Implant And Abutment Level Impressions

Similar documents
IOS & The Sirona Connect System Clinician Procedure

Laboratory Designed Abutments (LDA) & Laboratory Designed Abutments For Competitive Systems (LDAC) Quick Reference Guide

The Tapered Implant Slim Surgical Kit. Kit Assembly

LDAC Laboratory Designed Abutments For Competitive Systems. Precision Engineered

LOCATOR Overdenture Implant System

LOCATOR Overdenture Implant System

internal Impression Technique Guide Internal Implant System

open tray technique using the direct pick-up coping

Multi-unit abutment open tray technique using the direct pick-up coping

Restorative Manual. Flexibility By Design

Smile Confidently With DIEM 2. Melissa DelMastro. Immediate Full Arch Rehabilitation

internal impression quick reference guide

closed tray technique using the indirect transfer coping

Providing Clinicians One Solution At A Time With The QNTSK Surgical Kit

Smile Beautifully With Sustainable Aesthetic Solutions

Restorative Manual. Flexibility By Design

Multi-unit abutment closed tray technique using the indirect transfer coping

Straight Octagon Abutment for Tissue Level Implant

closed tray pick-up technique using the snap coping

Scanners From BIOMET 3i. Optimization By Design

FlexLink TiBase. Sustainable Aesthetic Solution

Blue Sky Bio Multi unit Abutments BIO Multi-Units are available for all our Bone Level Implants

verification jig fabrication

IMPRESSION PROCEDURES TRAINING MANUAL

fabricating a custom impression coping using the closed tray technique

4766 Research Dr. San Antonio, TX insightdentalsystems.com

cement-retained single crowns using cementable abutments

Multi-unit abutment bar overdenture

Treatment Options for Restoring Edentulous Jaws using One- and Two-Piece Implants from Implant Direct Int l

Implant Phase Flow Chart

Legacy Prosthetic Catalog

TSV BellaTek Laboratory Solutions. Optimization By Design

Restoring Straumann implants. with Locator abutments.

prosthetic technique manual

Don t Let Life Pass You By Because Of Oral Bone Loss

SwissPlant Prosthetic Catalog. SwissPlant

The Parallel Walled Surgical Kit & Component Assembly

Tapered Implant Surgical Kits & Components Assembly. QNTSK Premium Kit

Hex-Lock Abutment System. Restorative Manual

EXACTECH KNEE. Operative Technique ADDENDUM. Metaphyseal Cones. Surgeon focused. Patient driven. TM

Abutment level impression Ⅰ. Combi abutment/dual abutment Multi units

When It Clicks, It s Seated. You re Certain. The Next-Generation Internal Connection System

ball abutment overdenture: chairside pick-up using existing denture

Multi-unit abutment hybrid or fixed-detachable screw-retained restoration

SS Implant System 2013 PROSTHETIC PROCEDURE

Navigator System Model-Based Surgery Manual

Height* FC width Prep depth RC width 4.0mm+ 4.3mm N/A 6.3mm

REGENERATION BY DESIGN

OD Secure chairside pick-up using existing denture

3. PATIENT POSITIONING & FRACTURE REDUCTION 3 8. DISTAL GUIDED LOCKING FOR PROXIMAL NAIL PROXIMAL LOCKING FOR LONG NAIL 13

screw-retained crown using a PEEK temporary abutment

High-end solution STEP-BY-STEP USER GUIDE

FlexLink TiBase. Sustainable Aesthetic Solution

IMPRESSION-TAKING, BITE REGISTRATION, AND TEMPORARY RESTORATION ON CAMLOG IMPLANTS. a perfect fit

System. Humeral Nail. Surgical Technique

OSS Orthopedic Salvage System Compress Device. Surgical Technique

Product Chart. TOOLS The OSPOL tools fits with all components and both implant diameters. Ø 4,0 mm. Ø 3,35 mm DRILL KIT IMPLANT INSERTER

cement-retained crown using the Laser-Lok Easy Ti temp abutment and PEEK plastic sleeves

LOCATOR F-Tx SEATING AND REMOVAL TOOL PROCEDURES ADDENDUM

RibFix Blu. Thoracic Fixation System

Arcos Interlocking Distal Stem. Surgical Technique Addendum to the Arcos Modular Femoral Revision System

