Maximize Control. Minimize Migration.

Similar documents
Clinical Performance of GORE VIABIL Biliary Endoprosthesis in the Treatment of Malignant Strictures

Biliary Metal Stents MAKING A DIFFERENCE TO HEALTH

Durable outcomes. Proven performance.

Covered biliary stents with proximal bare stent extension for the palliation of malignant biliary disease: can we reduce tumour overgrowth rate?

ACUTE CHOLANGITIS AS a result of an occluded

Review Article Covered Stents versus Uncovered Stents for Unresectable Malignant Biliary Strictures: A Meta-Analysis

Expandable stents in digestive pathology present use in an emergency hospital

All-In-One. Iliac Branch System. PER F ORM ANC E b y d e s i g n ILIAC BRANCH ENDOPROSTHESIS

PLACE YOUR TRUST. in Boston Scientific Metal Stents IN THOUSANDS OF PHYSICIANS LIKE YOU IN PIONEERING DESIGNS IN CLINICAL EVIDENCE IN EXPERIENCE

Gastric / EUS Metal Stents

A Guide for Patients Living with a Biliary Metal Stent

THE THE MORE MORE NATURAL APPROACH TO OPTIMAL FIT

The first stents designed for use in the biliary tree and

Paola Figueroa-Barojas, Mihir R. Bakhru, Nagy A. Habib, Kristi Ellen, Jennifer Millman, Armeen Jamal-Kabani, Monica Gaidhane, and Michel Kahaleh

Evaluation of a 12-mm diameter covered self-expandable end bare metal stent for malignant biliary obstruction

Jennifer Hsieh 1, Amar Thosani 1, Matthew Grunwald 2, Satish Nagula 1, Juan Carlos Bucobo 1, Jonathan M. Buscaglia 1. Introduction

We Catch. What Others Miss

Colonic Metal Stents MAKING A DIFFERENCE TO HEALTH

Endoscopic Management of Biliary Strictures. Sammy Ho, MD Director of Pancreaticobiliary Services and Endoscopic Ultrasound Montefiore Medical Center

A tale of two LAMS: a report of benign tissue ingrowth resulting in recurrent gastric outlet obstruction

STRICTURES OF THE BILE DUCTS Session No.: 5. Andrea Tringali Digestive Endoscopy Unit Catholic University Rome - Italy

INTRODUCTION. Key Words: Cholestasis, extrahepatic; Stents; Cholangiography; Endoscopic retrograde. ORiginal Article

WallFlex Stents Technique Spotlights

WallFlex Biliary Metal Stents

Indications for use. Contraindications within the United States

Clinical Study Covered Metal Stenting for Malignant Lower Biliary Stricture with Pancreatic Duct Obstruction: Is Endoscopic Sphincterotomy Needed?

Risk of Post-ERCP Pancreatitis after placement of Covered versus Uncovered Self-Expandable Biliary Metal Stents: A Systematic Review and Meta-Analysis

Access More Patients. Customize Each Seal.

WallFlex Biliary RX Partially Covered Stent System Prescriptive Information

Стенты «Ella-cs» Уважаемые коллеги! Высылаем очередной выпуск «Issue of ELLA Abstracts»

Mechanical Properties of the GORE TIGRIS Vascular Stent

Percutaneous Palliation of Pancreatic Head Cancer: Randomized Comparison of eptfe/fep Covered Versus Uncovered Nitinol Biliary Stents

Early Infectious Complications of Percutaneous Metallic Stent Insertion for Malignant Biliary Obstruction

Double-Stent System with Long Duodenal Extension for Palliative Treatment of Malignant Extrahepatic Biliary Obstructions: A Prospective Study

Review Article Fully Covered Self-Expandable Metal Stents for Treatment of Both Benign and Malignant Biliary Disorders

Introduction What Causes Peripheral Vascular Disease? How Do Doctors Treat Peripheral Vascular Disease?... 9

Approach to the Biliary Stricture

A Novel Partially Covered Self-Expandable Metallic Stent with Proximal Flare in Patients with Malignant Gastric Outlet Obstruction

Trimming of a Broken Migrated Biliary Metal Stent with the Nd:YAG Laser

Partially Covered Metal Stents May Not Prolong Stent Patency Compared to Uncovered Stents in Unresectable Malignant Distal Biliary Obstruction

Introduction 3. What is Peripheral Vascular Disease? 5. What Are Some of the Symptoms of Peripheral Vascular Disease? 6

