Effects of Capital Collar Enhanced on Head-Cervical Movements in Comparison with Miami J Advanced and Aspen Vista TX Collars

Similar documents
Journal of Rehabilitation Sciences and Research. Evaluation of the Efficiency of Minerva Collar on Cervical Spine Motions

Development of a Novel Biofedelic Skull-Neck- Thorax Model Capable of Quantifying Motions of aged Cervical Spine

Accuracy and validity of Kinetisense joint measures for cardinal movements, compared to current experimental and clinical gold standards.

Effects of Altered Surface Inclinations on Knee Kinematics During Drop Landing

Discover the leading global community of spine surgeons

Obesity is associated with reduced joint range of motion (Park, 2010), which has been partially

subluxation: a radiographic comparison

Discrepancies in Knee Joint Moments Using Common Anatomical Frames Defined by Different Palpable Landmarks

BIOMECHANICAL ANALYSIS OF THE DEADLIFT DURING THE 1999 SPECIAL OLYMPICS WORLD GAMES

IN VIVO CERVICAL SPINE KINEMATICS, ARTHROKINEMATICS AND DISC LOADING IN ASYMPTOMATIC CONTROL SUBJECTS AND ANTERIOR FUSION PATIENTS.

Quality of Life. Quality of Motion.

Gender Based Influences on Seated Postural Responses

EVALUATION OF THE ANKLE ROLL GUARD S EFFECTIVENESS TO IMPROVE ITS CLINICAL BENEFIT PROGRESS REPORT. Prepared By:

Kinematics of Lateral Transfers: A Pilot Study. Sharon Sonenblum, ScM Thursday, August 4 th, 2005

Evaluating the accuracy of markerless body tracking for digital ergonomic assessment using consumer electronics

A marker set for measuring the kinematics of the lumbar spine and thoracic spine during running : a technical note

What is Kinesiology? Basic Biomechanics. Mechanics

Life Changing Spinal Innovation

ASSESSMENT OF LUMBAR SPINE POSTURE DURING SITTING ON A DYNAMIC SITTING DEVICE (FLEXCHAIR )

Abstract. A novel device to improve sitting posture. Hoda Dalimi (1) Ali Ghorbani (2) Anoushirvan Kezam nejad (3) Mohammad Hossein Alizadeh (4)

FUSE TECHNICAL REPORT

Using Biomechanical Principles in the Management of Complex Postural Deviations in Sitting

A Computational Model of Annulus Fiber Deformation in Cervical Discs During In Vivo Dynamic Flexion\Extension, Rotation and Lateral Bending

A New Orthosis for Fixation of the Cervical Spine Fronto- Occipito-Zygomatic Orthosis

A wheelchair is a body orthosis on wheels. Understanding basic principles of seating. Seating REQUIREMENTS OF SEATING

TAKE-OFF CHARACTERISTICS OF DOUBLE BACK SOMERSAULTS ON THE FLOOR

CAN PARAMETERS OF THE HELICAL AXIS BE MEASURED RELIABLY DURING ACTIVE CERVICAL MOVEMENTS?

Selected Topics: Prehospital Care

Bull AMJ, McGregor AH. Measuring spinal motion in rowers: the use of an electromagnetic. device. Clin. Biomech. 15, (2000),

Lecture 2. Statics & Dynamics of Rigid Bodies: Human body 30 August 2018

erhem Thoracal spine section Elastic shoulder brace with support bracing Application:

Analysis of Upper Extremity Motion in Children After Axillary Burn Scar Contracture Release

