Evaluation of Coronary Bypass Graft Occlusion and Stenosis with 64-Detector-Row Computed Tomography Angiography

Similar documents
Improved Noninvasive Assessment of Coronary Artery Bypass Grafts With 64-Slice Computed Tomographic Angiography in an Unselected Patient Population

Improvement of Image Quality with ß-Blocker Premedication on ECG-Gated 16-MDCT Coronary Angiography

Diagnostic accuracy of dual-source computed tomography in the detection of coronary chronic total occlusion: Comparison with invasive angiography

Chapter 4. Department of Cardiology, Leiden University Medical Center, Leiden, The Netherlands. Department of Radiology,

Spiral Multislice Computed Tomography Coronary Angiography: A Current Status Report

Initial experience with 64-slice cardiac CT: non-invasive visualization of coronary artery bypass grafts

Improving Diagnostic Accuracy of MDCT Coronary Angiography in Patients with Mild Heart Rhythm Irregularities Using ECG Editing

The diagnostic evaluation of dual-source CT (DSCT) in the diagnosis of coronary artery stenoses

Studies with electron beam computed tomography (EBCT) Imaging

Image quality and diagnostic accuracy of 16-slice multidetector computed tomography for the detection of coronary artery disease in obese patients

Diagnostic Accuracy of Computed Tomography Angiography in Patients After Bypass Grafting

2004;77:800 4 MSCT OF CORONARY ARTERY BYPASS GRAFTS. Results. CABG With Adequate Diagnostic Quality

Bypass Graft and Native Postanastomotic Coronary Artery Patency: Assessment With Computed Tomography

Coronary Artery Imaging. Suvipaporn Siripornpitak, MD Inter-hospital Conference : Rajavithi Hospital

Coronary artery bypass grafting has been a historically. Multislice CT Evaluation of Coronary Artery Bypass Graft Patients SYMPOSIA

Diagnostic Accuracy of Noninvasive Coronary Angiography Using 64-Slice Spiral Computed Tomography

Coronary CT Angiography

Optimal image reconstruction intervals for non-invasive coronary angiography with 64-slice CT

Coronary revascularization treatment based on dual-source computed tomography

Angio-CT: heart and coronary arteries

RAMA-EGAT Risk Score for Predicting Coronary Artery Disease Evaluated by 64- Slice CT Angiography

Purpose. Methods and Materials

Chapter. Non-Invasive Coronary Imaging and Assessment of Left Ventricular Function using 16-slice Computed Tomography

Non-invasive Coronary Angiography: the Role, Limitations and Future of 64-Slice Spiral Computed Tomography Coronary Angiography

, David Stultz, MD. Cardiac CT. David Stultz, MD Cardiology Fellow, PGY 6 March 28, 2006

Perspectives of new imaging techniques for patients with known or suspected coronary artery disease

Accuracy of dual-source CT coronary angiography: first experience in a high pre-test probability population without heart rate control

Radiation Dose Reduction and Coronary Assessability of Prospective Electrocardiogram-Gated Computed Tomography Coronary Angiography

A Pictorial Review of Coronary Artery Bypass Grafts at Multidetector Row CT*

Bottom up cardiac CT for CABG assessment to resolve breathing artefact

Impact of 64-Slice Multidetector Computed Tomography on Other Diagnostic Studies for Coronary Artery Disease

TITLE: Multi-Slice Computed Tomography Coronary Angiography for Coronary Artery Disease: A Review of the Clinical Effectiveness and Guidelines

128-slice dual-source CT coronary angiography using highpitch scan protocols in 102 patients

Impact of SSF on diagnostic performance of coronary CT angiography within one heart beat in patients with high heart rate using a 256-row detector CT

Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement

Clinical Medicine Insights: Cardiology

Eur Heart J. 2011;32:637-45

What every radiologist should know about cardiac CT: A case-based pictorial review

Coronary angiography is the standard way of visualizing

M Marwan, D Ropers, T Pflederer, W G Daniel, S Achenbach

Cardiac Computed Tomography

Zurich Open Repository and Archive

Low-dose CT coronary angiography in the step-andshoot mode: diagnostic performance

Diagnostic Accuracy of Angiographic View Image for the Detection of Coronary Artery Stenoses by 64-Detector Row CT

Accuracy of Multislice Computed Tomography in the Preoperative Assessment of Coronary Disease in Patients With Aortic Valve Stenosis

ECG-Gated 16-MDCT of the Coronary Arteries: Assessment of Image Quality and Accuracy in Detecting Stenoses

Horizon Scanning Technology Summary. Magnetic resonance angiography (MRA) imaging for the detection of coronary artery disease

The Final 10-Year Follow-up Results from the Bari Randomized Trial J Am Coll Cardiol (2007) 49;1600-6

Simon Nepveu 1, Irina Boldeanu 1, Yves Provost 1, Jean Chalaoui 1, Louis-Mathieu Stevens 2,3, Nicolas Noiseux 2,3, Carl Chartrand-Lefebvre 1,3

EXPERIMENTAL AND THERAPEUTIC MEDICINE 5: , 2013

Diagnostic Accuracy of Multidetector Computed Tomography Coronary Angiography in Patients With Dilated Cardiomyopathy

Computed Tomography of the Coronary Arteries

Disclosure Information

Non-invasive coronary angiography with high resolution multidetector-row computed tomography

Banding and Step-Stair Artifacts on the Cardiac-CT Caused By Pseudo-Ectopic Beats

Multidetector CT Angiography for the Detection of Left Main Coronary Artery Disease. Rani K. Hasan, M.D. Intro to Clinical Research July 22 nd, 2011

Non-invasive intravenous coronary angiography using electron beam tomography and multislice computed tomography