Self Expandable Metallic Stents in Malignant Biliary Obstruction: Safety and Efficacy

RX Biliary System. Start

WallFlex Biliary RX Fully Covered Stent System Prescriptive Information

GORE EXCLUDER AAA Endoprosthesis ANNUAL CLINICAL UPDATE OCTOBER Section I Clinical experience. Section II Worldwide commercial experience

Vascular V12. Covered Stent. The New Standard of Care

Owen Dickinson. Consultant in Endoscopy & Interventional Radiology. Upper GI Stenting. Rotherham Foundation Trust

AXIOS Stent and Electrocautery Enhanced Delivery System. Quick Reference Guide

GORE EXCLUDER AAA Endoprosthesis demonstrates long-term durability. Michel Reijnen Rijnstate Hospital Arnhem, The Netherlands

Minneapolis, MN 55455, USA 9 University of Colorado Boulder, Campus Box F735, Anschutz Inpatient Pavilion (AIP), S/M Gastroenterology,

Biliary Strictures: the Long and the Short of It. Willis Parsons, M.D. Medical Director of GI Lab Northwest Community Hospital Arlington Heights, IL

Allium Trans-hepatic Biliary Stent (BIS)

Double endoscopic bypass for gastric outlet obstruction and biliary obstruction

Proven Performance Through Innovative Design *

My personal experience with INCRAFT in standard and challenging cases

7/11/2017. We re gonna help a lot of people today. Biliary/Pancreatic Endoscopy. AGS July 1-2, Kenneth M. Sigman, MD

LOWERING THE PROFILE RAISING THE BAR

A LEADER IN ADVANCED ENDOSCOPY AND HEPATOBILIARY SURGERY

Intraluminal Brachytherapy after Metallic Stent Placement in Primary Bile Duct Carcinoma 1

Endoscopic stent placement throughout the gastrointestinal tract van den Berg, M.W.

Interventional Endoscopy in PB Malignancy

GORE TAG Thoracic Endoprosthesis ANNUAL CLINICAL UPDATE SEPTEMBER 2018 Abstract. Section I GORE TAG Device Clinical experience. Section II Conformable

The Ideal Venous Stent and Early Results from Venous Stent Trials PNEC, Seattle

EGIS BILIARY STENT. 1. Features & Benefits 2. Ordering information 3. References

thoracic stent graft system Smallest delivery profile as from 20 F

Endoscopic stenting in bile duct cancer increases liver volume

Practical applications and learning curve for EUS-guided hepaticoenterostomy: results of a large single-center US retrospective analysis

Advanced Bronchoscopy

Clinical Study Efficacy of the New Double-Layer Stent for Unresectable Distal Malignant Biliary Obstruction: A Single-Center Retrospective Study

Right Choice for Right Angles

Endoscopic management of malignant biliary stenosis. Update and highlights for standard clinical practice

Christian Wissgott MD, PhD Assistant Director, Radiology Westküstenkliniken Heide

NIRxcell CoCr Coronary Stent System

AERO DV Tracheobronchial Direct Visualization Stent System

MAXIMIZE RADIAL SOLUTIONS TO PERIPHERAL CHALLENGES

Endoscopic Stent Placement in the Palliation of Malignant Biliary Obstruction

Watchman. Left Atrial Appendage Closure Device. Uniquely engineered for the LAA 1-3 with proven safety and longterm efficacy. 4-8

Instructions for Use Cordis PRECISE PRO Rx Nitinol Stent System

Expanding to every demand: The GORE VIABAHN VBX Stent Graft

Clinical Study Multicenter Randomized Trial of 10-French versus 11.5-French Plastic Stents for Malignant Biliary Obstruction

ORIGINAL ARTICLE: Clinical Endoscopy

Metal versus plastic stents for malignant biliary obstruction: An update meta-analysis

creating stability a bess group company Stents for Gastroenterology

Challenges with Complex Anatomies Advancing Care in Endovascular Aortic Treatment

Endoscopic Management of the Iatrogenic CBD Injury

Endoscopic biliary self-expandable metallic stent in malignant biliary obstruction with or without sphincterotomy: systematic review and meta-analysis

6/17/2016. ERCP in June 26, Kenneth M. Sigman, M.D. Birmingham Gastroenterology Associates

Asia-Pacific Endoscopic Retrograde Cholangiopancreatography (ERCP) Procedures Outlook to 2020

North Medical Endoscopic Biliary Stent (BilS)

