Universal Couchtop. for safe, efficient treatment planning + imaging. 5 Year Warranty. Long Extension. 1 Piece

Similar documents
Universal Couchtop. for safe, efficient treatment planning + imaging. Long Extension. 1 Piece

Protura Robotic Patient Positioning System. for efficiency + performance

SBRT Patient Positioning + Immobilization Solutions. for improved patient outcomes + clinical efficiencies

SBRT Patient Positioning + Immobilization Solutions. for improved patient outcomes + clinical efficiencies

Breast + Thorax Positioning. for accuracy, reproducibility + patient comfort

Solutions Guide Volume 2.0 Comprehensive Motion Management Solutions

Solutions Guide. Volume 3.0

FROM ICARO1 TO ICARO2: THE MEDICAL PHYSICS PERSPECTIVE. Geoffrey S. Ibbott, Ph.D. June 20, 2017

Linac or Non-Linac Demystifying And Decoding The Physics Of SBRT/SABR

I. Equipments for external beam radiotherapy

EXACTRAC HIGHLY ACCURATE PATIENT MONITORING

Unrivaled, End-to-End

Varian Edge Experience. Jinkoo Kim, Ph.D Henry Ford Health System

7/10/2015. Acknowledgments. Institution-specific TG-142? AAPM:Task Group-142. Failure-Mode & Effects Analysis

Work partially supported by VisionRT

PINPOINTING RADIATION THERAPY WITH THE PRECISION OF MR.

Implementation of advanced RT Techniques

Varian Treatment. Streamlined Treatment Delivery Management Application. Specifications

JP MORGAN HEALTHCARE CONFERENCE DOW R. WILSON President and Chief Executive Officer 1 FOR INVESTOR USE ONLY

Ingenia MR-RT. MR Systems. The comprehensive MR-sim solution to fit your planning

SBRT fundamentals. Outline 8/2/2012. Stereotactic Body Radiation Therapy Quality Assurance Educational Session

Herlev radiation oncology team explains what MRI can bring

ph fax

Product Catalog. Patient Positioning. Patent(s) Pending

8/2/2018. Disclosure. Online MR-IG-ART Dosimetry and Dose Accumulation

Image Guided in Radiation Therapy (IGRT) Chumpot Kakanaporn Med Phys Radiation Oncology Siriraj Hospital

MAX-HD SRS PHANTOM THE COMPREHENSIVE END-TO-END SRS PHANTOM SCAN PLAN LOCALIZE TREAT. distributed by:

Radiosurgery. Most Important! 8/2/2012. Stereotactic Radiosurgery: State of the Art Technology and Implementation Linear Accelerator Radiosurgery

Elekta Synergy Digital accelerator for advanced IGRT

Imaging of Scattered Radiation for Real Time Tracking of Tumor Motion During Lung SBRT

Quality assurance in external radiotherapy

Nuclear Associates

A method to predict patient specific table coordinates for quality assurance in external beam radiation therapy

Technique For Plan Quality and Efficiency Using VMAT Radiosurgery For Patients with Multiple Brain Metastases

Credentialing for the Use of IGRT in Clinical Trials

Varian Acuity BrachyTherapy Suite One Room Integrated Image-Guided Brachytherapy

Motion gating and tracking techniques: overview and recent developments

Integrating the Radixact into a Highly Comprehensive Center

THE AIO SOLUTION ALL-IN-ONE PATIENT POSITIONING SYSTEM

Radiation Oncology Accessory Catalog. vision possible. Enhancing clinical workflow

Stereotaxy. Outlines. Establishing SBRT Program: Physics & Dosimetry. SBRT - Simulation. Body Localizer. Sim. Sim. Sim. Stereotaxy?

