OCTOPUS 300 Perimetry you can trust

Similar documents
OCTOPUS 600 See the new pulse in perimetry

OCTOPUS 900 Flexibility and reliability

OCTOPUS 900 Flexibility and reliability

3/16/2018. Perimetry

Description of new EyeSuite visual field and trend analysis functions

NEW AUTOMATED PERIMETERS NEW. Fast and precise perimetry at your fingertips. ZETA strategy EyeSee recording DPA analysis

VISUAL FIELDS. Visual Fields. Getting the Terminology Sorted Out 7/27/2018. Speaker: Michael Patrick Coleman, COT & ABOC

CHAPTER 6 SELECTING A TEST STRATEGY INTRODUCTION. accurate but shorter test may yield more useful visual

Expanding your field of vision. Visual Field Analyzers from Carl Zeiss

Hidden LED Array Perimeter IVS-201A / IVS-201B. Reliable Accurate Economical. Lis t ic

Visual Fields Shawn L. Cohen, M.D. Part 2 of 4. Definitions / Tables (Part 2 of 2) Static Perimetry (Humphrey, Octopus)

Perimetry Phobia: Don t fear the field Savory Turman, COMT, CPSS

21st Century Visual Field Testing

The Evolution of Fundus Perimetry

Diagnosing open-angle glaucoma may be particularly

PERIMETRY A STANDARD TEST IN OPHTHALMOLOGY

Financial Disclosure. Visual Field Interpretation RELIABILITY VISUAL FIELD INTERPRETATION IN GLAUCOMA METHODS OF DATA PRESENTATION

CHAPTER 11 KINETIC PERIMETRY WHAT IS KINETIC PERIMETRY? LIMITATIONS OF STATIC PERIMETRY LOW SPATIAL RESOLUTION

Introduction. Paulo de Tarso Ponte Pierre-Filho, 1 Rui Barroso Schimiti, 1 Jose Paulo Cabral de Vasconcellos 1 and Vital Paulino Costa 1,2

IPS Standards and Guidelines 2010

MOVE IT OR LOSE IT: THE ROLE OF KINETIC VISUAL FIELDS

CHAPTER 3 HOW TO PERFORM PERIMETRY YOU CAN TRUST

Definitions. Indications for Perimetry. Indications for Perimetry. Purposes of Perimetry. Indications for Perimetry 3/4/2015

CHAPTER 10 NON-CONVENTIONAL PERIMETRY

The ideal tool for early detection and monitoring of AMD.

STANDARD AUTOMATED PERIMETRY IS A GENERALLY

FORUM Glaucoma Workplace from ZEISS Clinical Interpretation Guide

CHAPTER 5 SELECTING A TEST PATTERN INTRODUCTION

C a t a r a c t G l a u c o m a R e t i n a R e f r a c t i v e. The GDxVCC Early answers and ongoing assessment for glaucoma

The New Frontier of Microperimetry

The New Frontier of Microperimetry

Investigative Ophthalmology & Vision Sciences MSc Course. Glaucoma Module. Visual Field Reliability Indices. David Henson 2014.

Science & Technologies

CHAPTER 13 CLINICAL CASES INTRODUCTION

Evolving glaucoma management True diagnostic integration for the preservation of vision

CORRELATING OF THE VISUAL FIELD INDEX WITH MEAN DEVIATION AND PATTERN STANDARD DEVIATION IN GLAUCOMA PATIENTS

Misleading Statistical Calculations in Faradvanced Glaucomatous Visual Field Loss

Characteristics of Frequency-of-Seeing Curves in Normal Subjects, Patients With Suspected Glaucoma, and Patients With Glaucoma

Quantification of Glaucomatous Visual Field Defects with Automated Perimetry

Exceptional versatility without compromise

International Journal Of Basic And Applied Physiology

Learn Connect Succeed. JCAHPO Regional Meetings 2017

Moving forward with a different perspective

Supplementary Appendix

Development of Visual Field Screening Procedures: A Case Study of the Octopus Perimeter

PRIMUS 200 from ZEISS The essential OCT

Citation for published version (APA): Stoutenbeek, R. (2010). Population based glaucoma screening Groningen: s.n.

