Goal-directed vs Flow-guidedresponsive

Similar documents
Fluids: occult effects. S Magder Department of Critical Care, McGill University Health Centre

FUNDAMENTALS OF HEMODYNAMICS, VASOACTIVE DRUGS AND IABP IN THE FAILING HEART

Hemodynamic Monitoring Pressure or Volumes? Antonio Pesenti University of Milan Italy

Early Goal-Directed Therapy

Fluids in Sepsis: How much and what type? John Fowler, MD, FACEP Kent Hospital, İzmir Eisenhower Medical Center, USA American Hospital Dubai, UAE

Obligatory joke. The case for why it matters. Sepsis: More is more. Goal-Directed Fluid Resuscitation 6/1/2013

Introduction. Invasive Hemodynamic Monitoring. Determinants of Cardiovascular Function. Cardiovascular System. Hemodynamic Monitoring

Evidence-Based. Management of Severe Sepsis. What is the BP Target?

UTILITY of ScvO 2 and LACTATE

Goal-directed resuscitation in sepsis; a case-based approach

Surviving Sepsis Campaign Guidelines 2012 & Update for David E. Tannehill, DO Critical Care Medicine Mercy Hospital St.

Sepsis Wave II Webinar Series. Sepsis Reassessment

Impedance Cardiography (ICG) Method, Technology and Validity

SHOCK. Emergency pediatric PICU division Pediatric Department Medical Faculty, University of Sumatera Utara H. Adam Malik Hospital

Sepsis Update: Focus on Early Recognition and Intervention. Disclosures

Full Disclosure. The case for why it matters. Goal-directed Fluid Resuscitation

The Use of Dynamic Parameters in Perioperative Fluid Management

Failure of the circulation to maintain Tissue cellular. Tissue hypoperfusion Cellular hypoxia SHOCK. Perfusion

The Septic Patient. Dr Arunraj Navaratnarajah. Renal SpR Imperial College NHS Healthcare Trust

Nurse Driven Fluid Optimization Using Dynamic Assessments

FloTrac Sensor and Edwards PreSep Central Venous Oximetry Catheter Case Presentations

CARDIAC OUTPUT Monitoring ANDY CAMPBELL JOURNAL CLUB NOV 2011

Cardiopulmonary System

Bedside assessment of fluid status

Dr. F Javier Belda Dept. Anesthesiology and Critical Care Hospital Clinico Universitario Valencia (Spain) Pulsion MAB

Hemodynamic Monitoring and Circulatory Assist Devices

Department of Intensive Care Medicine UNDERSTANDING CIRCULATORY FAILURE IN SEPSIS

The Vigileo monitor by Edwards Lifesciences supports both the FloTrac Sensor for continuous cardiac output and the PreSep oximetry catheter for

Cardiovascular Management of Septic Shock

Shock, Monitoring Invasive Vs. Non Invasive

The Vigileo monitor by Edwards Lifesciences supports both the FloTrac Sensor for continuous cardiac output and the PreSep oximetry catheter for

Swans and Pressors. Vanderbilt Surgery Summer School Ricky Shinall

Swans and Pressors. Vanderbilt Surgery Summer School Ricky Shinall

Case year old female nursing home resident with a hx CAD, PUD, recent hip fracture Transferred to ED with decreased mental status BP in ED 80/50

Cardiac Output Monitoring - 6

Fluid Resuscitation and Monitoring in Sepsis. Deepa Gotur, MD, FCCP Anne Rain T. Brown, PharmD, BCPS

Presented by: Indah Dwi Pratiwi

Early-goal-directed therapy and protocolised treatment in septic shock

FLUID RESUSCITATION AND MONITORING IN SEPSIS PROTOCOLIZED VS USUAL CARE DEEPA BANGALORE GOTUR MD, FCCP ASSISTANT PROFESSOR, WEILL CORNELL MEDICAL

towards early goal directed therapy

Staging Sepsis for the Emergency Department: Physician

Assessing Preload Responsiveness Using Arterial Pressure Based Technologies. Patricia A. Meehan, RN, MS Education Consultant Edwards Lifesciences, LLC

How and why I give IV fluid Disclosures SCA Fluids and public health 4/1/15. Andrew Shaw MB FRCA FCCM FFICM

Prof. Dr. Iman Riad Mohamed Abdel Aal

What you need. When you need it. EV1000 Clinical Platform

Vasopressors in septic shock

Cath Lab Essentials: Basic Hemodynamics for the Cath Lab and ICU

FLUIDS AND SOLUTIONS IN THE CRITICALLY ILL. Daniel De Backer Department of Intensive Care Erasme University Hospital Brussels, Belgium

How can the PiCCO improve protocolized care?