DIAGNOSTIC VIDEOFLUOROSCOPY IMPRESSIONS and BIOMECHANICS REPORT

Coordination indices between lifting kinematics and kinetics

Noble Hinge Technology CHANGING THE FOUNDATION OF SPINAL BRACING

National Exams November hours duration

3/10/17 Spinal a Injury 1

Biomechanics and Its Application to Seating

Life Changing Spinal Innovation. Product Catalog. Upper & Lower Spinal Orthotics

P04-24 ID239 MECHANISM OF LANDING STRATERGY DURING STEP AEROBICS WITH DIFFERENT BENCH HEIGHTS AND LOADS

My Fulbright Experiences at Rosario University and in Colombia

Subaxial Cervical Spine Trauma Dr Hesarikia BUMS

Three-Dimensional Motion Analysis of Lumbopelvic Rhythm During Trunk Extension

Muscle Activation in strength training exercises with and without using the clip-on device Gripper

Andrew J Murphy

Chapter 7. Inter-rater reliability of a video-analysis method measuring low-back load in a field situation.

Spine, October 1, 2003; 28(19): Eythor Kristjansson, Gunnar Leivseth, Paul Brinckmann, Wolfgang Frobin

Joint Range of Motion Assessment Techniques. Presentation Created by Ken Baldwin, M.Ed Copyright

SpineScan Instructions for Use

4/19/2017. Prehospital Spinal Care: Then. Prehospital Spinal Care: Then. Prehospital Spinal Care: Then. Prehospital Spinal Care: Then. Why Immobilize?

Bracing for Scoliosis

NECK & SHOULDER. mediroyal.se

Maximal isokinetic and isometric muscle strength of major muscle groups related to age, body weight, height, and sex in 178 healthy subjects

Analysis of the functional biomechanics of different chair types during esports activity

Cervical Spine Injury Guidelines

OMT Without An OMT Table Workshop. Dennis Dowling, DO FAAO Ann Habenicht, DO FAAO FACOFP

Evaluating Sagittal Spinal Posture During Functional Tasks:

SPINAL IMMOBILIZATION

The Effects of Carpal Tunnel Syndrome on the Kinematics of Reach-to-Pinch Function

Motion Capture Assessment of Athletic Injury Risk

Cruciform anterior spinal hyperextension (CASH) brace with round anterior chest pads.

Lab Workbook. ANATOMY Manual Muscle Testing Lower Trapezius Patient: prone

Chia-Wei Lin, Fong-Chin Su Institute of Biomedical Engineering, National Cheng Kung University Cheng-Feng Lin Department of Physical Therapy,

Helmet fit and cervical spine motion in collegiate men s lacrosse athletes secured to a spine board.

Heidi Lako-Adamson, MD, NRP, FAEMS FM Ambulance and Sanford EMS Education Medical Director

Life Changing Spinal Innovation. Product Catalog. Upper & Lower Spinal Orthotics

***Note: Figures may be missing for this format of the document ***Note: Footnotes and endnotes indicated with brackets

An Innovative Measurement in Musculoskeletal Rehabilitation Using 3D Motion Analysis

Selected Topics: Prehospital Care

Kinematic Analysis of Lumbar Spine Undergoing Extension and Dynamic Neural Foramina Cross Section Measurement

Structure and Function of the Bones and Joints of the Shoulder Girdle

University of Groningen

Are scoop stretchers suitable for use on spine-injured patients?

Cervical Spine Alignment During On-Field Management of Potential Catastrophic Spine Injuries

Load-Displacement Characteristics of the Cervical Spine During Shear Loading

Validity and reliability of sincerity test for dynamic trunk motions

Computing realistic loads in the lumbar spine by using the AnyBody musculoskeletal model

Spinal Dynamics I: The Axio-atlanto-occipital Assemblage

Shenandoah Co. Fire & Rescue. Injuries to. and Spine. December EMS Training Bill Streett Training Section Chief

Investigation of Human Whole Body Motion Using a Three-Dimensional Neuromusculoskeletal Model

CERVICAL STRAIN AND SPRAIN

Effects of Attachment Position and Shoulder Orientation during Calibration on the Accuracy. of the Acromial Tracker

The effectiveness of extrication collars tested during the execution of spine-board transfer techniques

CERVICAL STRAIN AND SPRAIN (Whiplash)

Specializing in Mechanical Testing for Medical Devices. Office:

Raymond Wiegand, D.C. Spine Rehabilitation Institute of Missouri

Summary Chart 1 2 months

Biomechanics of Two Reconstruction Techniques for Elbow Ulnar Collateral Ligament Insufficiency

Fractures of the Thoracic and Lumbar Spine

Biomechanical Characterization of a New, Noninvasive Model of Anterior Cruciate Ligament Rupture in the Rat

Spinal Alignment and corrective exercise: The importance of posture in the frailer older adult.

