The evolution. AORFIX AAA Stent Graft now with the new AORFLEX Delivery System

Similar documents
Right Choice for Right Angles

Challenging anatomies demand versatility.

Zenith Renu AAA Converter Graft. Device Description Planning and Sizing Deployment Sequence Patient Follow-Up

LOWERING THE PROFILE RAISING THE BAR

Talent Abdominal Stent Graft

Access More Patients. Customize Each Seal.

My personal experience with INCRAFT in standard and challenging cases

Bifurcated system Proximal suprarenal stent Modular (aortic main body and two iliac legs) Full thickness woven polyester graft material Fully

Durability of The Endurant Stent-Graft through 5 Years

Zenith Alpha T HORACIC ENDOVASCULAR GRAFT

History of the Powerlink System Design and Clinical Results. Edward B. Diethrich Arizona Heart Hospital Phoenix, AZ

Durable outcomes. Proven performance.

Anatomical challenges in EVAR

Aortic stents, types, selection, tricks in deployment.

Challenges in the treatment of infrarenal aneurysm & considerations for a durable repair

FROM THE EVERYDAY TO THE EXTRAORDINARY

A New EVAR Device for Infrarenal AAAs

From 1996 to 1999, a total of 1,193 patients with

Endovascular treatment of morphologically challenging abdominal aortic aneurysms using flexible endograft

Overcoming Challenging Aortic Anatomy: from Hostile Necks to Tortuous Iliac arteries

Robert F. Cuff, MD FACS SHMG Vascular Surgery

Optimizing Accuracy of Aortic Stent Grafts in Short Necks

Hostile Proximal Neck: A New Conformable EVAR Device

Young-Guk Ko, M.D. Severance Cardiovascular Hospital, Yonsei University Health System,

ENCORE, a Study to Investigate the Durability of Polymer EVAR with Ovation A Contemporary Review of 1296 Patients

THE THE MORE MORE NATURAL APPROACH TO OPTIMAL FIT

Considerations for a Durable Repair

Cook Medical. Zenith Flex AAA Endovascular Graft with Z-Trak Introduction System Physician Training

INCRAFT system: Update from the Pivotal INSPIRATION Study

Quick Reference Guide

Ovation. Sean Lyden, MD Department Chair, Vascular Surgery Cleveland Clinic

Ancillary Components with Z-Trak Introduction System

14F OD Ovation Abdominal Stent Graft System

TriVascular Ovation Prime Abdominal Stent Graft System

Aorfix Pythagoras US Clinical Trial:

ABDOMINAL XT ABDOMINAL STENT GRAFT SYSTEM

THE ENDURANT STENT GRAFT IN HOSTILE ANEURYSM NECK ANATOMY

Anatomy-Driven Endograft Selection for Abdominal Aortic Aneurysm Repair S. Jay Mathews, MD, MS, FACC

GORE EXCLUDER AAA Endoprosthesis demonstrates long-term durability. Michel Reijnen Rijnstate Hospital Arnhem, The Netherlands

No Neck Is Needed! Treat the Aneurysm Instead! Andrew Holden, MD Associate Professor of Radiology Auckland City Hospital

Citation for published version (APA): Tielliu, I. F. J. (2010). Endovascular repair of peripheral artery aneurysms Groningen: s.n.

Lessons learned from Ch-EVAR for the treatment of. Miltos Matsagkas MD, PhD, FEBVS Professor of Vascular Surgery University of Thessaly

Feasibility of aortic neck anatomy for endovascular aneurysm repair in Korean patients with abdominal aortic aneurysm

What's on the Horizon for AAA: Unilateral & Percutaneous, "UP-EVAR" System Zoran Rancic M.D., Ph.D.

