PTCA Dilatation Catheter. Instructions for Use

Similar documents
PTCA Dilatation Catheter. Instructions for Use

RECOMMENDED INSTRUCTIONS FOR USE

NON-COMPLIANT PTCA RAPID EXCHANGE DILATATION CATHETER

The SplitWire Percutaneous Transluminal Angioplasty Scoring Device. Instructions for Use

1 Description. 2 Indications. 3 Warnings ASPIRATION CATHETER

AXS Catalyst Distal Access Catheter

ER REBOA Catheter. Instructions for Use

Emerge. PTCA Dilatation Catheter ONLY. monorail. over-the-wire

PTA Balloon Dilatation Catheter

Directions For Use. All directions should be read before use

Balloon in Balloon (BIB )

PTA Balloon Dilatation Catheter

Balloon in Balloon (BIB )

Figure 1: Revolution TM Peripheral Atherectomy System Diagram. Table 1: Revolution TM Peripheral Atherectomy System Specifications Minimum Burr

Advanced Innovation for Exceptional Performance

Instructions for Use 1

Peripheral Intravascular Lithotripsy (IVL) Catheter Instructions for Use (IFU)

LeMaitre Embolectomy Catheter

Z-MED II BALLOON AORTIC AND PULMONIC VALVULOPLASTY CATHETER. Instructions for Use

INSTRUCTIONS FOR USE

Directions For Use. All directions should be read before use. Page 1 of 8

Innovation by design. Technology that sets a new standard

1 Comparison of Warfarin and Aspirin for Symptomatic Intracranial Arterial Stenosis. N Engl J Med 352;13, March 31, 2005

Polyurethane Dual Lumen Occlusion Catheter English Instructions for Use. Polyurethane Dual Lumen Occlusion Catheter

DEPARTMENT OF HEALTH & HUMAN SERVICES Public Health Service

Pruitt Irrigation Occlusion Catheter. English Instructions for Use. Pruitt Irrigation Occlusion Catheter

Instructions for Use Cordis PRECISE PRO Rx Nitinol Stent System

Caution: Federal (U.S.A.) law restricts this device to sale by or on the order of a physician.

Endorectal Balloon (ERB) Endorectal Balloon (ERB) Instructions for Use

DURABLE. CONSISTENT. SAFE. IN.PACT Admiral Drug-Coated Balloon

Cardiva Catalyst III INSTRUCTIONS FOR USE

Wolverine Coronary Cutting Balloon

Instructions for Use Reprocessed LASSO Circular Mapping Diagnostic Electrophysiology (EP) Catheter

Single Pass MCA Revascularization with Trevo

ASAHI Corsair INSTRUCTIONS FOR USE

Radux StandTall Instructions for Use Sheath Extender and Securement Clasp

ROTABLATORTM. Peripheral. Rotational Atherectomy System. Quick Reference Cards

TYSHAK DILATATION CATHETER. Instructions for Use CAUTION: Federal (USA) Law restricts this device to sale by or on the order of a physician.

BTK Case Studies Joseph Cardenas, MD AZ Heart & Vascular, Yuma, AZ

Instructions for Use Reprocessed 3D Diagnostic Ultrasound Catheters

REBEL. Platinum Chromium Coronary Stent System. Patient Information Guide

Excimer Laser for Coronary Intervention: Case Study RADIAL APPROACH: CORONARY LASER ATHERECTOMY FOR CTO OF THE LAD FOLLOWED BY PTCA NO STENTING

Assurant Cobalt Iliac BALLOON EXPANDABLE STENT SYSTEM

CLARIVEIN INFUSION CATHETER

System.