COMPARISON BETWEEN THRESHOLD PUPIL PERIMETRY AND SUPRATHRESHOLD PUPIL PERIMETRY

Fluctuations on the Humphrey and Octopus Perimeters

(877) Progress Drive Front Royal, VA A Revolution in Scleral Lens Fitting

Access to the published version may require journal subscription. Published with permission from: Elsevier

Acto All together better for everyone

Reading centers are important in clinical trials to

boso ABI-system 100 Early detection of PAOD fast, precise, without Doppler Premium quality for doctors and hospitals

Correspondence should be addressed to Verena Prokosch;

RELIABLE CLASSIFICATION OF VISUAL FIELD DEFECTS IN AUTOMATED PERIMETRY USING CLUSTERING

Comparison of Visual Field Measurement with Heidelberg Edge Perimeter and Humphrey Visual Field Analyzer in Patients with Ocular Hypertension

IIH 1.0 L152~ L 33 IIIII_,. AI MICROCOPY RESOLUTION TEST CHARI JRFAU - A RDS-1963-A. doi

The Measure of Confidence

Macular Ganglion Cell Complex Measurement Using Spectral Domain Optical Coherence Tomography in Glaucoma

A new visual field test in empty sella syndrome: Rarebit perimetry

STRUCTURE & FUNCTION An Integrated Approach for the Detection and Follow-up of Glaucoma. Module 3a GDx

FLICKER-TOP PERIMETRY IN NORMALS AND PATIENTS WITH OCULAR HYPERTENSION AND EARLY GLAUCOMA

One intelligent solution

EasyScan: Smart Retinal Imaging

Early diagnosis of glaucoma

Glaucoma: Diagnostic Modalities

The intelligent solution. System One Sleep Therapy System uses advanced intelligence to deliver excellent care while making patient management easy

Linking structure and function in glaucoma

Test-retest variability in visual field testing using frequency doubling technology

ICS Impulse: Bringing diagnostic accuracy and efficiency into balance testing

New Concepts in Glaucoma Ben Gaddie, OD Moderator Murray Fingeret, OD Louis Pasquale, MD

Welch Allyn Cardiology Solutions

ATMOS 360 diagnostics. Complete solution.

tracking progression we can better manage our patients. Like any tool, any instrument you ve got to

IMAGE-GUIDED RADIATION THERAPY

T he retinal ganglion cells of different sizes have distinct

3/23/2016. Regina Smolyak, MD Glaucoma Service Flaum Eye Institute

Top Performance in Action. Never confuse movement with action Ernest Hemingway

EVALUATION OF FIXATION DURING PERIMETRY USING A NEW FUNDUS PERIMETER

PRIMUS 200 from ZEISS The essential OCT

Digital mammography imaging from Carestream Health solutions for great workflow, productivity, and patient care.

The Comprehensive Treatment Management System

myaudiometer. It s familiar, and it s so much

by Maico Diagnostics

One intelligent solution

Complex just became comfortable.

As with most body systems, there are vision changes that will occur for most of use these are typical or expected changes.

53 year old woman attends your practice for routine exam. She has no past medical history or family history of note.

Comparative study of new imaging technologies for the diagnosis of glaucoma: Protocol Approved by the Ethics Committee

Eye-tracking technology in low vision: implications for functional diagnosis and rehabilitation

The improvement in perimetric results occurring over

C linical visual field tests are designed to provide. Measurement error of visual field tests in glaucoma LABORATORY SCIENCE

Effective Treatment for Obstructive Sleep Apnoea

powerful versatile mobile

HFA3 with SITA Faster Frequently Asked Questions

Handheld OAE-Tympanometry Combination System

LOCSU Community Services. Glaucoma Repeat Readings & OHT Monitoring Community Service Pathway. Issued by Local Optical Committee Support Unit May 2009

Cirrus TM HD-OCT. Details define your decisions

Use of a portable head mounted perimetry system to assess bedside visual fields

Transcription:

OCTOPUS 300 Perimetry you can trust Tradition and innovation Since 1858, visionary thinking and a fascination with technology have guided us to develop innovative products of outstanding reliability: Anticipating trends to improve the quality of life.