US Implant System 2013 PROSTHETIC PROCEDURE

Introduction of Dentium Implant. Help kit

Ankylos. Acuris conometric concept. Manual and product catalog

Quick start Prosthetics

screw-retained crown using the Laser-Lok Easy Ti temp abutment

OSS Modular Arthrodesis System. Assembly Guide

The LOCATOR concept. Simplicity and versatility for prosthesis fixation

INnate. Surgical Technique Guide. Anatomic Fixation in Your Hands. The INnate Implant

User Manual Complete Prosthetic Kit (CPK)

Multi-Unit Abutment Guide

The AperFix II System

Solid Zirconia Full-Arch Implant Prosthesis (Protocol C All-CAD with Multi-Unit Abutments) BruxZir. FIRST Appointment. The BruxZir

NARROW DIAMETER implant

CoAxial Spray Kit. Simplifying the Application of Platelet-Rich Plasma onto Graft Material. Surgical Technique

Valencia Pedicle Screw Surgical Technique

OT EQUATOR CASTABLE Single Attachment for Overdentures

INSTRUCTIONS FOR THE DENTIST. synocta impression procedure, Screw-retained and Snap-on. Screw-retained (Open tray) Snap-on (Closed tray)

SimpleLine II Surgical / Prosthesis Manual

Laboratory Solutions. Optimization By Design

Astra Tech Implant System. Manual and product catalog OsseoSpeed TX Profile

Restorative Manual. April

INDEX. Pag. 12. Pag. 05. Pag. 06. Pag. 13. Pag. 06. Pag. 14. Pag. 15. Pag. 15. Pag. 15. Pag. 15. Pag. 08. Pag. 16. Pag. 09. Pag.

Longevity Offset and Oblique Liners. Surgical Technique

Natural Tapered Implant Primary Implant Stability Starts With The BIOMET 3i Tapered Implant System

Element-Z Screw-Retained Hybrid

Restorative Manual July 2017

ZMR Over-the-Junction Instruments for Revision Hip Arthroplasty. Surgical Technique IMAGE TO COME

Zimmer NexGen Trabecular Metal Tibial Tray

SURGICAL PROCEDURES FOR ROXOLID IMPLANTS

Implant Mountless Package Handling. Instructions for Use

A complete surgical kit for Premium and Shelta systems

synocta Meso abutment for cement-retained restorations PROSTHETICS Step-by-step instructions

A complete surgical kit for Premium and Shelta systems

EXACTECH SPINE. Operative Technique. Cervical Spacer System. Surgeon focused. Patient driven. TM

HEXAGON Implant System

PRODUCT CATALOG. Since 1985» Simple. Predictable. Profitable.

Integra. DigiFuse Cannulated Intramedullary Fusion System SURGICAL TECHNIQUE

Arcos Modular Femoral Revision System. Broach and Calcar Proximal Bodies Surgical Technique

Transcription:

Implant And Abutment Level Impressions

Implant And Abutment Level Impressions Pick-Up Impression Copings Certain Internal Connection is illustrated below. 1. Select the proper Pick-Up Impression Coping by matching the EP Diameter of the healing abutment and the color of the implant platform. To determine platform diameter, see below. Remove the healing abutment from the implant using a.048 Large Hex Driver (PHD02N or PHD03N). To help prevent accidental swallowing, thread floss through the spinner on the driver. (purple) (blue) (yellow) (green) 3.4mm 4.1mm 5mm 6mm 2. Activate the fingers using the QuickSeat Activator Tool. Place the Pick-Up Impression Coping into the implant, line up the hex and press firmly until feeling a tactile click. Thread the Pick-Up Impression Coping Screw into the implant until finger tight. Tighten the screw using the Large Hex Driver (PHD02N or PHD03N). 3. NOT Radiograph the interface to verify complete seating of the coping on the implant. 4. A custom or stock open impression tray is used for the Pick-Up Impression Technique. Cut a small hole into the tray so that the clinician has access to the screw head. 5. A low, medium or heavy body impression material is recommended for the material in the impression tray. Use light body or injection consistency impression material and syringe impression material around the entire Pick-Up Impression Coping.