DESIGNER RESUSCITATION: TITRATING TO TISSUE NEEDS

EVOLUCIÓN DE LA MONITORIZACIÓN CARDIOVASCULAR EN LA UCI

3/14/2017. Disclosures. None. Outline. Fluid Management and Hemodynamic Assessment Paul Marik, MD, FCCP, FCCM

Hemodynamic monitoring beyond cardiac output

Dilemmas in Septic Shock

Tailored Volume Resuscitation in the Critically Ill is Achievable. Objectives. Clinical Case 2/16/2018

Effects of mechanical ventilation on organ function. Masterclass ICU nurses

Making the Case For Less Invasive Flow Based Parameters: APCO + SVV. Patricia A. Meehan, RN, MS, CCRN (a) Education Consultant Edwards Lifesciences

PiCCO based algorithms

Radboud University Nijmegen Medical Centre Why measure cardiac output in critically ill children?

PulsioFlex Patient focused flexibility

การอบรมว ทยาศาสตร พ นฐานทางศ ลยศาสตร เร อง นพ.ส ณฐ ต โมราก ล ภาคว ชาว ส ญญ ว ทยา คณะแพทยศาสตร โรงพยาบาลรามาธ บด มหาวทยาลยมหดล

Albumina nel paziente critico. Savona 18 aprile 2007

Sepsis: Identification and Management in an Acute Care Setting

EARLY GOAL DIRECTED THERAPY : seminaires iris. Etat des lieux en Daniel De Backer

From PV loop to Starling curve. S Magder Division of Critical Care, McGill University Health Centre

Sepsis Management Update 2014

Cytoreductive Surgery and Hyperthermic Intraperitoneal Chemotherapy

Rounds in the ICU. Eran Segal, MD Director General ICU Sheba Medical Center

Titrating Critical Care Medications

IV fluid administration in sepsis. Dr David Inwald Consultant in PICU St Mary s Hospital, London CATS, London

Shock and hemodynamic monitorization. Nilüfer Yalındağ Öztürk Marmara University Pendik Research and Training Hospital

Relax and Learn At the Farm 2012

Evolutionary origins of the right ventricle. S Magder Department of Critical Care, McGill University Health Centre

Topics to be Covered. Cardiac Measurements. Distribution of Blood Volume. Distribution of Pulmonary Ventilation & Blood Flow

CARDIOVASCULAR MONITORING. Prof. Yasser Mostafa Kadah

Shock Quiz! By Clare Di Bona

Fluid balance and clinically relevant outcomes

Sepsis Combine experience and Evidence. Eran Segal, MD Director General ICU, Sheba Medical Center, Israel

Physiologic Based Management of Circulatory Shock Kuwait 2018

Perioperative Goal- Protocol Summary

Revision of 10/27/2017 Form #280 Page 1 of 12 PVDOMICS STUDY Clinical Center Right Heart Catheterization (RHC) Results Form #280

IN THE NAME OF GOD SHOCK MANAGMENT OMID MORADI MOGHADDAM,MD,FCCM IUMS ASSISTANT PROFESSOR

Perioperative Goal- Protocol Summary

6/5/2014. Sepsis Management and Hemodynamics. 2004: International group of experts,

Pediatric Septic Shock. Geoffrey M. Fleming M.D. Division of Pediatric Critical Care Vanderbilt University School of Medicine Nashville, Tennessee

Chapter 9, Part 2. Cardiocirculatory Adjustments to Exercise

Low Cardiac Output in the Pediatric Patient

The Vigileo monitor by Edwards Lifesciences supports both the FloTrac Sensor for continuous cardiac output and the Edwards PreSep oximetry catheter

Calculations the Cardiac Cath Lab. Thank You to: Lynn Jones RN, RCIS, FSICP Jeff Davis RCIS, FSICP Wes Todd, RCIS CardioVillage.

DIAGNOSIS AND MANAGEMENT OF ACUTE HEART FAILURE

Management of Cardiogenic Shock. Dr Stephen Pettit, Consultant Cardiologist

Troubleshooting Audio

TOPIC : Cardiogenic Shock

What is. InSpectra StO 2?