Noninvasive Coronary Angiography Using Multislice Computed Tomography (MSCT) Jeffrey M. Schussler, MD, Paul A. Grayburn, MD

Effect of dose reduction on image quality and diagnostic performance in coronary computed tomography angiography

ECG Gated CT Aorta in Transcatheter Aortic Valve Implantation

Feasibility of contrast agent volume reduction on 640-slice CT coronary angiography in patients with low heart rate

ROLE OF MULTISLICE COMPUTED TOMOGRAPHY IN CARDIAC IMAGING

Detection of Coronary Artery Stenoses with Thin Slice Multi Detector Row Spiral Computed Tomography Angiography

Cardiac computed tomography: indications, applications, limitations, and training requirements

B-Flow, Power Doppler and Color Doppler Ultrasound in the Assessment of Carotid Stenosis: Comparison with 64-MD-CT Angiography

Computed Tomography of the Coronary Arteries

Is computed tomography angiography really useful in. of coronary artery disease?

A Noninvasive Assessment of CAD

SYMPOSIA. Coronary CTA. Indications, Patient Selection, and Clinical Implications

Ultrasound. Computed tomography. Case studies. Utility of IQon Spectral CT in. cardiac imaging

Multidetector Computed Tomography (MDCT) in Coronary Surgery: First Experiences With a New Tool for Diagnosis of Coronary Artery Disease

b. To facilitate the management decision of a patient with an equivocal stress test.

Chapter. Do Risk Factors influence Diagnostic Accuracy of Non-Invasive Coronary Angiography with Multi-Slice Computed Tomography?

Recent developments in cardiac CT

X-ray coronary angiography is considered the diagnostic

Diagnostic Value of 64-Slice Dual-Source CT Coronary Angiography in Patients with Atrial Fibrillation: Comparison with Invasive Coronary Angiography

Journal of American Science 2017;13(1)

CT angiography techniques. Boot camp

Chapter 45. Utility of Computed Tomographic Coronary Angiography Post Coronary Revascularization BACKGROUND CORONARY ARTERY BYPASS GRAFTING

COMPARISON OF 16-MULTIDETECTOR COMPUTED TOMOGRAPHY VERSUS INVASIVE CORONARY ANGIOGRAPHY IN THE DETECTION OF CORONARY ARTERY IN-STENT RESTENOSIS

Evaluation of Ascending Aortic Atherosclerosis with 16-Multidetector Computed Tomography Is Useful before Total Endoscopic Coronary Bypass Surgery

Computed Tomography Imaging of the Coronary Arteries

Dr Felix Keng. Imaging of the heart is technically difficult because: Role of Cardiac MSCT. Current: Cardiac Motion Respiratory Motion

Image quality and, hence, the diagnostic value of cardiac. Imaging

Cardiac CT: Your chest pain patient CAN be discharged from the Emergency Department

Sixty four slice Computed Tomography Scan (64-slice

Sang Ho Lee, Byoung Wook Choi, Hee-Joung Kim*, Member, IEEE, Haijo Jung, Hye-Kyung Son, Won-Suk Kang, Sun Kook Yoo, Kyu Ok Choe, Hyung Sik Yoo

CT Imaging of Atherosclerotic Plaque. William Stanford MD Professor-Emeritus Radiology University of Iowa College of Medicine Iowa City, IA

A new method for radiation dose reduction at cardiac CT with multi-phase data-averaging and non-rigid image registration: preliminary clinical trial

Index. radiologic.theclinics.com. Note: Page numbers of article titles are in boldface type.

Diagnostic Performance of MDCT for Detecting Aortic Valve Regurgitation

Characteristics of Subclinical Coronary Artery Disease in Diabetic Patients without Known Coronary Artery Disease

An estimated 1.46 million diagnostic cardiac catheterizations

Interpreting CT Angiography: Three-Dimensional Reconstruction Techniques

Noninvasive Assessment of Off-Pump Coronary Artery Bypass Surgery by 16-Channel Multidetector-Row Computed Tomography

Cardiac Imaging Tests

Original Article Application of flash dual-source CT at low radiation dose and low contrast medium dose in triple-rule-out (tro) examination

IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 51, NO. 1, FEBRUARY

Low-Dose Computed Tomography Coronary Angiography With Prospective Electrocardiogram Triggering

The radiation dose in retrospective

Transcription:

Acta Radiologica ISSN: 0284-1851 (Print) 1600-0455 (Online) Journal homepage: http://www.tandfonline.com/loi/iard20 Evaluation of Coronary Bypass Graft Occlusion and Stenosis with 64-Detector-Row Computed Tomography Angiography D. Oncel, G. Oncel, A. Taştan & B. Tamci To cite this article: D. Oncel, G. Oncel, A. Taştan & B. Tamci (2007) Evaluation of Coronary Bypass Graft Occlusion and Stenosis with 64-Detector-Row Computed Tomography Angiography, Acta Radiologica, 48:9, 988-996 To link to this article: https://doi.org/10.1080/02841850701501733 Published online: 04 Aug 2009. Submit your article to this journal Article views: 179 View related articles Full Terms & Conditions of access and use can be found at http://www.tandfonline.com/action/journalinformation?journalcode=iard20