6. Load the impression tray and seat it in the mouth. Wipe impression material off the top of the screw so that the screw hex is visible and free of impression material before it sets. Allow the impression material to set per the manufacturer s instructions. 7. After the impression material has set, unscrew and remove the Pick-Up Impression Coping Screw using the.048 Large Hex Driver (PHD02N or PHD03N). Remove the impression from the mouth. 8. Verify that the impression material has completely adapted around the coping and that there is no impression material on the impression coping restorative platform. 9. Immediately replace the healing abutment on the implant using the.048 Large Hex Driver Tip (RASH3N or RASH8N) with a torque device (L-TIRW) and torque to 20Ncm. 10. Place the proper diameter Implant Lab Analog onto the impression coping, engaging the hex. Hold the analog in place while tightening the screw with the Large Hex Driver (PHD02N or PHD03N). Verify that the impression coping is completely seated on the analog. If the clinician is sending the impression to a commercial laboratory to pour it, do not attach the analog. 11. Syringe soft-tissue material around the coping and analog interface. Pour the cast in die stone. Articulate with the opposing cast.

Implant And Abutment Level Impressions Twist Lock Transfer Impression Copings External Connection is illustrated below. 1. Select the proper Twist Lock Impression Coping by matching the EP Diameter of the healing abutment and the color of the implant platform. To determine platform diameter, see below. Remove the healing abutment from the implant using a.048 Large Hex Driver (PHD02N or PHD03N). To help prevent accidental swallowing, thread floss through the spinner on the driver. (purple) (blue) (yellow) (green) 3.4mm 4.1mm 5mm 6mm 2. Place the Twist Lock Impression Coping on the implant and engage the hex. Thread the Twist Lock Impression Coping Screw into the implant until finger tight. Tighten the screw using an Impression Coping Driver (ICD00). 3. Radiograph the interface to verify complete seating of the coping on the implant. NOT 4. A custom or stock impression tray is used for the Twist Lock Transfer Impression technique. Try in the tray to verify that there is no contact with the coping. 5. A low, medium or heavy body impression material is recommended for the material in the impression tray. Use light body or injection consistency impression material around the entire Twist Lock Impression Coping. 6. Load the impression tray and seat it in the mouth. Allow the impression material to set per the manufacturer s instructions.

7. After the impression material has set, remove the impression from the mouth. The Twist Lock Impression Coping will remain on the implant. Verify that the impression material completely adapted around the coping. 8. Remove the Twist Lock Impression Coping from the implant using the Impression Coping Driver (ICD00). 9. Immediately replace the healing abutment on the implant using the.048 Large Hex Driver Tip (RASH3N or RASH8N) with a torque device (L-TIRW) and torque to 20Ncm. 10. Place the proper diameter Implant Lab Analog into the impression coping, engaging the hex. Hold the components together while finger tightening the screw. Verify that the impression coping is completely seated on the analog. 11. Re-index the impression coping/analog assembly into the impression using firm pressure to its full depth. Slightly rotate the coping/analog clockwise until feeling anti-rotational resistance. 12. Syringe a soft-tissue material around the coping and analog interface. Pour the cast in die stone. Articulate with the opposing cast.

Want More Restorative Options? www.biomet3i.com For More Information, Please Contact Your Local BIOMET 3i Sales Representative. Global Headquarters 4555 Riverside Drive Palm Beach Gardens, FL 33410 1-800-342-5454 Outside the U.S.: +1-561-776-6700 Fax: +1-561-776-1272 www.biomet3i.com EC REP BIOMET 3i Dental Iberica S.L. WTC Almeda Park, Ed. 1, Planta 1ª Pl. de la Pau, s/n 08940, Cornellà de Llobregat (Barcelona) Spain Phone: +34-93-470-55-00 Fax: +34-93-371-78-49 Join Us Follow Us Watch Us Download It Certain, EP and QuickSeat are registered trademarks and Providing Solutions - One Patient At A Time and Twist Lock are trademarks of BIOMET 3i LLC. 2014 BIOMET 3i LLC. All trademarks herein are the property of BIOMET 3i LLC unless otherwise indicated. This material is intended for clinicians only and is NOT intended for patient distribution. This material is not to be redistributed, duplicated or disclosed without the express written consent of BIOMET 3i. For additional product information, including indications, contraindications, warnings, precautions and potential adverse effects, see the product package insert and the BIOMET 3i Website. For instructions go to: www.ifu.biomet3i.com. INST1123 REV A 11/14