Using Biomechanical Principles in the Management of Complex Postural Deviations in Sitting

Comparing Dominant and Non-Dominant Torque and Work using Biodex 3 Isokinetic Protocol for Knee Flexors and Extensors INTRODUCTION PURPOSE METHODS

ISOLATED LUMBAR EXTENSION RESISTANCE EXERCISE REDUCES LUMBAR KINEMATIC VARIABILITY DURING GAIT IN CHRONIC LOW BACK PAIN PARTICIPANTS

Mechanism of Injury, Trauma, Subluxation and Instability Outline

Validity of Data Extraction Techniques on the Kinetic Communicator (KinCom) Isokinetic Device

Radiology of Cervical Spine Trauma. Cervical Spine Trauma. Imaging Standards. Canadian C. Spine Rule 11/28/2016

Supplemental Digital Content 1

EMS Update Spinal Motion Restriction Training

Transcription:

DeRoyal Industries, Inc. 2013 Effects of Capital Collar Enhanced on Head-Cervical Movements in Comparison with Miami J Advanced and Aspen Vista TX Collars Biomechanics/Sports Medicine Laboratory Department of Exercise, Sport and Leisure Studies The University of Tennessee Knoxville, TN, USA

A research report prepared for DeRoyal Industries, Inc. By Songning Zhang, PhD Jacob Gardner, MS Xuan Liu, BS Contact Songning Zhang, PhD and FACSM Director, Biomechanics/Sports Medicine Laboratory Department of Kinesiology, Recreation, & Sport Studies The University of Tennessee Knoxville, TN, USA Phone: (865) 974-4716 FAX: (865) 974-8981 Email: szhang@utk.edu

EXECUTIVE SUMMARY The main objective for the research project was to examine the kinematic restrictive effects of a newly designed adjustable cervical collar (Capital Collar Enhanced (CCE), DeRoyal Industries, Inc.) on the head-cervical 3D movements compared to those of two other similar cervical collars, Aspen Vista TX and Miami J Advanced. A total of 19 subjects (9 females and 10 males) participated in the study. During testing, each subject performed 5 movement trials to the beat of a metronome set at 50 beats per minute in each of the 12 testing conditions, which is the combination of 4 collar conditions, no collar and 3 cervical collars, and 3 movements, flexion-extension, left-right lateral flexion and left-right axial rotation. Threedimensional kinematic data of the head, cervical collar and trunk were captured using a 9- camera Vicon motion capture system at 240 Hz. The statistical comparisons showed that the maximum extension angle was reduced in the CCE compared to Vista TX (p = 0.011). In addition, the total ROM was reduced in both Advanced (p = 0.043) and CCE (p = 0.042) compared to Vista TX. The maximum left flexion angle was also decreased in Advanced (p = 0.002) and CCE (p < 0.001) compared to Vista TX. Similarly, the maximum right flexion angle and total ROM were also decreased in Advanced (p < 0.001 & p < 0.001) and CCE (p < 0.001 & p < 0.001) compared to Vista TX. The maximum left and right axial rotation angles and total ROM were all reduced significantly in the three collars (p < 0.001) compared to no collar. In addition, the maximum right rotation and total axial rotation ROM were reduced in CCE (p = 0.005 & p = 0.005) compared to Advanced. The peak left axial rotation angle was decreased in CCE (p = 0.031) compared to Vista TX. In conclusion, the study results demonstrated that both Capital Collar Enhanced and Miami J Advanced cervical collars had greater effects on restricting head-neck movements in flexion-extension and lateral flexion. However, the Capital Collar Enhanced showed greater restriction on axial rotations of head-neck than Miami J Advanced and Aspen Vista TX collars. No apparent effects of the adjustable support structure were observed on the head distractions for all three tested cervical collars.