Azur CX 35 Peripheral Coil System (Detachable) Instructions for Use

Ruby Coil. Large Volume Detachable Coils

SYMBOLOGY. = Manufacturer. = Manufacturing Serial Number. = Manufacturing Lot Number = Catalog Number LOT REF. = Do not resterilize Single Use Only

Quick Reference Guide

Sirolimus drug chemical structure

CP STENT. Large Diameter, Balloon Expandable Stent

St. Jude Medical 8-Channel Adapter. Clinician's Manual

Talent Abdominal Stent Graft

INSTRUCTIONS FOR USE FOR:

Single Use Curlew TM Multiple Biopsy Forceps

Allium Trans-hepatic Biliary Stent (BIS)

Pruitt-Inahara Carotid Shunt

The Art of. Flow Restoration. Ikazuchi Zero. Semi-Compliant PTCA Balloon OVERVIEW CROSSABILITY LOW PROFILE CASE STUDY CODES

MICHAEL R. JAFF, DO MASSACHUSETTS, UNITED STATES. Medtronic Further. Together

Lutonix AV Clinical Trial

Instructions for Use Reprocessed Arthroscopic Shavers

Instructions for Use Reprocessed Ethicon ENDOPATH XCEL TM Bladeless Trocar with OPTIVIEW Technology

Vascu-PICC WITH CUFF PERIPHERALLY INSERTED CENTRAL VEIN ACCESS CATHETER INSTRUCTIONS FOR USE

Instruction for Use of 3-stage Dilation Balloon Catheter JS-CE-SM-08-01, A/0

Express LD Iliac. Premounted Stent System ONLY. over-the-wire

Instructions for Use Reprocessed Diagnostic Electrophysiology Catheters

NIRxcell CoCr Coronary Stent System

Pocket Reference Guide For (CTO) Technologies

DISRUPT PAD. (( Data Summary )) DISRUPT PAD Data Summary SPL Rev. B 2016 Shockwave Medical Inc. All rights reserved.

Coronary Stent System Instructions for Use. Koronares Stentsystem Gebrauchsanleitung. Système d endoprothèse coronaire Mode d emploi

Peel-Apart Percutaneous Introducer Kits for

JETSTREAM Atherectomy System DELIVERING VERSATILITY TO RESTORE FLOW

Understanding aneurysms and flow diversion treatment

ARROW ENDURANCE. Extended Dwell Peripheral Catheter System. Rx only.

Combine the best of both worlds

WallFlex Biliary RX Partially Covered Stent System Prescriptive Information

FLEXIC ATH LTD. Peripherally Inserted. Instructions n For Use.

ULTRA ICE PLUS ULTRASOUND IMAGING CATHETER. Know where you are. See what you want to avoid.

Instructions for Use ANGIOGUARD XP Emboli Capture Guidewire System

Advisor FL Circular Mapping Catheter, Sensor Enabled D-AVSE-D10-F20, D-AVSE-DF10-F20, D-AVSE-D10-F15, D-AVSE-DF10-F15. Instructions for Use

Bifurcated system Proximal suprarenal stent Modular (aortic main body and two iliac legs) Full thickness woven polyester graft material Fully

Chronic Total Occlusion (CTO) Technologies

Finally, the Control You Need to Deliver Accurate Treatment

CAUTION: FEDERAL (USA) LAW RESTRICTS THIS DEVICE TO SALE BY OR ON THE ORDER OF A PHYSICIAN.

Neuroform EZ Stent System

Coronary angiography and PCI

eptfe Vascular Graft Instructions for Use

MULTILAYER FLOW MODULATOR (MFM ) FOR PERIPHERAL ANEURYSMS TREATMENT (LOWER LIMBS, VISCERALS AND SUBCLAVIAN)

A PATIENT`S GUIDE TO CORONARY ARTERY DISEASE. AND YOUR NIRxcell CoCr CORONARY Stent on RX System

Initial placement 24FR Pull PEG kit REORDER NO:

7 OVERVIEW OF CLINICAL STUDIES:... 3

OptiCross MHz Peripheral Imaging Catheter

Solving the Dilemma of Ostial Stenting: A Case Series Illustrating the Flash Ostial System

LUTONIX DCB in BTK Update on the BTK clinical program & single center experience

Per-Q-Cath* PICC Catheters with Excalibur Introducer* System

CTO Product Portfolio

COIL SYSTEM ORDERING INFORMATION

Every heartbeat is precious. Thanks to you, he ll have 100 million more.

Instructions for Use Reprocessed ENDOPATH XCEL Bladeless Endoscopic Trocars and Cannulas. Reprocessed Device for Single Use.

