BP Pump 2. Non-Invasive Blood Pressure Simulator and Tester. Technical Data. Key features

Similar documents
ProSim 3 and 2 Vital Signs Simulators

ProSim 3 and 2. Vital Signs Simulators

Fundamentals of Pulse Oximetry

ProSim 4 Vital Signs Simulator

medsim 300B Patient Simulator

Rigel UNI-SiM Lite. The most cost-effective patient simulator on the market. Key Features n Compact and cost-effective

Rigel UNI-SiM. The world s smallest integrated NiBP, SpO2 and patient simulator. Key Features n Compact and cost-effective

The HeartCheck TM PEN Handheld ECG Is your heartbeat slow, fast, or irregular? Are you at risk? Put your heart health in your own hands

SURETEST Torque Calibration System

Validity study of oscillometric blood pressure measurement devices using an oscillometric waveform simulator

A GUIDE TO OUR NIBP TECHNOLOGY

SURETEST Torque Calibration System

GSI TYMPSTAR PRO CLINICAL MIDDLE-EAR ANALYZER. Setting The Clinical Standard

ProSim 6/8. Users Manual. Vital Signs Simulator

Automated Blood Pressure Monitor

ProSim 8. Users Manual. Vital Signs Simulator

Testing the Accuracy of ECG Captured by Cronovo through Comparison of ECG Recording to a Standard 12-Lead ECG Recording Device

Infinity MCable -Masimo SET

VITAL SIGNS MONITORING. RVS-100/200 ri-vital. Vital Signs Patient Monitors

Monitoring Equipment. Blood Pressure Monitor Upper Arm Type: Image (Image not to scale)

ProSim 8 Vital Signs Simulator

CATCH A WAVE.. INTRODUCTION NONINVASIVE HEMODYNAMIC MONITORING 4/12/2018

Detection. personal. Now, you can optimize your personal workflow. Promega instruments and reagents integrate easily.

Cardiocap/5. GE Healthcare. The compact, all-in-one, critical care monitor. Features. Available options

ProSim 4. Users Manual. Vital Signs Simulator

Basic Dysrhythmia Interpretation

Device Equivalence Evaluation Form

MULTI-PARAMETER PATIENT SIMULATOR

Manual Defibrillators, Automatic External Defibrillators, Cardioversion, and External Pacing. D. J. McMahon cewood rev

medsim 300B Operators Manual Patient Simulator

Managing cardiovascular risk with SphygmoCor XCEL

ECG MACHINE KEC- Series

Blood Pressure Laboratory

Welch Allyn ABPM 6100S. Comprehensive blood pressure monitoring that brings patient comfort home.

Device Equivalence Evaluation Form

ACCESSORY GUIDE REV F

Natural performance. Introducing the BiPAP A30 - because ease of use and therapy efficacy are key to patient well-being

Measures 100 ppm to 100% water content. Precision titrant delivery system. Anti-diffusion burette tip. Built-in stirrer

Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems

Welcome to the S410. Blood Pressure System. Instruction Manual

Device Equivalence Evaluation Form

MANUAL BLOOD PRESSURE MONITOR BPM 168B Contents Blood Pressure Monitor Intended Use What is blood pressure?

Dräger Alcotest 5510 Alcohol Screening Device

microprocessor controlled eddy current brake Load / accuracy Watt, speed independent / according to DIN VDE

Aer ODE B3-20. Database System for GEX B3 Dosimetry. Aérial. Optical Dosimetry Equipment. (gamma and/or electron beam versions)

Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems with PVDF Sensor

Invasive Measurement of Blood Pressure

Atrial Fibrillation. Why It s Important. Updated on 2007 / 11 / 23. Microlife Corp ww.microlife.com. Page 1

Panorama. Arrhythmia Analysis Frequently Asked Questions

Biomedical Instrumentation E. Blood Pressure

Vital Signs Simulator

HI Total Acidity Mini Titrator for Water Analysis

ER75 Electro-Acoustic Ear Simulator. Operating Manual

Device Equivalence Evaluation Form

ISO 13485:2016 MEDICAL DEVICES QMS TRANSITION GUIDE

Company_Brochure_A5_ver1734.

