Diagnostic Performance of MDCT for Detecting Aortic Valve Regurgitation

Similar documents
Clinical material and methods. Clinical Departments of 1 Radiology II and 2 Cardiology, Innsbruck Medical University, Innsbruck, Austria

Improvement of Image Quality with ß-Blocker Premedication on ECG-Gated 16-MDCT Coronary Angiography

Evaluation of Ascending Aortic Atherosclerosis with 16-Multidetector Computed Tomography Is Useful before Total Endoscopic Coronary Bypass Surgery

Cardiac Computed Tomography

Chapter 4. Department of Cardiology, Leiden University Medical Center, Leiden, The Netherlands. Department of Radiology,

Coronary Artery Imaging. Suvipaporn Siripornpitak, MD Inter-hospital Conference : Rajavithi Hospital

Studies with electron beam computed tomography (EBCT) Imaging

Diagnostic Accuracy of Noninvasive Coronary Angiography Using 64-Slice Spiral Computed Tomography

Improving Diagnostic Accuracy of MDCT Coronary Angiography in Patients with Mild Heart Rhythm Irregularities Using ECG Editing

Improved Noninvasive Assessment of Coronary Artery Bypass Grafts With 64-Slice Computed Tomographic Angiography in an Unselected Patient Population

Utility of CT angiography for pre-operative evaluation of robotic-assisted minimally invasive mitral valve surgery.

Coronary CT Angiography

Accuracy of Multislice Computed Tomography in the Preoperative Assessment of Coronary Disease in Patients With Aortic Valve Stenosis

Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement

General Cardiovascular Magnetic Resonance Imaging

The Final 10-Year Follow-up Results from the Bari Randomized Trial J Am Coll Cardiol (2007) 49;1600-6

Optimal image reconstruction intervals for non-invasive coronary angiography with 64-slice CT

Cardiac Imaging Tests

Aortic Valve Calcification as a Marker for Aortic Stenosis Severity: Assessment on 16-MDCT

Angio-CT: heart and coronary arteries

ECG-Gated 16-MDCT of the Coronary Arteries: Assessment of Image Quality and Accuracy in Detecting Stenoses

Non-invasive Coronary Angiography: the Role, Limitations and Future of 64-Slice Spiral Computed Tomography Coronary Angiography

A ortic stenosis (AS) is the most common valvular disease

Pushing the limits of cardiac CT. Steven Dymarkowski Radiology / Medical Imaging Research Centre

Image quality and diagnostic accuracy of 16-slice multidetector computed tomography for the detection of coronary artery disease in obese patients

, David Stultz, MD. Cardiac CT. David Stultz, MD Cardiology Fellow, PGY 6 March 28, 2006

2004;77:800 4 MSCT OF CORONARY ARTERY BYPASS GRAFTS. Results. CABG With Adequate Diagnostic Quality

Radiation Dose Reduction and Coronary Assessability of Prospective Electrocardiogram-Gated Computed Tomography Coronary Angiography

Chapter. Non-Invasive Coronary Imaging and Assessment of Left Ventricular Function using 16-slice Computed Tomography

MEDICAL POLICY. Proprietary Information of Excellus Health Plan, Inc. A nonprofit independent licensee of the BlueCross BlueShield Association

Accuracy of dual-source CT coronary angiography: first experience in a high pre-test probability population without heart rate control

Coronary artery bypass grafting has been a historically. Multislice CT Evaluation of Coronary Artery Bypass Graft Patients SYMPOSIA

Multisclice CT in combination with functional imaging for CAD. Temporal Resolution. Spatial Resolution. Temporal resolution = ½ of the rotation time

RAMA-EGAT Risk Score for Predicting Coronary Artery Disease Evaluated by 64- Slice CT Angiography

CT Imaging of Atherosclerotic Plaque. William Stanford MD Professor-Emeritus Radiology University of Iowa College of Medicine Iowa City, IA

New Cardiovascular Devices and Interventions: Non-Contrast MRI for TAVR Abhishek Chaturvedi Assistant Professor. Cardiothoracic Radiology

A Noninvasive Assessment of CAD

Low-dose CT coronary angiography in the step-andshoot mode: diagnostic performance

MEDICAL POLICY. Proprietary Information of YourCare Health Plan

Diagnostic accuracy of dual-source computed tomography in the detection of coronary chronic total occlusion: Comparison with invasive angiography

A new method for radiation dose reduction at cardiac CT with multi-phase data-averaging and non-rigid image registration: preliminary clinical trial

Recent developments in cardiac CT

The diagnostic evaluation of dual-source CT (DSCT) in the diagnosis of coronary artery stenoses

NIH Public Access Author Manuscript Acad Radiol. Author manuscript; available in PMC 2009 September 16.