ThruPort systems ProPlege peripheral retrograde cardioplegia device

Transcription:

PTCA Dilatation Catheter Instructions for Use Rx ONLY Caution: Federal law restricts this device to sale by or on the order of a physician STERILE. Sterilized with ethylene oxide gas Distributed by Medinol USA Inc. 8 Campus Drive, Parsippany, NJ 07054, USA Visit www.medinol.com or call 1-800-477-5801

TABLE OF CONTENTS 1 Device Description 2 Indications for Use Page 4 3 Contraindications 4 How the device is supplied 5 Warnings 6 Precautions 7 Potential Adverse Events / Complications 8 Operator s Manual Page 5 8.1 Inspection Prior to Use 8.2 Equipment and Materials Required 8.3 NC Gallant TM Preparation 8.4 Procedure Page 6 8.5 Catheter Exchange Technique 9 Disclaimer of Warranty and Limitation of Remedy 3

INSTRUCTIONS FOR USE NC Gallant TM PTCA Dilatation Catheter 1 Device Description Caution Carefully read all instructions, warnings and precautions prior to use. Failure to do so may result in complications. The NC Gallant PTCA Dilatation Catheter is a double lumen catheter comprising an expandable balloon on a rapid exchange (RX) catheter. It is a rapid-exchange design, and is therefore assembled from a combination of single lumen and dual lumen tubing. One lumen, which starts at the Catheter's proximal side and ends at the balloon, is used for inflation of the balloon with contrast medium. The second lumen, from the RX-port section to the distal tip, permits the use of a guide wire to facilitate advancement of the NC Gallant to and through the stenosis to be dilated. The distal shaft of the NC Gallant including the folded balloon is coated with a hydrophilic coating. The catheter's distal tip is composed of two components: a metal spring and a soft jacket, partially covering the spring. The device has two platinum-iridium radiopaque marker bands defining the balloon's working length, and aiding in positioning the balloon in the stenosis. Additionally, the proximal shaft has proximal (exit) markers which aid in gauging NC Gallant position relative to the guiding catheter tip (one marker is for femoral guiding catheters and the other marker is for brachial guiding catheters). The usable length of the NC Gallant is 137.5-147.5cm with proximal shaft profile of 2.1F (0.70mm). For catheters with balloon diameters of 2.00-3.75mm the distal shaft profile is 2.7F (0.90mm). For catheters with balloon diameters of 4.00-5.00mm distal shaft profile is 2.95F (0.98mm). The catheter RX port (the guide wire access) 260±60 mm proximal to the distal tip. Table 1: NC Gallant TM Specifications BaLLoon LaBELED DIaMETER (MM) MInIMuM GuIDInG CaTHETER CoMPaTIBILITY (ID) 2 Indications for Use The NC Gallant TM is indicated for: Balloon dilatation of the stenotic portion of a coronary artery or bypass graft stenosis for the purpose of improving myocardial perfusion; Post-deployment stent expansion. nominal PRESSuRE (atm) RaTED BuRST PRESSuRE RBP (atm) CRoSSInG PRoFILE 2.00 5f (0.056") 12 18 0.90 mm 2.25 5f (0.056") 12 18 0.90 mm 2.50 5f (0.056") 12 18 0.90 mm 2.75 5f (0.056") 12 18 0.95 mm 3.00 5f (0.056") 12 18 0.95 mm 3.25 5f (0.056") 12 18 0.95 mm 3.50 5f (0.056") 12 18 0.95 mm 3.75 5f (0.056") 12 18 1.05 mm 4.00 5f (0.056") 12 18 1.05 mm 4.50 6f (0.070") 12 18 1.10 mm 5.00 6f (0.070") 12 18 1.15 mm 3 Contraindications The NC Gallant TM is not intended to be used: In an unprotected left main coronary artery; To treat coronary artery spasm in the absence of a significant stenosis. 4 How the device is supplied STERILE: This device is Ethylene Oxide (ETO) sterilized and is non-pyrogenic. FOR SINGLE USE ONLY: Do not reuse, do not re-sterilize. USE PRIOR TO: The expiration date ( Use By date). CONTENTS: One (1) NC Gallant TM ; one (1) flushing tool. STORAGE: Store in a cool, dark, dry place. 