Code Blue III PLUS Emergency Care Simulators Our Code Blue III system teaches ALS skills using realistic code scenarios. Each step you take is monitored by software providing important feedback, not only on your choice of treatment, but also the amount of time you have taken to perform each vital function.
Code Blue III PLUS Family Portable, affordable, interactive, with vital signs monitor included Code Blue III PLUS Adult S300.100 Code Blue III PLUS Five Year S300.105 Code Blue III PLUS Newborn S300.110
Code Blue III Software Use our preprogrammed scenarios, modify them or create your own. Specify condition on this details page Link Palette items to build a linear or branching scenario Changes in condition and care are time stamped and logged Hypoxic model responds to care provider actions The Status panel on the left edge of the GUI window shows vital signs and other details
S300.100 Code Blue III PLUS Adult Ventilations and compressions are measured and logged Now includes monitor to display vital signs Portable Bilateral lung expansion with Affordable realistic chest rise during BVM Interactive Available vital signs monitor Lung Drain Oral and nasal on a realistic airway Spontaneous Breathing Lung Sounds Heart Sounds Blood pressure auscultation and Oxygen saturation placement detection in left arm Intraosseous access with tibia bone Sensors detect depth of Eyes open and close; one pupil is dilated Color change with conditions/ interventions Air-powered bilateral carotid, bilateral femoral, plus left brachial, radial, popliteal and pedal pulse sites. Color and vital signs respond to hypoxic events and interventions IM sites Blood pressure auscultation in left arm ECG Monitoring plus defibrillation, cardioversion and pacing IV training on right arm Oxygen saturation placement detection on the left index finger with real Osat monitor
S300.100 Code Blue III PLUS Adult Features Code Blue III ALS System Use with New CPR standards Oral and nasal on a realistic airway with tongue, vocal cords, trachea and esophagus, use an ET tube or LMA Oral plus suctioning Sensors detect depth of Right main stem Visible gastric inflation with esophageal Color responds to hypoxic events and interventions Accommodates assisted ventilation Bilateral lung expansion with realistic chest rise during ventilation Gastric distension with excessive BVM Ventilations and chest compressions (depth) are measured and logged Conductive skin regions allow for ECG monitoring with real equipment Defibrillate and pace using real devices Automatic bilateral carotid, bilateral femoral, plus left brachial, radial, popliteal and pedal pulse sites using air reservoir Blood pressure auscultation in left arm Korotkoff sounds audible between systolic and diastolic pressures Oxygen saturation placement detection on the left index finger with real Osat monitor Lung Drain Automatic spontaneous breathing using air reservoir Lung and heart sounds Intraosseous access at right tibia IV training on the right arm Intramuscular injection sites in deltoids and quadriceps for placement exercises Choose from Pre-programmed scenarios, or quickly build your own scenarios Activities log for debriefing Resuscitation modeling 15" laptop included Genuine Windows operating system 19 Virtual vital signs monitor USB communications module Communication cable S300.100 Patented; other patents pending Chest compressions include depth measurement Improved airway allows better visualization of vocal cords and easy Conductive skin regions allow for ECG monitoring with real equipment. Also defibrillate, cardiovert, and pace Wireless Communication option Control your simulator wirelessly with the included laptop S300.100.007
S300.105 Code Blue III PLUS Five Year Old Ventilations and compressions are measured and logged Realistic heart and lung sounds Intraosseous access with tibia bone Bilateral lung expansion and automatic spontaneous breathing using air reservoir Oral and nasal on a realistic airway IV training arm Color change with conditions/interventions Oxygen saturation placement detection on the left index finger Automatic Left dorsalis pedis, left popliteal, left radial, and left brachial pulses. + Bilateral femoral pulses, and bilateral carotid pulses; using air reservoir Conductive skin regions allow for ECG monitoring with real equipment. Also defibrillate, cardiovert, and pace Blood pressure auscultation in left arm IM sites Blood pressure auscultation in left arm ECG Monitoring plus defibrillation, cardioversion and pacing Sensors detect depth of Oxygen saturation placement detection on the left index finger with real Osat monitor
S300.105 Code Blue III PLUS Five Year Old Features Code Blue III ALS System Five Year Oral and nasal on a realistic airway with tongue, vocal cords, trachea and esophagus, use an ET tube or LMA Oral plus suctioning Sensors detect depth of Unilateral chest rise with right main stem Visible gastric inflation with esophageal Color responds to hypoxic events and interventions (central cyanosis) Accommodates assisted ventilation Bilateral lung expansion with realistic chest rise Automatic Spontaneous Breathing using air reservoir Gastric distension with excessive BVM Ventilation is measured and logged Conductive skin regions allow for ECG monitoring with real equipment Chest compressions are measured and logged; depth of compressions is measured Automatic left side brachial, pedal, popliteal and radial pulse + bilateral