JETSTREAM Atherectomy System DELIVERING VERSATILITY TO RESTORE FLOW

Similar documents
Atherectomy: Jetstream and Directional. George S. Chrysant, M.D.

BTK Case Studies Joseph Cardenas, MD AZ Heart & Vascular, Yuma, AZ

ROTABLATORTM. Peripheral. Rotational Atherectomy System. Quick Reference Cards

The Utility of Atherectomy and the Jetstream Atherectomy System

2.4 mm deflecting 2.4 mm tracking Above the knee Phoenix Below the knee 2.2 mm tracking 1.8 mm tracking

William A. Gray MD System Chief of Cardiovascular Services, Main Line Health President, Lankenau Heart Institute Wynnewood, PA USA

TurboHawk. Plaque Excision System

Device Evolution. Atherectomy: Where Do We Stand After 12 Years Since FDA Clearance. Where Do We Stand? 4/18/2015

Calcium Removal and Plaque Modification in the Era of DEB and Contemporary Stenting for Femoro- Popliteal Disease

The SplitWire Percutaneous Transluminal Angioplasty Scoring Device. Instructions for Use

MAXIMIZE RADIAL SOLUTIONS TO PERIPHERAL CHALLENGES

DISRUPT PAD. (( Data Summary )) DISRUPT PAD Data Summary SPL Rev. B 2016 Shockwave Medical Inc. All rights reserved.

Sustained Release. Superior Results.

There are multiple endovascular options for treatment

System.

LIBERTY 360 Study. 15-Jun-2018 Data 1. Olinic Dm, et al. Int Angiol. 2018;37:

Excimer Laser for Coronary Intervention: Case Study RADIAL APPROACH: CORONARY LASER ATHERECTOMY FOR CTO OF THE LAD FOLLOWED BY PTCA NO STENTING

DEPARTMENT OF HEALTH & HUMAN SERVICES Public Health Service

Figure 1: Revolution TM Peripheral Atherectomy System Diagram. Table 1: Revolution TM Peripheral Atherectomy System Specifications Minimum Burr

REBEL. Platinum Chromium Coronary Stent System. Patient Information Guide

Ruby Coil. Large Volume Detachable Coils

Phoenix Atherectomy System Product Overview /LB

Update on Tack Optimized Balloon Angioplasty (TOBA) Below the Knee. Marianne Brodmann, MD Medical University Graz Graz, Austria

Appropriate Device Selection for Endovascular Procedures

Christian Wissgott MD, PhD Assistant Director, Radiology Westküstenkliniken Heide

Turbo-Power. Laser atherectomy catheter. The standard. for ISR

IVUS Guided Case Review Case Performed by Frank R. Arko III, MD Charlotte, NC

Chronic Total Occlusion (CTO) Technologies

Use of Laser In BTK Disease (CLI)

DURABLE. CONSISTENT. SAFE. IN.PACT Admiral Drug-Coated Balloon

Indications. The AngioVac cannula is intended for use as a venous drainage cannula and for the removal of fresh, soft thrombi or emboli

Assurant Cobalt Iliac BALLOON EXPANDABLE STENT SYSTEM

CLARIVEIN INFUSION CATHETER

Management of Acute DVT Extending From the Tibial Veins to the Common Iliac Vein Using the AngioJet Thrombectomy System

Every heartbeat is precious. Thanks to you, he ll have 100 million more.

Instructions for Use Reprocessed LASSO Circular Mapping Diagnostic Electrophysiology (EP) Catheter

AXS Catalyst Distal Access Catheter

Access More Patients. Customize Each Seal.

1 Description. 2 Indications. 3 Warnings ASPIRATION CATHETER

ENHANCING YOUR OPTIONS

When and how to use distal protection devices for lower extremity revascularization. Peter A. Schneider, MD Kaiser Foundation Hospital, Honolulu

CLI Treatment Using Long and Scoring Balloons

Lotus transducer Instructions for use

Dealing with Calcification in BTK Arteries: Is Lithoplasty the Answer?

Rotarex mechanical thrombectomythe first line option for thrombotic occlusions?

