Radiation Doses in Radiology: Influence of Standards and Regulations

Similar documents
Dose Estimates for Nuclear Medicine Procedures: What are they? Where do they come from?

Recent Progress in Radiation Dosimetry for Epidemiology and Radiological Protection. John Harrison ICRP Committee 2

Managing the imaging dose during Image-guided Radiotherapy. Martin J Murphy PhD Department of Radiation Oncology Virginia Commonwealth University

CT Radiation Risks and Dose Reduction

Background Radiation in U.S. ~ msv/yr msv/yr ~0.02 ~0.02 msv msv/day /day (~2 m rem/day) mrem/day) NCRP 4

Dosimetric Consideration in Diagnostic Radiology

Why is CT Dose of Interest?

Twelfth Annual Warren K. Sinclair Keynote Address

3 rd International Symposium on the System of Radiological Protection Seoul, October John Harrison

Utilize radiation safety principles to reduce the amount of radiation used to achieve desired clinical result.

Accounting for Imaging Dose

Radiation Safety in the Catheterization Lab

CT Dose Estimation. John M. Boone, Ph.D., FAAPM, FSBI, FACR Professor and Vice Chair of Radiology. University of California Davis Medical Center

Radiation Dose Specification

ICRP Recommendations Evolution or Revolution? John R Cooper Main Commission

Review of the Radiobiological Principles of Radiation Protection

PHY138Y Nuclear and Radiation

GUIDELINES ON IONISING RADIATION DOSE LIMITS AND ANNUAL LIMITS ON INTAKE OF RADIOACTIVE MATERIAL

Outline. NCRP Scientific Committee 6-2

Tracking Doses in the Pediatric Population

Ionizing Radiation Exposure of the Population of the United States. David A. Schauer Executive Director

Why radiation protection matters?

Further there has been shift from equipment focus to patient focus. During the last 15 years QC testing of equipment and dosimetry in phantoms

Measurement of organ dose in abdomen-pelvis CT exam as a function of ma, KV and scanner type by Monte Carlo method

PERSONNEL MONITORING AND DOSIMETRY POLICIES

Radiation Protection- Cath lab

The Management of Imaging Procedure Dose Nuclear Medicine Dose Indices

Lab & Rad Safety Newsletter

created by high-voltage devices Examples include medical and dental x-rays, light, microwaves and nuclear energy

Radiation Safety for New Medical Physics Graduate Students

Development of Computational Code for Internal Dosimetry

Measurement of Kidneys Dose in Three Hospitals during Chest and Abdomen Radiographic Examinations


Radiation Units and Dosimetry 15 August Kalpana M. Kanal, Ph.D., DABR 1

APPENDIX G - Organ/Tissue Weighting Factors and Detriment/Risk Coefficients

Radiation Protection Program Update: The Details. July 2010

Standardization of Radiopharmaceutical Dosimetry

ICRP Symposium on the International System of Radiological Protection

Managing the imaging dose during image-guided radiation therapy

Managing Patient Dose in Computed Tomography (CT)

Managing Patient Dose in Computed Tomography (CT) INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION

Population Dose from General X-ray and Nuclear Medicine: 2010

RPR 48B. APPLICATION TO USE DIAGNOSTIC EXTERNAL RADIATION IN HUMAN RESEARCH STUDIES

RAMPS-GNYCHPS 2010 Spring Symposium New York, NY, April 30, Error Prevention and Patient Safety for Radiation Treatment and Diagnosis

An Assessment of Organ and Effective Dose of Patients who Undertake CT Examinations in two Teaching Hospitals of Mashhad&Isfahan

Radiation related cancer risk & benefit/risk assessment for screening procedures

Medical Fluoroscopic Exposures and Incidents

Assessment of effective dose in paediatric CT examinations

JHM-IRB Guidelines for Radiation Statements

Learning Objectives. Review of the Radiobiological Principles of Radiation Protection. Radiation Effects

DETERMINATION OF ENTRANCE SKIN DOSE FROM DIAGNOSTIC X-RAY OF HUMAN CHEST AT FEDERAL MEDICAL CENTRE KEFFI, NIGERIA

Organ Dose Variability with Gender, Age and BMI

Krueger-Gilbert Health Physics, Inc.

