282-306 $45.00 2. X 50 mm 9282-406 $525.00 2. X 75 mm 9282-506 $575.00 2. X 00 mm 9282-606 $635.00 2. X 50 mm 9282-706 $735.00 3.0 X 30 mm 9283-306 $45.00 3.0 X 50 mm 9283-406 $525.00 3.0 X 75 mm 9283-506 $575.00 3.0 X 00 mm 9283-606 $635.00 3.0 X 50 mm 9283-706 $735.00 4.6 X 30 mm 9284-306 $45.00 4.6 X 50 mm 9284-406 $525.00 4.6 X 75 mm 9284-506 $575.00 4.6 X 00 mm 9284-606 $635.00 4.6 X 50 mm 9284-706 $735.00 To place an order contact: analytical inc. MAC-MOD Analytical, Inc. 03 Commons Court P.O. Box 587 Chadds Ford, PA 937-9927 Phone: 800-44-7508 Fax: 60-358-5993 Website: www.mac-mod.com Email: info@mac-mod.com HALO and Fused-Core are registered trademarks of Advanced Materials Technology, Inc.