In-Room Radiographic Imaging for Localization

1 : : Medical Physics, Città della Salute e della Scienza, Torino, Italy

8/3/2016. The EPID Strikes Back! - EPID In-Vivo Dosimetry. EPID Research Number of Publications. Why EPID in-vivo? Detectable errors: patient

In-Room Radiographic Imaging for Localization

8/2/2017. Objectives. Disclosures. Clinical Implementation of an MR-Guided Treatment Unit

Clinical Precision for Best Cancer Care. Dee Mathieson Senior Vice President Oncology Business Line Management

Risk-based QM for Incorrect Isocenter at Day 1 Setup. TG 100 risk based QM development Process Mapping

Flattening Filter Free beam

Can the compact economical Nano-X linear accelerator system be a solution for improving access to radiotherapy globally?

Image Registration for Radiation Therapy Applications: Part 2: In-room Volumetric Imaging

Elekta Infinity. Digital accelerator for advanced treatments. Redefining treatment precision, speed and control

SAGITTILT PRONE BREAST SOLUTION

Objective. Evaluation of Linear Accelerator Performance Standards using an Outcome Oriented Approach. Linac performance standards*

Normal tissue doses from MV image-guided radiation therapy (IGRT) using orthogonal MV and MV-CBCT

IMRT/IGRT Patient Treatment: A Community Hospital Experience. Charles M. Able, Assistant Professor

Case Study. Institution Farrer Park Hospital

IGRT1 technologies. Paweł Kukołowicz Warsaw, Poland

Global Radiation Therapy Market Report

Spatially Fractionated Radiation Therapy: GRID Sponsored by.decimal Friday, August 22, Pamela Myers, Ph.D.

Importance of daily portal imaging for Head and Neck IMRT treatments. Luciant Wolfsberger Brigham & Women s Hospital

STEREOTACTIC DOSE VERIFICATION PHANTOM VERSATILE STEREOTACTIC QA PHANTOMS

Implementing New Technologies for Stereotactic Radiosurgery and Stereotactic Body Radiation Therapy

A new geometric and mechanical verification device for medical LINACs

SHIELDING TECHNIQUES FOR CURRENT RADIATION THERAPY MODALITIES

CHAPTER 5. STUDY OF ANGULAR RESPONSE OF asi 1000 EPID AND IMATRIXX 2-D ARRAY SYSTEM FOR IMRT PATIENT SPECIFIC QA

Intensity modulated radiotherapy (IMRT) for treatment of post-operative high grade glioma in the right parietal region of brain

7/31/2012. Volumetric modulated arc therapy. UAB Department of Radiation Oncology. Richard Popple, Ph.D.

Intensity-Modulated and Image- Guided Radiation Treatment. Outline. Conformal Radiation Treatment

CURRICULUM OUTLINE FOR TRANSITIONING FROM 2-D RT TO 3-D CRT AND IMRT

Reena Phurailatpam. Intensity Modulated Radiation Therapy of Medulloblastoma using Helical TomoTherapy: Initial Experience from planning to delivery

Annual Shareholders Meeting

place needle guide insert

What is the CyberKnife System?

Imaging Rotation. University of Michigan Department of Radiation Oncology Division of Radiation Physics. Resident:

Hybrid VMAT/IMRT Approach to Traditional Cranio-Spinal Irradiation (CSI): A Case Study on Planning Techniques and Delivery

Learning objective. Outline. Acknowledgements. KV CBCT Imaging Part I. R Hammoud AAPM 2008 CE-Therapy (SAM) 1

Dental ConeBeam Computed Tomography (CBCT) X-ray Systems

Intensity Modulated Radiation Therapy: Dosimetric Aspects & Commissioning Strategies

Quality Assurance of Ultrasound Imaging in Radiation Therapy. Zuofeng Li, D.Sc. Murty S. Goddu, Ph.D. Washington University St.