NONE. Disclosures. Accreditation Update

AAPM Annual Meeting. ACR Accreditation Update in CT

Prepublication Requirements

Krueger Gilbert Health Physics, Inc.

Debra Pennington, MD Director of Imaging Dell Children s Medical Center

Prof. Dr. Doğan BOR Ankara University Institute of Nuclear Science

Dosimetry in Medical Exposures: Trends, Challenges and Next Steps

ALTERNATIVES TO THE EFFECTIVE DOSE FOR STOCHASTIC RISK ASSESSMENT IN MEDICAL IMAGING

NCRP Overview Program Area Committee 4 Radiation Protection in Medicine

Radiation Dosimetry for CT Protocols

Invivo Dosimetry for Mammography with and without Lead Apron Using the Glass Dosimeters

The Basics of Radiation Safety

ICRP RECOMMENDATIONS AND IAEA SAFETY STANDARDS: THEN AND NOW

Radiologic Units: What You Need to Know

Radiopharmaceuticals. Radionuclides in NM. Radionuclides NUCLEAR MEDICINE. Modes of radioactive decays DIAGNOSTIC THERAPY CHEMICAL COMPOUND

Radiation Safety Information for Students in Courses given by the Nuclear Physics Group at KTH, Stockholm, Sweden

Radiation Safety Guide. Analytical X-Ray Equipment

STUDIES OF LOW-DOSE RADIATION AND CANCER. E. Lubin

Medical Events. Florida Department of Health Division of Emergency Preparedness and Community Support Bureau of Radiation Control

Dosimetry of recently introduced CBCT Units for Oral and Maxillofacial Radiology

Radiation Quantities and Units

PRINCIPLES AND METHODS OF RADIATION PROTECTION

Colour on-line figures None Colour print figures None

BEIR VII: Epidemiology and Models for Estimating Cancer Risk

Summary of Patient Release after Radioiodine Therapy Research Review

Section 7 ALARA Program

A Real-Time Monte Carlo System for Internal Dose Evaluation Using an Anthropomorphic Phantom with Different Shapes of Tumors Inserted

STANDARDIZED RADIOGENIC CANCER RISK COEFFICIENTS: A REVIEW OF THE METHODOLOGY PRESENTED IN FEDERAL GUIDANCE REPORT NO. 13

Sodium Iodide I 131 Solution. Click Here to Continue. Click Here to Return to Table of Contents

NCRP PAC 4: Radiation Protection in Medicine. Overview. NCRP and PAC 4. Donald L. Miller, MD FSIR FACR Center for Devices and Radiological Health FDA

Radiation Dose Rates from Patients Administrated Radiopharmaceuticals Used for Brain Blood Flow Investigation.

People Exposed to More Radiation from Medical Exams

The New Jersey Radiographic Quality Assurance Program at 5 Years

Diagnostic Reference Levels (DRLs)

Radiation Dose in Pediatric Imaging

Re: PSM of the National Voluntary Consensus Standard for Patient Safety Measures, 2 nd Report

Radiation Dose To Pediatric Patients in Computed Tomography in Sudan

PATIENT ENTRANCE SKIN DOSES AT MINNA AND IBADAN FOR COMMON DIAGNOSTIC RADIOLOGICAL EXAMINATIONS

Biological Effects of Ionizing Radiation Module 8 - AAPM/RSNA Curriculum. Basic Radiation Biology

Facing the challenges: IAEA activities to protect the patients

Radiation Protection in Laboratory work. Mats Isaksson, prof. Department of radiation physics, GU

Radiological Protection Countermeasures after TEPCO Fukushima NPP Accident -Who should play the role of risk communication-

ICRP = International Commission on. recommendations and guidance on. Functioning since 1928.