Auto HbA1C ANALYZER HbA1LC HPLC 3660

Managing anti-hypertensive treatment with SphygmoCor XCEL

1 2 3 Based on the contents detailed below, assess the substantial equivalence to a legally marketed predicate device. In that case, the standards, et

104 Vital Signs Devices

SPECTRAL ANALYSIS OF LIFE-THREATENING CARDIAC ARRHYTHMIAS

BP210 BP250. Automatic Blood Pressure Monitor. Medical Diagnostic Device

MRI Ergometer Pedal. Medication free, load adjusted patient activation during MRI scans. Unique ergometer for MRI.

MPS450. Operators Manual. Multiparameter Simulator

Dräger Alcotest 6820 Alcohol Screening Device

CAMOSUN COLLEGE BIOLOGY 144 (2010) LABS

Hemodynamic Monitoring

BP Hour Ambulatory Blood Pressure Monitor. Medical Diagnostic Device

QUICK SETUP GUIDE SECULIFE DFBASE

The Electrocardiogram part II. Dr. Adelina Vlad, MD PhD

SENSATION and CS300 Smaller meets faster. IABP System

Indications The AED mode is to be used only on patients in cardiopulmonary arrest.

AUDIOLAB Two channel clinical audiometer. Tonal Audiometry Vocal Audiometry MASKING SISI ABLB Decay Test BEKESY

PORTO 2 VENT CPAP OS. Operator s Manual. PORTO 2VENT CPAP OS System Operator s Manual Part Number Rev I

TECHNOCARE MEDISYSTEMS

PowerLab LabTutor Systems

St. Jude Medical 8-Channel Adapter. Clinician's Manual

External Oscillatory Blood Pressure - EOBPTM

Advanced ICD Concepts

MAGPRO. Versatility in Magnetic Stimulation. For clinical and research use

CORONARY ARTERIES. LAD Anterior wall of the left vent Lateral wall of left vent Anterior 2/3 of interventricluar septum R & L bundle branches

TWO CHANNEL CLINICAL AUDIOMETER AUDIOSTAR PRO

AMBCO 2500 AUDIOMETER SYSTEM WITH FIVE YEAR WARRANTY

Effective Treatment for Obstructive Sleep Apnoea

Welch Allyn HScribe Holter Analysis System

Pulmonary Function Technologists (PFT) Detailed Content Outline

Blodtrycksmätare för indirekt blodtrycksmätning

H Series Pneumatic Screwdrivers and Nutrunners. Products and Solutions for Assembly

Defibrillator. BiomedGuy

Device Equivalence Evaluation Form

AMBULATORY BLOOD PRESSURE REPORT. Patient Name: Sample 2 - Systolic Hypertension Patient ID: Test Date: 15-Sep-2005

Manual Defibrillators, Automatic External Defibrillators, Cardioversion, and External Pacing

X Series Extensive Capabilities

EKG Abnormalities. Adapted from:

PACIFIC MEDICAL TRAINING Arrhythmia Interpretation

HI Titratable Acidity Mini Titrator for Fruit Juice Analysis

ISO INTERNATIONAL STANDARD. Implants for surgery Active implantable medical devices Part 2: Cardiac pacemakers

CARESCAPE Patient Data Module

Transcription:

BP Pump 2 Non-Invasive Blood Pressure Simulator and Tester Technical Data The BP Pump 2 provides dynamic blood-pressure simulations for testing adult and neonatal noninvasive blood pressure monitors, including both arm- and wrist-cuff types. The analyzer features a preset mode for simulation of most patient conditions and the capability to program user-defined simulations. BP Pump 2 tests for leaks, measures static pressure, generates pressure, and tests overpressure valves. For improved testing versatility, the analyzer s recently upgraded waveform test suite includes additional physiological selections. BP Pump 2 comes in two models: the standard BP Pump 2 L and the BP Pump 2 M, which features a high-accuracy pressure transducer. BP Pump 2 also includes an optional five-lead synchronized ECG simulations to test monitors that monitors patients ECG. Key features Dynamic simulations for arm- and wrist-cuff monitors Physiological waveform Internal pump for use in high- and low-pressure release verification, leak testing and pressure sourcing Preset mode for simulation of most patient conditions User-definable systolic and diastolic values, along with heart rate and pulse volume and user-defined autosequences Five-leads synchronized ECG simulation Internal cuff volume for basic device testing Respiratory artifacts, including spontaneous breathing and controlled ventilation Arrhythmia simulations, including premature atrial contractions #1 and #2, atrial fibrillation, and PVCs PC based ansur test automation system to standardize testing protocol and documentation High-accuracy pressure transducer (Bp Pump2 M version only) Dynamic pressure simulation repeatability within 2 mmhg at maximal pulse size independent of device under test

Specifications Pressure generation/measurement Static-pressure range 50 mmhg to 400 mmhg (53 kpa) Difference between target - 5 mmhg pressure and actual pressure Internal leak rate < 2 mmhg per minute with minimum volume of 300 cc Four respiratory artifacts 3 spontaneous breathing; controlled ventilation 3 adult wrist-cuff simulations Normal, Hyper, Hypo Pressure source Specified pressure generated from 50 mmhg to 400 mmhg in selectable increments of 1 mmhg Pressure gauge Static pressure measured from 0 mmhg to 400 mmhg at the pressure port Pressure relief rest Test for the NIBPM pressure relief valve (0 mmhg to 400 mmhg) with display of peak pressure Neonate internal cuff Internal neonate cuff; four standard neonate pressures simulations Neonate simulations Cuff #1 Blood pressure: 35/15 Cuff #2 Blood pressure: 60/30 Cuff #3 Blood pressure: 80/50 Cuff #4 Blood pressure: 100/70 Normal sinus rhythm and arrhythmias BP and ECG Healthy heart, weak pulse, mild exercise strenuous exercise, obese subject, geriatric subject, tachycardia, bradycardia irregular pulse BP and ECG Premature atrial contractions # 1, premature atrial contractions # 2, premature ventricular contractions, atrial fibrillation and PVCs User-definable simulations User-definable systolic and diastolic values, along with heart rate and pulse volume Ranges Systolic pressure range 20 mmhg to 250 mmhg Diastolic pressure range 10 mmhg to 200 mmhg Dynamic NIBP simulation Within 2 mmhg (at maximal pulse size independent of device under test) repeatability Heart rate 30 BPM to 250 BPM Pulse volume 0.1 cc to 2.4 cc in increments of 0.1 cc Simulation parameters performance Max pulse volume 2.4 cc Max heart rate 200 BPM at 2.4 cc pulse volume; 250 BPM at 1.2 cc pulse volume Internal neonatal cuff volume 20 cc Internal adult cuff volume 310 cc (including NN volume) Heart rate setting accuracy ± 1 BPM Simulation units kpa and mmhg (user selectable) Pressure leak test The pressure port is pressurized from 0 mmhg to 400 mmhg and keeps track of the pressure loss over time. Peak pressure and present pressure are displayed at all times; leak rate is displayed when it is available. Autosequences Nine autosequences are provided for four tests and up to five simulations 2 Fluke Biomedical BP Pump 2 Non-Invasive Blood Pressure Simulator and Tester

