ULTRASOUND QA SOLUTIONS. Ensure Accurate Screening, Diagnosis and Monitoring DOPPLER FLOW PHANTOMS MULTI-PURPOSE PHANTOMS TRAINING PHANTOMS

Similar documents
ULTRASOUND QA SOLUTIONS. Ensure Accurate Screening, Diagnosis & Monitoring DOPPLER FLOW PHANTOMS MULTI-PURPOSE PHANTOMS TRANSDUCER TEST PHANTOMS

ULTRASOUND QA SOLUTIONS. Ensure Accurate Screening, Diagnosis & Monitoring DOPPLER FLOW PHANTOMS MULTI-PURPOSE PHANTOMS TRANSDUCER TEST PHANTOMS

Underwater Acoustic Measurements in Megahertz Frequency Range.

Outline. QA/QC of Ultrasound Imagers: Basic Physics, Procedures and Experiences. Frame Rate Limitation. US Imaging Range Equation.

Routine Quality Assurance Cookbook

TG-128: Quality Assurance for Prostate Brachytherapy Ultrasound

Hands-On Ultrasound Physics and Quality Control Workshop. Outline

Optimizer 1425A. User s Guide. Ultrasound Image Analyzer for Doppler and Grey Scale Scanner. België / Belgique. Nederland.

Quality Control Program Of Real Time Medical Ultrasound Machines In Sudan

Debbie Childs RDMS, RVT Sonographer Murphy Medical Center Murphy, NC

BICOE Breast Imaging Center of Excellence. What is it? - Requirements. National Mammography Database. What do you get? ACR Accreditation in:

Current Ultrasound Quality Control Recommendations and Techniques

Diploma of Medical Ultrasonography (DMU) Physical Principles of Ultrasound and Instrumentation Syllabus

When You Need To Know More.

Ultrasound in Medicine

Principles of Ultrasound. Cara C. Prideaux, M.D. University of Utah PM&R Sports Medicine Fellow March 14, 2012

Performance Evaluation of Ultrasound Systems: Advanced Methods and Applications

8/3/2016. Diagnostic Ultrasound Imaging Quality Assurance. Purpose. Information on US QA. James A. Zagzebski 1, Ph.D. Zheng Feng Lu 2, Ph.D.

Xperius Ultrasound System Responsive Advanced Simple NEW

ULTRASOUND. OB/Gyn (Core) Ultrasound PIEZOELECTRIC EFFECT. Principles of Ultrasound Physics and Instrumentation. Nathan Pinkney, BS, CDOS

BICOE Stereotactic Breast Biopsy and Breast Ultrasound Accreditation. Introduction. Educational Objectives

BICOE Stereotactic Breast Biopsy and Breast Ultrasound Accreditation. Introduction. Educational Objectives

GE Healthcare 9900 Innovation Drive Wauwatosa, WI U.S.A.

Ultrasound Applied Physics

Intuitive. Intelligent. Innovative. General Imaging

Performance of phased array and conventional ultrasonic probes on the new ISO reference block

Terminology Tissue Appearance

Physical Principles of Ultrasound

Confident Diagnosis, Confident Decisions

Medical Physics 2.0. Ultrasound 2.0. N. J. Hangiandreou, Ph.D. 1 P. L. Carson, Ph.D. 2 Z. F. Lu, Ph.D. 3. Mayo Clinic 2. University of Michigan 3

WELCOME! Introduction to Bedside Ultrasound

SONIMAGE HS1. Premium Portable Ultrasound

Premium performance compact ultrasound. Philips CX50 POC CompactXtreme ultrasound system

ACUSON P500. Ultrasound Anytime, Anywhere. ACUSON P500. siemens.com/acusonp500. siemens.com/acusonp500 1

ALPINION MEDICAL SYSTEMS We are Ultrasound Professionals

All-in-one Solution for Top Performers

High resolution ultrasound scanner for skin imaging

Basic of Ultrasound Physics E FAST & Renal Examination. Dr Muhammad Umer Ihsan MBBS,MD, DCH CCPU,DDU1,FACEM

Ultrasound & Laser Therapy

Preamble (disclaimer)

DC-6. Diagnostic Ultrasound System

Transducers. ACUSON SC2000 Ultrasound System. Precision at the Speed of Life Release 5.0

Ultrasound Physics & Terminology

THE VALUE INNOVATIVE ULTRASOUND SYSTEM

The Value. Ultrasound System. Professional Concept for. Women s. Health

Quality Assurance of Ultrasound Imaging in Radiation Therapy. Zuofeng Li, D.Sc. Murty S. Goddu, Ph.D. Washington University St.