Agenda: Dental Cone Beam Imaging

Radiation Dose in X-Ray and CT Exams

Justification, Optimization and Communication in Pediatric CT Imaging: Recent Improvements and Persistent Challenges Designated Emphasis in Nuclear

Australian Per Caput Doses from Diagnostic Imaging and Nuclear Medicine

Transcription:

Radiation Doses in Radiology: Influence of Standards and Regulations Beebe Symposium National Academy of Sciences December 9, 2009 Washington D.C. Orhan H Suleiman MS PhD, FAAPM Senior Science Policy Adviser Office of Oncology Drug Products Office of New Drugs Orhan.Suleiman@fda.hhs.gov 1

Disclaimer statement The opinions expressed in this presentation may not necessarily reflect the official position of the Food and Drug Administration or the Department of Health and Human Services. 2

The critical path towards mandatory standards (regulation) Education - professional forums, publications.. Consensus for Good Practice Voluntary Standards Mandatory Standards (Regulations) Enforcement. Litigation (regulator of last resort). 3

Many ways to educate and regulate via standards Reimbursement standards Centers for Medicare and Medicaid Services (CMS)- reasonable and customary Insurance Companies Product Standards Food and Drug Administration (FDA)- safety and efficacy Testing Laboratories Professional standards Licensing/ Registration (States) Certification (Professional Boards) Accreditation Joint Commission on the Accreditation of Healthcare Organizations (JCAHO) American College of Radiology (ACR) 4

Standards and Regulations on Medical radiation dose Historically, controlling or limiting patient radiation dose was interpreted as interfering with the practice of medicine, but that has changed. What is a high dose? know it when we see it... paraphrasing Supreme Court Justice Potter Stewart. What is a reasonable dose? 5

As low as reasonably achievable (ALARA) If ALARA were followed, especially in medicine the question of high dose would be mute. The highest doses are in therapy, yet we rarely need to question these values, other than the accuracy of the radiation dose. So high or low is relative to the imaging and medical task. 6

Mammography In the next few slides I will discuss mammography as a comprehensive example. education, a general consensus as to good practice, voluntary standards, and finally regulatory (Mandatory) Standards, with the Mammography Quality Standards Act of 1992 (MQSA). 7

Mammography Dose Metrics 47 Roentgen- entrance skin exposure (74) 14 mgy mean glandular dose (74) 3 mgy limit for standard phantom (85/92) 1.8 mgy (2009) Mean glandular dose is the standard dosimetric quantity in mammography. 8

Dose and Image Quality Trends in Mammography 16 14 Mean Glandular Dose Phantom Score (w/o artifact subtraction) 13 12 12 11 Dose (mgy) 10 8 6 10 9 8 Phantom Score 4 7 2 6 0 1970 1975 1980 1985 1990 1995 2000 2005 Year 5 9

The Standard FDA, ACR Mammography Phantom (~4.2 cm compressed breast) 10

Standard phantom image used to assess optimal performance of entire imaging chain, over time. 11

Nationwide Evaluation of X-ray Trends (NEXT) Collaborative program where periodic surveys are conducted to determine radiation associated for a set of widely used exams (mammography, chest, abdomen, fluoroscopy, CT, pediatric). 1985 mammography survey conducted as a Nationwide Evaluation of X-ray Trends (NEXT) survey. Program uses standard, patient equivalent phantoms. 12

Phantoms used in the Nationwide Evaluation of X-ray Trends (NEXT) survey program Fluoroscopy CT Head phantom 13

Standardization was essential for NEXT Primarily a scientific exercise, establishing baseline data to demonstrate program efficacy over time. Measured air kerma (Entrance Skin Exposure) for several diagnostic x-ray exams. Also measured some simple metrics related to image quality. Phantoms equivalence to average patient was logical, but required some extra effort. We did not calculate organ doses, but organ doses could be calculated from these measurements. 14