INTRODUCTION Cervical collars are often prescribed to patients who have sustained a cervical spine injury. The objectives for spinal orthoses applications include correction of spinal deformity and malalignment, intervertebral segmental immobilization, regional stabilization, maintaining a specific spinal posture, and protection from damaging stresses during the healing process (White & Panjabi, 1990). The cervical spine enjoys the greatest range of motion (ROM) of the entire spine. Cervical orthoses are often prescribed to be used in both extrication stabilization of trauma patients and as a treatment option of injuries to the cervical spine (Richter, et al., 2001). There are three types of conventional cervical braces with variation within each category, including soft cervical collar, upright poster-brace with padded mandibular and occipital supports, and cervicothoracic orthoses with support similar to the poster brace but further reinforced by rigid metal or plastic connections (Johnson, Hart, Simmons, Ramsby, & Southwick, 1977; White & Panjabi, 1990). More recently, adjustable cervical collars have emerged in the market and offer better fit and superior supports and restrictions of head-neck motions. Therefore, the objective for the research project was to examine the kinematic restrictive effects of a newly designed and adjustable cervical collar (Capital Collar Enhanced, DeRoyal Industries, Inc.) on the head-cervical three-dimensional (3D) movements compared to those of two other similar cervical collars, Aspen Vista TX and Miami J Advanced. METHODS Participants A total of twenty subjects were recruited and participated in the study. Due to technical difficulties, one subject was excluded in the final analyses. Therefore, 19 healthy female (N=9, Age: 28.4 ± 6.8 years, Height: 1.66 ± 0.02 m, Mass: 62.5 ± 13.0 kg, BMI: 22.6 ± 4.3 kg/m 2 ) and

male (N=10, Age: 27.1 ± 3.9 years, Height: 1.78 ± 0.08 m, Mass: 74.7 ± 13.9 kg, BMI: 23.6 ± 3.3 kg/m 2 ) subjects between the ages of 18 and 40 were included for the analyses. Subjects were free of injury at the time of testing and had no major past head, neck, or trunk injuries or pathologies. Prior to participation, all subjects read and signed the study s informed consent which was approved by the University of Tennessee Institutional Review Board. Instrumentation 3D High-speed Video System: A nine-camera motion capture system (240 Hz, Vicon Motion Analysis Inc., UK) was used to obtain the three-dimensional (3D) kinematics during the test. Reflective anatomical markers were placed on the greater trochanters, acromion processes, and ear canals. A cluster of four reflective markers affixed to a semi-rigid thermoplastic shell was placed on the trunk to track the trunk motions. Four tracking markers were placed on a headband affixed around the head to track head motions (Figure 1). Eight additional markers were placed on the cervical collars to identify and track the collar movements during the dynamic testing. Separate static trials were recorded for each of the four collar conditions. Customized testing chair: Subjects were asked to sit in a customized testing chair equipped with two shoulder straps, a waist strap and a lap strap. The trunk and waist of subjects was stabilized in the chair by the respective straps while the neck and head were free from any restriction. Visual3D: Visual3D (C-Motion, Inc.) 3D biomechanical analysis software suite was used to compute 3D kinematic variables. The 3D marker trajectories were filtered at 4 Hz using a low-pass zero lag digital Butterworth filter. Customized software: Customized software (VB_V3D and VB_Tables, Microsoft Visual BASIC, 6.0) was used to compute and determine critical events of the computed variables from the Visual3D outputs, and to organize the data for reports and statistical analyses. Cervical collars (Figure 2): Adjustable cervical collars, Aspen Vista TX Collar (Aspen Medical Products, Irvine, CA), Miami J Advanced (Ossur Americas, Foothill Ranch, CA), and