5 Warnings The device is for a single use only. Do not re-sterilize and/or reuse the device; as this can compromise device performance and increase the risk of cross contamination due to inappropriate reprocessing. Do not use the NC Gallant TM if catheter shaft is bent, kinked or distorted in any way. Use a new NC Gallant TM instead. Do not expose the NC Gallant TM to organic solvents such as alcohol or detergents. Percutaneous transluminal coronary angioplasty (PTCA) should only be performed by trained, professional medical doctors, at hospitals where emergency facilities are available, and emergency coronary artery bypass graft surgery can be readily performed in the event of potentially injurious or life-threatening complication. Only the recommended balloon inflation medium is to be used when performing PTCA procedures. Gaseous media should never be used to inflate the balloon. Balloon pressure should not exceed the rated burst pressure (RBP). The RBP is based on results of in vitro testing; and at least 99.9% of the balloons (with 95% confidence) will not burst at a pressure below their RBP. Use of a pressure monitoring device is recommended to prevent over-pressurization. To reduce the potential for vessel damage, the inflated diameter of the balloon should approximate the diameter of the vessel just proximal and distal to the stenosis. When the catheter is exposed to the vascular system, it should be manipulated while under high quality fluoroscopic observation. Do not advance or retract the catheter unless the balloon is fully deflated under vacuum. If resistance is met during manipulation, determine the cause of the resistance under fluoroscopy before proceeding. Recovery of damaged/separated catheters should be performed at the discretion of the physician and based on determination of individual patient condition and appropriate retrieval protocol. PTCA in patients who are not acceptable candidates for coronary artery bypass graft surgery requires careful consideration, including possible hemodynamic support during PTCA, as treatment of this patient population carries special risk. Careful consideration is required in patients for whom anticoagulation is not indicated. Use extreme caution and careful judgement in patients who have severe reaction to contrast agents that cannot be adequately premedicated. Treatment of moderately or heavily calcified lesions is considered to be moderate risk, with an expected success rate of 60 85%, and increases the risk of acute closure, vessel trauma, balloon burst, balloon entrapment, and associated complications. If resistance is felt, determine the cause before proceeding. Continuing to advance or retract the catheter while under resistance may result in damage to the vessels and / or damage / separation of the catheter. Do not torque the catheter more than one (1) full turn. 6 Precautions Use the catheter prior to the: "Use By" date specified on the package. Before angioplasty, the catheter should be examined to verify functionality and ensure that its size and shape are suitable for the specific procedure for which it is to be used. Inspect all products prior to use. Do not use if the package is opened or damaged, or if there is any indication that the product has been damaged. The NC Gallant TM should be used only by physicians trained in percutaneous transluminal coronary angioplasty. Appropriate anticoagulant and coronary vasodilator therapy must be administered to the patient throughout the procedure as needed. Medicine regimen should continue for a period of time deemed fit by the physicians. When back-loading the catheter on the guidewire, provide adequate support to shaft segment. The safety and effectiveness of the NC Gallant TM for the treatment of in-stent restenosis (ISR) have not been established. 4