femoral pulse, and bilateral carotid pulse using air reservoir Blood pressure auscultation in left arm Korotkoff sounds audible between systolic and diastolic pressures Realistic heart and lung sounds Oxygen saturation placement detection on the left index finger using real monitor Defibrillate and pace using real devices Realistic ribs Venous access Activities log for debriefing Intraosseous access at right tibia IV training on the right arm Intramuscular injection sites in deltoids and quadriceps for placement exercises Powerful yet intuitive user controller and interface software with pre-programmed scenarios Quickly build your own scenarios Resuscitation modeling 15" laptop included Genuine Windows operating system 19 Virtual vital signs monitor USB communications module Communication cable S300.105 Patented; other patents pending Color and vital signs respond to hypoxic events and interventions (central cyanosis) Defibrillate and pace using real devices Wireless Communication option Control your simulator wirelessly with the included laptop S300.105.007
S300.110 Code Blue III PLUS Newborn Ventilations and compressions are measured and logged Oxygen saturation placement detection on the palm of the right arm Realistic heart and lung sounds Intraosseous access with tibia bone Bilateral lung expansion with realistic chest rise during BVM Umbilical catetherization ECG Oral and nasal on a realistic airway Color change with conditions/interventions (central and peripheral cyanosis) Manual Umbilical, left dorsalis pedis, left popliteal, left radial, and left brachial pulses Conductive skin regions allow for ECG monitoring with real equipment Sensors detect depht of IV training Blood pressure auscultation in left arm Color responds to hypoxic events and interventions (healthy, mild cyanosis, severe cyanosis) Blood pressure auscultation in left arm
S300.110 Code Blue III PLUS Newborn Features Code Blue III Neonatal ALS System Use with New CPR standards Oral and nasal on a realistic airway with tongue, vocal cords, trachea and esophagus, use an ET tube or LMA Oral plus suctioning Sensors detect depth of Unilateral chest rise with right main stem Visible gastric inflation with esophageal Color responds to hypoxic events and interventions (central and peripheral cyanosis) Accommodates assisted ventilation Bilateral lung expansion with realistic chest rise Gastric distension with excessive BVM Ventilation is measured and logged Conductive skin regions allow for ECG monitoring with real equipment Chest compressions are measured and logged Manual left side brachial, pedal, popliteal and radial pulse Umbilical pulse and catheterization Blood pressure auscultation in left arm Korotkoff sounds audible between systolic and diastolic pressures Realistic heart and lung sounds Oxygen saturation placement detection on the palm of the right hand using a real monitor Heart, lungs and ribs Venous access Patent umbilicus Intraosseous access at right tibia IV training on the left arm Intramuscular injection sites in deltoids and quadriceps for placement exercises Powerful yet intuitive user controller and interface software with pre-programmed scenarios Activities log for debriefing Quickly build your own scenarios Resuscitation modeling 15" laptop included Genuine Windows operating system 19 Virtual vital signs monitor USB communications module Communication cable S300.110 Patented; other patents pending Intraosseous infusion and injection system with realistic tibia bones Realistic airway with tongue, vocal cords, trachea and esophagus
Features S300.100 S300.105 S300.110 Oral and nasal on a realistic airway with tongue, vocal cords, trachea and esophagus, use an ET tube or LMA = = = Oral plus suctioning = = = Sensors detect depth of = = = Unilateral chest rise with right main stem = = = Visible gastric inflation with esophageal = = = Color responds to hypoxic events and interventions = = = Accommodates assisted ventilation = = = Bilateral lung expansion with realistic chest rise during BVM = = = Automatic Spontaneous Breathing using air resrvoir = = Realistic heart and lung sounds = = = Gastric distension with excessive BVM = = = Ventilation is measured and logged = = = Conductive skin regions allow for ECG monitoring with real equipment = = = Chest compressions are measured and logged = = = Depth of compressions is measured in cm = = Multiple automatic pulse sites using air reservoir = = Multiple manual pulse sites = Umbilical pulse and catheterization = Blood pressure auscultation in left arm = = = Korotkoff sounds audible between systolic and diastolic pressures = = = Oxygen saturation placement detection = = = Defibrillate and pace using real devices = = Realistic chest cavity = = = Venous access = = = Patent umbilicus = Intraosseous access at right tibia = = = IV training arm = = = Intramuscular injection sites in deltoids and quadriceps for placement exercises = = = Powerful yet intuitive user controller and interface software with preprogrammed scenarios = = = Resuscitation modeling = = = 15" laptop included = = = Genuine Windows operating system = = = 19 Virtual vital signs monitor = = = USB Communications Module with Cable = = = Wireless Communication Option S300.100.007 S300.105.007 Toll Free: USA 800.882.6655 - Worldwide: 305.971.3790 - Fax: 305.667.6085 Email: sales@gaumard.com - www.gaumard.com - Gaumard Scientific, 2013 * Prices when ordered at initial time of purchase MADE IN AMERICA