ABR Screener Excellence in Newborn Hearing Screening

Similar documents
ABR Screener Excellence in Newborn Hearing Screening

ERO SCAN. OAE Test System. Screener. Diagnostic. with 4 frequency DPOAE testing Protocols

by Maico Diagnostics

OAE Test System. by Maico Diagnostics ERO SCAN. EroScan Pictured. OAE Hearing Screener DPOAE/TEOAE Test Systems.

Handheld OAE-Tympanometry Combination System

ERO SCAN. Otoacoustic Emission Testing

OAE Test System. Screener PLUS. Diagnostic PLUS. with 4 frequency DPOAE testing Protocols

Titan power The best just got better. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device.

GRASON-STADLER HEARING ASSESSMENT SYSTEMS

Titan power The best just got better. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device

Titan power The best just got better. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device

Science made smarter. Titan. Advanced made flexible. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device

GSI AUDIOscreener OAE AND ABR HEARING SCREENING

the truly automated all-in-one hearing screener

OtoRead Portable OAE. More Time for Care. Optimized for Accuracy and Ease of use

General Catalogue. Product Line for Hearing Screening & Diagnostics

General Catalogue. Hearing Screening & Diagnostics

the truly automated all-in-one hearing screener Only the Echo-Screen Hearing Screener combines

The Eclipse High quality evoked potentials at your command. AEP, ASSR, & OAE testing on one dedicated platform

The Most Outstanding Features & Benefits of Today s Auditory Evoked Potentials (AEP) Systems

Neuro-Audio Version 2010

General Catalogue. Hearing Screening & Diagnostics

General Catalogue. Product Line for Hearing Screening & Diagnostics

ABR PTA ASSR Multi-ASSR OAE TEOAE DPOAE SOAE VEMP ECochG MLR P300

Reliable, flexible & precise

General Catalogue. Product Line for Hearing Screening & Diagnostics

The Eclipse Designed to meet your every need. AEP, ASSR, VEMP & OAE testing on one dedicated platform

MB11 Classic - Operating Instructions

On the following pages you ll find a few more specific features to consider in evaluating OAE equipment.

Advanced. NEW! Four times faster DPOAE: concurrent measurement of both ears while recording two DPs simultaneously in each ear!

GSI TYMPSTAR PRO CLINICAL MIDDLE-EAR ANALYZER. Setting The Clinical Standard

ECHOLAB. Screening and Clinical Modality. User Programmable Protocols. Otoacoustic Emissions System TEOAE - DPOAE - ABR - AABR

ER75 Electro-Acoustic Ear Simulator. Operating Manual

AC40. The true clinical. hybrid

UNITY 2. a state-of-the-art audiological integrated diagnostic and fitting system

Eclipse Evoked Potential System. 10 reasons to choose

BERA The HOMOTH ABR / BERA- module is a real time brainstem audiometer. It is developed considering the latest knowledge of the ENT research.

AUDIOLAB Two channel clinical audiometer. Tonal Audiometry Vocal Audiometry MASKING SISI ABLB Decay Test BEKESY

Early Hearing Detection & Intervention Programs, Pediatricians, Audiologists & School Nurses use AuDX Screeners

Protocol for Fast, Efficient Audiogram Prediction using Electrophysiology. Sponsored By

Affinity 2.0 integrated fitting solution. Audiometry, REM, HIT, and Visible Speech Mapping

AD629 The true hybrid

Equinox 2.0 PC-based audiometer. Not just an audiometer - A full counseling and reporting solution

TWO CHANNEL CLINICAL AUDIOMETER AUDIOSTAR PRO

Oscilla - excellence since 1960

myaudiometer. It s familiar, and it s so much

EPIC-PLUS System for auditory evoked potentials and neuro-otology. PEA - VEMPs ASSR - E-ABR FACIAL NERVE

Sleep diagnostics systems

MA 25 Operating Manual

ADHEAR The new bone-conduction hearing aid innovation

LEARNING TO USE YOUR FIRST HEARING AID

HIGH DEFINITION HEARING DEVICE. User Guide. ihear Clearly, Invisible

A full product range for your every need. World leading diagnostic solutions

(OAEs) for. Steven D. Smith, Au.D.