Challenges with Complex Anatomies Advancing Care in Endovascular Aortic Treatment

How to select FEVAR versus EVAR + endoanchors in short-necked AAAs

Current Status of Abdominal Aortic Stent Grafts. John R. Laird Professor of Medicine Director of the Vascular Center UC Davis Medical Center

When to use standard EVAR with EndoAnchors or CHEVAR in short-neck AAAs LINC ASIA 18

All-In-One. Iliac Branch System. PER F ORM ANC E b y d e s i g n ILIAC BRANCH ENDOPROSTHESIS

Treatment options of late failures of EVAS. Michel Reijnen Rijnstate Arnhem The Netherlands

Endovascular Repair o Abdominal. Aortic Aneurysms. Cesar E. Mendoza, M.D. Jackson Memorial Hospital Miami, Florida

Chimney endovascular aneurysm sealing (ch-evas) for ruptured abdominal aortic aneurysms (AAA) due to type Ia endoleak following failed EVAS

The Ventana Off-the-Shelf Graft for Pararenal AAA. Andrew Holden Associate Professor of Radiology Auckland Hospital

Abdominal Aortic Aneurysm 가천대길병원 이상준

GORE EXCLUDER AAA Endoprosthesis ANNUAL CLINICAL UPDATE OCTOBER Section I Clinical experience. Section II Worldwide commercial experience

Increased Flexibility of AneuRx Stent-Graft Reduces Need for Secondary Intervention Following Endovascular Aneurysm Repair

EVAS using Nellix in my practice Where are we today?

EVAR replaced standard repair in most cases. Why?

Technology. The introduction of endovascular aortic repair. cover story

Current Status of EVAR for Infrarenal AAA. 31 st Annual Florida Vascular Society. PENN Surgery

Degeneration of the Neck Post Implementation - a New Era of AAA Stent

The clinical update for the Zenith AAA Endovascular Graft has included results from the Zenith AAA Endovascular Graft multi-center clinical study,

Conflicts of Interest. When and Why Complex EVAR in Tx of juxta/suprarenal AAA? Summary. Infrarenal EVAR for short necks 2y postop

thoracic stent graft system Smallest delivery profile as from 20 F

Corporate Update Simon Hubbert, CEO Bill Kullback, CFO June, 2015

Optimized for Performance and Ease of Use. Designed with Titanium Oxide Surface. References

Percutaneous Approaches to Aortic Disease in 2018

How to Categorize the Infrarenal Neck Properly? I Van Herzeele Dept. Thoracic and Vascular Surgery, Ghent University, Belgium

Standardization of the CHEVAR procedure: How a standard approach has improved outcomes. Prof Peter Holt St George s, London

Important Update to Field Safety Notice Nellix EndoVascular Aneurysm Sealing System Updated Instructions for Use (IFU)

Taming The Aorta. David Minion, MD Program Director, Vascular Surgery University of Kentucky Medical Center Lexington, Kentucky, USA

Periprosthetic leak and rupture after endovascular repair of abdominal aortic aneurysm: The significance of device design for long-term results

Influence of patient selection and IFU compliance on outcomes following EVAS

Disclosures. EVAR follow-up: actual recommendation. EVAR follow-up: critical issues

Abdominal and thoracic aneurysm repair

EVAS is Associated with Lower All-Cause Mortality

More than twenty years after its introduction, endovascular

SANWICH TECHNIQUE TO REDUCE COMPLICATIONS WHEN TREATING BILATERAL INTERNAL ILIAC ARTERY

2015 Clinical Update Endovascular Systems for AAA Repair

Abdominal Aortic Aneurysm (AAA)

The Auckland Experience with the Nellix EVAS System. Andrew Holden, MBChB, FRANZCR

Endologix PowerWeb System EPW?