Electrical ECG (optional) Signals RA, LA, RL, LL, V Waveform Lead II Amplitude 1 mv peak (± 10 %) NIBP peripheral pulse synchronized with ECG signal Connections Optional external ECG adapter physiological synchronization with NIBP Heart rate for NIBP simulations Heart rate accuracy + 1 BPM Except for the following Patient condition weak pulse, tachycardia, obese, geriatric: + 1 % + 1 BPM Patient condition mild exercise: + 1.5 % + 1 BPM Patient condition strenuous exercise: + 3 % + 1 BPM Serial port Bidirectional RS-232 port; baud rate of 9600 with no parity, one stop bit, and eight data bits Pressure measurement Pressure-measurement units kpa, mmhg, cmh 2 0, cmh 2 O and psi (user selectable) Range 0 mmhg to 400 mmhg Accuracy, BP Pump 2 L 0 mmhg to 300 mmhg: ± 0.5 % of reading ± 1 mmhg (basic model) 301 mmhg to 400 mmhg: ± 2 % of reading Accuracy, BP Pump 2 M ± 0.7 mmhg (0.09 kpa) throughout range (high-accuracy version) Parallel port 25-pin female connector, with D-subminiature style and pinouts conforming to IBM PC printer port (unidirectional), HP and ASCII printers Sample adult arm-cuff simulation (standard parameters) Standard set of blood pressures BP #1 Blood pressure: 120/80 (93) Pulse volume: 0.68 cc BP #2 Blood pressure: 150/100 (116) Pulse volume: 0.65 cc BP #3 Blood pressure: 200/150 (166) Pulse volume: 0.6 cc BP #4 Blood pressure: 255/195 (215) Pulse volume: 0.55 cc BP #5 Blood pressure: 60/30 (40) Pulse volume: 0.75 cc BP #6 Blood pressure: 80/50 (60) Pulse volume: 0.7 cc BP #7 Blood Pressure: 100/65 (76) Pulse volume: 0.69 cc 3 Fluke Biomedical BP Pump 2 Non-Invasive Blood Pressure Simulator and Tester

Patient condition simulations Healthy heart Blood pressure: 120/80 mmhg (93 MAP) Heart rate: 75 BPM Pulse volume: 0.7 cc Weak pulse Blood pressure: 110/80 (90) Heart rate: 95 BPM Pulse volume: 0.3 cc Mild exercise #1 Blood pressure: 140/90 (106) Pulse volume: 1.1 cc Strenuous exercise #2 Blood pressure: 140/90 (106) Heart rate: 162 BPM Pulse volume: 1.4 cc Obese subject Blood pressure: 120/80 (93) Heart rate: 90 BPM Pulse volume: 0.4 cc Geriatric subject Blood pressure: 150/110 (12) Heart rate: 95 BPM Pulse volume: 0.4 cc Tachycardia Blood pressure: 120/105 (110) Heart rate: 130 BPM Pulse volume: 0.3 cc Bradycardia Blood pressure: 120/60 Heart rate: 45 BPM Pulse volume: 1.1 cc Arrhythmia simulations Premature atrial cont. #1 Blood pressure: 138/53 mmhg (81 MAP) BPM Premature atrial cont. #2 Blood pressure: 144/64 (90) Heart rate: 83 BPM Premature ventricular cont. Blood pressure: 118/61 (80) Heart rate: 83 BPM Atrial Fib and PVCs Blood pressure: 139/72 (94) Heart rate: 91 BPM Respiratory artifacts Spontaneous breathing #1 Blood pressure: 138/65 mmhg (89 MAP) Heart rate: 104 BPM Spontaneous breathing #2 Blood pressure 149/65 (93) Heart rate: 105 BPM Spontaneous breathing #3 Blood pressure: 112/47 (68) Heart rate: 86 BPM Controlled ventilation Blood pressure 132/44 (73) Heart rate 98 BPM Pulse volume Varies 4 Fluke Biomedical BP Pump 2 Non-Invasive Blood Pressure Simulator and Tester