III. Comprehensive. Efficient. Auditory EP Testing

The registration testing for audiometric device in CFDA

GSI AUDIOSTAR PRO CLINICAL TWO-CHANNEL AUDIOMETER

Hearing Evaluation: Diagnostic Approach

Operating Instructions MA 25

The future of fitting

The following describes general use of ELIOS device

FONIX FP35. Ease and Accuracy with the FP35 Touch Hearing Aid Analyzer! Visible Speech

The true clinical hybrid audiometer. Interacoustics. Clinical Audiometer AC40. Stand alone & PC-based audiometry in one box.

Fitting System Instructions for Use

AUTOMATED AUDITORY BRAINSTEM RESPONSE INFORMATION AND GUIDELINES FOR SCREENING HEARING IN BABIES

Newborn Screening and Middle Ear Problems

! Caution (continued)

AT235/AT235h Middle Ear Analyzers. Diagnostic & clinical tympanometry with basic audiometry.

Provisional guidelines for using Auditory Steady State Responses (ASSR) in babies. July 2009

GSI 61 CLINICAL TWO-CHANNEL AUDIOMETER

AURICAL Plus with DSL v. 5.0b Quick Guide. Doc no /04

Note: This document describes normal operational functionality. It does not include maintenance and troubleshooting procedures.

Dear HighQ Check System Owner :

QUICK START GUIDE SENTIERO DESKTOP OAE AND TYMP SCREENER (BLUE HOUSING)

MADSEN AccuScreen OAE & ABR Screener

Newborn Screening Free health checks for your baby. Newborn. Hearing Screening. Referral to Audiologist

Tele-audiology. Deviceware. Integration with Resonance Portable Diagnostic Devices. White Paper (v1.1)

Blood glucose monitor. MediTouch 2

The true clinical hybrid audiometer Stand alone & PC-based audiometry in one box. Interacoustics. Clinical Audiometer AC40.

James W. Hall III, Ph.D.

INSTALLATION MANUAL. VIDEO Camera, Probe and Lightsource OTOSCOPES.

AT235 Middle Ear Analyzer. Diagnostic & clinical tympanometry with basic audiometry

Contents. Foreword by James W. Hall III, PhD and Virginia Ramachandran, Aud, Series Editors Preface

experiences that matter

Hearing Solutions Catalog Winter Supplement January 2009

CE-Chirp. Making ABR fast, accurate and clear! Stimulus Family

Bio-logic AuDX PRO FLEX Screening tympanometry and audiometry Quick start guide

For more information visit or contact hearx:

Two Modified IEC Ear Simulators for Extended Dynamic Range

Updates to NHSP guidance for post-screening diagnostic testing Update 1: August 2015 Author: BSA Electrophysiology Special Interest Group (BSA EP SIG)

The Level Specific CE-Chirp

Identification. Eartips. Battery Door. 2-Position Switch. Eartip. Removal Cord. Flexible Neck Cord Protective Case. Filter Tool and Extra ACCU Filters

Unlock. your potential. Otometrics Madsen A450 the audiometer that works for you N O A H P M M R E P O R T I N G H I T C O U N S E L I N G

Spirometry Sleep diagnosis Audiometry

Equinox 2.0. PC-based audiometer. Time saving solutions. Interacoustics. leading diagnostic solutions

Transcription:

MB 11 Patented CE-Chirp stimulus reduces test times Virtually no cost or low cost supplies reduce program costs Classic and BERAphone hardware models offer choices to meet your program needs ABR Screener Excellence in Newborn Hearing Screening

Re-usable electrodes and integrated earphone reduce operating costs significantly Eco-friendly technology reduces medical waste Baby-friendly - no discomfort caused by pulling adhesive disposables off of baby s skin The Only Automatic ABR Screener without Adhesive Electrodes Apply electrode gel at the 3 electrode sites on the baby s head Place a drop of electrode gel on the integrated electrodes Position the BERAphone ear cushion around the baby s ear, resting the electrodes on the prepared sites Why Screen with Automatic ABR? The auditory brainstem response (ABR) reflects the function of the entire auditory pathway up to the brainstem. While both ABR and the alternate screening technology of otoacoustic emissions (OAE) detect cochlear hearing loss, only ABR detects auditory neuropathy.