ORIGINAL ARTICLE ACTA RADIOLOGICA Evaluation of Coronary Bypass Graft Occlusion and Stenosis with 64- Detector-Row Computed Tomography Angiography D. ONCEL, G.ONCEL, A.TAŞTAN &B.TAMCI Departments of Radiology and Cardiology, Sifa Hospital, Izmir, Turkey Oncel D, Oncel G, Taştan A, Tamci B. Evaluation of coronary bypass graft occlusion and stenosis with 64-detector-row computed tomography angiography. Acta Radiol 2007;48:988 996. Background: A noninvasive imaging modality is desirable for the evaluation of coronary bypass graft stenosis and occlusion. Purpose: To prospectively evaluate the effectiveness of 64-detector-row computed tomography (DCT) for the assessment of coronary bypass grafts. Material and Methods: Forty-two patients (35 male, seven female, mean age 66.3 years) with 103 bypass grafts (32 arterial, 71 venous) were examined with 64-DCT. The evaluations were done by two radiologists blinded to the results of quantitative coronary angiography (QCA), used as the reference standard. Results: All of the 26 occluded grafts, nine of the 10 stenosed grafts, and 66 of the 67 patent grafts were correctly diagnosed with 64-DCT angiography. The sensitivity, specificity, and positive and negative predictive values for 64-DCT in detecting graft stenosis were 90%, 99%, 90%, and 99%, respectively. For graft occlusion, all were 100%. No statistically significant difference was found between 64-DCT and QCA for the evaluation of bypass grafts. Intermodality and interobserver agreement were excellent. Conclusion: 64-DCT angiography is a reliable, noninvasive diagnostic method for the assessment of coronary bypass grafts. It can be considered as a useful tool for follow-up purposes and may function as a gatekeeper before invasive procedures. Key words: Adults; arteries; cardiac; CT angiography D. Oncel, Sifa Hospital, Fevzipasa Boulevard No: 172/2, 35340 Basmane, Izmir, Turkey (tel. +90 232 4460880, fax. +90 232 4460770, e-mail. dilekoncel@hotmail.com) Accepted for publication May 26, 2007 Coronary artery bypass graft surgery is an established treatment in the management of advanced coronary artery disease. The long-term clinical outcome after myocardial revascularization depends on the patency of the bypass grafts. Up to 10% of grafts become occluded during the perioperative period. Nearly 40% of patients experience recurrence of symptoms within 6 years, and 25% of bypass grafts are found to be occluded at follow-up 5 years after surgery. After 10 years, occlusion rates of 59% and 17% have been reported for venous and arterial grafts, respectively (5, 7). Conventional coronary angiography (CCA) has been considered as the reference standard for the evaluation of coronary artery bypass graft patency and stenosis. However, CCA is an invasive procedure with a significant cost and small procedure-related morbidity and mortality (3). Therefore, a noninvasive imaging modality is highly desirable. Utilization of computed tomography (CT) for the evaluation of bypass grafts has been reported since the early 1980s. Because of their large diameter, limited calcification, and relative immobility, bypass grafts and particularly saphenous vein grafts are well visualized by CT. Due to limited temporal and spatial resolution, single-detector-row spiral CT remained ineffective and was confined to simple patency assessment (22). With four-detector-row computed tomography (DCT) scanners, several studies reported good sensitivity and specificity for the detection of graft occlusion, while diagnostic performance was lower for graft stenosis and failed to define distal anastomosis site patencies (4, 12, 13, 18, 21, 23). With 16-DCT scanners, temporal and spatial resolutions were higher. Significant stenoses were better assessed and the number of unevaluable grafts was reduced. However, evaluation of distal anastomosis still remained a problem because of motion artifacts or artifacts due to surgical clip DOI 10.1080/02841850701501733 # 2007 Taylor & Francis

Evaluating Coronary Bypass Grafts with 64-DCT Angiography 989 material or calcification (1, 6, 19, 20, 21). With 64- DCT technology, the superior temporal and spatial resolution further improved image quality (10, 11, 14 17). Therefore, the aim of our study was to evaluate the diagnostic performance of 64-DCT for the assessment of coronary artery bypass grafts. Material and Methods Patient population The study was approved by the institutional review board, and all patients gave informed consent to participate in the study. In this prospective study, 42 patients with previous bypass grafts (35 male, seven female, mean age 66.3 years, range 49 77 years) were examined between January 2005 and September 2006. A total of 103 bypass grafts were examined. Thirty-two of them were arterial grafts (28 left internal mammarian artery [LIMA] and four right internal mammarian artery [RIMA]) and 71 of them were saphenous vein grafts. All were single grafts. The types and localizations of bypass grafts are summarized in Table 1. The localizations of bypass grafts were specified as outlined by the American Heart Association, which defines coronary arteries in terms of 16 segments (2). The mean interval after bypass graft operation was 50.9 months (range 6 108 months). In all patients, there was suspected bypass graft stenosis or occlusion depending on patient complaints (angina-like symptoms) and/or laboratory findings (positive or suspected stress ECG tests and/or myocardial perfusion scintigraphies). All patients were scheduled for CCA, performed 1 2 days after the CT examination. Patient characteristics are summarized in Table 2. The exclusion criteria for CT were as follows: unstable clinical condition, previous allergic reaction to iodinated contrast agents, irregular heart rate, atrial fibrillation, renal dysfunction (elevated serum creatinine levels w1.5 mg/dl), and failure to follow breath-hold commands. The study protocol included intravenous metoprolol administration in patients with heart rates w70 bpm. Therefore, patients with any contraindications concerning Table 2. Clinical characteristics (42 patients) Age (mean SD), years 66.3 6.2 Male, % 83 Cardiac risk factors Hypertension*, % 43 Hypercholesterolemia{, % 57 Diabetes mellitus, % 45 Current smoking, % 31 Family history of coronary artery disease, % 45 Body-mass index (mean SD), kg/m 2 23.3 3.2 Serum creatinine (mean SD), mg/dl 1 0.32 Previous use of heart-rate-lowering medication, % 74 Reasons for referral to invasive coronary angiography Angina-like symptoms, % 57 Positive or suspected stress ECG test, % 29 Positive or suspected myocardial perfusion 14 scintigraphy, % * Blood pressure >160/95 mmhg, or treatment for hypertension. {Total cholesterol w200 mg/dl, or treatment for hypercholesterolemia. beta-blocker administration (asthma, a v block, congestive heart failure, etc.) were also excluded. During the study period, 27 patients were excluded from the study group either due to the abovementioned contraindications (n515) or due to refusal to participate in the study (n512). CT coronary angiography: scan protocol and reconstruction All CT examinations were performed using a 64- DCT scanner (Sensation Cardiac 64; Siemens, Forcheim, Germany). To achieve optimal image quality, in patients with heart rates exceeding 70 bpm, 5 20 mg intravenous metoprolol (Beloc 5 mg/5 ml; AstraZeneca, Istanbul, Turkey) was administered immediately prior to scanning. In our study group, 35 patients had prescan heart rates (70 bpm (31 of them were already on beta-blocker treatment). Intravenous metoprolol was administered to the remaining seven patients, and in all of them heart rates below 70 bpm were maintained. Also, we administered sublingual nitrate (Isordil 5 mg, isosorbide dinitrate; Fako, Istanbul, Turkey) before scanning to standardize vasomotor tone in the coronary arteries beyond the graft anastomosis. Scan parameters were as follows: slice collimation 3260.6 mm62, rotation time 0.33 ms (effective Table 1. Type and localization of bypass grafts Localizaton of the bypass graft implantation (segment number according to AHA classification) Type of bypass graft n 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Saphenous vein 71 8 13 4 0 0 3 7 5 12 0 5 5 9 0 0 LIMA 28 0 0 0 0 0 11 9 4 3 0 1 0 0 0 0 RIMA 4 3 1 0 0 0 0 0 0 0 0 0 0 0 0 0 Total 103 11 14 4 0 0 14 16 9 15 0 6 5 9 0 0 LIMA: left internal mammarian artery; RIMA: right internal mammarian artery; AHA: American Heart Association.