Capital Collar Enhanced (CCE, DeRoyal Industries, Inc., Powell, TN) were applied to the neck and trunk regions during the experimental conditions according to the manufacturer s instructions. Figure 1. The 3D models of the head-neck, trunk and cervical collar (invisible from the view). A) B) C) Figure 2. Cervical collars tested in this study: A) Aspen Vista TX Collar, B) Miami J Advanced, and C) DeRoyal Capital Collar Enhanced (CCE).

Experimental Protocol After reading and signing the informed consent form, subjects were instructed to lie in a supine position on a treatment table where the cervical collars were applied as per the manufacturer s instructions. Once the collar was applied, the head height was adjusted for each collar so that the subject s head remained in a neutral position while sitting/standing. There were four collar conditions which were no collar (control), Vista TX, Advanced, and CCE, and three movement conditions of flexion/extension, left and right lateral flexion and left/right rotations for a total of 12 testing conditions. Following the collar application, reflective anatomical and tracking markers were placed on the subject s body and on the cervical collars as described above. The markers were recorded using 3D motion analysis software (Vicon Nexus), in order to quantify the three motions performed by the subjects. Each subject was strapped into the customized testing chair that restrained trunk and lower body movements, but allowed freedom of movement in the head and neck. A static trial was recorded for each subject and for each collar condition. During testing, each subject performed five movement trials to the beat of a metronome set at 50 beats per minute in each of the 12 testing conditions. The metronome was used to standardize the speed of the head-neck rotational movements across subjects to reduce potential bias introduced by differences in angular movement speeds. Each subject was instructed to reach the end of the full range of motion on the beep of the metronome. For example, during the flexion and extension in the sagittal plane, the subject started in a head neutral position, the metronome began beeping, and then the subject began flexing and extending their head-neck to reach full flexion on the first beep and reach full extension on the very next beep. They were asked to continue this motion without stopping until 5 trials had been recorded. The investigator allowed the subject to go through 2 to 3 full cycles of head motions in each plane before collection began in order to ensure the subject had time to achieve synchronization with the metronome. For consistency, each subject was instructed to stop at the end range of motion in which they felt the collar begin to restrict their motion. The testing order of the collars was first randomized and the movement order was

then randomized for each collar condition to eliminate any ordering or learning effects. Data Processing and Analysis 3D kinematic data were processed and analyzed using Visual 3D software suite (C- Motion, Inc., Germantown, MD). The rotational direction of the joint kinematics (angles) was determined using a right-hand-rule, and joint angles were calculated using an XYZ cardan rotation sequence. The maximum and minimum of flexion and extension, left and right lateral flexion, and left and right axial rotation, and the total range of motion of each of the three 3D movements for the head-thorax, head-collar, and collar-thorax angles were calculated and determined as variables of interest. Additionally, the head-trunk distraction was calculated for each collar condition. All variables of interest (minus head distraction) were analyzed from a neutral head position, through the full range of motion for each movement, until the head returned to the neutral position. For example, during flexion/extension, the data collection and analysis began when the head was neutral, and went through the full flexion and extension and ended when the head returned to neutral. For the head distraction, the distance between the trunk center of mass and the head center of mass was calculated for each collar condition using the static trial of each of the four collar conditions. Customized computer programs (VB_V2D and VB_Table) were used to determine critical events of the variables of interest from the output of Visual 3D, and were used to organize the variables for statistical analysis. A 2 4 (Gender x Collar) mixed design analysis of variance (ANOVA) was used to determine any differences between two genders and the three collars for selected kinematic variables (19.0, IBM SPSS, Chicago, IL). Post hoc comparisons were performed using a paired samples t-test if a significant Gender x Collar interaction was found. An alpha level of 0.05 was set a priori for all statistical procedures. RESULTS In order to examine the effects of the cervical collars on restrictions of the head-neck 3D movements, we examined the following variables of the angles between the head and trunk

