Applications in brachytherapy

Similar documents
Specific Aspects of Radiochromic Film Dosimetry AAPM Task Group 235 An Update to Task Group 55 (1998)

ROPES eye plaque dosimetry: commissioning and verification of an ophthalmic brachytherapy treatment planning system

Radiochromic film dosimetry in water phantoms

CALCULATION OF BACKSCATTER FACTORS FOR LOW ENERGY X-RAYS USING THE TOPAS MONTE CARLO CODE

University of Wollongong. Research Online

Manik Aima, Larry A. DeWerd, Wesley S. Culberson

Y FILMS DOSIMETR Nederland België / Belgique

Energy response of EBT3 radiochromic films: implications for dosimetry in kilovoltage range

Optimisation of eye plaque dosimetry using Monte Carlo method. J. Green, D. Cutajar, S. Guatelli, & Rosenfeld, A.B.

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Practical Reference Dosimetry Course April 2015 PRDC Program, at a glance. Version 1.0. Day 1 Day 2 Day 3 Day 4

Absorbed Dose Response in Water of Kilovoltage X-rays Beams of Radiochromic Film and Thermoluminescent for Brachytherapy Dosimetry

Topics covered 7/21/2014. Radiation Dosimetry for Proton Therapy

Dosimetric characterization of surface applicators for use with the Xoft ebx system

Dose distribution and dosimetry parameters calculation of MED3633 palladium-103 source in water phantom using MCNP

GAFCHROMIC DOSIMETRY MEDIA TYPE MD-V3

Current Status of Electronic Brachytherapy Dosimetry

A comparison of dose distributions measured with two types of radiochromic film dosimeter MD55 and EBT for proton beam of energy 175 MeV

A preliminary clinic dosimetry study for synchrotron radiation therapy at SSRF

MAX-HD SRS PHANTOM THE COMPREHENSIVE END-TO-END SRS PHANTOM SCAN PLAN LOCALIZE TREAT. distributed by:

M. J. Maryanski, Three Dimensional BANG Polymer Gel Dosimeters AAPM'99, CE Course

Monte Carlo simulation of 192 Ir radioactive source in a phantom designed for brachytherapy dosimetry and source position evaluation.

Calibration of 90 Sr+ 90 Y sources used for betatherapy, using a postal kit of thermoluminescent dosimeters

AAPM Administrative Policy: Joint AAPM/IROC Houston Registry of Brachytherapy Sources Complying with AAPM Dosimetric Prerequisites

Advanced film dosimetry for a UK brachytherapy audit

Review of TG-186 recommendations

Production and dosimetry of simultaneous therapeutic photons and electrons beam by linear accelerator: a monte carlo study

In vivo dosimetry and shielding disk alignment verification by EBT3 GAFCHROMIC film in breast IOERT treatment

Brachytherapy Planning and Quality Assurance w Classical implant systems and modern computerized dosimetry w Most common clinical applications w

Slide 1. Slide 2. Slide 3. Introduction of INTRABEAM IORT. Disclosure. Contents. I have nothing to disclose.

Quality Assurance of a 50-kV Radiotherapy Unit Using EBT3 GafChromic Film: A Feasibility Study

Evaluation of a single-scan protocol for radiochromic film dosimetry

Intensity Modulated Radiation Therapy: Dosimetric Aspects & Commissioning Strategies

Brachytherapy Planning and Quality Assurance

Measurement of Dose to Implanted Cardiac Devices in Radiotherapy Patients

STEREOTACTIC DOSE VERIFICATION PHANTOM VERSATILE STEREOTACTIC QA PHANTOMS

Assessing Heterogeneity Correction Algorithms Using the Radiological Physics Center Anthropomorphic Thorax Phantom

GAFCHROMIC MD-55 RADIOCHROMIC DOSIMETRY FILM FOR HIGH-ENERGY PHOTONS CONFIGURATION, SPECIFICATIONS AND PERFORMANCE DATA

TLD as a tool for remote verification of output for radiotherapy beams: 25 years of experience

A REANALYSIS OF THE COLLABORATIVE OCULAR MELANOMA STUDY MEDIUM TUMOR TRIAL EYE PLAQUE DOSIMETRY

Calibration of two 90 Sr+ 90 Y dermatological applicators

Dosimetry comparison of orthovoltage x-ray and 137 Cs irradiation of the murine bone marrow compartment Matthew Belley