The Hemodynamic Puzzle

Norepinephrine in septic shock

Sepsis Awareness and Education

Perioperative Fluid Management in ERPs

What works in sepsis. Topics. EGDT: Severe Sepsis/ Shock. Sepsis

Early Goal Directed Therapy in 2015: What Did the Big Trials Teach us?

Transcription:

Goal-directed vs Flow-guidedresponsive therapy S Magder Department of Critical Care, McGill University Health Centre Flow-directed vs goal directed strategy for management of hemodynamics S Magder Curr Opin Crit Care 2016; 22: 267-273

SHOCK: oxygen consumption is inadequate flow for metabolic needs.. Fick Equation VO 2 = Q x (C a O 2 - C v O 2 ) HR and SV Hb PO 2 = oxygen delivery Requires mitochondrial function

What can increase O 2 delivery?.. DO 2 = Q x Hb x k x Sat a Volume (preload) Blood Contractility HR Afterload PO2 Usually not much gain

1990 s targeted supra-normal values of DO 2 1994 Patients did worse 1993 1995 Patients did better

What was the difference between the ve and +ve trials? Haye s and Gattinoni (-ve trials) were in septic (inflamed) patients Boyd s study was on perioperative high risk surgical pts. Need to treat septic and perioperative studies differently In sepsis therapy is directed at returning values towards normal In perioperative management therapy is directed at avoiding downward drift and loss of normal organ function from volume loss and vascular depression from anesthesia

ProCESS American 2014 Rivers trial Goal-directed era ProMISe British 2015 ARISE ANZICS 2014

Mortality Percent Percent Time(d) Control EGDT Year Rivers 60 49.2 33.5 2001 ProCESS 60 18.5 21 2014 ARISE 90 18.8 18.6 2014 ProMISe 90 29.2 29.5 2015 Message We are doing better based on good clinical Decrease in judgement mortality of Rather than being Goal-directed control monitoring protocols should be used to group indicate whether the therapy corrected a problem that the clinician identified ie responsive approach EGDT More fluids More vasoactive drugs More PRBC More organ failure Longer stay

Mortality (%) High risk surgical pt also improved dramatically (Control pt in GDT Sx studies) 25 20 15 10 Boyd Pearce 1 5 0 1990 1995 2000 2005 2010 2015 2020 Year Pearce 2 -ve study

There is no evidence to defend these Goals in Rivers: CVP 8-12 mmhg Mean BP 65-90 CvO 2 sat 70% Hct 30 goals Goals in Surgical studies Boyd mbp 80-110 Ppao 12-14 Hb >120 DO 2 600 (vol and dopexamine) Pearce Colloid for maximum SV (LiDCo) (Treated 1500 ml vs Control 2600 ml) Dopexamine at a fixed dose Hb 80 g/l mbp 60-100 mmhg Sat 90%

Goal-directed protocols push patients to the plateau of the cardiac function curve Q Plateau In the plateau range the normal Starling mechanism is not operative and only HR, contractility and afterload can change cardiac output Pra

We function normally with a relatively constant volume (except for adjustments in stressed and unstressed volume) Flow involves redistributing the volume and creating pressure differences across vascular beds

Since volume does not change much, preload is not a major mechanism for increasing cardiac output in normal physiology Preload functions to fine tune the heart and matches cardiac output to changes in venous return CVP/Pra is determined by interaction of cardiac function and return function Little change in Pra during exercise

Cardiac output (l/min) Pra vs Cardiac Output during incremental exercise 35-30- 25-20- 15-10- 5- Little change in CVP No volume needs to be added to reach the high cardiac output at peak exercise! 0- -5 0 5 10 15 20 25 30 35 40 Right Atrial Pressure (mmhg Notarius et al Am Heart J 1998

Number of Pt CVP at Plateau (ie non-responsive) is variable 60 25% 45% 82% 100% 50 40 30 One size does not fit all! 20 total res non res 10 0 cvp 0-5 cvp 6-10 cvp 11-15 cvp 16-20 mmhg Bafaqeeh & Magder JICM 2007

ScvO 2 Volume could potentially decrease the value by lowering Hb Does it really need to by > 70%? Can fall with increased wakefulness/agitation Restoration of O 2 debt Only tells you upper body and not lower

Reactive Flow-Directed Approach

An abnormality ( trigger ) develops that you believe indicates a decrease in O 2 delivery Change in sensorium Decrease in urine output Hypotension Increase in lactate Fall in central venous saturation You hypothesize that volume may help. A reactive approach tests the hypothesis.

