Improving Reading Time of Digital Breast Tomosynthesis with Concurrent Computer Aided Detection

Similar documents
Since its introduction in 2000, digital mammography has become

FDA Executive Summary

Breast tomosynthesis reduces radiologist performance variability compared to digital mammography

Women s Imaging Original Research

EARLY DETECTION: MAMMOGRAPHY AND SONOGRAPHY

Mammography limitations. Clinical performance of digital breast tomosynthesis compared to digital mammography: blinded multi-reader study

WHAT TO EXPECT. Genius 3D Mammography Exam. The most exciting advancement in mammography in over 30 years

EARLY DETECTION: MAMMOGRAPHY AND SONOGRAPHY

Session 4: Test instruments to assess interpretive performance challenges and opportunities Overview of Test Set Design and Use

S. Murgo, MD. Chr St-Joseph, Mons Erasme Hospital, Brussels

Tomosynthesis and breast imaging update. Dr Michael J Michell Consultant Radiologist King's College Hospital NHS Foundation Trust

Digital Breast Tomosynthesis

Amammography report is a key component of the breast

Breast asymmetries in mammography: Management

arxiv: v2 [cs.cv] 8 Mar 2018

DESCRIPTION: Percentage of final reports for screening mammograms that are classified as probably benign

Can Digital Breast Tomosynthesis(DBT) Perform Better than Standard Digital Mammography Workup in a Breast Cancer Assessment Clinic?

Update of Digital Breast Tomosynthesis. Susan Orel Roth, MD

DESCRIPTION: Percentage of final reports for screening mammograms that are classified as probably benign

Women s Imaging Original Research

A comparison of the accuracy of film-screen mammography, full-field digital mammography, and digital breast tomosynthesis

Detection and Classification of Calcifications on Digital Breast Tomosynthesis and 2D Digital Mammography: A Comparison

Breast Tomosynthesis

Breast Tomosynthesis

Mammography. What is Mammography?

Financial Disclosures

Name of Policy: Computer-aided Detection (CAD) Mammography

Improvement in ROC curves of readers with next generation of mammography CAD

Medical Policy An independent licensee of the Blue Cross Blue Shield Association

Breast Tomosynthesis An additional screening tool in the fight against breast cancer

WHAT TO EXPECT. Breast Tomosynthesis An additional screening tool in the fight against breast cancer HOLOGIC. The Women's Health Company

BI-RADS classification in breast tomosynthesis. Our experience in breast cancer cases categorized as BI-RADS 0 in digital mammography

Electrical impedance scanning of the breast is considered investigational and is not covered.

WHAT TO EXPECT. Genius 3D MAMMOGRAPHY Exam. The most exciting advancement in mammography in over 30 years

Retrospective study comparison of Arcadia Lab s Galileo and Parascript AccuDetect Galileo CAD systems in screening environment.

Retrospective Study Comparison of Arcadia Lab s Galileo and Parascript AccuDetect Galileo CAD systems in screening environment.

Breast Imaging! Ravi Adhikary, MD!

Jing Zhang, PhD, Lars J. Grimm, MD, MHS, Joseph Y. Lo, PhD, Karen S. Johnson, MD,

Bianca den Dekker, MD - PhD student. Prof dr R.M. Pijnappel Prof dr H.M. Verkooijen Dr M. Broeders

TOMOSYNTHESIS: WORTH ALL THE HYPE?

9/3/2015. New Mammographic Modality Training. Mammographer. Qualified Radiologic Technologist. Tomosynthesis Training

The GE Breast Health Advantage

Mammography. What is Mammography? What are some common uses of the procedure?

MEDICAL POLICY SUBJECT: MAMMOGRAPHY: COMPUTER- AIDED DETECTION (CAD) POLICY NUMBER: CATEGORY: Technology Assessment

BCSC Glossary of Terms (Last updated 09/16/2009) DEFINITIONS

BI-RADS 3 category, a pain in the neck for the radiologist which technique detects more cases?

