Waters Mass Spectrometry Systems

Similar documents
[ APPLICATION NOTE ] Multiresidue Analysis of Pesticides in Fruits and Vegetables Using UPLC-MS/MS APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS

European Reference Laboratory - FV. Amadeo R. Fernández-Alba

Zero Cross-talk on the TSQ Quantum

Small Molecule Science: Experimental designs for achieving ultra trace analysis

[ APPLICATION NOTE ] High Sensitivity Intact Monoclonal Antibody (mab) HRMS Quantification APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEYWORDS

Validation Report 1. CRL for Cereals and Feeding stuff National Food Institute Danish Technical University

ACHIEVEMENTS ARE LIMITED ONLY BY ASPIRATIONS.

PesticideScreener. Innovation with Integrity

European Reference Laboratory - FV. 53 rd Annual North American Chemical Residue Workshop. 18 th July 2016

Dr. Erin E. Chambers Waters Corporation. Presented by Dr. Diego Rodriguez Cabaleiro Waters Europe Waters Corporation 1

Towards High Resolution MS in Regulated Bioanalysis

SUBSTANCES AUTHORISED FOR AGRICULTURAL USE IN THE EU

Latest Innovations in LC/MS/MS from Waters for Metabolism and Bioanalytical Applications

Agilent 6410 Triple Quadrupole LC/MS. Sensitivity, Reliability, Value

Liquid Chromatograph Mass Spectrometer LCMS-8050 C146-E232A

SCS Mass Spectrometry Laboratory

Analysis of the Non-Ionic Surfactant Triton-X Using UltraPerformance Convergence Chromatography (UPC 2 ) with MS and UV Detection

Applying a Novel Glycan Tagging Reagent, RapiFluor-MS, and an Integrated UPLC-FLR/QTof MS System for Low Abundant N-Glycan Analysis

LECTURE 3. Ionization Techniques for Mass Spectrometry

[ APPLICATION NOTE ] APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEYWORDS

INTRODUCTION CH 3 CH CH 3 3. C 37 H 48 N 6 O 5 S 2, molecular weight Figure 1. The Xevo QTof MS System.

MANDATORY CANNABIS TESTING FOR PESTICIDE ACTIVE INGREDIENTS. List and limits

Rapid, Simple Impurity Characterization with the Xevo TQ Mass Spectrometer

O O H. Robert S. Plumb and Paul D. Rainville Waters Corporation, Milford, MA, U.S. INTRODUCTION EXPERIMENTAL. LC /MS conditions

EUPT-Panel. DG SANTE Mrs. Almut Bitterhof Mrs. Veerle Vanheusden ORGANISING GROUP Amadeo R. Fernández-Alba Octavio Malato Carmen Ferrer Ana Lozano

Rapid Lipid Profiling of Serum by Reverse Phase UPLC-Tandem Quadrupole MS

UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes

Chemical Analysis Business Operations Waters Corporation Milford MA

Analysis of Pesticides (II) Metribuzin & their metabolites in Rice Jun Yonekubo, Nihon Waters, JAPAN

UPLC-MS/MS Analysis of Azole Antifungals in Serum for Clinical Research

Matrix Factor Determination with the Waters Regulated Bioanalysis System Solution

2013 Waters Corporation 1

Ultra High Definition Optimizing all Analytical Dimensions

Unique Benefits of Orbitrap MS Technology for the Comprehensive Analysis of Polar and Non-polar Pesticides

EURL-FV Multiresidue Method Using QuEChERS

A NOVEL METHOD OF M/Z DRIFT CORRECTION FOR OA-TOF MASS SPECTROMETERS BASED ON CONSTRUCTION OF LIBRARIES OF MATRIX COMPONENTS.

Validation Report 8. EURL for Cereals and Feeding stuff National Food Institute Technical University of Denmark

Analysis of Testosterone, Androstenedione, and Dehydroepiandrosterone Sulfate in Serum for Clinical Research

Broad beans V2.0-07/12/2007

SYNAPT G2-S High Definition MS (HDMS) System

Agilent 6470 Triple Quadrupole LC/MS System and EMR-Lipid. The Combination for Confident Pesticide Quantitation. Christoph Mueller

Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition

Simultaneous quantitative determination and screening of pesticides using Orbitrap MS Technology. Hans Mol, Paul Zomer, Marc Tienstra

UHPLC / HPLC Columns Developed for Mass Spectrometry

Dry eye disease commonly known as atopic keratoconjunctivitis is an autoimmune disease of