Hands-on. Physics Workshop. 2-day Workshop June 1-2, 2018 Ann Arbor, MI. Program Director: Brian Fowlkes, PhD

Confident and Conclusive Diagnosis with Flexible Solutions

Aixplorer MultiWave Ultrasound System An Innovation in Breast Ultrasound Imaging

ZONARE Ultrasound for the Emergency Department. Living Technology

1 Fundamentals. Basic Definitions and Physics Principles. Fundamentals

Ultrasonic Testing Level I:

ULTRASONIC ARRAY APPROACH FOR THE EVALUATION OF ELECTROFUSION JOINTS OF POLYETHYLENE GAS PIPING

How can I provide her with the most advanced care?

An Audit of a Hospital-Based Doppler Ultrasound Quality Control Protocol Using a Commercial String Doppler Phantom

Transducers. ACUSON SC2000 Ultrasound System. Release 4.0. Answers for life.

Linear Ultrasonic Wave Propagation in Biological Tissues

Features and Benefits

Basic Physics of Ultrasound and Knobology

The Veterinarian s Choice. Delta Six.

Development of Ultrasound Based Techniques for Measuring Skeletal Muscle Motion

ZONARE Vascular Radiology. Living Technology ZONARE Medical Systems, Inc. All rights reserved. Printed in U.S.A.

ACUSON P500. Ultrasound Anytime, Anywhere. ACUSON P500. siemens.com/acusonp500. siemens.com/acusonp500 1

Design Your Performance

Point-of-Care Ultrasound: An Introduction

Premium Ultrasound. Eight.

Premium performance compact ultrasound

The Evolution and Benefits of Phased Array Technology for the Every Day Inspector

The complete, portable patient care solution

Intuitive. Intelligent. Innovative. General Imaging

Dr Emma Chung. Safety first - Physical principles for excellent imaging

Introduction. Table of Contents

ULTRASOUND IMAGING EE 472 F2018. Prof. Yasser Mostafa Kadah

A new method of sonograph lateral resolution measurement using PSF analysis of received signal

powerful versatile mobile

LOGIQ E9 with XDclear

Full ultrasound breast volumes. Faster scans. Streamlined workflow. ACUSON S2000 Automated Breast Volume Scanner. Answers for life.

GE Healthcare. Vivid i Cardiovascular ultrasound system

The Portable Performance

CONTENTS. Test Number cpd Tanya Reynolds (Nat. Dip. Diag. Rad., B. Tech. Diag. Rad., B. Tech. Ultrasound)

Training and qualification inspectors for advanced GWT inspections. David Alleyne 7MENDT, Bahrain 14 September 2015

ACUSON X500 Ultrasound System. Transducers

The Physics of Ultrasound. The Physics of Ultrasound. Claus G. Roehrborn. Professor and Chairman. Ultrasound Physics

The table below shows the density and velocity of waves in two different substances. Density / kg m 3 Velocity / m s 1

High performance compact ultrasound

Application of Phased Array Radar Theory to Ultrasonic Linear Array Medical Imaging System

Annular Array Transducer and Matched Amplifier for Therapeutic Ultrasound

3/20/2017. Disclosures. Ultrasound Fundamentals. Ultrasound Fundamentals. Bone Anatomy. Tissue Characteristics

High performance compact ultrasound

Descriptions of NDT Projects Fall 2004 October 31, 2004

Lesson 07: Ultrasound Transducers. This lesson contains 73 slides plus 16 multiple-choice questions.

DIGITAL IMAGE PROCESSING IN ULTRASOUND IMAGES

DELGADO COMMUNITY COLLEGE DIAGNOSTIC MEDICAL SONOGRAPHY PROGRAM TECHNICAL STANDARDS

APPLICATION AND DEPLOYMENT OF ADVANCED NDE TECHNIQUES IN HIGH PRESSURE VESSELS

Introduction. The goal of TRUS QA is to ensure your system can do all of this accurately.

Intuitive. Intelligent. Innovative. General Imaging

Ultrasound Principles cycle Frequency Wavelength Period Velocity

Delivering Top Performance. Outstanding Value. Exceptional Reliability. ACUSON X150 Ultrasound System. Answers for life.

Transcription:

ULTRASOUND QA SOLUTIONS Ensure Accurate Screening, Diagnosis and Monitoring DOPPLER FLOW PHANTOMS MULTI-PURPOSE PHANTOMS TRAINING PHANTOMS

INNOVATORS IN ADVANCED ULTRASOUND TECHNIQUES Gammex is the only ultrasound QA solutions manufacturer with expertise in medical physics since 1969. We collaborated with clinical and academic thought and system settings are fully tested across the leaders to develop our patented HE Gel and the first entire frequency range from 2 to 18 MHz. Our HE portable Doppler Flow phantoms in the world. Gel combined with our medical physics and quality HE (High Equivalency) Gel sets Gammex ultrasound control expertise gives you confidence with consistent products apart; it helps ensure all your transducers 2 SUN NUCLEAR CORPORATION // sunnuclear.com diagnostic image quality in clinical applications.