Noninvasive Coronary Angiography Using Multislice Computed Tomography (MSCT) Jeffrey M. Schussler, MD, Paul A. Grayburn, MD

Sixty four slice Computed Tomography Scan (64-slice

Spiral Multislice Computed Tomography Coronary Angiography: A Current Status Report

Computed Tomography of the Coronary Arteries

Disclosure Information

The Measurement of Opening Angle and Orifice Area of a Bileaflet Mechanical Valve Using Multidetector Computed Tomography

Computed tomography (CT) and magnetic resonance

What every radiologist should know about cardiac CT: A case-based pictorial review

MEDICAL POLICY. Proprietary Information of Excellus Health Plan, Inc. A nonprofit independent licensee of the BlueCross BlueShield Association

Ultrasound. Computed tomography. Case studies. Utility of IQon Spectral CT in. cardiac imaging

Triple Rule-out using 320-row-detector volume MDCT: A comparison of the wide volume and helical modes

ADVANCED CARDIOVASCULAR IMAGING. Medical Knowledge. Goals and Objectives PF EF MF LF Aspirational

Multidetector Computed Tomography (MDCT) in Coronary Surgery: First Experiences With a New Tool for Diagnosis of Coronary Artery Disease

Multimodality Imaging of the Thoracic Aorta

Assessment of Left Ventricular Parameters Using 16-MDCT and New Software for Endocardial and Epicardial Border Delineation

SYMPOSIA. Coronary CTA. Indications, Patient Selection, and Clinical Implications

Non-invasive intravenous coronary angiography using electron beam tomography and multislice computed tomography

Diagnostic Accuracy of Computed Tomography Angiography in Patients After Bypass Grafting

DECLARATION OF CONFLICT OF INTEREST. Nothing to disclose

Indications of Coronary Angiography Dr. Shaheer K. George, M.D Faculty of Medicine, Mansoura University 2014

Zurich Open Repository and Archive

Clinical Medicine Insights: Cardiology

Dr Winnie Sze-Wun Chan. Cardiac Team Deputy Team Head Department of Radiology and Imaging Queen Elizabeth Hospital Hong Kong

Noncoronary Cardiac MDCT

Imaging in TAVI. Jeroen J Bax Dept of Cardiology Leiden Univ Medical Center The Netherlands Davos, feb 2013

ECG Gated CT Aorta in Transcatheter Aortic Valve Implantation

ROLE OF MULTISLICE COMPUTED TOMOGRAPHY IN CARDIAC IMAGING

Chapter 5 Section 1.1. Diagnostic Radiology (Diagnostic Imaging)

IMAGING the AORTA. Mirvat Alasnag FACP, FSCAI, FSCCT, FASE June 1 st, 2011

SPECT-CT: Τι πρέπει να γνωρίζει ο Καρδιολόγος

Cardiac computed tomography: indications, applications, limitations, and training requirements

Medical Policy An Independent Licensee of the Blue Cross and Blue Shield Association

Calcium scoring using 64-slice MDCT, dual source CT and EBT: a comparative phantom study

EXPERIMENTAL AND THERAPEUTIC MEDICINE 5: , 2013

Cardiac CT Techniques in Neonates (and infants)

Introduction. Cardiac Imaging Modalities MRI. Overview. MRI (Continued) MRI (Continued) Arnaud Bistoquet 12/19/03

Horizon Scanning Technology Summary. Magnetic resonance angiography (MRA) imaging for the detection of coronary artery disease

Multislice Computed Tomography in Infective Endocarditis

Pre-Procedural Imaging of Aortic Root Orientation and Dimensions

Image quality and, hence, the diagnostic value of cardiac. Imaging

Computed tomography in coronary imaging: current status

Imaging of the Cardiac Venous System: Comparison of MDCT and Conventional Angiography

Original Article Application of flash dual-source CT at low radiation dose and low contrast medium dose in triple-rule-out (tro) examination

Impact of SSF on diagnostic performance of coronary CT angiography within one heart beat in patients with high heart rate using a 256-row detector CT

SYNTAX III REVOLUTION Trial Press briefing conference. Prof. Patrick W. Serruys MD, PhD Principal Investigator Imperial College of London

X-ray coronary angiography is considered the diagnostic

Coronary artery disease remains

Electron Beam CT versus 16-slice Spiral CT: How Accurately Can We Measure. Coronary Artery Calcium Volume?