Fast Test Times Fast rate ABR technology with patented CE-Chirp stimulus leads to faster test times Compatible with NHS Databases Comply with reporting requirements (HiTrack, OZ esp, Auris, California Data Management Service) USB-Powered Hardware Combine MB 11 with a laptop PC to test on battery power; avoid rebooting as you move the system Custom Cart Package (optional) Easy transport from room to room; locked compartment for laptop security and storage for supplies User-Friendly Software Simple user interface enhances ease of training. Traffic light display for electrode contact and test quality provides easy to understand feedback to screeners. Patented chirp stimulus and advanced response detection algorithm allow fast test times. Oz and HiTrack compatible export functions available.

MB 11 Classic - Advanced Technology, Familiar Technique Test both ears simultaneously to save time Familiar hardware and disposables streamline training of screeners Choose between EarCups or in-the-ear tips based on your preference and budget Combine Classic and BERAphone hardware on one system for ultimate flexibility MAICO s Long History of Hearing Instrument Manufacturing The Medical Acoustic Instrument Company (later shortened to MAICO) was founded in 1937 in Minneapolis, MN. MAICO designed and produced the first hearing test instrument with a zero reference level, coining the term audiometer. For the first time it was possible to accurately measure hearing loss. Since then, MAICO has continued to design and manufacture screening and diagnostic test instruments for the hearing healthcare industry. The MB 11 BERAphone and Classic evolved over 12 years of research and development. They are intended to generate auditory brainstem response (ABR)-based measurements for newborn hearing screening, providing a Pass/Refer result. Use of the MB 11 Screener does not require special technical skills or interpretation of results.

Big Savings with the MB 11 How much money can YOUR newborn hearing screening program save by using a MAICO MB 11 BERAphone or Classic? Let s See! Even if Popular Brand X new system price is significantly discounted, the major savings using MB 11 is in the cost of disposables over the life of the system Think your current system is too new for replacement? Think again!

MB 11 - Specifications Technical Data MB 11 BERAphone Standards: IEC 601-1, IEC 645-3 Stimulus type: CE-Chirp Stimulus Stimulus rate: 93/s Stimulus intensity: 35 db nhl Sample rate: 16 khz EEG filter: 125 Hz 1.25 khz Quality control: Integrated LED on BERAphone and display in software with signal quality or with EEG display Operating conditions: + 59 to +95 F, (+15 to +35 C); Maximum humidity 75% Storage conditions: +41 to +122 F, (+5 to +50 C); Maximum humidity 90% Speaker: BERAphone : integrated, dynamic wideband speaker (8Ω) Electrodes: BERAphone : reusable, stainless steel electrodes with gel protectors. Preamplifier: Integrated, 87 db amplification (23,000 x) BERAphone weight: 10.59 oz, (300 g) USB box weight: 5.83 oz, (165 g) USB box dimensions: 4.73 x 3.55 x 1.19 in, (12 x 9 x 3 cm) Power supply: via USB port of computer Power consumption: max 400 ma STANDARD COMPO- NENTS - MB 11 BERAphone BERAphone unit Additional set of stainless steel electrodes with gel protectors USB connection cable Carrying bag (not provided with cart option) Electrode gel (2 bottles) Disinfectant wipes (1 tub) MB-11 software on USB Flash Drive or CD Operation Manual Quick Guide MB 11 Classic Standards: IEC 60601-1, IEC 60645-3 Stimulus type: CE-Chirp Stimulus Stimulus rate: 93/s Stimulus Intensity: 35 db nhl Sample rate: 16 khz Quality control: Integrated LED on Amplifier hardware and display in software with signal quality or with EEG display Operation conditions: + 59 to +95 F, (+15 to +35 C); Maximum humidity 75% Storage conditions: +41 to +122 F, (+5 to +50 C); Maximum humidity 90% Transducer: ER3A insert earphones Electrodes: Disposable snap Preamplifier: Integrated, 87 db amplification (23,000 x) USB box weight: 5.83 oz, (165g) USB box dimensions: 4.73 x 3.55 x 1.19 in, (12 x 9 x 3 cm) Power supply: Via USB port of computer Power consumption: Max 400 ma STANDARD COMPONENTS - MB 11 Classic MB 11 Classic with preamplifier and USB box USB cable Set of 3 pinch clip electrode leads Ear-tone ER3a insert earphones with either EarCup adapters and tubes or with the infant eartip adapters and tubes Sanibel EarCup couplers, snap electrodes and electrode skin prep pads (1 box of 20 sets) OR Disposable eartips (3-5 mm and 4-7 mm sizes) and snap electrodes NuPrep skin preparation gel (1 tube) MB 11 software on USB flash drive Operating Manual Quick Guide Cradle for BERAphone