02 03 PERIMETRY YOU CAN TRUST OCTOPUS 300 Central 30 degree perimeter In 1972 Franz Fankhauser and others developed the principles and concepts of automated perimetry which resulted in the design of the first automated static perimeter, the Octopus 201, in 1974. Since then, Octopus has pioneered many significant innovations like the G- pattern, the direct projection system, fast strategies and outstanding software for visual field analysis. Detecting visual field loss, defining the optimum treatment and following up the patient to decide on the necessity of treatment changes or surgery are the main tasks of every glaucoma specialist. Addressing the basic needs of a glaucoma specialist, the Octopus 300 is a central 30 degree perimeter for anyone who wants diagnostic flexibility for analyzing, assessing and tracking patients visual fields. With this device, you can run standard central fields with minimum test duration which are seamlessly integrated into your practice environment. This supports high patient throughput and effective practice management. With its built-in reliability features, the Octopus 300 is easy-to-use and delivers results you can trust. A wide range of commonly used static test patterns, including G, 32, 30-2, 24-2, M, and 10-2 are incorporated into the Octopus 300. Additionally, low vision programs for patients with advanced disease present stimuli at maximum stimulus brightness from the start and use an increased stimulus size. This not only saves valuable testing time, but also increases patient comfort. Furthermore, the Octopus 300 incorporates both Short-Wavelength Automated Perimetry (SWAP) and Flicker Perimetry for early glaucoma detection. Automated Eye Tracking (AET)* recognizes the position of the pupil and automatically adjusts the fixation target in case the pupil is not properly aligned.

Central field standard white-on-white perimetry The Octopus 300 performs standard white-on-white threshold testing in just 2 4 minutes in the central visual field. A wide range of commonly used static test patterns, including G, 32, 30-2, 24-2, M, and 10-2 are also incorporated into the Octopus 300. Reliable results made easy Worry less about patient compliance. The Octopus 300 automatically recognises fixation losses and adjusts patients accordingly until optimal test conditions are achieved. Thus, the Octopus 300 produces results you can trust.

04 05 ADVANCED ANALYSIS OCTOPUS 300 Central field standard white-on-white perimetry The Octopus 300 offers a wide range of static test patterns, including 32, 30-2, 24-2, and 10-2. In addition, there are two unique physiology-based patterns: the G-Program (a 30-degree field for glaucoma assessment) and the M-Program (a 10-degree field for analysing the macula). They are both correlated with a nerve fibre bundle map and thus make it possible to test the points which are most important for a structure-function correlation. These examination patterns offer a higher density of stimuli in the centre, which supports the discovery of paracentral scotomas that are often missed by the common 32 pattern. Additionally, low vision programs for patients with advanced disease present stimuli first at maximum stimulus brightness and use an increased stimulus size. This not only saves valuable testing time, but also increases patient comfort. Furthermore, the Octopus 300 incorporates both Short-Wavelength Automated Perimetry (SWAP) and Flicker Perimetry for early glaucoma detection.

TOP FAST-THRESHOLDING STRATEGY Increased efficiency Tendency Oriented Perimetry (TOP) presents a further optimisation in fastthreshold testing by reducing the examination time by nearly 80% to just 2 4 minutes 1,2 compared to 6 8 minutes (Dynamic strategy) or 10 12 minutes (Normal strategy). The TOP algorithm is a systematic method which takes the correlation of the threshold values in neighbouring locations into account. TIME COMPARISON BETWEEN TEST STRATEGIES Since the first test points are presented at a supra-threshold level, even inexperienced patients quickly understand the nature of the test. CLUSTER ANALYSIS Providing meaningful results Cluster analysis combines high sensitivity with good specificity 3. Test locations are grouped (clustered) along nerve fibre bundles, to better analyse changes in crucial areas such as the nasal step or the macula. This eliminates the time-consuming method of counting isolated points. A combined probability/deviation graph highlights pathological regions. CLUSTER ANALYSIS POLAR GRAPH Combining structure and function Combining the results of both structure and function (see picture: A) is key to obtaining a comprehensive assessment of the onset and progression of Glaucoma. With the Octopus Polar Graph, the nerve fibre bundles that are in danger or defective are easily identified. Local defects are projected along the nerve fibres to the optic disk and are represented as red lines (B). The projected defects (C, D) are vertically mirrored and scaled with rings for 10, 20 and 30 db deviation (E). The Octopus Polar Graph allows for direct comparison with structural (F) findings. 4 POLAR GRAPH