7 Potential Adverse Events / Complications Known adverse events (alphabetical order) that may be associated with the use of non-compliant dilatation catheters include, but are not limited to: Acute myocardial infraction Acute vessel closure/abrupt closure of main artery or side branch Arrhythmias, including ventricular fibrillation Arteriovenous fistula Cardiac tamponade/pericardial effusion Cardiogenic shock Cerebrovascular accident/stroke/tia Coronary aneurysm Coronary artery bypass graft surgery Coronary artery spasm Coronary vessel dissection, perforation, rupture or injury Death Drug reactions, allergic reaction to contrast medium Embolism Stroke, air embolism and embolization or fragmentation of thrombotic or athlerosclerotic material Hemodynamic compromise Hemorrhage or hematoma Hypotension / Hypertension Infection and pain at the insertion site Minor vessel trauma Myocardial ischemia Pain Percutaneous re-intervention Pseudoaneurysm (at site of catheter insertion) Pyrogenic reaction / Infection Renal failure Respiratory insufficiency Restenosis of the dilated vessel Slow flow/no reflow Thrombosis Total occlusion of the coronary artery or bypass graft Unstable angina or Chronic Angina Vasovagal reactions Ventricular arrhythmia Volume overload 8 Operator s Manual 8.1 Inspection Prior to Use Before opening, carefully inspect the NC Gallant TM package for damage to the sterile barrier. Do not use if the device packaging is damaged. 8.2 Equipment and Materials Required The following table lists the equipment and materials required for the procedure. Table 2: Required Equipment and Materials 8.3 NC Gallant TM Preparation EquIPMEnT Carefully extract the catheter from the hoop. Carefully remove the balloon cover tube and mandrel. If unusual resistance is felt during removal of the balloon cover tube and mandrel, do not use this product. Using the flushing tool supplied by Medinol or a similar device - flush the catheter with sterile heparinized normal saline solution. Evacuate air from the balloon segment using the following procedure: Fill a 20cc syringe or the inflation device with approximately 4cc of 50% contrast medium diluted 1:1 with normal saline. Attach the 20cc syringe or the inflation device to the balloon inflation port. Orient the NC Gallant TM with the distal tip and the balloon pointing in a downward vertical position. Apply negative pressure and aspirate for 15 seconds. Gradually and continually release the pressure to neutral, enabling contrast medium to fill the shaft of the NC Gallant TM. Disconnect the syringe or the inflation device from the balloon inflation port. Drain all air from the syringe or the inflation device barrel. Reconnect the syringe or the inflation device to the inflation port of the NC Gallant TM. Reapply negative pressure and aspirate until bubbles no longer appear during aspiration, and air no longer returns to the device. Gradually and continually release the device pressure to neutral. quantity nc gallant tm 1 flushing tool (provided with the nc gallant) or a similar device 1 sterile Heparinized normal saline (Hepns) Appropriate guiding catheter (see table 1) 1 Hemostatic valve / rotating hemostatic valve with an appropriate internal diameter 1 50% contrast medium diluted 1:1 with normal saline na 20cc syringes 1-3 Inflation device 1-3 three-way stopcock 2-3 0.014" (0.36mm) diameter guidewire 1 guidewire introducer 1 guidewire torque device 1 Appropriate medicinal supply (anticoagulant and coronary vasodilator therapy) 500cc Disconnect the syringe (if used) and connect the inflation device to the inflation port of the NC Gallant TM. Make sure no air is introduced into the catheter. Caution if air is seen in the shaft, repeat NC Gallant TM preparation to prevent uneven balloon inflation. na Prior to using the device, carefully remove the NC Gallant TM from the package and inspect for bends, kinks and other damage. Do not use if there is any indication that the product has been damaged. 5