Testimonials Infant Hearing Screening Specialists (IHSS) provide newborn hearing screening services for 79 hospitals across the state of California. In 2009, IHSS began using the Maico MB 11 BERAphone auditory brainstem response (ABR) screening system in many of our hospitals, replacing the traditional ABR screening systems that use disposable electrodes and ear couplers. The BERAphone features reusable stainless steel electrodes and a reusable ear cushion avoiding the expense of disposables and offering an eco-friendly screening ABR option, reducing the amount of waste. A small amount of water-soluble electrode gel is used to prepare the baby s skin at the electrode sites and a disinfectant wipe is used to disinfect the device after use. Considering the cost of these consumables, each screening using the BERAphone costs approximately $0.25 for supplies. This is in contrast to the $1.00 -$13.00 per screening that IHSS spent using legacy OAE and ABR screening devices. In 2014, IHSS screened 140,762 newborns using the BERAphone for a cost savings of $850,000 compared to what it would have cost using disposables. In 2014, the average refer rate across the hospitals in which the BERAphone was used was 3.55% with a range of 1.0-6.9%. This refer rate was comparable to the refer rates achieved in other hospitals that have not yet transitioned to the BERAphone. The transition from a traditional ABR screener to the BERAphone presented some early challenges for screening staff. The BERAphone must be hand-held over the baby s ear to maintain electrode contact to the scalp during the screening. The skin preparation procedure was different from the other devices they had been using. Changing the behavior of individuals who had become comfortable with a device that used disposables was not easy for everyone. There was a period of resistance and frustration from some of the screeners as they worked to master the new procedure and techniques needed to use the BERAphone. Using the Maico MB 11 BERAphone, IHSS is saving money and reducing waste sent to landfills, while continuing to provide high quality hearing screening outcomes for our partner hospitals. IHSS screeners have adapted to the BERAphone and now prefer it to disposable-based ABR devices. Their experience with the BERAphone is that testing is faster than with traditional systems. Additionally, there is less discomfort for the baby since there are no adhesive disposables to remove after the screening which parents greatly appreciate. IHSS now uses the Maico MB 11 BERAphone as the ABR screening device of choice in 68 of its hospitals and is working toward replacing all the remaining traditional systems currently in use.

Testimonials Our nurses have been performing ABR hearing screening tests for many years at our hospital. Since our equipment was old and needed to be replaced, I decided to try the Maico MB 11 Classic that I had seen at a recent nursing conference. It took our nurses a few days to transition to some differences in the hardware and software. Very soon, however, the fast speed of the screenings convinced everyone that using the MB 11 Classic was a time-saver compared to screening with our old device. Plus my Director of Maternal & Child Health is thrilled that the MB 11 EarCups and electrodes cost so much less than the other manufacturer s disposables. I am so happy that we tried the Maico MB 11 Classic. We found an ABR hearing screener that is faster to use and more economical for our program. - Newborn Hearing Screening Program Manager I have been doing hearing screens for over 10 years. When my program administrator told me we were going to try out a different device, I was not happy about having to learn a new system. But now that I have been using the Maico MB 11 BERAphone for a few weeks, I have to admit that I am blown away by the speed of the screenings. It takes so much less time to complete a refer test and the passes are also generally much faster than with the previous equipment. I now have more time to spend with my patients. I m happy that I tried something new. - Staff nurse newborn nursery I received a brochure in the mail regarding the Maico MB 11 ABR newborn hearing screener. The Nurse Manager of our Newborn Nursery had recently contacted me about replacing our current hearing screening device, which was 7 years old. Since the brochure said there was a big potential for cost-savings on disposables using the Maico screener, I suggested the Nurse Manager give it a try. Her nurses trialed the MB 11 Classic. The nurses transitioned easily to using the Classic since the screening procedure was very similar to the device they were currently using. They really liked the device because the tests are so much faster to perform. We purchased the Classic and now the hospital is saving approximately 30% in disposable costs, which was a major goal from my perspective. - Hospital Purchasing Director MAICO Diagnostics 10393 West 70th St Tel.: 888.941.4201 e-mail: info@maico-diagnostics.com Eden Prairie, MN 55344 Fax: 952.903.4100 Web: www.maico-diagnostics.com 1-2015