Accuracy Requirements and Uncertainty Considerations in Radiation Therapy

Implantable MOSFET dosimeter response to 192 Ir HDR radiation

Commissioning and Radiobiology of the INTRABEAM System

Small Field Dosimetry & Radiochromic film

Eye plaque dosimetry verification using novel solid state devices

Comparison of dosimetry parameters of two commercially available Iodine brachytherapy seeds using Monte Carlo calculations

Two-Dimensional Thermoluminescence Dosimetry System for Proton Beam Quality Assurance

Online in vivo dosimetry in conformal radiotherapies with MOSkin detectors

Method for verifying the air kerma strength of I-125 plaques for the treatment of ocular melanoma

Quality Assurance of TPS: comparison of dose calculation for stereotactic patients in Eclipse and iplan RT Dose

Three-dimensional dosimetry imaging of I-125 plaque for eye cancer treatment

Evaluation of triple channel correction acquisition method for radiochromic film dosimetry

An anthropomorphic head phantom with a BANG polymer gel insert for dosimetric evaluation of IMRT treatment delivery

Protons Monte Carlo water-equivalence study of two PRESAGE formulations for proton beam dosimetry J. Phys.: Conf. Ser.

EORTC Member Facility Questionnaire

Multilayer Gafchromic film detectors for breast skin dose determination in vivo

Implementing New Technologies for Stereotactic Radiosurgery and Stereotactic Body Radiation Therapy

Dosimetric Characterization of a Prototype Nanotechnology Microbeam Radiation Therapy Device using Gafchromic EBT2 Film

8/2/2017. Objectives. Disclosures. Clinical Implementation of an MR-Guided Treatment Unit

Verification of treatment planning system parameters in tomotherapy using EBT Radiochromic Film

Measurements of Air Kerma Index in Computed Tomography: A comparison among methodologies

ADVANCED TECHNOLOGY CONSORTIUM (ATC) CREDENTIALING PROCEDURES FOR LUNG BRACHYTHERAPY IMPLANT PROTOCOLS

Evaluation and implementation of triple-channel radiochromic film dosimetry in brachytherapy

Gafchromic film dosimetry of a new HDR 192 Ir brachytherapy source

Leila E. A. Nichol Royal Surrey County Hospital

Monte Carlo and experimental relative dose determination for an Iridium-192 source in water phantom

A novel phantom design for brachytherapy quality assurance

Factory loaded, sterilized, ready to implant plaques:!

Eric E. Klein, Ph.D. Chair of TG-142

Sang Hun Shin, Wook Jae Yoo, Kyoung Won Jang, Seunghyun Cho, 1 Kum Bae Kim, 2 and Bongsoo Lee 3*

Calibration of dosimeters for small mega voltage photon fields at ARPANSA

Activity report from JCOG physics group

Comparison and uncertainty evaluation of different calibration protocols and ionization chambers for low-energy surface brachytherapy dosimetry

Mania Aspradakis John Byrne Hugo Palmans John Conway Jim Warrington Karen Rosser Simon Duane

ABSTRACTS FOR RADIOTHERAPY STANDARDS USERS MEETING. 5 th June 2007

Accurate Accurate boost or Simply Accuboost

Can we deliver the dose distribution we plan in HDR-Brachytherapy of Prostate Cancer?

Process Control Methods in Radiation Technologies

NEW PERFORMANCE STANDARD: GAFCHROMIC FILM BASED DOSIMETRY SYSTEM. Xiang Yu and Andre Micke Advanced Materials Group Ashland Specialty Ingredients

Limits of Precision and Accuracy of Radiation Delivery Systems

Standardization of dosimetry practices for small and large animal irradiation in radiobiological studies

Quality assurance in external radiotherapy

Seed coordinates of a new COMS-like 24 mm plaque verified using the FARO Edge

Semiflex 3D. Always perfectly oriented. 3D Thimble Ionization Chamber for Relative and Absolute Dosimetry

2018 Council on Ionizing Radiation Measurements and Standards. Low Energy ( kev) Electron Beam Calibration. Gary Pageau

Developing a Verification and Training Phantom for Gynecological Brachytherapy System

Evaluation of Dosimetric Characteristics of a Double-focused Dynamic Micro-Multileaf Collimator (DMLC)

Verification of relative output factor measurement using Gafchromic films for small-field radiosurgery photon beams.

