Morita 3D Accuitomo Scanning Protocol

Similar documents
Scanora 3D Scanning Protocol

EWOO Picasso Trio Scanning Protocol

ProMax 3D Scanning Protocol

NewTom 3G & VG Scanning Protocol

CT Scanning Protocol For V2R Guided Surgery Solutions

CAD 3D Printed Implant Surgical Guide Scan to Guide Protocol

CT SCAN PROTOCOL. Shoulder

Instructions for CT Scanning

Connect your Scanner to SomnoMed Canada. SOMGauge Protrusive Bite Recording - Manual. Scanning Impressions - Lower and Upper

TORNIER BLUEPRINT. 3D Planning + PSI SCAN PROTOCOL

fusion treatment is powered by suresmile technology to provide 3D models and fully-customized wires based on your scans of the patient.

How to provide intraoral scans to SomnoMed for the production of SomnoDent device.

Image Diagnostic Technology Ltd IDT Ireland, 15 Market Street, Kinsale, Co. Cork, Ireland P17 XN65 Tel: Mob: IRL:

TORNIER. scan protocol V2.1. Tornier Upper Extremities

Protocol for 3Shape TRIOS

SICAT SURGICAL GUIDES. Instructions for preparation of SICAT CLASSICGUIDE, SICAT OPTIGUIDE and SICAT DIGITALGUIDE

fusion treatment is powered by suresmile technology to provide 3D models and fully-customized wires based on your scan of the patient.

Dental Cone Beam CT. What is Dental Cone Beam CT?

SICAT Surgical Guides. Fabrication of Radiographic Templates Conebeam/CT scanning parameters 3-D Implant planning Ordering Surgical Guides

HOW TO USE PALTOP DIGITAL SERVICE?

KNEE ALIGNMENT SYSTEM (KAS) MRI Protocol

Protocol for itero and ioc

Diagnostics and treatment planning. Dr. Attila Szűcs DDS

Jaw relations and jaw relation records

Extraoral Imaging. Chapter 42. Copyright 2018, Elsevier Inc. All Rights Reserved. 1

3D-MODEL CUSTOM-MADE MODELS SEGMENTATION AND PRODUCTION SERVICE OF BONE MODELS WITH HIGHEST 3D PRINTING RESOLUTION

The Diagnostic Wax Up and Planning Phase of Implant Therapy

TRIOS BY 3SHAPE HOW TO PROVIDE 3SHAPE TRIOS INTRAORAL SCANS FOR THE PRODUCTION OF SOMNODENT DEVICE. KEY QUESTIONS: 1 How do I send my case?

X-Ray & CT Physics / Clinical CT

ident CT Guide Protocol

Articulators. 5- Wax up and refining the occlusion for dental restorations.

Individual Patient Solutions

Dimensional stability in composite cone beam computed tomography

What s New in itero Scanner 4.0

STANDARD OF PRACTICE. Dental CT Scanners CONTENTS. April 2011

UNDERSTANDING DIGITAL DENTISTRY: CBCT AND INTRA-ORAL 30 SCANNING

Xelis Dental - What New in

Easy operation. Numerous diagnostic options. X-rays you can rely on: the ORTHOPHOS XG device family. All ORTHOPHOS XG 3Dready programs at a glance.

Instructions for use for the medical professional English

Cardiac CTA Prospective Gating Broad Beam

Utilizing Digital Treatment Planning and Guided Surgery in Conjunction with Narrow Body Implants. by Timothy F. Kosinski, DDS, MAGD

SICAT FUNCTION TRACK REAL MOTION IN MOTION. Real 3D jaw motion for the first time

Concepts of occlusion Balanced occlusion. Monoplane occlusion. Lingualized occlusion. Figure (10-1)

i-cat CBCT systems CLASSIC (14-BIT) NEXT GENERATION suresmile protocol for i-cat systems DOC

Digital Impression Scanning

Post & Pillar Biopsy Method With a vacuum assisted device

BIOBank Innovation: The Customized Bone Graft

SICAT Surgical Guides. Instructions for preparation of SICAT CLASSICGUIDE and SICAT OPTIGUIDE

ACR MRI Accreditation: Medical Physicist Role in the Application Process

SICAT FUNCTION & OPTIMOTION. Individual functional treatment

Use of the Sicat Surgical Guide In Reconstruction of the Hemi-Mandilectomy Patient

The mission of our company is the development of an individual approach in functional dentistry.

Blue Sky Plan USER MANUAL

Full Mouth Survey. Delta Dental of Massachusetts DeltaDentalMA.com

Locator retained mandibular complete prosthesis (isy Implant System)

GUIDED SURGERY SOFTWARE

The Optimum Choice for Implantologist

CS User and Installation Guide

MS GA 301 MRI Training

Impression Manual.

Perfection is an art, its secret is simplicity. Easy Grip. ModelGuide. Guided surgery. All solutions in one

Guided surgery as a way to simplify surgical implant treatment in complex cases

NEURO PROTOCOLS MRI NEURO PROTOCOLS (SIEMENS SCANNERS)

THE 3D SOLUTION INVENTORS OPTIGUIDE

Mini implants for Stabilization of partial dentures

Cranial idtm. Cranial restoration. id SolutionsTM. Individually designed. Personalized care.