Agilent s LC/MS Portfolio and Applications Examples

Mass Spectrometry at the Laboratory of Food Chemistry. Edwin Bakx Laboratory of Food Chemistry Wageningen University

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

Liquid Chromatograph Mass Spectrometer LCMS-8040 C146-E188E

Achieving the California Pesticide Regulations in Cannabis Using Optimized APCI and ESI Techniques

Biotherapeutics. Biopharmaceutical Sciences Group Waters Corporation Waters Corporation 1

for new contaminants at ultra trace level by using high resolution mass spectrometry

Amadeo R. Fernández-Alba

APPLICATIONS TN Determination of Pesticide Residues in Kale and Grapes using QuEChERS and LC-MS/MS. Introduction

The Road to Glycan Analysis Without Compromise WCBP 2015 Waters Technical Seminar Jan 27, 2015 Washington, DC

How Are We Doing? January 2014

Development of a Bioanalytical Method for Quantification of Amyloid Beta Peptides in Cerebrospinal Fluid

ION MOBILITY COUPLED TO HIGH RESOLUTION MASS SPECTROMETRY: THE POSSIBILITIES, THE LIMITATIONS

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS

Jose Castro-Perez, Henry Shion, Kate Yu, John Shockcor, Emma Marsden-Edwards, Jeff Goshawk Waters Corporation, Milford, MA, U.S. and Manchester, UK

Application Note: 425. Introduction. Goal. Experimental Conditions

Methods in Mass Spectrometry. Dr. Noam Tal Laboratory of Mass Spectrometry School of Chemistry, Tel Aviv University

ATTENTION. MRL LOR Result N/A <0.01 <0.01 N/A <0.05 <0.050 < 0.50 <0.01 <0.010 N/A <0.05 <0.05

LC/MS/MS SOLUTIONS FOR LIPIDOMICS. Biomarker and Omics Solutions FOR DISCOVERY AND TARGETED LIPIDOMICS

CHARACTERIZATION AND DETECTION OF OLIVE OIL ADULTERATIONS USING CHEMOMETRICS

SKAL:100364, ISO 14001: 2004 certified; ISO 9001: 2008 certified, Organic certified: NL-BIO-01, HACCP certified; GMP certified

PHYTO+ Certificate of Analysis:

Profiling Flavonoid Isomers in Highly Complex Citrus Juice Samples Using UPLC Ion Mobility Time-of-Flight Mass Spectrometry

Polymer Additive Analysis by EI and APCI

PTM Discovery Method for Automated Identification and Sequencing of Phosphopeptides Using the Q TRAP LC/MS/MS System

Analysis of N-Linked Glycans from Coagulation Factor IX, Recombinant and Plasma Derived, Using HILIC UPLC/FLR/QTof MS

Reducing Sample Volume and Increasing Sensitivity for the Quantification of Human Insulin and 5 Analogs in Human Plasma Using ionkey/ms

Pesticide analysis in Hops and Cannabis by GC-MS-MS

Multiresidue Analysis of 204 Pesticides in Fresh Produce Using the QuEChERS Method Followed by LC-MS/MS

SKAL:100364, ISO 14001: 2004 certified; ISO 9001: 2008 certified, Organic certified: NL-BIO-01, HACCP certified; GMP certified

Certificate of Analysis: Organic Hemp CO2 Extract Cannabinoid Profile

Method Development for the Analysis of Endogenous Steroids Using Convergence Chromatography with Mass Spectrometric Detection

Endoca Certificate of Analysis:

PerkinElmer talks at spring TCJJP Meeting Wednesday, Mar. 14, 2012

Moving from targeted towards non-targeted approaches

Fundamentals of Soft Ionization and MS Instrumentation

Rapid and Accurate LC-MS/MS Analysis of Nicotine and Related Compounds in Urine Using Raptor Biphenyl LC Columns and MS-Friendly Mobile Phases

The New 6495 Triple Quadrupole LC/MS

Probing for Packaging Migrants in a Pharmaceutical Impurities Assay Using UHPLC with UV and Mass Detection INTRODUCTION

New Mass Spectrometry Tools to Transform Metabolomics and Lipidomics

Rapid Analysis of Bisphenols A, B, and E in Baby Food and Infant Formula Using ACQUITY UPLC with the Xevo TQD

More structural information with MS n

Metabolomic fingerprinting of serum samples by direct infusion mass spectrometry

Made For Routine Food, Environment, and Forensic Testing

Simple Method (IS-MRM) to Monitor Lysophospholipids and Phospholipids During LC-MS Method Development via In-Source CID