The need for standardization of dosimetry in experimental radiation biology

Dosimetric characterization with 62 MeV protons of a silicon segmented detector for 2D dose verifications in radiotherapy

Dosimetry benchmark for MBDCA

ph fax

Lung Spine Phantom. Guidelines for Planning and Irradiating the IROC Spine Phantom. MARCH 2014

Non-target dose from radiotherapy: Magnitude, Evaluation, and Impact. Stephen F. Kry, Ph.D., D.ABR.

UNCERTAINTIES REPORTING IN MEDICAL PHYSICS. Jing Cui, DSc. Assistant Professor Department of Radiation Oncology UC Davis Comprehensive Cancer Center

Gafchromic EBT-XD film: Dosimetry characterization in high-dose, volumetric-modulated arc therapy

Transcription:

SAM Practical Medical Physics Session: TU-F-201 Radiochromic Film Dosimetry Update Tuesday, July 14, 2015, 2:45 pm 3:45 pm Applications in brachytherapy Samuel Trichter, M.Sc., Department of Radiation Oncology, New York-Presbyterian Hospital, Weill Cornell Medical Center, New York, NY 1

Historically radiochromic film was used mostly in brachytherapy, since: Radiochromic film was available only in small sheets (5 x5 ) Required 30 (MD55) 100 Gy (HD810 and earlier) in order to produce an useful exposure Was non-uniform as much as 15% across the sheets. Could be tolerated at acceptable in brachytherapy uncertainty levels Could be handled at light (except for sunlight) and marked using marker pens Did not require processing Is thin and could be easily bent and sandwiched in phantoms. Could be used in water. Has very high spatial resolution in the submillimeter range, good for high dose gradient areas 2 2

Radiochromic film: Is nearly tissue equivalent New EBT films are significantly more sensitive (2 Gy per exposure vs. 30 Gy for MD-55 or 100 Gy for HD-810) New EBT films have uniformity similar to radiographic film New EBT films have less energy dependent dose response Has to be used in accordance with a strict protocol due to postexposure growth of optical density Has to be always scanned in the same direction due to polarization effects Has to be pre-cut at least 48 hours prior to exposure in order to equilibrate moisture content 3 3

Main brachytherapy applications Dosimetry and calibration of 90 Sr/ 90 Y ophthalmic applicators Dosimetry and calibration of 106 Ru/ 106 Rh eye plaques Dosimetry of 125 I eye plaques Dosimetry and characterization of 125 I and 131 Cs brachytherapy seeds Electronic brachytherapy calibration and dosimetry Dosimetry of liquid 125 I GliaSite 192 Ir dosimetry HDR machine QA QA of HDR applicators and plans 4 4

GAFCHROMIC EBT film configurations CLEAR POLYESTER - 97 microns ACTIVE LAYER - 17 microns SURFACE LAYER - 6 microns ACTIVE LAYER - 17 microns SURFACE LAYER - 3 microns ACTIVE LAYER - 17 microns CLEAR POLYESTER - 97 microns CLEAR POLYESTER - 97 microns Standard double layer EBT Special single layer EBT-1 EBT2 and EBT3 films available in thin unprotected single layer configuration 5 5

Example of radiochromic film eye plaque dosimetry Includes all elements of radiochromic film brachytherapy dosimetry. (From Chiu-Tsao, AAPM 1994 Summer School) New cases per year in the US: Choroidal melanoma 1500 Retinoblastoma 600 Choroidal melanoma 6 6

106 Ru eye plaques 106 Ru is a beta emitter, 3.54 MeV maximum energy, 373.6 days half-life The CCX type is only 11.6 mm in diameter and 2.2 mm in height 7 7

COMS Plaques silastic inserts assembled plaques without seeds gold backings 125 I seeds 27-35 KeV photons 59.43 days half-life (From Chiu-Tsao, AAPM 1994 Summer School) 8 8

Solid Water Eye phantom configured for a CCX 106 Ru eye plaque with an irradiated MD-55- film 9 9

Solid Water Eye phantom configured for a 20 mm COMS eye plaque with a fully loaded eye plaque 10 10

Solid Water Eye phantom with a 20 mm COMS eye plaque assembled for measurement. For measurements the Eye phantom is inserted into a full scatter 30 cm x 30 cm x 30 cm Solid Water phantom 11 11