Evaluation of Robotic Coronary Surgery With Intraoperative Graft Angiography and Postoperative Multislice Computed Tomography

Recent Advancement of Cardiac CT

Non-invasive coronary angiography with high resolution multidetector-row computed tomography

Cardiac CT - Coronary Calcium Basics Workshop II (Basic)

Covered Indications. Evaluation of chest pain syndrome uninterpretable or equivocal stress test (exercise, perfusion, or stress echo)

b. To facilitate the management decision of a patient with an equivocal stress test.

Impact of 64-Slice Multidetector Computed Tomography on Other Diagnostic Studies for Coronary Artery Disease

Scientific Exhibit. Authors: D. Takenaka, Y. Ohno, Y. Onishi, K. Matsumoto, T.

Transcription:

Feuchtner et al. MDCT for ortic Valve Regurgitatio n Detection Cardiac Imaging Original Research C M E D E N T U R I C L I M G I N G JR 2006; 186:1676 1681 0361 803X/06/1866 1676 merican Roentgen Ray Society Y O Gudrun M. Feuchtner 1 Wolfgang Dichtl 2 Thomas Schachner 3 Silvana Müller 2 mmar Mallouhi 1 Guy J. Friedrich 2 Dieter zur Nedden 1 F Feuchtner GM, Dichtl W, Schachner T, et al. Keywords: aortic valve disease, CT coronary angiography, CT coronary arteriography, heart, MDCT DOI:10.2214/JR.05.0967 Received June 7, 2005; accepted after revision September 18, 2005. 1 Clinical Department of Radiology II, Innsbruck Medical University, nichstr. 35, -6020 Innsbruck, ustria. ddress correspondence to G. M. Feuchtner (Gudrun.Feuchtner@uibk.ac.at). 2 Clinical Department of Cardiology, Innsbruck Medical University, Innsbruck, ustria. 3 Clinical Department of Cardiac Surgery, Innsbruck Medical University, Innsbruck, ustria. Diagnostic Performance of MDCT for Detecting ortic Valve Regurgitation OJECTIVE. This study evaluates whether ECG-gated 16-MDCT coronary angiography provides a reliable imaging technique for detecting aortic regurgitation (R). SUJECTS ND METHODS. We examined 71 patients prospectively with 16-MDCT angiography using retrospective ECG gating during the mid-to-end diastolic phase. visible central valvular leakage area was considered as a diagnostic criterion for R. The central valvular leakage area was quantified in patients with positive transthoracic echocardiography (TTE). We compared 16-MDCT to Doppler TTE, the accepted diagnostic standard based on semiquantitative regurgitation jet analysis (grade 0 3+ for mild, moderate, and severe). RESULTS. The overall sensitivity of 16-MDCT for the identification of patients with R was 81%. The specificity was 91%, the negative predictive value was 70%, and the positive predictive value was 95%. Of the 71 patients, 48 had R determined by TTE, and 16-MDCT correctly detected R in 39 of those 48 patients. The sensitivity of 16-MDCT for the detection of patients with moderate and severe R (grade 1.5+) was 95%, and the specificity was 96% (20 of 21 patients). The sensitivity of 16-MDCT for identification of patients with mild R (grade 1+) was 70%, and the specificity was 92% (19 of 27 patients). Quantification of the central valvular leakage area was not possible in 50% of cases with R by TTE because of valve calcifications. CONCLUSION. Sixteen-MDCT coronary angiography provides an accurate, noninvasive imaging technique to detect moderate and severe aortic regurgitation (grade 1.5+). However, severe valve calcifications and mild R limit its results. ixteen-mdct is a highly accurate S imaging method for detecting significant coronary artery stenosis [1 4]. lso, 16-MDCT shows promising results in assessing coronary bypass graft patency [5, 6]. The comorbidity of aortic valve pathologies, such as degenerative aortic valve stenosis with concomitant aortic regurgitation (R), is relatively high in patients with coronary artery disease. With 16-MDCT, retrospective ECG gating is used, which offers image reconstruction at any time during the cardiac cycle. The aortic valve leaflets are usually closed tightly during diastole. ccordingly, in the presence of R, a central valvular leakage area might be detected using 16-MDCT. This study assesses the clinical accuracy of 16-MDCT in the identification of R in patients who undergo 16-MDCT coronary angiography, based on the visibility of a central valvular leakage area, compared with the currently accepted diagnostic standard, transthoracic echocardiography (TTE). Subjects and Methods Study Population total of 71 patients (55 men and 16 women with a mean age of 65 years; range, 39 82 years) were examined between October 2003 and pril 2005. Patient exclusion criteria were renal dysfunction and other contraindications to the iodine contrast agent (e.g., known allergy). The institutional review board approved studies on cardiac 16-MDCT in patients with degenerative aortic valve stenosis (n = 48) and in patients before or after totally endoscopic coronary bypass surgery (n = 13). The remaining patients underwent cardiac 16-MDCT for follow-up of ascending aortic aneurysm and/or evaluation of clinically suspected coronary artery disease (n =8), ascending aortic dissection with coronary ostium involvement (n = 1), or after cardiac surgery accompanied by atypical chest pain (n = 1). Written informed consent was obtained from all patients. MDCT Examination Technique ll examinations were performed using a 16- MDCT scanner (Sensation 16, Siemens Medical 1676 JR:186, June 2006