990 D. Oncel et al. temporal resolution 165 ms), tube voltage 120 kv, tube current (effective mas) 900 mas, pitch 0.2. With "flying spot" technology, the focal spot is continuously modified between two points aligned on the z-axis, and the number of simultaneously acquired slices is doubled (double-z sampling). The scans were performed in the craniocaudal direction with subjects in the supine position, and the scan time was approximately 12 16 s (depending on the volume of coverage) in a single breath-hold. The scanning range was planned individually for each patient to include the extent of the coronary artery bypass grafts, ranging from the subclavian artery (including the proximal segment of the IMA grafts) to the apex of the heart. The mean craniocaudal distance of the volume data set was 17 cm (range 16 19 cm). CT angiography was triggered automatically by the arrival of the main contrast bolus (automatic bolus tracking). A prescan was taken at the level of the aortic root, and a region of interest (ROI) was identified on the ascending aorta. We injected 100 ml nonionic contrast medium (Iomeron 350/ ml, iomeprol; Bracco, Milan, Italy) into an antecubital vein through an 18-gauge catheter at a flow rate of 5.5 ml/s. As soon as the signal density level in the ascending aorta reached a predefined threshold of 150 Hounsfield units (HU), the scan started. The injection of contrast medium was followed by a 40-ml saline chaser bolus at a flow rate of 4 ml/s to wash out contrast from the right ventricle. During the scan, ECG was recorded simultaneously. Continuous data acquisition allowed slice reconstruction at different time positions within the cardiac cycle. In each patient, images were first reconstructed at 65%, 70%, and 75% of the R R interval. If motion artifacts were present, additional reconstruction windows were applied. The reconstruction interval with the least motion artifacts was used for further analysis. When necessary, R-wave indications were manually repositioned to improve the quality of synchronization. Prospective ECG tube-current modulation (ECG pulsing) for the reduction of radiation dose was applied in all patients. Axial images were reconstructed with a slice thickness of 0.75 mm and slice increment of 0.5 mm. For the reconstruction of images, standard medium-soft kernels (B20f) were used. CT coronary angiography was performed successfully in all patients without any complications. CT coronary angiography analysis Evaluation of the images was done by two radiologists (D.O., G.O.), with 5 years of experience regarding cardiac CT, independently and blinded to the results of CCA. The number and course of the coronary artery bypass grafts as obtained from surgical reports were known to both radiologists for each patient. In case of disagreement, a final decision was obtained by consensus. For the evaluation of bypass grafts, axial source images, curved multiplanar reformations (MPR), maximum intensity projections (MIP), and volumerendered images (VR) were used. For post-processing, a Leonardo workstation (Siemens, Forcheim, Germany) was used. Significant stenosis was defined as narrowing of the vessel diameter exceeding 50%. Vessel diameters were measured on reconstructions perpendicularly oriented to the vessel course. Each bypass graft was evaluated to be patent, stenosed, or occluded. Along with the bypass grafts, proximal and distal anastomoses were also evaluated. Image quality was determined on the basis of the presence of artifacts degrading the image, such as motion artifacts, calcification, or metallic surgical materials (sutures, clips, markers, and sternal wires) (1, 4). A three-point grading scale was determined accordingly: 1, non-diagnostic/poor (severe artifacts making evaluation impossible, non-adequate quality for diagnosis); 2, moderate (mild/moderate artifacts but acceptable for routine clinical diagnosis); 3, excellent (no artifacts, with clear delineation of the entire graft). The bypass grafts with score 1 (poor image quality/non-diagnostic) were not considered for further evaluation. The analysis was done on a lesion-by-lesion basis for both false-positive and false-negative results, and the possible reason for each misdiagnosis was evaluated retrospectively. In addition to the overall diagnostic performance of 64-DCT coronary angiography in detecting significant stenoses and occlusion, diagnostic performance was evaluated separately with respect to image quality scores and graft type as well as on a patient-by-patient basis. Conventional coronary angiography: reference standard CCA was performed in all patients by using a biplanar angiography system (Siemens, Erlangen, Germany) with standard techniques, carried out by two cardiologists (A.T. and B.T., with 10 and 5 years of angiography experience, respectively) within 1 2 days after the CT examination. The angiograms were evaluated by one cardiologist