segments: maximum flexion, extension, and total range of motion (ROM: max extension max flexion) in the sagittal plane, the maximum left and right lateral flexion and total ROM (max right rotation max left rotation) in the frontal plane, and the right rotation, left rotation and total ROM (max left rotation max right rotation) in the transverse plane. Ensemble curves of a representative subject for the 3D head-thorax movements are presented in Figure 3 for the no collar condition and in Figure 4 for the CCE collar condition. The two-way ANOVA results showed no significant gender main effect or gender by collar interaction. Therefore, the data were combined in the subsequent analyses to focus on effects on the collars on the restriction of movements. For the sagittal plane, the descriptive data and statistical results of the maximum flexion, extension, and total ROM of the head-thorax joint are provided in Table 1. The post hoc comparison results showed that the maximum flexion angle, maximum extension angle and total ROM were all reduced significantly for all three collars (p < 0.001) compared to the no collar condition (Table 1). The maximum extension angle was reduced in the CCE compared to Vista TX (p = 0.011). In addition, the total ROM was reduced in both Advanced (p = 0.043) and CCE (p = 0.042) compared to Vista TX. The descriptive data and statistical results of the maximum left and right flexion, and total ROM of the head-thorax joint in the frontal plane are provided in Table 2. The results indicated that the maximum left and right flexion and total lateral flexion ROM were all reduced significantly in the three collars (p < 0.001) compared to no collar (Table 2). The maximum left flexion angle was also decreased in Advanced (p = 0.002) and CCE (p < 0.001) compared to Vista TX. Similarly, the maximum right flexion angle and total ROM were also decreased in Advanced (p < 0.001 & p < 0.001) and CCE (p < 0.001 & p < 0.001) compared to Vista TX. For the transverse plane, the descriptive data and statistical results of the maximum right and left axial rotation and total axial rotation ROM of the head-thorax joint are provided in Table 3. The statistical results found that maximum left and right axial rotation angles and total ROM were all reduced significantly in the three collars (p < 0.001) compared to no collar (Table 3). In addition, the maximum right rotation and total axial rotation ROM were reduced

in CCE (p = 0.005 & p = 0.005) compared to Advanced. The peak left axial rotation angle was decreased in CCE (p = 0.031) compared to Vista TX. For the head and trunk distraction, there was a between-subject gender main effect (F = 30.8, p < 0.001) and the female subjects had smaller distraction values compared to their male counterparts (Figure 5). The post hoc comparison showed that the distraction was reduced only for CCE compared to no collar (p = 0.041, Figure 5).

Table 1. Mean peak flexion, extension, and total flexion-extension ROM of the head in the sagittal plane: mean ± STD. Variables (deg) No Collar Vista TX Advanced CCE F Value p Peak flexion -56.6±12.1-14.0±7.1 $ -12.6±7.8 $ -13.3±6.8 $ 76.2 < 0.001 Peak extension 50.6±15.8 17.4±7.9 $ 16.3±7.8 $ 13.6±5.8 $# 41.2 < 0.001 Total ROM 107.1±21.0 31.4±13.0 $ 28.9±11.0 $# 27.0±8.7 $# 154.6 < 0.001 Note: $ : Significantly different than No Collar, # : Significantly different than Vista TX, @ : Significantly different than Advanced. Table 2. Mean peak left and right lateral flexion and total lateral flexion ROM of the head in the frontal plane: mean ± STD. Variables (deg) No Collar Vista TX Advanced CCE F Value p Peak left lateral flexion -35.7±8.1-20.2±6.3 $ -15.9±7.0 $# -14.7±6.4 $# 56.6 < 0.001 Peak right lateral flexion 37.8±7.2 22.6±8.0 $ 18.3±8.2 $# 16.7±5.9 $# 55.7 < 0.001 Total lateral flexion ROM 73.5±13.5 42.8±13.5 $ 34.2±14.5 $# 31.4±11.2 $# 90.7 < 0.001 Note: $ : Significantly different than No Collar, # : Significantly different than Vista TX, @ : Significantly different than Advanced. Table 3. Mean peak left and right axial rotation and total axial rotation ROM of the head in the transverse plane: mean ± STD. Variables (deg) No Collar Vista TX Advanced CCE F Value p Peak right axial rotation -64.9±12.2-16.3±10.0 $ -17.0±10.0 $ -12.9±8.1 $@ 218.8 < 0.001 Peak left axial rotation 67.2±12.6 19.1±9.3 $ 18.6±11.3 $ 14.4±8.0 $# 228.5 < 0.001 Total axial rotation ROM 132.0±22.9 35.4±18.6 $ 35.6±20.3 $ 27.3±15.4 $#@ 236.6 < 0.001 Note: $ : Significantly different than No Collar, # : Significantly different than Vista TX, @ : Significantly different than Advanced.

