Effect of Diode Laser 810nm in Hardness of Dental Ceramic

Similar documents
Acknowledgments Introduction p. 1 Objectives p. 1 Goals p. 2 History of Dental Materials p. 3 The Oral Environment p. 4 Characteristics of the Ideal

The Facts About Fillings

COURSE CURRICULUM FOR AESTHETIC DENTISTRY

The Facts About Fillings

The Facts About Fillings

All Ceramic Inlays - Coming of Age

Danville Family Dentist Dental Practice of Shailaja Singh DDS

Dentistry Ceramic materials

EMDOLA Education Program: First Year Details. History of lasers: Optics data : The quantum nature of the light:

riva helping you help your patients

Empress * CAD IPS. Confidence. Reliability. Esthetics. IPS Empress CAD for the CAD/CAM Technology Information for Dentists

Dentium Workflow Solution for Labs

Product Information. Translucent Zirconium Dioxide For monolithic restorations. Giving a hand to oral health.

DENT211-FIXED PROSTHODONTICS Page 1 Lecture: High Strength Ceramics INTRODUCTION

Power & Versatility in a Small, Portable Package

Competence in. All-Ceramics

Biocompatible materials

Lava Ceram. Overlay Porcelain for Lava Frameworks

This PDF is available for free download from a site hosted by Medknow Publications

The Future of Dentistry Now in Your Hands Changes everything you know about traditional Composites, Glass Ionomers and RMGIs

The Dental Board of California - Dental Materials Fact Sheet Adopted by the Board on October 17, 2001

Self-Adhesive (SA) Cement VS Dual-Cured (DC) Resin Cement

Glass Ionomers. Reputable, Durable, Long Lasting

Chapter 2 Biomaterials

RELATIONSHIPS MATTER. Innovation, Expertise and. Craftsmanship. in Laboratory. Products and. Services for the. Dental Profession

3D Printing Technology ----Applications in Dentistry

CONTINUING DENTAL EDUCATION University of Minnesota School of Dentistry. New Materials, Technologies & Laser Training October 13-15, 2017

5Recommended Shade-Matching Protocol

Restoration of the worn dentition

Fluorescent Properties of Porcelain-Restored Teeth and Their Discrimination

SHOFU BLOCK & DISK CAD/CAM CERAMIC-BASED RESTORATIVE. Visit or call mm x 14mm

and get a Pentamix TM Lite free *

Up to date literature at your disposal to discover the benefits of laser dentistry

Continually Fluoride Releasing Aesthetic Dental Restorative Material

The Dental Board of California Dental Materials Fact Sheet Adopted by the Board on October 17, 2001

NobelProcera Product Overview

SpeedCEM Plus. The self-adhesive resin cement A BIG PLUS FOR ZIRCONIA. Ideal for. ZirCAD

Operative dentistry. Lec: 10. Zinc oxide eugenol (ZOE):

LASERS FOR DENTAL APPLICATIONS.

Every shade a masterpiece. Lava Ceram. Zirconium oxide veneer ceramic for natural aesthetics

SHOFU BLOCK & DISK CAD/CAM CERAMIC-BASED RESTORATIVE. Visit or call mm x 12mm x 16mm. 98mm x 14mm. 12mm x 14mm x 18mm

SOLASE DENTAL DIODE LASER

VITA VMK Master Quickstart Instructions

Practicing Minimally Invasive Dentistry with Durability and Esthetic in Mind

FASTDESIGN. System. Same-Day Dentistry has never been this easy and affordable. Technologies, Inc. INTRODUCING THE

ACCREDITATION STANDARDS FOR DENTAL LABORATORY TECHNOLOGY EDUCATION PROGRAMS Frequency of Citings Based on Required Areas of Compliance

TECHNICAL GUIDE. For use with CEREC

Howard E. Strassler, DMD University of Maryland School of Dentistry

Photoluminescence spectra of sound tooth and those of different carious stages

Chapter 5. Investigation of in vitro Dental Erosion by Optical Techniques

You design, we create.