Evaluating Coronary Bypass Grafts with 64-DCT Angiography 991 (A.T.). The cardiologist was aware of the number and locations of grafts, as obtained from surgical reports, but blinded to the results of CT angiography. Each bypass graft was evaluated to be patent, significantly stenosed (defined as a diameter reduction of w50%), or occluded by using the quantitative coronary analysis method. Distal and proximal anastomosis sites were also included in the evaluation. No intracoronary isosorbide dinitrate was employed. Statistical analysis Statistical analysis was performed using commercially available statistical software (SPSS 11.5 for Windows; SPPS Inc., Chicago, Ill., USA). The diagnostic performance of 64-DCT coronary angiography for the evaluation of bypass graft stenosis and occlusion was presented as sensitivity, specificity, and positive (PPV) and negative predictive values (NPV). These diagnostic parameters were expressed with a 95% confidence interval (CI). CCA was regarded as the standard of reference. The McNemar test was used to discover whether there was a statistically significant difference between 64-DCT angiography and CCA in detecting bypass graft stenosis and occlusion. A P value v0.05 was considered to be statistically significant. To avoid bias caused by multiple bypass grafts per patient, the P value was adjusted by using the correction factor C, as defined by GONEN et al. (8). Intermodality and interobserver agreements between 64-DCT angiography and CCA in detecting bypass graft stenosis and occlusion were determined by kappa statistics. According to LANDIS and KOCH (9), a kappa value of 0 indicates poor agreement, 0.01 0.20 slight agreement, 0.21 0.40 poor agreement, 0.41 0.60 moderate agreement, 0.61 0.80 good agreement, and 0.81 1.00 excellent agreement. A power analysis to determine the number of patients to be included in the study was not performed. Results Conventional coronary angiography In conventional angiography, 26 of 103 bypass grafts showed total occlusion (25%). Twenty-two of the occluded grafts were saphenous vein grafts (31%, 22/71), and four of them were LIMA grafts (14%, 4/28). In 10 bypass grafts, significant (>50% narrowing of lumen diameter) stenosis was found (10%, 10/103). Six of the stenoses were in LIMA grafts (21%, 6/28), one was in a RIMA graft (25%, 1/4), and three were in saphenous vein grafts (4%, 3/ 71). The other 67 bypass grafts were shown to be patent with no stenosis (65%, 67/103). In the patient-based analysis, bypass graft stenosis and/or occlusion were found in 29 (69%, 29/42) patients. The remaining 13 (31%, 13/42) patients had patent bypass grafts with no stenosis or occlusion. CT coronary angiography The mean heart rate during the scan was 59 bpm (SD 4.6). In CT angiography, all 26 occluded bypass grafts were correctly diagnosed (Figs. 1 and 2). Image quality assessment was done in the remaining 77 bypass grafts. The image quality was excellent (score 3) in 66 (86%) and moderate (score 2) in 11 bypass grafts (14%). No bypass graft was evaluated to be of poor image quality (score 1). Therefore, all bypass grafts were included in the analysis. The reasons for decreased image quality are summarized in Table 3. Among 10 bypass graft stenoses, nine were correctly demonstrated (Fig. 3A C). One stenosed bypass graft was misdiagnosed as normal. Three of the stenoses were located in saphenous vein grafts. One of these stenoses was located at the distal anastomosis site, and two were at the body of the grafts. All of them were correctly diagnosed, and image quality was excellent in all cases (score 3). One of the stenoses was located at the distal anastomosis site of a RIMA graft. Image quality was excellent (score 3), and it was correctly diagnosed. The remaining six stenoses were located at LIMA grafts. Three of the stenoses were located at the body of the graft. The image quality was excellent (score 3), and all were correctly demonstrated. Three stenoses were located at distal anastomosis sites. Two of them were correctly diagnosed. Image quality was moderate (score 2) for one of them and excellent for the other (score 3). Among the 67 patent bypass grafts, 66 were correctly diagnosed (Fig. 3E H). One patent bypass graft was misdiagnosed as stenosis. Regarding the false-negative result, the stenosis of the graft, which was localized at the distal anastomosis site of a LIMA graft implanted to the proximal segment of the LAD, was considered as a motion artifact resulting from breath-hold insufficiency. In the case of the one false-positive result, the motion artifact secondary to arrhythmia during the scan mimicked a significant stenosis at the distal anastomosis site of a LIMA bypass graft implanted to the proximal segment of the first diagonal branch of the LAD. In both cases, image quality was