Indications for use. Contraindications within the United States

Nellix Endovascular System: Clinical Outcomes and Device Overview

Obesity, Scaring, Access in EVAR. Kiskinis D, Melas N, Ktenidis K. 1 st Department of Surgery Aristotle University of Thessaloniki, Greece

Development of a Branched LSA Endograft & Ascending Aorta Endograft

Introducing the GORE TAG Conformable Thoracic Stent Graft with ACTIVE CONTROL System

Treating very short necks ( 4mm <10mm) using the Endurant stent graft + EndoAnchors: 1-year results and current insights

Case Report Early and Late Endograft Limb Proximal Migration with Resulting Type 1b Endoleak following an EVAR for Ruptured AAA

EndoVascular Aneurysm Sealing (EVAS) with Nellix

MODERN METHODS FOR TREATING ABDOMINAL ANEURYSMS AND THORACIC AORTIC DISEASE

Abdominal Aortic Aneurysms. A Surgeons Perspective Dr. Derek D. Muehrcke

Clinical experience with a new thoracic stent graft system (Ankura TM ). Procedural analysis, 30 days and 6-month results in a single center study

Management of Endoleaks. Michael Meuse, M.D Vascular and Interventional Radiology 12/14/09

-vita THORACIC 3G. Stent Graft System SOLUTIONS FOR VASCULAR DISEASE

Chungbuk Regional Cardiovascular Center, Division of Cardiology, Departments of Internal Medicine, Chungbuk National University Hospital Sangmin Kim

The Endurant Stent Graft System

Predictors of abdominal aortic aneurysm sac enlargement after EVAR Longterm results from the ENGAGE Registry

EVAR Revision Setting - How can Heli-FX EndoAnchors improve the outcomes?

CHALLENGING ILIAC ACCESSES AND THROMBOSIS PREVENTION

Transcription:

The evolution of AORFIX AORFIX AAA Stent Graft now with the new AORFLEX Delivery System

The confident choice for the right angles AORFIX the only AAA stent graft approved for all angulations from 0 90, now even easier to use with AORFLEX Delivery System Enhanced navigation in tortuous anatomy Reduced risk of vessel damage during AORFLEX delivery system insertion and withdrawal Improved manoeuvring and reduced friction between the delivery system and vessel walls Minimised risk of vessel trauma and wall abrasion Greater deployment control with reduced deployment forces Excellent torque, pushabililty and trackability High kink resistance and flexibility Reduced risk of sheath stretch in complex anatomies AORFLEX tracks consistently and easily, even when accessing tortuous iliacs and high neck angulations Excellent angiographic visibility Excellent torque and kink resistance Reduced friction and enhanced navigation with hydrophilic coating Gentle taper for trackability in tortuous vessels Optimal flexibility with interlocking spine AORFIX AAA Stent Graft with AORFLEX Delivery System

NEW AORFLEX Delivery System Enhanced control for effective deployment, specifically for AAA patients with complex anatomies Confidence with precise positioning Platinum Iridium radiopaque marker with exceptional radiopacity designed for excellent angiographic visibility Greater confidence with enhanced placement accuracy Indicates accurate position of the sheath during deployment Disconnector control for release of AORFIX stent graft from the delivery system Push rod control to engage fixation hooks Distal stop Sheath control allows controlled step-by-step fishmouth and graft body deployment Initial 10 cm of sheath free of hydrophilic coating for improved grip Reduced blood loss with improved valve performance Proximal handle for delivery system stabilisation No hydrophilic coating Seam orientation marker ensures accurate anterior positioning prior to insertion The new wave of delivery for the right angles