Plaque Excision Infrainguinal PAD An update on this nonstenting alternative, with intermediate-term results of the ongoing TALON Registry.

Solitaire FR Revascularization Device

Update on the OPTIMIZE BTK Trial. Marianne Brodmann, MD Division of Angiology Medical University Graz, Austria

Peripheral Intravascular Lithotripsy (IVL) Catheter Instructions for Use (IFU)

Access strategy for chronic total occlusions (CTOs) is crucial

MICHAEL R. JAFF, DO MASSACHUSETTS, UNITED STATES. Medtronic Further. Together

Rationale and algorithm for below-the-knee acute gain optimization

The Role of Lithotripsy in Solving the Challenges of Vascular Calcium. Thomas Zeller, MD

DISRUPT CAD. Todd J. Brinton, MD Clinical Associate Professor of Medicine Adjunct Professor of Bioengineering Stanford University

Endovascular Repair of Combined Occluded Femoral and Popliteal Arteries

The Art of. Flow Restoration. Ikazuchi Zero. Semi-Compliant PTCA Balloon OVERVIEW CROSSABILITY LOW PROFILE CASE STUDY CODES

22F coil-reinforced cannula. Designed with a balloon actuated, expandable funnel shaped distal tip

Instructions for Use 1

Effectiveness of IVUS in Complex Cases

Talent Abdominal Stent Graft

Peripheral artery disease (PAD) is a major cause of

Chronic Total Occlusion (CTO) Technologies. Re-open vital channels

Experience With Atherectomy and DCBs

How do I use mechanical debulking for the treatment of arterial occlusions

A Guide for Patients Living with a Biliary Metal Stent

Crossing the Long SFA CTO

Single Pass MCA Revascularization with Trevo

Shockwave Medical Lithoplasty. Thomas Zeller MD Universitäts-Herzzentrum Freiburg & Bad Krozingen, Germany

Rotarex mechanical debulking: The Leipzig experience in patients

Instructions for Use Cordis PRECISE PRO Rx Nitinol Stent System

CHALLENGING ILIAC ACCESSES AND THROMBOSIS PREVENTION

New Modalities and Advanced Techniques: The Role of Crossing Devices and Atherectomy

Lessons for Successful Subintimal Angioplasty in SFA CTO

PERFORMANCE YOU CAN TRUST. EverFlex Self-expanding Peripheral Stent with Entrust Delivery System

LeMaitre Embolectomy Catheter

NON-COMPLIANT PTCA RAPID EXCHANGE DILATATION CATHETER

Fabrizio Fanelli, MD, EBIR Director Vascular and Interventional Radiology Department "Careggi " University Hospital Florence - Italy

Directions For Use. All directions should be read before use

ULTRA ICE PLUS ULTRASOUND IMAGING CATHETER. Know where you are. See what you want to avoid.

61% SvO 2. Clarity. Simplified.

Calcified lesions optimal treatment

Future Algorithm for Lower Extremity Revascularization: Where Does Vessel Prep Fit?

Advanced Innovation for Exceptional Performance

OCT guided procedures in peripheral intervention

Guidewire Selection. Making the Most Out of My Guidewire: LINC 2016: Leipzig Interventional Course Leipzig, Germany January 26-29, 2016

Polyurethane Dual Lumen Occlusion Catheter English Instructions for Use. Polyurethane Dual Lumen Occlusion Catheter

TriVascular Ovation Prime Abdominal Stent Graft System

Excimer Laser angioplasty for femoro-popliteal disease. Sendai Kousei Hospital, Tokyo Kamata Hospital Naoto Inoue MD, FSCAI, FJCC, FAHA

Atrium Advanta V12. Balloon Expandable Covered Stents

NIRxcell CoCr Coronary Stent System

LINEAR 7.5Fr. IAB Catheter

Cardioplegia Circuit Products { ANTEGRADE}

1 Comparison of Warfarin and Aspirin for Symptomatic Intracranial Arterial Stenosis. N Engl J Med 352;13, March 31, 2005

Pipeline Embolization Device

Challenging anatomies demand versatility.