992 D. Oncel et al. A B Fig. 1. A 64-year-old male patient with saphenous vein LAD, LIMA D1, and saphenous vein RCA bypass grafts. A. A curved MPR image of the CT angiography image demonstrates the total occlusion of the saphenous vein RCA bypass graft. In the lumen of the graft, thrombosis can be visualized. There is also wall calcification. There are metallic artifacts due to sternal wires, but they do not obscure the visualization of the graft. B. A volume-rendered CT angiography image shows only the stump of the saphenous vein RCA graft on the aorta, corresponding to saphenous vein bypass graft occlusion. The saphenous vein LCX bypass graft could not be visualized on conventional angiography. considered to be moderate (score 2) due to motion artifacts that contributed to the misdiagnosis. According to these results, the sensitivity, specificity, PPV, and NPV for 64-DCT in detecting bypass graft occlusion was 100% for all. For bypass graft stenosis, the sensitivity, specificity, PPV, and NPV was calculated as 90% (9/10, 95% CI 84 96), 99% (66/67, 95% CI 98 100), 90% (9/10, 95% CI A B Fig. 2. A 67-year-old male patient with LIMA LAD and saphenous vein D1 bypass grafts. A. A curved MPR image of the CT angiography image demonstrates total occlusion of the LIMA graft. No flow density is observed within the lumen, and only metallic side-branch clips are visible along the course of the graft. However, the distal LAD demonstrates normal flow, which is supplied by the patent saphenous vein D1 bypass graft. B. A volume-rendered CT angiography image demonstrates the occluded LIMA graft and patent saphenous vein graft. Note the normal flow in the distal LAD. The LIMA LAD graft could not be visualized with conventional angiography, confirming occlusion of the graft.

Evaluating Coronary Bypass Grafts with 64-DCT Angiography 993 Table 3. Reasons for decreased (moderate) image quality in 11 bypass grafts Reason for moderate image quality Saphenous vein LIMA RIMA Motion artifacts 3 5 1 Arrhytmia during scan 1 2 0 Breath-hold insufficiency 2 2 1 Patient movement 0 1 0 Metallic artifacts 0 2 0 Sternal wire 0 1 0 Side-branch clip 0 1 0 Total 3 7 1 LIMA: left internal mammarian artery; RIMA: right internal mammarian artery. 84 96), and 99% (66/67, 95% CI 98 100), respectively. The overall sensitivity, specificity, PPV, and NPV for 64-DCT in detecting bypass graft occlusion and stenosis was 97% (35/36, 95% CI 94 99), 99% (66/67, 95% CI 98 100), 97% (35/36, 95% CI 94 99), and 99% (66/67, 95% CI 98 100), respectively. The diagnostic performance of CT angiography in the evaluation of bypass graft stenosis with respect to graft type and image quality is summarized in Table 4. In the patient-based analysis, all patients with bypass graft stenosis and/or occlusion were correctly diagnosed (n529). Also, all patients with patent bypass grafts with no stenosis or occlusion were correctly classified (n513). In patients with false-positive and false-negative results, there were additional bypass grafts that were correctly diagnosed as occluded or stenosed. Therefore, sensitivity, specificity, PPV, and NPV for the classification of patients with or without bypass graft occlusion and/or stenosis was 100% for all. According to kappa statistics, agreement between 64-DCT and CCA was excellent (k50.885) for the detection of coronary bypass graft stenosis (Table 4). Interobserver agreement was excellent concerning coronary bypass graft stenosis (k50.95) and occlusion (k51). With the McNemar test, the corrected P value was calculated as 0.23. This demonstrated that there was no statistically significant difference between 64- DCT and CCA for the detection of coronary bypass graft stenosis and occlusion. Discussion CCA has been considered the imaging modality of choice for the assessment of coronary artery bypass grafts in patients with recurrent symptoms after bypass graft placement (7). In parallel with the advances in CT technology, multidetector-row CT has emerged as an alternative, noninvasive imaging method in the evaluation of coronary artery bypass grafts. In previous studies with 4-DCT scanners, the main problems were the significant number of unevaluable grafts, failure to define distal anastomosis site patencies, and long scan times (4, 12, 13, 18, 23). With 16-DCT scanners, the number of unevaluable grafts was reduced and scan times were more favorable. Also, the diagnostic performance regarding bypass graft patency and stenosis was high. However, a considerable number of patent grafts were still not eligible for the analysis of highgrade stenosis, especially at distal anastomosis sites (1, 6, 19, 20). Sixty-four-DCT scanners provide superior spatial and temporal resolution. With increased spatial resolution, the blooming effect and beamhardening artifacts related to metallic materials are decreased substantially, while an effective temporal resolution of 165 ms helps to minimize motion artifacts (10, 14, 16). Scan times are also shorter. These improvements are expected to increase the diagnostic performance accordingly. Previously published studies with 64-DCT reveal favorable results in the evaluation of bypass grafts and anastomosis sites, as well as native coronary arteries (11, 15, 17). Our study, in parallel with the literature, demonstrated that 64-DCT performed well in the determination of bypass graft occlusion and stenosis. In our study, all bypass grafts were interpretable. We achieved excellent image quality in 86% (66/77) of visible bypass grafts, and no bypass graft had to be excluded from the study due to poor image quality. This is very important, because evaluation of all bypass grafts is a prerequisite for CT angiography to become a clinically relevant tool for the assessment of patients with suspected bypass graft stenosis or occlusion. In accordance with previously published articles and our own experience, the image quality of different parts of the bypass graft was usually not uniform (1, 13, 18, 23). The proximal segments were rarely affected by motion artifacts, while the body and in particular the distal anastomoses of the bypass grafts were more susceptible to these artifacts. Also, the effect of motion artifacts in image quality was more pronounced in arterial grafts due to thinner luminal diameters. In our study, both of the two misdiagnoses (one falsenegative and one false-positive result) were at the