Primary patency of percutaneously inserted self-expanding metallic stents in patients with malignant biliary obstructionhpb_

Colonic stenting anno 2014

ORIGINAL PAPERS. Endoscopic ultrasound-guided choledochoduodenostomy after a failed or impossible ERCP

Cholangiocarcinoma (Bile Duct Cancer)

Talent Abdominal Stent Graft

The Endoscopic Management of PSC

Zenith Alpha T HORACIC ENDOVASCULAR GRAFT

Lumen Apposing Metal Stents: Expanding the Role of the Interventional Endoscopist. Alireza Sedarat, MD UCLA Division of Digestive Diseases

Research Article Endoscopic Ultrasound-Guided Biliary Drainage Using Self-Expandable Metal Stent for Malignant Biliary Obstruction

Endoscopic Retrograde Cholangiopancreatography (ERCP)

The Challenge of Accurately Stenting Aorto-Ostial Lesions

Transcription:

Maximize Control. Minimize Migration. New SHORT WIRE Delivery System SHORT W IRE BILIARY ENDOPROSTHESIS

Improved treatment of biliary strictures The self-expanding, fully covered metal stent is intended for palliation of malignant strictures in the biliary tree. The GORE VIABIL Short Wire Biliary Endoprosthesis is the only fully covered metal stent with anti-migration technology proven to minimize the risk of reintervention. Additionally, it offers substantiated evidence in studies that demonstrate sustained long-term patency. The precision you expect. Non-foreshortening * stent design and short wire delivery system provide optimal deployment positioning. The outcomes you demand. Designed to reduce the risk of migration and premature obstruction, while sustaining long-term patency. The assurance you can count on. With a 0.2% average reported migration rate 1, GORE VIABIL Short Wire Biliary Endoprosthesis is backed by a device replacement program if a migration occurs. 2 We re so confident, we now offer an ANTI-MIGRATION ASSURANCE PROGRAM Replacement if a device migrates within one full year post implantation ** *If deployed as instructed, the endoprosthesis will not appreciably foreshorten. **See back for the details of the assurance program.

Demonstrated low migrations 1 Fully covered anchoring fins Securely holds the device within the duct to minimize the risk of migration, with a reported 0 1.4% migration rate range outperforming BOSTON SCIENTIFIC WALLFLEX Biliary RX Fully Covered Stent migration rates ranging up to 0 13%. 1 Precise delivery New short wire delivery system Combined short wire delivery system and stent flexibility provides accurate delivery with optimal positioning and deployment. Optimal Conformability 2 Nitinol Wire based stent design Optimal balance of Radial and Axial force provides the right fit and flexibility to help prevent migration and sludge formation. 3,4 Prevents tissue ingrowth and promotes conformability 3 Durable, non-porous FEP / eptfe liner Prevents tissue ingrowth and promotes conformability. Proven highest patency helps provide a high standard of palliative care for your patients. 5,6 Non-foreshortening design for precision you can count on. During delivery: Unlike other stents, eliminates repositioning associated with typical push / pull delivery Will not appreciably change in length GORE VIABIL Short Wire Biliary Endoprosthesis 1 2 BOSTON SCIENTIFIC WALLFLEX Biliary RX Fully Covered Stent 3

Unique combination for the treatment of biliary obstruction Anti-migration design Unique anti-migration design features atraumatic anchoring fins to help minimize the risk of migration and mitigate clinical challenges. MIGRATION RATE COMPARISON 1 Based on 23 papers published from 2002 to 2015. 0 1.4% (0.2% weighted average) GORE VIABIL Biliary Endoprosthesis 0.0% Bezzi M et al. 0.0% Fanelli F et al. 0.0% Hatzidakis A et al. 0.0% Krokidis M et al. 1.4% Bakhru M et al. 0.0% Irurzun J et al. 0.0% Krokidis M et al. 0.0% Marzio A et al. 0.0% Scheer F et al. 0.0% Schoder M et al. 0.0% Van Steenbergen W 0.0% Zurstrassen CE et al. BOSTON SCIENTIFIC WALLFLEX Biliary RX Fully Covered Stent Nakai et al. 0.0% Kitano et al. 0.0% Kahaleh et al. 1.5% Petersen et al. 1.7% Ogawa et al. 2.8% Korenblit et al. 3.9% Sampaziotis et al. 4.7% Average reported migration rate is 0.2%. 1 Siddiqui et al. 5.0% Lee et al. 7.0% 0 13% (4.6% weighted average) Chedid et al. 8.8% We re so confident, we now offer an ANTI-MIGRATION ASSURANCE PROGRAM Replacement if a device migrates within one full year post implantation Ryozawa et al. 13.0%