PTA Balloon Dilatation Catheter

Koen Keirse, MD RZ Tienen, Belgium

Pruitt Irrigation Occlusion Catheter. English Instructions for Use. Pruitt Irrigation Occlusion Catheter

ER REBOA Catheter. Instructions for Use

OCT Guided Atherectomy: Initial Results of the VISION Trial Using the Pantheris Catheter. Patrick Muck, MD

Transcription:

JETSTREAM Atherectomy System DELIVERING VERSATILITY TO RESTORE FLOW

DISCOVER THE VALUE OF VERSATILITY Versatility means not having to guess the morphology! Peripheral arterial lesions can present with a range of morphologies from soft thrombus to plaque and difficult calcification often in the same vessel. The Jetstream Atherectomy System is indicated for both thrombectomy and atherectomy and has demonstrated its ability to deliver luminal gain in soft, hard and calcified lesions. 1,2 Versatility means not having to switch in the middle of a procedure! The Jetstream Atherectomy System offers the XC Catheter for above the knee and the SC Catheter for below the knee. In addition, the XC series has expandable blade technology that can deliver two lumen sizes with the same catheter. FEATURE Labeling Indication Active Aspiration Lesion Type Atherectomy Thrombectomy Front Cutting / Rotational Device Concentric Lumens Differential Cutting Expandable Blade Technology Total Occlusions Thrombus Calcium Soft Plaque Fibrous Plaque Jetstream Orbital Directional Laser BENEFIT Complex lesions and total occlusion often contain mixed morphology lesions, requiring a device capable of managing it all. Aspiration of liberated debris may minimize the risk of distal embolization. Total occlusions are common in PAD, front cutting enables engagement of tightest lesions. Concentric lumens facilitate straight line laminar flow. Differential cutting targets only the plaque, minimizing the risk of vessel damage. Expandable blades deliver more versatility, facilitating treatment from SFA to TPT. Peripheral arterial disease rarely manifests as a single lesion type. A mix of disease morphologies is common, driving the need for a single device capable of addressing them all.

RESTORE FLOW WITH THE MOST VERSATILE ATHERECTOMY SYSTEM AVAILABLE Treat It All with One Device 1 From thrombus to difficult calcium, both above and below the knee. Dual Indication Both atherectomy and thrombectomy from the same catheter. CTOs and Tight Stenoses True front-cutting tips follow the guidewire through tight lesions without pre-dilation. Prior to treatment, IVUS shows tight, irregular lesion Increase / Remodel Lumen Area Rotational design supports concentric lumens, which facilitate laminar flow. Remove the Debris The Jetstream System is the only atherectomy device with continuous active aspiration. After treatment with Jetstream XC catheter, IVUS shows concentric luminal gain Images show result from one case, results may vary.

EFFECTIVELY TREAT LESIONS ABOVE AND BELOW THE KNEE Jetstream XC Atherectomy Catheter 2.4 mm 3.4 mm ATK 120cm 7F 0.014 2.4mm 3.4mm 70K rpm Jetstream XC Atherectomy Catheter 2.1 mm 3.0 mm 135cm 7F 0.014 2.1mm 3.0mm 70K rpm Jetstream SC Atherectomy Catheter 1.5 mm 145cm 7F 0.014 1.5mm 73K rpm BTK Jetstream SC Atherectomy Catheter 1.6 mm 145cm 7F 0.014 1.6mm 73K rpm

ERGONOMIC, SINGLE OR DUAL-OPERATOR DESIGN The lighter, more ergonomic XC and SC catheters are designed to enhance ease of use. Control buttons are integrated into the mouse, which can be used either in the pod or removed for remote activation. The improved Wire GARD simplifies wire management. Wire GARD activation button on side of POD Wire GARD integrated into POD Lighter and more ergonomically designed control POD Control buttons integrated into mouse Mouse embedded within POD Ergonomic design with 32% smaller* POD enhances user experience Intuitive user interface facilitates single or dual operator use Improved wire GARD* simplifies wire management Advanced package and POD design reduces environmental footprint *As compared to previous, G3 version catheters.