IPS Empress System Information for the. Laboratory. Confidence. Reliability. Esthetics. Empress IPS. System. The ultimate esthetic restorative system

Research Article Comparative Analysis of Color Parameters of Two Core Materials: Effect of Repeated Firings, Porcelain Thickness and Shade

CAD/CAM PREPARATION GUIDELINES & TISSUE MANAGEMENT TECHNIQUES RECOMMENDATIONS FOR OPTIMAL SCANNING, DESIGNING, AND MILLING

Calibra. Cements. The Simple Choice for Easy Cleanup

Optical properties of bovine dentin when irradiated by Nd:YAG and a black dentifrice aimed at treating dentin erosion

all ceramic all options The compact milling system Zenostar Telio CAD for Zenotec Your entrance into the digital world

Empress *CAD. Confidence. Reliability. Esthetics. IPS Empress CAD for the CAD/CAM Technology Information for Dentists

THE ONE AND ONLY. CLEARFIL Universal Bond

New Materials, Technologies & Laser Training Friday-Sunday, April 26-28, 2019

Chapter 12. Prosthodontics

EASY TO REMOVE HARD TO FORGET! PANAVIA SA Cement Plus Automix

Anterior Esthetic Techniques & Materials

You just get more with

Keep. simple. 3M RelyX Cements

Layering Guide for Labs. Lava Ceram. Overlay Porcelain for Lava Zirconia. Esthetic Restorations that are Truly Masterpieces

Posterior Adhesive Dentistry

Dental Ceramics: Material Options and Clinical Recommendations

Ketac Universal Aplicap

Near-UV light detection

SMILE DESIGNING. In a wide smile do your teeth show visible difference in their colour?

Where innovation meets indication GRADIA PLUS. from GC. 1 Modular composite system. for indirect restorations

TOOTH PREPARATION. (Boucher's Clinical Dental Terminology, 4th ed, p239)

Jordan University of Science and Technology Faculty of Applied Medical Sciences Department of Applied Dental Sciences First Semester Course syllabus

COMPUTER AIDED OVERPRESS - A SIMPLE PROCESS

Wirobond C+ Processing information for CAD/CAM-produced restorations. Partners in Progress

PG Cert Contemporary Tooth Preparations and Operative Dentistry

Available online at ScienceDirect. Procedia Engineering 114 (2015 ) st International Conference on Structural Integrity

TECHNICAL GUIDE KATANA ZIRCONIA MULTI-LAYERED SERIES

Press Impulse. In pursuit of nature. all ceramic all you need

Outline: Laser sources Laser safety Laser (dental) material interactions. Laser applications in dentistry Summary

Nexco. Lifelike appearance. made easy. The light-curing lab composite

SOLASE DENTAL DIODE LASER

DPI Luting Cement. DPI Restorative Cement

dental fillings facts About the brochure:

Find Decay. Features. on any surface... Restorations! even around

IPS. Empress Esthetic. NEWS from the IPS Empress Original System

The Uses of Laser-Induced Fluorescence to Distinguish between Dental Caries and Sound Tooth

Occlusion and Attachments

lec: Dental material dr. Aseel Mohammed Filling material

Bonding to dentine: How it works. The future of restorative dentistry

The key to exceptional craft lies in exceptional materials.

Ceramic Based Aesthetic CAD/CAM Restorative

guidelines Clinical guidelines crown work Smile... first impressions last

Integration of New Technology. Change

SPACE MAINTAINER. Multimedia Health Education. Disclaimer

The all-rounder for hard tissue and soft tissue The new elexxion delos 4.0

Types of prostetic appliances Dr. Barbara Kispélyi

My Lava Ultimate. Chairside Crown. Lava Ultimate CAD/CAM Restorative for CEREC. Precision Solutions

General Properties of Dental Materials Physical properties: 1-Color Translucence

Transcription:

Optics and Photonics Journal, 2014, 4, 104-112 Published Online May 2014 in SciRes. http://www.scirp.org/journal/opj http://dx.doi.org/10.4236/opj.2014.45011 Effect of Diode Laser 810nm in Hardness of Dental Ceramic Mubarak M. Ahmed 1,2, Abdelaziz Hagar Abdelrahman 1,2*, Elhadi Mohieldin 3, Samia Omer Yagoub 1 1 Laser system Department, Laser Institute, Sudan University of Science and Technology, Khartoum, Sudan 2 Department of Physics, Faculty of Science and Arts at Al-Muznib, Qassim University, Al-Muznib, KSA 3 Restorative Dentistry, Faculty of Dentistry, University of Medical Science and Technology, Khartoum, Sudan Email: * ahay20004@yahoo.com Received 20 March 2014; revised 21 April 2014; accepted 18 May 2014 Copyright 2014 by authors and Scientific Research Publishing Inc. This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/ Abstract This research studied the effect of diode laser (810 nm), with various power (30, 200, 500) mw in hardness of the material used in the combinations of teeth (ceramics). Hardness was measured for dental ceramic samples divided into four groups, each group containing ten test samples, before and after it irradiated with the diode laser with wavelength 810 nm and different power (30, 200, 500) mw, with irradiation power of 200 mw for duration two minutes and ten minutes to the third and fourth groups, and irradiation power of 30 and 500 mw for duration one minute for the last two groups. The results showed that the increase in the irradiated time of the samples from two minutes to ten minutes, as well as increased power from 30 to 500 mw does not have a significant effect in increasing the hardness of the ceramic material. This study found that the hardness ratio of the samples was increased up to (18.28%), by irradiation of invisible diode laser 810 nm, 30 mw. Keywords Dental Ceramic, Invisible Laser, Irradiation, Hardness 1. Introduction The laser now plays an important role in our everyday life. It has a wide variety of applications in industry, engineering and medicine [1] [2]. Therefore, it is not surprising to find many papers dealing with irradiation power in lasers applications [3]. Dental ceramics or porcelain is popular due to the demand for aesthetics and durability * Corresponding author. How to cite this paper: Ahmed, M.M., et al. (2014) Effect of Diode Laser 810nm in Hardness of Dental Ceramic. Optics and Photonics Journal, 4, 104-112. http://dx.doi.org/10.4236/opj.2014.45011

of restoration. Dental ceramics consist of mainly glass, porcelain or crystalline of structure, the physical or mechanical properties of ceramic are much closer to enamel than those of acrylic resins and method, ceramic also have a coefficient of thermal expansion very close to that of teeth [4]. Dental ceramics contain a crystal phase and a glass phase based on the silica structure, containing central Si 4+ ion with four O ions. It is not closely packed, having both covalent and ionic characteristics. The usual dental ceramic, is glassy in nature, with short-range crystallinity. The only true crystalline ceramic used at present in restorative dentistry is Alumina (Al 2 O 3 ), which is one of the hardest and strongest oxides known. The glass reacts with calcium and other ions forming salts and the cement sets [5]. Ceramic materials are used for variety of dental restoration; these include the fabrication of denture teeth, indirect restorative materials such as single crowns, fixed partial dentures; more recently the use of ceramic has been expanded to include inlays and onlays in posterior teeth, implants [6]. Classification of ceramics in dentistry is apparently an impossible task due to vast improvements made in the compositions; Dental ceramics may be classified according to several parameters, such as their use, microstructure (i.e., amount and type of crystalline phase and glass composition), manufacturing temperature, ceramic system, composition, and processing technique. Lasers interactions with tissue are complicated and no single parameter alone will determine how the laser affects the tissue. Dental hard tissue applications include ablation of carious lesions, cavity preparation for restoration, caries detection, endodontic surgery, and the potential for caries preventive therapy. The parameters of prime concern in understanding desirable or undesirable tissue effects are wavelength, pulse duration, absorption properties, scattering, energy, flounce (energy/surface area), power density, repetition rate, number of pulses, pulse duration and pulse shape. A range of laser parameters have been found with which dental enamel can be treated to make it resistant to subsequent dissolution by acid during dental caries. Our studies have demonstrated that treatment of enamel by specific pulsed diode laser irradiation can markedly inhibit subsequent caries progression. During irradiation, heat causes carbonate loss from the carbonated hydroxyapatite mineral, converting it into a low solubility hydroxyapatite-like calcium phosphate. 2. Materials and Methods In this work, diode of 810 nm, tunable output power (30, 200, 500) mw, Ora-laser jet Company Germany, was used [7]. Dental ceramic firing furnace, Centurion Q50 vacuum porcelain furnace, (100-120) V, 50/60 Hz, (33 33 41) cm dimensions, computerized auto control and calibration, Maximum Pressing Firing Temperature 1204. The hardness tester (TH 160), with dimensions of (268 86 50) mm, 50hr Continuous work, Digiwork Instruments Company, Canada, used to provide a wide range for non-distractive test of hardness [8]. The dental ceramic layer was subjected to the test of strength to measure the hardness for each specimen before the laser irradiation (pre test), by using Birnell hardness test. After the irradiation of the all specimens, has been subjected to the hardness test (post test). Principle of the Birnell hardness test an indenter (hard metal ball with diameter D) is forced into the surface of the metals or test piece, and the diameter of the indentation d left the surface after removal of the force F is measured. The Brinell hardness number, or simply the Brinell number, is obtained by dividing the load used, in kilograms, by the actual surface area of the indentation, in square millimeters. The result is a pressure measurement, but the units are rarely stated. Birnell hardness is proportional to the equation obtained by dividing the test force by curved surface, area of the indentation with radius corresponding to half of the diameter of the ball [9]. Test Force BHN = Constant Surface area of indentation where: 2F BHN = 1.102 πd D D d 2 2 ( ) (2.1) 105