Reference Levels as standards NEXT data generated distribution of exposures State of Illinois and CRCPD* - Exposure limits Presidential Directive (Carter)- 1978 Exposure Limits for Federal Facilities ICRP 26 (1977) - Reference, investigation, intervention levels - not limits! ACR 2008 Diagnostic Reference Levels Exam specific action level for follow-up investigation, usually the 75 th percentile. Not intended as a mandatory dose limit. *Conference of Radiation Control Program Directors 15

Nuclear Medicine Organ dose standardization It was the SNM* s Medical Internal Radiation Dose (MIRD) committee and the Oak Ridge National Laboratories that made the calculation of radiation organ doses a reality,.. This concept is the basis for radiation risk assessment today. *Society of Nuclear Medicine 16

Monte Carlo Computer Models Enabled the calculation of organ doses for a standard 70 kg human model from input data such as radioactivity and biodistribution for a specific radionuclide; later adopted for external x-ray sources. 17

Early standard reference mathematical models- 1969- Medical Internal Radiation Dosimetry (MIRD) Committee- nuclear medicine organ doses using standard reference phantom with organs (Snyder et al) 1975- This model modified for external x-ray beam sources (FDA- Rosenstein) German GSF- 1982 (Kramer et al) Concept of voxel phantoms British NRPB- 1985 (Jones et al).. mathematical, realistic, stylistic, dynamic, computational models.icrp Pub 110 (Apr 2009). 18

Many standard reference models. Consortium of Computational Human Phantoms website: http://www.virtualphantoms.org/ 19

These phantoms represent different ages, sizes, they may have scalable organ dimensions, different body geometries (prone, supine, upright, and some are dynamic (respiratory or cardiac cycles). 20

Adult Reference Computational Phantoms ICRP Publication 110: Adult Reference Computational Phantoms: Annals of the ICPR Volume 39 Issue 2 (International Commission on Radiological Protection) Phantoms based on medical images of real people, organ masses adjusted to ICRP (Pub 89-2002) adult Reference Male and Reference Female. Organ doses can now be calculated from all sources! 21

Science caused changes in regulatory concepts In the 70 s.as we developed the ability to calculate organ specific radiation absorbed dose, regulatory concepts shifted away from the (1) whole body dose to (2) organ/tissue doses. One legacy example of this two tier system which still exists today, promulgated in 1975, is FDA s radioactive drug research program.. 22

Radioactive Drug Research Committee Radiation Dose Limits* Organ or System Single Dose Annual and Total Dose Whole body 0.03 Sv (3 Rem) 0.05 Sv (5Rem) Active blood-forming organs 0.03 Sv (3 Rem) 0.05 Sv (5 Rem) Lens of the eye 0.03 Sv (3 Rem) 0.05 Sv (5 Rem) Gonads 0.03 Sv (3 Rem) 0.05 Sv (5 Rem) Other organs 0.05 Sv (5 Rem) 0.15 Sv (15 Rem) Based on 1975 Nuclear Regulatory Commission s occupational dose limits *21 CFR 361.1 (b) (3) Radiation doses from x-ray procedures that are part of the research study shall also be included. For research subjects under 18 years of age at his last birthday, the radiation dose does not exceed 10 percent of adult dose. 23

This disparity between whole body and organ dose limits was finally addressed by the International Commission on Radiological Protection (ICRP) in 1977!...32 years ago. 24

ICRP s dose and phantom standards. 1977 - ICRP (Report 26) introduced effective dose equivalent, H. 1990 - modified in Report 60 to effective dose, E. 2008 - E updated in Report 103. 2009 - Publication 110 Adult Reference Computational Phantoms 25