HE Gel has superior longevity and provides multi-frequency, high quality, reproducible images. A critical consideration in the selection of an ultrasound phantom The higher the frequency response, the less depth of penetration. This can lead to a deterioration in axial resolution and penetration depth measurements at higher frequencies, and potentially can produce QC and performance results which are not representative of tissue. 1,2,3 Gammex HE Gel solves these potential issues. HE Gel : Gammex s patented multi-frequency TMM Frequency Range 4 : Speed of Sound: Attenuation Coefficient: Variation of attenuation with frequency 4,5 : 2 18 MHz 1540 m/s 0.5 or 0.7 db/cm/mhz f 1.08 at 0.5 db/cm/mhz f 1.1 at 0.7 db/cm/mhz Exceeds ACR, AIUM and other international program requirements Very uniform with a nonlinearity parameter (B/A) equivalent to human liver Near-linear variation of attenuation with frequencies between 2 to 18 MHz 4,5 Over 8 MHz, HE Gel supports accurate ate axial resolution and penetration depth representative of human tissue 1,4 1 Goldstein, A., The Effect of Acoustic Velocity on Phantom Measurements. Ultrasound in Medicine and Biology, Vol. 26, pp. 1133-1143, 2003. 2 O Donnell, M., Miller, J., Mechanisms of Ultrasonic Attenuation in Soft Tissue. Ultrasonic Tissue Characterization II. NBS Spec. Publ. 525, ed M. Linzer (Washington, DC: US Govt. Printing Office) pp. 37-40, 1979. 3 Browne, J., Ramnarine, K., Hoskins, P., Watson, A., A Comparative Study of the Physical Properties of Five Commonly Used Ultrasound Test Phantoms. Ultrasound in Medicine, pp. 21:S9, 2002. 4 Browne, J., Ramnarine, K., Watson, A., Hoskins, P., Assessment of the Acoustic Properties of Common Tissue-Mimicking Test Phantoms. Ultrasound in Medicine and Biology, Vol. 29 (7), pp. 1053-1060, 2003. 5 Near-linear responses of attenuation with frequencies between 2 to 18 MHz support accurate axial resolution and penetration depth representative of human tissue. sue. SUN NUCLEAR CORPORATION // sunnuclear.com 3

Ultrasound Solutions // DOPPLER FLOW & B-MODE Doppler 403 Flow and Mini- Doppler 1430 Flow phantoms assess system velocities using precision flow rates and Gammex s proprietary bloodmimicking fluid. DOPPLER 403 AND MINI-DOPPLER 1430 FLOW PHANTOMS The leading QA solution in ultrasound. The all-in-one Doppler flow Phantoms with B-Mode included. The best of both worlds. These rugged, self-contained and battery-operated systems help cover all your Ultrasound QC needs and exceed ACR requirements. Precision flow rates (constant and parabolic) mimic blood flow in human vessels and allow you to reliably test system velocities. Whether you require the full capabilities of the Doppler 403 Flow Phantom or the specialized small parts capabilities of the Mini-Doppler 1430 Flow Phantom, we have the solution for you. 4 SUN NUCLEAR CORPORATION // sunnuclear.com

Consistency with a Gammex Doppler Flow phantom... means confidence in your patient s assessment. With Doppler Flow Phantoms, go from storage to use in less than 10 seconds. Both Phantoms include advanced features that provide years of consistent QC measurements and high quality diagnostic imaging. Common Highlights Patented multi-frequency HE Gel Constant and pulsatile flow modes Rugged, self-contained, battery-operated Mini-Doppler 1430 Flow Phantom Ideal for cardiology and musculoskeletal (MSK) applications Portable and lightweight (<10 lbs / 4.6 kg) Doppler 403 Flow Phantom The reference standard in Doppler Ultrasound QA Laminar and parabolic flows are available (velocity dependent) Includes the Sono Transducer Holder New blood mimicking fluid formulation - Increased viscosity and decreased Reynolds number - No need to ever purchase or store blood mimicking fluid Specifications Doppler 403 Flow Phantom Mini-Doppler 1430 Flow Phantom Performance Measures: Image uniformity, artifact survey, axial and lateral resolution, horizontal and vertical distance, dead zone, depth of penetration, signal-to-noise ratio, anechoic and echogenic mass resolution, and gray scale contrast resolution Vessels (2): 5mm inner diameter; 1 horizontal at 2 cm depth, 1 diagonal at 40º from 2 to 16 cm deep 4mm inner diameter; 1 horizontal at 2 cm depth, 1 diagonal at 35º from 2 to 9 cm deep Flow rates: Customizable, constant and pulsatile Customizable, constant and pulsatile Blood Mimicking Fluid: Speed of Sound 1550 ± 10 m/s, total volume approx. 300 ml Speed of Sound 1550 ± 10 m/s, total volume approx. 100 ml Targets: Strings, cysts, grey scale, resolution groups Strings, cysts, grey scale, resolution groups Dimensions (Case): 28 H x 30.5 W x 22 cm D (11 x 12 x 8.65 in.) 20 H x 23 W x 15.2 cm D (7.87 x 9.06 x 5.94 in) Weight: 8.34 kg (18 lbs. 4 oz.) 4.6 kg (9 lbs. 15oz.) SUN NUCLEAR CORPORATION // sunnuclear.com 5