SunCHECK Patient Comprehensive Patient QA

QA - Prone Breast Board and Its Dosimetric Effect. Inter-fractional Prone Breast Setup Variation

IMRT for Prostate Cancer

SUPERIORITY OF A REAL TIME PLANNING TECHNIQUE OVER IMAGE GUIDED RADIATION THERAPY FOR THE TREATMENT OF PRIMARY PROSTATE CANCERS

Introduction. Modalities used in imaging guidance. Flat panel detector. X-ray Imaging Dose to Patients in the Era of Image-Guided Radiation Therapy

Endorectal Balloon (ERB) Endorectal Balloon (ERB) Instructions for Use

Cancer Care A Technology Overview

VARIAN ONCOLOGY. RapidArc. One revolution is all it takes.

Credentialing for Clinical Trials -IGRT. Evidence Based Radiation Oncology. Levels of Clinical Evidence. Why Credentialing?

Clinical Impact of Couch Top and Rails on IMRT and Arc Therapy

SUMITOMO Particle Therapy Technologies

QUALITY ASSURANCE IN RADIOTHERAPY THERAPY EQUIPMENT

Leksell Gamma Knife Icon contributes to significant growth, greater efficiency and an enhanced patient experience

Evaluation of Monaco treatment planning system for hypofractionated stereotactic volumetric arc radiotherapy of multiple brain metastases

UNIVERSITY OF WISCONSIN-LA CROSSE Graduate Studies

SRS Uncertainty: Linac and CyberKnife Uncertainties

Special Procedures Rotation I/II SBRT, SRS, TBI, and TSET

Which Planning CT Should be Used for Lung SBRT? Ping Xia, Ph.D. Head of Medical Physics in Radiation Oncology Cleveland Clinic

A TREATMENT PLANNING STUDY COMPARING VMAT WITH 3D CONFORMAL RADIOTHERAPY FOR PROSTATE CANCER USING PINNACLE PLANNING SYSTEM *

NJ CBCT Regulation FAQ & Assistance

Transcription:

Universal Couchtop for safe, efficient treatment planning + imaging Long Extension 1 Piece 5 Year Warranty

Junction, Rail and Artifact-free The Universal Couchtop is a modern and comprehensive solution for enabling advanced treatments in your clinic. Specifically designed to answer the demands of IGRT delivery, the Universal Couchtop Long Extension contains no rails or junctions in the treatment area to help facilitate better dose delivery and target coverage. Long Extension 5 Year Warranty on Universal Couchtop Large, junction-free and artifact-free treatment area with low attenuation and no overlay required Utilizes 7 cm indexing CIVCO 7 cm Self-locking extension seam located outside of treatment field The implementation of UCT has allowed us to introduce kv and CBCT imaging on our treatment units. It is the preferred treatment unit for all complex patients including head and neck and lung treatments. - Aniko Cooper, Director of Radiation Therapy Services, North Queensland Oncology Service, Douglas, Australia Convenient wall storage device holds up to four extensions

Extensions to Treat Many Disease Sites Universal Couchtop allows full flexibility with many extension options to help facilitate patient imaging, simulation and treatment throughout the day. These extensions feature a unique profile allowing for direct attachment of all CIVCO Body Pro-Lok SBRT bridges, trupoint ARCH SRS/SRT System and head & neck thermoplastics. Rectangular Extension Available standard or with an optional embedded wire to ensure patient alignment Type-S Extension Compatible with Type-S Thermoplastics, including the ClearVision open face mask designed for use with vision/camera systems All Long Extensions (SBRT Immobilization) Posifix Extension Compatible with Posifix Thermoplastics and trupoint ARCH SRS/SRT System Kevlar Extension Compatible with Varian s Calypso System Grid Extension Helps minimize surface dose and skin reactions Posifix Extension (SRS/SRT Immobilization) UCT Head Extension Extends the patient an additional 17 cm End Plates for Varian Allows the use of various QA devices Please contact your sales representative to learn more about CIVCO s Long Extension options available specifically for your facility s Linac or CT models. Type-S & Posifix (Head & Neck Positioning) *Specific Universal Couchtop Long Extensions have been validated on TrueBeam and VitalBeam. CIVCO positioning and immobilization devices have not been validated with TrueBeam or VitalBeam and Varian is not liable for use of these products. Universal Couchtop has not been validated on HyperArc or Edge.