Wristsimulations Simulation #1 Blood pressure 120/80 (93) BPM Pulse volume: 0.5 cc Simulation #2 Blood pressure 160/100 (120) BPM Pulse volume: 0.5 cc Simulation #3 Blood pressure: 80/55 (63) BPM Pulse volume: 0.5 cc Temperature Operating 15 C to 40 C (59 F to 104 F) Storage -20 C to 65 C (-4 F to 149 F) Relative humidity 90 max Display Bright, large 4-line x 40-character alphanumeric display with back lighting Dimensions (WxDxH) 25.4 cm x 25.4 cm x 12.7 cm (10 in x 10 in x 5 in) Weight 3.4 kg (7.5 lb) Ordering information Model BP Pump 2 L Non-Invasive Blood Pressure Analyzer (standard pressure transducer) BPPUMP2L-US120V United States, 120 V BPPUMP2L-AUS250V Australia, 250 V BPPUMP2L-DEN250V Denmark, 250 V BPPUMP2L-SHK250V Shuko, 250 v BPPUMP2L-ISR250V Israel, 250 V BPPUMP2L-ITAL250V Italy, 250 V BPPUMP2L-IND250V India, 250 V BPPUMP2L-SWZ250V Switzerland, 250 V BPPUMP2L-UK250V United Kingdom, 250 V BPPUMP2L-BRAZ250V Brazil, 250 V BP Pump 2 M Non-Invasive Blood Pressure Analyzer (high-accuracy pressure transducer) BPPUMP2M-US120V United States, 120 V BPPUMP2M-AUS250V Australia, 250 V BPPUMP2M-DEN250V Denmark, 250 V BPPUMP2M-SHK250V Shuko, 250 V BPPUMP2M-ISR250V Israel, 250 V BPPUMP2M-ITAL250V Italy, 250V BPPUMP2M-IND250V India, 250 V BPPUMP2M-SWZ250V Switzerland, 250 V BPPUMP2M-UK250V United Kingdom, 250 V BPPUMP2M-BRAZ250V Brazil, 250 V BPPM2M/ECG-NIM (Includes a BPPUMP2 M - AUS250V, a ECG Adapter Block, 100 ml and 500 ml rigid aluminum chambers and a manual pressure pump (700PMP)) BPPM2M-NIM (Includes a BPPUMP2 M -AUS250V, 100 ml and 500 ml rigid aluminum chambers and a manual pressure pump (700PMP)) BP Pump 2 L Non-Invasive Blood Pressure Analyzer with Test Automation (standard pressure transducer) TA-BPPMP2L-US United States, 120 V TA-BPPMP2L-AUS Australia, 250 V TA-BPPMP2L-DEN Denmark, 250 V TA-BPPMP2L-SHK Shuko, 250 v TA-BPPMP2L-ISR Israel, 250 V TA-BPPMP2L-ITAL Italy, 250 V TA-BPPMP2L-IND India, 250 V TA-BPPMP2L-SWZ Switzerland, 250 V TA-BPPMP2L-UK United Kingdom, 250 V TA-BPPMP2L-BRAZ Brazil, 250 V BP Pump 2 M Non-Invasive Blood Pressure Analyzer with Test Automation (high-accuracy pressure transducer) TA-BPPMP2M-US United States, 120 V TA-BPPMP2M-AUS Australia, 250 V TA-BPPMP2M-DEN Denmark, 250 V TA-BPPMP2M-SHK Shuko, 250 v TA-BPPMP2M-ISR Israel, 250 V TA-BPPMP2M-ITAL Italy, 250 V TA-BPPMP2M-IND India, 250 V TA-BPPMP2M-SWZ Switzerland, 250 V TA-BPPMP2M-UK United Kingdom, 250 V TA-BPPMP2M-BRAZ Brazil, 250 V BP Pump 2 L Non-Invasive Blood Pressure Testing Bundles (with 5 leads ECG Block) BPPM2L/ECG-US United States, 120 V BPPM2L/ECG-AUS Australia, 250 V BPPM2L/ECG-DEN Denmark, 250 V BPPM2L/ECG-SHK Shuko, 250 v BPPM2L/ECG-ISR Israel, 250 V BPPM2L/ECG-ITAL Italy, 250 V BPPM2L/ECG-IND India, 250 V BPPM2L/ECG-SWZ Switzerland, 250 V BPPM2L/ECG-UK United Kingdom, 250 V 5 Fluke Biomedical BP Pump 2 Non-Invasive Blood Pressure Simulator and Tester