BHN Brinell hardness number, F applied force in kg. D diameter of indenter in mm. d diameter of indentation in mm. UVmini-1240 UV-VIS Spectrophotometer of spectral scanning range of (190 to 1100) nm was used in this study to measured absorption spectrum of dental ceramic materials.uvmini-1240 features a variety of standard data acquisition modes [9]. Dental ceramic materials used in this study are powder opaque B 1, and dentine B 1 from Ceramco 3 and used anickel chromium metal. Dental ceramic materials used in this study are powder opaque B 1, and dentine B 1 from Ceramco3.and used anickel chromium metal. 2.1. Preparation of Ceramic Specimens First, anickel chromium as base metal alloy used to fabricate 40 specimens for ceramic material, measuring 10 mm in diameter and 4 mm in thickness of the metal plus a layer of 1.7 mm thickness of the ceramic material. Then, ceramic powder (dentin and opaque powder) was mixed with distilled water to form slurry, and then the mixed slurry was loaded into nickel chromium mold as a layer. Before that, the specimens were placed on a firing tray (Centurion Q50 Vacuum Porcelain Furnace) they were dried and sintered in a vacuum furnace according to manufacturer s specification at temperature of 850 C. Figure 1 shows photographs of the prepared specimens. 2.2. Procedure and Methods Setup Procedure This part has been by using the diode laser from Ora-Laser jet system, invisible laser irradiation, wavelength 810 nm, class 4 laser products, by using power of 30mW 200mW and 500 mw, energy 0.5 J, frequency 50 Hz, pulse pause relation(ppr) 1:1, in a continuous mode (CW). The experimental procedure was done by using Ora-Laser jet system, but forty specimens were used were irradiated at different ways. First way, twenty specimens of dental ceramic divided into two groups, ten in each according to irradiated time, they irradiated with the diode laser 810 nm, at same power of 200 mw, different irradiation time beginning of two minutes for the first group, and change the time to ten minutes for the second group. Second way, twenty specimens of dental ceramic divided into two groups, ten in each according to irradiated power, they irradiated with diode laser 810 nm, at constant duration of one minute, but at variable power of 30 mw to the first group, and change to 500 mw for the second group. The irradiation of specimens is shown in Figure 2. After the irradiation of specimens by the two ways, the specimens were subjected to the hardness test by using birnell hardness test. Figure 3 shows the method for hardness measurements of specimens before and after irradiation. The experimental procedure was done as follows: a) The hardness test for each specimen s dental ceramic layer was measured before the laser irradiation (pre-test), by using the hardness tester (TH 160) Birnell hardness test. b) before begging irradiation the Goggles wired (protective eyewear) for safety. c) Forty specimens of conventional dental ceramic were separated to four groups, ten specimens of each one. Figure 1. Photographs of the specimens. 106