Ultrasound Solutions // Sono Family ADVANCED SONO LINEUP FOR QC AND TRAINING We can help simplify the transition from QC testing to clinical use. Our B-mode phantoms are reliably used to test ultrasound systems using clinical settings to save time during QC. Sono403 The Sono403 Multi-Purpose Phantom exceeds the ACR guidelines and recommendations for ultrasound QA. It has precision-placed targets for measuring system grey scale and axial resolution. The depth of the phantom is designed to simulate the typical depth through the abdomen to the liver. The Sono403 family includes the 403 SCG and 403 SC models with complex to simple targets. Sono410 The Sono410 Phantom features a Full Contact curved scanning surface, which improves coupling between convex transducers and the phantom scanning window. Invert the phantom 180 degrees, and use the patented scanning interface for linear arrays. Check resolution against published limiting values with the targets at 80 and 150 mm, or apply the Skolnick method. The Sono410 Phantom family includes the 410 SCG, 410 SC and 410 S models with complex to simple targets. Sono408 The Sono408 Spherical Lesion Phantom provides a unique way to test resolution performance in three dimensions: axial, lateral and elevational. Designed in collaboration with researchers to meet their precise specifications. 6 SUN NUCLEAR CORPORATION // sunnuclear.com

Sono404 The Sono404 Small Parts Phantom provides training and testing for the most difficult cases. Pin targets are vertically spaced at 5 mm from 1 to 9 cm deep to measure image quality of small parts for ultrasound systems used in breast care centers and MSK. Test your high frequency transducers routinely to ensure precise measurements with patients. The Sono404 Phantom family includes the 404 SCG and 404 SC models with complex to simple targets. Sono TE The Sono TE Phantom is a low-cost, high-value ultrasound transducer evaluation device. It provides affordable uniformity tests for linear, convex and intercavity transducers. Excellent for quick transducer tests and training. Sono Transducer Holder The Sono Transducer Holder fits any Gammex phantom including the Doppler Flow and Sono (B-mode) phantoms. Place a transducer in a precise location for reproducible tests over time Use the cable hook to contain the cable Rejuvenation Will Protect Your Investment Our Doppler Flow and Sono (B-Mode) phantoms are the only ultrasound phantoms on the market that can be rejuvenated and re-validated. Implementing a rejuvenation program can extend the life of your phantoms to 10+ years. Specifications (Sono) Feature Sono403 SCG Multi-Purpose Sono404 SCG Small Parts Sono410 SCG Full Contact Sono408 Spherical Lesion Patented HE Gel Speed of Sound 1540 m/s Frequency Range 2-18 MHz Patented composite film scanning surface String/Pin targets- vertical 20 mm at 2 to 16 cm deep 5 mm at 1 to 9 cm deep 1, 2 and 4 cm at 1 to 15 cm deep String/Pin targets- horizontal 30 mm at 2 to 12 cm deep 10 mm at 1 and 5 cm deep 2 cm at 2 cm deep, 4 cm at 7 and 13 cm deep Anechoic Cysts (mm) 2, 4, 6, 10 mm diameter 1, 2, 4, 7 mm diameter 12 targets, 1, 2, 4, 8 mm diameter Grey Scale (db) 3 targets, 10 mm diameter, -6, +6 and +12 3 targets, 7 mm diameter, -6, +6 and +12 6 targets, 8 mm diameter, -6, +6 and +12 Full Contact Curved Scanning surface Anechoic Spherical Lesions 211 4 mm diameter lesions spaced vertically at 0.5 cm apart and horizontally at 0.75 cm apart, 105 2 mm diameter lesions spaced at 0.5 cm apart vertically & horizontally Revalidation reports available Exceeds ACR and other program requirements SUN NUCLEAR CORPORATION // sunnuclear.com 7

Gammex is a leader in advanced ultrasound techniques, and we have the expertise and technical knowledge to support your Quality Assurance programs. Call us or visit our website for details. +1 608-828-7000 // sunnuclear.com Gammex Corporate Headquarters: 7600 Discovery Drive, Middleton, WI 53562 800-426-6391 (800-GAMMEX-1) 2017 Sun Nuclear Corporation. All Rights Reserved. All data used is best available at time of publication. Data is subject to change without notice. UltrasoundSolutions_D020317