The Radiology Aspects

The value of the craniocaudal mammographic view in breast cancer detection: A preliminary study

Corporate Medical Policy

Outline. Digital Breast Tomosynthesis: Update and Pearls for Implementation. Tomosynthesis Dataset: 2D/3D (Hologic Combo Acquisition)

8/31/2016 HIDING IN PLAIN SITE, ARCHITECTURAL DISTORTIONS AND BREAST ASYMMETRIES ARCHITECTURAL DISTORTIONS ARCHITECTURAL DISTORTIONS

Multicenter Trial, Phase I Assessment of 2-D FFDM Versus Combo of 2-D and 3-D Tomosynthesis in Breast Cancer Screening

Mammographic imaging of nonpalpable breast lesions. Malai Muttarak, MD Department of Radiology Chiang Mai University Chiang Mai, Thailand

Overview of the 2005 IOM Report Improving Breast Imaging Quality Standards

Challenges to Delivery of High Quality Mammography

In multiple published papers digital breast

Session 2: The Role of Specialist Radiology Technologists

Management of Palpable Abnormalities in the Breast Katerina Dodelzon, MD July 31, 2018, 7:00pm ET

Is Probably Benign Really Just Benign? Peter R Eby, MD, FSBI Virginia Mason Medical Center Seattle, WA

Disclosures. Breast Cancer. Breast Imaging Modalities. Breast Cancer Screening. Breast Cancer 6/4/2014

Radiation Dosimetry in Digital Breast Tomosynthesis. March, 2015 William J. O Connel, Dr. Ph, Senior Medical Physicist

In multiple published papers digital breast

Objectives. Explanation of Radiation Dose Terminology 10/9/2018. What are these lines?

CHAPTER 2 MAMMOGRAMS AND COMPUTER AIDED DETECTION

Digital breast tomosynthesis (DBT) occult breast cancers: clinical, radiological and histopathological features.

Fundamentals of Breast Tomosynthesis

Stanford Breast in the West: Multi-Modality Breast Imaging Symposium for Radiologists

WOMEN S HEALTH SOLUTIONS. The power and promise of breast tomosynthesis is here. Selenia Dimensions system with Acquisition Workstation 8000

Contrast-Enhanced Digital Mammography

Diagnostic Dilemmas of Breast Imaging

Breast Tomosynthesis

Features of Prospectively Overlooked Computer-Aided Detection Marks on Prior Screening Digital Mammograms in Women With Breast Cancer

HISTORY OF MQSA AND ACR

The power and promise of breast tomosynthesis is here. Selenia Dimensions system with Acquisition Workstation 5000

Digital Breast Tomosynthesis in the Diagnostic Environment: A Subjective Side-by-Side Review

New Palpable Breast Lump With Recent Negative Mammogram: Is Repeat Mammography Necessary?

Does the synthesised digital mammography (3D-DM) change the ACR density pattern?

Standard Breast Imaging Modalities. Lilian Wang, M.D. Breast Imaging Section Department of Radiology Northwestern Medicine

Implementation of Breast Tomosynthesis in a Routine Screening Practice: An Observational Study

BI-RADS Categorization As a Predictor of Malignancy 1

What s New in Breast Imaging. Jennifer A. Harvey, M.D., FACR Professor of Radiology University of Virginia

CONTRACTING ORGANIZATION: Duke University Durham, North Carolina 27710

Updates in Mammography. Dr. Yang Faridah A. Aziz Department of Biomedical Imaging University Malaya Medical Centre

Breast Tomosynthesis. What is breast tomosynthesis?

Digital Breast Tomosynthesis

Purpose. [Purpose] [Introduction] Architectural distortion on mammography

Corporate Medical Policy

Pathologic outcomes of coarse heterogeneous calcifications detected on mammography

Additional US or DBT after digital mammography: which one is the best combination?