MDCT for ortic Valve Regurgitation Detection Fig. 1 ortic valve (normal finding) appeared closed in two patients without aortic regurgitation during mid-to-late diastole., 67-year-old man with degenerative aortic stenosis. Tricuspid valve morphology and moderate valve calcifications (white) (gatston calcium score [CS]: 1997.1) were displayed by using volume-rendering technique (VRT) slab., 75-year-old woman with degenerative aortic stenosis. icuspid valve morphology and moderate valve calcifications (white) (CS: 2018.3) are shown by applying 3D VRT slab. VRT was preferred to show localization and extent of valve calcifications, which can provide interesting information to cardiac surgeons. Fig. 2 47-year-old man with degenerative aortic stenosis., Concomitant moderate aortic regurgitation (grade 2+) is shown on cross-sectional transverse plane by applying multiplanar reformation (multiplanar reconstruction). ortic valve leaflets did not close up tightly at diastole, and central triangular valvular leakage was revealed., Central aortic regurgitation area (R) was circled with digital caliper and calculated in cm 2. Valve calcifications (arrow) might limit accurate quantification of aortic regurgitation area. RCC = right coronary cusp, LCC = left coronary cusp, NCC = noncoronary cusp. JR:186, June 2006 1677

Feuchtner et al. Solutions) [7]. Collimation was 12 0.75 mm, table translation speed was 6.7 mm/sec, gantry rotation time was 0.42 sec, tube current was 400 500 ms, tube voltage was 120 kv, and the effective radiation dose ranged between 6.7 and 13 msv [8]. bolus of 100-mL iodine contrast agent (iodixanol, Visipaque 320, mersham Health) was injected IV into an antecubital vein at a flow rate of 3 to 4 Fig. 3 56-year-old woman with moderate aortic regurgitation (grade 2+) without valve calcifications. Note central triangular valvular leakage area. Fig. 4 68-year-old man who had previous coronary bypass surgery and who underwent 16- MDCT angiography because of recurrent angina pectoris., Volume-rendering technique displays coronary bypass grafts: left internal thoracic artery and venous aortocoronary bypass graft (white arrow); right coronary artery with heavy calcifications and calcifying plaque at ascending aorta (black arrow) (white spots)., Moderate aortic regurgitation (grade 2+) with valve calcifications (white) was detected by applying multiplanar reconstruction. Note that aortic valve is prone to calcify in patients with coronary artery disease. ml/sec using a power injector (Ulrich Medizintechnik). Scan delay was calculated by measuring CT attenuation values at the ascending aorta using dedicated software (DynEva, Siemens Medical Solutions), after injecting a 20-mL test bolus of contrast agent. The time point of the highest CT attenuation was taken as the scan delay. Scanning was performed during a single inspiratory breath-hold of 20 to 28 sec. β-blocker was injected IV (1 5 mg metoprolol tartrate, eloc, Schering) before the examination if the heart rate was greater than 75 beats per minute (bpm). Images were reconstructed with a smooth convolution kernel (10 f), at an increment of 0.6, 1- mm effective slice thickness, image matrix 512 512, field of view 130 190 mm, and by using retrospective ECG gating at mid-to-end diastole (60 80% of R-R interval). Images were then transferred to a dedicated offline computer workstation (Leonardo, Siemens Medical Solutions). The aortic valve was reconstructed using multiplanar reformation (multiplanar reconstruction) and volume-rendering technique. ortic valve leaflets were evaluated for whether a tight closure ( Mercedes-star appearance) (Fig. 1) or an area of central valvular leakage (Figs. 2 7), suggesting aortic valve regurgitation, was noted by two independent observers. The central valvular leakage area was circled with a digital caliper and computed in cm 2 (Fig. 2). ortic valve calcifications were quantified on unenhanced 16-MDCT (collimation 16 1.5 mm, table feed 3.8 mm/rotation, gantry rotation 0.5 sec, 130 ms, 120 kv, increment 3, 3-mm effective slice thickness, medium convolution kernel [35 f], retrospective ECG gating at 60 80% of R-R interval) using dedicated coronary calcium scoring software (syngo, Leonardo, Siemens Medical Solutions). 1678 JR:186, June 2006

