ProAir Clear 2 Pack FOR PROFESSIONAL USE ONLY

Similar documents
Product Data Sheet July 2014

EHS Hi-Gloss 383 P383-Line V1900V. EHS Hi-Gloss 383 P383-Line

Technical Data Sheet February 2018

Transparent Sealer P EHS System

Acrylic thinner, standard, fast, slow and extra slow

Transparent Sealer P EHS System

Acrylic thinner, standard, fast, slow and extra slow

Canada VOC Limits for Automotive Refinishing Regulations Effective June 18, 2010

Allylic alcohols improve acrylic polyols

KEY RESIN #510LV EPOXY BINDER

Step-By-Step Product Selection Guide

Technical Datasheet Issue: March 2018

POLYTONE UA 810. Aldehyde Resin

PRO-V IDS Kit. Bisco. Instructions for Use. Provisional Restorative System

MATERIAL SAFETY DATA SHEET

EMERGENCY PHONE MATERIAL SAFETY DATA SHEET MP5405/5430/5445 PART A (RESIN)

MATERIAL SAFETY DATA SHEET

ÆLITE Composites. Bisco. Instructions for Use. Light- Cured. U.S. Patent: 6,709,271

Technical Datasheet Issue: August 2018

MATERIAL SAFETY DATA SHEET BISSELL Homecare Inc. PRINT DATE: May 24, 2012

Araldite Advanced Materials. Two component toughened methacrylate adhesive system. Structural Adhesives TECHNICAL DATASHEET

Sheets. Premier Red Aluminum Oxide Dri-Lube Resin Paper Open. Carbo Gold Aluminum Oxide Dri-Lube Paper Open. Aluminum Oxide Waterproof Paper

PRIMAL HG-98 Binder. Pure Acrylic Polymer for Gloss and Semi-Gloss Paints

Ident-No: HARDENER HV 998

The right impact on taste and texture CONDITIONING COATING BROCHURE

Coating powders are mixtures of pigments, resins, curing. As the coating powder is sprayed through the nozzle of the

Pulpdent Corporation Revision Date: May 1, 2017 Safety Data Sheet

Material Safety Data Sheets Alumilite Corporation 315 E. North St. Kalamazoo, MI Emergency Telephone: Chemtrec

DuPont Nafion PFSA Membranes NRE-211 and NRE-212 Perfluorosulfonic acid polymer. Membranes. Product Information. Description. Coversheet.

Pulpdent Corporation Revision Date: May 1, 2017

K-KAT Non-Tin, Mercury-Free Urethane Catalysts K-KAT URETHANE CATALYSTS. K-KAT Catalyst Selection Chart - Coatings. Tin alternative (Coatings)

Methacrylate adhesive with good thermal stability. Good adhesion even without particular pretreatment. Mix ratio Parts by weight Parts by volume

SAFETY DATA SHEET According to regulation (EU) No. 453/2010 DATE

AVANTI POLAR LIPIDS SAFETY DATA SHEET Page 1 of 6

MATERIAL SAFETY DATA SHEET

P-Tert-Butylbenzoic Acid

MSDS Material Safety Data Sheet

TECHNICAL DATA SHEET GROWCLEAR PLUS

APPROVAL DATE: 10/18/2006 Page: 1 of 7

Safety Data Sheet HARD-ROK ANCHORING CEMENT Created On: 03/10/2015 Revision Date: 03/01/16 Version: 3.0

Date Printed: 03/31/2009 Date Updated: 02/06/2006 Version 1.3 ELLAGIC ACID FROM TREE BARK. Substance Name CAS # SARA 313 ELLAGIC ACID No

BIS-SILANE. Bisco Instructions for Use. 2-Part Porcelain Primer

Copper sulfide (Cu2S) (cas ) MSDS

#1 Trincity Drive Trincity Industrial Estate Trincity Trinidad and Tobago 2. COMPOSITION/INFORMATION ON INGREDIENTS CAS CHEMICAL NAME % WEIGHT

Emergency telephone Gorilla Glue Europe A/S. Tel: The Gorilla Glue Company. Tel: 001 (513)

Chemical Name: Interior Acrylic Latex. Manufacturer: Sherwin Williams. Container size: 1 gallon. Location: VLA