LC-MS/MS Solutions for Comprehensive Cannabis Analysis

Vitamin D3 and related compounds by ESI and APCI

Quantification of Budesonide Using UPLC and Xevo TQ-S

LCMS-8030 Application Report. Steroids: Testosterone, Progesterone, Estradiol, Ethinylestradiol

A High Sensitivity UPLC/MS/MS Method for the Analysis of Clopidogrel and Clopidogrel Carboxylic Acid Metabolite in Human K 2 EDTA Plasma

A RAPID AND SENSITIVE ANALYSIS METHOD OF SUDAN RED I, II, III & IV IN TOMATO SAUCE USING ULTRA PERFORMANCE LC MS/MS

Ultra High Performance Liquid Chromatograph. Nexera X2 C196-E079

Chromatography. NUCLEOSHELL Bluebird RP 18 MACHEREY-NAGEL. Fast analyses under highly aqueous conditions

Mass Spectrometry Made Simple for Clinical Diagnostic Labs

Transcription:

Waters Mass Spectrometry Systems Mark N Groudas VP Americas Field Operations 25 th, July 2017 2016 Waters Corporation 1

The Science of What s Possible 2016 Waters Corporation 2

Waters MS Systems Portfolio Mass Detection Quan HRMS Research ACQUITY SQD2 QDa Xevo TQ-XS TQ-S micro TQD Xevo G2-XS QTof G2-XS Tof Vion IMS-Q-Tof SYNAPT G2-Si HDMS G2-Si MS Imaging System Universal Source Architecture: ESI UniSpray ESCi APCI ASAP APGC APPI ionkey/ms nanoesi REIMS DART DESI LAESI - LDTD HPLC UHPLC UPLC UPC 2 APGC Empower UNIFI MassLynx Progenesis 2016 Waters Corporation 3

2016 Waters Corporation 4

Xevo TQ-XS 2016 Waters Corporation 5

Xevo TQ-XS Most sensitive MS we have ever produced with market-leading performance Ultimate sensitivity from StepWave XS Tool-free probes for improved user experience Easy method transfer/accessible sensitivity with XDR detector Wider compound coverage with UniSpray 2016 Waters Corporation 6

Maximum robustness, with no compromise in performance Innovative off-axis design Ions are transferred from the source region with maximum efficiency Potential contaminants are actively filtered out Critical hardware components stay clean for longer Results are more reproducible The lab stays productive 2016 Waters Corporation 7

Key improvements to optimise performance for challenging compounds RF voltage constant improving robustness while mass switching Segmented quadrupole second stage focussed ion beam Wider profile first stage, more space for ion cloud Horizontal plates provide more controlled extraction of ions from gas flow less energetic collisions 2016 Waters Corporation 8

Improved Customer Experience Tool-free ESI and APCI probes New design: Completely tool-free Based on QDa design Takes <2 min to change the probe assembly Removed customer-assembled union at the top of the probe Helpful features included after customer feedback Probe adaptor IP-protected technology, patents in process Probe assembly 2016 Waters Corporation 9

Improved Customer Experience Xtended Dynamic Range detector Long-life photomultiplier technology Accessible sensitivity data for peptide Val-Tyr-Val UPLC/MRM ESI+, 6 orders linear dynamic range Easy method transfer to a more sensitive instrument 2016 Waters Corporation 10

Universal Ion Source Architecture Ultimate flexibility from the widest choice of ionization techniques ESI, APCI, ESCI nanoflow ESI APPI, APCI DESI APGC ASAP ionkey/ms 2016 Waters Corporation 11

One source for all UniSpray What is UniSpray? A novel ion source option exclusive to Waters Wider compound coverage Greater ionization efficiency Comparable robustness and linearity to ESI 2016 Waters Corporation 12

Waters MS Systems Portfolio Mass Detection Quan HRMS Research ACQUITY SQD2 QDa Xevo TQ-XS TQ-S micro TQD Xevo G2-XS QTof G2-XS Tof Vion IMS-Q-Tof SYNAPT G2-Si HDMS G2-Si MS Imaging System Universal Source Architecture: ESI UniSpray ESCi APCI ASAP APGC APPI ionkey/ms nanoesi REIMS DART DESI LAESI - LDTD HPLC UHPLC UPLC UPC 2 APGC Empower UNIFI MassLynx Progenesis 2016 Waters Corporation 13

Maximum robustness, with no compromise in performance Innovative off-axis design Ions are transferred from the source region with maximum efficiency Potential contaminants are actively filtered out Critical hardware components stay clean for longer Results are more reproducible The lab stays productive 2016 Waters Corporation 14