Effective Dose* (E) Risk based metric, relating partial body irradiations (individual organ or tissue, limited x-ray field) to uniform whole body irradiation. The effective dose (E) is the sum of the weighted equivalent doses in all the tissues and organs of the body. E= Σ T W T H T Where: W T is the weighting factor for tissue T, and H T is the individual tissue or organ dose for tissue T *International Commission on Radiological Protection (ICRP Report 60, 1990) 26

Effective Dose, a Worldwide standard Advantages Allows comparison of radiation dose (detriment) from different sources Single metric Limitations Single metric, creates potential for people to ignore underlying organ doses, which are important for medicine and specific safety situations. Ignores age and gender, so comparisons between populations of different age and gender is problematic It is a radiation protection metric, not rigorously scientific, not originally designed for medicine. 27

Tissue Weighting Factors (w t ) Organ (Tissue) Reports: 26 60 DRAFT/103 Gonads Breast Red BM, lung Thyroid Bone surfaces Colon, stomach (NC- not calculated) Bladder, liver, esophagus Skin Salivary glands, brain Remainder Total 0.25 0.15 0.12 0.03 0.03 NC NC NC NC 0.30 1.00 0.20 0.05 0.12 0.05 0.01 0.12 0.05 0.01 NC 0.05 1.00 0.05/0.08 0.12 0.12 0.05/0.04 0.01 0.12 0.05/0.04 0.01 0.01 0.10/0.12 1.00 28

These periodic changes in Tissue Weighting Factors (w t ) are important! Demonstrate that new science is being incorporated periodically. 29

Effective dose, E, allows comparison among modalities The only standard risk based metric that allows comparison of radiation dose from different sources such as x-ray, CT, nuclear medicine, and other sources. The next slide, although not perfect, uses E, and compares the average dose, when known, or typical doses for a variety of exams or sources. Caveat - even for a known amount of radiation, the dose any individual may receive can vary by a factor of 10 or more for a variety of reasons, such as patient size, geometry, radiation type and quality, and time. 30

Typical Doses - Adults (E) Radiation Effective Equivalent to Equivalent Lifetime* Source Dose (E) # of chest x-rays time Cancer Mortality Risk Background U.S. - 1 year 3 msv 150 1 year 1.5 10-4 Medical Chest x-ray 0.02 msv 1 2.4 days 1.0 10-6 Upper GI fl 3 msv 150 1 year 1.5 10-4 CT- abdomen 10 msv 500 3.3 years 5.0 10-4 Tc-99m-lung perf 1 msv 50 4 months 5.0 10-5 Tc-99m-bone 4 msv 200 1.3 years 2.0 10-4 PET FDG 10 msv 500 3.3 years 5.0 10-4 Regulatory Limits Individual Gen pop 1 msv 50 4 months 5.0 10-5 Worker 50 msv 2500 16.7 years 2.5 10-3 Emergency Worker 500 msv 25,000 167 years 2.5 10-2 *ICRP 60 risk coefficients 31

Effective dose, E, despite limitations, is a valuable dose standard. A better metric would also adjust each organ dose for age, sex, and dose rate. These could be addressed in the future. 32

Effective dose, E, has not been adopted in a timely, standard manner! 1975 FDA s RDRC* Dose limits- rem 1977 ICRP* promulgates effective dose equivalent, H. 1980 s R to air kerma, rad to Gy; rem to Sv; mci to MBq. 1991 NRC** adopts H for radiation dose 1991 ICRP replaces H with effective dose, E 1993 NCRP*** adopts E. 2008 ICRP adopts new w t s. 2009 NRC considers adopting E *Radioactive Drug Research Committee (CFR 21 361.1) *International Commission on Radiological Protection **Nuclear Regulatory Commission *** National Council on Radiation Protection and Measurements 33

When should voluntary standards be mandated? Safety, avoidance of harm, is usually a major justification for such mandatory regulatory standards. Often mandated by legal statute. When voluntary standards have failed to prevent harm. 34

For fluoroscopy When we still observe deterministic effects such as skin erythema and radiation burns, it is obvious education alone is not working. 35