Punches for precise cutting of film 12 12

Exposed special single layer EBT-1 films 13 13

CCX-129 eye plaque dosimetry using special single layer EBT-1 film 1000.0 900.0 Dose rate (cgy/hour) 800.0 700.0 600.0 500.0 400.0 300.0 EBT film EBT film fit BEBIG BEBIG fit 200.0 100.0 0.0 0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 Distance from inner surface (mm) Figure 3. Measured dose rate along the central axis of the CCX 129 plaque compared to the data provided by BEBIG. Dose rate along the central axis of the plaque Isodose distribution perpendicular to the central axis at distance 2.642 mm from the plaque s inner surface The dose rate at the surface of the eye plaque is actually measured 14 14

Calibration of radiochromic film Calibration films should be preferably irradiated in the same conditions as the unknown films water equivalent plastic (Solid Water, Polystyrene) or liquid water Calibration films should be irradiated to preferably same radiation quality and dose rate as expected dosimetric measurements. These can be large uniform linac and 60 Co beams, brachytherapy sources like 90 Sr or 125 I. The calibration beams and sources should be well characterized with traceability to NIST (ADCL calibrated beams are traceable to NIST). Small films precut in advance should be used in brachytherapy. 15 15

Calibration of radiochromic film There should be enough dose points to cover more than the expected measurement range. Extrapolating calibration curves is dangerous. The final curve can be fitted to an analytical expression and smoothed. It is recommended to test the calibration curve irradiating and evaluating known fields. 16 16

EBT-1 Lot 35314-4H Energy Dependence 60000 55000 6 MeV electrons calibration I-125 calibration 50000 45000 Pixel value 40000 35000 30000 25000 20000 0 100 200 300 400 500 600 700 800 900 1000 1100 Dose (cgy) The films were calibrated for 125 I using a calibrated model 6711 125 I seed in the eye phantom 17 17

Corrections: Absorbed-Dose Energy Dependence calculations for the 2009 AAPM Summer School textbook (D. Rogers) 18 18

Monte Carlo corrections The measured absorbed dose is usually dose to film in solid water equivalent phantom The quantity of interest is absorbed dose to liquid water It is important to know exact chemical composition of the phantom material and of the film used The calcium content in Gammex RMI 457 Solid Water can be either 1.7% or 2.3% Can result in 5% or 9% conversion factor difference from Solid Water to liquid water for 125 I or 103 Pd seeds respectively Updated Solid Water to water conversion factors for 125 I and 103 Pd brachytherapy sources Ali S. Meigooni, Shahid B. Awan, Nathan S. Thompson, and Sharifeh A. Dini Med. Phys. 33 (11), November 2006 Including the film in the calculations has additional effect on the conversion factors 19 19

Conclusions Radiochromic film in a Solid Water phantom is a convenient, accurate, and reproducible dosimeter for brachytherapy dosimetry Properly calibrated radiochromic film can be used for absolute brachytherapy dosimetry A calibrated 125 I seed and the TG-43 formalism can be used for calibrating radiochromic film for absolute dosimetry The special single layer films enable direct dose measurements virtually at the surface of brachytherapy sources and applicators Monte Carlo simulations enable conversion of dose to film in a solid phantom to dose to liquid water 20 20

Reference List 1. Sayeg JA, Gregory RC. A new method for characterizing beta-ray ophthalmic applicator sources. Med Phys 1991;18:453-461. 2. Soares CG. Calibration of ophthalmic applicators at NIST: A revised approach. Med Phys 1991;18:787-793. 3. Soares CG. A method for the calibration of concave 90 Sr+ 90 Y ophthalmic applicators. Phys Med Biol 1992;37:1005-1007. 4. Soares CG, Vynckier S, Järvinen H, et al. Dosimetry of beta-ray ophthalmic applicators: Comparison of different measurement methods. Med Phys 2001;28:1373-1384. 5. Taccini G, Cavagnetto F, Coscia G, et al. The determination of dose characteristics of ruthenium ophthalmic applicators using radiochromic film. Med Phys 1997;24:2034-2037. 6. Trichter S, Amols H, Cohen G, et al. Accurate dosimetry of Ru-106 ophthalmic applicators using GafChromic film in a Solid Water phantom. Med Phys 2002;29:1349. 7. Trichter S, Zaider M, Nori D, et al. Clinical dosimetry of 106 Ru eye plaques in accordance with the forthcoming ISO Beta Dosimetry Standard using specially designed GAFCHROMIC film. Int J Radiation Oncology Biol Phys 2007;69:S665-S666. 8. ISO International Standard: Clinical dosimetry - beta radiation sources for brachytherapy. International Organization for Standardization; 2009. Report No.: 21439:2009. 9. Stevens MA, Turner JR, Hugtenburg RP, et al. High-resolution dosimetry using radiochromic film and a document scanner. Phys Med Biol 1996;41:2357-2365. 10. Trichter S, Zaider M, Munro J, et al. Accurate dosimetric characterization of a novel 125 I eye plaque design. Med Phys 2008;35:2632. 11. Trichter S, Chiu-Tsao S-T, Zaider M, et al. Accurate dosimetric characterization of a fully loaded 20 mm COMS I-125 eye plaque using specially designed GAFCHROMIC film. Med Phys 2011;38:3791. 12. Acar H, Chiu-Tsao S-T, Özbay I, et al. Evaluation of material heterogeneity dosimetric effects using radiochromic film for COMS eye plaques loaded with 125 I seeds (model I25.S16). Med Phys 2013;40:011708-1-011708-13.