2017 Reimbursement Information for Mammography, CAD and Digital Breast Tomosynthesis 1

Here are examples of bilateral analog mammograms from the same patient including CC and MLO projections.

TOMOSYNTHESIS. Daniela Bernardi. U.O. Senologia Clinica e Screening mammografico APSS Trento, Italy

Spiculated breast masses on MRI: Which category should we choose, 4 or 5?

Screening with Abbreviated Breast MRI (AB-MR)

Medical Policy An independent licensee of the Blue Cross Blue Shield Association

BREAST DENSITY WHAT IS IT? WHY IS IT IMPORTANT? & What IOWA SF250 Means to Patients and Providers

Digital Breast Tomosynthesis from a first idea to clinical routine

Min Jung Kim Department of Medicine The Graduate School, Yonsei University

Mammography is a most effective imaging modality in early breast cancer detection. The radiographs are searched for signs of abnormality by expert

2015 Reimbursement Information for Mammography, CAD and Digital Breast Tomosynthesis 1

Transcription:

White Paper Improving Reading Time of Digital Breast Tomosynthesis with Concurrent Computer Aided Detection WHITE PAPER

2

3 Abstract PowerLook Tomo Detection, a concurrent computer-aided detection (CAD) system for digital breast tomosynthesis (DBT) developed by icad, Inc., Nashua, NH, was tested to determine if the software can shorten the reading time of DBT without affecting radiologist interpretation or performance. The results of this study showed a 29.2% average reduction in reading time (up to 36.5% reduction) with the use of PowerLook Tomo Detection while maintaining radiologists performance and accuracy. Introduction DBT is one of the most accurate screening methods available for detecting breast cancer. However, this method produces significantly more images than full-field digital mammography (FFDM), therefore DBT requires considerably more time for radiologists to review. A major advancement in DBT would shorten radiologist reading time, while maintaining clinical high clinical performance. PowerLook Tomo Detection uses DBT images to produce a CAD-enhanced 2D synthetic image. The system detects soft tissue densities (masses, architectural distortions and asymmetries) using the 3D tomosynthesis planes. The detected regions are blended into a corresponding 2D synthetic image to produce the resulting CAD-enhanced synthetic image (Figure 1). The enhanced image assists radiologists in identifying soft tissue densities and provides navigation capabilities from the suspected lesion to the corresponding 3D DBT planes; the lesions are then confirmed or dismissed by the radiologist. This study [Benedikt et al. 2017] was conducted to evaluate the radiologist s reading time, accuracy and performance with and without PowerLook Tomo Detection. The standalone performance assessed system performance without a radiologist. Standard 2D Synthetic Image CAD-Enhanced 2D Synthetic Image DBT Planes Figure 1. Use of Concurrent DBT CAD System

4 Materials and Methods Study Design A retrospective multi-reader, multi-case crossover study was conducted in which all readers reviewed images from 240 women in two sessions (Figure 2). Each session was separated by a 4- week washout period. All cases were read by each reader twice, once with PowerLook Tomo Detection and once without. Cases read with Tomo Detection comprised the experimental group while cases read without served as controls. The case reading order was individually randomized for each radiologist. Radiologists independently reviewed exams from randomly selected cases. Figure 2: Study Design Cases All 240 cases were from women undergoing bilateral screening or diagnostic tomosynthesis exams. Women were excluded from this study if they had a personal history of breast cancer or images indicating prior breast surgery. Cases were selected based on case type (negative, recalled, benign, or cancer), mammographic appearance, size and histopathology of lesions, breast density, and ACR BI-RADS assessment categories [Sickles et al. 2013]. The lesions present in all cases were verified by a radiologist with expertise in breast imaging. Readers Twenty board-certified radiologists with a range of experience served as readers for this study. All readers were qualified to interpret mammograms under the Mammography Quality Standards Act (MQSA), and had interpreted more than 500 DBT exams in the last two years. Eleven readers devoted less than 75% of their professional time to breast imaging for the last 3 years, while nine readers devoted more than 75% of their professional time to breast imaging. All readers received training on the study reading protocol with 30 additional DBT cases used for practice.