Quick NIBP monitor testing bundles PS420/DPM1B Bundle PS420/DPM1B Bundle Kit (includes PS420, DPM1B, all accessories, and a custom carrying case) PS410/DPM1B Bundle PS410/DPM1B Bundle Kit (includes PS410, DPM1B, all accessories, and a custom carrying case) PRINTR414-SHK220V Printer, Seiko DPU-414-30B, 220 V power supply 61096 Printer, 120 V power supply 61097 Printer, 220 V power supply 97116 Printer Paper (7 rolls min) 75034 Serial Cable, D9M-D9F 5215-0269FG Adult Cuff Mandrel Spacer Block (three required) 5215-0268FG Adult Cuff Mandrel End Block (two required) 5027-0203FG Neonatal/External Cuff Mandrel (truncated plastic cylinder diameters: 7.6 cm, 10 cm, and 14 cm) 98175FG Wrist Cuff Mandrel (adult) BPPM2M-2001 500 ML Rigid Aluminum Chamber for NIBP Testing BPPM2M-2002 100 ML Rigid Aluminum Chamber for NIBP Testing 700PMP External Pressure Pump Standard accessories 2780003FG Accessory Kit (tubings and fittings) Operators Manual Power Cord (country specific) Optional accessories ANSUR BP PUMP 2 Ansur BP Pump 2 Plug-in 5022010 Soft-Sided Vinyl Carrying Case 2780512FG ECG Adapter Block (allows simulation of 5-lead ECG waveforms) 71072 Parallel Printer Cable, D25M-C36M PRINTR/414-US120V Printer, Seiko DPU-414-30B, 120 V power supply About Fluke Biomedical Fluke Biomedical is the world s leading manufacturer of quality biomedical test and simulation products. In addition, Fluke Biomedical provides the latest medical imaging and oncology quality-assurance solutions for regulatory compliance. Highly credentialed and equipped with a NVLAP Lab Code 200566-6 accredited laboratory, Fluke Biomedical also offers the best in quality and customer service for all your equipment calibration needs. Today, biomedical personnel must meet the increasing regulatory pressures, higher quality standards, and rapid technological growth, while performing their work faster and more efficiently than ever. Fluke Biomedical provides a diverse range of software and hardware tools to meet today s challenges. Fluke Biomedical Regulatory Commitment As a medical test device manufacturer, we recognize and follow certain quality standards and certifications when developing our products. We are ISO 9001 and ISO 13485 medical device certified and our products are: CE Certified, where required NIST Traceable and Calibrated UL, CSA, ETL Certified, where required NRC Compliant, where required 6 Fluke Biomedical BP Pump 2 Non-Invasive Blood Pressure Simulator and Tester Fluke Biomedical. Better products. More choices. One company. Fluke Biomedical 6045 Cochran Road Cleveland, OH 44139-3303 U.S.A. Fluke Biomedical Europe Science Park Eindhoven 5110 5692EC Son, The Netherlands For more information, contact us: In the U.S.A. (800) 850-4608 or Fax (440) 349-2307 In Europe/M-East/Africa +31 40 267 5435 or Fax +31 40 267 5436 From other countries +1 (440) 248-9300 or Fax +1 (440) 349-2307 Email: sales@flukebiomedical.com Web access: www.flukebiomedical.com 2007-2010 Fluke Biomedical. Specifications subject to change without notice. Printed in U.S.A. 11/2010 2817822D D-EN-N Modification of this document is not permitted without written permission from Fluke Corporation.