A) B) C) Figure 3. Representative ensemble curves (mean solid line and shaded area 1 standard deviation) from one subject in A) flexion (negative) extension (positive), B) left (negative) right (positive) lateral flexion, and C) right (negative) left (positive) axial rotation of head movements in the no collar control condition.

A) B) C) Figure 4. Representative ensemble curves (mean solid line and shaded area 1 standard deviation) from one subject in A) flexion (negative) extension (positive), B) left (negative) right (positive) lateral flexion, and C) right (negative) left (positive) axial rotation of head movements in the CCE collar.

Distance (m) 0.30 0.28 0.26 0.24 Male Female Total 0.22 0.20 No Collar Vista Advanced DeRoyal Figure 5. Mean head-thorax distraction values for the four collar conditions for female, male and all subjects. DISCUSSION Sagittal Plane Movements All three collars reduced similar amounts of head flexion ROM (Table 1). The mean reduction of head flexion ROM was 43.3 or 76.5% across all three collars compared to no collar (control condition). Specifically, the reductions were 43.2 (76.4%) for CCE, 42.5 (75.2%) for Vista TX, and 44.0 (77.8%) for Advanced. The mean reduction of head extension ROM was 34.8 or 68.8%. These reductions were 36.9 (73.0%) for CCE, 33.1 (65.6%) for Vista TX, and 34.2 (67.7%) for Advanced. There were statistical differences in the amount of reductions among the collars. The CCE collar reduced more head extension ROM than Vista TX, for an average of 3.7 or 7.4% more reduction. The mean reduction of head sagittal-plane total ROM was 78.0 or 72.8%. Specifically, the reductions were 80.1 (74.8%) for CCE, 75.7 (70.6%) for Vista TX, and 78.2 (73.0%) for Advanced. The statistical comparisons showed that CCE and Advanced collars reduced more head total ROM compared to the Vista TX collar, at an average of 4.5 or 4.2% and 2.6 or 2.4% more reduction, respectively.