Where did the volume go? Septic patient 1. Capillary leak 2. Increase in capacitance 3. Lack of regulation of resistances re-distributes flow to areas of low need 4. Lack of intake because of altered sensorium Surgical patient in OR 1. Bleeding 2. Evaporative losses in long open case 3. Excessive urinary loss 4. Increase in capacitance from anesthetic

What does volume do for DO 2? It increases cardiac output by increasing cardiac filling If the problem was not fixed you need to know if cardiac output increased If yes: give more volume If no: 1. Was enough volume given? OR 2. Is the patient not volume responsive and something else must be done

Fluid Challenge and volume responsiveness 1 Assess the value of Pra ( NOT the wedge). 2 Give sufficient fluid to raise Pra by ~2mmHg and observe Q. Q -ve +ve Increase in CVP tells me that I tested Starlings law Pra Type of fluid is not of importance if given fast enough

Change in CVP of even 1 mmhg should be sufficient to test the Starling response Q (l/min) plateau 5 Slope = 500 ml/mmhg/min 0 10 Pra (mmhg)

Assessment of cardiac output is the key element in a responsive approach Indirect: improvement of: BP, urine output, sensorium, skin perfusion, lactate, ScvO 2 (ie the trigger ) Direct measurement many non-invasive products available today but they vary in their accuracy of measurement

This should make it possible to now have flow-based Huge expansion protocols of for non-invasive fluid management devices and to to measure avoid over-use cardiac of output fluids. They are less precise than the PA catheter but have good accuracy ie can track trends

Accuracy vs Precision

Precision vs Accuracy Accuracy indicates similarity of measured value to to gold-standard Important when value is used as a trigger Precision indicates that the value is reproducible important when value is used for trending Accuracy is then not as important

729 Fluid Challenges > 30 % Potter et al J Crit Care 2012

The less invasive the device the less the precision High precision and accuracy: Pulmonary artery catheter, PiCO (thermodilution), LidCo plus (calibrated with lithium) Medium to high: esophageal Dopper Velocity and not flow and affected by diameter and angles The less ill the patient the less need for accuracy Only descending aorta -the trend is key Need to be intubated Medium to low: arterial waveform, plethysmographic Non-cardiac Sx pt do not need high accuracy flow is used to indicate the fluid response Low finger pulsation devices

Accuracy of 4 devices compared to PA catheter

Devices tested tracked changes very well (good precision) Pulse pressure based Plethysmographic based Zero slope indicates that the 2 devices tracked each other very well Pts post cardiac surgery PA catheter and low invasive devices 18 to 24 hr post surgery Received multiple interventions fluid boluses, NE, Epi, Dobutamine, Nitroprusside

Crit Care Med 2010 Vol. 38, No. 11 62% reduction in need for catecholamines the morning after surgery with use of colloid and no increase in renal injury or blood requirement

Targets CI < 2.2 or MAP < Target or SBP < Target or CVP < 3 No Yes R/O Low SVR or RV limitation Patient on Catecholamines? CI < 4 and CVP < 12? Yes No Yes Fluid Protocol Weaning Protocol Observe No Catecholamine Protocol

CI < 4 and CVP < 12? Yes Give Fluid Bolus Check CI and CVP CVP incr. > 2 and CI incr. < 0.3 Fluid Protocol CVP incr. < 2 YES This meant that a pt who and had an increase Yes in CVP CI incr. < 0.3 CVP incr. < 2 and CI incr. > 0.3 CVP incr. > 2 and CI incr. > 0.3 Inadequate challenge CI < 2.2 or MAP < 70 Cardiac or response SBP < Target ok or CVP <3 or UO < 20 Pt not volume responsive Review fluid criteria No No Saline Total Protocol Fluid >1L/24hr? from 2-4 mmhg and CI < 0.3 L/min/m 2 would not get further volume boluses Observe or wean Catecholamine Protocol

Conclusion Goal-directed therapy uses targets which have not been validated Can lead to excess treatment Currently no advantage over standard therapy A flow-directed responsive approach allows the clinician to follow the response to his/her clinical hypothesis Since the major role of volume therapy is to increase cardiac output it is important to know what happened to CO with the therapy

BP = Cardiac Output x SVR First Question to ask: Is the cardiac output decreased Or Is the cardiac output normal or increased Measured variable Cardiac output is the problem SVR is the problem

Fluid Challenge 1 Assess the value of Pra ( NOT the wedge). Q -ve 2 Give sufficient fluid to raise Pra by ~2mmHg and observe Q. +ve Pra Type of fluid is not of importance if given fast enough