Designed, tested, approved and proven to perform in all angles up to 90 Normal angulated neck Highly angulated neck Tortuous iliacs Highly angulated neck and tortuous iliacs Images courtesy of Musgrove Park Hospital, 2011 Clinical practice is increasingly moving towards endovascular aneurysm repair and away from surgery, and devices that both perform well and are flexible such as AORFIX will play an important role as a highly effective option for patients with more complex anatomy and increase the number of patients for whom a non-operative AAA repair is possible. Dr Gray, Cardiovascular Research Foundation, New York; ISET Symposium 2012 Clinical performance based on evidence Retrospective AORFIX Data Retrieval ( RADAR ) registry results Reported Complications All Cases Neck Angle <60 Neck Angle 60 Elegible cases for 3 year follow up 538 228 138 Stent migration 0.4% 0.4% 0.7% Wire fracture 0.2% 0.0% 0.7% Type 1 endoleaks 0.0% 0.0% 0.0% Type 3 endoleaks 0.0% 0.0% 0.0% Number of re-interventions 2.1% 0.7% 0.9% Voluntary international registry includes data from 1498 cases with a follow up range up to 9 years (March 2012). The device s flexible design allows safe and accurate aneurysm sac exclusion in patients with highly challenging anatomy. Balasubramaniam, K., Hardman, J., Horrocks, M., Bulbulia, R. 2009. The advantages of AORFIX for endovascular repair of abdominal aortic aneurysm. Journal of Cardiovascular Surgery, 50, 2, 139-143 Excellent sac shrink age performance 30 Days to 12 Months % of Patients All Patients High Angle Patients 20% 10% 0% -30-27 -24-21 -18-15 -12-9 -6-3 0 3 6 9 Sac Diameter Change (mm) Why compromise? Choose AORFIX 62.4 % of all patients had sac shrinkage 5 mm or more 59.2 % of patients with neck angles >60 had sac shrinkage 5 mm or more Data on File

AORFIX Sizing For more information about sizing, please visit www.lombardmedical.com Smartphone users can access this information by scanning this code. SMA to distal origin of renal artery with 10% oversizing fishmouth is 7 12 mm deep. Take care if SMA is 10 mm from inf. renal artery Measure a range of diameters in the neck. Oversize largest diameter by 10% D1 Graft length from decided proximal landing zone to aortic bifurcation minus L1about 10 30 mm Position cannulation socket 10 30 mm above level of aortic bifurcation Diameter at cannulation socket and aortic bifurcation should be 24 x 12 mm Cannulation socket to distal landing zone position* L2 Cannulation socket to distal landing zone L3position* Diameter at D2 distal landing zone. Oversize by 10% Diameter at distal landing zone. Oversize D3by 10% * See our step-by-step guide at www.lombardmedical.com DISCLAIMER: It is the responsibility of the clinician to assess the suitability of AORFIX for their patient by referring to the Instructions for Use (IFU). The information included in this brochure should not be used as an EVAR training tool and does not replace clinical expertise. Clinicians should understand the principles related to endovascular stent grafts and be trained in EVAR techniques prior to commencing any EVAR procedure.

Championing complex EVAR treatment The 1st and only AAA stent graft approved for use with 0 90 angles * Effective sealing even in high angulations shown to reduce Type I endoleaks 1 Precise positioning with high visibility Tantalum radiopaque markers 0-90º Secure fixation 8 mm infrarenal fixation and seal zone with 8 cat s claw hooks Supreme flexibility in angles up to 90 with helical stent structure Minimised limb occlusion 2 with highly flexible limbs Excellent durability electropolished nitinol wire Exceptional contouring to landing zones with woven polyester fabric Not for Distribution in the USA. Lombard Medical Limited, Lombard Medical House 4 Trident Park, Didcot, Oxon, OX11 7HJ, UK Tel: +44 (0)1235 750800 Fax: +44 (0)1235 750879 www.lombardmedical.com Registered in England and Wales Reg No. 2998639 2012 by Lombard Medical Limited. All rights reserved. AORFIX and AORFLEX are trademarks of Lombard Medical Limited. *CE Marked, please refer to current AORFIX IFU. Data on file Lombard Medical Limited. PN01574 A 1. AbuRahma, A. F., Campbell, J., Stone, P. A., Nanjundappa, A., Scott Dean, L., Keiffer, T., & Emmett, M. (2010). Early and late clinical outcomes of endovascular aneurysm repair in patients with an angulated neck. Vascular, 18(2), 93-101. 2. Weale AR, Balasubramaniam K, Hardman J, Horrocks M. Use of the AORFIX stent graft in patients with tortuous iliac anatomy. J Cardiovasc Surg, 2010 Aug;51(4):461-6.