Key improvements to optimise performance for challenging compounds RF voltage constant improving robustness while mass switching Segmented quadrupole second stage focussed ion beam Wider profile first stage, more space for ion cloud Horizontal plates provide more controlled extraction of ions from gas flow less energetic collisions 2016 Waters Corporation 15

Dynamic range, speed and accuracy Innovative geometry and ion detection system, delivering: Dynamic range Sensitivity Mass Resolution Speed of analysis...simultaneously 2016 Waters Corporation 16

Vion 2016 Waters Corporation 17

Vion calculates a unique CCS value for each ion but. What is CCS? Important differentiating Characteristic of an ion Chemical Structure (mass, size) 3-dimensional Conformation (shape) Precise Physicochemical Property of an ion 2016 Waters Corporation 18

Benefits of Routine Ion Mobility Clarity cleaner mass spectra Confidence valuable CCS information for every ion System Productivity with UNIFI analytical workflows 2016 Waters Corporation 19

Routine ion mobility Seamlessly from sample to answers Just press START Simply Acquire Get to the Answers 2016 Waters Corporation 20

Benefits of Routine Ion Mobility 617.3076 m/z 236.6 Å2 Verapamil Metabolite 441.2758 m/z 289.1923 m/z 518.2235 m/z 2016 Waters Corporation 21

Benefits of Routine Ion Mobility Clarity 617.3076 m/z 236.6 Å2 Verapamil Metabolite Unlimited Product ion HDMS E 518.2235 m/z 2016 Waters Corporation 22

Vion measured CCS(N 2 ) values <2% time after time Reserpine - 609.28 m/z : 252 Å 2-0.10 % RSD LueEnk 556.27 m/z : 230 Å 2-0.15 % RSD Terfenadine 472.32 m/z : 230 Å 2-0.12 % RSD Verapamil 455.29 m/z : 211 Å 2-0.17 % RSD Sulphadimethoxine 311.08 m/z : 168 Å 2-0.15 % RSD Caffine 195.08 m/z : 136 Å 2-0.22 % RSD Data from 400 injections over 33 hours 2016 Waters Corporation 23

Acetamiprid Azoxystrobin Bromuconazole II Carbetamide Carbofuran Chlorbromuron Chloridazon (Pyrazon) Clethodim I Clethodim I fgt Clethodim II Clethodim II fgt Cyromazine DEET Demeton-S-methyl-sulfone Dichlorvos Diethofencarb fgt Disulfoton-sulfone Diuron Ethoprophos Fenamiphos sulphone Fenoxycarb Fenoxycarb fgt Fenpropimorph Fenpyroximat Flutriafol Formetanate Fosthiazate Furathiocarb Heptenophos Hexazinone Indoxacarb Isoxaben Linuron Mesotrione Metalaxyl Methabenzthiazuron Metobromuron Metolachlor Metribuzin Mevinphos trans Nitenpyram Oxadiazon pethoxamid phenthoate Pirimicarb Primicarb-desmethyl fgt* Propamocarb propargite Prosulfocarb Pymetrozine Pyraclostrobin Pyridaben Pyridaben fgt 1 Pyridate Pyriproxifen Simazine Spinosad Spirodiclofen Spiroxamine II Tebuconazole tepraloxydim Thiacloprid Thiodicarb Thiophanate-methyl Triasulfuron Triflumuron Trinexapac-ethyl Triticonazole Vamidothion % CCS Difference WIV ISP Study: SYNAPT/Vion Comparison for Pesticides between two labs UK vs Belgium Confidence 5 Synapt WIV ISP/Vion IMS Q ToF Comparison April 2015 4 3 2 1 0 Pesticide -1-2 -3-4 -5 Axis Title 2016 Waters Corporation 24

UNIFI UNIFI 1.8 Streamlined Instrument Controls Seamless Workflows Integrated Ion Mobility Tools Sophisticated Reporting UNIFI: Taking Data to Knowledge 2016 Waters Corporation 25

Waters MS Systems Portfolio Mass Detection Quan HRMS Research ACQUITY SQD2 QDa Xevo TQ-XS TQ-S micro TQD Xevo G2-XS QTof G2-XS Tof Vion IMS-Q-Tof SYNAPT G2-Si HDMS G2-Si MS Imaging System Universal Source Architecture: ESI UniSpray ESCi APCI ASAP APGC APPI ionkey/ms nanoesi REIMS DART DESI LAESI - LDTD HPLC UHPLC UPLC UPC 2 APGC Empower UNIFI MassLynx Progenesis 2016 Waters Corporation 26

Thank you and have a great Conference! 2016 Waters Corporation 27