5 Image Interpretation Each radiologist read each case, assessed breast density and determined if there were questionable or suspicious lesions that would require recall, short-interval follow-up, or tissue diagnosis. If no questionable lesions were found, the reader recorded the level of suspicion (LOS) score and assigned a BI-RADS assessment category. For each suspicious lesion, the reader recorded the LOS score, BI-RADS category, mammographic appearance including soft tissue density and/or calcifications and marked the location of each lesion using the workstation. Reading Time Reading time was measured (in seconds) from the time the reader started examining the images to the time the reader stopped viewing the images. Reading time did not include the time needed for documentation. The reading time timer was hidden from view of all readers. Standalone Performance Standalone performance assessed the ability of Tomo Detection to detect malignant lesions without a radiologist. Specifically, this study determined enhanced 2D synthetic image sensitivity for malignant soft tissue densities and mixed lesions at the case-level and lesion-level. Malignant lesions were determined to be correctly detected when the centroid of a CAD detection was within the 3D truth volume established by the expert breast imaging (truthing) radiologist. True positives for enhanced 2D synthetic image sensitivity were lesions correctly detected by PowerLook Tomo Detection and blended into the 2D synthetic image and lesions not detected by Tomo Detection but determined to be visible on the standard synthetic image by the expert radiologist. Statistical Methods Radiologist performance was assessed by measuring the area under the curve for the detection of malignant lesions. The area under the curve and reading times were evaluated using a multi-reader multi-case mixed effects analysis of variance method [Obuchowski and Rockette, 1995] with degrees of freedom adjusted for estimation [Hillis, 2007]. A statistical test was used to determine if percent differences in reading time were normally distributed. Because these differences were not normally distributed, a normalizing transformation for percent difference was used and the resulting percent difference was back-transformed to the original scale [Balleyguier et al. 2017]. Sensitivity, specificity and recall rate in non-cancers were also assessed. Results Area Under the Curve The average area under the curve across readers without Tomo Detection was 0.841 and the average across readers with Tomo Detection was 0.850. The readers plots with and without Tomo Detection tended to overlap and cross each other. This study demonstrated non-inferior area under the curve, which indicates similar radiologist performance with and without Tomo Detection. Reading time improved with Tomo Detection as indicated by 19 out of 20 readers who decreased their reading time with Tomo Detection (Figure 3). The average reading time for the same case was 19 seconds (p<0.01) faster with Tomo Detection compared to the same case without. These data demonstrate a 12.6 to 26.6 second reduction in reading time with Tomo Detection. For percent difference, the average reduction in reading time was 29.2% (p < 0.01) with Tomo Detection. This corresponds to average reading times of 46.3 seconds with Tomo Detection compared to 65.3 seconds without. Radiologist reading time with Tomo Detection was shorter than radiologist reading time without CAD.

6 Figure 3: Average Reading Times for Each Reader With and Without Tomo Detection. Sensitivity, Specificity and Recall Rate Per-subject sensitivity increased with Tomo Detection overall (from 84.7% without to 87.1% with Tomo Detection) and in cancer cases with at least one soft tissue density or mixed lesion (from 83.7% without to 87.1% with Tomo Detection). For cancer cases with only calcifications, persubject sensitivity slightly decreased (from 88.1% without to 87.3% with Tomo Detection). The average lesion-level sensitivity with Tomo Detection was 84.5%, which was higher than without Tomo detection (82.3%). The average specificity with Tomo Detection was 50.9%, which was slightly lower than without (52.7%). Average recall rate for non-cancers increased a small amount with Tomo Detection (49.2%) compared to without (47.4%). Standalone Study Results of the standalone study indicate the proportion of biopsy-proven malignant lesions detected by PowerLook Tomo Detection as soft tissue densities were 91.7% (44 out of 48) at the case-level and 92.3% (48 out of 52) at the lesion-level (Table 1). Tomo detection sensitivity for malignant soft tissue densities and calcifications was lower, 72.1% (44 out of 61) at the case-level and 70.6% (48 out of 68) at the lesion-level, because the system was not designed to detect calcifications. In contrast, the sensitivity of the standard 2D system was much lower for soft tissue densities without (case-level 52.1%, 25 out of 48; lesion-level 51.9%, 27 out of 52) and with calcifications (case-level 62.3%, 38 out of 61; lesion-level 63.2%, 43 out of 68) at both the case- and lesion-levels. The proportion of biopsy-proven malignant lesions visible with the standard 2D synthetic images for soft tissue densities was 52.1% (25 out of 48) at the case-level and 51.9% (27 out of 52) at the lesion-level. In contrast, the proportion of biopsy-proven malignant lesions visible in the enhanced