Preferred balance of Axial and Radial forces* conform to duct anatomy According to studies by Isayama et al., 2012, stent migration and sludge formation is related to the device conformability in the bile duct, which is influenced by the device s axial force (Af).3 A balance of low axial force and moderate radial force (Rf) is preferred for optimal performance.4 STRAIGHTENING AXIAL FORCE Preferred combination 14 GORE VIABIL Biliary Device (ø10mn) GORE VIABIL Biliary Device (ø8mn) BOSTON SCIENTIFIC WALLFLEX Biliary RX Stent (ø10mn) BOSTON SCIENTIFIC WALLFLEX Biliary RX Stent (ø8mn) Radial Force (N) 12 10 8 6 4 2 Low axial force 0 GORE VIABIL Biliary Endoprosthesis is the preferred combination of low Af and moderate Rf to minimize risk of migration, conforming naturally to the duct anatomy.4 TRAIGHTENING AXIALbile FORCE High axial force 0 20 40 60 80 100 120 Axial Force (mn) Compared to the BOSTON SCIENTIFIC WALLFLEX Biliary RX Fully Covered Stent, the GORE VIABIL Biliary Endoprosthesis has low Af and moderate Rf, the preferred combination for reducing migration and achieving higher patency.4 SEMS with high Af do not conform well in the curved bile duct, increasing the risk of stent migration. Additionally, the duct tends to kink at the proximal edge of the stent, causing sludge formation or cholangitis.3 Higher primary patency Clinical performance demonstrates GORE VIABIL Biliary Endoprosthesis maintains higher primary patency than the leading competitor at 3, 6, and 12-months.5,6 Improved long-term patency can mean an improved quality of life for patients. 100% 100% 96.2% 98.3% 90% 80% 70% 60% 84.3% 76.5% GORE VIABIL Biliary Endoprosthesis BOSTON SCIENTIFIC WALLFLEX Biliary RX Fully Covered Stent 63.5% 50% 3 months * Axial force is the recovery force that leads to straightening after being bent, while Radial force maintains and expands the luminal patency at the stricture once deployed. 6 months 12 months

Economic impact of migration Assume your hospital does 100 endoscopic retrograde cholangiopancreatography (ERCP) with stent placements per year, with the average patient survival for malignant strictures being six months. GORE VIABIL Short Wire Biliary Endoprosthesis BOSTON SCIENTIFIC WALLFLEX Biliary RX Fully Covered Stent Migration Rate (average) 1 0.2% 4.6% Estimated number of reinterventions to manage migrations (per year) 1 5 Estimated patency at six months 5,6 96.2% 84.3% Estimated number of reinterventions to manage loss of patency (per year) 4 16 Total number of reinterventions expected per year 5 21 Estimated additional cost per year due to $32,205 $151,221 reinterventions (includes ERCP + Stent cost) * Potential economic impact If GORE VIABIL Short Wire Biliary Endoprosthesis was used to treat 100 patients with unresectable malignant biliary strictures, your institution is estimated to annually: ELIMINATE 16 REINTERVENTIONS due to migrations and reduced patency, and SAVE $116,716 versus using BOSTON SCIENTIFIC WALLFLEX Biliary RX Fully Covered Stent. *Average cost of inpatient ERCP is $4649. Source: National Healthcare payer database, 2015 Gore has used reasonable efforts to ensure the completeness and accuracy of the information contained herein as of the date this document was prepared. Gore is not liable for any claims or actions attributable to the use of this, nor for any errors or omissions involved in the use of the information, or the results. Payment policies are variable depending on the payer, geographic location, and provider specific contracts. The models provided here are for illustrative purposes only and are not intended to be indicative of payment from any payer.