8.4 Procedure Prepare vascular access site according to standard practice. Insert a compatible guidewire through the hemostatic valve. Carefully advance the guidewire into and through the guiding catheter. Once insertion of the guidewire is complete, withdraw the guidewire introducer, if used. NOTE A dual hemostatic valve should be used when using dual wire technique. Special care should be taken when introducing, torqueing, and removing one or both wires. Guidewires should not be rotated more than 180 degrees in either direction during the dual wire procedure, to avoid entanglement. It is advised to firstly completely withdraw one wire from the patient, before removing any additional equipment. At the physician discretion, attach a torque device to the guidewire. Under fluoroscopy, advance the guidewire to the desired vessel, then carefully across the stenosis. Backload the distal tip of the NC Gallant TM onto the proximal portion of guidewire. Make sure that the guidewire emerges from the notch located approximately 22cm proximal to the balloon. NOTE Support the NC Gallant TM when backloading it onto the guidewire. Advance the NC Gallant TM over the guidewire until it approaches the hemostatic valve. Open the hemostatic valve. Insert the NC Gallant TM, while maintaining guidewire position, until the catheter reaches the lesion. NOTES Support the NC Gallant TM and firmly grasp the proximal shaft while advancing the NC Gallant TM into the guiding catheter. Catheter diameter differences should be taken into consideration when opening and tightening the hemostatic valve and upon withdrawal of the NC Gallant TM. a. Tighten the hemostatic valve to create a seal around the NC Gallant TM without inhibiting intentional movement of the NC Gallant TM, allowing continuous recording of proximal coronary artery pressure. NOTE Do not over tighten the hemostatic valve, to avoid restricting the flow of contrast medium into and out of the balloon or restricting guidewire movement. b. Advance the NC Gallant TM until the appropriate proximal exit marker (located on the proximal shaft) aligns with the hemostatic valve hub. Advance the NC GallantTM over the guidewire and into the stenosis or stent. Utilize radiopaque markers to position the balloon. Use very low pressure to inflate the balloon (1 atm, 1 bar or 15 psi) to confirm correct positioning of the balloon. 8.5 Catheter Exchange Technique Make sure the balloon is fully deflated. Loosen the hemostatic valve. In one hand hold the guidewire and hemostatic valve, while holding the balloon shaft in the opposite hand. Hold the guidewire steadily and slowly begin pulling the NC Gallant TM out of the guiding catheter. Continuously monitoring the guidewire position under fluoroscopy. Withdraw the deflated NC Gallant TM slowly and gradually until the flexible, distal portion of the NC Gallant TM exits the hemostatic valve, while maintaining the guidewire's position across the lesion. Completely remove the NC Gallant TM from the guidewire. Prepare next NC Gallant TM to be used, as previously described in the NC Gallant TM preparation section. Backload another NC Gallant TM onto the guidewire, as previously described in the procedure section and continue the procedure accordingly. 9 Disclaimer of Warranty and Limitation of Remedy Medinol does not provide any expressed or implied warranty, including without limitation, any implied warranty of merchantability, fitness for a particular purpose or non-infringement, with respect to the product(s) described in this publication and Medinol hereby expressly disclaims any such warranties. Descriptions or specifications in Medinol printed matter, including this publication, are meant solely to generally describe the relevant product at the time of manufacture and do not constitute any express warranties. No person has the authority to bind Medinol to any representation or warranty. Under no circumstances shall Medinol be liable for any medical or other expenses or direct, indirect, incidental, consequential, punitive or exemplary damages with respect to the products described herein, including without limitation, in respect of any use, defect, failure or malfunction, whether based upon warranty, contract, tort or other legal theory, even if Medinol has been advised or should have been aware of the possibility of such damages, other than as expressly provided by specific law without possibility of exclusion. The exclusions, disclaimers and limitations contained in this section shall be interpreted in such manner as to be effective and valid under applicable law, but in case any one or more of the provisions contained herein shall, for any reason, be held to be invalid, illegal or unenforceable in any respect, such provision shall be ineffective to the extent, but only to the extent, of such invalidity, illegality or unenforceability without invalidating the remainder of this section or any other provisions hereof. Carefully inflate the balloon (without exceeding 10 total inflations in a stent or 20 total inflations without a stent) to the appropriate pressure, to perform PTCA or post-implant dilatation of a stent per standard procedure. Make sure to continue maintaining negative pressure on the balloon between inflations. Do not exceed rated burst pressure (see Table 1). After completion of PTCA or post-implant dilatation of a stent, carefully deflate the balloon by applying negative pressure on the syringe or the inflation device, until the balloon is fully deflated. Withdraw the deflated NC Gallant TM and guidewire from the guiding catheter through the hemostatic valve. Tighten the hemostatic valve. Manufactured by: Medinol Ltd. PO Box 45026 Beck Tech Bldg. 4th floor Har-Hotzvim B, Hartom Street 8 Jerusalem 9777508 ISRAEL Authorized Representative: MedNet GmbH Borkstrasse 10 48163 Münster GERMANY Tel: +49 251 32266-0 Fax: +49 251 32266-22 Distributed by: Medinol Ltd. PO Box 58165 Building 8, 35th floor Kiryat Atidim Tel Aviv 6158101 ISRAEL Medinol Ltd 2016 May 2017 912000099-1 6