7 2D synthetic image for soft tissue densities was considerably higher: 91.7% (44 out of 48) at the case-level and 90.4% (47 out of 52) at the lesion-level Although PowerLook Tomo Detection was designed for soft tissue densities only, performance with calcifications was included and enhanced 2D synthetic image sensitivity for soft tissue densities and calcifications was 91.8% (56 out of 61) at the case-level and 91.2% (62 out of 68) at the lesionlevel. Performance Measure Tomo Detection Sensitivity for Soft Tissue Densities Tomo Detection Sensitivity for Soft Tissue Densities and Calcifications Standard 2D Synthetic Sensitivity for Soft Tissue Densities Standard 2D Synthetic Sensitivity for Soft Tissue Densities and Calcifications Enhanced 2D Synthetic Image Sensitivity for Soft Tissue Densities Enhanced 2D Synthetic Image Sensitivity for Soft Tissue Densities and Calcifications * CI represents confidence intervals. Calcifications are not detected by PowerLook Tomo Detection. Case-Level with 95% CI* 0.917 (44/48) (0.804, 0.967) 0.721 (44/61) (0.598, 0.818) 0.521 (25/48) (0.383, 0.655) 0.623 (38/61) (0.497, 0.734) 0.917 (44/48) (0.804, 0.967) 0.918 (56/61) (0.822, 0.964) Lesion-Level with 95% CI* 0.923 (48/52) (0.849, 0.997) 0.706 (48/68) (0.588, 0.824) 0.519 (27/52) (0.372, 0.667) 0.632 (43/68) (0.506, 0.758) 0.904 (47/52) (0.824, 0.984) 0.912 (62/68) (0.844, 0.979) Table 1: PowerLook Tomo Detection Standalone Performance Conclusion PowerLook Tomo Detection creates a CAD-enhanced 2D synthetic image in which a radiologist can recognize the malignant soft tissue densities with 91.7% sensitivity at the case level with only the Tomo Detection-enhanced image (standalone data). With a radiologist also interpreting the DBT planes, the system enables the review of DBT images 29.2% faster, with similar performance and accuracy. References 1. Obuchowski NA, Rockette HE. Hypothesis testing of diagnostic accuracy for multiple readers and multiple tests an anova approach with dependent observations. Communications in Statistics - Simulation and Computation 1995; 24:285-308 2. Hillis SL. A comparison of denominator degrees of freedom methods for multiple observer ROC analysis. Statistics in Medicine 2007; 26:596-619 3. Sickles E, D'Orsi C, Bassett L, et al. ACR BI-RADS Atlas Breast Imaging Reporting and Data System. Reston, VA: American College of Radiology 2013 Acknowledgements We thank scientific writer Andrea Gwosdow, Ph.D. for writing and assistance with the white paper.

8 DMM232 Rev. A 2017, icad Inc. All rights reserved. icad, the icad logo are trademarks of icad, Inc. Reproduction of any of the material contained herein in any format or media without the express written permission of icad, Inc. is prohibited