Each group was irradiated with diode laser 810 nm 0.5 J, 50 Hz, pulse pause relation (PPR) 1:1, in a continuous mode (CW) at different in output power of (30, 200, 500) mw and time (1, 2, 10) minutes as two way. Twenty specimens of dental ceramic divided into two groups, ten in each according to irradiated time, they irradiated with the diode laser 810 nm, at same power of 200 mw, different irradiation time (2 and 10) minutes for the first and second group respectively. Twenty specimens of dental ceramic divided into two groups, ten in each according to irradiated power, they irradiated with diode laser810 nm, at same duration of one minute, different power of (30 and 500) mw for first group and the second one respectively. After the irradiation of the all specimens, the hardness test was measured (post-test). The comparison between (pre-test) and (post-test) will be done. 3. Results and Discussion The results of irradiation with diode laser 810 nm, power 200 mw, at two different duration time (2 and 10) minutes, were listed in Table 1 and Table 2 respectively. The hardness for ten specimens measured before and after irradiation by the laser diode laser 810 nm, power 200 mw, at two different duration time (2 and 10) minutes, were plotted in Figure 4 and Figure 5 respectively. The comparison of the hardness average change at irradiation time two and ten minutes, at constant irradiation power at 200 mw, Figure 6, shows little increasing in hardness with increasing irradiation time from two to ten Figure 2. Irradiation of specimens by diode laser (810 nm). Figure 3. The method of hardness measured. 107

Table 1. Measurement of hardness of dental ceramic specimens irradiated by diode laser 810 nm, and power of 200 mw for two minutes. Specimen Number 1 2 3 4 5 6 7 8 9 10 Means (pre-test) (HB) 64 53 38 58 55 51 55 46 56 56 51.1 (post-test) (HB) 87 57 54 56 65 57 67 51 47 65 60.6 Hardness change (HB) 23 4 16 2 10 6 12 5 12 9 9.5 Change% 35.94 7.55 42.11 3.45 18.18 11.76 21.82 10.87 34.29 16.07 18.59 Table 2. Measurement of hardness of dental ceramic specimens irradiated by diode laser 810 nm, and power of 200 mw for ten minutes. Specimen Number 1 2 3 4 5 6 7 8 9 10 Means (pre-test) (HB) 39 37 37 56 45 31 53 33 34 39 40.4 (post-test) (HB) 50 53 49 77 56 36 51 41 45 43 50.1 Hardness change (HB) 11 16 12 21 11 5 2 8 11 4 9.7 Change% 28.21 43.24 37.50 37.50 24.44 16.13 3.77 24.24 32.35 10.26 24.01 Figure 4. Measurement of hardness of dental ceramic specimens before and after irradiated by diode laser 810 nm and power 200 mw for two minutes. Figure 5. Measurement of hardness of dental ceramic specimens before and after irradiated by diode laser 810 nm and power 200 mw for ten minute. minutes. The hardness average change and the percentage of hardness increase with little ratio for irradiation time two to ten minutes, the different between the measurement as shown in Figure 7. 108

Irradiation with (30 and 500) mw at duration one minute: The results of irradiated with power 30 mw and 500 mw at duration one minute were listed in Table 3, and Table 4 respectively. When we irradiate ten specimens of dental ceramic with diode laser 810 nm at power 30 mw, the hardness for these specimens was changes. The hardness increases after irradiation time of one minute. The effective of irradiation specimens measured as hardness. Figure 8 shows the changeable of hardness for all ten specimens. Figure 9 shows plot of increasing of hardness for ten specimens after irradiation with diode laser 810 nm at 9.70 9.65 9.60 Hardness(HL) 9.55 9.50 9.45 9.40 0 2 4 6 8 10 12 Time/min Figure 6. Comparison of hardness measurementfor irradiation time two and ten minute, and t power of 200 mw. Figure 7. Measurement of hardness average change and the percentage of hardness for irradiation time two and ten minutes. Table 3. The hardness measurement of dental ceramic irradiated with diode laser 810 nm and power of 30 mw, for one minute. Specimen Number 1 2 3 4 5 6 7 8 9 10 Means (pre-test) (HB) 38 32 41 39 35 37 37 35 38 40 37.2 (post-test) (HB) 40 36 47 47 42 45 47 36 48 52 44 Hardness change (HB) 2 4 6 8 7 8 10 1 10 12 6.8 Change% 5.26 12.50 14.63 20.51 20 21.62 27.03 2.86 26.32 30 18.28 109