13. Poder J, Corde S. I-125 ROPES eye plaque dosimetry: Validation of a commercial 3D ophthalmic brachytherapy treatment planning system and independent dose calculation software with GafChromic EBT3 films. Med Phys 2013;40:121709-1- 121709-11. 14. Chiu-Tsao S-T, de la Zerda A, Lin J, et al. High-sensitivity GafChromic film dosimetry for 125 I seed. Med Phys 1994;21:651-657. 15. Chiu-Tsao S-T, Hanley J, Napoli J, et al. Determination of TG43 parameters for Cs- 131 model CS-1R2 seed using radiochromic EBT film dosimetry. Med Phys 2007;34:2434-2435. 16. Chiu-Tsao S-T, Medich D, Munro III J. The use of new GAFCHROMIC EBT film for 125 I seed dosimetry in Solid Water phantom. Med Phys 2008;35:3787-3799. 17. Morrison H, Menon G, Sloboda RS. Radiochromic film calibration for low-energy seed brachytherapy dose measurement. Med Phys 2014;41:072101-1-072101-11. 18. Schneider F, Fuchs H, Lorenz F, et al. A novel device for intravaginal electronic brachytherapy. Int J Radiation Oncology Biol Phys 2009;74:1298-1305. 19. Eaton DJ, Duck S. Dosimetry measurements with an intra-operative x-ray device. Phys Med Biol 2010;55:N359-N369. 20. Eaton DJ. Quality assurance and independent dosimetry for an intraoperative x-ray device. Med Phys 2012;39:6908-6920. 21. Avanzo M, Rink A, Dassie A, et al. In vivo dosimetry with radiochromic films in low-voltage intraoperative radiotherapy of the breast. Med Phys 2012;39:2359-2368. 22. Liu Q, Schneider F, Ma L, et al. Relative biologic effectiveness (RBE) of 50 kv x- rays measured in a phantom for intraoperative tumor-bed irradiation. Int J Radiation Oncology Biol Phys 2013;85:1127-1133. 23. Nwankwo O, Clausen S, Schneider F, et al. A virtual source model of a kilo-voltage radiotherapy device. Phys Med Biol 2013;58:2363-2375. 24. Hill R, Healy B, Holloway L, et al. Advances in kilovoltage x-ray beam dosimetry. Phys Med Biol 2014;59:R183-R231. 25. Monroe JI, Dempsey JF, Dorton JA, et al. Experimental validation of dose calculation algorithms for the GliaSite RTS, a Novel 125 I liquid-filled balloon brachytherapy applicator. Med Phys 2001;28:73-85. 26. Chiu-Tsao S-T, Duckworth TL, Patel NS, et al. Verification of Ir-192 near source dosimetry using GAFCHROMIC film. Med Phys 2004;31:201-207.

27. Aldelaijan S, Mohammed H, Tomic N, et al. Radiochromic film dosimetry of HDR 192 Ir source radiation fields. Med Phys 2011;38:6074-6083. 28. Chiu-Tsao S-T, Rusch TW, Axelrod S, Tsao H-S, Harrison L. Radiochromic film dosimetry for a new electronic brachytherapy source. Med Phys 2004;33:1913 29. Chiu-Tsao S-T, Davis S, Pike T, DeWerd L, Rusch T, Burnside R, Chadha M, Harrison LB. Two-dimensional Dosimetry for an Electronic Brachytherapy Source Using Radiochromic EBT Film: Determination of TG43 Parameters. Brachytherapy 2007;6:110