Fluoroscopy regulatory history Professional articles ACR/FDA Fluoroscopy Workshop- 1992 ACR/FDA Fluoroscopy Conference held in Reston, VA (October 16 and 17, 1992) Two FDA Advisories (1994 and 1995) Dose speedometer and odometer regulations (June 2006) 21 CFR 1020 Sentinel Incident- JCAHO Yet radiation burns continue.. 36

And in Computed Tomography We are also observing deterministic effects such as skin erythema (ring around the body) and hair loss. Stochastic risks are not trivial, but they represent an abstract level of risk, but deterministic effects are palpable. 37

Computed Tomography regulatory history Professional articles, meetings, workshops FDA Advisories 2001, 2009 Voluntary Dose indicators Obviously with increasing use, we are observing more adverse events. 38

Are we repeating history? Major radiation epidemiologic studies have been medical, except for the LSS Life Span Study of A-Bomb Survivors (n = 91,228) Ankylosing Spondylitis (n = 14,106) Women treated for Cervical cancer (n~150,000) Canadian Fluoroscopy Study (n= 31,710) New York State Postpartum Mastitis Study (n = 601) Massachusetts Fluoroscopy Study (n = 1742) 39

What do these technologies have in common? Widely used, user friendly, and valuable medical technologies. Complex technologies, radiation source and anatomy change dynamically. Lack simple relationship between air kerma and absorbed dose. Dosimetry is challenging. Very operator (user) dependent. Potential to deliver deterministic adverse events. 40

Radiation Safety Assurance Operators must understand radiation safety for their modality, not just how to operate it. Current equipment dose displays insufficient for safety, we need a standardized radiation dose to patient display, for all modalities. 41

Radiation Source Metrics Essential for dose calculation, but they are modality specific, radioactivity for nuclear medicine, air kerma, and air kerma rate for fluoroscopy, and CTDI for CT. These radiation source metrics are not a precise nor an accurate predictor of the final human radiation dose. Additional factors that will affect the final patient dose estimate are exposure time, patient size, and the specific protocol used. *Computed tomography dose index 42

So in order to practice As low as reasonably achievable (ALARA) You need to know the patient s dose? E, or something similar, representing the dose estimate to the patient, or a computational phantom of similar size, should be the standard for safety. Without E, how can you compare radiation risk among modalities? Cardiac imaging is an excellent example where the doses patients receive are not reported in a standard, comparable way. Which cardiac imaging study gives the most dose, fluoroscopic angiography, cardiac uptake studies using Tc-99m, or CTA (CT angiography), an 43 emerging cardiac imaging exam!

E can be determined for all modalities. The technology exists today to be part of the solution. For each modality using a specified technique or protocol, the dose to a set of phantom(s) representing different patient sizes can be calculated. This data could be stored in a database. For any patient using the same specified technique or protocol, the radiation dose can be estimated by matching the patient s dimensions with the computational phantom. A dose estimate, such as E, can be displayed in real time. These dose estimates (organ and E) would enable recording of this information in a standard way in a patient s permanent medical record. 44

And for the user (operator) We need to assure that the individuals using these technologies are educated and trained in standard radiation safety practice, specific to these technologies Variety of regulatory pathways exist to ensure standard education and training. 45

In closing (1) Today, when medically necessary, the radiation associated with any imaging modality that is properly operated and used is safe. The radiation dose for each new exam or protocol should always be estimated by qualified personnel. Repeat and multiple exams need to be tracked by recording the dose in a patient s medical record, since patients may often have additional exams. 46

In closing (2) Standard dose estimates for these exams, derived from organ doses should be determined for each patient. A whole body dose surrogate, such as E, should be displayed, which can also be recorded for each patient. Mandatory standards for patient radiation safety, for those individuals operating imaging modalities capable of delivering deterministic doses, should be required. 47

FDA 10903 New Hampshire Ave Silver Spring, Maryland 20993 48