PROGRESSION ANALYSIS Immediately identify levels of change INTUITIVE TRAFFIC LIGHT SYMBOLS EyeSuite Perimetry software is included as standard, featuring the most advanced EyeSuite Progression Analysis for following up visual fields. As recommended by the International Glaucoma Society, the global progression rate is calculated in db per year, including the probability level. Areas for normal range (grey band), impaired vision (15 db) and legal blindness (25 db) provide a starting point for further investigation. Often, progression is local and not noticeable on global progression analysis. No more counting of single points and looking for clusters. EyeSuite does the work for you! The EyeSuite Cluster Trend Analysis is based on specific clusters of test points that are matched to the nerve fibre bundles, while the Polar Trend Analysis allows direct comparison with structural findings. With these two local progression analyses, even small local changes that are not visible at a global level can be easily detected and followed up 4,5. Intuitive colour codes save time by immediately identifying levels of change. A red triangle will always indicate significant worsening, a yellow diamond increased fluctuation and a green triangle significant improvement. EYESUITE CLUSTER TREND ANALYSIS VARIOUS PRINTOUTS Intuitive interpretation of visual field results Configure your favorite printout and graphics representation, in order to reduce the time necessary to interpret the results. Choose either the proven Octopus 7-in-1 printout containing the cumulative defect curve (Bebie curve) or the HFA-style printout. Furthermore, the 4-in-1 printout or the series report can also be customised. Don t want a paper copy? Save the report as an image or PDF and view it on your screen or export it to your electronic medical record (EMR) system. VARIOUS PRINTOUTS

Visual field evaluation is made simple with the widely-used Octopus 7-in-1 printout.

08 09 RESULTS YOU CAN TRUST Fixation control Reliable results made easy Fixation losses due to low patient compliance are a major reason for unreliable visual fields. The Octopus 300 gives you less reason to worry about these. Blink Control, Pupil Position Control, Automated Eye Tracking (AET) and Contact Control continously support the correct patient and eye position for a reliable result you can trust. BLINK CONTROL Never miss a point PAUSED RUNNING Normal blinking prevents dry eyes and helps the patient to relax and concentrate during examination. With Octopus Blink Control, you need never worry again about missing a stimulus presented in static perimetry. Stimuli interrupted by the patient s blinking are automatically repeated later during the test. This means that every test location is tested reliably. BLINK CONTROL PUPIL POSITION CONTROL Controlled position PAUSED RUNNING Maintaining the correct pupil position during examination is essential for correct identification of the location of a defect. If the pupil position changes during stimulus presentation, due either to shifiting of the head or eye movement, the Pupil Position Control pauses the examination automatically until the pupil is recentred. This stimulus is automatically repeated later during the test. The result is a visual field that you can trust. PUPIL POSITION CONTROL

RUNNING RUNNING AUTOMATED EYE TRACKING Minimise artefacts Positioning the pupil in the centre of the trial lens is essential to preventing lens rim and anatomical artefacts. Automated Eye Tracking (AET)* recognises the position of the pupil and automatically adjusts the fixation target in case the pupil is not properly aligned. Thus, the Octopus 300 provides optimum conditions for reliable and undelayed results. AUTOMATED EYE TRACKING PAUSED RUNNING CONTACT CONTROL Optimal patient position Head sensors offer even further control and reliability by constantly assessing the correct patient position. If the patient pulls away from the instrument, it immediately notifies the operator and pauses the test to allow for repositioning. CONTACT CONTROL *Automated Eye Tracking checks the location of the pupil, but not the gaze direction.

10 11 CONNECTIVITY IS KEY EyeSuite Platform Flexible interfaces for easy integration into your network The EyeSuite software is designed for optimum patient flows in busy practices. It is very easy to use, making the Octopus 300 fully networkable both with other Haag-Streit devices and your practice network. EyeSuite does not require any proprietary third-party software to provide connectivity. Furthermore, the EyeSuite Script Language or standardised interfaces, such as GDT or DICOM, connect easily to almost any electronic medical record (EMR) system. Patient orders can be received from the EMR system and the measured results are then automatically sent back to the EMR system. If the Octopus 300 is connected to an EyeSuite Server, all of its data can be accessed remotely from any number of viewing stations connected to the same database. This truly means going beyond a pre-defined printout and provides you with real-time access to your data from anywhere in your network. With all these features availabe, you can save valuable staff time and eliminate the risk of transcription errors.