994 D. Oncel et al. A B C D E F G H Fig. 3. A 57-year-old female patient with LIMA LAD, saphenous vein D1, and saphenous vein LCX bypass grafts. A. A curved MPR image of CT angiography image shows significant stenosis in the proximal part of the saphenous vein LCX graft (arrow). B. MIP image of the CT angiography demonstrates stenosis of the saphenous vein LCX bypass graft (arrow). C. Volume-rendered CT angiography image demonstrates the stenosis (arrow). Also, the LIMA LAD and saphenous vein D1 bypass grafts are seen to be patent. D. Conventional angiography image (left anterior oblique view, cranial angulation) depicts stenosis of the saphenous vein LCX bypass graft. E. MIP image of CT angiography demonstrates the LIMA LAD and saphenous vein D1 bypass grafts with no significant stenoses. The distal anastomosis sites are well shown as normal. F. Volume-rendered CT angiography image shows normal LIMA LAD and saphenous vein D1 bypass grafts and distal anastomosis sites. G. Conventional angiography image (right anterior oblique view) depicts the normal LIMA LAD bypass graft. H. Conventional angiography image (right anterior oblique view) depicts the normal saphenous vein D1 graft. distal anastomosis sites of LIMA grafts and resulted from motion artifacts (secondary to breath-hold insufficiency and unexpected arrhythmia during the scan, respectively). Therefore, motion artifacts, although minimized substantially with 64-DCT scanners, still remain a major cause of image degradation. We used beta-blockers to decrease heart rates below 70 bpm, and this helped to eliminate residual cardiac motion artifacts and improve image quality.

Evaluating Coronary Bypass Grafts with 64-DCT Angiography 995 Table 4. Diagnostic performance of 64-DCT angiography in the evaluation of bypass graft stenosis with respect to graft type and image quality Graft type and image Sensitivity, % Specificity, % PPV, % NPV, % quality Number TP TN FP FN (95% CI) (95% CI) (95% CI) (95% CI) Kappa index, k LIMA 24 5 17 1 1 83 (5/6) 94 (17/18) 83 (5/6) 94 (17/18) 0.778 (68 99) (85 100) (68 99) (85 100) Moderate (score 2) 7 1 4 1 1 50 (1/2) 80 (4/5) 50 (1/2) 80 (4/5) 0.3 (13 87) (51 100) (13 87) (51 100) Excellent (score 3) 17 4 13 0 0 100 (4/4) 100 (13/13) 100 (4/4) 100 (13/13) 1 RIMA 4 1 3 0 0 100 (1/1) 100 (3/3) 100 (1/1) 100 (3/3) 1 Moderate (score 2) 1 0 1 0 0 NA 100 (1/1) NA 100 (1/1) NA Excellent (score 3) 3 1 2 0 0 100 (1/1) 100 (2/2) 100 (1/1) 100 (2/2) 1 Saphenous vein 49 3 46 0 0 100 (3/3) 100 (46/46) 100 (3/3) 100 (46/46) 1 Moderate (score 2) 3 0 3 0 0 NA 100 (3/3) NA 100 (3/3) NA Excellent (score 3) 46 3 43 0 0 100 (3/3) 100 (43/43) 100 (3/3) 100 (43/43) 1 Total 77 9 66 1 1 90 (9/10) 99 (66/67) 90 (9/10) 99 (66/67) 0.885 (84 96) (97 100) (84 96) (97 100) Moderate (score 2) 11 1 8 1 1 50 (1/2) 89 (8/9) 50 (1/2) 89 (8/9) 0.389 (20 80) (71 100) (20 80) (71 100) Excellent (score 3) 66 8 58 0 0 100 (8/8) 100 (78/78) 100 (8/8) 100 (78/78) 1 TP: true positive; TN: true negative; FP: false positive; FN: false negative; PPV: positive predictive value; NPV: negative predictive value; LIMA: left internal mammarian artery; RIMA: right internal mammarian artery; CI: confidence interval; NA: not applicable. In our study, metallic artifacts caused reduced image quality in only three bypass grafts (all arterial). However, they did not lead to misdiagnosis, and the images were eligible for correct evaluation. This low number can be explained by the improved spatial resolution of 64-DCT, resulting in decreased metallic artifacts. Concerning image quality and the evaluation of stenosis, the better performance of CT angiography in venous grafts compared to arterial grafts was probably a result of their larger diameters and fewer metallic artifacts. In our study, the overall diagnostic accuracy of 64-MDCT in detecting bypass graft occlusion and stenosis was very high, and in the patient-based analysis all patients with or without bypass graft occlusion and/or stenosis were correctly classified. Therefore, when referral to catheterization is questionable, CT coronary angiography may identify patients without bypass graft occlusion and/or stenosis, and decrease the number of unnecessary invasive procedures. We acknowledge certain limitations in our study. First, our patients comprised a high pre-test probability population referred for invasive angiography with clinical suspicion of bypass graft occlusion or stenosis, which may have resulted in an overestimation of the ability of 64-DCT to detect and to rule out bypass graft stenosis and occlusion. Wider applicability to an asymptomatic population with previous bypass grafts may yield different results. Another limitation may be the assessment of the stenosis of bypass grafts only. Native coronary arteries were not included in the analysis. Also, while evaluating the image quality of bypass grafts, we did not divide the grafts into segments. However, this did not complicate the evaluation, because image quality was excellent in a substantially high number of grafts (86%, 66/77). The radiation exposure inherent with CT was another important limitation of the study. CT coronary angiography was associated with substantial irradiation to the patients, even though we applied ECG pulsing for dose-saving purposes in all of our patients. In conclusion, our results with 64-DCT demonstrated that CT coronary angiography is a reliable, noninvasive diagnostic method for the evaluation of coronary artery bypass graft occlusion and stenosis. It provides important diagnostic information in a faster, less expensive, more patient-friendly, and safer manner than CCA. It can thus be considered as a useful tool, especially for follow-up purposes, and may function as a gatekeeper before invasive coronary procedures. Future improvements in CT