MDCT for ortic Valve Regurgitation Detection Transthoracic Echocardiography ll measurements were performed using a standard sonography system (Sequoia 256, cuson-siemens) equipped with a 3.5/1.75 MHz transducer. ortic valve regurgitation was assessed semiquantitatively by calculation of jet area/jet length, proximal jet width, and the pressure half-time method [7]. The severity of R was classified as grade 0 3+ (mild, moderate, severe) [9]. Mean and maximum transvalvular pressure gradients were measured to assess whether aortic valve stenosis was present. Statistical nalysis Statistical analysis was performed using SPSS software (V8.0, SPSS). The sensitivity, specificity, negative predictive value (NPV), and positive predictive value (PPV) of 16-MDCT for identifying patients with R were calculated. Interrater agreement was calculated by using weighted Cohen s kappa value. n unpaired Student s t test was used to determine the significance of differences in aortic valve calcification scores. The correlation between the severities of R as measured by 16- MDCT and by TTE was determined by Spearman s rank correlation coefficient. Results The overall sensitivity of 16-MDCT for detection of patients with R was 81% (95% confidence interval [CI], 68 89), the specificity was 91% (95% CI, 73 97), NPV was 70% (95% CI, 52 83), and PPV was 95% (95% CI, 83 98). Forty-eight of 71 patients had R as determined by TTE. 16- MDCT correctly identified 39 of the 48 patients with R. The severity of R was classified as moderate or severe (grade 1.5+) in 21 patients and as mild (grade 1.0+) in 27 patients with TTE. Twenty of the 21 patients who had R of grade 1.5+ were detected with 16- MDCT (sensitivity 95% [95% CI, 77 99], specificity 96% [95% CI, 86 98], PPV 90% [95% CI, 72 97], and NPV 97% [95% CI, 89 99]). Sixteen-MDCT identified 19 of 27 patients who had mild R grade 1+ as determined by TTE (sensitivity 70% [95% CI, 51 84], specificity 92% [95% CI, 75 97]). Interrater agreement was 0.96 ± 0.12 (weighted kappa value). Two patients were false-positive on 16-MDCT examination; both had valve calcifications. Quantification of the central valvular leakage area (aortic regurgitation area [R]) by 16-MDCT was performed in 24 (50%) of the 48 patients. The mean R was 0.41 cm 2 ± 0.47 (Table 1). In the remaining patients, quantification of R was not performed. In the opinion of both observers, circling R was judged as probably inaccurate because valve calcifications located at leaflets margins caused artifacts that projected into the R. The R as measured by 16-MDCT was correlated with the graduation of R severity (grade 0 3+) by TTE (r =0.95, p < 0.001, Spearman s rank correlation). significant difference in aortic valve gatston calcium score (CS) (p = 0.004, unpaired Student s t test) was noted between the patients in whom quantification of R was possible and not possible (CS: 1655.9 ± 1672 vs 3796.9 ± 2684). The mean heart rate in our study population was 64 bpm ± 12.6 (minimum 44 bpm, maximum 78 bpm). Six patients had a right ventricular pacemaker; the other patients were in sinus rhythm. Fig. 5 57-year-old man with ascending aortic aneurysm., scending aortic aneurysm, which is frequently associated with aortic regurgitation, is shown with multiplanar reconstruction (left coronal oblique view)., Cross-sectional image of bicuspid valve shows central valvular leakage corresponding to moderate aortic regurgitation (grade 2+) without valve calcifications. JR:186, June 2006 1679