Technical specifications Octopus 300 Stimulus generation Peripheral range (distance) Direct projection system 30 (infinite) Octopus 300 Basic Background illumination (asb) 31 31/314 Stimulus size (Goldmann) III, V Stimulus duration (ms) 100, 200, 500 Stimulus intensity (asb, dynamic range) Fixation control Networking Data Import 0.48 4800 (40 db) Blink Control, Pupil Position Control, AET (Automated Eye Tracking), Contact Control DICOM, EMR, Ethernet Octopus 101, 123, 600 and 900; HFA Measures (W x L x H) 450 mm x 530 mm x 560 mm; 17.7 x 20.9 x 22.0 Weight 22 kg; 49 lbs Octopus 300 Pro Test methods Standard white-on-white perimetry SAP Blue/yellow perimetry SWAP (Package Blue/Yellow Perimetry) Flicker perimetry for early diagnosis (Package Flicker Perimetry) Test strategies TOP (Tendency Oriented Perimetry, 2 4 min) Dynamic (adaptive step size, 6 8 min) Normal (4-2-1 bracketing, 10 12 min) Other (LV: Low Vision with Goldmann V; 2-LT: 2-Level Test, 1-LT: 1-Level Test) (Package TOP fast strategy) Test patterns General/Glaucoma 30 (G1-Program, 32) Macula (M-Program (10 /30 )) Screening (ST) Custom Tests (including 30-2, 10-2) (Package Custom Tests) Progression analysis Global progression (MD, slv) Cluster Trend/Polar Trend (Package Cluster/ Polar Trend) Included Optionally available Sources 1 King AJ, Taguri A, Wadood AC, Azuara-Blanco A. Comparison of two fast strategies, SITA Fast and TOP, for the assessment of visual fields in glaucoma patients. Graefes Arch Clin Exp Ophthalmol. 2002 Jun;240(6):481-7. 2 Wadood AC, Azuara-Blanco A, Aspinall P, Taguri A, King A. Sensitivity and specificity of frequency-doubling technology, tendencyoriented perimetry, and Humphrey Swedish interactive threshold algorithm-fast perimetry in a glaucoma practice.am J Ophthalmol. 2002 Mar;133(3):327-32. 3 Kovalska MP, Bürki E, Schoetzau A, Orguel SF, Orguel S, Grieshaber MC. Clinical evaluation of a novel population-based regression analysis for detecting glaucomatous visual field progression. Klin Monbl Augenheilkd. 2011 Apr;228(4):311-7. 4 Holló G, Naghizadeh F. Evaluation of Octopus Polar Trend Analysis for detection of glaucomatous progression. Eur J Ophthalmol. 2014 Jun. DOI: 10.5301/ejo.5000504. 5 Naghizadeh F, Holló G. Detection of early glaucomatous progression with Octopus Cluster Trend analysis. J Glaucoma. 2014 Jun-Jul;23(5):269-75.

HS-Art.No. 1511.7220457.02010 Members of HAAG-STREIT Group HAAG-STREIT Holding AG www.haag-streit-holding.com HAAG-STREIT Deutschland GmbH www.haag-streit.de HAAG-STREIT AG www.haag-streit.com IPRO GmbH www.ipro.com SPECTROS AG www.spectros.ch CLEMENT CLARKE Ltd. www.clement-clarke.com HAAG-STREIT Medtech AG www.haag-streit-medtech.com HAAG-STREIT UK www.haag-streit-uk.com HAAG-STREIT France EURL www.haag-streit.fr John Weiss Ltd. www.johnweiss.com HAAG-STREIT Far East www.haag-streit-fareast.com HAAG-STREIT USA www.haag-streit-usa.com HAAG-STREIT AG Gartenstadtstrasse 10 3098 Koeniz Switzerland Phone +41 31 978 01 11 Fax +41 31 978 02 82 info@haag-streit.com www.haag-streit.com HAAG-STREIT Surgical GmbH www.haag-streit-surgical.com Möller-Wedel GmbH & Co KG www.moeller-wedel.com Möller-Wedel Optical GmbH www.moeller-wedel-optical.com Reliance Medical Inc. www.haag-streit-usa.com Asetronics AG www.asetronics.ch ComLab AG www.comlab.ch HAAG-STREIT AG, 3098 Koeniz, Switzerland 1. Edition/2014 06