TRI + Digital Solutions DENTAL WINGS MANUAL

Vertical relation: It is the amount of separation between the maxilla and

If you are unable to establish the identification of an

Sample page. Contents

Complete denture impressions

MyCrown. FONA Every dental solution you need. Advanced dental technology. Headquarters BEAUTIFUL CROWNS AND MORE IN JUST ONE VISIT DIGITAL DENTISTRY

SPECIFIC PRINCIPLES FOR DOSE REDUCTION IN HEAD CT IMAGING. Rajiv Gupta, MD, PhD Neuroradiology, Massachusetts General Hospital Harvard Medical School

Conus Concept: A Rewarding Complete Denture Treatment

Interpretation Basics of Cone Beam Computed Tomography COPYRIGHTED MATERIAL

Occlusion & Prosthodontics

The Effect of X Ray Vertical Angulation on Radiographic Assessment of Alveolar Bone Loss

Reinvent Your Practice and Your TEAM through 3D Guided Implantology By Patrick Hayden, M.Ed

Horizontal Jaw Relation

Blue Sky Plan USER MANUAL

Personalized Solutions. MRI Protocol for PSI and Signature Guides

A REMINDER OF THE KEY ESTHETIC GUIDELINES AN INTRODUCTION TO THE DITRAMAX DENTAL DEVICE WHAT BENEFITS DOES DITRAMAX OFFER TO THE DENTIST?

DENTAL ASSISTANT SPECIALTY. Clinical Skills-Radiology

SICAT AIR & OPTISLEEP. The appliance-based 3D solution for the treatment of obstructive sleep apnea

Diagnostic Tools: Equine Dentistry. Dr. Chris Blevins Equine Field Service Clinician

Jaw relation (Maxillomandibular relationship): any one of the infinite

In-Office Cone Beam Computerized Tomography: Technology Review and Clinical Examples Michael Tischler, DDS

VistaVox S 3D from Dürr Dental

Periapical Radiography

Symposium on Occlusal Articulation. Mandibular Movement Recordings and Articulator Adjustments Simplified. Harry C. Lundeen, D.D.S.

Guided immediate loading implant surgery planned with Implant Studio D.D.S. Jae-min, Lee

INTRAORAL SCANNER TRANSFORMING CREATIVITY

For technical assistance: Tel Working time: 8.30 am pm

Low Dose Excellent Image Quality Rapid Reconstruction

Methods of determining vertical dimension of occlusion

Hi RES Extremity - (04/18/2011) CTDI: ~13 mgy per acquisition Used for evaluation of: Ankle Elbow Hand Wrist Foot /Calcaneous Toes Fingers

GUIDED SURGERY TECHNIQUE

UDELL DENTAL LABORATORY Instructions for Use PREAT Precision Attachments

Using cone beam technology in orthodontics

Transcription:

Morita 3D Accuitomo Scanning Protocol Page 1

Scanning Protocol for the Morita 3D Accuitomo General For Use with ident This protocol is written specifically for users of Morita 3D CBCT scanner. Patient Scan with the appliance firmly fixed in the patient s mouth, as instructed by the dentist. Dual Jaw Scans (where necessary): mandible and maxilla must be scanned separately. Radiographic Appliance Scan appliance alone in a Styrofoam (Polystyrene) box. Remove metallic objects such as jewelry and metal prostheses. Page 2

ident Scan Parameters Use the following machine settings: Settings for Patient with Appliance: FOV : 140 x 50 Generator: 90 kvp / 5-6 ma (Lower for small patient, higher for large) Settings for Appliance scan: FOV : 140 x 50 Generator: 60 kvp /1 ma Page 3

Patient Preparation, Positioning and Scanning a) Appliance Positioning: Ensure that the appliance is fixed and stable in the patient s mouth. The technologist should not perform the scan if the appliance does not fit easily and soundly in the patient s jaw contact the dentist. b) Patient Positioning: The patient and the appliance should be motionless during the scanning procedure. In order to ensure this, the patient s head should be firmly attached to the Head Holder. If the lower jaw (mandible) is to be scanned, instruct the patient to bite an object such as a gauze pad. The patient s head should be tilted so as to minimize the interference of the jaw and teeth images with artifacts stemming from metal fillings. A first positioning (before the Pilot scan) should be with the occlusal plane parallel to the scanner light marker. If the pilot scan reveals that the angulation is wrong, then further head tilting should be carried out. Each time that the patient s head is re-positioned, attachment to the head holder should be checked. Any metal object such as jewelry should be removed from the scanned region. c) Patient Scanning: The region to be scanned should include all the relevant jaw volume, the appliance and the teeth. The horizontal marker line should be in center of the region of interest, in order not to miss relevant volume due to accidental patient motion. Prior to the scan, the patient should be instructed not to swallow. The CT Technologist may wish to instruct the patient to swallow several times before starting the CT scan. Page 4

The Appliance Positioning and Scanning a) Positioning: The appliance should be placed in a Styrofoam (Polystyrene) box, in the same orientation as scanned in the patient s mouth. The appliance should be positioned similarly to the patient s head position during the patient scan, including the distance to the center of the FOV, the angle and the orientation (see figure below). b) Appliance Stability: Ensure the stability of the appliance. Never place the appliance in a vertical position. Ensure only the appliance is being scanned (without any external interference). c) Styrofoam box: for further information, contact your local ident support. Page 5

Data Reconstruction and Saving Use i-dixel CT acquisition software: Click on Recon icon Select 0.250 pixel size and 0.250 slice thickness (or the closest size that the software lets you pick) Select Z slices Save as DICOM Page 6

Page 7

Data Saving a) Data for each jaw should be saved in separate datasets (see below). The data for each template should correspond to the data of the patient. b) Each patient and template datasets should be copied to separate folder, compressed (right click on folder > send to compressed zipped folder). c) Send zipped file(s) to ident partner via the internet (contact your ident partner for upload information). Maxilla Patient scan data Appliance scan data Mandible Patient scan data Appliance scan data Page 8