Feuchtner et al. Fig. 6 48-year-old man who underwent 16-MDCT coronary angiography for suspected coronary artery disease. Mild aortic regurgitation (grade 1+) was incidental finding and appeared spotlike, which may be easy to miss. Discussion This study shows that 16-MDCT accurately identifies moderate and severe aortic regurgitation (grade 1.5+) in patients undergoing 16- MDCT coronary angiography, irrespective of the extent of valve calcifications. In contrast, the technique was less sensitive in detecting patients with mild R (grade 1.0+), which might be explained by the fact that the spatial resolution of TTE is still superior to 16- MDCT. Furthermore, TTE is a technically different approach, based on Doppler flow analysis. However, the new 64-MDCT scanners provide higher spatial resolution than 16- MDCT and therefore improve aortic valve imaging. In addition, dedicated 4D cardiac postprocessing software is now available for 64- MDCT cardiac systems, facilitating the assessment of aortic valve dynamics during the cardiac cycle. The aortic valve is usually closed during diastole. Our data show in the presence of R, 16-MDCT can detect a central valvular leakage area because the aortic valve leaflets do not close up tightly during diastole. This aortic valve regurgitation area could be quantified in 50% of our patients. However, quantification of R was evaluated as probably inaccurate and therefore was not performed in the remaining patients because of the presence of severe valve calcifications located at cusp margins, which caused blurring, and partial volume or beam-hardening artifacts that projected into the R. Clinical pplications Concomitant R is frequently present in patients with ascending aortic aneurysm or degenerative aortic valve stenosis. Degenerative aortic stenosis is the second most common cardiovascular disease with a prevalence of 2 7% in Western European and North merican people who are older than 65 years [10]. Coronary artery disease comorbidity in patients with degenerative aortic stenosis is relatively high because the pathomechanisms involved are similar and because coronary risk factors influence the progression of aortic stenosis [11, 12]. Therefore, radiologists and cardiologists interpreting coronary and ascending aortic 16-MDCT angiograms should evaluate the aortic valve simultaneously for concomitant R. lso, R may develop secondarily either to rheumatic fever or to endocarditis, or may be congenital in patients with bicuspid valves. These patients may be young and may have a Fig. 7 66-year-old man with known degenerative aortic stenosis accompanied by severe valve calcifications (gatston score: 10,107.2) and mild aortic regurgitation as assessed with transthoracic echocardiography. 16-MDCT could not detect aortic regurgitation because heavy valve calcifications located at valve leaflets margins prevented accurate display of central valvular leakage area. low pretest probability of coronary artery disease. Patients with severe R require surgical treatment [10] and preoperative evaluation of coronary artery disease, which is currently routinely performed with cardiac catherization. ccordingly, these patients would be a target group for replacement of cardiac catheterization with 16- and 64-MDCT coronary angiography. However, better evaluation of the diagnostic performance of 16- and 64-MDCT coronary angiography for use with potential valve surgery patients can be done when results of ongoing clinical trials become available. In contrast to cardiac catheterization, MDCT allows a detailed visualization of aortic valve morphology [13]. For example, the extent and localization of valve calcifications can be displayed, and differentiation between tricuspid and bicuspid valve shapes is feasible (Fig. 1), which may provide interesting information that will help the cardiac surgeon select the surgical approach. Differentiation between bicuspid and tricuspid valve morphology may be difficult with TTE. lso, 16-MDCT allows detection of severe aortic regurgitation in a patient with acute ascending aortic dissection, which is important information to have before per- 1680 JR:186, June 2006