Table 4. The hardness measurement of dental ceramic irradiated with diode laser 810 nm at power of 500 mw, for one minute. Specimens Number 1 2 3 4 5 6 7 8 9 10 Means Hardness without irradiation (HB) 32 35 38 39 32 35 37 35 32 35 35 Hardness after irradiation (HB) 35 38 42 48 28 39 41 37 33 35 37.6 Hardness change (HB) 3 3 4 9 4 4 4 2 1 0 2.6 Change % 9.38 8.57 10.53 23.08 12.50 11.43 10.81 5.71 3.13 0 7.43 Figure 8. Measurement of hardness of dental ceramic specimens before and after irradiated by diode laser 810 nm and power 30 mw for one minute. Figure 9. Shows plot of increasing of hardness for ten specimens after irradiation with diode laser 810 nm at power of 500 mw, and irradiation time one minute. power of 500 mw, and irradiation time one minute. The comparison of hardness average change at constant irradiation time at one minute, was shown on Figure 10. From Figure 10 one was investigatedthat the hardness of dental ceramic was decrease gradually with the irradiationincrease from (30 to 500) mw. The comparison of the hardness percentage of the sample with irradiated by 30 mw to 500 mw at one minute was plotted on Figure 11. Figure 11 shows that the hardness average of the specimens changed, when the irradiated power was changed. The inverse relation was obtainedbetween the percentage of hardness and irradiated power of diode laser, (810 nm) and duration time (1 minute). Discussion of Results of Irradiation with 810nm and Power 30, 200, 500 mw: Based on obtained results, it was noted that an irradiation of specimens with diode laser 810 nm, had increase in hardness of dental ceramic. In irradiation with power 200mW, achieved that at duration two minutes the hardness (18.59%) increased but not large compared with (24.01%) at irradiation time ten minutes, here we concluded that the increase in dura- 110

7 6 5 Hardness(HL) 4 3 2 1 0 0 100 200 300 400 500 600 Power/mW Figure 10. Comparison of the hardness measurement for irradiation time one minute and power of 30 mw and 500 mw. Figure 11. Measurement of hardness average change and the percentage of hardness for irradiation time one minute, at power of 30mW and 500 mw. tion to longest time intervals has no influence in the hardness at irradiation with diode laser 810 nm. In irradiation with low power (30 mw) the hardness percentage was (18.28%) compared to high power (500 mw) it decrease to (7.34%). 4. Conclusion From the obtained results it can be concluded that, the highest ratio of the hardness is achieved at low power laser irradiation (30 mw). While low ratio of hardness obtained at high power irradiation (500 mw), also at irradiation with diode laser (500mW), the dental ceramic with white color becomes very white. The high power caused heat in the dental ceramic material which in turn change the properties of the material, but hardness dose not increase by the large ratio. References [1] Ahluwalia, G.S. (2009) Cosmetic Application of Laser and Light-Based System, William Andrew, 101 (Inc USA). [2] Gary, N. and Gary, A. (1983) Dye Stability under Excaimer Laser Pumping. Applied Physics B, 30, 109-166. [3] Brackmann, U. (1986) Lambdachrome Laser Dyes. First Edition. [4] Gary, N. and Gary, A. (2010) Text Book of Operative Dentistry. Jaypee Brothers, Medical Publishers. 111

[5] Lakshmanan, A. (2012) Sintering of Ceramics_ New Emerging Techniques. InTech, JanezaTrdine 9, 51000 Rijeka, Croatia. [6] Touati, P. and Nathanson, D. (1999) Esthetic Dentistry and Ceramic Resoration. New York, NY, USA. [7] Ora-laser jet, Oralia Medical Gmbh, Instruction Manual Oralia Company Germany. [8] Czichos, H., Saiato, T., Leslie, L. and Smith, R. (2006) Hand Book of Material Measurement Method. Springer Science+Business Media, Inc. [9] Information Provided by Shimadzu, Scientific Instrument.htm. 112