Sizing and specifications Endoscopic GORE VIABIL Short Wire Biliary Endoprosthesis Catalogue Number GORE VIABIL Biliary Endoprosthesis Catalogue Number Endoprosthesis Diameter (mm) Length (cm) Working Length of Delivery Catheter (cm) Drainage Holes Located At the Hilar Region Transmural Drainage Holes Length (cm) VSWVN0804 VN0804200 8 x 4 200 No holes VSWVN0806 VN0806200 8 x 6 200 No holes VSWVN0808 VN0808200 8 x 8 200 No holes VSWVN0810 VN0810200 8 x 10 200 No holes VSWVN1004 VN1004200 10 x 4 200 No holes VSWVN1006 VN1006200 10 x 6 200 No holes VSWVN1008 VN1008200 10 x 8 200 No holes VSWVN1010 VN1010200 10 x 10 200 No holes VSWVH0806 VH0806200 8 x 6 200 Holes 2 VSWVH0808 VH0808200 8 x 8 200 Holes 2 VSWVH0810 VH0810200 8 x 10 200 Holes 2 VSWVH1006 VH1006200 10 x 6 200 Holes 2 VSWVH1008 VH1008200 10 x 8 200 Holes 2 VSWVH1010 VH1010200 10 x 10 200 Holes 2 Sizing, availability, and pricing varies by country. Please check with your representative for availability.

ANTI-MIGRATION ASSURANCE PROGRAM DETAILS Gore will provide a replacement device of identical dimensions for use with the patient whose device migrates within one year post implantation. The replacement device is only available if GORE VIABIL Biliary Endoprosthesis is implanted in accordance with the device Instructions for Use (The GORE VIABIL Biliary Endoprosthesis is intended for palliation of malignant strictures in the biliary tree) and the other terms of the program are satisfied. Replacement devices provided under this program are not eligible for the program. Claims under the program are limited to the replacement device. Upon receipt of the appropriate documentation, a replacement device will be provided pursuant to the program accompanied by a no-charge invoice shipped directly to the hospital. The hospital is responsible for reporting the no-charge replacement stent as a discount on the hospital s cost report. All reports of migration will be documented appropriately within the Gore internal product surveillance process and additional information may be requested. Migrations are a known risk of any biliary endoprosthesis. The provision of a replacement device as part of the program does not constitute an admission that there was a device malfunction or defect or that Gore, its employees or agents, or the Gore device caused or contributed to any complications or injuries. Please see the device Instructions for Use for further information on the device contraindications, warnings, precautions, and potential adverse events. The program is subject to modification or termination by W. L. Gore & Associates without prior notification and this program is only applicable for the United States. REFERENCES 1. W. L. Gore & Associates, Inc. Migration Summary for GORE VIABIL Biliary Endoprosthesis and BOSTON SCIENTIFIC WALLFLEX Biliary RX Fully Covered Stent. Flagstaff, AZ: W. L. Gore & Associates, Inc; 2017. [Literature Summary]. AW0010-EN3. 2. W. L. Gore & Associates, Inc. Reduce the risk of reintervention. GORE VIABIL Biliary Endoprosthesis Assurance Brochure. Flagstaff, AZ: W. L. Gore & Associates, Inc; 2017. [Flyer]. AW0165-EN1. 3. Isayama H, Mukai T, Itoi T, et al. Comparison of partially covered nitinol stents with partially covered stainless stents as a historical control in a multicenter study of distal malignant biliary obstruction: the WATCH study. Gastrointestinal Endoscopy 2012;76(1):84-92. 4. Isayama H, Nakai Y, Toyokawa Y, et al. Measurement of radial and axial forces of biliary self-expandable metallic stents. Gastrointestinal Endoscopy 2009;70(1):37-44. 5. Kitano M, Yamashita Y, Tanaka K, et al. Covered self-expandable metal stents with an anti-migration system improve patency duration without increased complications compared with uncovered stents for distal biliary obstruction caused by pancreatic carcinoma: a randomized multicenter trial. Am J Gastroenterol. 2013 Nov;108(11):1713-22. 6. Krokidis M, Fanelli F, Orgera G, Bezzi M, Passariello R, Hatzidakis A. Percutaneous treatment of malignant jaundice due to extrahepatic cholangiocarcinoma: covered Viabil stent versus uncovered Wallstents. Cardiovascular & Interventional Radiology 2010;33(1):97-106. W. L. Gore & Associates, Inc. Flagstaff, AZ 86004 +65.67332882 (Asia Pacific) 800.437.8181 (United States) 00800.6334.4673 (Europe) 928.779.2771 (United States) goremedical.com Products listed may not be available in all markets. WALLFLEX is a trademark of Boston Scientific Corporation. CONMED and designs are trademarks of CONMED Corporation. MCM2017159 GORE, VIABIL, and designs are trademarks of W. L. Gore & Associates. 2017 W. L. Gore & Associates, Inc. AW0305-EN3 AUGUST 2017