MDCT for ortic Valve Regurgitation Detection TLE 1: Patient Characteristics and Quantification of ortic Valve Regurgitation rea by MDCT Patient ge (yr) History TTE Grade MDCT R (cm 2 ) MDCT CS 1 49 Endocarditis 3+ 1.79 0 2 39 Endocarditis 2+ 0.43 0 3 67 Typ dis 3+ 0.86 N 4 75 3+ 0.58 0 5 55 2+ 0.83 0 6 50 3+ 1.52 0 7 73 2+ 0.75 0 8 47 S 2+ 0.4 2492.1 9 72 S 2+ 0.52 2446.8 10 68 S 1.5+ 0.13 6208.1 11 53 S 1+ 0.07 1407.2 12 52 S 1+ 0.05 1852.6 13 71 S 2+ 0.36 5351.4 14 82 S 2+ 0.35 2887.8 15 48 S 2+ 0.48 3067.2 16 53 S 1+ 0.05 1868 17 77 S 0.5+ 0.03 1778.7 18 75 S 1.5+ 0.11 1635.0 19 76 S 1.5+ 0.12 1885.4 20 77 S 1+ 0.10 1850.0 21 62 CD 1+ 0.04 0 22 78 S 1+ 0.05 1871.3 23 68 S 1+ 0.07 1484 24 52 Unknown 1+ 0.05 0 Note = ascending aortic aneurysm, CS = aortic valve calcification score (gatston score), R = aortic regurgitation area, S = aortic stenosis, CD = coronary artery disease, N = not assessable, TTE = transthoracic echocardiography, Typ dis = dissection of the ascending aorta (Stanford classification). forming emergency surgical repair [14], supporting the use of 16- and 64-MDCT in patients with acute chest pain. In conclusion, 16-MDCT provides a noninvasive, reliable imaging technique to identify moderate and severe aortic regurgitation of grade 1.5+ in patients undergoing 16- MDCT coronary angiography. oth 16- and 64-MDCT might also allow a new noninvasive, preoperative diagnostic approach in patients with planned cardiac surgery in the future. References 1. Hoffmann M, Shi H, Schmitz, et al. Noninvasive coronary angiography with multislice computed tomography. JM 2005; 293:2471 2478 2. Nieman K, Cademartiri F, Lemos P, et al. Reliable noninvasive coronary angiography using submillimeter multislice spiral computed tomography. Circulation 2002; 106:2051 2054 3. Mollet NR, Cademartiri F, Krestin GP, et al. Improved diagnostic accuracy with 16-row multi-slice computed tomography coronary angiography. J m Coll Cardiol 2005; 45:128 132 4. Kuettner, Kopp, Schroeder S, et al. Diagnostic accuracy of multidetector computed angiography in patients with angiographically proven coronary artery disease. J m Coll Cardiol 2004; 43:831 839 5. Nieman K, Pattynama PMT, Rensing J, et al. Evaluation of patients after coronary artery bypass surgery: angiographic assessment of grafts and coronary arteries. Radiology 2003; 229:749 756 6. Schlosser T, Konorza T, Hunold P, et al. Noninvasive visualization of coronary artery bypass grafts using 16-detector row computed tomography. J m Coll Cardiol 2004; 44:1224 1229 7. Flohr T, ruder H, Stierstorfer K, et al. New technical developments in multislice CT. 2. Sub-millimeter 16- slice scanning and increased gantry rotation speed for cardiac imaging. Rofo 2002; 174:1023 1027 8. Hunold P, Vogt FM, Schmermund, et al. Radiation exposure during cardiac CT: effective doses at multi-detector row CT and electron-beam CT. Radiology 2003; 226:145 152 9. uck T, Plicht, Wenzel RR, Hunold P, Erbel R. Echocardiography flow quantification for determining the severity of heart valve insufficiency [in German]. Herz 2002; 27:254 268 10. onow R, Carabello, de Leon C Jr, et al. Guidelines for the management of patients with valvular heart disease: a report of the merican College of Cardiology/merican Heart ssociation Task Force on Practice Guidelines (Committee on Management of Patients with Valvular Heart Disease). Circulation 1998; 98:1949 1984 11. Stewart F, Siscovick D, Lind K, et al. Clinical factors with calcific aortic valve disease. J m Coll Cardiol 1997; 29:630 634 12. Pohle K, Maffert R, Ropers D, et al. Progression of aortic valve calcification: association with coronary atherosclerosis and cardiovascular risk factors. Circulation 2001; 104:1927 1932 13. Willmann JK, Weishaupt D, Lachat M, et al. Electrocardiographically gated multi-detector CT for assessment of valvular morphology and calcifications in aortic stenosis. Radiology 2002; 225:120 128 14. Feuchtner GM, Schachner T, Friedrich G, et al. cute aortic dissection with coronary ostium involvement and aortic valve regurgitation: threedimensional visualization with multislice computed tomography. J Thorac Cardiovasc Surg 2005; 130:587 588 JR:186, June 2006 1681