Jetstream JETWIRE COMPONENTS CONSOLE ordering information Product Description Catalog Number Product Description Catalog Number Jetstream SC Atherectomy Catheter 1.5 mm PV311F Jetstream JETWIRE PV014300 Jetstream SC Atherectomy Catheter 1.6 mm Jetstream XC Atherectomy Catheter 2.4 mm / 3.4 mm Jetstream XC Atherectomy Catheter 2.1 mm / 3.0 mm PV3116F PV41340 PV31300 1 Zeller T et al. One-year outcome of percutaneous rotational atherectomy with aspiration in infrainguinal peripheral arterial occlusive disease: the multicenter pathway PVD trial. J Endovasc Ther. 2009 Dec;16(6):653-62. 2 http://www.eventscribe.com/2013/posters/isetcio/splitviewer. asp?pid=mtewntg2mju2 Jetstream Atherectomy System Can Remove Superficial Calcium in Severely Calcified Peripheral Arteries CAUTION: Federal law (USA) restricts this device to sale by or on the order of a physician. Rx only. Prior to use, please see the complete Directions for Use for more information on Indications, Contraindications, Warnings, Precautions, Adverse Events, and Operator s Instructions. Jetstream System INDICATIONS: The Jetstream System is intended for use in atherectomy of the peripheral vasculature and to break apart and remove thrombus from upper and lower extremity peripheral arteries. It is not intended for use in coronary, carotid, iliac or renal vasculature. CONTRAINDICATIONS: No known contraindications. WARNINGS: The Jetstream Catheter and Control Pod may only be used with the PV Console. PRECAUTIONS: Do not manipulate the Catheter against resistance unless the cause for that resistance has been determined. Use only listed compatible guidewires and introducers with the Jetstream System. The use of any supplies not listed as compatible may damage or compromise the performance of the Jetstream System. Prior to use of the Jetstream System, confirm the minimum vessel diameter proximal to the lesion per the following table: Jetstream SC Atherectomy Catheter 1.6 : Minimum Vessel diameter proximal to lesion: 2.5mm Jetstream SC Atherectomy Catheter 1.5: Minimum Vessel Diameter Proximal to Lesion 2.75 mm Jetstream XC Atherectomy Catheter 2.1/3.0: Minimum Vessel Diameter, Blades Down 3.0 mm Minimum Vessel Diameter, Blades Up 4.0 mm Jetstream XC Atherectomy Catheter 2.4/3.4: Minimum Vessel Diameter, Blades Down 3.5 mm Minimum Vessel Diameter, Blades Up 4.5 mm ADVERSE EVENTS: Potential adverse events associated with use of this device and other interventional catheters include, but are not limited to the following (alphabetical order): Abrupt or sub-acute closure Amputation Bleeding complications, access site Bleeding complications, non-access site Death Dissection Distal emboli Hypotension Infection or fever Perforation Restenosis of the treated segment Vascular complications which may require surgical repair Thrombus Vasospasm Jetstream PV Console INDICATIONS: The PV Console is designed for use only with the Jetstream Catheter and Control Pod. See the current revision of the applicable Catheter and Control Pod Instructions for Use for further information. PRECAUTIONS AND WARNINGS: WARNING: To avoid the risk of electric shock, this equipment must only be connected to a supply mains with protective earth. Do not open either pump door during operation of the System. Doing so could result in loss of aspiration and/or infusion and will halt device activation. Ensure the PV Console display is visible during the entire procedure. Observe normal safety practices associated with electrical/electronic medical equipment. Avoid excessive coiling or bending of the power cables during storage. Store the PV Console using appropriate care to prevent accidental damage. Do not place objects on the PV Console. Do not immerse the PV Console in liquids. Jetstream is a registered or unregistered trademark of Boston Scientific Corporation or its affiliates. All other trademarks are property of their respective owners. Peripheral Interventions 300 Boston Scientific Way Marlborough, MA 01752-1234 www.bostonscientific.com To order product or for more information contact customer service at 1..272.1001. 2015 Boston Scientific Corporation or its affiliates. All rights reserved. PI-27312-AA JAN2015