Successful Operation of Electrophoretic Lacquers

Pulpdent Corporation Revision Date: May 6, 2014 Safety Data Sheet

RESINOMER Dual- Bisco. Instructions for Use. Cured Amalgam Bonding/Luting System

MATERIAL SAFETY DATA SHEET

Material Safety Data Sheet

RHOPLEX AC-464 Emulsion Polymer

SP 131 NONIONIC SPREADER/PENETRANT

RHOPLEX SF-3122 Binder for Solvent-Free Exterior Flat and Satin Paints

Material Safety Data Sheet

Fibrlok II 2529 Universal Optical Fiber Splice

Application Data MPDIOL Glycol MPDIOL Glycol in Polyester Resins for Low-VOC Waterborne Can or Coil Coatings

Material Safety Data Sheet

NPK Fertilizer SAFETY DATA SHEET (SDS) OSHA Haz Com Standard 29 CFR Prepared to GHS Rev03.

Clariant Mining Fertilizer Additives

SECTION 1: Identification of the substance/mixture and of the company/undertaking

SAFETY DATA SHEET. Section 1. IDENTIFICATION

Material Safety Data Sheet This MSDS is prepared in accordance with OSHA 29 CFR

SAFETY DATA SHEET 1. IDENTIFICATION OF THE SUBSTANCE / MIXTURE AND OF THE COMPANY / UNDERTAKING. An effective degreaser for use on all surfaces

PRODUCT AND COMPANY IDENTIFICATION

UV + PVD: PERFORMANCE AND DESIGN SOLUTIONS FOR THE AUTOMOTIVE INDUSTRY. Eileen M. Weber, Red Spot Paint and Varnish, Co., Inc.

ZEST DANVILLE MATERIALS PERIOSCOPY

KEY PRODUCT FOR HL SAFETY DATA SHEET

Engineering Materials

SIGMA-ALDRICH. Material Safety Data Sheet Version 4.0 Revision Date 02/28/2010 Print Date 08/24/2011

MATERIAL SAFETY DATA SHEET Issue Date: June 27, 2018

Clariant Mining Emulsifiers for Explosives

Material Safety Data Sheet

Essential oils,sandalwood (cas ) MSDS

APPROVAL DATE: 10/18/2006 Page: 1 of 7

Material Safety Data Sheet

Pulpdent Corporation Revision Date: May 1, 2017

SAFETY DATA SHEET ULTIMEG 2220

3D Printing Dentures. Dental Application Print Guide

: Sikalastic Metal Primer MY Part B

Pulpdent Corporation Revision Date: May 7, 2014

: Corian Joint Adhesive Kit - Component A

Product Safety Assessment Toluenediamine Propoxylated/Ethoxylated Polyols

INSTRUCTIONS FOR USE AND CARE

LUPIN LIMITED SAFETY DATA SHEET

Date Printed: 1. CHEMICAL PRODUCT AND COMPANY IDENTIFICATION

AROLON 6436 Product Code: Acrylic Polyol

Material Safety Data Sheet

Transcription:

Description The Lesonal ProAir Clear Pack Fast or Slow Clear is an acrylic urethane clearcoat for use over Lesonal Basecoat SB or Lesonal WB and intended for applications in cross flow and air-dry conditions. ProAir Clear Pack Fast or Slow Clear offers a built in flex package and excellent resistance to surface contamination with excellent gloss, making it an ideal choice for air dry environments. Safety Considerations Use suitable personal protection. AkzoNobel recommends the use of a fresh air supply respirator. Refer to the product Safety Data Sheet (SDS) for more complete safety information. Mixing Lesonal ProAir Clear Pack Fast or Lesonal ProAir Clear Pack Slow Lesonal ProAir Clear Hardener HVLP or Compliant Spray-Gun Set-Up: Application Air Pressure:.3-.5 mm Application Apply medium wet coats allowing for flash in between. Consult spray gun manufacturers specifications. HVLP 0 psi at the air cap maximum. Flash Between Coats at 70 F ( C) 5-0 minutes Air Drying at 70 F ( C) Dry to Handle 3 hours ProAir Clear Pack Fast 8 hours ProAir Clear Pack Slow Flash Before Force Drying at 70 F ( C) 5-0 minutes Force Drying at 0 F (49 C) Dry to Handle 0 minutes ProAir Clear Pack Fast 30 minutes ProAir Clear Pack Slow *Do not exceed 0 F as you may experience coating defects. Read complete TDS for detailed product information. @ 06 AkzoNobel N. V. All Rights Reserved Page