Frontal Plane Movements Both CCE and Advanced collars reduced significantly more head left and right flexion ROM and total lateral flexion ROM, compared to the Vista TX collar (Table 2). The mean reduction of head left lateral flexion ROM for all three collars was 18.8 or 52.6% compared to no collar. The specific reductions of head left lateral flexion ROM were 21.1 (58.9%) for CCE, 15.5 (43.3%) for Vista TX, and 19.8 (55.5%) for Advanced. Both CCE and Advanced collars reduced more head left lateral flexion than Vista TX, for 5.6 or 15.5% and 4.3 or 12.1% more reduction, respectively. In addition, the mean reduction of head right lateral flexion ROM was 18.6 or 49.2% for all three collars compared to the no collar condition. The specific reductions of head right lateral flexion ROM were 21.0 (55.7%) for CCE, 15.2 (40.2%) for Vista TX, and 19.5 (51.6%) for Advanced. Both CCE and Advanced collars reduced more head right lateral flexion than Vista TX, for 5.8 or 15.5% and 4.3 or 11.4% more reduction, respectively. Finally, the mean reduction of total head lateral flexion ROM was 37.4 or 50.8% for all three collars compared to the no collar condition. The specific reductions of head total lateral flexion ROM were 42.1 (57.2%) for CCE, 30.7 (41.7%) for Vista TX, and 39.3 (53.5%) for Advanced. Both CCE and Advanced collars reduced more head right lateral flexion than Vista TX, at 11.4 or 15.5% and 8.6 or 11.7% more reduction, respectively. Transverse Plane Movements Both CCE and Advanced collars reduced significantly more head right axial flexion ROM and total axial rotation ROM, compared to the Vista TX collar (Table 3). The CCE collar also reduced more left head axial rotation compared to Vista TX. The mean reduction of head right axial rotation ROM for all three collars was 49.5 or 76.3% compared to the no collar condition. The specific reductions of head right axial rotation ROM were 51.9 (80.1%) for CCE, 48.6 (74.9%) for Vista TX, and 47.9 (73.8%) for Advanced. CCE collar reduced more head right axial rotation than both Vista TX and Advanced, for 3.3 or 5.2% and 4.0 or 6.2% more reduction, respectively. In addition, the mean reduction of head left axial rotation ROM was 49.8 or 74.2% for all three collars compared to the no collar condition. The specific reductions of head left axial rotation ROM were 52.8 (78.6%) for CCE, 48.1 (71.6%) for Vista TX, and 48.6 (72.3%)

for Advanced. CCE collar reduced more head left axial rotation than Vista TX, for 4.7 or 7.1% more reduction. Finally, the mean reduction of total head axial ROM was 99.3 or 75.2% for all three collars compared to the no collar condition. The specific reductions of head total axial rotation ROM were 104.7 (79.3%) for CCE, 96.6 (73.2%) for Vista TX, and 96.5 (73.1%) for Advanced. CCE collar reduced more total head axial rotation ROM than both Vista TX and Advanced, at 8.1 or 5.1% and 8.3 or 6.2% more reduction, respectively. Head Distraction The head distraction values were captured and measured by the distances between the center of gravity of the head and trunk in the static trials for no collar, Vista TX, Advanced and CCE conditions. As expected, the distraction values were greater for males compared to females. However, there was a significant reduction of this value for the CCE compared to no collar. But the reduction was only less than 1%. Therefore, the adjustable support structure of CCE is not considered to have significant effect of distraction between the head and trunk segment. Conclusion In conclusion, the study results demonstrated that both Capital Collar Enhanced and Miami J Advanced cervical collars had greater effects on restricting head-neck movements in flexion-extension and lateral flexion. However, the Capital Collar Enhanced showed greater restriction on axial rotations of head-neck than Miami J Advanced and Aspen Vista TX collars. No apparent effects of the adjustable support structure on the head distractions were observed for all three tested cervical collars.

REFERENCES Johnson, R. M., Hart, D. L., Simmons, E. F., Ramsby, G. R., & Southwick, W. O. (1977). Cervical orthoses. A study comparing their effectiveness in restricting cervical motion in normal subjects. J Bone Joint Surg Am, 59, 332-339. Richter, D., Latta, L. L., Milne, E. L., Varkarakis, G. M., Biedermann, L., Ekkernkamp, A., & Ostermann, P. A. (2001). The stabilizing effects of different orthoses in the intact and unstable upper cervical spine: a cadaver study. J Trauma, 50, 848-854. White, A. A., & Panjabi, M. M. (1990). Spinal braces: Functional analysis and clinical applications. In A. A. White & M. M. Panjabi (Eds.), Clinical biomechanics of the spine (pp. 475-511). Philadelphia: J.B. Lippincott Company.

ACKNOWLEDGEMENTS We would like to acknowledge the assistance provided by Chen Wen in data processing and analysis.