Dosimetrically Matched Universal Couchtops Universal Couchtop is available in dosimetrically matched couchtops for most major CT and Linac models to provide seamless transition from simulation to treatment. DoseMatch Technology Reduce set-up and treatment errors Installing Universal Couchtop on all department pedestals will offer the same: Dose attenuation Deflection Indexing Immobilization device attachment Scan or treat patients on any CT or Linac Installing matching couchtops allows patients to be scanned or treated on any CT or Linac as required. This is ideal when machines are down or departments are trying to manage patient throughput. VARIAN ELEKTA GE PHILIPS SIEMENS TOSHIBA CIVCO s dosimetrically matched Universal Couchtops give us more confidence in dose calculations when planning patients who will be treated on the linac. Not having to use overlays has definitely provided us additional conveniences. - Brian Smaga, Radiation Therapist, Agnesian Healthcare, Fond Du Lac, Wisconsin One can minimize or even eliminate the effort needed to model the couch by installing matching couch tops in the CT simulator and linear accelerator. - AAPM Task Group 176 Universal Couchtop 1 Piece The Universal Couchtop 1 Piece is an ideal IGRT and SBRT solution with a uniform design and no junctions. This couchtop offers a dosimetrically matched couchtop for most major CT and Linac models. No extension or seams Low attenuation and surface dose Economic option for facilities with multiple linear accelerators and CTs Allows for attachment of Body Pro-Lok SBRT bridges and accessories for SBRT Immobilization Utilizes Prodigy 2 indexing at 7 cm increments 1 Piece

UCT LE Statistics UCT 1 Piece Statistics Load Rating Entire System: 220 kg/484 lbs Extension Only: 178 kg/392 lbs Load Rating Entire System: 200 kg/444 lbs Attenuation Gantry () (5 x 5) 180 0.971 0.969 200 / 160 0.968 n/a 210 0.967 n/a 220 / 140 0.962 n/a Attenuation Gantry () (5 x 5) 180 0.971 0.969 200 / 160 0.968 n/a 210 0.967 n/a 220 / 140 0.962 n/a Surface Dose 18MV 18 MV Open Field 19.1% 30.5% 16.1% 20.6% UCT LE 94.1% 97.2% 69.9% 79.4% Posi Extension 82.6% 89.7% 56.9% 69.4% Posi Extension 89.6% 93.2% 64.6% 73.6% Surface Dose 18MV 18 MV Open Field 19.1% 30.5% 16.1% 29.6% UCT 1 Piece 94.1% 97.2% 69.9% 79.4% Deflection The Universal Couchtop Long Extension contributes less than 1 mm of deflection to the system following IEC 60976 (2007) Section 15.2.2 The Universal Couchtop 1 Piece meets the deflection standards and requirements of IEC 60976 (2007) Section 15.2.2 on the Varian Exact couch Attenuation and surface dose values are approximate due to variation in machine characteristics.

Global Sales Office 1401 8 th Street SE Orange City, IA 51041 800.842.8688 +1 712.737.8688 info@civcort.com www.civcort.com COPYRIGHT 2017. CIVCO AND POSIFIX ARE REGISTERED TRADEMARK OF CIVCO MEDICAL SOLUTIONS. BODY PRO-LOK, BODY PRO-LOK ONE, CLEARVISION, DOSEMATCH TECHNOLOGY, PRODIGY, TRUPOINT ARCH, TYPE-S AND UNIVERSAL COUCHTOP ARE TRADEMARKS OF CIVCO. ALL OTHER TRADEMARKS ARE PROPERTY OF THEIR RESPECTIVE OWNERS. ALL PRODUCTS MAY NOT BE LICENSED IN ACCORDANCE WITH CANADIAN LAW. 2016P1108 REV. B