Description The Lesonal ProAir Clear Pack Fast or Slow Clear is an acrylic urethane clearcoat for use over Lesonal Basecoat SB or Lesonal WB and intended for applications in cross flow and air-dry conditions. ProAir Clear Pack Fast or Slow Clear offers a built in flex package and excellent resistance to surface contamination with excellent gloss, making it an ideal choice for air dry environments. Suitable Substrates Lesonal WB Basecoat- after a flash off time of 5-0 minutes at 70 F ( C) Lesonal SB Basecoat after a flash off time of 5-0 minutes at 70 F ( C) Existing finishes that have been sanded and degreased in the case of spot repairs and blending. Products and Additives Product Hardeners Additives ProAir Clear Pack Fast ProAir Clear Pack Slow ProAir Clear Hardener General purpose hardener for all repair sizes EZ Matte Lesonal Accelerator Lesonal Flex Additive (For soft parts only) Item #539485 Item #539486 Item #539540 Item #5058 Item #39767 Item #39607 Basic Raw Materials Substrate Preparation ProAir Clear Pack Fast and Slow Acrylic polyol resins ProAir Clear Hardener - Polyisocyanate resins Additives - Refer to the individual TDS for information. Surface Cleaning Prior to Paint Application Clean with Sikkens M600, Autoclean or Anti-Static surface cleaners. Mixing Standard Ratio Parts by volume ProAir Clear Pack Fast or Slow Parts by volume ProAir Clear Hardener ProAir Clear Pack Fast and Slow s can be blended to accommodate spraying conditions @ 06 AkzoNobel N. V. All Rights Reserved Page

Mixing Accelerated Ratio ounce to RTS quart Parts by volume ProAir Clear Pack Fast or Slow Parts by volume ProAir Clear Hardener Parts by volume Lesonal Accelerator Mixing Soft Parts Lesonal ProAir Clear Pac does not require flex additive when being applied over plastic substrates. However, Lesonal Flex Additive is needed when soft foam parts are being painted. 00 0-5% Parts by volume ProAir Pack Fast or Slow Parts by volume Lesonal Flex Additive Stir the paint with Flex Additive together THEN Parts by volume ProAir Clear Pack Fast or Slow with Flex Additive Parts by volume ProAir Clear Hardener Viscosity When Mixed DIN #4 4-7 seconds Measured with a DIN #4 viscosity cup at 70 F ( C). Pot-Life When Mixed Product Mix ProAir Clear Pack Fast ProAir Clear Pack Fast Accelerated ProAir Clear Pack Slow ProAir Clear Pack Slow Accelerated 70 F ( C) hours.5 hours 4 hours hours @ 06 AkzoNobel N. V. All Rights Reserved Page 3

Spray Gun Set-Up Application Spray Gun Fluid Tip Application Pressure HVLP Gravity Fed Compliant Gravity Fed.3-.5 mm 0.055-0.059.3-.5 mm 0.055-0.059 8-0 psi at air cap 0.65-0.8 bar at air cap Consult equipment manufacturer s recommendations. Apply single flowing coats. If heavy sanding and polishing is required, a third coat may be applied after the stated flash off time. Allow a flash off time between coats of 5-0 minutes. Flash time will be dependent on ambient temperature, applied paint wetness/thickness and available air-flow. Film Thickness Using Suitable Application Drying / Curing Time Coat will achieve a thickness of.-.5 mils (30-38 μm). Below is a table showing the drying times of Pro Air Clear Pack Fast or Slow with Pro Air Clear Hardener. The air-dry times stated may increase with insufficient airflow. Drytimes were measured under the following conditions: Testing was done at 70 F ( C). Temperatures are reported as metal temerature. Accelerated drytimes were measured when ounce of Lesonal Accelerator is added per ready to spray quart or clearcoat. Standard Mix Dust Free Accelerated Mix Dust Free Standard Mix Dry Accelerated Mix Dry Slow (75% / 5%) (50% / 50%) (5% / 75%) Fast 0 minutes 5 minutes 5 minutes 5 minutes 0 minutes 0 minutes 0 minutes 5 minutes 5 minutes 5 minutes 8 hours 7-/ hours 4 hours 3-/ hours 3 hours 4 hours 3 hours -/ hours hours hours @ 06 AkzoNobel N. V. All Rights Reserved Page 4