996 D. Oncel et al. technology may overcome the present limitations of this technique and may replace conventional angiography for diagnostic purposes. References 1. Anders K, Baum U, Schmid M, Ropers D, Schmid A, Pohle K, et al. Coronary artery bypass graft (CABG) patency: assessment with high-resolution submillimeter 16-slice multidetector-row computed tomography (MDCT) versus coronary angiography. Eur J Radiol 2006;57:336 44. 2. Austen WG, Edwards JE, Frye RL, Gensini GG, Gott VL, Griffith LS, et al. A reporting system on patients evaluated for coronary artery disease. Report of the ad hoc committtee for grading of coronary artery disease, council on cardiovascular surgery, American Heart Association. Circulation 1975;51:5 40. 3. Bashore TM, Bates ER, Berger PB, Clark DA, Cusma JT, Dehmer GJ, et al. American Collage of Cardiology/Society for Cardiac Angiography and Interventions Clinical Expert Consensus Document on cardiac catheterization laboratory standards: a report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents. J Am Coll Cardiol 2001;37:2170 214. 4. Burgstahler C, Kuettner A, Kopp AF, Herdeg C, Martensen J, Claussen CD, et al. Non-invasive evaluation of coronary artery bypass grafts using multi-slice computed tomography: initial clinical experience. Int J Cardiol 2003;90:275 80. 5. Campeau L, Enjalbert M, Lesparance J, Vaislic C, Grondin CM, Bourrassa MG. Atherosclerosis and late closure of aortacoronary saphenous vein grafts: sequential angiographic studies at 2 weeks, 1 year, 5 to 7 years, and 10 to 12 years after surgery. Circulation 1983;68: II1 7. 6. Chiurlia E, Menozzi M, Ratti C, Romagnoli R, Modena MG. Follow-up of coronary artery bypass graft patency by multislice computed tomography. Am J Cardiol 2005;95:1094 7. 7. Fitzgibbon GM, Kafka HP, Leach AJ, Kean WJ, Hooper GD, Burton JR, et al. Coronary bypass graft fate and patient outcome: angiographic follow-up of 5065 grafts related to survival and reoperation in 1388 patients during 25 years. J Am Coll Cardiol 1996;28: 616 26. 8. Gonen M, Panageas KS, Larson SM. Statistical issues in analysis of diagnostic imaging experiments with multiple observations per patient. Radiology 2001;221:763 7. 9. Landis JR, Koch GG. An application of hierarchical kappa-type statistics in the assessment of majority agreement among multiple observers. Biometrics 1977;33:363 74. 10. Leber A, Knez A, von Ziegler F, Becker A, Nikolaou K, Paul S, et al. Quantification of obstructive and nonobstructive coronary lesions by 64-slice computed tomography. J Am Coll Cardiol 2005;46:147 54. 11. Malagutti P, Nieman K, Meijboom WB, von Mieghem CA, Pugliese F, Cademartiri F, et al. Use of 64-slice CT in symptomatic patients after coronary bypass surgery: evaluation of grafts and coronary arteries. Eur Heart J 2006 [Epub ahead of print]. 12. Marano R, Storto ML, Maddestra N, Bonomo L. Noninvasive assessment of coronary artery bypass graft with retrospectively ECG-gated four-row multi-detector spiral computed tomography. Eur Radiol 2004;14: 1353 62. 13. Nieman K, Pattynama PM, Rensing BJ, Van Geuns RJ, De Feyter PJ. Evaluation of patients after coronary artery bypass surgery: CT angiographic assessment of grafts and coronary arteries. Radiology 2003;229: 749 56. 14. Oncel D, Oncel G, Tastan A, Tamci B. Detection of significant coronary artery stenosis with 64-section MDCT angiography. Eur J Radiol 2007 [Epub ahead of print]. 15. Pache G, Saueressig U, Frydrychowicz A, Foell D, Ghanem N, Kotter E, et al. Initial experience with 64- slice cardiac CT: non-invasive visualization of coronary artery bypass grafts. Eur Heart J 2006;27:976 80. 16. Raff GL, Gallagher MJ, O Neill WW, Goldstein JA. Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography. J Am Coll Cardiol 2005;46:552 7. 17. Ropers D, Pohle FK, Kuettner A, Pflederer T, Anders K, Daniel WG, et al. Diagnostic accuracy of noninvasive coronary angiography in patients after bypass surgery using 64-slice spiral computed tomography with 330-ms gantry rotation. Circulation 2006;114:2334 41. 18. Ropers D, Ulzheimer S, Wenkel E, Baum U, Giesler T, Derlien H, et al. Investigation of aortacoronary artery bypass grafts by multislice spiral computed tomography with electrocardiographic-gated image reconstruction. Am J Cardiol 2001;88:792 5. 19. Salm LP, Bax JJ, Jukema JW, Schuijf JD, Vliegen HW, Lamb HJ, et al. Comprehensive assessment of patients after coronary artery bypass grafting by 16-detector-row computed tomography. Am Heart J 2005;150:775 81. 20. Schlosser T, Konorza T, Hunold P, Kuhl H, Schmermund A, Barkhausen J, et al. Noninvasive visualization of coronary artery bypass grafts using 16- detector row computed tomography. J Am Coll Cardiol 2004;44:1238 40. 21. Stein PD, Beemath A, Skaf E, Kayali F, Janjua M, Alesh I, et al. Usefulness of 4-, 8-, 16-slice computed tomography for detection of graft occlusion and patency after coronary artery bypass grafting. Am J Cardiol 2005;96:1669 73. 22. Tello R, Costello P, Ecker CP, Hartnell G. Spiral CT evaluation of coronary artery bypass graft patency. J Comput Asist Tomogr 1993;17:253 9. 23. Willmann JK, Weishaupt D, Kobza R, Verdun FR, Seifert B, Marincek B, et al. Coronary artery bypass grafts: ECG-gated multi-detector row CT angiography influence of image reconstruction interval on graft visibility. Radiology 2004;232:568 77.