Drytimes were also measured at a low bake temperature of 0 F (49 C). Note: Do not exceed 0 F as you may experience coating defects. Do not bake an accelerated system. Standard Mix Dry to Handle Slow (75% / 5%) (50% / 50%) (5% / 75%) Fast 30 minutes 30 minutes 5 minutes 0 minutes 0 minutes Drying / Curing with short wave light IR equipment is not recommended. Recoating ProAir Clear Pack Fast or Slow can be re-coated with itself at any stage. Sanding will become necessary after 4 hours. Polishing, Decals and Lettering Polishing Dust and minor damage can be polished out after the stated air-dry times have been reached. Carefully sand out dust particles with #0 micron (#500) grit paper wet, and then polish the area mechanically. Note: When heavy color sanding and polishing are required, it may be necessary to apply one extra coat of Pro Air Clear Pack Fast or Slow Clear. When completed, a minimum of.4 mils of clearcoat is required for adequate durability. Decals Decals can be applied after 48 hours at 70 F ( C) Lettering Painted striping or lettering must be applied within 48 hours for good adhesion. After 48 hours, scuff with a gray scuffing pad. Cleaning of Equipment Clean equipment following local and federal regulations. In compliant localities, use Sikkens LV Cleaning Solvent or high quality solvent borne gun cleaner. For national rule regions, use Sikkens Cleaning Solvent or high quality lacquer thinner. @ 06 AkzoNobel N. V. All Rights Reserved Page 5

Theoretical Coverage Theoretical coverage is dependent of many factors. These may include; the shape of the object, surface smoothness, application technique and other application variables among others. Coverage is given at mil of applied ready to spray paint with 00% transfer efficiency. 586 Sq ft / gallon 4.5 m / liter VOC / Regulatory Information Ready to Spray VOC at : mixture Pro Air Clear Pack Fast or Slow yields a VOC content of: 3.66 lb/gal 440 g/liter Product Storage Notice: Do not handle until the Safety Data Sheets have been read and understood. Regulations require that all employees be trained on Material Safety Data Sheets for all chemicals with which they come in contact. The manufacturer recommends the use of an air-supplied respirator when exposed to vapors or spray mist. Stock unopened or used products in approved closed containers with proper labeling. Store in moderate temperatures between 40 F - 95 F (5 C 35 C). Avoid too much temperature fluctuation. Optimum storage temperature is approximately 70 F ( C). ProAir Clear Pack Fast ProAir Clear Pack Slow ProAir Clear Hardener years years 6 months IMPORTANT NOTE The information in this data sheet is not intended to be exhaustive and is based on the present state of our knowledge and on current laws: any person using the product for any purpose other than that specifically recommended in the technical data sheet without first obtaining written confirmation from us as to the suitability of the product for the intended purpose does so at his own risk. It is always the responsibility of the user to take all necessary steps to fulfill the demands set out in the local rules and legislation. Always read the Material Data Sheet and the for this product if available. All advice we give or any statement made about the product by us (whether in this data sheet or otherwise) is correct to the best of our knowledge but we have no control over the quality or the condition of the substrate or the many factors affecting the use and application of the product. Therefore, unless we specifically agree in writing otherwise, we do not accept any liability whatsoever for the performance of the product or for any loss or damage arising out of the use of the product. All products supplied and technical advices given are subject to our standard terms and conditions of sale. You should request a copy of this document and review it carefully. The information contained in this data sheet is subject to modification from time to time in the light of experience and our policy of continuous development. It is the user's responsibility to verify that this data sheet is current prior to using the product. Coatings brand names mentioned in this data sheet are trademarks of or are licensed to AkzoNobel. AkzoNobel 845 Maxwell Street Troy, MI 48084 USA -800-68-00 @ 06 AkzoNobel N. V. All Rights Reserved Page 6